BB14 Series
Intercept® Back Box
Installation/
Operation Manual
C454M-C (1/98)
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
LIST OF ILLUSTRATIONS
Figure
Page
1
2
3
“T-Bar” Clip Installation .......................................................................9
Backup Plate Installation...................................................................11
24 VAC Back Box Wiring Diagram
(for Dome Drives with Integral Receiver/Driver) ................................14
120 VAC Back Box Wiring Diagram
(for Dome Drives with Integral Receiver/Driver) ................................15
230 VAC Back Box Wiring Diagram
4
5
(for Dome Drives with Integral Receiver/Driver) ................................16
Wiring Diagram, Hard-Wire Control with Heater ...............................18
Wiring Diagram, Hard-Wire Control without Heater ..........................19
Suspended Ceiling Back Box Exploded Assembly Diagram.............21
Hard Ceiling Back Box Exploded Assembly Diagram .......................22
Pendant Back Box Exploded Assembly Diagram..............................23
Back Plate Exploded Assembly Diagram ..........................................24
Suspended/Hard Ceiling Dimension Drawings .................................27
Pendant-Mount Dimension Drawing .................................................27
6
7
8
9
10
11
12
13
LIST OF TABLES
Table
Page
A
B
C
D
E
F
Video Coaxial Cable Requirements .................................................13
24 VAC Wiring Distances ..................................................................13
Suspended Ceiling Back Box Exploded Assembly Parts List ...........21
Hard Ceiling Back Box Exploded Assembly Parts List......................22
Pendant Back Box Exploded Assembly Part List ..............................23
Back Plate Exploded Assembly Parts List (Figure 11)......................25
REVISION HISTORY
Manual #
C454M
Date
—
Comments
Original version.
C454M-A
6/95
Revised to incorporate B.O.M. quantity changes as per
ECO# 94-445. Added 4-position terminal block information
as per ECO# 94-042. Incorporated new “Front” labeling
to B.O.M. as per ECO# 94-192. Updated manual to new
style standards. Added manual revision history.
6/23/95
Addendum. Incorporated new fuse and fuse holder into
wiring diagrams and exploded view diagram as per
ECO# 95-063.
2/27/96
4/96
Addendum. Section 5.0 Mechanical Parts List revised.
C454M-B
C454M-C
Rev. B. Added Section 3.4.2.1 and Figure 16 per ECO#
96-061. Changed heater specifications.
1/98
Changed manual to new format and manual pagination.
Reduced number of models. Revised installation
instructions. Updated exploded assembly diagrams and
parts lists.
Pelco Manual C454M-C (1/98)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
(This page intentionally left blank.)
4
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
1.0 GENERAL
1.1 IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be
observed.
1. Installation and servicing should only be done by Qualified Service Personnel
and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or
6P enclosure, it is designed for indoor use only and it must not be installed
where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resis-
tance measurement between line and exposed parts to verify the exposed
parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four
(4) times the weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this
unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C454M-C (1/98)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
1.2 UNPACKING INSTRUCTIONS
Unpack and inspect all parts carefully.
Be sure to save the shipping carton and any inserts. They are the safest material in
which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its
carton and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replace-
ment. (International customers fax 1-559-348-1120 for authorization and instruc-
tions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY
AND RETURN section of this manual for instructions.
The following items are supplied:
Suspended Ceiling Models
1
1
Back box with face plate, trim ring, and dome
Parts bag
2
4
Eye bolts with nuts, flat washers and split lock washers
T-rail clips
1
Installation/Operation Manual (C454M-C)
Hard Ceiling Models
1
1
Back box with trim ring and dome
Installation/Operation Manual (C454M-C)
Pendant Models
1
1
1
1
1
1
Bezel with dome
Pendant cap
Back box
Back box gasket
Parts bag with two O-rings (outdoor models only)
Installation/Operation Manual (C454M-C)
1.3 RECOMMENDED TOOLS
Pelco does not supply basic tools needed for the installation process. The following
tools are recommended:
Medium Phillips screwdriver
Wire cutter
Wire stripper
BNC crimp tool
Coaxial cable stripper
Hammer and punch (suspended ceiling model only)
Large Phillips screwdriver (suspended ceiling model only)
11 mm wrench (suspended ceiling model only)
Drill (hard ceiling models only)
6
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 DESCRIPTION
The BB14 Series of back boxes is part of the IDS14 Intercept® Series of domes.
