Pentair Swimming Pool Heater Pump User Manual

WhisperFloPump Owner's Manual  
IMPORTANT SAFETY INSTRUCTIONS  
READ AND FOLLOW ALL INSTRUCTIONS  
SAVE THESE INSTRUCTIONS  
Table of Contents  
SECTION I.  
SECTION II.  
GENERAL INFORMATION ............................................................................................ 2  
MAINTENANCE ......................................................................................................... 3  
SECTION III. SERVICE.................................................................................................................. 5  
SECTION IV. RESTART INSTRUCTIONS ........................................................................................... 6  
SECTION V.  
TROUBLESHOOTING ................................................................................................. 7  
SECTION VI. TECHNICAL DATA ...................................................................................................... 8  
A. REPLACEMENT PARTS ........................................................................................................ 8  
B. PUMP CURVES .................................................................................................................. . 9  
WARNING  
Before installing this product, read and follow all warning notices and instructions accompanying this pump.  
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call  
(800) 831-7133 for additional free copies of this manual.  
Important Notice  
Attention Installer.  
This manual contains important information about the installation, operation and safe use of this  
product. This information should be given to the owner/operator of this equipment.  
WARNING  
Risk of electrical shock or electrocution.  
This pool pump must be installed by a licensed or certified electrician or a qualified pool  
serviceman in accordance with the National Electrical Code and all applicable local codes and  
ordinances. Improper installation will create an electrical hazard which could result in death or  
serious injury to pool users, installers, or others due to electrical shock, and may also cause  
damage to property.  
Always disconnect power to the pool pump at the circuit breaker before servicing the pump.  
Failure to do so could result in death or serious injury to serviceman, pool users or others due to  
electric shock.  
Pentair Pool Products  
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151  
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400  
Listed  
227T  
Listed  
Rev. D 6-5-01  
1
P/N 071109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Permanently ground the motor using the green ground terminal  
located on the inside of the motor canopy or access plate, see  
Figure 1. Use the correct wire size and type specified by  
National Electrical Code. Make sure the ground wire is  
connected to an electrical service ground.  
Bonding Lug  
Ground Screw  
7. Bond the motor to the pool structure in accordance with the  
National Electrical Code. Use a solid No. 8 AWG or larger  
copper conductor. Run a wire from the external bonding to the  
pool bonding structure, see Figure 1.  
8. Connect the pump permanently to a circuit. Make sure no other  
lights or appliances are on the same circuit.  
Figure 1.  
NOTE  
It is important that the O-ring be kept clean and well lubricated. We recommend a silicone base lubricant for best results.  
B. The Pump Strainer Basket.  
Thisunit,sometimesreferredtoastheHairandLintPot’,istheunitinfrontofthevolute.Insidethechamberisthe  
basketwhichmustbekeptcleanofleavesanddebrisatalltimes.ViewbasketthroughtheSeeThroughLidtoinspect  
forleavesanddebris.  
Regardlessofthelengthoftimebetweenfiltercleaning,itismostimportanttovisuallyinspectthehairandlintpotbasket  
atleastonceaweek.Adirtybasketwillreducetheefficiencyofthefilterandheaterandalsoputanabnormalstresson  
thepumpmotorwhichwouldresultinacostlyrepairbill.  
SECTION II. MAINTENANCE.  
CAUTION  
To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer and skimmer  
baskets regularly.  
A. Pump Strainer Basket Cleaning Procedures.  
1. Turn off motor.  
2. Relieve pressure in the system.  
Clamp, pot  
3. Turn the clamp and lid in a counter-clockwise direction until it stops.  
4. Turn the clamp and lid set to remove the clamp and lid.  
Lid  
5. Put the debris from the basket into the trash and rinse out the basket. If  
the basket is cracked, it should be replaced.  
O-ring, lid  
6. Replace the basket and fill the pump pot and volute up to the inlet port  
with water.  
7. Clean the cover, cover O-ring, and sealing surface of the pump pot.  
Grease the O-ring with Teflon or silicone.  
Basket  
Pot  
8. Reinstall the lid by placing the clamp and the lid on the pot;  
see Figure 2.  
a. Make sure the lid O-ring is properly placed. Seat the clamp and lid  
then turn clockwise until the handles are horizontal; see Figure 3.  
9. Turn the power “ON” at the house circuit breaker. Reset the pool time  
clock to the correct time.  
Figure 2.  
Rev. D  
6-5-01  
3
P/N 071109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING  
SYSTEM (e.g., LOCK RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER  
THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO  
BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO  
AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.  
