Pelco Marine Lighting L560 User Manual

User Instruction & Installation Manual  
L560 Remote Control 2/3Kw  
Tungsten Halogen Searchlight  
Product Reference Number:  
A2651 – Variable Speed Motor Unit 2/3Kw 115/240v  
Manufacturers details:  
Distributor details:  
Francis Searchlights Ltd  
Union Road, Bolton  
Lancashire, BL2 2HJ, UK  
Tel:  
Fax:  
+44 (0) 1204 558960  
+44 (0) 1204 558979  
Manual Part Number: C21514  
Issue : 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 - Introduction  
It is imperative that this manual is read carefully and understood before  
installing your equipment. For your future reference please keep this manual in  
a safe place.  
Thank you for specifying a product from the Francis Searchlights range. All Francis products are  
designed to give complete customer satisfaction and are manufactured to the highest engineering  
standards in order to ensure optimum performance and service life.  
The Francis Lite range combines features proven over many years service in the most hazardous  
conditions in both marine and land installations.  
In order to prolong the life and performance of your product, we recommend that you only specify  
Francis Searchlights spare parts. This will also ensure that any warranties on your equipment will  
not be invalidated. Information on spares ordering and parts is provided in this manual.  
Should you ever need to contact Francis Searchlights Ltd. regarding your equipment, please quote  
the Product Serial Number at all times.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2 - Safety Precautions  
The following instructions must be adhered to, in order to ensure a safe working environment and  
the safety of the user.  
Note: When unpacking or manoeuvring the searchlight into its fixing position, suitable  
lifting points must be used in order to prevent damage to the equipment or personal injury.  
Prevent rain, snow, condensation and water droplets from contacting the lamp as this may  
cause bulb failure and possible shattering;  
Quartz halogen bulbs run with a high internal pressure in excess of atmospheric. Whilst the  
construction is inherently strong, there is a slight risk of the bulb shattering;  
Never look directly into an illuminated searchlight as this may cause severe damage to  
eyesight. If it is necessary to inspect a lamp whilst in operation, always wear suitable protective  
goggles;  
Should it be necessary to examine the lamp with the front bezel removed, always use a  
protective shield and wear goggles to ensure a safe working environment;  
Never attempt to clean a lamp whilst in use;  
Searchlights get hot. Never touch the unit when lit and always allow 15 to 20 minutes for  
cooling down after turning the searchlight off;  
Never place anything on or cover the searchlight when in use;  
Ensure the lamp has cooled sufficiently before removal;  
If undue force appears necessary to remove the lamp, the equipment should be inspected by a  
competent person or contact the manufacturer;  
When breaking a lamp for disposal, care must be taken to ensure the glass fragments are  
safely contained. This operation must be performed out of doors in free air. In all  
circumstances refer to the lamp manufacturers instructions packed with the lamp;  
Due to the vast range of lamps available it may appear possible that more powerful lamps can  
be used in the equipment than for which it was designed. Even when the unit will physically  
accept a higher wattage or voltage lamp, this substitution is not recommended and is  
dangerous. This action will also void any warranties on the equipment.  
Always refer to the lamp manufacturers technical data when dealing with lamps.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3 - Technical Information  
This product has been designed to operate in accordance with the product specification. The  
L560RC searchlight has the following features:  
All marine grade materials and fixings;  
Parabolic formed aluminium reflector;  
Powder coated / Stove enamel paint finish;  
385° horizontal rotation;  
Vertical movement ±20°;  
Motor speed 20°/sec fast, 10°/sec slow (Pan)  
0-10°/sec fast, 0-5°/sec slow (Tilt);  
Effective weather sealing to IP66;  
Toughened front glass;  
The searchlight also performs to the following optical data:  
2000 Watt T/H  
3000 Watt T/H  
Supply voltage  
Peak Beam Candlepower  
Range  
220/240v or 110/115v  
2,7495,697 lux  
1657 metres  
220/240v or 110/115v  
3,127,043 lux  
1768 metres  
6.4°  
Divergence  
4.8°  
Temperature range  
-20°C to +50°C  
-20°C to +50°C  
In order that the searchlight operates correctly it is imperative that competent personnel are  
responsible for the installation, operation and servicing of this equipment. Failure to adhere to this  
advice may cause premature failure or incorrect operation of the searchlight, which may damage  
the equipment or cause personal injury.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4 - Unpacking and Installation Instructions  
The following instructions should be read and fully understood prior to installing the equipment to  
ensure that the correct procedures are followed and all safety precautions are observed.  
