Pella Window 801U0102 User Manual

©2008 Pella Corporation  
Part Number: 801U0102  
INSTALLATION INSTRUCTION – INSTRUCCIONES DE INSTALACION  
FOR CLAD FIXED FRAME AND CIRCLEHEAD WINDOWS  
5PQ  
'MBTIJOHꢀ  
5BQF  
8JOEPXꢀ5PQ  
0VUFSꢀ  
7FSUJDBM  
'MBTIJOHꢀ  
5BQF  
0VUFSꢀ  
7FSUJDBM  
'MBTIJOHꢀ  
5BQF  
0VUFSꢀ$PSOFS  
'MBTIJOHꢀ5BQF  
4JEF  
'MBTIJOH  
5BQF  
'JOꢀ$PSOFS  
/BJMJOHꢀ'JO  
4JEF  
8JOEPXꢀ#PUUPN  
'MBTIJOH  
5BQF  
4JMMꢀ'MBTIJOHꢀ5BQFꢀꢁꢂ  
4JMMꢀ'MBTIJOHꢀ5BQFꢀꢁꢃ  
8BUFSꢀ3FTJTUJWFꢀ#BSSJFS  
4IFBUIJOH  
'SBNJOH  
Always read the Pella® Limited Warranty before purchasing or installing Pella  
products. By installing this product, you are acknowledging that this Limited  
Warranty is part of the terms of the sale. Failure to comply with all Pella installation and maintenance  
instructions may void your Pella product warranty. See Limited Warranty for complete details at  
Installation Instructions for Typical Wood Frame Construction.  
These instructions were developed and tested for use with typical wood frame wall construction  
in a wall system designed to manage water. These instructions are not to be used with any  
other construction method. Installation instructions for use with other construction methods,  
multiple units or bow and bay windows, may be obtained from Pella Corporation, a local Pella  
retailer, or by visiting http://www.pella.com. Building designs, construction methods, building  
materials, and site conditions unique to your project may require an installation method  
different from these instructions and additional care. Determining the appropriate installation  
method is the responsibility of you, your architect, or construction professional.  
YOU WILL NEED TO SUPPLY:  
TOOLS REQUIRED:  
s 4APE MEASURE  
s ,EVEL  
s #EDAR OR )MPERVIOUS SHIMSꢀSPACERS ꢁꢂꢃ TO ꢃꢄ  
s ꢃꢅ GALVANIZED ROOlNG NAILS ꢁꢂꢀꢆ LBꢇ  
s #LOSED CELL FOAM BACKER RODꢀSEALANT BACKER ꢁꢂꢃ TO ꢈꢄ FTꢇ  
s 0ELLA® SmartFlashfoil backed butyl window and  
door flashing tape or equivalent  
s 3QUARE  
s (AMMER  
s (IGH QUALITY EXTERIOR GRADE POLYURETHANE OR  
SILICONE SEALANT ꢁꢂ TUBE PER WINDOW  
4&"-"/5  
s 3TAPLER  
s 'REAT 3TUFF Window and Door Insulating Foam Sealant  
by the Dow Chemical Company or equivalent low pressure  
polyurethane window and door foam - DO NOT use high  
PRESSURE OR LATEX FOAMS  
s 3CISSORS OR UTILITY KNIFE  
s 3EALANT GUN  
s )NTERIOR TRIM ANDꢀOR JAMB EXTENSIONS ꢁꢂꢉ TO ꢆꢄ FTꢇ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETTING AND FASTENING THE WINDOW  
2
A. Install and level sill spacers. 0LACE ꢂꢅ WIDE BY ꢈꢀꢋꢅ THICK SPACERS  
ON THE BOTTOM OF THE WINDOW OPENING ꢂꢀꢃꢅ FROM EACH SIDEꢇ 3PACERS  
are also required at points where windows are joined in multiple  
window applications. Add shims as necessary to ensure the  
spacers are level. Once level, attach spacers and shims to prevent  
movement.  
Óꢀ  
Note: Improper placement of shims or spacers may result in  
bowing the bottom of the window.  
B. Remove plastic wrap and cardboard packaging from window.  
Note: If grilles are removed from the window at this time, label them and store them in a  
protected area.  
C. Fold out installation fin to 90°. /N UNITS WITH PREꢌAPPLIED lN CORNERSꢍ BE CAREFUL NOT TO  
REMOVE OR TEAR THE lN CORNERSꢇ  
Note: If the fin is not at 90°, the window will not line up correctly on the interior.  