10. Open the High Flow™ manual air relief valve on top of the filter.  
11. Stand clear of the filter. Start the pump.  
12. Bleed air from the filter until a steady stream of water comes out.  
Clamp  
Lid  
Close the High Flow™ manual air relief valve.  
B. Winterizing.  
1. If the air temperature drops below 35° F. the water in the pump can  
freeze and cause damage. Freeze damage is not warrantable.  
2. To prevent freeze damage follow the procedures listed below.  
Volute  
a. Shut off electrical power for the pump at the house circuit breaker.  
b. Drain the water out of the pump case by removing the two thumb-  
Figure 3.  
twist drain plugs from the case. Store the plugs in the pump  
basket.  
c. Cover the motor to protect it from severe rain, snow and ice.  
d. Do not wrap the motor in plastic. It will cause condensation and rust on the inside of the motor.  
C. Care of Electric Motor.  
1. Protect from heat.  
a. Shade the motor from the sun.  
b. Any enclosure must be well ventilated to prevent overheating.  
c. Provide ample cross ventilation.  
2. Protect against dirt.  
a. Protect from any foreign matter or splashing water.  
b. Do not store (or spill) pool chemicals near the motor.  
c. Avoid sweeping or stirring up dust near the motor while it is operating.  
d. If a motor has been damaged by dirt it voids the motor warranty.  
3. Protect against moisture.  
a. Protect from splashing pool water.  
b. Protect from the weather.  
c. Protect from lawn sprinklers.  
d. If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has  
been flooded.  
e. If a motor has been damaged by water it voids the motor warranty.  
NOTE  
DO NOT wrap motor with plastic or other air tight materials. The motor may be covered during a storm, for winter  
storage, etc., but never when operating, or expecting operation.  
NOTE  
When replacing the motor, be certain that the motor support is correctly positioned to support the size of motor being  
installed.  
P/N 071109  
4
Rev. D  
6-5-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION III. SERVICE.  
WARNING  
Risk of electrical shock or electrocution.  
This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in  
accordance with the National Electrical Code and all applicable local codes and ordinances. Improper  
installation will create an electrical hazard which could result in death or serious injury to pool users,  
installers, or others due to electrical shock, and may also cause damage to property.  
Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do  
so could result in death or serious injury to serviceman, pool users or others due to electric shock.  
Read all servicing instructions before working on the pump.  
A. Pump Disassembly.  
1. All moving parts are located in the rear sub-assembly of this pump.  
Toolsrequired:  
a. 3/32 inch Allen head wrench.  
b. ½ inch open end wrench.  
c. 9/16 inch open end wrench.  
d. Flatbladescrewdriver.  
2. To remove and repair the motor sub-assembly perform the following procedures.  
a. Turn off the pump circuit breaker at the main panel.  
b. Drain the pump by removing the drain plugs.  
c. Remove the 6 bolts that hold the main pump body (strainer pot/volute) to the rear sub-assembly.  
d. GENTLY pull the two pump halves apart, removing the rear sub-assembly.  
e. Use a 3/32 inch Allen head wrench to loosen the two holding screws located on the diffuser.  
CAUTION  
Be sure not to scratch or mar the polished shaft seal faces; seal will leak if faces are damaged.  
f. Hold the impeller securely in place and remove the impeller lock screw by using a flat blade  
screwdriver. The screw is a left-handed thread and loosens in a clockwise direction.  
g. Remove the shaft cap located at the back of the motor and hold the shaft secure with a ½ inch  
(Century) or 7/16 inch (Franklin) open-end wrench. On A. 0. Smith motors, remove the motor  
canopy, move the capacitor to one side and hold the shaft with a 7/16 inch open-end wrench.  
h. To unscrew the impeller from the shaft, twist the impeller counterclock- wise.  
i. Remove the four bolts from the seal plate to the motor, using a 9/16 inch wrench.  
j. Place the seal plate face down on a flat surface and tap out the carbon/spring seat.  
k. Clean the seal plate, seal housing, and the motor shaft.  
Rev. D  
6-5-01  
5
P/N 071109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Pump Reassembly/Seal Replacement; see Section V, Technical  
Data, Figure 4.  
Bolt  
1. When installing the replacement shaft seal, use silicone  
sealant on the metal portion, before pressing into the seal  
plate.  
2. Before installing the ceramic section of the seal into the  
impeller, be sure the impeller is clean. Use a light density  
soap and water to seal the seal. Press the seal into the  
impeller with your thumbs and wipe off the ceramic and  
carbon faces with a clean cloth.  
