WhisperFlo™ Pump Owner's Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Table of Contents
SECTION I.
SECTION II.
GENERAL INFORMATION ............................................................................................ 2
MAINTENANCE ......................................................................................................... 3
SECTION III. SERVICE.................................................................................................................. 5
SECTION IV. RESTART INSTRUCTIONS ........................................................................................... 6
SECTION V.
TROUBLESHOOTING ................................................................................................. 7
SECTION VI. TECHNICAL DATA ...................................................................................................... 8
A. REPLACEMENT PARTS ........................................................................................................ 8
B. PUMP CURVES .................................................................................................................. . 9
WARNING
Before installing this product, read and follow all warning notices and instructions accompanying this pump.
Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call
(800) 831-7133 for additional free copies of this manual.
Important Notice
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
WARNING
Risk of electrical shock or electrocution.
This pool pump must be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code and all applicable local codes and
ordinances. Improper installation will create an electrical hazard which could result in death or
serious injury to pool users, installers, or others due to electrical shock, and may also cause
damage to property.
Always disconnect power to the pool pump at the circuit breaker before servicing the pump.
Failure to do so could result in death or serious injury to serviceman, pool users or others due to
electric shock.
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400
Listed
227T
Listed
Rev. D 6-5-01
1
P/N 071109
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Permanently ground the motor using the green ground terminal
located on the inside of the motor canopy or access plate, see
Figure 1. Use the correct wire size and type specified by
National Electrical Code. Make sure the ground wire is
connected to an electrical service ground.
Bonding Lug
Ground Screw
7. Bond the motor to the pool structure in accordance with the
National Electrical Code. Use a solid No. 8 AWG or larger
copper conductor. Run a wire from the external bonding to the
pool bonding structure, see Figure 1.
8. Connect the pump permanently to a circuit. Make sure no other
lights or appliances are on the same circuit.
Figure 1.
NOTE
It is important that the O-ring be kept clean and well lubricated. We recommend a silicone base lubricant for best results.
B. The Pump Strainer Basket.
Thisunit,sometimesreferredtoasthe‘HairandLintPot’,istheunitinfrontofthevolute.Insidethechamberisthe
basketwhichmustbekeptcleanofleavesanddebrisatalltimes.Viewbasketthroughthe‘SeeThroughLid’toinspect
forleavesanddebris.
Regardlessofthelengthoftimebetweenfiltercleaning,itismostimportanttovisuallyinspectthehairandlintpotbasket
atleastonceaweek.Adirtybasketwillreducetheefficiencyofthefilterandheaterandalsoputanabnormalstresson
thepumpmotorwhichwouldresultinacostlyrepairbill.
SECTION II. MAINTENANCE.
CAUTION
To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer and skimmer
baskets regularly.
A. Pump Strainer Basket Cleaning Procedures.
1. Turn off motor.
2. Relieve pressure in the system.
Clamp, pot
3. Turn the clamp and lid in a counter-clockwise direction until it stops.
4. Turn the clamp and lid set to remove the clamp and lid.
Lid
5. Put the debris from the basket into the trash and rinse out the basket. If
the basket is cracked, it should be replaced.
O-ring, lid
6. Replace the basket and fill the pump pot and volute up to the inlet port
with water.
7. Clean the cover, cover O-ring, and sealing surface of the pump pot.
Grease the O-ring with Teflon or silicone.
Basket
Pot
8. Reinstall the lid by placing the clamp and the lid on the pot;
see Figure 2.
a. Make sure the lid O-ring is properly placed. Seat the clamp and lid
then turn clockwise until the handles are horizontal; see Figure 3.
9. Turn the power “ON” at the house circuit breaker. Reset the pool time
clock to the correct time.
Figure 2.
Rev. D
6-5-01
3
P/N 071109
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING
SYSTEM (e.g., LOCK RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER
THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO
BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO
AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.
10. Open the High Flow™ manual air relief valve on top of the filter.
11. Stand clear of the filter. Start the pump.
12. Bleed air from the filter until a steady stream of water comes out.
Clamp
Lid
Close the High Flow™ manual air relief valve.
