Installation Data
Installation Manual
PDA - Pool Digital
Assistant
Pool/Spa Combination Systems and
Pool Only/Spa Only Systems
(Models PS4, PS6, PS8, P4, and P8)
Firmware Revision 2.6
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/spa service
technician. The procedures in this manual must be followed exactly. Failure to follow warning notices
and instructions may result in property damage, serious injury, or death.
ATTENTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an electrical source on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Modifications made to this equipment, which are not authorized by the manufacturer, may void the user’s authority
to operate this equipment.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 3
Table of Contents
Section 5. Troubleshooting..................................... 25
Section 1. Important Safety Instructions.............. 4
5.1 PDA Quick Troubleshooting Guide........ 25
Section 2. System Overview ................................... 6
Section 6. Power Center Wiring Diagram ............ 27
2.1 Package Contents.................................... 6
2.2 System Component Specifications
Section 7. Power Center PCB DIP Switch
Settings ................................................... 28
and Dimensions....................................... 7
2.3 Basic Plumbing....................................... 8
7.1 DIP Switch Functions ............................. 28
Section 3. Installation ............................................. 10
7.2 DIP Switch Settings for Pool and
3.1 Power Center Mounting.......................... 10
3.2 High Voltage Wiring ............................... 10
3.3 Low Voltage Wiring................................ 14
3.4 Heater Connection .................................. 15
3.5 Temperature Sensors............................... 17
3.6 Jandy Valve Actuators............................. 17
3.7 PDA Transceiver J-box Installation ........ 17
Spa Combination..................................... 29
7.3 DIP Switch Settings for Pool or
Spa Only.................................................. 30
Section 8. General, Water Feature and
Light Aux Labels ................................... 31
Section 4. System Startup....................................... 19
4.1 Handheld Remote Programming............. 19
4.2 Restarting the System
(Clear Memory) Menu............................ 22
4.3 PDA System Defaults and
General Modes........................................ 22
4.4 PDA Handheld Remote Menu
Flow Chart .............................................. 24
EQUIPMENT INFORMATION RECORD
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL
FILTER MODEL
HORSEPOWER
SERIAL NUMBER
SERIAL NUMBER
PDA MODEL
NOTES:
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 4
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
LIRE LA NOTICE TECHNIQUE.
All electrical work must be performed by a licensed electrician and conform to all national, state, and
local codes. When installing and using this electrical equipment, basic safety precautions should always be
followed, including the following:
DANGER
To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub. Never operate a spa or hot
tub if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate
marked on the equipment assembly.
WARNING
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature
of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of
hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of the
body. The effects of hyperthermia include: 1) unawareness of impending danger; 2) failure to perceive heat; 3)
failure to recognize the need to exit spa; 4) physical inability to exit spa; 5) fetal damage in pregnant women; 6)
unconsciousness resulting in a danger of drowning.
WARNING
To Reduce the Risk of Injury -
a) The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and
104°F (40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young
children and when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of
pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
c) Before entering a spa or hot tub, the user should measure the water temperature with an accurate
thermometer since the tolerance of water temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with
the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa or hot tub since some medication
may induce drowsines while other medication may affect heart rate, blood pressure, and circulation.
WARNING
Risk of electric shock - Install the power center at least five (5) feet (152.4cm) from the inside wall of the pool
and/or hot tub using non-metallic plumbing. Canadian installations must be at least three (3) meters from the
water.
Children should not use spas or hot tubs without adult supervision.
Do not use spas or hot tubs unless all suction guards are installed to prevent body and hair entrapment.
People using medications and/or having an adverse medical history should consult a physician before using a spa
or hot tub.
AVERTISSEMENT
Danger d'electrocution - Les installations Canadiennes doivent se trouver à au moins trois (3) mètres de l’eau.
Ne pas laisser les enfants utiliser une cuve de relaxation sans surveillance.
Pour éviter que les cheveux ou une partie du corps puissent être aspirés, ne pas utiliser une cuve de relaxation si
les grilles de prise d'aspiration ne sont pas toutes en place.
Les personnes qui prennent des médicaments ou ont des problèmes de santé devraient consulter un médecin
avant d’utiliser une cuve de relaxation.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 5
WARNING
People with infectious diseases should not use a spa or hot tub.
To avoid injury, exercise care when entering or exiting the spa or hot tub.
Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible
drowning.
Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub.
Water temperature in excess of 100°F/38°C may be injurious to your health.
Before entering a spa or hot tub measure the water temperature with an accurate thermometer.
Do not use a spa or hot tub immediately following strenuous exercise.
Prolonged immersion in a spa or hot tub may be injurious to your health.
Do not permit any electric appliance (such as a light, telephone, radio, or television) within 5 feet (1.5 m) of a spa
or hot tub.
The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
Water temperature in excess of 100°F/38°C may be hazardous to your health.
AVERTISSEMENT
Les personnes atteintes de maladies infectieuses ne devraient pas utiliser une cuve de relaxation.
Pour éviter des blessures, user de prudence en entrant dans une cuve de relaxation et en sortant.
Pour éviter l’évanouissement et la noyade éventuelle, ne prendre ni drougue ni alcool avant d’utiliser une cuve de
relaxation ni quand on s’y trouve.
Les femmes enceintes, que leur grossesse soit confirmée ou non, devraient consulter un médecin avant d’utiliser
une cuve de relaxation.
Il peut être dangereux pour la santé de se plonger dans de l’eau à plus de 38°C/100°F.
Avant d’utiliser une cuve de relaxation mesurer la témperature de l’eau à l’aide d’un thermomètre précis.
Ne pas utiliser une cuve de relaxation immédiatement après un exercice fatigant.
L’utilisation prolongée d’une cuve de relaxation peut être dangereuse pur la santé.
Ne pas placer d'appareil électrique (luminaire, téléphone, radio, téléviseur, etc) à moins de 1.5m de cette cuve de
relaxation.
La consommation d’alcool ou de drogue augmente considérablement les risques d’hyperthermie mortelle dans
une cuve de relaxation.
Il peut etrê dangereux pour la santé de se plonger dans de l’eau à plus de 38°C/100°F.
WARNING
To avoid injury ensure that you use this control system to control only packaged pool/spa heaters which have built-
in operating and high limit controls to limit water temperature for pool/spa applications. This device should not be
relied upon as a safety limit control.
CAUTION
A terminal bar marked "GROUND" is provided within the power center. To reduce the risk of electrical shock,
connect this terminal bar to the grounding terminal of your electric service or supply panel with a continuous
copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying this
equipment, but no smaller than no. 12 AWG (3.3mm). In addition, a second wire connector should be bonded with
a no. 8 AWG (4.115mm) copper wire to any metal ladders, water pipes, or other metal within five (5) feet (1.52m)
of the tub.