Seal Plate  
Gasket  
Lockscrew  
Water Slinger  
Motor Shaft  
Impeller  
Lockscrew Seal  
3. Remount the seal plate to the motor.  
4. Grease the motor shaft thread and screw impeller onto the  
motor shaft.  
Figure 4.  
5. Screw in the impeller lock screw (counter-clockwise to tighten).  
6. Remount the diffuser onto the seal plate. Make sure the plastic pins and holding screw inserts are  
aligned.  
7. Grease the diffuser O-ring and seal plate gasket or O-ring prior to reassembly.  
8. Grease the bolt threads, assemble the motor sub-assembly to the strainer pot-pump body by using the  
two through bolts for proper alignment. Do not tighten the through bolts until all 6 bolts are in place and  
finger tightened.  
9. Fill the pump with water.  
10. Reinstall the pump lid and plastic clamp; see SECTION II. START-UP.  
11. Reprime the system.  
C. The Shaft Seal.  
1. The Shaft Seal consists primarily of two parts, a rotating member and a ceramic seal.  
2. The pump requires little or no service other than reasonable care, however, a Shaft Seal may  
occasionally become damaged and must be replaced.  
CAUTION  
The polished and lapped faces of the seal could be damaged if not handled with care.  
CAUTION  
In mild climate area, when temporary freezing conditions may occur, run your filtering equipment all night to prevent  
freezing.  
SECTION IV. RESTARTINSTRUCTIONS.  
A. If pump is installed below the water level of the pool, close return and suction lines prior to opening hair and  
lint pot on pump. Make sure to re-open valves prior to operating.  
CAUTION  
DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. If this  
occurs, the damaged seal must be replaced. ALWAYS maintain proper water level in your pool (half way up skimmer opening). If  
the water level falls below the skimmer opening, the pump will draw air through the skimmer, losing the prime and causing the  
pump to run dry, resulting in a damaged seal.  
Note  
Continued operation in this manner could cause a loss of pressure, resulting in damage to the pump case, impeller and seal.  
P/N 071109  
6
Rev. D  
6-5-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Priming the Pump.  
1. The pump strainer pot must be filled with water before the pump is initially started. Follow these steps to  
prime the pump.  
a. Remove the pump lid plastic clamp. Remove the pump lid.  
b. Fill the pump strainer pot with water.  
c. Reassemble the pump cover and plastic clamp onto the strainer pot. The pump is now ready to  
prime.  
d. Open the air release valve on the filter, and stand clear of the filter.  
e. Turn on the switch or time clock.  
f. When water comes out of the air release valve, close the valve. The system should now be free of air  
and recirculating water to and from the pool.  
2. For 2-speed pumps:  
a. Pump should run on high-speed for priming.  
b. The pump should not run longer than 8 minutes before priming is achieved.  
SECTION V. TROUBLESHOOTING.  
A. Failure to Pump.  
1. Pump will not prime - too much air. - Remedy:  
a. Check suction piping and valve glands on any suction gate valves.  
b. Secure lid on pump strainer pot and make sure lid gasket is in place.  
c. Check water level to make sure skimmer is not drawing air.  
2. Pump will not prime--not enough water. - Remedy:  
a. Make sure suction lines, pump strainer, and pump volute are full of water.  
b. Make sure valve on suction line is working and open, (some systems do not have valves).  
c. Check water level to make sure water is available through skimmer.  
3. Pump strainer clogged. - Remedy:  
a. Clean pump strainer pot.  
4. Pump strainer gasket defective. - Remedy:  
a. Replace gasket.  
B. Reduced Capacity and/or Head.  
1. Air pockets or leaks in suction line. - Remedy:  
a. See item A.1. of this section, above.  
2. Clogged impeller. Remedy:  
a. Turn off electrical power to the pump.  
b. Remove the clamp that holds the volute to the seal plate.  
c. Slide the motor and seal plate away from the volute.  
d. Clean debris from impeller. If debris cannot be removed, complete the following steps.  
(1) Remove left hand thread anti-spin bolt and O-ring.  
(2) Remove, clean and reinstall impeller.  
(3) Reinstall anti-spin bolt and O-ring.  
e. Reinstall wear-ring, diffuser, and O-ring.  
f. Reinstall motor and seal plate into volute aligning with keyway at top of volute.  
g. Reinstall clamp around seal plate and volute and tighten securely.  
3. Pump strainer clogged. - Remedy:  
a. Clean suction trap.  
