®
CC5BCBW Series
Heavy-Duty Spectra®
Back Box
Installation Manual
C2434M (7/01)
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
DESCRIPTION
The Heavy-Duty Spectra is perfect for installations where structural integrity and vandalism
are a priority. The system features heavy-duty construction and tamper-resistant barrel key
locks. The in-ceiling model has a reinforced bracket mounting system for installation in a
fixed ceiling. Pendant models can be mounted to a pole, corner or directly to a wall.
SYSTEM MODELS
CC5BCBW-HF1
Heavy-duty, in-ceiling back box; standard clear dome; and color/black
and white camera.
CC5BCBW-HBF1 Heavy-duty, in-ceiling back box; heavy-duty clear dome; and color/
black and white camera.
CC5BCBW-HP1
Pendant style back box, standard clear dome, and color/black and
white camera.
CC5BCBW-HBP1 Pendant style back box, heavy-duty clear dome, and color/black and
white camera.
Each heavy-duty lower dome is designed for a specific back box model. Install the correct
lower dome to the right back box. See the following chart.
System Model
CC5BCBW-HF1
CC5BCBW-HBF1
CC5BCBW-HP1
CC5BCBW-HBP1
Back Box
Lower Dome
Dome Drive
DD5BCBW
DD5BCBW
DD5BCBW
DD5BCBW
BB5HD-F
CLCLD5HDF-1
CLCLD5HDBF-1
CLCLD5HDPG-1
LD5HDPG-1
BB5HD-F
CLCBB5HD-PG
CLCBB5HD-PG
Pelco Manual C2434M (7/01)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION OF IN-CEILING MODEL
STEP 1 - PREPARE CEILING
00530
00532
00531
a. Locate the center point of the mount-
ing location. Drill a hole in the ceiling
using a 3/32-inch drill.
b. Insert the compass tool into the hole.
c. Use the mounting ring as a template
and mark the hole pattern onto the
mounting surface. Prepare the holes.
Draw a circle on the ceiling using the
compass tool and a pencil. Cut the
circle out of the ceiling.
STEP 2 - INSTALL THE MOUNTING PLATES
S
Use the eight 10-32 x 3-inch screws (supplied) and install the mounting ring and
two back mounting plates.
CEILING
a. Line up the mounting ring with the eight
fastener holes.
c. Install fasteners through the mounting
ring, ceiling and out the back mounting
plate.
b. Feed one back mounting plate through
the hole in the ceiling and line up with
four fastener holes.
MOUNTING
RING
d. Install second back mounting plate.
00533
STEP 3 - INSTALL THE BACK BOX
SPRING CLIP
ATTACH SAFETY CHAIN HERE
8-32X.275 INCH SCREW
00534
00535
00537
a. Attach the conduit fitting, lock nut, and
safety chain bracket. Install a safety
chain/cable (not supplied) that will
support up to 16 pounds (7.3 kg).
b. Turn the thumbscrew and open the
hinged door to the back box.Pull wiring
into the back box through the conduit
fitting. Refer to Tables A and B in the
Appendix for wiring distances.
c. Compress the spring clips on the back
box and push it through the hole until
the clips spring back.Tighten the screws
until you hear a clicking noise. Insert the
two 8-32 x .275-inch screws to secure
the back box to the mounting ring.
4
Pelco Manual C2434M (7/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 4 - WIRE CIRCUIT BOARD
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
Attach the wiring to the circuit board inside the back box. When
finished, close the door to the back box and turn on the power.
The red LED will light.
CONTROLLER
VIDEO IN
COAXITRON
CONTROLLER
VIDEO OUT
IMPORTANT: If the LED does not light, refer to the Trouble-
shooting section.
