LIST OF ILLUSTRATIONS  
Figure  
Page  
1
2
3
“T-Bar” Clip Installation .......................................................................9  
Backup Plate Installation...................................................................11  
24 VAC Back Box Wiring Diagram  
(for Dome Drives with Integral Receiver/Driver) ................................14  
120 VAC Back Box Wiring Diagram  
(for Dome Drives with Integral Receiver/Driver) ................................15  
230 VAC Back Box Wiring Diagram  
4
5
(for Dome Drives with Integral Receiver/Driver) ................................16  
Wiring Diagram, Hard-Wire Control with Heater ...............................18  
Wiring Diagram, Hard-Wire Control without Heater ..........................19  
Suspended Ceiling Back Box Exploded Assembly Diagram.............21  
Hard Ceiling Back Box Exploded Assembly Diagram .......................22  
Pendant Back Box Exploded Assembly Diagram..............................23  
Back Plate Exploded Assembly Diagram ..........................................24  
Suspended/Hard Ceiling Dimension Drawings .................................27  
Pendant-Mount Dimension Drawing .................................................27  
6
7
8
9
10  
11  
12  
13  
LIST OF TABLES  
Table  
Page  
A
B
C
D
E
F
Video Coaxial Cable Requirements .................................................13  
24 VAC Wiring Distances ..................................................................13  
Suspended Ceiling Back Box Exploded Assembly Parts List ...........21  
Hard Ceiling Back Box Exploded Assembly Parts List......................22  
Pendant Back Box Exploded Assembly Part List ..............................23  
Back Plate Exploded Assembly Parts List (Figure 11)......................25  
REVISION HISTORY  
Manual #  
C454M  
Date  
Comments  
Original version.  
C454M-A  
6/95  
Revised to incorporate B.O.M. quantity changes as per  
ECO# 94-445. Added 4-position terminal block information  
as per ECO# 94-042. Incorporated new “Front” labeling  
to B.O.M. as per ECO# 94-192. Updated manual to new  
style standards. Added manual revision history.  
6/23/95  
Addendum. Incorporated new fuse and fuse holder into  
wiring diagrams and exploded view diagram as per  
ECO# 95-063.  
2/27/96  
4/96  
Addendum. Section 5.0 Mechanical Parts List revised.  
C454M-B  
C454M-C  
Rev. B. Added Section 3.4.2.1 and Figure 16 per ECO#  
96-061. Changed heater specifications.  
1/98  
Changed manual to new format and manual pagination.  
Reduced number of models. Revised installation  
instructions. Updated exploded assembly diagrams and  
parts lists.  
Pelco Manual C454M-C (1/98)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
(This page intentionally left blank.)  
4
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.0 GENERAL  
1.1 IMPORTANT SAFEGUARDS AND WARNINGS  
Prior to installation and use of this product, the following WARNINGS should be  
observed.  
1. Installation and servicing should only be done by Qualified Service Personnel  
and conform to all Local codes.  
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or  
6P enclosure, it is designed for indoor use only and it must not be installed  
where exposed to rain and moisture.  
3. Only use replacement parts recommended by Pelco.  
4. After replacement/repair of this unit’s electrical components, conduct a resis-  
tance measurement between line and exposed parts to verify the exposed  
parts have not been connected to line circuitry.  
5. The installation method and materials should be capable of supporting four  
(4) times the weight of the enclosure, pan/tilt, camera and lens combination.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage constituting a  
risk of electric shock is present within this unit.  
This symbol indicates that there are important operating and  
maintenance instructions in the literature accompanying this  
unit.  
CAUTION:  
RISK OF  
ELECTRIC SHOCK.  
DO NOT OPEN.  
CAUTION:  
TO REDUCE THE RISK OF ELECTRICAL SHOCK,  
DO NOT REMOVE COVER. NO USER-  
SERVICEABLE PARTS INSIDE. REFER SERVICING  
TO QUALIFIED SERVICE PERSONNEL.  
Please thoroughly familiarize yourself with the information  
in this manual prior to installation and operation.  
Pelco Manual C454M-C (1/98)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2 UNPACKING INSTRUCTIONS  
Unpack and inspect all parts carefully.  
Be sure to save the shipping carton and any inserts. They are the safest material in  
which to make future shipments.  
If an item appears to have been damaged in shipment, replace it properly in its  
carton and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replace-  
ment. (International customers fax 1-559-348-1120 for authorization and instruc-  
tions.)  
If an item needs to be returned to the factory for repair, consult the WARRANTY  
AND RETURN section of this manual for instructions.  
