SD5 Series
Spectra II™ and
Spectra Lite™ Dome
Installation/
Operation Manual
C1487M-C (7/99)
®
U
®
L
LISTED
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • DataFAX (1-559) 292-0435
Download from Www.Somanuals.com. All Manuals Search And Download.
Section
Page
LIMIT STOPS ....................................................................................................41
PARK TIME MINUTES......................................................................................42
SCAN SPEED ...................................................................................................42
PATTERN LENGTH ..........................................................................................42
TROUBLESHOOTING ......................................................................................................43
BACK BOX ELECTRONIC ASSEMBLY REMOVAL .................................................45
MAINTENANCE ................................................................................................................45
DOME CLEANING ....................................................................................................45
SERVICE MANUAL ..................................................................................................45
SPECIFICATIONS.............................................................................................................46
REGULATORY NOTICES .........................................................................................50
WARRANTY AND RETURN INFORMATION ....................................................................50
LIST OF ILLUSTRATIONS
Figure
Page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
In-Ceiling Components ...................................................................................... 5
Back Box Parts ..................................................................................................5
Pendant Components ........................................................................................ 6
Compass Tool ....................................................................................................8
Conduit Fitting Installation ..................................................................................8
Installing Back Box .............................................................................................9
Fastening Back Box ...........................................................................................9
Wiring Diagram for Spectra II™ ........................................................................10
Wiring Diagram for Spectra Lite™ .................................................................... 11
Interconnect Door .............................................................................................12
Transformer .......................................................................................................13
Interconnect Circuit Board Electrical Connections for Spectra II™................... 13
Interconnect Circuit Board Electrical Connections for Spectra Lite™ ...............14
Switch Locations ...............................................................................................15
Lower Dome Installation, In-Ceiling Models ......................................................21
Lower Dome Installation, Pendant Models .......................................................22
Backlight ...........................................................................................................29
SD5 Series Dimension Drawing ........................................................................47
LIST OF TABLES
Table
Page
A
B
C
D
E
Video Coaxial Cable Wiring Distances.............................................................. 11
24 VAC Wiring Distances ..................................................................................12
Switch Settings for SW1 ...................................................................................15
Switch Settings for SW2 – P-Type Control .......................................................16
Switch Settings for SW2 – D-Type Control .......................................................17
Pelco Manual C1487M-C (7/99)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and
conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P
enclosure, it is designed for indoor use only and it must not be installed where
exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the
weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that
dangerous voltage constituting a
risk of electric shock is present
within this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
This symbol indicates that there
DO NOT OPEN.
are important operating and
maintenance instructions in the
literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
MEASURES DE SECURITE IMPORTANTES
Avant d’installer ou d’utiliser ce produit, les mesures de sécurité suivantes sont à prendre:
1. Toute installation et réparation devraient être entreprises par un technicien qualifié et
conformes au codes locaux.
2. A moins que cet equipement indique avoir un boitié agrée NEMA de type 3, 3R, 3S, 4,
4X, 6 ou 6P, il est uniquement conçu pour utilisation intérieure et ne peut donc pas
être en contact de pluie ou d’humidité.
3. Utiliser seulement les pièces de rechanges recommandées par Pelco.
4. Après toute installation ou réparation de la partie électrique de ce produit, une
résistance entre le courant et la partie exposée devrait être installée afin de vérifier
que la partie électrique n’aie pas été en contact d’un court circuit.
5. L’installation entreprise et le matériel utilisé devraient supporter quatre fois le poids du
boitié, de la tourelle, de la caméra, et de la lentille.
Ce produit et/ou le manuel pourrait inclurent les symbols suivants:
Ce symbol indique qu’un voltage
dangereux pouvant provoquer un
chock électrique est présant
dans cette unité.
CAUTION:
RISQUE DE CHOQUE ÉLECTRIQUE.
Ce symbol indique qu’il y a des
mesures d’installation et
NE PAS OUVRIR.
d’entretient importantes inclus
dans le manuel de cet équipement.
Nous vous prions de bien vous familiarisez avec la manuel avant d’entreprendre toute
installation.
4
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
IN-CEILING MODELS
The Spectra II™ dome and Spectra Lite™ dome shipping cartons contain three boxes, plus
the C1487M-C system manual that covers everything in the system (back box, dome drive,
and lower dome). Inspect each box to make sure all parts are present.