2 WIRE
CONTROLLER
TX-
TX+
RX-
RX+ CONTROL
TX-
NOT USED
NOT USED
(RS-422)
TX+
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
1
2
3
4
5
6
7
Aux 2 - Maximum 150 vA at 32 VDC
ALARM
INPUTS
SPECTRA II ONLY
GROUND
(NO)
(NC)
SWITCHES
(WIRING EXAMPLE)
+5 VDC
+5 to +24 VDC
RELAY
(AUX 1)
LOGIC GATE
(WIRING EXAMPLE)
AUX 2
GROUND
HEATER/FAN (NOT USED)
AUX 2
EXTERNAL RELAY
(WIRING EXAMPLE)
00542
STEP 5 - INSTALL DOME DRIVE
SW1
ON
SW2
RED
1
ON
1
2
2
3
3
4
4
6
6
5
5
7
7
8
8
TAB
GREEN
TAB
LABEL
SW1
SW2
LAB
EL
SW2
RS-422 TERMINATION SWITCH
00539
00538
a. Set the DIP switches for SW1 and SW2 on the bottom of the
dome drive for the appropriate receiver address. Refer to the
labels on the dome drive orTables C through E in the Appendix
in the back of this manual.
b. Line up the green and red tabs with the green and red labels.
Push in on the tabs. Insert the side with the green tab, then the
side with red tab. Continue pushing on the ends of the tabs
until both sides click into place.
STEP 6 - INSTALL LOWER DOME
a. Attach the lower dome trim leash to one of the 8-32 x .275-
inch screws that secure the back box to the mounting ring.
b. Insert both keys in the barrel locks. Turn keys clockwise to the
unlocked position. Keys can not be removed from lock in the
unlocked position.
BALL STUD
BALL STUD
RECEIVER
c. Align pegs (located on the mount ring) with the peg recep-
tacles (located on the inside of the lower dome).
TRIM LEASH
d. Place lower dome over back box. Hold and turn both keys to
the locked position.
TO USE YOUR DOME, REFER TO THE OPERATION AND
PROGRAMMING MANUAL.
BARREL
KEY LOCK
00497
Pelco Manual C2434M (7/01)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION OF PENDANT MODELS
STEP 1 - DISASSEMBLE BACK BOX
01082
01081
a. Turn the thumbscrew and open the hinged door located
inside the back box.
b.
Unscrew the three Phillips screws located underneath the
hinged door. Remove the inside portion of the back box.
01080
c.
Remove the inside mounting plate by loosening the three
Phillips screws.
STEP 2 - PREPARE INSTALLATION AREA
NOTE: If installing outdoors make sure the installation is properly sealed to keep moisture out.
Prepare cable and wiring for the system. Refer to Tables A and B in the Appendix for wiring distances.
There are three different methods of installation:
1. Direct Mounting to a Wall – Use the mounting side of the octagonal back box as a template and mark the three fastener holes
and conduit hole onto the mounting surface. Set the back box to the side and prepare the holes for the installation.
2. Corner Mounting – Refer to the instructions supplied with the CLCCM corner mount.
3. Pole Mounting – Refer to the instructions supplied with the CLCPA pole adapter.
6
Pelco Manual C2434M (7/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 3 - INSTALL THE BACK BOX
01078
01079
a. Secure the conduit fitting to the hole located on the inside
base of the octagonal back box.
c.
Thread the cable/wiring through the back box mounting
plate. Attach the plate to the mounting base using the
screws previously removed. Pull cable/wiring into the
inside back box (the back box hinged door should be
opened). Attach the inside back box to the mounting plate.
Use the three Phillips head screws previously removed.
b. Pull the cable and wiring for the system through the
octagonal back box and conduit fitting. Mount the back
box to the mounting surface, corner, or pole mount.
STEP 4 - WIRE CIRCUIT BOARD
Attach the wiring to the interconnect circuit board inside
the back box. Close the door to the back box. Turn on
power to the back box. The red LED will light.
24 VAC
TRANFORMER
POWER
(24 VAC ONLY)
CONTROLLER
VIDEO IN
COAXITRON
CONTROLLER
VIDEO OUT
IMPORTANT: If the LED does not light, refer to the
Troubleshooting section.