CAUTION
A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The
conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures
containing other conductors unless the additional conductors are also protected by a ground-fault circuit-
interrupter. Refer to local codes for complete details.
Attention installer: Install to provide drainage of compartment for electrical components.
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 6
Section 2. System Overview
2.1
Package Contents
All Jandy AquaLink RS Systems come complete with the appropriate number of 3HP relays needed.
Pool Digital Assistant (PDA) System Sub-Assembly
PDA Handheld Remote
Outdoor Transceiver J-box
Power Center PCB
Two (2) Temp Sensors,
Additional Relays (Model Dependent)
Two (2) JVAs
(With Pool/Spa Combination Only)
Power Centers (Sold Separately)
Sub-Panel Power Center
(with mounting brackets and circuit
breaker mounting plate)
Standard Power Center
(with mounting brackets)
PureLink Sub-Panel Power Center
(with mounting brackets and circuit
breaker mounting plate)
PureLink Standard Power Center
(with mounting brackets)
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 7
2.2
System Component Specifications and Dimensions
Table 1
Specifications (USA and Canada)
Power Supply
120 VAC; 60 Hz; 3 A
Contact Rating (Relays)
High voltage - 25 A; 3HP @ 240 VAC
1½ HP @120 VAC
1500 Watts Incandescent
Low Voltage - Class Two, 1 A @ 24 VAC
Service Switch
All Circuits (located at Power Center in Service Mode)
Dimensions
7/8"
3½"
4"
1 1/16"
7"
6¾"
6"
1"
Front View
Side View
Front View
Side View (at Angle)
J-Box Transceiver
PDA Handheld Remote
5"
14½"
5"
14½"
20"
13¾"
Note Breakers for Sub-Panel Power Center
only.
Standard Power Center
Sub-Panel Power Center
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 8
2.3
Basic Plumbing
2.3.1 Plumbing for Pool and Spa Combination
The following plumbing diagrams illustrate
simplified versions of standard plumbing setups
for a pool and spa that share the same filter pump,
filter, and heater. The intake and return Jandy Valve
Actuators (JVAs) turn simultaneously so when the
Spa mode is selected on the AquaLink RS PDA,
water circulation switches between pool and spa
(consult the Jandy Valve Actuator Installation and
Operation Manual to ensure that the JVAs are
synchronized and rotate properly). Please consult
the Jandy Valve Plumbing Manual for further
examples of pool/spa plumbing.
Please note that if you have a pool only or a spa
only, the diagram does not apply.
NOTE When the filter system is shared (a Pool/Spa
Combo), the spa water must be able to overflow
into the pool.
From Solar
To Solar
Heat Pump
Check
Valve
Filter
Heater
Pump
Filter
Spa
Make-up
Check
Pool Drain
Valve
Pool Return
Spa Return
Spa Drain
Skimmers
Skimmers
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 9
2.3.2 Booster Pump Pool Cleaner Plumbing
Filter
Pump
Heater
Filter
Spa Make-up
Booster
Pump
Check
Valve
Pool Intake
Spa Intake
Pool Return
Spa Return
2.3.3 Non-Booster Pump Pool Cleaner Plumbing
Filter
Pump
Heater
Filter
Spa Make-up
Cleaner
Line
Check
Valve
Energy
Filter
Pool Return
Spa Return
Pool Intake
Spa Intake
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 10
Section 3. Installation
3.1
1.
Power Center Mounting
The Power Center should be located at or
near the equipment pad. Locate the Power
Center at least five (5) feet or more away
from pool/spa and five (5) feet off the
ground. All national, state, and local codes
are applicable.
Transformer
NOTE For Canadian installations, the Power Center
must be at least three (3) meters (9.8 feet)
away from the pool/spa and 1.5 meters (5 feet)
above the ground.
Filter Pump Relay
Aux. 3 Relay
Wire nut to
120 VAC power
2.
Use the mounting brackets and instructions
provided with the Standard Power Center
and/or Sub-Panel Power Center.
Earth Ground
Neutral
3.
Sub-Panel Power Centers have special
code requirements. Be sure to follow all
applicable local and state codes to insure
safe installation.
To 120 VAC
Breaker
Breaker Panel
NOTE The Power Center is not to be considered
as suitable for use as Service Equipment.
Therefore, it is required to have the appropriate
means of disconnection, circuit isolation, and/or
branch circuit protection installed upstream of
the Power Center.
Figure 1. Standard Power Center
Transformer
3.2
High Voltage Wiring
3.2.1 System Power
WARNING
Potentially high voltages in the AquaLink RS
Power Center can create dangerous electrical
hazards, possibly causing death, serious injury
or property damage. Turn off power at the main
circuit feeding the AquaLink RS Power Center to
disconnect the Power Center from the system.
White
Black
Depending on the amount of equipment being
controlled, run ½" or larger conduit from the
power supply panel to the bottom of the Power
Center. If you are using the Sub-Panel Power
Center, wire power to the appropriate breakers.
Pull in appropriate wire for equipment. Each piece
of equipment requires its own high voltage relay.
Connect 120 volts to the Power Center terminals.
Connect equipment ground(s). See Figures 1 and 2.
Black
White
Ground
Earth Ground
From Main
Power
Figure 2. Sub-Panel Power Center
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 11
3.2.2 3HP (Standard) Relays
3.2.3 Bonding the Power Center
For each piece of 240 volt equipment to be
controlled, connect line power to the two (2) line
terminals and connect equipment power to the two
(2) load terminals on the same relay.
Install a bonding lug to the Power Center
enclosure. Connect the bond lug, using a #8 solid
copper core wire, to an approved earth ground (an
approved ground stake, grid, or conducting metal
water pipe buried to a sufficient depth). See
Figure 3.
For each piece of 120 volt equipment, connect
power to a line terminal and connect equipment to
a load terminal on the same relay.
NOTE The following are the contact ratings for 3HP
(Standard) Relay. DO NOT exceed any ratings.
3 HP @ 240 VAC; 1½ HP @ 120 VAC; 25
Amps; 1500 Watts.
Earth
Ground
Bonding Lug
Filter Pump
(240 VAC)
Breaker
Panel
Blower
(120 VAC)
Figure 3. Standard Power Center - Bonding
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 12
3.2.4 Underwater Lighting GFCI Wiring
3.2.5 Jandy Pool and Spa Lights Wiring
The Jandy Pool and Spa Lights can be wired into
the Jandy AquaLink RS control system to ensure
simplified operation of the lights, as well as a
means to synchronize the color change function.
Connect the lights to one of the auxiliary relays in
the Power Center.