Back Box
1
1
Back box
Parts bag (refer to Figure 2)
1
1
1
1
4
Conduit fitting
Safety chain bracket
Lock nut
Compass tool
T-rail clip (clip, L-bracket, screw, lock washer and nut)
1
Installation/Operation Manual (C1488M-B)
Dome Drive
1
1
Dome drive
Installation/Operation Manual (C1489M-A for Spectra II™ or C1498M-A for Spectra Lite™)
Lower Dome
1
1
Acrylic lower dome with trim ring
Installation Instructions (C1457M-B)
BACK
BOX
COMPASS TOOL
SAFETY
BRACKET
DOME
DRIVE
CONDUIT FITTING
& LOCK NUT
LOWER
DOME
T-RAIL CLIP
Figure 1. In-Ceiling Components
Figure 2. Back Box Parts
Pelco Manual C1487M-C (7/99)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
PENDANT MODELS
The Spectra II™ dome and Spectra Lite™ dome shipping cartons contain three boxes, plus
the C1487M-C system manual that covers everything in the system (back box, dome drive,
and lower dome). Inspect each box to make sure all parts are present.
Back Box
1
1
1
Back box
Tube of pipe sealant
Installation/Operation Manual (C1488M-B)
Dome Drive
1
1
Dome drive
Installation/Operation Manual (C1489M-A for Spectra II™ or C1498M-A for Spectra Lite™)
Lower Dome
1
1
Acrylic lower dome with trim ring
Parts bag
1
1
2
1
O-ring
O-ring lubricant
Screw, 6-32 x 1/4" (black) or 6-32 x 5/16" (gray)
Tube of Loctite®
1
Installation Instructions (C1457M-B)
BACK
BOX
DOME
DRIVE
LOWER
DOME
Figure 3. Pendant Components
6
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
DESCRIPTION
Spectra II™ and Spectra Lite™ domes are capable of the following:
•
•
360° pan rotation
+2 to -92° tilt
•
•
preset positioning
variable speed
The in-ceiling models can be installed in hard ceilings or standard 2' x 2' (61 cm x 61 cm)
suspended ceilings. These models are for indoor installation only.
The pendant models can be installed indoors or outdoors. The outdoor models include a
sun shield and heater. The heater allows operation in temperatures down to -60°F (-51°C).
An integral receiver has a switch to select the type of control. The receiver supports
Coaxitron® and RS-422 control types.
The dome drive quickly disconnects from the back box for easy servicing or moving.
Spectra II™ models include either a high-resolution color or monochrome camera with a
16X optical, 8X electronic zoom lens for a total zoom ratio of 128X. Spectra Lite™ models
include a preset focus color CCD camera with a 12X zoom lens.
Spectra II™ models include additional features–such as zones, patterns, alarms, auxiliary
relays, and auto focus–that are not part of Spectra Lite™ models.
The Spectra II™ and Spectra Lite™ domes operate on 24 VAC.
MODELS
Each Spectra II™ and Spectra Lite™ system consists of one each: back box, dome drive,
and lower dome. Outdoor pendant systems include a sun shield and heater. Refer to
components below (in-ceiling or pendant) to determine your system configuration.