The IDS14 Series is an integral system that includes a back box (BB14), dome
drive or fixed mount (DD14), and dome receiver/driver (DRD14).
This manual cover the BB14 Series of back boxes. For installation and operation
instructions for the dome drive, refer to manual C458M-B; for the fixed mount, refer
to C291M-B; and for the dome receiver/driver, refer to C466M-E.
2.1 MODELS
Indoor, Suspended-Grid Ceiling
BB14A100
BB14A101
BB14A110
BB14A111
BB14A120
BB14A121
BB14A130
BB14A131
Indoor back box for suspended-grid ceiling; smoked dome;
hard-wire control. (CE)
Indoor back box for suspended-grid ceiling; clear dome; hard-
wire control. (CE)
Indoorbackboxforsuspended-gridceiling; smokeddome;120
VAC input. (UL)
Indoor back box for suspended-grid ceiling; clear dome; 120
VAC input. (UL)
Indoor back box for suspended-grid ceiling; smoked dome; 24
VAC input. (CE, UL)
Indoor back box for suspended-grid ceiling; clear dome; 24
VAC input. (UL)
Indoorbackboxforsuspended-gridceiling; smokeddome;230
VAC input. (CE)
Indoor back box for suspended-grid ceiling; clear dome; 230
VAC input. (CE)
Indoor, Hard Ceiling
Indoor back box for hard ceiling; smoked dome; hard-wire
BB14C100
BB14C101
BB14C110
BB14C111
BB14C120
BB14C121
BB14C130
BB14C131
control. (CE, UL)
Indoor back box for hard ceiling; clear dome; hard-wire control.
(CE, UL)
Indoorbackboxforhardceiling; smokeddome;120VACinput.
(UL)
Indoor back box for hard ceiling; clear dome; 120 VAC input.
(UL)
Indoor back box for hard ceiling; smoked dome; 24 VAC input.
(CE, UL)
Indoor back box for hard ceiling; clear dome; 24 VAC input.
(CE, UL)
Indoorbackboxforhardceiling; smokeddome;230VACinput.
(CE)
Indoor back box for hard ceiling; clear dome; 230 VAC input.
(CE)
Pelco Manual C454M-C (1/98)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Indoor, Pendant
BB14E100
Indoor, black, pendant-mount back box; smoked dome; hard-
wire control. (CE, UL)
BB14E101
BB14E110
BB14E111
BB14E120
BB14E121
BB14E130
BB14E131
Indoor, black, pendant-mount back box; clear dome; hard-wire
control. (CE, UL)
Indoor, black, pendant-mount back box; smoked dome; 120
VAC input. (UL)
Indoor, black, pendant-mount back box; clear dome; 120 VAC
input. (UL)
Indoor, black, pendant-mount back box; smoked dome; 24
VAC input. (CE, UL)
Indoor, black, pendant-mount back box; clear dome; 24 VAC
input. (CE, UL)
Indoor, black, pendant-mount back box; smoked dome; 230
VAC input. (CE)
Indoor, black, pendant-mount back box; clear dome; 230 VAC
input. (CE)
Outdoor, Pendant
Outdoor, gray, pendant-mount back box; smoked dome; hard-
BB14E200
BB14E200-2
BB14E200-3
BB14E201
BB14E201-2
BB14E201-3
BB14E210
BB14E211
BB14E220
BB14E221
BB14E230
BB14E231
wire control. Includes 120 VAC heater and blower. (CE)
Outdoor, gray, pendant-mount back box; smoked dome; hard-
wire control. Includes 24 VAC heater and blower. (CE)
Outdoor, gray, pendant-mount back box; smoked dome; hard-
wire control. Includes 230 VAC heater and blower. (CE)
Outdoor,gray,pendant-mountbackbox;cleardome;hard-wire
control. Includes 120 VAC heater and blower. (CE)
Outdoor, gray, pendant-mount back box; smoked dome; hard-
wire control. Includes 24 VAC heater and blower. (CE)
Outdoor, gray, pendant-mount back box; smoked dome; hard-
wire control. Includes 230 VAC heater and blower. (CE)
Outdoor, gray, pendant-mount back box; smoked dome; 120
VAC input. Includes 120 VAC heater and blower. (UL)
Outdoor, gray, pendant-mount back box; clear dome; 120 VAC
input. Includes 120 VAC heater and blower. (UL)
Outdoor, gray, pendant-mount back box; smoked dome; 24
VAC input. Includes 24 VAC heater and blower. (CE, UL)