CAUTION
AGround Fault Circuit Interrupter (GFCI) must be
provided in high voltage pool/spa lights. Do not
use a GFCI circuit breaker.The conductors on
the load side of the GFCI circuit shall not occupy
conduit, boxes, or enclosures containing other
conductors unless the other conductors are also
on the load side of a GFCI. Refer to local codes
for complete details.
NOTE It is recommended to connect one light per
relay so each light can be controlled separately.
However, up to four lights can be connected on
a single relay. If there are more than four lights
installed on one AquaLink RS system, ensure
there is more than one auxiliary relay available
in the Power Center.
1.
For a Standard Power Center, install an
appropriately rated GFCI receptacle next to
the breaker panel. For a Sub-Panel Power
Center install an appropriately rated GFCI
receptacle in the Power Center (use the
knockout provided on the right side of the
Sub-Panel Power Center). See Figure 4.
Refer to Figures 5 and 6 to connect the Jandy Pool
and Spa Lights to the Power Center.
NOTE The Jandy Pool and Spa Lights are available
in 120-volt and 12-volt versions. If installing a
12-volt light, a 120-volt/12-volt step-down (AC)
transformer, listed/certified for the application
must be used. For more information about 12-
volt installations, refer to the Jandy Digital,Color
Changing,Underwater Pool and Spa Lights
Installation and Operation Manual.
2.
3.
Connect neutral and hot wire (from circuit
breaker) to the LINE side of the GFCI.
Connect neutral (white wire) and the hot
(black wire) from the light to the LOAD
side of the GFCI.
4.
Connect ground from the light to the
grounding bar inside the Power Center.
OPTIONAL
GFCI
Outlet
Standard Power Center
OPTIONAL
GFCI Outlet
(Optional)
Sub-Panel Power Center
Figure 4. GFCI Installation for Underwater
Lighting
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 13
120 VAC
Power Supply
120V
Jandy
Light
Junction
Box
Black
White
GFCI
Neutral
Ground
Ground
Green
Figure 5. 120-Volt Jandy Pool and Spa Light Wiring Diagram
120 VAC
Power Supply
12V
Jandy
Light
Junction
Box
Black
Black
White
120V/12V
Transformer
GFCI
Neutral
White
Green
Ground
Ground
Green
Figure 6. 12-Volt Jandy Pool and Spa Light Wiring Diagram
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 14
3.3
Low Voltage Wiring
3.3.1 Bezel Connection
Low Voltage
Raceway
Plug the 24 VAC power plug from the transformer
into its 3-pin terminal on the back of the Power
Center PCB (see Figure 7). Mount the Bezel to the
Power Center using the screws provided. Ensure
that battery wires are kept from being pinched or
damaged.
CAUTION
DO NOT INSTALL BATTERY until ready to
power up system.
Conduit Knockout for Low Voltage
PDA J-box Wire
24 VAC Power Plug
Connection
Heyco Fittings for
Low Voltage JVA
and Sensor Wires
Figure 7. Power Center PCB (back view)
High Voltage
Knockouts for
Conduit
(DO NOT run any Low
Voltage wires through
these knockouts)
3.3.2 PDA J-Box Cable Connection to Power
Center PCB
Make provision for the cable to be run between the
PDA J-box and the Power Center. Never run high
voltage and low voltage in the same conduit. Pull
cable through the knockout with the Heyco fitting
and into the low voltage compartment. Strip back
jacket 6". Strip each wire a ¼" and connect to the
red, 4-pin connector on the Power Center PCB. A
multiplex kit may be required if there are more than
two cables running to a red, 4-pin connector (see
Figure 8).
Figure 8. PDA J-Box Cable Connection to Power
Center PCB
NOTE For detailed tranceiver installation, see
Section 3.7.1.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 15
3.4
Heater Connection
3.4.2 Guidelines for Sophisticated Diagnostic
Communication to LX Heaters
The heater connection section applies to all
heaters or heat pumps with thermostatic circuitry
of 24 VAC or less (see pages 15 thru 17 for brand
specific installation).
1.
2.
Remove the LX GUI from the heater.
Confirm the LX and AquaLink RS software
revisions are compatible (see table).
NOTE If you are connecting a heater with thermostatic
circuitry of 120 VAC or greater, do not connect
to the green, 10-pin Terminal Bar. Instead,
connect the heater to a high voltage relay in
the Power Center and plug the spare relay into
the Electric Heater relay socket located on the
upper right hand corner of the Power Center
PCB.
3.
Run a 4-conductor cable from the LX GUI
red, 4-pin connector to the RS power Center
red, 4-pin connector (see Figure 10).
LX Software Revision
AquaLink RS Software
Revision
C10, C11 or later
PDA 1.0 or later
3.4.1 Jandy Brand Heater Connections
NOTE If connecting more than two (2) items to the RS
Power Center red, 4-pin connector, a Multiplex
PCB is required.
1.
Connect two #14 gauge wires, designed for
use in hot environments, to the #1 and #2
terminals on the green, 10-pin Terminal Bar.
PDA
J-box
2.
Connect the other ends of the #14 gauge
wires from Step 1 to the Fireman's Switch
terminal bar in place of the factory installed
wire loop.
4 3 2 1
3.
4.
5.
Do not disconnect high limit or pressure
switches.
OPTIONAL
Turn the heater thermostat(s) to maximum
setting.
4-Conductor
Wire
Turn the heater switch to the ON position.
For dual thermostat heaters turn switch to
Spa position.
RS Power
Center
Green 10-pin
Terminal Bar
#14
Gauge
Wire
RED
BLK
YEL
GRN
Heater Toggle
Switch To On
LX GUI
Power Center PCB/Bezel
Figure 10. LX Heater Connection to Power Center
Factory
Installed
Wire Loop
Heater
Thermostat To
Max.
3.4.3 Other Brands Heater Connections
To set up heater connections on heaters
manufactured by Hayward, Pentair, and Raypak,
please refer to the Installation Manual provided
with these heaters.
Heater
Wiring
Terminal 1
Terminal 2
Heater Fireman's Switch
Connection
Figure 9. Lite2 Heater Connection
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 16
3.4.4 Guidelines for a Gas Heater and a Jandy
AE Series Heat Pump/Chiller Installation
NOTE The following steps provide the procedure for
4.
5.
Connect the Heat Pump to a standard
relay, then connect the relay to the solar
pump output on the PCB. Set the time to
11:59 PM; at 12:00 AM, the AquaLink
RS will auto-relabel Solar as Heat Pump.
Otherwise, the AquaLink RS will auto-
relabel Solar as Heat Pump within 24 hours.
installing a Jandy AE Series Heat Pump.
1.
2.
Install a fixed resistor, with a value of 2.2K
Ohms, in the solar sensor terminals #3 and
#4 of the green, 10-pin terminal bar of the
AquaLink RS Power Center (see
Figure 16).
