CC3300 Series
1/3-Inch Color Camera
Installation/
Operation Manual
C1900M (4/99)
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
12. Power-Cord Protection - Power supply cords should be
routed so that they are not likely to be walked on or pinched
by items placed upon or against then, paying particular
attention to cords and plugs, convenience receptacles,
and the point where they exit from the appliance.
1.0 IMPORTANT SAFEGUARDS
1. Read Instructions - All the safety and operating instruc-
tions should be read before the unit is operated.
2. Retain Instructions -The safety and operating instructions
should be retained for future reference.
13. Power Lines - An outdoor system should not be located in
the vicinity of overhead power lines or other electric light
or power circuits, or where it can fall into such power lines
or circuits. When installing an outdoor system, extreme
care should be taken to keep from touching such power
lines or circuits as contact with them might be fatal. U.S.A.
models only - refer to the National Electrical Code Article
820 regarding installation of CATV systems.
3. Heed Warnings - All warnings on the unit and in the oper-
ating instructions should be adhered to.
4. Follow Instructions - All operating and use instructions
should be followed.
5. Cleaning - Unplug the unit from the outlet before clean-
ing. Do not use liquid cleaners or aerosol cleaners. Use a
damp cloth for cleaning.
14. Overloading - Do not overload outlets and extension cords
as this can result in a risk of fire or electric shock.
6. Attachments - Do not use attachments not recommended
by the product manufacturer as they may cause hazards.
15. Object and Liquid Entry - Never push objects of any kind
into this unit through openings as they may touch danger-
ous voltage points or short-out parts that could result in a
fire or electric shock. Never spill liquid of any kind on the
unit.
7. Water and Moisture - Do not use this unit near water - for
example, near a bath tub, wash bowl, kitchen sink, or
laundry tub, in a wet basement, near a swimming pool, in
an unprotected outdoor installation, or any area which is
classified as a wet location.
16. Servicing - Do not attempt to service this unit yourself as
opening or removing covers may expose you to danger-
ous voltage or other hazards. Refer all servicing to quali-
fied service personnel.
8. Accessories - Do not place this unit on an unstable stand,
tripod, bracket, or mount. The unit may fall, causing seri-
ous injury to a person and serious damage to the unit.
Use only with a stand, tripod, bracket, or mount recom-
mended by the manufacturer, or sold with the product.
Any mounting of the unit should follow the manufacturer’s
instructions, and should use a mounting accessory rec-
ommended by the manufacturer.
17. Damage Requiring Service - Unplug the unit from the out-
let and refer servicing to qualified service personnel un-
der the following conditions:
a. When the power-supply cord or plug is damaged.
b. If liquid has been spilled, or objects have fallen into
the unit.
An appliance and cart combination should be
moved with care. Quick stops, excessive force,
and uneven surfaces may cause the appliance
and cart combination to overturn.
c. If the unit has been exposed to rain or water.
d. If the unit does not operate normally by following the
operating instructions.Adjust only those controls that
are covered by the operating instructions, as an im-
proper adjustment of other controls may result in
damage and will often require extensive work by a
qualified technician to restore the unit to its normal
operation.
9. Ventilation - Openings in the enclosure, if any, are pro-
vided for ventilation and to ensure reliable operation of
the unit and to protect it from overheating. These open-
ings must not be blocked or covered.This unit should not
be placed in a built-in installation unless proper ventila-
tion is provided or the manufacturer's instructions have
been adhered to.
e. If the unit has been dropped or the cabinet has been
damaged.
f.
When the unit exhibits a distinct change in perfor-
mance - this indicates a need for service.
10. Power Sources - This unit should be operated only from
the type of power source indicated on the marking label.
If you are not sure of the type of power supply you plan to
use, consult your appliance dealer or local power com-
pany. For units intended to operate from battery power,
or other sources, refer to the operating instructions.
18. Replacement Parts - When replacement parts are re-
quired, be sure the service technician has used replace-
ment parts specified by the manufacturer or have the same
characteristics as the original part. Unauthorized substi-
tutions may result in fire, electric shock or other hazards.