The following items are supplied:  
Suspended Ceiling Models  
1
1
Back box with face plate, trim ring, and dome  
Parts bag  
2
4
Eye bolts with nuts, flat washers and split lock washers  
T-rail clips  
1
Installation/Operation Manual (C454M-C)  
Hard Ceiling Models  
1
1
Back box with trim ring and dome  
Installation/Operation Manual (C454M-C)  
Pendant Models  
1
1
1
1
1
1
Bezel with dome  
Pendant cap  
Back box  
Back box gasket  
Parts bag with two O-rings (outdoor models only)  
Installation/Operation Manual (C454M-C)  
1.3 RECOMMENDED TOOLS  
Pelco does not supply basic tools needed for the installation process. The following  
tools are recommended:  
Medium Phillips screwdriver  
Wire cutter  
Wire stripper  
BNC crimp tool  
Coaxial cable stripper  
Hammer and punch (suspended ceiling model only)  
Large Phillips screwdriver (suspended ceiling model only)  
11 mm wrench (suspended ceiling model only)  
Drill (hard ceiling models only)  
6
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.0 DESCRIPTION  
The BB14 Series of back boxes is part of the IDS14 Intercept® Series of domes.  
The IDS14 Series is an integral system that includes a back box (BB14), dome  
drive or fixed mount (DD14), and dome receiver/driver (DRD14).  
This manual cover the BB14 Series of back boxes. For installation and operation  
instructions for the dome drive, refer to manual C458M-B; for the fixed mount, refer  
to C291M-B; and for the dome receiver/driver, refer to C466M-E.  
2.1 MODELS  
Indoor, Suspended-Grid Ceiling  
BB14A100  
BB14A101  
BB14A110  
BB14A111  
BB14A120  
BB14A121  
BB14A130  
BB14A131  
Indoor back box for suspended-grid ceiling; smoked dome;  
hard-wire control. (CE)  
Indoor back box for suspended-grid ceiling; clear dome; hard-  
wire control. (CE)  
Indoorbackboxforsuspended-gridceiling; smokeddome;120  
VAC input. (UL)  
Indoor back box for suspended-grid ceiling; clear dome; 120  
VAC input. (UL)  
Indoor back box for suspended-grid ceiling; smoked dome; 24  
VAC input. (CE, UL)  
Indoor back box for suspended-grid ceiling; clear dome; 24  
VAC input. (UL)  
Indoorbackboxforsuspended-gridceiling; smokeddome;230  
VAC input. (CE)  
Indoor back box for suspended-grid ceiling; clear dome; 230  
VAC input. (CE)  
Indoor, Hard Ceiling  
Indoor back box for hard ceiling; smoked dome; hard-wire  
BB14C100  
BB14C101  
BB14C110  
BB14C111  
BB14C120  
BB14C121  
BB14C130  
BB14C131  
control. (CE, UL)  
Indoor back box for hard ceiling; clear dome; hard-wire control.  
(CE, UL)  
Indoorbackboxforhardceiling; smokeddome;120VACinput.  
(UL)  
Indoor back box for hard ceiling; clear dome; 120 VAC input.  
(UL)  
Indoor back box for hard ceiling; smoked dome; 24 VAC input.  
(CE, UL)  
Indoor back box for hard ceiling; clear dome; 24 VAC input.  
(CE, UL)  
Indoorbackboxforhardceiling; smokeddome;230VACinput.  
(CE)  
Indoor back box for hard ceiling; clear dome; 230 VAC input.  