Outdoor, gray, pendant-mount back box; clear dome; 24 VAC
input. Includes 24 VAC heater and blower. (CE, UL)
Outdoor, gray, pendant-mount back box; smoked dome; 230
VAC input. Includes 230 VAC heater and blower. (CE)
Outdoor, gray, pendant-mount back box; clear dome; 230 VAC
input. Includes 230 VAC heater and blower. (CE)
8
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
3.0 INSTALLATION
3.1 MOUNTING
NOTE: If you are going to install a
heater/blower kit, it should be done
before installing the back box. Refer
to Section 3.2.3, HEATER/BLOWER
KIT FIELD INSTALLATION.
The Intercept® Series of domes provide back box configurations for several applica-
tions and environments (refer to Figures 12 and 13).
Installation instructions for the applications listed below will appear in the following
order:
1. Suspended ceiling mounting
2. Hard ceiling mounting
3. Pendant mounting
3.1.1 Suspended Ceiling Mounting
To mount the back box into a suspended ceiling grid, perform the following steps:
NOTE: When installing into a 2' x 4'
(.61 m x 1.22 m) ceiling grid, cut the
ceiling tile in half and install an addi-
tional “T” rail for support.
1. Determine the location for mounting the back box and remove the appropriate
ceiling tile.
2. Angle the back box through the grid opening and set the box into the grid.
3. From an opening in a grid adjacent to the back box apply the four (4) clips
supplied to the “T” bar to secure the back box to the grid (refer to Figure 1).
4. If additional support is required (such as anchoring with a chain or steel cable
to a support beam above the dome enclosure), install one or both of the 1/4-20
eye bolts and washers that are supplied in the parts bag:
a. Remove one or two of the 1/4-20 screws in the top of the back box.
b. Screw a nut about a half inch onto an eyebolt.
c. Slide a split lock washer and flat washer onto the eyebolt.
d. Screw the eyebolt into the back box and lock the eyebolt into place by
tightening the nut with an 11 mm wrench.
e. Repeat steps b-d if you are going to install the second eyebolt.
f.
Use a chain or cable to fasten the eyebolt(s) to a support structure in the
ceiling.
Figure 1. “T-Bar” Clip Installation
Proceed to Section 3.2, WIRING INSTRUCTIONS.
Pelco Manual C454M-C (1/98)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.2 Hard Ceiling Mounting
For installing the back box in a hard ceiling, an optional backup plate is provided for
applications where additional reinforcement to the ceiling structure is needed.
To mount the back box directly into a hard ceiling, perform the following steps.
1. Determine the location of the back box. Ideally the back box cutout should be
adjacent to any ceiling structure.
2. Cut the opening in the ceiling (16-13/16" in diameter).
3. Insert the back box into the opening. Mark spots to drill holes through the side
of the back box at the locations where fasteners need to be located. Remove
the back box and drill the holes.
4. Using the appropriate fasteners (not supplied) attach the back box to any
adjacent structure through the drilled holes in the box.
Proceed to Section 3.2, WIRING INSTRUCTIONS.
3.1.2.1 Optional Backup Plate Installation
A backup plate assembly is supplied with all back boxes to be installed in hard
ceilings, and is for use in applications where additional reinforcement to the ceiling
structure is needed. To install the backup plate, do steps 1 through 2 in Section
3.1.2 and then proceed as follows. Refer to Figure 2.
1. Insert the back box into the opening in the ceiling and mark the ceiling with the
locations of four of the screw holes in the flange. The holes must be 90° apart.