19. Safety Check - Upon completion of any service or repairs
to this unit, ask the service technician to perform safety
checks to determine that the unit is in proper operating
condition.
11. Grounding or Polarization - This unit may be equipped
with a polarized alternating-current line plug (a plug hav-
ing one blade wider than the other). This plug will fit into
the power outlet only one way. This is a safety feature. If
you are unable to insert the plug fully into the outlet, try
reversing the plug. If the plug should still fail to fit, contact
your electrician to replace your obsolete outlet. Do not
defeat the safety purpose of the polarized plug.
20. Coax Grounding - If an outside cable system is connected
to the unit, be sure the cable system is grounded. U.S.A.
models only-Section 810 of the National Electrical Code,
ANSI/NFPA No.70-1981, provides information with respect
to proper grounding of the mount and supporting struc-
ture, grounding of the coax to a discharge unit, size of
grounding conductors, location of discharge unit, connec-
tion to grounding electrodes, and requirements for the
grounding electrode.
Alternately, this unit may be equipped with a 3-wire
grounding-type plug, a plug having a third (grounding)
pin. This plug will only fit into a grounding-type power
outlet. This is a safety feature. If you are unable to insert
the plug into the outlet, contact your electrician to replace
your obsolete outlet. Do not defeat the safety purpose of
the grounding-type plug.
21. Lightning - For added protection of this unit during a light-
ning storm, or when it is left unattended and unused for
long periods of time, unplug it from the wall outlet and
disconnect the cable system.This will prevent damage to
the unit due to lightning and power-line surges.
Pelco Manual C1900M (4/99)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
1.2 SAFETY PRECAUTIONS
1.1 FCC INFORMATION
For USA customers
CAUTION
WARNING - This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules.These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a residential installation. This equip-
ment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harm-
ful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of
the following measures:
RISK OF ELECTRIC
SHOCK. DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRI-
CAL SHOCK DO NOT OPEN COVERS. NO USER
SERVICEABLE PARTS INSIDE. REFER SERVIC-
ING TO QUALIFIED SERVICE PERSONNEL.
This label may appear on the bottom of the unit due to space
limitations.
The lightning flash with an arrowhead symbol,
within an equilateral triangle, is intended to alert
the user to the presence of uninsulated “dan-
gerous voltage” within the product’s enclosure
that may be of sufficient magnitude to consti-
tute a risk of electric shock to persons.
-
-
-
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
Consult the dealer or an experienced audio/TV technician
for help.
-
The exclamation point within an equilateral tri-
angle is intended to alert the user to presence
of important operating and maintenance (ser-
vicing) instructions in the literature accompa-
nying the appliance.
Intentional or unintentional changes or modifications not ex-
pressly approved by the party responsible for compliance shall
not be made. Any such changes or modifications could void
the user’s authority to operate the equipment.
WARNING: To prevent fire or shock hazard, do not ex-
pose units not specifically designed for outdoor use to
rain or moisture.
The user may find the following booklet prepared by the Federal
Communications Commission helpful: “How to Identify and Re-
solve Radio-TV Interference Problems”. This booklet is avail-
able from the U.S. Government Printing Office, Washington, DC
20402, Stock No. 004-000-00345-4.
For United Kingdom customers
WARNING
THIS APPARATUS MUST BE EARTHED
IMPORTANT
The wires in the main power lead are colored in accordance
with the following code:
WARNING: Electrostatic-sensitive device. Use proper
CMOS/MOSFET handling precautions to avoid electrostatic
discharge.
Green-and-yellow:
Blue:
Brown:
Earth
Neutral
Live
As the colors of the wires in the power lead of this apparatus
may not correspond with the colored markings identifying the
terminals in your plug proceed as follows:
The wire which is colored green-and-yellow must be connected
to the terminal in the plug which is marked by the letter E or by
NOTE: Grounded wrist straps must be worn and proper
ESD safety precautions observed when handling the elec-
trostatic-sensitive printed circuit boards.
the safety earth symbol
yellow.
or colored green or green-and-
1.3 UNPACKING
The wire which is colored blue must be connected to the termi-
nal which is marked with the letter N or colored black.
The wire which is colored brown must be connected to the
terminal which is marked with the letter L or colored red.