B. Winterizing.
1. If the air temperature drops below 35° F. the water in the pump can
freeze and cause damage. Freeze damage is not warrantable.
2. To prevent freeze damage follow the procedures listed below.
Volute
a. Shut off electrical power for the pump at the house circuit breaker.
b. Drain the water out of the pump case by removing the two thumb-
Figure 3.
twist drain plugs from the case. Store the plugs in the pump
basket.
c. Cover the motor to protect it from severe rain, snow and ice.
d. Do not wrap the motor in plastic. It will cause condensation and rust on the inside of the motor.
C. Care of Electric Motor.
1. Protect from heat.
a. Shade the motor from the sun.
b. Any enclosure must be well ventilated to prevent overheating.
c. Provide ample cross ventilation.
2. Protect against dirt.
a. Protect from any foreign matter or splashing water.
b. Do not store (or spill) pool chemicals near the motor.
c. Avoid sweeping or stirring up dust near the motor while it is operating.
d. If a motor has been damaged by dirt it voids the motor warranty.
3. Protect against moisture.
a. Protect from splashing pool water.
b. Protect from the weather.
c. Protect from lawn sprinklers.
d. If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has
been flooded.
e. If a motor has been damaged by water it voids the motor warranty.
NOTE
DO NOT wrap motor with plastic or other air tight materials. The motor may be covered during a storm, for winter
storage, etc., but never when operating, or expecting operation.
NOTE
When replacing the motor, be certain that the motor support is correctly positioned to support the size of motor being
installed.
P/N 071109
4
Rev. D
6-5-01
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION III. SERVICE.
WARNING
Risk of electrical shock or electrocution.
This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in
accordance with the National Electrical Code and all applicable local codes and ordinances. Improper
installation will create an electrical hazard which could result in death or serious injury to pool users,
installers, or others due to electrical shock, and may also cause damage to property.
Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do
so could result in death or serious injury to serviceman, pool users or others due to electric shock.
Read all servicing instructions before working on the pump.
A. Pump Disassembly.
1. All moving parts are located in the rear sub-assembly of this pump.
Toolsrequired:
a. 3/32 inch Allen head wrench.
b. ½ inch open end wrench.
c. 9/16 inch open end wrench.
d. Flatbladescrewdriver.
2. To remove and repair the motor sub-assembly perform the following procedures.
a. Turn off the pump circuit breaker at the main panel.
b. Drain the pump by removing the drain plugs.
c. Remove the 6 bolts that hold the main pump body (strainer pot/volute) to the rear sub-assembly.
d. GENTLY pull the two pump halves apart, removing the rear sub-assembly.
e. Use a 3/32 inch Allen head wrench to loosen the two holding screws located on the diffuser.
CAUTION
Be sure not to scratch or mar the polished shaft seal faces; seal will leak if faces are damaged.
f. Hold the impeller securely in place and remove the impeller lock screw by using a flat blade
screwdriver. The screw is a left-handed thread and loosens in a clockwise direction.
g. Remove the shaft cap located at the back of the motor and hold the shaft secure with a ½ inch
(Century) or 7/16 inch (Franklin) open-end wrench. On A. 0. Smith motors, remove the motor
canopy, move the capacitor to one side and hold the shaft with a 7/16 inch open-end wrench.
h. To unscrew the impeller from the shaft, twist the impeller counterclock- wise.
i. Remove the four bolts from the seal plate to the motor, using a 9/16 inch wrench.
j. Place the seal plate face down on a flat surface and tap out the carbon/spring seat.
k. Clean the seal plate, seal housing, and the motor shaft.
Rev. D
6-5-01
5
P/N 071109
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Pump Reassembly/Seal Replacement; see Section V, Technical
Data, Figure 4.
Bolt
1. When installing the replacement shaft seal, use silicone
sealant on the metal portion, before pressing into the seal
plate.
2. Before installing the ceramic section of the seal into the
impeller, be sure the impeller is clean. Use a light density
soap and water to seal the seal. Press the seal into the
impeller with your thumbs and wipe off the ceramic and
carbon faces with a clean cloth.