2. Remove the back box and drill 13/64" screw holes in the ceiling at the marked
points.
3. Insert the two (2) pieces of the backup plate through the large hole and posi-
tion them around the opening. Connect the two halves using the studs pro-
vided.
4. Align the nuts in the plate with the four (4) screw holes in the ceiling.
5. Insert the back box into the ceiling, and align the screw holes in the ceiling
with the holes in the flange of the back box.
6. Attach the back box to the backup plate with four (4) 6-32 screws provided.
7. Use appropriate fasteners (not supplied) to attach the back box to any adja-
cent structure through the holes drilled in the side of the back box.
Proceed to Section 3.2, WIRING INSTRUCTIONS.
10
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
3.1.3 Pendant Mounting
The pendant back box is designed to be suspended from a suitable length of 1-1/2”
pipe threaded at both ends. This pipe can be interfaced to the IWM Series or IDM4018
wall mounts or to the MRWA wall adapter mount or MRCA ceiling adapter mount.
To install the pendant type back box, perform the following steps:
NOTE: The length of pipe used may
effect noticeable motion on the video
display. If this occurs additional sup-
port of the pipe by bracing, guy wir-
ing, etc. will be required.
1. Select and install the mount of choice according to the instructions provided
with the mount. This may be a good time to route any needed wiring through
the mount. Refer to Section 3.2, WIRING INSTRUCTIONS.
2. Select the appropriate length of pipe (2-1/2" minimum length) and thread into
the mount. Tighten to approximately 30 ft/lb and tighten any locking means
that may be provided on the mount.
NOTE: For outdoor models apply
pipe thread sealant to the pipe threads
prior to assembly.
3. Slide the back box “cap” up the pipe.
On outdoor units first slide one (1) of the two (2) O-rings up the pipe, followed
by the “cap” and the second O-ring.
On indoor models while holding the “cap” in place, bring the back box into
place and engage the threaded flange on the back box with the pipe. (Be sure
to back out the locking screw in the flange prior to this.)
4. Spin the back box onto the pipe. The latches inside the back box may be used
as handles to provide a light torque to the box (approximately 20 ft/lb). Tighten
the lock screw.
5. Lower the “cap” onto the top of the back box. On outdoor models also lower
the external O-ring until it contacts the “cap”.
Proceed to Section 3.2, WIRING INSTRUCTIONS.
Figure 2. Backup Plate Installation
Pelco Manual C454M-C (1/98)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 WIRING INSTRUCTIONS
How your back box will be wired depends on the type of unit you have:
Units with an on-board receiver/driver
Units without an on-board receiver/driver (hard-wire applications)
Hardwire refers to installations using a remote receiver/driver or a true hardwire
controller.
Proceed to either Section 3.2.1, On-Board Receiver/Driver, or Section 3.2.2,
Hardwire or Remote Receiver/Driver.
3.2.1 On-Board Receiver/Driver
On models for suspended ceilings or hard ceilings, a plate is provided on the top of
the back box with 1/2" and 3/4" conduit knockouts.
1. Bring the wiring to the back box.
Video - Refer to Table A for the type of video coaxial cable to use.
Power - If the input power to the dome is 24 VAC, refer to Table B to determine
the size of wire to use. For outdoor units, make sure the wiring can supply
power for the heaters and fan as well as the receiver/driver. Refer to Section
5.0, SPECIFICATIONS, for power requirements.
Control - If you are using a Coaxitron® controller, the control signals to operate
the dome drive will be transmitted over the video coax.
If you are not using a Coaxitron® controller, bring wires to the back box for two
(2) RS-485 control lines (RX+ and RX-).
Refer to Figure 3, 4, or 5 for the following steps.
2. Install the coaxial cable to the BNC connector.
3. Install power to the 10-position terminal block. Make sure the power switch on
the side of the back box is off.
4. If you are not using Coaxitron® control, connect the control wiring to RXD+
and RXD-.
From controller
To 4-wire terminal inside back box
TXD+
TXD-
RXD+
RXD-
Proceed to Section 3.3, DOME DRIVE INSTALLATION.