2 WIRE
CONTROLLER
TX-
TX+
RX-
RX+ CONTROL
NOT USED
NOT USED
(RS-422)
TX-
TX+
NOTE: Aux 1 - Maximum 2A at low voltage (<40V)
Aux 2 - Maximum 150 vA at 32 VDC
1
2
3
4
5
6
7
ALARM
INPUTS
SPECTRA II ONLY
GROUND
(NO)
(NC)
SWITCHES
(WIRING EXAMPLE)
+5 VDC
+5 to +24 VDC
RELAY
(AUX 1)
LOGIC GATE
(WIRING EXAMPLE)
AUX 2
GROUND
HEATER/FAN (NOT USED)
AUX 2
EXTERNAL RELAY
(WIRING EXAMPLE)
00542
Pelco Manual C2434M (7/01)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 5 - INSTALL DOME DRIVE
SW1
ON
SW2
1
ON
1
2
2
3
3
4
4
6
6
5
5
7
7
8
8
LABEL
SW1
SW2
LAB
EL
SW2
RS-422 TERMINATION SWITCH
00538
a. Set the DIP switches for SW1 and SW2 on the bottom of
the dome drive for the appropriate receiver address. Refer
to the labels on the dome drive or Tables C through E in
the Appendix in the back of this manual.
01083
b. Daisy Chain Operation Only – When connecting more
than one Spectra dome system to a single controller,
terminate the last unit in the chain (farthest from the
controller). To terminate the dome drive set the RS-422
termination switch to the left.
c.
Line up the green and red tabs with the green and red
labels. Push in on the tabs. Insert the side with the green
tab, and then the side with red tab. Continue pushing on
the ends of the tabs until both sides click into place.
STEP 6 - INSTALL LOWER DOME
BARREL
LOCK
TRIM
LEASH
O-RING
00543
01084
a. Lightly apply O-ring lubricant to the O-ring. Install the
O-ring in the groove on the trim ring of the lower dome.
Attach the back box trim leash to a retainer screw inside
the lower dome.
b.
Align barrel locks in lower dome with the holes located on
each side of the back box. Push lower dome onto back
box. Press the pins of the barrel locks IN to secure the
lower dome.
Environmental Model only – Plug the two-pin heater connection
in the lower dome into the mating connector in the back box.
TO USE YOUR DOME, REFER TO THE OPERATION AND
PROGRAMMING MANUAL.
8
Pelco Manual C2434M (7/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Unit does not operate.
The controller is not
communicating with
the Spectra unit.
Check to see if the red LED on the circuit
board in the back box is lit.
1. The red LED is not lit.
a. Fuse is bad.
a. Check fuse on the circuit board. Replace fuse if it is
bad. To order a fuse from Pelco, specify the part
number FUS1.6-5X20FAST. This is a 1.6-ampere
fuse, 5 x 20 mm, fast blow.
b. 24 VAC power source is not con-
nected or back box is bad.
b. Use a voltmeter to check if 24 VAC is getting to the
power connector on the circuit board. If NO, check
your power supply. If YES, return the back box to
the factory for repair.
2. The red LED is lit.
a. Wiring is incorrect or is not fully
seated.
a. Check all connections to the circuit board.
Make sure that all connections are fully seated and
the board is wired correctly.
b. DIP switch settings are incorrect.
b. Check the DIP switch settings on the dome drive
(refer to Tables C, D, and E). If the unit still does
not operate, turn off power and replace the dome
drive with a good unit, if you have a spare. Check
the switch settings on the substitute dome drive
before installing it. (If you do not have a spare,
return the dome drive and back box to the factory.)
If you substituted a dome drive and the unit
operates, the original dome drive is bad (return
the dome drive to the factory). If the unit still
does not operate, then the circuit board is bad
(return the back box to the factory).
Fan does not
operate.
Fan connections are not fully seated.
Cameras are out of phase.
Make sure the connector for the fan is fully seated. If
the fan still does not operate, return the back box and
dome drive to the factory for repair.
