CFW Series Filter Owner's Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Table of Contents
SECTION I.
POOL WATER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION II. NEW POOL INSTALLATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Suggested Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
To Operate Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Filter Starting Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Cleaning Required At: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SECTION III. REMOVING CARTRIDGES FOR CLEANING OR REPLACING . . . . . . . . . . . . . . . 3
How to Use the Filter Lid Opener Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cleaning Cartridges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION IV. REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
WARNING
Before installing this product, read and follow all warning notices and instructions accompanying this filter.
Failure to follow safety warnings and instructions can result in severe injury, death, and property damage.
Call (800) 831-7133 for additional free copies of these instructions.
Important Notice
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
WARNING
Failure to operate your filter system or inadequate filtration can cause poor water clarity obstructing visibility in your
pool and can allow diving in shallow pool areas, or diving into or on top of obscured objects which can cause
serious bodily injury or drowning.
Pentair Pool Products
1620HawkinsAve.,Sanford,NC27330•(919)774-4151
10951WestLosAngelesAve.,Moorpark,CA93021•(805)523-2400
Rev. C 4-23-01
1
P/N 071057
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION III. REMOVINGCARTRIDGESFORCLEANINGORREPLACING
WARNING
To prevent possible serious bodily injury, equipment damage and/or major property damage, always turn the pump off before
changing any valve positions or servicing the filter.
1. Turn pump off.
2. Drain filter--open drain valve and tank air relief valve and close all other valves.
3. To remove the clamping ring, partially unscrew the adjustment knob, releasing the head of the T-bolt from the
slotted bracket.
4. Remove tank lid with screwdriver or with the lid removal tool included with the filter (see below). Avoid cutting
rubber O-ring or bending lid or tank O-ring channel.
5. Unscrew wing nut; remove washer and holding wheel assembly.
6. Lift out cartridges and clean as described below.
7. Replace clean cartridges in manifold.
8. Replace holding wheel assembly over retaining rod; place washer over rod and then screw wing nut on rod.
CAUTION
Do not over tighten wing nut. Secure finger tight only.
9. Remove the rubber O-ring and clean both O-ring and channel. Lubricate O-ring with a non-water soluble grease,
such as silicone grease and replace O-ring in channel.
10. Clean the inside surface of the tank lid which O-ring seals against. Place lid on tank. Push down on lid to seat in
place.
11. Replace the clamping ring. Engage the head of the T-bolt into the slotted bracket and tighten the adjustment knob.
(Hand tighten only.)
12. To restore to filter operation again, refer “To Operate Filter” instructions.
13. When winterizing, insure that all water is removed from the lower internal portion of the filter.
HowtoUsetheFilterLidOpenerTool.
1. Turn pump off.
2. Open the High Flow™ manual air relief valve and wait for tank water to
drain into pool; see Figure A.
3. Remove the clamp ring.
4. Insert the filter lid opener as shown in Figure B (1). The tool fits under the
O-ring.
5. Lift the tank lid with the filter lid opener in several places around the tank; see
Figure B (2). The Pentair Pool Products Filter Lid Opener Tool may be used
on any stainless steel filter tank manufactured by Pentair Pool Products.
CleaningCartridges.
NOTE
Handle carefully to avoid puncturing pleated material.
1. The use of a garden hose with a pressure nozzle on the end will normally
be all that is required to clean dirt from cartridges.
2. If high calcium deposits are detected, they may be removed by soaking
cartridges in a solution of 1 part muriatic acid to 20 parts water. Use a
plastic pail or similar plastic container.
3. Suntan oils that have coated cartridges, thus restricting normal flow may be
removed by soaking cartridges in a mild solution of Filter Free* and water.
60 minutes of soaking time will usually break oil coating from cartridge.
Rinse with clean water.
4. Algae may be removed from cartridges by using a strong solution of Filter Free* and water. Soak cartridges as
long as necessary. Rinse with clean water. *Filter Free is a product of Hydrotech Chemical Corp.
Rev. C 4-23-01
3
P/N 071057
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION IV. REPLACEMENT PARTS, Models CFW-120, CFW-180, CFW-315, CFW-405, & CFW-560.
Item Part No. Description
1
073029
155050
071982
075207
071389
010126
073119
070548
070952
071407
197107
076033
AccessorybagCFW-120/180/315/405includes:
Gauge 1/4 in. 60 lbs.
Tee 1/4 brass
Valve air release 1/4 in.
Nipplebrass
Lid opener tool (not shown)
Lid with bushing 2000.50 includes:
Bushing 3/4 hex x 7/8
Gasket,lid
Nut 5/8-18 3/4 hex x 17-1/6
Clamp ring 2000 knob style includes:
Knob,plastic
Holding wheel assy. w/vent tube & screen cap
CFW-120
CFW-180
CFW-315
CFW-405
2
3
4
073097
073098
070233
074931
175698
075279
CFW-560
Vent tube 46 in. (not shown)
Cartridge
5
R173310 CFW-120 - 11-1/8 in.
R173312 CFW-180 - 19-1/2 in.
R173315 CFW-315 - 25-5/8 in.
R173314 CFW-405 - 16 in.
175690
073995
073996
074025
073227
071442
CFW-560 - 19 in.
Kit conversion (converts CFW-100 to CFW120
Kit conversion (converts CFW-150 to CFW180
Manifold CFW/CFM 2 in.
Kit conv. manifold w/2 in. X 1½ in., reducer bushing (not shown)
O-ring, channel 2000.47 w/red line
Tank with 2 in. nipple
CFW-120
CFW-180
CFW-315
CFW-405/560
Cap drain plug- 3/4 in. PVC
Tee 2 in. PVC SxSxFlP
Nut 1/4-20 SS hex
Washer lock 1/4 in. SS
Flat washer 1/4 x 5/8
Center rod
)
)
6
7
8
073398
073400
070235
170006
070560
9
10 071988
11 071406
12 072172
13 072183
14
Head Loss Chart - Model CFW-120, CFW-180, CFW-315,
CFW-405, & CFW-560
070664
070665
CFW-120
CFW-180
070232
CFW-315
074933
CFW-405
175691
CFW-560
15 072173
16 071404
17 075014
18 074628
Washer 5/16 i.d. X 3/4 o.d.
Nut wing 8200.30 1/4-20
Spreader CFW-405/560
Elbow 2 in. 90° PVC SXFIP
Includes: center tod, manifold & holding wheel assy.
- cartridges not included.
SAVE THESE INSTRUCTIONS.
P/N 071057
4
Rev. C 4-23-01
Download from Www.Somanuals.com. All Manuals Search And Download.
|