12
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table A. Video Coaxial Cable Requirements
Cable Type*
Maximum Distance
RG59/U
RG6/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
RG11/U
* Minimum cable requirements:
75 ohms
All-copper center conductor
All-copper braided shield with 95% braid coverage
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC applications
and are calculated with a 10-percent voltage drop. (10-percent is generally the
maximum allowable voltage drop for AC-powered devices.)
Wire Gauge
EXAMPLE: An enclosure that re-
quires 80 vA and is installed 35 feet
(10 m) from the transformer would
require a minimum wire gauge of 20
Awg.
20
18
16
14
12
10
10
20
30
40
50
60
70
80
90
283 451 716 1142 1811 2880
(86) (137) (218) (348) (551) (877)
141 225 358
(42) (68) (109) (174) (275) (438)
571 905 1440
94 150 238 380 603 960
(28) (45) (72) (115) (183) (292)
NOTE: Distances are calculated in
feet; values in parentheses are
meters.
70
112 179
285 452 720
(86) (137) (219)
(21) (34) (54)
56 90 143
(17) (27) (43)
47 75 119
(14) (22) (36)
40 64 102
(12) (19) (31)
35 56 89
(10) (17) (27)
228 362 576
(69) (110) (175)
190 301 480
(57) (91) (146)
163 258 411
(49) (78) (125)
142 226 360
(43) (68) (109)
31
(9)
50
79
126 201 320
(38) (61) (97)
(15) (24)
100 28
(8)
45 71
(13) (21)
41 65
(12) (19)
37 59
(11) (17)
34 55
(10) (16)
32 51
(9) (15)
30 47
(9) (14)
28 44
(8) (13)
26 42
(7) (12)
25 39
(7) (11)
23 37
(7) (11)
22 35
(6) (10)
114 181 288
(34) (55) (87)
110 25
(7)
103 164 261
(31) (49) (79)
120 23
(7)
95
150 240
(28) (45) (73)
130 21
(6)
87 139 221
(26) (42) (67)
81 129 205
(24) (39) (62)
76 120 192
(23) (36) (58)
71 113 180
(21) (34) (54)
67 106 169
(20) (32) (51)
63 100 160
(19) (30) (48)
60 95 151
(18) (28) (46)
57 90 144
(17) (27) (43)
140 20
(6)
150 18
(5)
160 17
(5)
170 16
(4)
180 15
(4)
190 14
(4)
200 14
(4)
Pelco Manual C454M-C (1/98)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 3. 24 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)
14
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 4. 120 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)
Pelco Manual C454M-C (1/98)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5. 230 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)
16
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.2 Hard-Wire or Remote Receiver/Driver
Refer to Figures 6 and 7 for wiring diagrams.
Refer to Table A for the type of video coaxial cable to use.
On models for suspended ceilings or hard ceilings, a plate is provided on the top of
the back box with 1/2" and 3/4" conduit knockouts.
If your back box has a power switch, make sure it is off before wiring power to the
back box.
A minimum of eleven (11) conductors plus coax are required for pan/tilt, motorized
zoom lens and camera power. Dome drives with presets (PP) require an additional
six (6) conductors for Type D or seven (7) conductors for Type E. The above does
not include the conductor requirements for heaters/blower which will need an addi-
tional two (2) plus ground.
The following cable distances are approximate and does not account for heaters/
blower.
Calculations are based on a 10% cable loss with both motors running.
Dome Drive
Type B & C
Type D
Model Type
Non-Preset Models
11 Conductors
12 Conductors*
Preset Non-SL Models
17 Conductors 18 Conductors*
Preset SL Models
Type E
18 Conductors
19 Conductors*
20 Awg
18 Awg
16 Awg
153 ft (46.6 m)
244 ft (74.3 m)
387 ft (117.9 m)
281 ft (85.6 m)
447 ft (136.2 m)
710 ft (216.4 m)
* Using 2-conductor common.
A relay box (RB24) for use with a hardwire control only is available to extend the
operating distance (control to relay box) up to 15,000 ft over 18 Awg wire.
The following cable sizes are the minimum recommended for use with the heaters/
blower kit at the wattage and voltage listed.