Seal Plate
Gasket
Lockscrew
Water Slinger
Motor Shaft
Impeller
Lockscrew Seal
3. Remount the seal plate to the motor.
4. Grease the motor shaft thread and screw impeller onto the
motor shaft.
Figure 4.
5. Screw in the impeller lock screw (counter-clockwise to tighten).
6. Remount the diffuser onto the seal plate. Make sure the plastic pins and holding screw inserts are
aligned.
7. Grease the diffuser O-ring and seal plate gasket or O-ring prior to reassembly.
8. Grease the bolt threads, assemble the motor sub-assembly to the strainer pot-pump body by using the
two through bolts for proper alignment. Do not tighten the through bolts until all 6 bolts are in place and
finger tightened.
9. Fill the pump with water.
10. Reinstall the pump lid and plastic clamp; see SECTION II. START-UP.
11. Reprime the system.
C. The Shaft Seal.
1. The Shaft Seal consists primarily of two parts, a rotating member and a ceramic seal.
2. The pump requires little or no service other than reasonable care, however, a Shaft Seal may
occasionally become damaged and must be replaced.
CAUTION
The polished and lapped faces of the seal could be damaged if not handled with care.
CAUTION
In mild climate area, when temporary freezing conditions may occur, run your filtering equipment all night to prevent
freezing.
SECTION IV. RESTARTINSTRUCTIONS.
A. If pump is installed below the water level of the pool, close return and suction lines prior to opening hair and
lint pot on pump. Make sure to re-open valves prior to operating.
CAUTION
DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. If this
occurs, the damaged seal must be replaced. ALWAYS maintain proper water level in your pool (half way up skimmer opening). If
the water level falls below the skimmer opening, the pump will draw air through the skimmer, losing the prime and causing the
pump to run dry, resulting in a damaged seal.
Note
Continued operation in this manner could cause a loss of pressure, resulting in damage to the pump case, impeller and seal.
P/N 071109
6
Rev. D
6-5-01
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Priming the Pump.
1. The pump strainer pot must be filled with water before the pump is initially started. Follow these steps to
prime the pump.
a. Remove the pump lid plastic clamp. Remove the pump lid.
b. Fill the pump strainer pot with water.
c. Reassemble the pump cover and plastic clamp onto the strainer pot. The pump is now ready to
prime.
d. Open the air release valve on the filter, and stand clear of the filter.
e. Turn on the switch or time clock.
f. When water comes out of the air release valve, close the valve. The system should now be free of air
and recirculating water to and from the pool.
2. For 2-speed pumps:
a. Pump should run on high-speed for priming.
b. The pump should not run longer than 8 minutes before priming is achieved.
SECTION V. TROUBLESHOOTING.
A. Failure to Pump.
1. Pump will not prime - too much air. - Remedy:
a. Check suction piping and valve glands on any suction gate valves.
b. Secure lid on pump strainer pot and make sure lid gasket is in place.
c. Check water level to make sure skimmer is not drawing air.
2. Pump will not prime--not enough water. - Remedy:
a. Make sure suction lines, pump strainer, and pump volute are full of water.
b. Make sure valve on suction line is working and open, (some systems do not have valves).
c. Check water level to make sure water is available through skimmer.
3. Pump strainer clogged. - Remedy:
a. Clean pump strainer pot.
4. Pump strainer gasket defective. - Remedy:
a. Replace gasket.
B. Reduced Capacity and/or Head.
1. Air pockets or leaks in suction line. - Remedy:
a. See item A.1. of this section, above.
2. Clogged impeller. Remedy:
a. Turn off electrical power to the pump.
b. Remove the clamp that holds the volute to the seal plate.
c. Slide the motor and seal plate away from the volute.
d. Clean debris from impeller. If debris cannot be removed, complete the following steps.
(1) Remove left hand thread anti-spin bolt and O-ring.
(2) Remove, clean and reinstall impeller.
(3) Reinstall anti-spin bolt and O-ring.
e. Reinstall wear-ring, diffuser, and O-ring.
f. Reinstall motor and seal plate into volute aligning with keyway at top of volute.
g. Reinstall clamp around seal plate and volute and tighten securely.