The shipping carton is the safest container in which the unit
may be transported. Save it for possible future use.
Supplied
Accessories:
4-pin plug for auto iris lens (1); Operating
Instructions (1)
4
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 DESCRIPTION
The CC3300 Series cameras are compact, rugged, full performance, general purpose color CCD cameras (see Figure
1). Contemporary styling and controls allow these cameras to blend naturally into the most modern installation sites.
These cameras are 1/3-inch image format and are available in the following models:
NOTE: The alphanumeric reference designations (of the form ) used in this manual are keyed to the reference
A
designations used in the instruction sheets shipped with the product received by the customer.
Model #
CC3300-2
CC3300-2X
CC3300-3
Voltage
Nominal Power
Color Signal Standard
24 VAC
24 VAC
220-240 VAC
3.5 W
3.5 W
4.0 W
NTSC (60 Hz) 330 TVlines
PAL (50 Hz) 330 TV lines
PAL (50 Hz) 330 TV lines
NOTE: Unless otherwise noted, the operating
instructions within this manual are applicable
to all camera models, even though their signal
systems and power requirements are different.
All camera models have the following features:
•
High sensitivity (minimum illumination: 1.0 lux,
f/1.2)
•
•
•
•
•
Backlight compensation
Turbo AGC
CCD IRIS function
Compact and lightweight
Line lock function for synchronizing through AC
power source
•
•
•
C/CS mount capability
DC/VS servo auto-iris lens capability
Automatic tracking white balance
Figure 1. The CC3300 Series Camera
Pelco Manual C1900M (4/99)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1 LOCATION AND FUNCTION OF PARTS
2.1.1 Top/Front/Side (Illustration A )
Lens connector (4-pin socket)
4
When using an auto iris lens, plug the lens into
this socket. The lens cable plug will have to be
replaced with the plug supplied, before insertion.
1
2
3
C/CS adjustment ring (focal length adjustment ring
and locking screw)
Use this ring to adjust the back focus, or focal length
(the distance between the lens mounting plane and
the image plane) – adjusts the back focus to suit
the type of lens fitted. Be sure to use the LOCK
Back focus LOCK screw
5
6
After adjusting the C/CS adjustment ring 1 to
match the type of lens you are using, turn this screw
with a screwdriver to lock the back focus.
LENS mount (C- or CS-mount)
screw
to lock the back focus/focal length.
5
Use to mount an appropriate C-mount or a CS-
mount lens. To attach a C-mount/CS-mount lens,
turn the focal length adjustment ring to the appro-
priate position.
AUTO IRIS select switch
Switch to VIDEO when using a VS-servo lens.
Switch to DC when using a DC-servo lens.
Lens mount cap
Keep in place whenever the lens is not attached to
the camera.
7
NOTE: The camera mounting plate for the
CC3300-2 is on top. The mounting plate for
the CC3300-2X, -3 is on the bottom.
The camera mounting
plate can be attached
to either the top or bot-
L
tom of the camera us-
ing the four attached
screws. Use the mounting plate screw hole to fix
the camera to a mounting bracket. The screw must
be of the following type. 1/4 in. UNC (20 pitch)
Length = 4.5 mm ± 0.2 mm (ISO standard) or
0.197 in. (ASA standard).
A
3
1
2
7
6
5
4
Top/Front/Side View of CC3300 Series Camera
6
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
12
13
BLC compensation ON/OFF switch
2.1.2 Rear (Illustration B )
Set the BLC (backlight compensation) switch to
BLC to compensate for scenes with a strong back
light. The BLC function senses the strength of the
back light and compensates accordingly. Switch-
ing this function on also activates the AGC func-
tion.
IRIS LEVEL L/H adjustment pot
8
This pot can be used to adjust the incident light level
when using the CCD iris or a DC servo lens. Before
leaving the factory, the level is set for the CCD IRIS.
If you wish to use a DC servo lens, turn the adjust-
ment screw towards the H (high) side.
CCD IRIS ON/OFF switch
When switched on (switched to CCD IRIS) this
function automatically adjusts the sensitivity in ac-
cordance with the incident light conditions. Set this
switch to OFF when using an auto-iris lens. The
factory setting is CCD IRIS.