The Solar Button will activate the heat
pump/chiller and the Pool and/or Spa
Heater Buttons will activate the gas heater.
In this manner the pool or spa can be heated
or chilled by the heat pump, the gas heater
or both.
To run the wires from the Heat Pump,
remove the 5 screws that attach the service/
wiring cover panel to the heat pump (see
Figure 16).
NOTE One end of the wiring reserved to run into
the conduit connection labeled “Low Voltage
Connection”, located on the lower right hand
side of the heat pump (see Figure 16).
NOTE To program the Heat Pump control panel, refer
to the Jandy AE Series Heat Pump Manual.
3.
Run the wires from the Heat Pump control
panel through the wiring conduit located on
the outer right hand side of the Heat Pump.
2.2K Ohms Resistor
in Solar Sensor
Terminals for Heat
Pump/Chiller
To Pressure
Switch
Gas Heater Connections
Terminals 1 and 2
Fireman's
Switch
4
3
2
1
6
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
From Fusible
Link
PDA
Transceiver
J-box
Gas Heater
Battery
(9Volt)
Heat Pump/Chiller #2
Standard
High
Voltage
Relay
To Heat Pump #2
Heat Pump/Chiller #1
Port for Low
Voltage Wires
Low Voltage
To Heat Pump #1
Wiring to Low
Voltage Port
Service/Wiring
Cover Panel
on Heat Pump
Port for Low
Voltage Wires
Service/Wiring
Cover Panel
Figure 16. Heater and Heat Pump/Chiller Wiring
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 17
3.5
1.
Temperature Sensors
NOTE Do not coil the JVA wires inside Power Center.
To shorten the wire, remove the JVA cover
and disconnect the wire. Shorten, strip, and
reconnect.
Drill 3/8" hole in pipe between filter
pump and filter and install the Water
Temperature Sensor per instructions
(make certain the o-ring is in place).
3.
For alternate plumbing configurations the
JVA cam settings can be adjusted as needed.
See the Jandy Valve Actuator Installation
and Operation Manual, Cam Setting Chart
for proper settings.
2.
Install Air Temperature Sensor outside the
Power Center can, not in direct sunlight and
away from motors and other heat sources.
3.
4.
Install Solar Temperature Sensor
(optional) adjacent to solar panels.
3.7
PDA Transceiver J-box Installation
Run the wire to the Power Center, through
the low voltage raceway. Cut off excess
wire. Strip the wire jacket back 6", then
strip each wire ¼". Connect sensor wires to
the green, 10-pin terminal bar (see
Figure 17).
Installation Considerations. The transceivers will
transmit through walls and around corners. Steel
framing, aluminum siding, wrought iron, cyclone
fences, leaded glass, and other 900 MHz frequency
items may inhibit/prevent communication between
the AquaLink RS PDA Handheld Remote and the
Power Center. The transceivers do not require
line of sight to communicate. To optimize
communication, install transceivers in a location
that minimizes interference.
Solar
Temperature
Water
Sensor
Temperature
Sensor
3.7.1 Outdoor Transceiver J-box Installation
Freeze/Air
Temperature
Sensor
1.
Turn off all power to the Power Center.
2.
Mount the Outdoor Transceiver J-box at
least 6' above the ground and at least 8'
from an air blower (see Figure 18).
10 9 8 7 6 5 4 3 2 1
Green 10-Pin Terminal Bar
NOTE To improve performance of the transceiver,
Figure 17. Temperature Sensor Wiring for a Pool/
Spa Combination
mount the J-box more than 6' above the ground.
3.
4.
5.
Open the door to the Power Center and
remove the dead panel.
3.6
Jandy Valve Actuators
Feed the four conductor wire into the Power
Center through the low voltage raceway.
NOTE Mount the JVAs according to the Jandy Valve
Actuator Installation and Operation Manual.
Cut off the excess wire. Strip the jacket
back 6" and strip the individual wires
approximately ¼". Connect the four
conductor wire to the red terminal bar on
the Power Center PCB.
JVA cable is type SJW-A marked water resistant
class 3 cable and does not require conduit.
Knockouts and Heyco fittings are provided in the
Low Voltage Raceway.
1.
2.
Route the JVA wire to the Power Center.
6.
Install the dead panel to the Power Center
and restore all power.
Run the wire through the low voltage
raceway and plug the JVA connectors into
their proper sockets (see Section 6. Power
Center Wiring Diagram). Verify that the
JVA on the suction plumbing is connected
to the Intake JVA Socket, and the discharge
plumbing is connected to the Return JVA
Socket.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 18
3.
4.
Install two (2) AA batteries. Ensure that the
polarity is correct.
Air
Blower
PDA
Transceiver
J-box
Minimum 8'
Re-install the cover for the battery chamber
and secure with the two (2) screws removed
in Step 2.
3.7.3 Changing the Frequency Channel
6'
If your AquaLink RS PDA system is turning items
on or off at undesignated times, another AquaLink
RS PDA system may be in close proximity using
the same or similar frequency channel. To prevent
unwanted operation the channel for your AquaLink
RS PDA system can be changed. The Power Center
Transceiver and the PDA Transceiver J-box must
be set to the same RF channel.
Low Voltage Raceway
Ground
Level
Power
Center
1.
At the Transceiver J-box, remove the cover
to expose the PCB (see Figure 20).
Red 4-Pin
Terminal Bar
Figure 18. Outdoor Transceiver J-box Installation
Green
LED
3.7.2 PDA Handheld Remote Installation
1.
Remove the Handheld Remote from the
packaging.
Red
LED
Learn
Switch
2.
On the back of the Handheld Remote,
loosen and remove the two (2) screws that
secure the cover for the battery chamber
(see Figure 19).
Transceiver
PCB
PDA Handheld
Remote - Back View
Reset Switch
Two (2)
AA Batteries
Figure 20. PDA Transceiver J-Box - Internal View
2.
On the PDA Handheld Remote, press
and hold both the UP and DOWN arrows
simultaneously for three (3) seconds. After
3 seconds, the CHANNEL SETUP screen
appears (see Figure 21). Select a channel.
Screws
UM-3/R6/AA
BATTERY
1.5V x 2
UM-3/R6/AA
Battery Chamber
Cover for Battery
Chamber
Figure 19. Battery Installation on Handheld Remote
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 19
6.
7.
On the PDA Handheld Remote display
screen, a prompt will appear with
instructions to slide the J-box Learn Switch
out of LEARN (OFF) and to press the J-box
Reset Switch.
SET RF CHANNEL
RF CHANNEL:
1
Use ARROW KEYS
to set the
UP
Button
RF CHANNEL.
Press SELECT to
continue.