(CE)  
Pelco Manual C454M-C (1/98)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Indoor, Pendant  
BB14E100  
Indoor, black, pendant-mount back box; smoked dome; hard-  
wire control. (CE, UL)  
BB14E101  
BB14E110  
BB14E111  
BB14E120  
BB14E121  
BB14E130  
BB14E131  
Indoor, black, pendant-mount back box; clear dome; hard-wire  
control. (CE, UL)  
Indoor, black, pendant-mount back box; smoked dome; 120  
VAC input. (UL)  
Indoor, black, pendant-mount back box; clear dome; 120 VAC  
input. (UL)  
Indoor, black, pendant-mount back box; smoked dome; 24  
VAC input. (CE, UL)  
Indoor, black, pendant-mount back box; clear dome; 24 VAC  
input. (CE, UL)  
Indoor, black, pendant-mount back box; smoked dome; 230  
VAC input. (CE)  
Indoor, black, pendant-mount back box; clear dome; 230 VAC  
input. (CE)  
Outdoor, Pendant  
Outdoor, gray, pendant-mount back box; smoked dome; hard-  
BB14E200  
BB14E200-2  
BB14E200-3  
BB14E201  
BB14E201-2  
BB14E201-3  
BB14E210  
BB14E211  
BB14E220  
BB14E221  
BB14E230  
BB14E231  
wire control. Includes 120 VAC heater and blower. (CE)  
Outdoor, gray, pendant-mount back box; smoked dome; hard-  
wire control. Includes 24 VAC heater and blower. (CE)  
Outdoor, gray, pendant-mount back box; smoked dome; hard-  
wire control. Includes 230 VAC heater and blower. (CE)  
Outdoor,gray,pendant-mountbackbox;cleardome;hard-wire  
control. Includes 120 VAC heater and blower. (CE)  
Outdoor, gray, pendant-mount back box; smoked dome; hard-  
wire control. Includes 24 VAC heater and blower. (CE)  
Outdoor, gray, pendant-mount back box; smoked dome; hard-  
wire control. Includes 230 VAC heater and blower. (CE)  
Outdoor, gray, pendant-mount back box; smoked dome; 120  
VAC input. Includes 120 VAC heater and blower. (UL)  
Outdoor, gray, pendant-mount back box; clear dome; 120 VAC  
input. Includes 120 VAC heater and blower. (UL)  
Outdoor, gray, pendant-mount back box; smoked dome; 24  
VAC input. Includes 24 VAC heater and blower. (CE, UL)  
Outdoor, gray, pendant-mount back box; clear dome; 24 VAC  
input. Includes 24 VAC heater and blower. (CE, UL)  
Outdoor, gray, pendant-mount back box; smoked dome; 230  
VAC input. Includes 230 VAC heater and blower. (CE)  
Outdoor, gray, pendant-mount back box; clear dome; 230 VAC  
input. Includes 230 VAC heater and blower. (CE)  
8
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.0 INSTALLATION  
3.1 MOUNTING  
NOTE: If you are going to install a  
heater/blower kit, it should be done  
before installing the back box. Refer  
to Section 3.2.3, HEATER/BLOWER  
KIT FIELD INSTALLATION.  
The Intercept® Series of domes provide back box configurations for several applica-  
tions and environments (refer to Figures 12 and 13).  
Installation instructions for the applications listed below will appear in the following  
order:  
1. Suspended ceiling mounting  
2. Hard ceiling mounting  
3. Pendant mounting  
3.1.1 Suspended Ceiling Mounting  
To mount the back box into a suspended ceiling grid, perform the following steps:  
NOTE: When installing into a 2' x 4'  
(.61 m x 1.22 m) ceiling grid, cut the  
ceiling tile in half and install an addi-  
tional “T” rail for support.  
1. Determine the location for mounting the back box and remove the appropriate  
ceiling tile.  
2. Angle the back box through the grid opening and set the box into the grid.  
3. From an opening in a grid adjacent to the back box apply the four (4) clips  
supplied to the “T” bar to secure the back box to the grid (refer to Figure 1).  
4. If additional support is required (such as anchoring with a chain or steel cable  
to a support beam above the dome enclosure), install one or both of the 1/4-20  
eye bolts and washers that are supplied in the parts bag:  
a. Remove one or two of the 1/4-20 screws in the top of the back box.  
b. Screw a nut about a half inch onto an eyebolt.  
c. Slide a split lock washer and flat washer onto the eyebolt.  
d. Screw the eyebolt into the back box and lock the eyebolt into place by  
tightening the nut with an 11 mm wrench.  
e. Repeat steps b-d if you are going to install the second eyebolt.  
f.  
Use a chain or cable to fasten the eyebolt(s) to a support structure in the  
ceiling.  
Figure 1. “T-Bar” Clip Installation  
Proceed to Section 3.2, WIRING INSTRUCTIONS.  
Pelco Manual C454M-C (1/98)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.2 Hard Ceiling Mounting  
For installing the back box in a hard ceiling, an optional backup plate is provided for  
applications where additional reinforcement to the ceiling structure is needed.  
To mount the back box directly into a hard ceiling, perform the following steps.  
1. Determine the location of the back box. Ideally the back box cutout should be  
adjacent to any ceiling structure.  
2. Cut the opening in the ceiling (16-13/16" in diameter).  
3. Insert the back box into the opening. Mark spots to drill holes through the side  
of the back box at the locations where fasteners need to be located. Remove  
the back box and drill the holes.  
4. Using the appropriate fasteners (not supplied) attach the back box to any  
adjacent structure through the drilled holes in the box.  
Proceed to Section 3.2, WIRING INSTRUCTIONS.  
3.1.2.1 Optional Backup Plate Installation  
A backup plate assembly is supplied with all back boxes to be installed in hard  
ceilings, and is for use in applications where additional reinforcement to the ceiling  
structure is needed. To install the backup plate, do steps 1 through 2 in Section  
3.1.2 and then proceed as follows. Refer to Figure 2.  