Note: If the equipment has been in storage for a considerable amount of time, it is advisable  
to conduct a routine maintenance check on all parts before installation.  
Safety Precautions  
This equipment should not be connected to an electrical supply before being installed. Installation  
procedures should be adhered to in order to ensure a safe working environment and reduce the  
risk of damage or personal injury.  
Preparing the Mounting Position  
Mark out and drill the fixing holes through the deck. If anti-vibration mounts are to be fitted, the  
fixing holes for the mounts should also be marked out and drilled. Prior to manoeuvring the  
searchlight into its’ fixing position, the AV mounts should be fitted to the base. When in the desired  
position, and bolt the searchlight firmly down. On an uneven surface it may be necessary to use a  
suitable sealant such as silicone, in order to ensure a weatherproofed joint.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 - Electrical Installation  
For safety purposes, only competent personnel should perform the electrical installation. All  
equipment should be installed to current Electrical Regulations and Standards.  
In order to obtain the maximum light output from the searchlight, it is essential that the full  
operating voltage of the lamp fitted be applied to the lampholder contacts.  
Method of Electrical Connection  
1) Disconnect the supply before working on the electrical system;  
2) The searchlight must be connected to a fused electrical supply, using suitably sized cable;  
3) If the searchlight is located a considerable distance from the supply, provision must be made in  
the cable size in order to overcome the voltage drop.  
The following table below indicates the maximum length of cable to be used for the AC supply  
cable, from the control panel to the searchlight:  
Searchlight  
120v 2Kw  
230v 2Kw  
240v 2Kw  
115v 3Kw  
230v 3Kw  
Cable Size (mm²) Distance Max Distance Max Distance Max Distance Max Distance Max  
2.5  
4
6
15 MTRS  
24 MTRS  
37 MTRS  
62 MTRS  
55 MTRS  
88 MTRS  
137 MTRS  
230 MTRS  
60 MTRS  
96 MTRS  
150 MTRS  
251 MTRS  
9 MTRS  
14 MTRS  
22 MTRS  
38 MTRS  
37 MTRS  
58 MTRS  
91 MTRS  
153 MTRS  
10  
4) Whenever possible cable terminations should be made below deck and with approved terminal  
devices;  
5) If a spare auxiliary fuse or circuit breaker is not available, one of the correct type and rating  
should be fitted and connected to a positive supply. It is advisable to locate a bus bar or main  
connection and avoid any direct connection to the supply:  
6) For 110/220v AC products, the following colour coding system should be used for the customer  
supply cable:  
Brown  
Blue  
- Live  
- Negative  
Green/Yellow - Earth  
Note: This equipment must be earthed.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation Guidelines  
A typical installation and connection routine for the L560RC 2/3Kw searchlight is as follows:  
Referring to wiring diagram C22978, a supply is fed to the control panel, which then provides a  
common feed to the motor gearbox and the searchlight.  
Cables required to be connected by the customer: -  
4 core 1.5mm2 cable from the Motor Gearbox to the Control Panel.  
12 core 0.5mm2 cable from the Motor Gearbox to the Control Panel.  
(Customer may need to provide a suitable junction box to extend these two cables – 3 metres  
supplied). The Mains cable to the Control Panel to be supplied by the customer.  
The searchlight head is pre-wired along with the connecting cable to the motor gearbox.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 - Operating Instructions  
This equipment is designed for use out of doors, in free air. Never place anything on, or cover the  
searchlight when in use as this may present a hazard.  
The searchlight can be remotely positioned via the joystick control panel, with the facility for  
movement up, down, left and right. The speed of movement depends on the more pressure applied  
to the joystick the faster the searchlight moves. When in the desired position the joystick should be  
released so that it returns to its’ home position, dead centre.  
The variable speed gearbox has a fast and slow setting. You activate this by switching the  
controller switch on the control panel then selecting fast or slow.  