ꢀ#  
ꢌꢍ¡  
Óꢁ  
$*3$-&)&"%ꢀ8*5)  
'-&9*#-&ꢀ'*/  
47/ /2 -/2% 0%/0,% 7),, "% 2%15)2%$ &/2 4(% &/,,/7).' 34%03ꢇ  
D. Insert the window from the exterior of the building. Place the bottom of the window on  
the spacers at the bottom of the opening, then tilt the top into position. Center the window  
BETWEEN THE SIDES OF THE OPENING TO ALLOW CLEARANCE FOR SHIMMINGꢍ AND INSERT ONE ROOlNG NAIL  
IN THE lRST HOLE FROM THE CORNER ON EACH END OF THE TOP NAILING lNꢇ 4HESE ARE USED TO HOLD THE  
window in place while shimming it plumb and square.  
Óꢀ  
Óꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E. Plumb and square window. 0LACE SHIMS ꢂꢅ  
from the bottom and top of the window between  
the window and the sides of the opening. Adjust  
the shims as required to plumb and square the  
window in the opening. If the frame height  
EXCEEDS ꢉꢈꢅꢍ PLACE SHIMS AT THE MIDPOINT  
of the window sides.  
Óꢅ  
£
ꢂ ꢃꢄꢁ-  
ä
““  
Ó
ä
Ó
Î
Î
{
ä
x
ä
È
ä
Ç
ä
Note: DO NOT shim above the  
window or in the space between  
the spacers at the bottom of the  
window. DO NOT over shim.  
Óꢁ  
F. Check the interior reveal. Make sure the  
measurement from the interior face of the  
window to the interior face of the wall is  
equal at several points around the window.  
Note: If the dimensions are not equal,  
check to make sure the fins are folded out  
to 90˚ at all points.  
Óꢆ  
'JYFEꢀ  
&YUSVEFEꢀ'JO  
'ꢇ Fasten the window to opening. /N WINDOWS WITH A lXED  
Óꢄ  
EXTRUDED lNꢍ DRILL ꢂꢀꢋ DIAMETER HOLES IN THE lN EVERY ꢂꢃꢅꢇ  
(ꢇ Drive a 2" galvanized roofing nail into each of the pre-punched and pre-drilled holes.  
For flexible fin: $RIVE NAILS UNTIL THE HEAD CONTACTS THE lNꢍ HOWEVER DO NOT SINK THE HEADꢇ  
This allows for movement of building materials.  
Note: Make sure all fin corners are lying as flat as possible.  
INTEGRATING THE WINDOW TO  
THE WATER RESISTIVE BARRIER  
A. Units that do not have pre-applied fin corners: #UT FOUR PIECES OF mASHING TAPE ꢂꢌꢂꢀꢃꢅ LONGꢇ  
!PPLY ONE PIECE OF mASHING TAPE TO EACH END OF THE SILL lN SO THAT IT EXTENDS ꢂꢌꢂꢀꢃꢅ PAST THE  
END OF THE SILL lNꢇ !PPLY ONE PIECE OF  
3
flashing tape to the bottom end of  
Îꢇ  
EACH mEXIBLE lNꢍ BEGINNING ꢂꢌꢂꢀꢃꢅ  
FROM THE END OF THE lNꢍ AND LAPPING  
OVER THE mASHING TAPE THAT EXTENDS  
FROM THE END OF THE SILL lNꢇ  
TU  
Îꢇ  
OE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Apply side flashing tape. #UT TWO PIECES OF mASHING TAPE ꢆꢅ  
longer than the frame height of the window. Apply one piece  
ꢂꢀꢃꢅ UP ONTO THE FRAME CLADDING OVER THE NAILING lN AND ONTO  
THE WATER RESISTIVE BARRIER TO EACH SIDEꢇ 4HE TAPE SHOULD EXTEND  
ꢃꢅ ABOVE THE TOP OF THE WINDOW AND ꢃꢅ BELOW THE BOTTOM OF  
THE WINDOWꢇ 0RESS THE TAPE DOWN lRMLY WHILE FOLDING DOWN THE  
EXCESS TAPE AT THE TOP AND BOTTOM OF THE WINDOWꢇ  
Note: DO NOT tape or seal the bottom nailing fin.  