1. Insert the back box into the opening in the ceiling and mark the ceiling with the  
locations of four of the screw holes in the flange. The holes must be 90° apart.  
2. Remove the back box and drill 13/64" screw holes in the ceiling at the marked  
points.  
3. Insert the two (2) pieces of the backup plate through the large hole and posi-  
tion them around the opening. Connect the two halves using the studs pro-  
vided.  
4. Align the nuts in the plate with the four (4) screw holes in the ceiling.  
5. Insert the back box into the ceiling, and align the screw holes in the ceiling  
with the holes in the flange of the back box.  
6. Attach the back box to the backup plate with four (4) 6-32 screws provided.  
7. Use appropriate fasteners (not supplied) to attach the back box to any adja-  
cent structure through the holes drilled in the side of the back box.  
Proceed to Section 3.2, WIRING INSTRUCTIONS.  
10  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.1.3 Pendant Mounting  
The pendant back box is designed to be suspended from a suitable length of 1-1/2”  
pipe threaded at both ends. This pipe can be interfaced to the IWM Series or IDM4018  
wall mounts or to the MRWA wall adapter mount or MRCA ceiling adapter mount.  
To install the pendant type back box, perform the following steps:  
NOTE: The length of pipe used may  
effect noticeable motion on the video  
display. If this occurs additional sup-  
port of the pipe by bracing, guy wir-  
ing, etc. will be required.  
1. Select and install the mount of choice according to the instructions provided  
with the mount. This may be a good time to route any needed wiring through  
the mount. Refer to Section 3.2, WIRING INSTRUCTIONS.  
2. Select the appropriate length of pipe (2-1/2" minimum length) and thread into  
the mount. Tighten to approximately 30 ft/lb and tighten any locking means  
that may be provided on the mount.  
NOTE: For outdoor models apply  
pipe thread sealant to the pipe threads  
prior to assembly.  
3. Slide the back box “cap” up the pipe.  
On outdoor units first slide one (1) of the two (2) O-rings up the pipe, followed  
by the “cap” and the second O-ring.  
On indoor models while holding the “cap” in place, bring the back box into  
place and engage the threaded flange on the back box with the pipe. (Be sure  
to back out the locking screw in the flange prior to this.)  
4. Spin the back box onto the pipe. The latches inside the back box may be used  
as handles to provide a light torque to the box (approximately 20 ft/lb). Tighten  
the lock screw.  
5. Lower the “cap” onto the top of the back box. On outdoor models also lower  
the external O-ring until it contacts the “cap”.  
Proceed to Section 3.2, WIRING INSTRUCTIONS.  
Figure 2. Backup Plate Installation  
Pelco Manual C454M-C (1/98)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2 WIRING INSTRUCTIONS  
How your back box will be wired depends on the type of unit you have:  
Units with an on-board receiver/driver  
Units without an on-board receiver/driver (hard-wire applications)  
Hardwire refers to installations using a remote receiver/driver or a true hardwire  
controller.  
Proceed to either Section 3.2.1, On-Board Receiver/Driver, or Section 3.2.2,  
Hardwire or Remote Receiver/Driver.  
3.2.1 On-Board Receiver/Driver  
On models for suspended ceilings or hard ceilings, a plate is provided on the top of  
the back box with 1/2" and 3/4" conduit knockouts.  
1. Bring the wiring to the back box.  
Video - Refer to Table A for the type of video coaxial cable to use.  
Power - If the input power to the dome is 24 VAC, refer to Table B to determine  
the size of wire to use. For outdoor units, make sure the wiring can supply  
power for the heaters and fan as well as the receiver/driver. Refer to Section  
5.0, SPECIFICATIONS, for power requirements.  
Control - If you are using a Coaxitron® controller, the control signals to operate  
the dome drive will be transmitted over the video coax.  
If you are not using a Coaxitron® controller, bring wires to the back box for two  
(2) RS-485 control lines (RX+ and RX-).  
Refer to Figure 3, 4, or 5 for the following steps.  
2. Install the coaxial cable to the BNC connector.  
3. Install power to the 10-position terminal block. Make sure the power switch on  
the side of the back box is off.  
4. If you are not using Coaxitron® control, connect the control wiring to RXD+  
and RXD-.  
From controller  
To 4-wire terminal inside back box  
TXD+  
TXD-  
RXD+  
RXD-  
Proceed to Section 3.3, DOME DRIVE INSTALLATION.  