Vertical roll on monitor
when switching
between cameras.
If you are wiring more than one dome to the same
transformer, it is important to wire the power connec-
tor in each dome the same way. That is, the wiring
from one side of the transformer must be connected
to the same connector on each dome.
DOME 1
POWER
WARNING: Make
sure you wire power
to the outer connec-
tors of the terminal
block and ground to
the middle connec-
tor. Otherwise, you
DOME 2
POWER
could damage the
DOME 3
POWER
Pelco Manual C2434M (7/01)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
Table A. Video Coaxial Cable Requirements
Cable Type*
Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance. All-copper center conductor.
95% braided copper shield.
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a 10-
percent voltage drop. (Ten percent is generally the maximum allowable voltage
drop for AC-powered devices.)
Wire Gauge
20
18
16
14
12
10
30 vA
75 vA
94 ft
(28 m)
150 ft
(45 m
238 ft
(115 m)
380 ft
(72 m)
603 ft
(183 m)
960 ft
(292 m)
37 ft
60 ft
95 ft
152 ft
241 ft
384 ft
(11 m)
(18 m)
(29 m)
(46 m)
(73 m)
(117 m)
NOTE: Input power for the dome is 24 VAC only. Power consumption is 30 vA
per dome for indoor models and 75 vA for outdoor models.
Use a 24 VAC transformer with the following minimum vA:
40 vA per dome
100 vA per dome
For indoor models (without heater)
For outdoor models (with heater)
Table C. Switch Settings for SW1
Control Type
Switch Setting
SW1-1
OFF
SW1-2
OFF
SW1-3
SW1-4
OFF
SW1-5
OFF
SW1-6
OFF
SW1-7
OFF
SW1-8
OFF**
OFF**
OFF**
Coaxitron®
OFF
OFF
OFF
P-Type Control
D-Type Control
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF*
NOTES: Switches SW 1-3 through SW 1-6 MUST be OFF.
D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500, CM8500, and Genex® controllers or with
American Dynamics control systems using the AD2083 Translator.
P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 and Genex control systems.
OFF- Use with controllers that have more than 32 presets.
*
ON- Use with American Dynamics controllers (32 presets).
** OFF - Use with all control systems except CM9502 with variable speed keyboards.
For CM9502 with fixed speed keyboards, set switch OFF.
ON - Use with CM9502 with variable speed keyboards for smoother joystick control.
10
Pelco Manual C2434M (7/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table D. Switch Settings for SW2 – P-Type Control
NOTE: For Coaxitron controls, SW2 is not used; set all switches OFF. For D-type control systems, refer to Table E.
Receiver
Address
Switch Setting
SW2-3
Receiver
Address
Switch Setting
SW2-3
SW2-1
SW2-2
SW2-4
SW2-5
SW2-1
SW2-2
SW2-4
SW2-5
1
2
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
3
OFF
ON
OFF
ON
4
ON
ON
5
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
6
ON
ON
7
OFF
ON
ON
OFF
ON
ON
8
ON
ON
ON
ON
9
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
10
11
12
13
14
15
16
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
Baud Rate
Switch Setting
SW2-6
SW2-7
SW2-8
2400
4800
9600
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
Table E. Switch Settings for SW2 – D-Type Control
NOTE: For Coaxitron controls, SW2 is not used; set all switches OFF. For P-type control systems, refer to Table D.