SPECTRA II™ PENDANT COMPONENTS
BB5A-PB
BB5A-PG
Black pendant-mount back box (CE, UL, cUL)
Light gray pendant-mount back box (CE, UL, cUL)
BB5A-PG-E Same as BB5A-PG except includes heater and sun shield (CE, UL, cUL)
DD5AC
DD5AC-X
DD5AM
Dome drive with color camera/lens, NTSC standard (FCC, UL, cUL)
Dome drive with color camera/lens, PAL standard (CE)
Dome drive with monochrome camera/lens, EIA standard (FCC, UL, cUL)
Dome drive with monochrome camera/lens, CCIR standard (CE)
Smoked lower dome (1/2 f-stop of light loss) for black pendant-mount dome
Clear lower dome for black pendant-mount dome
Chrome lower dome (2 f-stops of light loss) for black pendant-mount dome
Gold lower dome (2 f-stops of light loss) for black pendant-mount dome
Smoked lower dome (1/2 f-stop of light loss) for light gray pendant-mount dome
Clear lower dome for light gray pendant-mount dome
Chrome lower dome (2 f-stops of light loss) for light gray pendant-mount dome
Gold lower dome (2 f-stops of light loss) for light gray pendant-mount dome
Same as LD5PG-0 except includes heater
DD5AM-X
LD5PB-0
LD5PB-1
LD5PB-2
LD5PB-3
LD5PG-0
LD5PG-1
LD5PG-2
LD5PG-3
LD5PG-E0
LD5PG-E1
LD5PG-E2
LD5PG-E3
Same as LD5PG-1 except includes heater
Same as LD5PG-2 except includes heater
Same as LD5PG-3 except includes heater
SPECTRA II™ IN-CEILING COMPONENTS
BB5A-F
DD5AC
DD5AC-X
DD5AM
DD5AM-X
LD5F-0
LD5F-1
LD5F-2
LD5F-3
Indoor back box for flush mounting in a ceiling (CE, UL, cUL)
Dome drive with color camera/lens, NTSC standard (FCC, UL, cUL)
Dome drive with color camera/lens, PAL standard (CE)
Dome drive with monochrome camera/lens, EIA standard (FCC, UL, cUL)
Dome drive with monochrome camera/lens, CCIR standard (CE)
Smoked lower dome (1/2 f-stop of light loss)
Clear lower dome
Chrome lower dome (2 f-stops of light loss)
Gold lower dome (2 f-stops of light loss)
Pelco Manual C1487M-C (7/99)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECTRA LITE™ PENDANT COMPONENTS
BB5T-PB
BB5T-PG
Black pendant-mount back box (CE, UL, cUL)
Light gray pendant-mount back box (CE, UL, cUL)
BB5T-PG-E Same as BB5T-PG except includes heater and sun shield (CE, UL, cUL)
DD5T-C
Dome drive with color camera and lens, NTSC standard (FCC, UL, cUL)
Dome drive with color camera and lens, PAL standard (CE)
Smoked lower dome (1/2 f-stop of light loss) for light gray pendant-mount dome
Clear lower dome for light gray pendant-mount dome
Chrome lower dome (2 f-stops of light loss) for light gray pendant-mount dome
Gold lower dome (2 f-stops of light loss) for light gray pendant-mount dome
Same as LD5PG-0 except includes heater
DD5T-C-X
LD5PG-0
LD5PG-1
LD5PG-2
LD5PG-3
LD5PG-E0
LD5PG-E1
Same as LD5PG-1 except includes heater
SPECTRA LITE™ IN-CEILING COMPONENTS
BB5T-F
DD5T-C
DD5T-C-X
LD5F-0
LD5F-1
LD5F-2
LD5F-3
Indoor back box for flush mounting in a ceiling (CE, UL, cUL)
Dome drive with color camera and lens, NTSC standard (FCC, UL, cUL)
Dome drive with color camera and lens, PAL standard (CE)
Smoked lower dome (1/2 f-stop of light loss)
Clear lower dome
Chrome lower dome (2 f-stops of light loss)
Gold lower dome (2 f-stops of light loss)
INSTALLATION FOR IN-CEILING MODELS
To install the dome proceed through the steps in this section, beginning with the Ceiling and
Back Box Preparation section.
CEILING AND BACK BOX PREPARATION
HARD CEILING
NOTE: Use the SCA1
(structural ceiling adapter) if
additional support is required.
1. Locate the center point where you want to drill a hole in the ceiling. (The ceiling tile
cannot be thinner than 0.50 inch [1.27 cm] nor thicker than 1.75 inches [4.45 cm].)
2. Drill a hole in the ceiling using a 3/32-inch drill bit.
3. Remove the compass tool from the parts bag that came with the back box (refer to
Figure 4). Press the stud of the compass tool into the hole in the ceiling. Insert a pencil
in the hole in the other end of the compass and mark a circle on the ceiling.
CAUTION: Be
careful not to cut
outside of the line.
4. Carefully cut the circle out of the ceiling.
If you do, you may not be
able to install the back box.
Also, the trim ring may not
cover the hole.
5. Remove the conduit fitting, lock nut, and safety chain bracket from the parts bag and
attach them to the back box as shown in Figure 5.