12  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table A. Video Coaxial Cable Requirements  
Cable Type*  
Maximum Distance  
RG59/U  
RG6/U  
750 ft (229 m)  
1,000 ft (305 m)  
1,500 ft (457 m)  
RG11/U  
* Minimum cable requirements:  
75 ohms  
All-copper center conductor  
All-copper braided shield with 95% braid coverage  
Table B. 24 VAC Wiring Distances  
The following are the recommended maximum distances for 24 VAC applications  
and are calculated with a 10-percent voltage drop. (10-percent is generally the  
maximum allowable voltage drop for AC-powered devices.)  
Wire Gauge  
EXAMPLE: An enclosure that re-  
quires 80 vA and is installed 35 feet  
(10 m) from the transformer would  
require a minimum wire gauge of 20  
Awg.  
20  
18  
16  
14  
12  
10  
10  
20  
30  
40  
50  
60  
70  
80  
90  
283 451 716 1142 1811 2880  
(86) (137) (218) (348) (551) (877)  
141 225 358  
(42) (68) (109) (174) (275) (438)  
571 905 1440  
94 150 238 380 603 960  
(28) (45) (72) (115) (183) (292)  
NOTE: Distances are calculated in  
feet; values in parentheses are  
meters.  
70  
112 179  
285 452 720  
(86) (137) (219)  
(21) (34) (54)  
56 90 143  
(17) (27) (43)  
47 75 119  
(14) (22) (36)  
40 64 102  
(12) (19) (31)  
35 56 89  
(10) (17) (27)  
228 362 576  
(69) (110) (175)  
190 301 480  
(57) (91) (146)  
163 258 411  
(49) (78) (125)  
142 226 360  
(43) (68) (109)  
31  
(9)  
50  
79  
126 201 320  
(38) (61) (97)  
(15) (24)  
100 28  
(8)  
45 71  
(13) (21)  
41 65  
(12) (19)  
37 59  
(11) (17)  
34 55  
(10) (16)  
32 51  
(9) (15)  
30 47  
(9) (14)  
28 44  
(8) (13)  
26 42  
(7) (12)  
25 39  
(7) (11)  
23 37  
(7) (11)  
22 35  
(6) (10)  
114 181 288  
(34) (55) (87)  
110 25  
(7)  
103 164 261  
(31) (49) (79)  
120 23  
(7)  
95  
150 240  
(28) (45) (73)  
130 21  
(6)  
87 139 221  
(26) (42) (67)  
81 129 205  
(24) (39) (62)  
76 120 192  
(23) (36) (58)  
71 113 180  
(21) (34) (54)  
67 106 169  
(20) (32) (51)  
63 100 160  
(19) (30) (48)  
60 95 151  
(18) (28) (46)  
57 90 144  
(17) (27) (43)  
140 20  
(6)  
150 18  
(5)  
160 17  
(5)  
170 16  
(4)  
180 15  
(4)  
190 14  
(4)  
200 14  
(4)  
Pelco Manual C454M-C (1/98)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 3. 24 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)  
14  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4. 120 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)  
Pelco Manual C454M-C (1/98)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 5. 230 VAC Back Box Wiring Diagram (for Dome Drives with Integral Receiver/Driver)  
16  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.2 Hard-Wire or Remote Receiver/Driver  
Refer to Figures 6 and 7 for wiring diagrams.  
Refer to Table A for the type of video coaxial cable to use.  
On models for suspended ceilings or hard ceilings, a plate is provided on the top of  
the back box with 1/2" and 3/4" conduit knockouts.  
If your back box has a power switch, make sure it is off before wiring power to the  
back box.  
A minimum of eleven (11) conductors plus coax are required for pan/tilt, motorized  
zoom lens and camera power. Dome drives with presets (PP) require an additional  
six (6) conductors for Type D or seven (7) conductors for Type E. The above does  
not include the conductor requirements for heaters/blower which will need an addi-  
tional two (2) plus ground.  
The following cable distances are approximate and does not account for heaters/  
blower.  
Calculations are based on a 10% cable loss with both motors running.  
Dome Drive  
Type B & C  
Type D  
Model Type  
Non-Preset Models  
11 Conductors  
12 Conductors*  
Preset Non-SL Models  
17 Conductors 18 Conductors*  
Preset SL Models  
Type E  
18 Conductors  
19 Conductors*  
20 Awg  
18 Awg  
16 Awg  
153 ft (46.6 m)  
244 ft (74.3 m)  
387 ft (117.9 m)  
281 ft (85.6 m)  
447 ft (136.2 m)  
710 ft (216.4 m)  
* Using 2-conductor common.  
A relay box (RB24) for use with a hardwire control only is available to extend the  
operating distance (control to relay box) up to 15,000 ft over 18 Awg wire.  
The following cable sizes are the minimum recommended for use with the heaters/  
blower kit at the wattage and voltage listed.  