9
V PHASE (vertical phase) ± adjustment pot
Use this pot to compensate for vertical phase dis-
crepancies which can occur when multiple cameras
are connected to a switching device. Each camera’s
output is synchronized to the frequency of the power
supply.
14 VIDEO OUT connector
This coaxial connector (BNC-type) outputs the
video signals.
AGC (automatic gain control) ON/OFF switch
When theAGC is switched on, the signal sensitiv-
ity automatically adjusts to the lighting conditions
of the subject. The switch normally remains in the
AGC position.
10
15 GND (ground) terminal (CC3300-2, -2X only)
Connect this terminal to ground.
16 24 VAC 1 and 2 terminals (CC3300-2, -2X only)
Connect these terminals to a 24 VAC, 50/60 Hz
power supply.
11 Turbo-AGC TURBO/NORM switch
When switched to TURBO, the Turbo-AGC func-
tion gives you a brighter picture under poor light-
ing conditions. Although noise increases slightly,
signal elements are nearly doubled, thereby increas-
ing picture definition. Switching this function on
also activates the AGC function.
Main Power Cable lead (CC3300-3 only)
17
Connect to a 220-240 VAC, 50 Hz power supply.
B
CC3300-2
CC3300-2X
10
CC3300-3
11
12
13
14
14
15
8
9
8
9
16
17
Rear View of CC3300 Series Cameras
Pelco Manual C1900M (4/99)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
The power runs for user-supplied wiring from a 24 VAC
supply to a CC3300-2/CC3300-2X camera should be
within the following limits:
3.0 POWER SUPPLY CONSIDERATIONS
Use only the recommended power supplies. Improper
substitutions may damage the camera or cause a shock
or fire hazard.
Up to 200 ft (60 m) – 18 AWG (1 mm2) or larger.
Up to 325 ft (100 m) – 16 AWG (1.5 mm2) or larger
CC3300-2/CC3300-2X
Do not mistakenly attach the
GND terminal on 24 VAC cam-
eras to either of the power ter-
minal inputs. Be sure to use the
grounding lug or screw.
•
The CC3300-2 must always be operated with a 24
VAC, Class 2 (60 Hz) power supply, while the
CC3300-2X must use a 24 VAC (50 Hz) power
supply. Neither power supply is provided. A wall
transformer (as depicted in Figure 2) is an example
of a common power source.
CC3300-3
•
•
In the USA, use a power supply which is UL Listed.
In Canada, use a power supply which is CSA Cer-
tified.
•
The CC3300-3 must be always operated with a 220-
240 VAC, (50 Hz) power supply.
NOTE:The CC3300-3 is supplied with an at-
tached main power cable cord. See illustration
B and Figure 4 legend for power connections.
When connecting to the transformer, be sure to
carefully connect each lead to the appropriate ter-
minal. Wrong connections may cause malfunction
and/or damage to video camera.
•
•
Ground the unit or an irregular voltage may be
generated in the AC power cord and may cause
malfunction or damage to the video camera.
24 VAC Cameras: Do not exceed 24 VAC in-
put. Normal input voltage is 24 VAC (50/60 Hz).
CC3300-2/CC3300-2X
See Figure 3
Figure 2. Rear Panel: CC3300-2/CC3300-2X
8
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
Typical Power Supply
To 24 VAC Terminals
On Camera
Input
120 VAC, 60 Hz
24 VAC Output
Figure 3. Typical 120 VAC to 24 VAC (60 Hz) Power Supply (CC3300-2 Only)
CC3300-3
POWER CONNECTIONS:
Brown Wire - Hot or Live wire
Blue Wire - Neutral wire
Green and Yellow wire - Earth Ground or GND
Figure 4. Rear Panel: CC3300-3
NOTE: Cameras with 220-240 VAC power
cords are double insulated. Article 250-45 of
the National Electrical Code states that listed
products protected by a system of double insu-
lation shall not be required to be grounded.