Proceed to the Wiring section.
ATTACH SAFETY CHAIN HERE
Figure 4. Compass Tool
Figure 5. Conduit Fitting Installation
8
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
SUSPENDED CEILING
1. Remove the ceiling tile from the ceiling. (The ceiling tile cannot be thinner than 0.50
inch [1.27 cm] nor thicker than 1.75 inches [4.45 cm].)
CAUTION: The
ceiling tile must be
capable of support-
2. Locate the center point to drill a hole in the tile.
ing 16 pounds (7.3 kg) of
weight. If the ceiling tile will
not support this weight, or-
der the SD5-P metal panel.
3. Drill a hole in the ceiling tile using a 3/32-inch drill bit.
4. Remove the compass tool from the parts bag that came with the back box (refer to
Figure 4). Press the stud of the compass tool into the hole in the ceiling. Insert a pencil
in the hole in the other end of the compass and mark a circle on the ceiling.
CAUTION: Be
careful not to cut
outside of the line.
5. Carefully cut the circle out of the ceiling tile.
If you do, you may not be
able to install the back box.
Also, the trim ring may not
cover the hole.
6. Remove the conduit fitting, lock nut, and safety chain bracket from the parts bag and
attach them to the back box as shown in Figure 5.
7. Refer to Figure 6. Compress the spring clips on the back box with your hands and
push the back box through the hole in the ceiling tile. The spring clips will spring out
when they clear the ceiling tile.
8. Refer to Figure 7. Tighten the screws until the spring clips hold the back box firmly to
the ceiling tile. You will hear a clicking noise when the screws are tight. Do not install
the ceiling tile in the ceiling yet.
Proceed to the Wiring section.
HARD CEILING
OR
CEILING TILE
Figure 6. Installing Back Box
HARD CEILING
OR
CEILING TILE
T-RAIL CLIP
FOR
CEILING TILE
T-RAIL CLIP
FOR
CEILING TILE
Figure 7. Fastening Back Box
Pelco Manual C1487M-C (7/99)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING
Bring wiring to the back box opening in the ceiling. Do not attach the wiring to the back box.
You will do that later.
Refer to Figure 8 for the Spectra II™ wiring diagram or Figure 9 for the Spectra Lite™
wiring diagram.
Wiring is required for power, earth ground, and video.
Refer to Table A for the type of video coaxial cable to use.
Input power for the dome is 24 VAC only. Power consumption is 30 vA per dome for indoor
models and 75 vA for outdoor models. Refer to Table B to determine the size of wire to use.
NOTE: The dome will stop
operating if the voltage at
the dome drops below 18
VAC. It will turn back on
when the voltage exceeds
18 VAC.
Use a 24 VAC transformer with the following minimum vA:
40 vA per dome
100 vA per dome
For indoor models (without heater)
For outdoor models (with heater)
Refer to Figure 11 for wiring multiple domes from the same transformer.
SPECTRA II™ INTERCONNECT BOARD
CONTROL
(RS-422)
7
+5 to +24 VDC
EXTERNAL RELAY
(WIRING EXAMPLE)
Figure 8. Wiring Diagram for Spectra II™
10
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
If you are using a Coaxitron® controller, the control signals to operate the dome drive will
be transmitted over the video coax. The RS-422 control lines are not used.
If you are not using a Coaxitron® controller, use the RS-422 control lines. Use 22-gauge
wire.
Optional wiring for the Spectra II™ dome may be provided for alarm inputs (maximum of
seven), relay output (Aux 1), and auxiliary output (Aux 2). For more information about
wiring requirements, refer to the Back Box Connections section.
Proceed to the Back Box Installation section.
SPECTRA LITE™ INTERCONNECT BOARD
CONTROL
(RS-422)
Figure 9. Wiring Diagram for Spectra Lite™
Table A. Video Coaxial Cable Wiring Distances
Cable Type*
Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance. All-copper center conductor.
95% braided copper shield.
Pelco Manual C1487M-C (7/99)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a 10-percent
voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered
devices.)