Î
C. Apply top flashing tape. Cut a piece of  
flashing tape long enough to go across the  
TOP OF THE WINDOW AND EXTEND AT LEAST ꢂꢅ PAST  
Î
the side flashing tape on both sides. Apply  
Îꢃ  
THE TAPE ꢂꢀꢃꢅ UP ONTO THE FRAME CLADDING  
OVER THE TOP NAILING lN AS SHOWNꢇ &OLD THE  
overlapping tape down, and press all tape  
DOWN lRMLYꢇ  
ꢂꢇ  
ꢂꢇ  
#ꢂꢇ Apply top flashing tape to circle top windows. Several pieces of flashing tape will be needed  
TO COVER THE TOP lNꢇ 3TART TAPING FROM THE SIDES OF THE WINDOW WORKING TOWARD THE PEAKꢇ 4O  
determine the length of cuts, hold the tape along the radius, and cut the tape just past where it  
LEAVES THE TOP lXED EXTRUDED lN OR FOR THE mEXIBLE lNꢍ JUST PAST THE mEXIBLE WEATHER STRIPꢇ 4HE  
top tape must overlap the one beneath it in order to divert water properly. The sharper the arc  
of the window, the shorter the pieces of tape will be.  
#ꢃꢇ Apply top flashing tape to an angle top window 1/2" up  
onto the frame cladding, over the top fin onto the sheathing.  
/N THE SHORT SIDE OF A TRAPEZOID WINDOWꢍ DO NOT ALLOW THE SIDE  
mASHING TAPE TO EXTEND HIGHER THAN WHAT THE TOP TAPE WILL COVERꢇ  
&OLD THE OVERLAPPING TAPE DOWNꢍ AND PRESS ALL TAPE DOWN lRMLYꢇ  
Îꢃ£  
Îꢀ  
&YUFSJPS  
D. Fold down top flap of water resistive barrier (3D).  
Îꢁ  
E. Apply flashing tape to diagonal cuts. Cut pieces of  
mASHING TAPE AT LEAST ꢂꢅ LONGER THAN THE DIAGONAL CUTS  
in the water resistive barrier. Apply the tape covering  
the entire diagonal cut in the water resistive barrier  
at both upper corners of the window. If vertical  
cuts were also made, apply flashing tape to  
them in the same manner.  
Îꢁ  
Note: The top tape must overlap the tape  
below it to divert water properly. Be sure  
to overlap the top corners (3D).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTERIOR SEAL  
4
Caution: Ensure use of low pressure polyurethane window and door insulating foams  
and strictly follow the foam manufacturer’s recommendations for application. Use of high  
pressure foams or improper application of the foam may cause the window frame to bow and  
hinder operation.  
A. Apply insulating foam sealant. From the interior, insert the  
NOZZLE OF THE APPLICATOR APPROXIMATELY ꢂꢅ DEEP INTO THE SPACE  
BETWEEN THE WINDOW AND THE ROUGH OPENING AND APPLY A ꢂꢅ  
DEEP BEAD OF FOAMꢇ 4HIS WILL ALLOW ROOM FOR EXPANSION OF THE  
FOAM AND WILL MINIMIZE SQUEEZE OUTꢇ )F USING FOAM OTHER THAN  
'REAT 3TUFFWindow and Door Insulating Foam Sealant  
by the Dow Chemical Company, allow the foam to cure  
COMPLETELY ꢁUSUALLY ꢋ TO ꢃꢆ HOURS BEFORE PROCEEDING TO THE  
NEXT STEPꢇ  
{ꢇ  
Note: DO NOT completely fill the space from the back of  
the fin to the interior face of the opening.  
SEALING THE WINDOW TO THE  
EXTERIOR WALL CLADDING  
When applying siding, brick veneer or other exterior finish material, leave adequate space  
between the window frame and the material for sealant. Refer to the illustration that  
corresponds to your finish material.  
5
Note: The sealant details shown are standard recommendations from the sealant industry.  
Contact your sealant supplier for recommendations and instructions for these and any  
other applications.  
800%ꢀ4*%*/(  
8*5)ꢀ53*.  