Receiver
Address
Switch Setting
Receiver
Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
1
2
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
3
ON
ON
ON
ON
4
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
5
ON
ON
ON
ON
6
OFF
ON
ON
OFF
ON
ON
ON
ON
7
ON
ON
ON
ON
ON
ON
8
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
9
ON
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
(Continued on next page)
Pelco Manual C2434M (7/01)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver
Address
Switch Setting
Receiver
Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
(Continued on next page)
12
Pelco Manual C2434M (7/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver
Address
Switch Setting
Receiver
Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
Pelco Manual C2434M (7/01)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
MECHANICAL
Construction
Back box:
Dome drive:
Lower dome:
Cable Entry
In-Ceiling:
Pendant:
Pan Movement:
Vertical Tilt:
Manual Pan/Tilt Speeds*
Pan:
Aluminum
Aluminum, ABS plastic
Acrylic
.75-inch (1.91 cm) conduit fitting
Through 1.5-inch (3.81 cm) NPT pendant mount
360° continuous pan rotation
Unobstructed +2° to -92°
0.1-80° /sec manual operation, 150° /sec turbo
Tilt:
0.1-40° /sec
Preset Speeds
Pan:
250° /sec
Tilt:
200° /sec
* For variable-speed operation an appropriate controller is required. With fixed-speed
controllers, pan/tilt speed is 24°/sec. The CM6700 controller with the KBD200 keyboard
has programmable fixed speeds.
ELECTRICAL
Input Voltage:
Input Power:
18-30 VAC, 24 VAC nominal
30 vA nominal (indoor, w/o heater)
75 vA nominal (outdoor, with heater)
1.6 A
Fuse:
Relay Contacts
Type:
Voltage:
Current:
AUX 1
Form C
Low voltage (<40 V)
2 A maximum
AUX 2 Output
Open collector transistor output
32 VDC maximum
150 mA maximum
CAMERA
Signal Format:
Scanning System:
Image Sensor:
Effective Pixels:
Horizontal Resolution:
Lens Minimum f-stop:
Focal Length:
NTSC (model DD5BCBW)
2:1 interlace
1/4-inch interline transfer CCD
768 (H) x 494 (V)
>470 TV lines
F1.4
4.1 mm to 73.8 mm optical
18X optical zoom, 4X electronic zoom
Auto/manual speed selection
Zoom Ratio:
Digital Slow Shutter:
Horizontal Angle of View: 48° (at 4.1 mm wide zoom), 2.7° (at 73.8 mm telephoto zoom)
MTBF:
Focus:
>500,000 cycles at room temperature (zoom, focus, irs)
Automatic and manual override
Sensitivity: .
2 lux at 1/4-second shutter speed (color)
.2 lux at 1/60-second shutter speed (black & white)
AC line lock, phase adjustable via remote control*
Automatic with manual override*
Speed Automatic (electronic iris)/manual
1/4 to 1/10,000*
Sync System:
White Balance:
Shutter:
Iris Control:
Gain Control:
Video Output:
Signal to Noise Ratio:
Automatic with manual override*
Automatic with manual override*
714V ± .07V (100 IRE ± 10 IRE)
>46 dB
* Manual control of camera setup functions can be done with CM6700, CM6800, CM8500,
CM9500, CM9740, CM9760 and MPT9500 controllers, but not with CM7500, MPT9000
or KBD9000 controllers.
14
Pelco Manual C2434M (7/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL
Environment
In-Ceiling:
Indoor only
Pendant:
Indoor/outdoor
Operating Range
In-Ceiling:
32 to 122°F (0 to 50°C)
Pendant:
(Assumes no wind chill factor; for detailed test conditions,
contact Pelco)
Maximum:
140°F (60°C) absolute maximum
122°F (50°C) sustained maximum
-15°F (-9.4°C) absolute minimum
See Figure 1
Minimum
Dimensions:
Weight Unit
Back Box and Lower Dome
In-ceiling:
3 lb (1.36kg)
Pendant:
Dome Drive:
7 lb (3.17 kg)
2.65 lb (1.20 kg)
(Design and product specifications subject to change without notice.)
10.25
(26.03)
10.37
(33.95)
6.8
(17.27)
fl6.13
(fl15.57)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES
Figure 1. Dimension Diagram
Pelco Manual C2434M (7/01)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
1. Model and serial number
Exceptions to this warranty are as noted below:
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual #
Date
Comments
C2434M
7/01
Original version.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
© Copyright 2001, Pelco.
All rights reserved.
16
Pelco Manual C2434M (7/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
|