Pelco Manual C1900M (4/99)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 LENSES
NOTE: Lenses that are suitable for a 1/3-inch
CCD should be used with this camera using C-
or CS-type lens mounts. Pelco 1/3-inch format
lenses are recommended for optimum perfor-
mance. The use of other lenses may impair cam-
era performance. When lenses for a 2/3-inch or
1/2-inch CCD are used, the viewing angle will
be slightly different.
4.1 LENS LIMITS
Lenses exceeding the dimensions shown in Figure 5
below cannot be used.
When the lens is not mounted on the camera head, be
sure to install the dust cap to protect the internal parts
from dust or damage.
4.2 LENS COMPATIBILITY
(Illustration C )
C
1
The lens must be either a C- or a CS-mount type weigh-
ing less than 2.2 lb (1 kg). The protrusion behind the
mounting surface must be within the following limits:
1)
C-mount lens
1) 3/8 in. (9 mm) or less
2) 5/32 in. (4 mm) or less
1
2
CS-mount lens
2
2)
Compatible Lenses
5/32 in. (4 mm) Max Thread
For CS Lens
7/8 in. (22.4 mm) Max.
Lens
3/8 in. (9 mm) Max.Thread
For C Lens
Figure 5. Standard Acceptable Lens Dimensions
10
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Apply heat to the heat shrink tubing.
4. Put the cover on the plug.
4.3 LENS INSTALLATION
4.3.1 Auto Iris
ILLUSTRATION D ELEMENTS
Install an auto-iris lens as follows:
(Refer to Illustration E )
1
2
3
Cover
1. Unscrew lens mount cap.
Auto-iris cable
2. Screw in the lens.
Rib (If the cable is thick and the plug cover does
not seat properly, cut away this rib.)
NOTE: When attaching a C-mount type lens,
be sure to turn the C/CS adjustment ring fully in
the “C” direction. When the C/CS adjustment
ring is set to “CS,” mounting any lens with a
mount projection of more than 5/32 in. (4 mm)
may damage the internal parts of the camera.
Lens plug
4
D
3. Check the plug wiring on the lens cable against
Illustration D and the pin-outs in step 2 of Section
4.3.2. If you need to replace the existing plug on
the lens cable, follow the instructions given in Sec-
tion 4.3.2.
2
3
1
4. Loosen the back focus LOCK screw. Adjust the
back focus by turning the C/CS adjustment ring in
accordance with the type of lens fitted (C-mount
or CS-mount). Once adjusted, tighten the back fo-
cus LOCK screw. (The factory setting is C-mount.)
1
2
3
For amplified or in-depth back focus adjustment
instructions, see the Information Boxes on pages
13 and 14. General Information, if needed, is pro-
vided on page 12.
4
4
Changing the Plug on an Auto-Iris Lens Cable
4.3.2 Replacing the Auto Iris Lens Cable
Plug (Refer to Illustration D )
4 2
1. Remove the old lens plug from the cable.
Auto-Iris Plug
Pin-out (Back of Plug)
NOTE: Refer to the lens manual to determine
the cable color code.
3 1
2. Remove the plug cover 1 , add heat shrink tubing
to the wires, and solder the lens cable 2 to the
pins 1 thru 4 on the plug supplied. The pin
assignments are as follows:
4.3.3 Manual Iris
Follow the instructions in Section 4.3.1, but ignore all
instructions for changing the lens cable plug.
Pin #
DC-Servo Lens VS-Servo Lens
1
2
Pin 3:
Pin 1:
Drive (+)
Control (-)
Video signal
Power supply
(9 VDC 50 mA)
Pin 2:
Pin 4:
Control (+)
Drive (-)
Not used
Ground
3
4
Pelco Manual C1900M (4/99)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
CAMERA/LENS GEOMETRY–GENERAL INFORMATION
LENS
(STYLIZED)
CAMERA
Incident Light
CCD Iris (Electronic Shutter) CCD out-
put voltage is electronically sampled and
used to adjust for small variations in light
levels. Normally used in indoor, fixed po-
sition applications where small variations
in light levels might be encountered. CCD
iris must be turned OFF when perform-
ing camera/lens adjustments.