#3*$,ꢀ7&/&&3  
4FBMBOUꢀUZQJDBM  
#BDLFSꢀ3PEꢀBOE  
4FBMBOUꢀUZQJDBM  
ꢊꢋꢎꢇꢀ$MFBSBODF  
ꢊꢋꢎꢇꢀ$MFBSBODF  
*OTVMBUJOH  
'PBN  
*OTVMBUJOH  
'PBN  
"DDFTTPSZꢀ(SPPWF  
"DDFTTPSZꢀ(SPPWF  
1FSJNFUFSꢀ4FBMBOUꢀ  
NVTUꢀFYUFOEꢀUPꢀ  
SPPNTJEFꢀPGꢀ  
1FSJNFUFSꢀ4FBMBOUꢀ  
NVTUꢀFYUFOEꢀUPꢀ  
SPPNTJEFꢀPGꢀ  
"DDFTTPSZꢀ(SPPWFꢉ  
"DDFTTPSZꢀ(SPPWFꢉ  
ꢊꢋꢎꢇ  
ꢊꢋꢎꢇ  
ꢊꢋꢎꢇ  
.JOꢉ  
ꢊꢋꢎꢇ  
.JOꢉ  
7*/:-ꢋ45&&-  
4*%*/(  
800%  
4*%*/(  
#BDLFSꢀ3PEꢀBOE  
4FBMBOUꢀUZQJDBM  
ꢊꢋꢎꢇꢀ$MFBSBODF  
4FBMBOUꢀUZQJDBM  
ꢂꢋꢎꢇꢀ$MFBSBODF  
*OTVMBUJOH  
'PBN  
*OTVMBUJOH  
'PBN  
"DDFTTPSZꢀ(SPPWF  
1FSJNFUFSꢀ4FBMBOUꢀ  
NVTUꢀFYUFOEꢀUPꢀ  
SPPNTJEFꢀPGꢀ  
"DDFTTPSZꢀ(SPPWFꢉ  
ꢊꢋꢎꢇ  
ꢂꢋꢎꢇ  
ꢊꢋꢎꢇ  
.JOꢉ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A. Insert closed cell foam backer rod into the space around the  
WINDOW SO THERE IS APPROXIMATELY ꢈꢀꢋꢅ CLEARANCE BETWEEN THE  
BACKER ROD AND THE EXTERIOR FACE OF THE WINDOWꢇ  
Note: Backer rod adds shape and depth for the sealant line.  
xꢇ  
B. Apply a bead of high quality exterior grade sealant to  
the entire perimeter of the window.  
Note: For wood siding applications, when using  
the flexible fin, ensure the sealant bead covers the  
exterior edge of the fin weather-strip.  
C. Shape, tool and clean excess sealant. 7HEN lNISHEDꢍ  
the sealant should be the shape of an hourglass.  
Note: This method creates a more flexible sealant  
line capable of expanding and contracting.  
x
INTERIOR FINISHING  
)F PRODUCTS CANNOT BE lNISHED IMMEDIATELYꢍ COVER WITH CLEAR PLASTIC TO PROTECT FROM DIRTꢍ DAMAGE  
AND MOISTUREꢇ 2EMOVE ANY CONSTRUCTION RESIDUE BEFORE lNISHINGꢇ 3AND ALL WOOD SURFACES LIGHTLY  
WITH ꢂꢋꢄ GRIT OR lNER SANDPAPERꢇ $/ ./4 USE STEEL WOOLꢇ "% #!2%&5, ./4 4/ 3#2!4#(  
4(% ',!33ꢇ 2EMOVE SANDING DUSTꢇ  
0ELLA PRODUCTS MUST BE lNISHED PER THE BELOW INSTRUCTIONSꢎ FAILURE TO FOLLOW THESE INSTRUCTIONS  
voids the Limited Warranty.  
s /N CASEMENT AND AWNINGSꢍ IT IS OPTIONAL TO PAINTꢍ STAIN OR lNISH THE VERTICAL AND HORIZONTAL SASH  
edges.  
s /N SINGLEꢌHUNG AND DOUBLEꢌHUNGꢍ DO NOT PAINTꢍ STAIN OR lNISH THE VERTICAL SASH EDGESꢍ ANY lNISH  
ON THE VERTICAL SASH EDGES MAY CAUSE THE SASH TO STICKꢎ IT IS OPTIONAL TO PAINTꢍ STAIN OR lNISH THE  
HORIZONTAL SASH EDGESꢇ  
s /N PATIO DOORSꢍ IT IS OPTIONAL TO PAINTꢍ STAIN OR lNISH THE VERTICAL AND HORIZONTAL PANEL EDGESꢇ  
Note: To maintain proper product performance do not paint, finish or remove the weather-  
stripping, mohair dust pads, gaskets or vinyl parts. Air and water leakage will result if these  
parts are removed. After finishing, allow venting windows and doors to dry completely before  
closing them.  
0ELLA #ORPORATION IS NOT RESPONSIBLE FOR INTERIOR PAINT AND STAIN lNISH IMPERFECTIONS FOR ANY  
PRODUCT THAT IS NOT FACTORYꢌAPPLIED BY 0ELLA #ORPORATIONꢇ 5SE OF INAPPROPRIATE lNISHESꢍ SOLVENTSꢍ  
brickwash, or cleaning chemicals will cause adverse reactions with window and door materials and  
voids the Limited Warranty.  