At the PCB in the Transceiver J-box, slide
the Learn Switch out of LEARN and press
the Reset Switch. The Red and Green LEDs
on the J-box will blink simultaneously (see
Figure 22).
DOWN
Button
SELECT Button
Section 4. System Startup
4.1
Handheld Remote Programming
Figure 21. PDA Handheld Remote Channel Setup
and Buttons
4.1.1. Basic Programming Menu
3.
Use the UP and DOWN buttons to highlight
the desired RF channel. Then press
SELECT.
To set a particular piece of equipment to turn on
and off at predetermined times, highlight MENU
and press SELECT (see Figure 23). Highlight
PROGRAM and press SELECT. Use the UP or
DOWN buttons to highlight the equipment (for
example, Filter Pump) then press SELECT. Follow
the on-screen prompts. Use the UP or DOWN
buttons to pick each number, starting with ON
hours, press SELECT to enter and move on to the
next item to change, including picking what day(s)
the program will run. If you make a mistake, use
the BACK button to return to a number. If the
program is already entered, highlight CHANGE
PROGRAM and step through to the entry that
should be corrected.
4.
When the RF channel is selected, the
following message appears on the PDA
display screen:
Set slide switch on J-Box PCB to the
LEARN MODE.
5.
At the PCB in the Transceiver J-box, slide
the Learn Switch to LEARN (ON). See
Figure 22.
Green
LED
Red
LED
Learn
Switch
UP
Button
Shown
in Learn
Mode
- Switch
Position
On.
Power ON/OFF
BACK
Button
Button
HOT KEY 2
SELECT
Reset Switch
Transceiver
Button
DOWN
Button
PCB
HOT KEY 1
Figure 22. Tranceiver J-box PCB Learn Switch
Figure 23. PDA Handheld Remote Buttons
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 20
4.1.2 Set the Time Menu
Pool/Spa Only - Highlight MENU and press
SELECT. Highlight SET TEMP and press SELECT
(see Figure 26). The message TEMP1 must be
higher than TEMP2 is displayed. Highlight TEMP1
and press SELECT. Use the UP or DOWN button
to increase or decrease the temperature and press
SELECT. Highlight TEMP2 and press SELECT.
Use the UP or DOWN button to increase or
To set the time, highlight the MENU and press
SELECT. Highlight SET TIME and press SELECT
(see Figure 24). Use the UP or DOWN button to set
the values. Press SELECT to continue.
MAIN MENU
HELP
decrease the temperature and press SELECT. Use
the BACK button to return to the main screen.
PROGRAM
SET TEMP
SET TIME
PDA OPTIONS
SYSTEM SETUP
MAIN MENU
SET TEMP
TEMP1
80°F
60°F
HELP
TEMP2
PROGRAM
SET TEMP
SET TIME
PDA OPTIONS
SYSTEM SETUP
Highlight an
item and press
SELECT
Figure 24. Set Time Menu
SET TEMP
TEMP1
TEMP2
SET TEMP
TEMP1
TEMP2
4.1.3 Set the Temperature Menu
80°F
60°F
85°F
60°F
Pool/Spa Combination - Highlight MENU and
press SELECT. Highlight SET TEMP and press
SELECT (see Figure 25). Use the UP or DOWN
button to highlight either POOL or SPA and press
SELECT. Use the UP or DOWN button to increase
or decrease the temperature and press SELECT.
Use the BACK button to return to the main screen.
Highlight an
item and press
SELECT
Highlight an
item and press
SELECT
Figure 26. Set Temperature Menu - Pool/Spa Only
MAIN MENU
SET TEMP
POOL HEAT
80°F
HELP
SPA HEAT
104°F
PROGRAM
SET TEMP
SET TIME
PDA OPTIONS
SYSTEM SETUP
Highlight an
item and press
SELECT
4.1.4 Label Auxiliary Functions Menu
Highlight MENU and press SELECT. Highlight
SYSTEM SETUP and press SELECT (see
Figure 27). Highlight LABEL AUX and press
SELECT. Highlight the AUX you want to label
and press SELECT. Highlight GENERAL, LIGHT,
WATERFALL or CUSTOM LABEL and press
SELECT. Choose a name within these categories
by using the UP or DOWN button. Press SELECT
when you find the correct label. Choose CUSTOM
to type in your own labels.
SET TEMP
SET TEMP
POOL HEAT
SPA HEAT
80°F
104°F
POOL HEAT
SPA HEAT
85°F
104°F
Highlight an
item and press
SELECT
Highlight an
item and press
SELECT
NOTE The Auxiliary labels AIR BLOWER and FILL
LINE have an automatic 30 minute runtime.
If DIP switch 1,2 or 3 are on, auxiliaries 1, 2
and 3 are labeled CLEANER, LOW SPEED
and SPILLOVER respectively and cannot be
Figure 25. Set Temperature Menu - Pool/Spa
Combination
relabeled.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 21
SYSTEM SETUP
LABEL AUX
MAIN MENU
SYSTEM SETUP
LABEL AUX
MAIN MENU
FREEZE PROTECT
AIR TEMP
HELP
FREEZE PROTECT
AIR TEMP
HELP
PROGRAM
PROGRAM
SET TEMP
DEGREES C/F
TEMP CALIBRATE
SOLAR PRIORITY
PUMP LOCKOUT
ASSIGN JVAs
MORE
SET TEMP
DEGREES C/F
TEMP CALIBRATE
SOLAR PRIORITY
PUMP LOCKOUT
ASSIGN JVAs
MORE
SET TIME
SET TIME
PDA OPTIONS
SYSTEM SETUP
PDA OPTIONS
SYSTEM SETUP
FREEZE PROTECT
FREEZE PROTECT
DEVICES
LABEL AUX
LABEL AUX1
AUX1
AUX2
AUX3
AUX4
AUX5
AUX6
AUX7
CURRENT LABEL
AUX1
TEMP
38°F
FILTER PUMP
SPA
SOLAR HEAT
AUX1
AUX2
AUX3
X
X
Use ARROW KEYS
to set value.
Press SELECT
to continue
GENERAL LABELS
LIGHT LABELS
WTRFALL LABELS
CUSTOM LABEL
MORE
LABEL AUX1
GENERAL LABELS
AUX1
AERATOR
AIR BLOWER
BACKWASH
BOOSTER PUMP
CHEM FEED
CLEANER
MORE
Figure 28. Freeze Protection Menu
4.1.6 Assign JVAs Menu
Highlight MENU and press SELECT. Highlight SYS-
TEM SETUP and press SELECT (see Figure 29).
Highlight ASSIGN JVA and press SELECT. Highlight
the JVA you wish to assign and press SELECT.
NOTE If a solar sensor is installed, the Solar JVA will
automatically be assigned and will be marked
as USED.