CCD
IMAGER
C/CS adjustment (all models) conditions camera mount
for lens type being used by changing physical distance
of imager face with respect to back of lens. Adjustment
screw or ring is initially positioned at the corresponding
C or CS position (corresponding to lens type) and not
some setting in between. Factory set at C position.
C
CS
IRIS
MANUAL
LENS
MOTORIZED
ZOOM LENS
The lens has
a focus ring
adjustment
on it.
Zoom lens which
can be remotely
controlled for zoom
and focus
Iris opening (sometimes referred to as aperture) is
defined by f/stop numbers.The higher the number
the more closed the iris is.
Used when large
variations in lighting
are expected (usually
outside).There are two
types of auto-iris con-
trol:
MOTORIZED IRIS
MANUAL IRIS
AUTO-IRIS
• Iris has motor on it which
is controlled remotely by
the operator
• Iris adjustment ring is
on the lens
• Fixed position applica-
tions
DC CONTROL
VIDEO CONTROL
• No automatic compen-
sation for light changes
• Iris operation con-
trolled by DC motor
voltages from the
camera
• Iris operation con-
trolled by video to
voltage motor con-
trol signals from the
camera
• Indoor use
• Minimal light variations
• Level control ONTHE
• Level control ON
THE LENS
CAMERA
• Only choice available
if you wish to use the
auto-iris feature with
B/W cameras
12
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
Lens/Camera Setup and Backfocusing
Information Box
Information Box
The purpose of backfocusing is to make the adjustments necessary for the picture to remain in focus throughout the camera‘s zoom
range, which is the case for instance, in motorized zoom, auto-iris configurations.Manual iris lens/camera combinations also need to be
backfocused. Follow the general instructions listed below to adjust back focus appropriate to your camera/lens combination.
LENS TYPE
NOTE: We are essentially referencing indoor lighting condi-
tions in each of the cases below. If you have occasion to use
fixed lenses in an outdoor setting, where lighting is much brighter
(not widely done with fixed lenses), you may need to filter the
light while performing these adjustments.
AUTO IRIS
A
B
MANUAL IRIS
STATIC LIGHT CONDITIONS
VARIABLE LIGHT CONDITIONS
Generic Lens with Manual
Iris and Focus
• Adjust back focus the
same as was done for vari-
able light conditions except
CCD Iris is left in the OFF
position; therefore there is
no need to adjust the Iris
Level control; follow all
other steps, however.
• Turn manual iris
ring so iris is fully
open and set the fo-
cus ring for
(or
∞
distant object).
Manual
Focus
Manual
Iris
• Set all other switch-
es on the back of the
camera to the left
(deactivated or OFF),
including the CCD
Iris switch.
AGC
TURBO
AGC
CCD IRIS*
* With CCD Iris
OFF, the Iris Level
control is inactive
• Adjust the C/CS ad-
justment ring for
the best picture.
Generic example of best
setting for C-mount lens.
Best setting
Adjustment
Ring
Picture will be out
of focus on either
side of best setting
• Move CCD Iris switch
to the ON position.
AGC
TURBO AGC
BLC
CCD IRIS (ON)
• Set the Iris Level con-
trol pot to the Hposition.
IRIS LEVEL
• Adjust or set other cam-
era switches as needed.
L
H
Pelco Manual C1900M (4/99)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Backfocusing
Lens/Camera Setup and Backfocusing
Information Box
Information Box
The purpose of backfocusing is to make the adjustments necessary for the picture to remain in focus throughout the camera‘s zoom
range, which is the case, for instance, in motorized zoom, auto iris configurations. Manual iris lens/camera combinations also need to
be back focused. Follow the general instructions listed below to adjust back focus appropriate to your camera/lens combination.
LENS TYPE
NOTE:Most auto-iris configurations are associated with motorized zoom
B
lenses, so the instructions below are based on that assumption.
MANUAL IRIS
AUTO IRIS
A
VIDEO SERVO
DC SERVO
• Make sure the Auto IrisVideo/
DC switch is in the DC posi-
tion. Use a neutral density
filter or some other physical
means to decrease the
amount of light entering the
camera lens so that the auto-
iris response is to open the
iris up as wide as possible.