Rev. D  
6-5-01  
7
P/N 071109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION VI. TECHNICALDATA.  
26  
28  
27  
A. Replacement Parts.  
Item  
No.  
Part  
No.  
Model  
No.  
Description  
Item  
No.  
Part  
No.  
Model  
No.  
Description  
1
1
357150  
357199  
07-0795  
357151  
350013  
07-0387  
07-0430  
07-2184  
07-0431  
07-1403  
357102  
350015  
357157  
07-1444  
07-1660  
07-2928  
07-2927  
07-1652  
07-5713  
07-1734  
07-1728  
07-0429  
CLAMP POT (Black)  
20  
20a  
21  
07-0929  
357160  
07-1657  
07-1406  
07-2183  
07-1131  
357161  
07-4629  
P10313  
FOOT INSERT WFE PUMP  
CLAMP POT (Almond)  
FOOT INSERT (CANADA ONLY)  
SCREW ¼ - 20 X 1 in. HH s/s, 2 req.  
NUT ¼ - 20 HEX. hd. s/s, 2 req.  
Wsh. FLAT ¼ X 5/8 , 2 req.  
2
P08080  
COVER LEXAN AQ/WFE PUMP  
COVER LEXAN WFE PUMP  
O-RING WFE COVER  
P26948  
P23802  
P35010  
P19656  
2
22  
3
23  
4
P01325  
P02812  
P35011  
P02813  
P23696  
BASKET AQ & WFE  
24  
KNOB PLUG DRAIN, 2 req.  
5
BOLT 3/8 16 X 1.15 HEX HD s/s, 4 req.  
Wsh. 3/8 s/s X 13/16 O.D. 6  
24a  
25  
KNOB, DRAIN (CANADA ONLY)  
GASKET, FLAT Wsh. WFE PMP. DRN., 2 req.  
ITEM 26, MOTORS  
6
7
BOLT 3/8 - 16 X 1/75 HX HD s/s, 2 req.  
NUT 3/8 - 16 HEX. hd., 2 req.  
GASKET SEAL PLATE WFE PUMP  
VOLUTE WFE PUMP & POT  
VOLUTE (CSA/CUL ONLY) CANADA  
O-RING PARKER #2-238 WFE PUMP  
SET SCREW #4-40 X 1-1/8 WFE, 2 req.  
DIFFUSER assy. WFE 12/3 HP ONLY  
DIFFUSER assy. WFE-3 & 8, 75 HP – 2.5 HP  
SET SCREW .25 20 X 1 LH PHILLIPS  
WFE PUMP RUBBER Wsh.  
8
26  
07-1313  
07-1314  
07-1315  
07-1316  
P21258  
P21259  
P21260  
P21261  
.75 HP 60HZ /WFE-2, 3 & 24, 29 Lbs.  
1 HP 60HZ /WFE-4 & 26, 33 Lbs.  
1.5 HP 60HZ /WFE-6 & 28, 39 Lbs.  
2 HP 60HZ /WFE-8 & 30, 40 Lbs.  
IMPELLER (SEE CHART)  
9
10  
10a  
11  
12  
13  
P24262  
P26951  
S05633  
S05632  
P26942  
27  
28  
357149  
VOLUTE REPLACEMENT KIT  
27 IMPELLER CHART  
14  
15  
STD  
PART NO.  
CANADIAN  
CSA/CUL  
HP  
SIZE  
16  
P28323  
SEAL PA-7 W/CERAMIC SEAT  
SEAL A7 s/s PS201 (CSA/CUL)  
BOLT 3/8-16 X 7/8 s/s HEX hd., 4 req.  
SEAL PLATE WFE - NOT AVAILABLE  
SEAL PLATE WFE  
16a  
17  
½
¾
1
WF, WFE-2, -23  
WF, WFE-3, -24  
WF, WFE-4, -26  
WF, WFE-6, -28  
WF, WFE-8, -30  
WFE-12  
073126  
073127  
073128  
073129  
073130  
073131  
357167  
357168  
357169  
357170  
357171  
357172  
P02811  
07-3742  
07-4564  
18  
1½  
2
357173  
07-0927  
357159  
SEAL PLATE / CUP (CSA/CUL)  
FOOT WFE - 4 PUMP  
19  
P10311  
19a  
FOOT (CANADA ONLY)  
3
P/N 071109  
8
Rev. D  
6-5-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Pump Curves.  
Single Speed Models  
Dual Speed Models  
SAVE THESE INSTRUCTIONS.  