3. Pump strainer clogged. - Remedy:
a. Clean suction trap.
Rev. D
6-5-01
7
P/N 071109
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION VI. TECHNICALDATA.
26
28
27
A. Replacement Parts.
Item
No.
Part
No.
Model
No.
Description
Item
No.
Part
No.
Model
No.
Description
1
1
357150
357199
07-0795
357151
350013
07-0387
07-0430
07-2184
07-0431
07-1403
357102
350015
357157
07-1444
07-1660
07-2928
07-2927
07-1652
07-5713
07-1734
07-1728
07-0429
CLAMP POT (Black)
20
20a
21
07-0929
357160
07-1657
07-1406
07-2183
07-1131
357161
07-4629
P10313
FOOT INSERT WFE PUMP
CLAMP POT (Almond)
FOOT INSERT (CANADA ONLY)
SCREW ¼ - 20 X 1 in. HH s/s, 2 req.
NUT ¼ - 20 HEX. hd. s/s, 2 req.
Wsh. FLAT ¼ X 5/8 , 2 req.
2
P08080
COVER LEXAN AQ/WFE PUMP
COVER LEXAN WFE PUMP
O-RING WFE COVER
P26948
P23802
P35010
P19656
2
22
3
23
4
P01325
P02812
P35011
P02813
P23696
BASKET AQ & WFE
24
KNOB PLUG DRAIN, 2 req.
5
BOLT 3/8 16 X 1.15 HEX HD s/s, 4 req.
Wsh. 3/8 s/s X 13/16 O.D. 6
24a
25
KNOB, DRAIN (CANADA ONLY)
GASKET, FLAT Wsh. WFE PMP. DRN., 2 req.
ITEM 26, MOTORS
6
7
BOLT 3/8 - 16 X 1/75 HX HD s/s, 2 req.
NUT 3/8 - 16 HEX. hd., 2 req.
GASKET SEAL PLATE WFE PUMP
VOLUTE WFE PUMP & POT
VOLUTE (CSA/CUL ONLY) CANADA
O-RING PARKER #2-238 WFE PUMP
SET SCREW #4-40 X 1-1/8 WFE, 2 req.
DIFFUSER assy. WFE 12/3 HP ONLY
DIFFUSER assy. WFE-3 & 8, 75 HP – 2.5 HP
SET SCREW .25 20 X 1 LH PHILLIPS
WFE PUMP RUBBER Wsh.
8
26
07-1313
07-1314
07-1315
07-1316
P21258
P21259
P21260
P21261
.75 HP 60HZ /WFE-2, 3 & 24, 29 Lbs.
1 HP 60HZ /WFE-4 & 26, 33 Lbs.
1.5 HP 60HZ /WFE-6 & 28, 39 Lbs.
2 HP 60HZ /WFE-8 & 30, 40 Lbs.
IMPELLER (SEE CHART)
9
10
10a
11
12
13
P24262
P26951
S05633
S05632
P26942
27
28
357149
VOLUTE REPLACEMENT KIT
27 IMPELLER CHART
14
15
STD
PART NO.
CANADIAN
CSA/CUL
HP
SIZE
16
P28323
SEAL PA-7 W/CERAMIC SEAT
SEAL A7 s/s PS201 (CSA/CUL)
BOLT 3/8-16 X 7/8 s/s HEX hd., 4 req.
SEAL PLATE WFE - NOT AVAILABLE
SEAL PLATE WFE
16a
17
½
¾
1
WF, WFE-2, -23
WF, WFE-3, -24
WF, WFE-4, -26
WF, WFE-6, -28
WF, WFE-8, -30
WFE-12
073126
073127
073128
073129
073130
073131
357167
357168
357169
357170
357171
357172
P02811
07-3742
07-4564
18
1½
2
357173
07-0927
357159
SEAL PLATE / CUP (CSA/CUL)
FOOT WFE - 4 PUMP
19
P10311
19a
FOOT (CANADA ONLY)
3
P/N 071109
8
Rev. D
6-5-01
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Pump Curves.