The beam of the searchlight can be externally adjusted to give a variety of spreads. Using the  
focussing handle situated underneath the barrel head. The lampholder can be moved into the  
desired position, towards the front for spot or the rear for flood.  
The searchlight is fitted with a Breather Assembly. This ensures a steady airflow in order to prevent  
any vacuum forming within the barrel.  
The heaters specified on this equipment are self-regulating and will increase/decrease the heat as  
required.  
This product should not be used for any purpose other than for which it was designed. Any  
modifications to the product should not be undertaken without consulting the manufacturer.  
Setting to Work  
Safe service in use necessitates the strict observance of the following precautions.  
Any article fabricated from quartz or glass is inherently fragile and care should  
therefore be taken, at all times, when handling lamps;  
Eye protection must be worn when handling lamps that have been removed from their  
packaging materials. The protective jacket should not be removed from the lamp for  
safety reasons, as there is a remote possibility of the lamp shattering violently,  
especially if it is subjected to mechanical shock or vibration;  
Always isolate the equipment from the supply before inserting a lamp;  
Before inserting the lamp ensure that all contacts are clean. Contacts must be  
renewed at the slightest sign of corrosion. Sanding or filing down corroded areas is not  
recommended as this will only make the conducting surface between the pin and  
lampholder smaller, thus causing the lamp to overheat;  
Do not twist or bend the fused quartz bulb when fitting the lamp as mechanical  
stresses MUST be avoided;  
The lamp must be capable of unimpeded expansion when it warms up to operating  
temperature. Mechanical forces must not be applied to the fused quartz bulb;  
Before the protective jacket is removed, suitable protection must be worn i.e. face  
mask and gloves with wrist protection;  
Never touch the quartz bulb with bare hands, as fingerprints will make the glass cloudy  
and cause a severe loss of light. This may also cause recrystallisation and thus  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
weaken the bulb material. Should the bulb be inadvertently touched, remove  
fingerprints with methylated spirit and a clean, soft paper towel. The bulb should then  
be wiped with distilled water. NOTE: ALWAYS WEAR MASK AND GLOVES DURING  
CLEANING);  
In all circumstances the lamp manufacturers data should be referred to when dealing with lamps.  
When fitting the lamp:  
-
-
-
-
Always isolate the equipment from the supply when inserting a lamp;  
Ensure the circuit is suitably fused;  
Ensure the lamp is of the correct power rating and type;  
Check lampholder is in good condition. If the contacts show any sign of corrosion, replace the  
lampholder;  
-
Check the lampholder is in a good dry condition. Never allow water to collect in the lamp fitting  
or come into contact with the lamp.  
To fit the lamp:  
-
-
-
-
Remove the front bezel assembly by operating the safety catch and lifting the latch body;  
For easier access the light shield/spill ring may be removed by undoing the fasteners;  
Cut open one end of the protective sleeve surrounding the lamp;  
Using the sleeve to prevent the fingers coming into contact with the lamp, position the two pins  
above the holes in the lampholder;  
-
-
Gently push the lamp into the lampholder and remove the protective sleeve;  
Replace the light shield/spill ring and front bezel assembly, ensuring the safety catch is  
engaged.  
Testing  
Upon correct installation and connection to an electrical supply, the equipment can be tested in  
order to ensure its’ correct performance. A competent person with some knowledge of electrical  
equipment must carry out this work.  
Equipment required:  
Multi-meter with leads  
Ammeter  
Using the equation P=VI, the approximate power output of the equipment can be calculated in the  
following way:  
-
-
-
Using the multi-meter, take a voltage reading;  
Using the ammeter, take an amps reading from the live cable to the lamp;  
Multiply these figures together to give an approximate wattage (Power output).  
For example:  
Using a 240v 1000w Tungsten halogen lamp:  
Voltage reading = 240v ;Amps reading = 4 amps  
Therefore, Wattage = 240 x 4 = 960 watts  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7- Fault Finding  
All fault finding must be conducted by a competent person or qualified Electrical Engineer.  