Rev. D  
6-5-01  
9
P/N 071109  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pentair Pool Products WhisperFlo™  
Circulating Pump Limited Warranty  
Pentair Pool Products manufactures its WhisperFlo circulating  
Pentair Pool Products is not, however responsible under  
this warranty for any cost of shipping or transportation of  
the filter or part thereof to or from the service department.  
Also, Pentair Pool Products is not liable for any loss of time,  
inconvenience, incidental expenses such as telephone calls,  
labor or material charges incurred in connection with the  
removal or replacement of the equipment, or any other  
incidentalorconsequentialdamages.PLEASENOTE:Some  
states do not allow the exclusion or limitation or incidental  
or consequential damages, so the above limitation or  
exclusion may not apply to you.  
pumps under high standards of workmanship and with high  
quality materials. Accordingly, Pentair Pool Products expressly  
warrants those pump models as follows:  
WARRANTYCOVERAGE-Allpumpcomponentparts  
actually manufactured by Pentair Pool Products, and the  
pump’s respective motor is warranted to be free from defects in  
material and/or workmanship for a period of three (3) years from  
date of purchase. The obligation of Pentair Pool Products  
under this warranty will be limited to either repair or  
replacement of the product, at Pentair Pool Products option.  
PROCEDUREFOROBTAININGPERFORMANCE:Inorder  
to obtain the benefits of this warranty the consumer who  
made the original retail purchase will contact Pentair Pool  
Products Customer Service Department, 10951 W. Los  
Angeles Ave., Moorpark, CA 93021 as soon as possible  
after discovery of the defect, but in no event later than the  
expiration date of the warranty period provided in this  
warranty. Upon receipt of this communication, Pentair Pool  
Products will promptly notify the customer of the address to  
which the defective item may be shipped. The customer  
shall then ship the item, freight prepaid, to the address  
indicated together with a letter stating the model number,  
serial number, and the date of purchase of the item which is  
claimed to be defective, and the name and address of the  
consumer and a brief description of the problems  
encountered.  
EXCLUSIONSFROMTHISWARRANTY-Thiswarrantydoes  
not cover:  
1. Any item manufactured by other companies and installed  
by Pentair Pool Products. Such items may carry warranties  
offered by the original manufacturer.  
2. Problems resulting from oversizing of pump and/or  
reduction of valve piping size, or from failure to turn pump  
off before changing the position of the filter valve or any  
operating valves for the pool and its accessories.  
3. Problems resulting from failure to comply with instructions  
contained in the Owner's Manual.  
4. Problems resulting from abuse, misuse, negligence or  
accident by any party other than Pentair Pool Products,  
such as but not limited to, damage to parts caused by  
installers, damage to pump parts caused by ‘dry’ operation  
(loss of prime or obstruction in plumbing lines).  
WARRANTYPROTECTSORIGINALPURCHASER:This  
warranty extends to the consumer who made the original  
retail purchase only and is not enforceable by any other  
party.  
5. Problems resulting in whole or in part from alteration or  
modification of the filter by any party.  
6. Failures due to chemical corrosion caused by failure to  
maintain the water chemistry in conformity with the  
standard of the swimming pool and spa industry.  
WARRANTIESORREPRESENTATIONSBYOTHERS:No  
dealer or other person has any authority to make any  
warranties or representations concerning Pentair Pool  
Products or its products. Accordingly, Pentair Pool  
Products is not responsible for any such warranties or  
representations.  
WARRANTYOBLIGATIONSOFPENTAIRPOOL  
PRODUCTS-Shouldadefectinworkmanshipand/ormaterial  
in any item covered by this warranty become evident during  
the term of the warranty, then upon the consumer following the  
procedures set forth below, Pentair Pool Products will, at its  
option, repair or replace such item or part at its own cost and  
expense.  
OTHERRIGHTS:Thiswarrantygivesyouspecificlegal  
rights and you may also have other rights which vary from  
state to state.  
Pentair Pool Products  
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151  
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400  
P/N 071109  
1 0  
Rev. D  
6-5-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pelco Home Security System C2410M 1 User Manual
Perlick Refrigerator CS1DPSP User Manual
Philips TV Mount SQM5312 User Manual
Pioneer Stereo Amplifier SX A9MK2 K User Manual
Planar Crib Toy PD7130 User Manual
Plantronics Bluetooth Headset 640E User Manual
Plantronics Headphones H141 User Manual
Polaris Offroad Vehicle 600 Fusion User Manual
Poulan Snow Blower 414659 User Manual
Powermate Portable Generator PC049650317 User Manual