• This step is the same as the
one for DC SERVO, except
that the AUTO IRIS VIDEO/
DC switch is set to VIDEO.
AUTO IRIS
VIDEO DC
AUTO IRIS
VIDEO DC
• Set all other switches on the
back of the camera to the left
(deactivated or OFF), includ-
ing the CCD Iris switch.
• This step is the same as for
DC servo.
AGC
TURBO AGC
BLC
CCD IRIS*
* With CCD Iris OFF,
the Iris Level control is
inactive.
BACKFOCUS ADJUSTMENT
Generic example of best
setting for C-mount lens
• Adjust focus to far, zoom to
wide angle.
• Adjust C/CS adjustment
ring on the camera for the
best picture.
• This step is the same as for
DC servo.
Best setting
Adjustment
Ring
• Zoom to a close object; ad-
just lens controller or focus
for best picture.
• Repeat above until lens re-
mains in focus throughout
the zoom range (far to near).
• Tighten the lock screw.
Picture will be out
of focus on either
side of best setting.
The ability of a zoom lens to remain in focus throughout its zoom range is known as tracking.
• Finally, use the IRIS LEVEL
adjustment to adjust for best
picture.
IRIS LEVEL
• For AUTO-IRIS applications
using VIDEO servo, set the
IRIS LEVEL control pot to
the H position.
• Adjust other settings on cam-
era as needed.
L
H
14
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
1
E
3
2
4
LOCK
Fitting the Lens
5.0 CAMERA INSTALLATION
CAUTION: CABLE ROUT-
ING. Be sure cable wires are
routed so as to not pinch or rub
when connected to pan/tilt units.
Frayed, pinched or broken wires
can cause fire/shock hazards or
system failure.
ATTENTION: Installation should be per-
formed by qualified service personnel only in
accordance with the National Electrical Code
or equivalent/applicable local codes.
5.1 CONNECTING THE CC3300-2/
CC3300-2X (Illustration F )
NOTES: When using a transformer without
a ground lead (two-lead type), connect the out-
put of the transformer to the 24 VAC terminals
(1 and 2) of the camera.
1. Connect the power lines to the camera.
CC3300-2: 24 VAC, 60 Hz
CC3300-2X: 24 VAC, 50 Hz
2. Connect the 75-ohm coaxial cable to the video
When using a transformer with a ground lead
(three-lead type), connect the ground lead to
the GND terminal and the other two leads to
the 24 VAC terminals (1 and 2).
monitor.
3. Connect the wall outlet transformer.
To prevent a short circuit, do not let the ex-
posed transformer leads brush against conduc-
tive material when connecting to the 24 VAC
terminals.
Pelco Manual C1900M (4/99)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
F
CC3300-2/
CC3300-2X
2
1
3
Connecting the CC3300-2/CC3300-2X
G
CC3300-3
1
2
Connecting the CC3300-3
16
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
6.0 OPERATION
5.2 CONNECTING THE CC3300-3
(Illustration G )
The following are characteristics that may be observed
when viewing an image produced by a CCD camera.
These are inherent characteristics of the CCD camera
and do not stem from any fault within the camera it-
self.
1. Connect the 75-ohm coaxial cable to the video
monitor.
2. Connect the main leads/power cord (220-240 VAC,
50 Hz only).
Vertical smear - This phenomenon occurs when
viewing a very bright object.
5.3 VERTICAL PHASE (See Figure 6)
Patterned noise - This is a fixed pattern which
may appear over the entire monitor screen when the
camera is operated at a high temperature.
Vertical phase adjustment is not vertical roll adjustment.
Each camera is adjusted to theAC zero crossover point
at the factory. Problems arise, however, (especially in
larger systems) when:
Jagged picture- When viewing stripes, straight lines
or similar patterns, the image on the screen may appear
jagged.
1. Switching rapidly between widely separated cam-
eras with manual or sequential switchers.
Avoid operating or storing the unit in the following lo-
cations:
2. Switching between cameras not operating off the
same phase of the AC line.
•
Extremely hot or cold places (operating tempera-
ture – 14° to 122°F [-10° to 50°C])
3. Both of the above. There are other causes too (trans-
formers wired backward, for instance) but the basic
symptoms described below require V-phase adjust-
ment.