Figure 27. Label Aux Menu
4.1.5 Set Freeze Protection Menu
Highlight MENU and press SELECT. Highlight
SYSTEM SETUP and press SELECT (see Figure
28). Highlight FREEZE PROTECT and press
SELECT. Use the UP or DOWN button to change
the temperature. Once the temperature is set press
the SELECT button to move to the next screen
to assign freeze protection to a selected piece of
equipment. Highlight a device and press SELECT.
"X" means the device has been assigned.
SYSTEM SETUP
MAIN MENU
LABEL AUX
FREEZE PROTECT
AIR TEMP
HELP
PROGRAM
SET TEMP
SET TIME
DEGREES C/F
TEMP CALIBRATE
SOLAR PRIORITY
PUMP LOCKOUT
ASSIGN JVAs
MORE
PDA OPTIONS
SYSTEM SETUP
ASSIGN JVAs
ASSIGN
CLEANER JVA
INTAKE
USED
NO ASSIGNMENT
AUX1
AUX2
RETURN
CLEANER
SOLAR
USED
FREE
USED
NOTE The filter pump is always assigned to freeze
AUX3
AUX4
protection.
AUX5
AUX6
Figure 29. Assign JVA Menu
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 22
4.2
Restarting the System (Clear Memory)
Menu
4.3
PDA System Defaults and General Modes
Default Temperature (Pool/Spa Combination)
Default Pool Temp = 80° F
Default Spa Temp = 102° F
To remove all labeling, programming, assignments
and temperature settings, highlight MENU and
press SELECT. Highlight SYSTEM SETUP
and press SELECT (see Figure 30). Highlight
CLEAR MEMORY and press SELECT. Highlight
CONTINUE and press SELECT. Use the UP or
DOWN button to highlight YES or NO and press
SELECT. There will be about a 15 second delay
before you see the FINISHED screen. Highlight
CONTINUE and press SELECT to return to the
SYSTEM SETUP.
Default Temperature (Pool/Spa Only)
Default TEMP1 = 80° F
Default TEMP2 = 60° F
Default Spa Side Switch Settings
Button 1 = Spa (Filter Pump for pool/spa only models)
Button 2 = Spa Heater (Temp1 pool/spa only models)
Button 3 = AUX1
Button 4 = AUX2
Default Freeze Protection Settings
Filter Pump: Freeze Protection ON.
All Other Equipment: Freeze Protection OFF
Default Activation Temperature: 38° F
SYSTEM SETUP
MAIN MENU
SOLAR PRIORITY
PUMP LOCKOUT
ASSIGN JVAs
COLOR LIGHTS
SPA SWITCH
SERVICE INFO
CLEAR MEMORY
HEAT PUMP
HELP
PROGRAM
SET TEMP
SET TIME
PDA OPTIONS
SYSTEM SETUP
NOTE If you select SPA to be freeze protected, water
circulation will switch between pool and spa
every 30 minutes during freezing conditions
once freeze mode is active.
MORE
4.3.1 Power Center Service Switch
AUTO Mode (automatic)
CLEAR MEMORY
CLEAR MEMORY
WARNING
FINAL WARNING
Are you SURE
that you want to
ERASE ALL
SETTINGS
??
Clearing memory
erases ALL
stored settings.
1. The PDA Handheld Remote has complete
control of all functions.
YES
NO
CONTINUE
2. All programmed settings will operate.
3. All safety delays and equipment protection
interlocks are operational.
SERVICE Mode
CLEAR MEMORY
CLEAR MEMORY
FINISHED
ERASING
ALL
1. The power center has complete control of
all functions.
SETTINGS
Press SELECT
to continue.
please wait
CONTINUE
2. Service mode must be turned on/off at the
power center.
3. No programmed settings will work.
CAUTION
In service mode, equipment protection safety
interlocks are overridden.
Figure 30. Clear Memory Menu
TIMEOUT Mode
1. The power center has complete control for
three (3) hours.
2. After three (3) hours the system will return
to AUTO mode.
3. Programmed on/off times will be
overridden during the three (3) hours.
4. After the three (3) hour "time out", the
system will resume any programmed items
that were overridden.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 23
Battery Backup
A nine-volt battery is located at the power center.
The battery keeps the clock running during a
power outage so the time and date will be correct
when power is restored. Programming will not be
lost even if the battery is dead. Do not install the
battery in the power center until the system is ready
to operate. Battery will drain if power is left off.
Review DIAGNOSTICS in the SYSTEM SETUP
section of the menu. The DIAGNOSTICS will
indicate when the battery needs replacement.
ATTENTION
Special Note to Startup Person: The
AquaLink RS PDA allows two (2) options for
operating the pool equipment on the first day of
operation:
Option #1 - Once all programming of equipment
is completed, the AquaLink RS PDA will
automatically review all programs and turn on
any equipment which is programmed to be on.
Option #2 - To operate the filter pump or
cleaner continually for the first day, leave the
power center service button in AUTO mode.
Using the PDA Handheld Remote, turn on the
filter pump or the equipment you want to run.
NOTE If the equipment has already been turned on
by a program time, turn the equipment off
and then back on.
The equipment that is activated will run
continuously, ignoring the first programmed
off time, and will turn off at the programmed
off time for the next day (only if a program has
been entered).
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 24
4.4
PDA Handheld Remote Menu Flow Chart
MODEL
SENSORS
REMOTES
ERRORS
SELECT
EQUIPMENT
SERVICE
ON
EQUIPMENT
ON/OFF
DIAGNOSTICS
OFF
ALL OFF
POOL HEAT
SPA HEAT
CHILL †
HELP
ADD PROGRAM
DELETE
SELECT
EQUIPMENT
PROGRAM
2 MINUTES
CHANGE
SET TEMP
SET TIME
5 MINUTES
SET MONTH, DAY,
YEAR & TIME
10 MINUTES
SET
OUTPUT %
SET AQUAPURE†
PDA OPTIONS
SET AUTO-OFF
LIGHT ON
BACKLIGHT
LIGHT OFF
1
2
ASSIGN HOTKEYS
MENU
SELECT
DEVICE
GENERAL LABELS
LIGHT LABELS
LABEL AUX
AQUAPURE†
SET TIME
MODE ††
SELECT
LABEL
POOL
WTRFALL LABELS
SPILLOVER
CUSTOM LABELS
(TYPE PERSONALIZED
DESCRIPTION)
SELECT
DEVICE
FREEZE PROTECTION
AIR TEMP
SET TEMP
ENABLED
DISABLED
FAHRENHEIT
CELCIUS
DEGREES F/C
TEMP CALIBRATE
SET TEMP
ENABLED
DISABLED
SOLAR HEAT PRIORITY †
INTAKE
RETURN
SYSTEM
SETUP
ENABLED
DISABLED
PUMP LOCKOUT
ASSIGN JVAs
CLEANER
SOLAR
ASSIGN TO AUX
JANDY LIGHT
COLOR LIGHTS
SAM/SAL LIGHT
COLOR LOGIC LIGHT
1
SPA SWITCH
SERVICE INFO
CLEAR MEMORY
HEAT MODE
CHILL MODE
HEAT PUMP †
BOOST †
START
GO BACK
†
Items Seen Only With Optional Equipment
Mode Only Displayed When DIP Switch #3 is Set to ON
††
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 25
Section 5. Troubleshooting
5.1
PDA Quick Troubleshooting Guide
The AquaLink RS PDA will stop communicating
anytime interference (such as a 900 MHz device)
prevents a valid signal transmission. When
communication is lost the PDA Handheld Remote
will lock on the startup screen until a good link
is again achieved, usually within a few seconds.
