Pelco Refrigerator MT10P User Manual

HT10V/MT10PKIT O-Ring Replacement Kit For  
HT10V Series High Temperature And  
MT10P Medium Temperature  
Liquid-Cooled Enclosures  
®
Installation Instructions  
C1955M (11/98)  
O-RING REPLACEMENT (HT10V Series Enclosures)  
1.0 INSTALLATION  
1. Turn off power to the enclosure.  
2. Disconnect the in and out hoses for fluid from the fittings on the front plate of the  
enclosure and allow the fluid to completely drain from the front plate.  
3. Remove the V-groove hose clamp that attaches the enclosure front plate to the  
enclosure.  
4. Remove the desiccant bags inside the enclosure and replace them with the two  
bags from the kit.  
5. Remove the eight screws and lock washers from the enclosure front plate that attach  
the backup plate, window, O-ring retainer, and O-ring.  
6. Remove the O-ring and discard.  
7. Place the enclosure front plate on a flat surface with the inside surface facing upward.  
8. Position the new O-ring in the groove on the enclosure front plate around the window  
opening.  
9. Position the O-ring retainer on top of the O-ring, then position the window and the  
backup plate on top of the window. Align the screw holes in the backup plate with  
the holes in the enclosure front plate.  
10. Reinstall the screws and lock washers finger tight, then tighten them in a star pattern.  
Ensure new O-ring remains in the correct position.  
11. Place the enclosure front plate on the enclosure and reinstall theV-groove hose clamp.  
12. Reconnect the in and out hoses for fluid to the fittings on the front plate of the  
enclosure.  
O-RING REPLACEMENT (MT10P Enclosure)  
1. Turn off power to the enclosure.  
2. Remove the V-groove hose clamp that attaches the enclosure front plate to the  
enclosure.  
3. Remove the desiccant bags inside the enclosure and replace them with the two  
bags from the kit.  
4. Remove the eight screws and lock washers from the enclosure front plate that attach  
the backup plate, window, and O-ring.  
5. Remove the O-ring and discard.  
CAUTION:  
T h e r e  
6. Place the enclosure front plate on a flat surface with the inside surface facing upward.  
7. Position the new O-ring on the enclosure front plate around the window opening.  
is no groove for the O-ring  
on this model enclosure.  
Make sure the new O-ring  
remains in the correct po-  
sition when reassembling  
the window and backup  
plate onto the enclosure  
front plate.Over-tightening  
the screws may cause the  
O-ring to displace.  
8. Position the window on top of the O-ring, then position the backup plate on top of  
the window. Align the screw holes in the backup plate with the holes in the enclosure  
front plate.  
9. Reinstall the screws and lock washers finger tight, then tighten them in a star pattern  
until they are snug. Do not over-tighten. Ensure new O-ring remains in the correct  
position.  
10. Place the enclosure front plate on the enclosure and reinstall theV-groove hose clamp.  
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150  
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pelco Home Security System C3407M D User Manual
Pentair Swimming Pool Pump SuperFlo User Manual
Philips Car Amplifier TDA8566 User Manual
Philips Car Video System 200VW8 User Manual
Philips Cell Phone CT2898 User Manual
Philips CRT Television 15PT1320 User Manual
Philips Portable DVD Player PD703 User Manual
Pioneer Car Stereo System NDBC20PA User Manual
PMC Sierra Network Card PM5347 User Manual
Porter Cable Saw 36 225 User Manual