&OR ADDITIONAL INFORMATION ON lNISHING SEE THE 0ELLA /WNERgS -AUAL OR GO TO www.pella.com.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Additional cutting patterns  
)BMGꢀ$JSDMF  
2VBSUFSꢀ$JSDMF  
'VMMꢀ$JSDMF  
0WBM  
$JSDMFꢀ)FBE  
3JHIUꢀ5SJBOHMF  
0DUBHPO  
"SDIꢀ)FBE  
%PHꢀ)PVTF  
5SBQF[PJE  
3FDUBOHMF  
EXTERIOR FINISH  
4HE EXTERIOR FRAME AND SASH ARE PROTECTED BY ALUMINUM CLADDING WITH OUR %NDURA#LAD® or  
%NDURA#LAD 0LUS BAKEDꢌON FACTORY lNISH THAT NEEDS NO PAINTINGꢇ #LEAN THIS SURFACE WITH MILD  
soap and water. Stubborn stains and deposits may be removed with mineral spirits. DO NOT  
use abrasives. DO NOT scrape or use tools that might damage the surface.  
5SE OF INAPPROPRIATE lNISHESꢍ SOLVENTSꢍ BRICKWASH OR CLEANING CHEMICALS WILL CAUSE ADVERSE  
reactions with window and door materials and voids the Limited Warranty.  
CARE AND MAINTENANCE  
Care and maintenance information is available in the Pella Owner’s Manual. You can obtain  
an owner’s manual by contacting your local Pella retailer. This information is also available  
IMPORTANT NOTICE  
"ECAUSE ALL CONSTRUCTION MUST ANTICIPATE SOME WATER INlLTRATIONꢍ IT IS IMPORTANT THAT THE WALL  
system be designed and constructed to properly manage moisture. Pella Corporation is not  
RESPONSIBLE FOR CLAIMS OR DAMAGES CAUSED BY ANTICIPATED AND UNANTICIPATED WATER INlLTRATIONꢎ  
DElCIENCIES IN BUILDING DESIGNꢍ CONSTRUCTION AND MAINTENANCEꢎ FAILURE TO INSTALL 0ELLA PRODUCTS IN  
ACCORDANCE WITH 0ELLAꢏS INSTALLATION INSTRUCTIONSꢎ OR THE USE OF 0ELLA PRODUCTS IN WALL SYSTEMS WHICH  
do not allow for proper management of moisture within the wall systems. The determination  
of the suitability of all building components, including the use of Pella products, as well as the  
design and installation of allow for proper management of moisture within the wall systems. The  
determination of the suitability of all building components, including the use of Pella products,  
as well as the design and installation of flashing and sealing systems are the responsibility of the  
Buyer or User, the architect, contractor, installer, or other construction professional and are not  
the responsibility of Pella.  
Pella products should not be used in barrier wall systems which do not allow for proper  
MANAGEMENT OF MOISTURE WITHIN THE WALL SYSTEMSꢍ SUCH AS BARRIER %XTERIOR )NSULATION AND &INISH  
3YSTEMSꢍ ꢁ%)&3 ꢁALSO KNOWN AS SYNTHETIC STUCCO OR OTHER NONꢌWATER MANAGED SYSTEMSꢇ %XCEPT  
IN THE STATES OF #ALIFORNIAꢍ .EW -EXICOꢍ !RIZONAꢍ .EVADAꢍ 5TAHꢍ AND #OLORADOꢍ Pella makes  
no warranty of any kind on and assumes no responsibility for Pella windows and doors  
installed in barrier wall systems. In the states listed above, the installation of Pella Products  
in barrier wall or similar systems must be in accordance with Pella’s installation instructions.  
0RODUCT MODIlCATIONS THAT ARE NOT APPROVED BY 0ELLA #ORPORATION WILL VOID THE ,IMITED 7ARRANTYꢇ  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips Clock Radio AJ260 93 User Manual
Philips Stereo System AZ2000 User Manual
Pico Macom Satellite TV System SIRD FTA User Manual
Pioneer DVD Recorder DVR 105 User Manual
Pioneer Speaker System S HTD330 User Manual
Polaris Offroad Vehicle 7174820 User Manual
Prima Bread Maker ABM10 User Manual
ProForm Fitness Equipment 83129948 User Manual
PYLE Audio Car Stereo System PLD179U User Manual
PYLE Audio Car Video System PLD 169U User Manual