If communication is not reestablished within
a few seconds or this happens often, use the
troubleshooting information in the following table
for suggestions.
Symptom
Problem
Possible Solution
Replace batteries.
Power Center override switches Dead batteries in the PDA
operate when in Service or
Time Out Mode, but the PDA
Handheld Remote is completely
dead (no backlight on or
display).
Handheld Remote.
PDA Handheld Remote
PDA is not communicating with Check the two center wires (black & yellow) of
backlight is on and the startup
screen is displayed. The
override switches at the power
center operate as they should.
the power center PCB.
the four conductor cable to the transceiver
J-box. Also check the installation of the PPD on
the power center PCB. If the PPD is not seated
correctly the system will not communicate.
PDA Handheld Remote
backlight is on and the startup
screen is displayed, but
1. Damaged or improperly
installed PPD.
1. Check alignment of the PPD.
override switches at the power
center do not operate at all.
2. Wrong PPD.
2. Make sure that the PPD is for a PDA.
3. Damaged power center
PCB.
3. If PPD is installed correctly, replace the
power center PCB.
Some buttons do not operate
from the PDA Handheld
Wrong PPD chip installed at
the power center PCB.
Ensure that the PPD revision number is the
correct revision required for the application.
Remote, nor from the power
center override switches.
System locked up.
Microprocessor locked.
Turn off power to the system. Disconnect
battery at the Power Center and turn on power.
Reconnect the battery and reset time and date.
Programs do not run at the
correct time.
AquaLink RS does not display At the PDA Handheld Remote, set correct time
correct time and date.
and date. In Diagnostics, check battery level.
If LOW BATTERY is displayed, replace battery
at the Power Center to ensure correct time and
date are maintained.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 26
Symptom
Problem
Possible Solution
One button on the Four
Function Remote does not
operate.
Check programming first. If
the Four Function Remote
is programmed correctly, the
button may be shorted.
Replace the Four Function Remote. Use MENU,
REVIEW, SPA SWITCH to check programming.
NOTE If dip switch 1
(CLEANER) is on, button # 3
on the Four Function Remote
will not operate when in spa
mode unless this button is
programmed to a circuit other
than Aux 1.
Pool cleaner booster pump
System is not recognizing DIP Turn off all equipment buttons, then turn off
turns on without the filter pump switch #1 is on.
being on, and can run with the
power to the system, finally turn off, then on, DIP
switch #1. Turn on power and test system.
spa on.
NOTE Before turning on any
DIP switches, first turn off all
equipment. Do not program
any auxiliaries until all DIP
switches are set.
System comes on at times that Phantom programs.
are not programmed.
At the PDA press MENU, then select
PROGRAM. Make note of all programs (the
Four Function Remote setting, labels, and
temperature settings) then turn off all DIP
switches and go to the PDA. CLEAR MEMORY,
reprogram and try system again.
Heater will not fire. Heater LED Water temperature sensor not Check water temperature sensor.
will not light in "Service Mode". installed or defective.
LCD screen display stays on
startup screen.
No communication between
PDA Handheld Remote and
Power Center J-box.
Change the Frequency Channel. See Section
3.7.3.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 27
Section 6. Power Center Wiring Diagram
Elect.
Heater
Return
JVA
Solar
JVA
Intake
JVA
Cleaner
JVA
Solar
Pump
4 3 2 1 6 5 4 3 2 1
JVA Sockets
(24 VAC output)
Relay Sockets
(24 VDC output)
To Controller
To Remote
To Sensors, etc.
(green terminal bar)
Dip Switch Settings
Factory Setting When Turned
(red terminal bar) (brown terminal bar)
#
1
2
3
4
5
6
OFF
ON
MP
Aux 1
Cleaner
U
P
R
TE
L
I
1 SPD Pump
Aux 3
Cool Down
Normal
Spare Aux
2 SPD Pump
Spa Spillover
Disabled
See Manual
Spare Aux
F
(Pool Mode) (Spa Mode)
See Manual See Manual
Heater 3 min. Heater 5 min.
Relay Sockets (24 VDC output)
Relay Sockets (24 VDC output)
Aux. 4 Aux. 5 Aux. 6
7
8
Aux. 1 Aux. 2 Aux. 3
F. Pump
Off
Off
Battery
(9Volt)
Filter Pump Relay
Aux. 4 Relay
Aux. 3 Relay
Aux. 7 Relay
Aux. 1 Relay
Aux. 2 Relay
Aux. 5 Relay
Aux. 6 Relay
System Power
Grounding Bar
Wire Nut to
120VAC Power
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 28
Section 7. Power Center PCB DIP
Switch Settings
IMPORTANT Do not program equipment ON/OFF
DIP #4 ON- Heater Cool Down Disabled
times until all DIP switches are set.
Turn this switch ON to disable the heater cool
down safety feature on the AquaLink RS.
7.1
DIP Switch Functions
DIP #1 ON- AUX 1 Controls Pool Cleaner
CAUTION
If you installed a booster pump for a pool cleaner,
the relay coil for the booster pump must be plugged
into the AUX 1 relay socket. If a non-booster
pump cleaner is installed, plug the JVA into the
cleaner JVA socket. Turn ON DIP Switch #1.
Turn this DIP Switch ON only if you are using
an electric heater or a heat pump that does
not retain residual heat. If you are turning this
switch ON for service purposes, be sure to turn
it back off.
•
Main filter pump turns on whenever cleaner
turns on.
DIP #5 ON- Factory Use Only
•
Cleaner will not turn on until filter pump
has been on for three (3) minutes (to ensure
priming of system).
This switch is used for calibration by Jandy
certified technicians only. Please leave this switch
in the OFF position.
•
•
•
Cleaner turns off when water circulation is
to spa.