Failure of Lamp to light  
Causes:  
1) Power not supplied;  
2) Fuse blown;  
3) Failed lamp  
Remedy:  
1) Check voltage at supply. If supply is not present the fault is at the customer supply. If power is  
present, see remedy 2;  
2) Check fuse for visual failure. If none noticeable check fuse for continuity using a multi-meter. If  
fuse found to be faulty, replace with new part and test equipment again for correct working  
order. If found to be working correctly see remedy 3;  
3) Firstly, check supply at lampholder connecting block (within searchlight barrel). If supply is  
present, disconnect unit from power supply before removing the lamp. If noticeable damage to  
filament is present, the lamp will have failed. The lamp can also be checked for continuity using  
a multi-meter. Replace lamp ensuring all precautions and instructions previously outlined in  
this manual are adhered to.  
NOTE: If a fault occurs on the pan and tilt gearbox, the unit should be returned to Francis  
Searchlights Limited for fault evaluation and repair.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8 - Maintenance and Servicing  
In order to prolong the service life and performance of your searchlight, the following maintenance  
guidelines are recommended:  
Maintenance checks should be conducted before very voyage or at least every three months;  
Before checking, disconnect the equipment from the supply;  
Visually inspect the condition of the equipment;  
Any major or minor structural damage should be rectified immediately in order to reduce  
sympathetic wear;  
After inspection it may be necessary to clean the inside of the searchlight. The following  
procedure should be adhered to:  
Remove the front bezel;  
Clean the front glass inside and out using a proprietary glass cleaner or metal  
polish;  
Clean the reflector if required;  
Ensure that the lampholder is free from corrosion or other damage;  
Check earthing point for conductivity;  
It is advisable to check all seals and gaskets for signs of degradation. Renew if necessary;  
Upon completing all maintenance requirements the searchlight should be tested for full working  
order (approximately 20 minutes).  
If in any doubt as to the correct servicing procedures to adopt please contact your  
distributor/agent or the manufacturer who will be able to advise the best course of action for  
your product.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9 - Wiring Diagram and General Assembly  
Drawing Number  
C22978  
Description  
Wiring Diagram Lite Range Variable Speed 20 Amp  
L560RC 2/3Kw 115/240v Variable Speed General Assembly drawing  
Control Panel Assembly  
A2651  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 - Spare Parts List  
The following spare parts can be ordered directly from the manufacturer:  
Part Number  
Description  
Searchlight Spares  
D1823  
115v 2Kw G38 Tungsten Halogen Lamp  
D4604  
220/240v 2Kw G38 Tungsten Halogen Lamp  
D9843  
115v 3Kw G38 Tungsten Halogen Lamp  
D22559  
220/240v 3Kw G38 Tungsten Halogen Lamp  
C23002-00  
C22347-00  
C20550-00  
C20881-00  
C20569-00  
C21051-00  
C22268-01  
C09868-00  
C16761-00  
C20281-00  
Selector Switch 20Amp – On/Off  
Joystick  
Latch  
Front Glass  
Front Glass Gasket  
Reflector  
Breather unit  
Lampholder G38  
A.V. mount  
Bellows  
Motor Gearbox Spares  
C20261-00  
Heater  
C22403-01  
C22287-00  
Pan Motor S/Assy  
Tilt Motor  
C22380-00  
C22382-00  
C22285-00  
C22289-00  
Microswitch no leaver  
Microswitch with leaver  
Speed Controller  
P.S.U  
C22381-00  
C21225-00  
Pedestal Top Sealing Gasket  
Pedestal Cover Gasket  
In order to prolong the life and performance of your product, we recommend that you only specify  
Francis Searchlights spare parts. This will ensure that any warranties on your equipment will not be  
invalidated.  
When ordering spare parts please contact the Sales Department at Francis Searchlights Limited.  
Please quote searchlight model and serial number at all times. This will enable a fast response to  
your spares’ requirements.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Peavey Guitar 410TXF User Manual
Peavey Music Mixer SRM 2410 User Manual
Philips Stereo System MCM595 User Manual
Pioneer Car Stereo System AVIC 80DVD User Manual
Plantronics Headphones W730 User Manual
Porter Cable Air Compressor CPL55GH8W User Manual
Powermate Portable Generator PMC401856 User Manual
Premier Sander HV 13 User Manual
ProForm Home Gym PFRX31071 User Manual
PYLE Audio Projector PRJHD66 User Manual