•
•
•
•
Damp or dusty places
Exposed to rain
In such cases, camera switching may produce what ap-
pears to be a vertical roll on the monitor between the
two views. Turning the V Phase pot (while switching
rapidly as possible between the two camera views) will
adjust the relative phase angle between the two cam-
eras and the point at which one camera synchronizes to
the AC line with respect to the other. Adjust the pot
until the switching is clean and there is no vertical roll
or flip.
Exposed to strong vibration
Close to generators of strong electromagnetic ra-
diation such as radio or TV transmitters
•
Exposed to fluorescent light reflections or unstable
(flickering) lighting conditions
CAUTION: The camera
should not be pointed at the sun,
or used for shooting very bright
objects, as the CCD imager may
be permanently damaged.
Figure 6. Vertical Phase
Pelco Manual C1900M (4/99)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
7.0 MAINTENANCE
8.0 SPECIFICATIONS
•
Remove dust or dirt on the surface of the lens or
CCD with a blower.
Image Device: 1/3-inch Interline transfer type CCD
Sensing Area:
1/3-inch format (3.3 x 4.4 mm)
•
Use a soft, dry cloth to clean the body. If it is very
dirty, use a cloth dampened with a small quantity
of a neutral detergent, then wipe dry.
Effective Picture
Elements:
CC3300-2:
510 H x 492 V
•
Avoid using volatile solvents such as thinner, al-
cohol, benzene, and insecticides. They may dam-
age the surface finish and/or otherwise impair the
operation of the camera.
CC3300-2X: 500 H x 582 V
CC3300-3:
500 H x 582 V
Horizontal
Resolution:
330 TV lines
Minimum
Illumination:
1.0 lux at f/1.2 (Turbo AGC on)
1/60 to 1/100,000 second
CCD Iris:
CC3300-2:
CC3300-2X: 1/50 to 1/100,000 second
CC3300-3: 1/50 to 1/100,000 second
CCD Iris Control: ON/OFF switchable
Lens Type:
VIDEO/DC servo switchable
Power Requirements:
CC3300-2:
24 VAC, 60 Hz
CC3300-2X: 24 VAC, 50 Hz
CC3300-3:
220-240 VAC, 50 Hz
Power Consumption:
CC3300-2:
3.5 W
CC3300-2X: 3.5 W
CC3300-3:
4 W
Sync System:
CC3300-2:
AC line lock 60 Hz
CC3300-2X: AC line lock 50 Hz
CC3300-3:
AC line lock 50 Hz
AGC:
ON/OFF/Turbo switchable
Signal System:
CC3300-2:
NTSC color system
CC3300-2X: PAL color system
CC3300-3: PAL color system
White Balance: ATW only
Video Signal:
1.0voltpeaktopeakat75ohms,sync
negative
18
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
S/N Ratio:
46 dB (AGC off)
Phase Control: V-phase adjustment (±90°)
Lens Mount:
Dimensions:
C/CS mount (adjustable)
5.50 in. L x 2.75 in. W x 2.56 in. H
(13.97 x 6.99 x 6.51 cm)
Mounting Plate
Height:
0.25 inches (6.15 mm)
Weight:
CC3300-2:
CC300-2X:
CC3300-3:
1.1 lb (.50 kg)
1.1 lb (.50 kg)
1.4 lb (.64 kg)
Construction:
Finish:
Steel case
Neutral gray
Operating
Temperature:
14° to 122°F (-10° to 50°C)
Storage
Temperature:
-40°F to 140°F (-40° to 60°C)
Relative Operating
Humidity:
20 to 80% (non condensing)
20 to 95%
Relative Storage
Humidity:
Shock
Resistance:
70 G
4-pin
Auto-Iris Lens
Connector:
(Design and product specifications subject to change
without notice.)
Pelco Manual C1900M (4/99)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
Exceptions to this warranty are as noted below:
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual #
C1900M
Date
11/96
4/99
Comments
Original version.
Added model CC3300-2X.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
©Copyright 1999, Pelco.
All rights reserved.
20
Pelco Manual C1900M (4/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
|