DIP #6 ON - Pool/Spa Combination Systems Only
Change Spare AUX to activate when Filter Pump is
on and system is in spa mode. Spare AUX socket is
on the back side of the Power Center PCB.
Cleaner turns off when spa spillover feature
is activated.
Cleaner turns off for three (3) minutes when
solar is activated (to ensure air is purged
from the system).
DIP #7 ON- Not Used
Dip #8 ON- Heat Pump Instead of Gas Heater
•
AquaLink RS PDA Handheld Remote
display reads "CLEANER" rather than
"AUX 1".
Turn this switch ON if you have installed a heat
pump instead of a gas heater. After thermostat
setting has been reached, heater will remain OFF
for 5 minutes.
DIP #2 ON- AUX 2 Controls Low Speed of Filter
Pump
Turn this switch ON if you want to control both
speeds of a two-speed filter pump. With this switch
on, the filter pump button on the AquaLink RS
PDA will control high speed and the HOT KEY 2
(default) button will control low speed.
IMPORTANT You must also install a Jandy Two-
Speed Relay.
DIP #3 ON- AUX 3 Controls Spa Spillover
(Operates with Pool/Spa Combination)
Turn this switch ON, and when the AUX 3 button
on the AquaLink RS PDA (or Spa Side Switch) is
pressed, the Return Valve Actuator will rotate to
spa circulation. Because the Intake Valve Actuator
does not rotate, the spa will fill with water and
overflow into the pool.
NOTE Leave AUX 3 relay socket empty.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 29
OFF ON
1
2
3
4
5
6
7
8
Factory setting is with all DIP
switches off.
7.2
DIP Switch Settings for Pool and Spa Combination
DIP Switch #
OFF
AUX1= any equipment
ON
AUX1= Pool Cleaner
1
2
AUX2= any equipment
AUX2= Low Speed for a two-speed filter
pump.
Filter pump circuit becomes High Speed.
3
AUX3= any equipment
AUX3= Spa Spillover effect- Combination
controls only.
4
5
Heater cool down operates.
Normal operation
Heater cool down disabled.
Factory adjustment- when this switch is on,
temperature delays are eliminated.
Do not leave this switch in the ON
position.
6
7
8
Spare Aux activates with Filter Pump when
Spa OFF.
Spare Aux activates with Filter pump with
Spa on.
Spare
No change on Combination or Only
Controls.
After thermostat setting has been reached,
heater will remain OFF for 3 minutes.
After thermostat setting has been reached,
heater will remain OFF for 5 minutes.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 30
DIP Switch Settings for Pool or Spa Only
7.3
DIP Switch #
OFF
AUX1= any equipment
ON
AUX1= Pool Cleaner
1
2
AUX2= any equipment
AUX2= Low Speed for a two-speed filter
pump.
Filter pump circuit becomes High Speed.
3
4
5
AUX3= any equipment
Heater cool down operates.
Normal operation
No change
Heater cool down disabled.
Factory adjustment- when this switch is on,
temperature delays are eliminated.
Do not leave this switch in the ON
position.
6
7
8
Spare
Spare
No change
No change
After thermostat setting has been reached,
heater will remain OFF for 3 minutes.
After thermostat setting has been reached,
heater will remain OFF for 5 minutes.
Download from Www.Somanuals.com. All Manuals Search And Download.
Page 31
Section 8. General, Water Feature and Light Aux Labels
General Labels
Light Labels
Waterfall Labels
Aerator
#1
Waterfall
Air Blower
Backwash
Booster Pump
Chem Feed
Cleaner
Color Wheel
Drain Line
Fan
#2
#3
Back
Basement
Beach
Bedroom
Bug
Cabana
Color Wheel
Deck
Waterfall 1
Waterfall 2
Waterfall 3
Sheer Dscnt
Rockfall
Laminar Jet
Fiber Optic
Fill Line
Filter Pump
Floor System
Fogger
Dock
Drive
East
Fountain
Heat Pump
Heater
Entry
Equipment
Fan
Hi-E2
Fence
Flood
Fountn
Front
Garage
Garden
Gazebo
Hall
House
Kitchen
Laminar Plsr
Left
High Speed
Home A/C
Home Heat
Jet Pump
Lite
Lamp
Low Speed
Mist
Music
Not Used (see note)
Ozonator
Pond
North
Ray-Vac
Slide
Path
Patio
Solar Pump
Spa
Perimeter
Pond
Spillway
Pool
Sprinkler 1
Sprinkler 2
Sprinkler 3
Stereo
Porch
Right
Room
Sauna
Security
Shower
Shrub
South
Spa
Statue
Steps
Table
Stream
Swim Jet
Timed Aux
Valve(s)
Wtr Feature
Whirlpool
Tier
Tree
Walk
Water Ftr
Wtrfll
West
Yard
NOTE Please be aware that if the label NOT USED from the GENERAL LABEL menu is used on an AUX relay, the relay will not
engage.
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
Thank you for purchasing Jandy® pool and spa products. Jandy Pool Products, Inc. warrants all parts to be free
from manufacturing defects in materials and workmanship for a period of one year from the date of retail
purchase, with the following exceptions:
AquaLink® RS units installed with Jandy® Surge Protection Kits will be covered for two years.
•
NeverLube® valves are warranted for the life of pool and/or spa on which they were originally installed.
•
AquaPureTM Electronic Chlorine Generator Electrolytic Cells carry a 5 year limited warranty on a prorated basis.
•
This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have
been moved from their original installation sites. The liability of Jandy Pool Products, Inc. shall not exceed the
repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the
defective part, transportation to or from the factory, and any other materials required to make the repair. This
warranty does not cover failures or malfunctions resulting from the following:
1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation,
Operation and Maintenance Manuals provided with the product(s).
2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total
Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000 not including salt ppm].
4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing
sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.
9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-Rings,
DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.
LIMITATION OF LIABILITY:
This is the only warranty given by Jandy Pool Products, Inc. No one is authorized to make any other warranties
on behalf of Jandy Pool Products, Inc. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS
FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. JANDY POOL PRODUCTS, INC. EXPRESSLY
DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT OR
PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY. This warranty gives
you specific legal rights. You may also have other rights which vary by state or province.
WARRANTY CLAIMS:
For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase,
model number, serial number and date of installation. The installer will contact the factory for instructions
regarding the claim and to determine the location of the nearest designated service center. If the dealer is not
support department at (707) 776-8200 extension 260. All returned parts must have a Returned Material
Authorization number to be evaluated under the terms of this warranty.
ETL LISTED
CONFORMS TO
UL STD 1563
PDA HANDHELD REMOTE
FCC ID: S8F826X
PDA TRANSCEIVER
FCC ID: S8F8252
CERTIFIED TO
CAN/CSA C22.2 NO. 218.1
Jandy Pool Products, Inc.