122 watts @ 24 VAC  
20 Awg  
18 Awg  
16 Awg  
23 ft  
37 ft (11.2 m)  
58 ft (17.6 m)  
(7 m)  
127 watts @ 120 VAC  
20 Awg  
18 Awg  
16 Awg  
558 ft (170 m)  
888 ft (270.6 m)  
1,410 ft (429.7 m)  
129 watts @ 230 VAC  
20 Awg  
18 Awg  
16 Awg  
2,020 ft (615.7 m)  
3,213 ft (979.3 m)  
5,100 ft (1,554.4 m)  
Proceed to Section 3.3, DOME DRIVE INSTALLATION.  
Pelco Manual C454M-C (1/98)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: For fixed mount or dome drive with blower/heaters and without integral receiver/driver.  
Figure 6. Wiring Diagram, Hard-Wire Control with Heater  
18  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: For use in domes without integral receiver/driver or heaters and blower.  
Figure 7. Wiring Diagram, Hard-Wire Control without Heater  
Pelco Manual C454M-C (1/98)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2.3 Heater/Blower Kit Field Installation  
The kits are shipped partially assembled, to complete assembly and to install the  
heater/blower kit perform the following steps:  
1. Place the fan over the four (4) unused internally threaded standoffs located on  
the back plate (refer to Figure 11). Note the arrow indicating the air flow direc-  
tion of the fan, installing with arrow pointing “away” from back plate.  
2. Place the heater assembly over the fan aligning the four (4) holes in the plate  
with the holes in the fan and the standoffs.  
3. Install the four (4) #6 lock washers and screws through the plate and the fan  
threading the screws into the standoffs.  
4. Mounting through one hole of the thermostat mounting tab, attach the thermo-  
stat to the standoff of the terminal block on the end nearest the fan using the 6-  
32 x 3/8" screw (see Figure 11).  
5. Connect the terminated wires to the terminal block as shown in Figures 3  
through 6 depending on back box configuration.  
3.3 DOME DRIVE INSTALLATION  
Back box installation is now complete. Proceed with the installation of the dome  
drive or fixed mount unit. Refer to the manual provided with the dome drive or fixed  
mount for further installation instructions.  
20  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.0 EXPLODED ASSEMBLY DIAGRAMS  
Figure 8. Suspended Ceiling Back Box Exploded Assembly Diagram  
Table C. Suspended Ceiling Back Box Exploded Assembly Parts List  
Item  
Quantity  
Description  
Part Number  
1
2
3
4
5
6
1
1
1
1
4
4
1
1
Trim ring, white  
Back box  
SB262ASSY  
8144287COMP  
8144169COMP  
8004130COMP  
PT180410001  
80010008  
Faceplate, drop ceiling, white  
Plate, gland  
Receiver, ball stud  
Clip, T-rail retaining  
Switch, rocker, on/off, SPST (not shown)  
Acrylic dome, clear (not shown)  
Acrylic dome, smoked (not shown)  
Dome gasket (not shown)  
SWI0201S11N41P  
81410001-5  
81410001-4  
1
94510031  
A
B
C
D
E
F
4
4
8
8
2
2
Screw, 1/4-20 x 3/8", pan head, Phillips  
Washer, split lock, 1/4"  
Nut, 6-32  
ZH1/420X.375SPP  
ZH1/4LWSSL  
ZH6-32NUTSH  
ZH6LWSIS  
Washer, internal star, #6  
Bolt, eye, 1/4-20 x 2" full thread  
Nut, 1/4-20  
ZH1/4-20X2.0EYE  
ZH1/4-20NUTCH  
Pelco Manual C454M-C (1/98)  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 9. Hard Ceiling Back Box Exploded Assembly Diagram  
Table D. Hard Ceiling Back Box Exploded Assembly Parts List  
Item  
Quantity  
Description  
Part Number  
SB262ASSY  
1
2
3
4
1
1
1
4
1
1
1
Trim ring, white  
Back box  
8141202WA  
Plate, gland  
8004130COMP  
PT180410001  
SWI0201S11N41P  
8004110COMP  
81410001-5  
Receiver ball stud  
Switch, on/off, SPST (not shown)  
Backup plate, optional (not shown)  
Acrylic dome, clear (not shown)  
Acrylic dome, smoked (not shown)  
Dome gasket (not shown)  
81410001-4  
1
94510031  
A
B
4
4
1
4
Screw, 1/4-20 x 3/8", Phillips pan head  