Single Speed Models
Dual Speed Models
SAVE THESE INSTRUCTIONS.
Rev. D
6-5-01
9
P/N 071109
Download from Www.Somanuals.com. All Manuals Search And Download.
Pentair Pool Products WhisperFlo™
Circulating Pump Limited Warranty
Pentair Pool Products manufactures its WhisperFlo circulating
Pentair Pool Products is not, however responsible under
this warranty for any cost of shipping or transportation of
the filter or part thereof to or from the service department.
Also, Pentair Pool Products is not liable for any loss of time,
inconvenience, incidental expenses such as telephone calls,
labor or material charges incurred in connection with the
removal or replacement of the equipment, or any other
incidentalorconsequentialdamages.PLEASENOTE:Some
states do not allow the exclusion or limitation or incidental
or consequential damages, so the above limitation or
exclusion may not apply to you.
pumps under high standards of workmanship and with high
quality materials. Accordingly, Pentair Pool Products expressly
warrants those pump models as follows:
WARRANTYCOVERAGE-Allpumpcomponentparts
actually manufactured by Pentair Pool Products, and the
pump’s respective motor is warranted to be free from defects in
material and/or workmanship for a period of three (3) years from
date of purchase. The obligation of Pentair Pool Products
under this warranty will be limited to either repair or
replacement of the product, at Pentair Pool Products option.
PROCEDUREFOROBTAININGPERFORMANCE:Inorder
to obtain the benefits of this warranty the consumer who
made the original retail purchase will contact Pentair Pool
Products Customer Service Department, 10951 W. Los
Angeles Ave., Moorpark, CA 93021 as soon as possible
after discovery of the defect, but in no event later than the
expiration date of the warranty period provided in this
warranty. Upon receipt of this communication, Pentair Pool
Products will promptly notify the customer of the address to
which the defective item may be shipped. The customer
shall then ship the item, freight prepaid, to the address
indicated together with a letter stating the model number,
serial number, and the date of purchase of the item which is
claimed to be defective, and the name and address of the
consumer and a brief description of the problems
encountered.
EXCLUSIONSFROMTHISWARRANTY-Thiswarrantydoes
not cover:
1. Any item manufactured by other companies and installed
by Pentair Pool Products. Such items may carry warranties
offered by the original manufacturer.
2. Problems resulting from oversizing of pump and/or
reduction of valve piping size, or from failure to turn pump
off before changing the position of the filter valve or any
operating valves for the pool and its accessories.
3. Problems resulting from failure to comply with instructions
contained in the Owner's Manual.
4. Problems resulting from abuse, misuse, negligence or
accident by any party other than Pentair Pool Products,
such as but not limited to, damage to parts caused by
installers, damage to pump parts caused by ‘dry’ operation
(loss of prime or obstruction in plumbing lines).
WARRANTYPROTECTSORIGINALPURCHASER:This
warranty extends to the consumer who made the original
retail purchase only and is not enforceable by any other
party.
5. Problems resulting in whole or in part from alteration or
modification of the filter by any party.
6. Failures due to chemical corrosion caused by failure to
maintain the water chemistry in conformity with the
standard of the swimming pool and spa industry.
WARRANTIESORREPRESENTATIONSBYOTHERS:No
dealer or other person has any authority to make any
warranties or representations concerning Pentair Pool
Products or its products. Accordingly, Pentair Pool
Products is not responsible for any such warranties or
representations.
WARRANTYOBLIGATIONSOFPENTAIRPOOL
PRODUCTS-Shouldadefectinworkmanshipand/ormaterial
in any item covered by this warranty become evident during
the term of the warranty, then upon the consumer following the
procedures set forth below, Pentair Pool Products will, at its
option, repair or replace such item or part at its own cost and
expense.
OTHERRIGHTS:Thiswarrantygivesyouspecificlegal
rights and you may also have other rights which vary from
state to state.
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400
P/N 071109
1 0
Rev. D
6-5-01
Download from Www.Somanuals.com. All Manuals Search And Download.
|