122 watts @ 24 VAC
20 Awg
18 Awg
16 Awg
23 ft
37 ft (11.2 m)
58 ft (17.6 m)
(7 m)
127 watts @ 120 VAC
20 Awg
18 Awg
16 Awg
558 ft (170 m)
888 ft (270.6 m)
1,410 ft (429.7 m)
129 watts @ 230 VAC
20 Awg
18 Awg
16 Awg
2,020 ft (615.7 m)
3,213 ft (979.3 m)
5,100 ft (1,554.4 m)
Proceed to Section 3.3, DOME DRIVE INSTALLATION.
Pelco Manual C454M-C (1/98)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: For fixed mount or dome drive with blower/heaters and without integral receiver/driver.
Figure 6. Wiring Diagram, Hard-Wire Control with Heater
18
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: For use in domes without integral receiver/driver or heaters and blower.
Figure 7. Wiring Diagram, Hard-Wire Control without Heater
Pelco Manual C454M-C (1/98)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2.3 Heater/Blower Kit Field Installation
The kits are shipped partially assembled, to complete assembly and to install the
heater/blower kit perform the following steps:
1. Place the fan over the four (4) unused internally threaded standoffs located on
the back plate (refer to Figure 11). Note the arrow indicating the air flow direc-
tion of the fan, installing with arrow pointing “away” from back plate.
2. Place the heater assembly over the fan aligning the four (4) holes in the plate
with the holes in the fan and the standoffs.
3. Install the four (4) #6 lock washers and screws through the plate and the fan
threading the screws into the standoffs.
4. Mounting through one hole of the thermostat mounting tab, attach the thermo-
stat to the standoff of the terminal block on the end nearest the fan using the 6-
32 x 3/8" screw (see Figure 11).
5. Connect the terminated wires to the terminal block as shown in Figures 3
through 6 depending on back box configuration.
3.3 DOME DRIVE INSTALLATION
Back box installation is now complete. Proceed with the installation of the dome
drive or fixed mount unit. Refer to the manual provided with the dome drive or fixed
mount for further installation instructions.
20
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 EXPLODED ASSEMBLY DIAGRAMS
Figure 8. Suspended Ceiling Back Box Exploded Assembly Diagram
Table C. Suspended Ceiling Back Box Exploded Assembly Parts List
Item
Quantity
Description
Part Number
1
2
3
4
5
6
1
1
1
1
4
4
1
1
Trim ring, white
Back box
SB262ASSY
8144287COMP
8144169COMP
8004130COMP
PT180410001
80010008
Faceplate, drop ceiling, white
Plate, gland
Receiver, ball stud
Clip, T-rail retaining
Switch, rocker, on/off, SPST (not shown)
Acrylic dome, clear (not shown)
Acrylic dome, smoked (not shown)
Dome gasket (not shown)
SWI0201S11N41P
81410001-5
81410001-4
1
94510031
A
B
C
D
E
F
4
4
8
8
2
2
Screw, 1/4-20 x 3/8", pan head, Phillips
Washer, split lock, 1/4"
Nut, 6-32
ZH1/420X.375SPP
ZH1/4LWSSL
ZH6-32NUTSH
ZH6LWSIS
Washer, internal star, #6
Bolt, eye, 1/4-20 x 2" full thread
Nut, 1/4-20
ZH1/4-20X2.0EYE
ZH1/4-20NUTCH
Pelco Manual C454M-C (1/98)
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 9. Hard Ceiling Back Box Exploded Assembly Diagram
Table D. Hard Ceiling Back Box Exploded Assembly Parts List
Item
Quantity
Description
Part Number
SB262ASSY
1
2
3
4
1
1
1
4
1
1
1
Trim ring, white
Back box
8141202WA
Plate, gland
8004130COMP
PT180410001
SWI0201S11N41P
8004110COMP
81410001-5
Receiver ball stud
Switch, on/off, SPST (not shown)
Backup plate, optional (not shown)
Acrylic dome, clear (not shown)
Acrylic dome, smoked (not shown)
Dome gasket (not shown)
81410001-4
1
94510031