Washer, split lock, 1/4"  
ZH1/420X.375SPP  
ZH1/4LWSSL  
Backup plate, optional (not shown)  
Screw, 6-32 x 2", Phillips pan head (not shown)  
8004110COMP  
ZH6-32X2.00SPP  
22  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 10. Pendant Back Box Exploded Assembly Diagram  
Table E. Pendant Back Box Exploded Assembly Part List  
Description  
Item  
1
Quantity  
1
Part Number  
Bezel, black  
8144190BCOMP  
8144190GCOMP  
8144185BCOMP  
8144185GCOMP  
8144984COMP  
8144884COMP  
8004053COMP  
SPA3109  
Bezel, gray  
2
3
1
1
Back box, pendant, black  
Back box, pendant, gray  
Cap, pendant, 14", black  
Cap, pendant, gray  
4
5
3
3
3
1
1
2
1
1
1
Pin, bezel attachment  
Spacer, flanged, nylon, 1/4" CLR x 7/16"L  
Spring, compression  
6
SPRG10000  
7
Flange, 1-1/2" NPT  
MRCA4000COMP  
80010198  
8
Gasket (outdoor models only)  
O-ring (outdoor models only)  
Cable, safety  
9
80010010  
10  
11  
E7081002COMP  
SWI0201S11N41P  
81410001-5  
Switch, on/off, SPST (not shown)  
Acrylic dome, clear (not shown)  
Acrylic dome, smoked (not shown)  
Dome gasket (not shown)  
Back box gasket (not shown)  
81410001-4  
1
1
94510031  
EH450010000  
A
B
4
3
Screw 1/4-20 x 5/8" flat hd phil, M/S, SS  
Screw 6-32 x 1/4" hex soc hd C/S, SS  
ZH1/420X.625SFS  
ZH6-32X.250SS  
Pelco Manual C454M-C (1/98)  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 11. Back Plate Exploded Assembly Diagram  
24  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table F. Back Plate Exploded Assembly Parts List (Figure 11)  
Item  
Quantity  
Description  
Part Number  
1
2
2
2
2
1
1
2
1
2
1
1
3
1
1
2
2
2
1
6
1
1
1
1
1
1
1
1
Latch backup plate  
8004244COMP  
8004105COMP  
Latch  
3
Latch bracket  
8004143COMP  
TRF21243.30.70F  
CON10P025Z41T  
ZH208211-4  
4
Transformer (120 VAC model only)  
25-position connector plug  
Screw, 6-32  
5
6
7
10-position terminal block  
Alignment pin  
TRB6TBV-10-OE  
8004402COMP  
8004118COMP  
EH4600115W3  
HTR50120  
8
9
Heater/fan mounting bracket  
Fan, 120 VAC  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
22  
23  
Heater, 120 VAC  
Back plate  
8004190COMP  
8004046COMP  
8004047COMP  
80010007  
Connector mounting bracket  
Stabilizer bracket  
Boot  
Hairpin clip  
ZH1/4CLIPSS  
CON01J002Z41S  
TRBJ6-2  
Connector, BNC jack, insulated  
2-position jumper  
10-position terminal block cover  
Thermostat (units with heaters and blower)  
4-position terminal block  
Fuse holder  
TRBTC6-10-PFH  
EH5510049A  
TRB4-140  
FUS357001  
Fuse, 2A 3AG (not shown)  
Capacitor, .47 µF, 12 V (not shown)  
Capacitor, 220 µF, 100 V (not shown)  
Capacitor, 270 µF, 100 V (not shown)  
FUS2  
CAPE474P012MAY  
CAPF221P100JRN  
CAPF271P100JRN  
A
B
C
D
E
F
G
I
4
4
Screw, 10-32 x 1/2" flat head, Phillips  
Split lock washer, 1/4"  
ZH10-32X.500CFS  
ZH1/4LWSSL  
4
Nut, 1/4-20  
ZH1/4-20NUTCH  
SPA8540  
10  
2
Spacer .312 OD x 1/8" long, #10  
Internal star washer, #10  
ZH10LWSIS  
2
Screw, 10-32 x 1" pan head, Phillips  
Nut, 6-32  
ZH10-32X1.00SPP  
ZH6-32NUTSH  
ZH6-32X.375SPP  
ZH6-32X2.00SPS  
SPA9401L  
2
2
Screw, 6-32 x 3/8" pan head, Phillips  
Screw, 6-32 x 2" pan head, Phillips  
Spacer, 3/16" hex by 3/4" long, 2-56 tapped  
Screw, 10-32 x 1/2" pan head, Phillips  
Spacer, 1/4" hex by 1/2" long, 6-32 tapped  
Screw, 6-32 x 5/8" flat head, Phillips  
Screw, 6-32 x 1/2" pan head, Phillips  
J
4
K
L
6
4
ZH10-32X.500SPP  
SPA8423  
M
N
O
2
2
ZH6-32X.625SFS  
ZH6-32X.500SPP  
4
Pelco Manual C454M-C (1/98)  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.0 SPECIFICATIONS  
ELECTRICAL  
NOTE: It is not recommended using  
24 VAC in applications requiring heat-  
ers/blower because of the excessive  
current draw that may exceed Class  
2 transformer applications.  