A
B
4
4
1
4
Screw, 1/4-20 x 3/8", Phillips pan head
Washer, split lock, 1/4"
ZH1/420X.375SPP
ZH1/4LWSSL
Backup plate, optional (not shown)
Screw, 6-32 x 2", Phillips pan head (not shown)
8004110COMP
ZH6-32X2.00SPP
22
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 10. Pendant Back Box Exploded Assembly Diagram
Table E. Pendant Back Box Exploded Assembly Part List
Description
Item
1
Quantity
1
Part Number
Bezel, black
8144190BCOMP
8144190GCOMP
8144185BCOMP
8144185GCOMP
8144984COMP
8144884COMP
8004053COMP
SPA3109
Bezel, gray
2
3
1
1
Back box, pendant, black
Back box, pendant, gray
Cap, pendant, 14", black
Cap, pendant, gray
4
5
3
3
3
1
1
2
1
1
1
Pin, bezel attachment
Spacer, flanged, nylon, 1/4" CLR x 7/16"L
Spring, compression
6
SPRG10000
7
Flange, 1-1/2" NPT
MRCA4000COMP
80010198
8
Gasket (outdoor models only)
O-ring (outdoor models only)
Cable, safety
9
80010010
10
11
E7081002COMP
SWI0201S11N41P
81410001-5
Switch, on/off, SPST (not shown)
Acrylic dome, clear (not shown)
Acrylic dome, smoked (not shown)
Dome gasket (not shown)
Back box gasket (not shown)
81410001-4
1
1
94510031
EH450010000
A
B
4
3
Screw 1/4-20 x 5/8" flat hd phil, M/S, SS
Screw 6-32 x 1/4" hex soc hd C/S, SS
ZH1/420X.625SFS
ZH6-32X.250SS
Pelco Manual C454M-C (1/98)
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 11. Back Plate Exploded Assembly Diagram
24
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table F. Back Plate Exploded Assembly Parts List (Figure 11)
Item
Quantity
Description
Part Number
1
2
2
2
2
1
1
2
1
2
1
1
3
1
1
2
2
2
1
6
1
1
1
1
1
1
1
1
Latch backup plate
8004244COMP
8004105COMP
Latch
3
Latch bracket
8004143COMP
TRF21243.30.70F
CON10P025Z41T
ZH208211-4
4
Transformer (120 VAC model only)
25-position connector plug
Screw, 6-32
5
6
7
10-position terminal block
Alignment pin
TRB6TBV-10-OE
8004402COMP
8004118COMP
EH4600115W3
HTR50120
8
9
Heater/fan mounting bracket
Fan, 120 VAC
10
11
12
13
14
15
16
17
18
19
20
22
23
Heater, 120 VAC
Back plate
8004190COMP
8004046COMP
8004047COMP
80010007
Connector mounting bracket
Stabilizer bracket
Boot
Hairpin clip
ZH1/4CLIPSS
CON01J002Z41S
TRBJ6-2
Connector, BNC jack, insulated
2-position jumper
10-position terminal block cover
Thermostat (units with heaters and blower)
4-position terminal block
Fuse holder
TRBTC6-10-PFH
EH5510049A
TRB4-140
FUS357001
Fuse, 2A 3AG (not shown)
Capacitor, .47 µF, 12 V (not shown)
Capacitor, 220 µF, 100 V (not shown)
Capacitor, 270 µF, 100 V (not shown)
FUS2
CAPE474P012MAY
CAPF221P100JRN
CAPF271P100JRN
A
B
C
D
E
F
G
I
4
4
Screw, 10-32 x 1/2" flat head, Phillips
Split lock washer, 1/4"
ZH10-32X.500CFS
ZH1/4LWSSL
4
Nut, 1/4-20
ZH1/4-20NUTCH
SPA8540
10
2
Spacer .312 OD x 1/8" long, #10
Internal star washer, #10
ZH10LWSIS
2
Screw, 10-32 x 1" pan head, Phillips
Nut, 6-32
ZH10-32X1.00SPP
ZH6-32NUTSH
ZH6-32X.375SPP
ZH6-32X2.00SPS
SPA9401L
2
2
Screw, 6-32 x 3/8" pan head, Phillips
Screw, 6-32 x 2" pan head, Phillips
Spacer, 3/16" hex by 3/4" long, 2-56 tapped
Screw, 10-32 x 1/2" pan head, Phillips
Spacer, 1/4" hex by 1/2" long, 6-32 tapped
Screw, 6-32 x 5/8" flat head, Phillips
Screw, 6-32 x 1/2" pan head, Phillips
J
4
K
L
6
4
ZH10-32X.500SPP
SPA8423
M
N
O
2
2
ZH6-32X.625SFS
ZH6-32X.500SPP
4
Pelco Manual C454M-C (1/98)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
5.0 SPECIFICATIONS
ELECTRICAL
NOTE: It is not recommended using
24 VAC in applications requiring heat-
ers/blower because of the excessive
current draw that may exceed Class
2 transformer applications.