Enclosure Back Box  
Input Voltage:  
24 VAC or 120 VAC  
Power Requirements  
Receiver/Driver:  
48 vA for 24 VAC and 120 VAC dome drives  
Blower  
continuous duty:  
One (1) at 30 cfm, 1.92 watts, 24 VDC  
One (1) at 33 cfm, 6.7 watts, 120 VAC 60 Hz  
One (1) at 27 cfm, 8.9 watts 230 VAC 50 Hz  
Heaters  
24 VAC:  
120 VAC:  
230 VAC:  
120 watts total  
135 watts total  
105 watts total  
Thermostatically controlled; activates ON at 40°F (4.4°C) and  
OFF at 60°F (15.56°C)  
Power cord:  
Power cable:  
Not supplied; use 3-wire grounded, 18 Awg minimum for 120 or  
230 VAC supply input  
Not supplied: must conform to local and national electrical  
codes  
GENERAL  
Enclosure  
Environment:  
Dimensions:  
Indoor or outdoor (depending on model ordered)  
See Figures 12 and 13  
Construction  
Back box:  
Cap:  
Aluminum  
Aluminum  
Bezel:  
Aluminum  
Trim Ring:  
ABS/aluminum  
Finish:  
The following are standard colors; consult factory for optional  
colors  
Outdoor  
Pendant  
Light gray  
Indoor  
Suspended/  
Hard Ceiling  
White (back box) and eggshell white (faceplate, trim ring and  
bezel)  
Black  
Pendant  
Temperature Range  
Indoor models: 32° to 120°F (0° to 48.89°C)  
Outdoor models: -10° to 120°F (-23.33° to 48.89°C)  
(Design and product specifications subject to change without notice.)  
26  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES  
Figure 12. Suspended/Hard Ceiling Dimension Drawings  
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES  
Figure 13. Pendant-Mount Dimension Drawing  
Pelco Manual C454M-C (1/98)  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.0 WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
Exceptions to this warranty are as noted below:  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X,  
CC3751H-2,CC3651H-2X,MC3651H-2,andMC3651H-2Xcameramodels,whichhaveafive-  
year warranty.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed  
dome products.  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
Sixmonthsonallpanandtilts,scannersorpresetlensesusedincontinuousmotionapplications  
(that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment.  
AllgoodsrequiringwarrantyrepairshallbesentfreightprepaidtoPelco,Clovis,California.Repairs  
made necessary by reason of misuse, alteration, normal wear, or accident are not covered under  
this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the  
specific use or application made of the Products. Pelco’s liability for any claim, whether based on  
breach of contract, negligence, infringement of any rights of any party or product liability, relating  
totheProductsshallnotexceedthepricepaidbytheDealertoPelcoforsuchProducts. Innoevent  
will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss  
of profit and claims of third parties) however caused, whether by the negligence of Pelco or  
otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
Ifawarrantyrepairisrequired, theDealermustcontactPelcoat(800) 289-9100or(559)292-1981  
to obtain a Repair Authorization number (RA), and provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under the warranty  
conditions stated above, please include a written explanation with the product when returned.  
Methodofreturnshipmentshallbethesameorequaltothemethodbywhichtheitemwasreceived  
by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800)  
289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit,  
and RA number if returned for repair).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number  
and freight should be prepaid. Ship to the appropriate address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed  
to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco, the Pelco logo, Camclosure, Esprit,  
Genex, Legacy, and Spectra are registered  
trademarks of Pelco.  
Pelco c/o Expeditors  
473 Eccles Avenue  
Endura and ExSite are trademarks of Pelco.  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
© Copyright 1998, Pelco. All rights reserved.  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union  
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.  
28  
Pelco Manual C454M-C (1/98)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Perle Systems Server 5500161 40 User Manual
Philips Car Speaker MMS 305 A 3500 User Manual
Philips DVD Player DVD619 User Manual
Philips Electric Shaver 6828XL User Manual
Plasmon Camcorder LF6600 User Manual
Polaris Lawn Mower S2188 8070PL8C User Manual
Princeton Home Security System PI MAX2 User Manual
Printronix Printer L5020 User Manual
Pro Ject Speaker Strauss User Manual
PYLE Audio Car Amplifier PLMRA120 User Manual