Enclosure Back Box
Input Voltage:
24 VAC or 120 VAC
Power Requirements
Receiver/Driver:
48 vA for 24 VAC and 120 VAC dome drives
Blower
continuous duty:
One (1) at 30 cfm, 1.92 watts, 24 VDC
One (1) at 33 cfm, 6.7 watts, 120 VAC 60 Hz
One (1) at 27 cfm, 8.9 watts 230 VAC 50 Hz
Heaters
24 VAC:
120 VAC:
230 VAC:
120 watts total
135 watts total
105 watts total
Thermostatically controlled; activates ON at 40°F (4.4°C) and
OFF at 60°F (15.56°C)
Power cord:
Power cable:
Not supplied; use 3-wire grounded, 18 Awg minimum for 120 or
230 VAC supply input
Not supplied: must conform to local and national electrical
codes
GENERAL
Enclosure
Environment:
Dimensions:
Indoor or outdoor (depending on model ordered)
See Figures 12 and 13
Construction
Back box:
Cap:
Aluminum
Aluminum
Bezel:
Aluminum
Trim Ring:
ABS/aluminum
Finish:
The following are standard colors; consult factory for optional
colors
Outdoor
Pendant
Light gray
Indoor
Suspended/
Hard Ceiling
White (back box) and eggshell white (faceplate, trim ring and
bezel)
Black
Pendant
Temperature Range
Indoor models: 32° to 120°F (0° to 48.89°C)
Outdoor models: -10° to 120°F (-23.33° to 48.89°C)
(Design and product specifications subject to change without notice.)
26
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
Figure 12. Suspended/Hard Ceiling Dimension Drawings
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
Figure 13. Pendant-Mount Dimension Drawing
Pelco Manual C454M-C (1/98)
27
Download from Www.Somanuals.com. All Manuals Search And Download.
6.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X,
CC3751H-2,CC3651H-2X,MC3651H-2,andMC3651H-2Xcameramodels,whichhaveafive-
year warranty.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed
dome products.
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
Sixmonthsonallpanandtilts,scannersorpresetlensesusedincontinuousmotionapplications
(that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment.
AllgoodsrequiringwarrantyrepairshallbesentfreightprepaidtoPelco,Clovis,California.Repairs
made necessary by reason of misuse, alteration, normal wear, or accident are not covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the
specific use or application made of the Products. Pelco’s liability for any claim, whether based on
breach of contract, negligence, infringement of any rights of any party or product liability, relating
totheProductsshallnotexceedthepricepaidbytheDealertoPelcoforsuchProducts. Innoevent
will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss
of profit and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
Ifawarrantyrepairisrequired, theDealermustcontactPelcoat(800) 289-9100or(559)292-1981
to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty
conditions stated above, please include a written explanation with the product when returned.
Methodofreturnshipmentshallbethesameorequaltothemethodbywhichtheitemwasreceived
by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800)
289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit,
and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number
and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed
to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco, the Pelco logo, Camclosure, Esprit,
Genex, Legacy, and Spectra are registered
trademarks of Pelco.
Pelco c/o Expeditors
473 Eccles Avenue
Endura and ExSite are trademarks of Pelco.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
© Copyright 1998, Pelco. All rights reserved.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
28
Pelco Manual C454M-C (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
|