Wire Gauge
20
18
16
14
12
10
30 vA
75 vA
94 ft
(28 m)
150 ft
(45 m) (72 m)
238 ft
380 ft
603 ft
960 ft
(115 m) (183 m) (292 m)
37 ft
(11 m)
60 ft 95 ft
(18 m) (29 m)
152 ft
(46 m)
241 ft
(73 m) (117 m)
384 ft
BACK BOX INSTALLATION
OPTIONAL PROCEDURE:
If you prefer, you may make
the wiring connections in-
side the back box before
installing the back box in the
ceiling.
1. Suspended Ceiling Only (for hard ceiling, go to step 2) – Install the ceiling
tile with the back box. Attach a T-rail clip on each side of the ceiling tile as shown in
Figure 7.
The clips for the ceiling tile are supplied with the back box. Attach the clip to the T-rail.
Fasten the L-bracket to the clip with the supplied screw, lock washer and nut.
2. Install a safety chain or cable (not supplied) that will support up to 16 pounds (7.3 kg).
Fasten one end to a support structure in the ceiling. Fasten the other end to the safety
chain bracket (refer to Figure 5) to prevent the back box from falling.
To do this, loosen the
thumbscrew inside the back
box and open the hinged
door (refer to Figure 10).
Bring the wiring into the
back box through the con-
duit fitting. Follow the steps
in the Back Box Connec-
tions section and then
3. Refer to Figure 10. Loosen the thumbscrew inside the back box and open the hinged
door.
4. Bring the wiring into the back box through the conduit fitting. If the wiring is inside
flexible conduit, connect the conduit to the fitting on the back box.
return to this section.
5. Hard Ceiling Only - Refer to Figure 6. Compress the spring clips on the back box
with your hands and push the back box through the hole in the ceiling. The spring clips
will spring out when they clear the ceiling. Refer to Figure 7. Tighten the screws until
the spring clips hold the back box firmly to the ceiling. You will hear a clicking noise
when the screws are tight.
CAUTION: The
ceiling must be ca-
pable of supporting
16 pounds (7.3 kg) of
Proceed to the Back Box Connections section.
weight. If the ceiling will not
support this weight, provide
additional reinforcement.
Also, a suitable safety chain
must be attached to the
back box to support up to 16
pounds (7.3 kg) in the event
of a ceiling failure.
THUMBSCREW
Figure 10. Interconnect Door
12
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
BACK BOX CONNECTIONS
WARNING: Make sure you
wire power to the outer con-
nectors of the terminal block
and ground to the middle
connector. Otherwise, you
could damage the dome.
Refer to Figure 12 or 13 to attach the wiring to the interconnect circuit board inside the back
box. Also refer to Figure 8 or 9 if necessary.
1. Earth Ground - Connect earth ground to the middle connector on the power
connector.
2. Power - Connect 24 VAC from the transformer to the outer terminals on the power
connector. It does not matter which lead goes to which terminal.
If you are wiring more than one dome from the same transformer, it is important to
wire the power connector in each dome the same way. That is, the wiring from one
side of the transformer must be connected to the same connector on each dome. If
you reverse the wiring, the cameras will be out of phase with each other and may
produce what appears to be vertical roll when switching between cameras. Refer to
Figure 11 for a wiring diagram.
DOME 1
POWER
DOME 2
POWER
3. Video - Connect the coaxial cable to the BNC video connector.
4. Control - If you are using a Coaxitron® controller, control signals will be transmitted
DOME 3
POWER
over the video coax.
If you are using RS-422 (P or D) control signals, connect the control lines from the
controller to the circuit board. Connect the wires as follows:
EXAMPLE: If each dome
requires 30 vA, three domes
require a transformer with a
minimum output of 120 vA
(refer to the Wiring section
for transformer require-
ments).
From controller
To 4-Wire terminal on circuit board
RX-
RX+
TX-
TX-
TX+
RX-
RX+
TX+
Figure 11. Transformer
Wiring
CONNECTOR
FOR OPTIONAL
TRANSLATOR
SUBASSEMBLY
HTR/FAN
VIDEO
RS-422
CONTROL
SIGNALS
1
RX–
RX+
TX–
TX+
2
DOME DRIVE
CONNECTOR
3
4
5
6
7
GND
NO
COM
NC
AUX 2
GND
AUX 1
FUSE
FAN
24 VAC
MIDDLE
PIN IS
GND
POWER
(24 VAC ONLY)
1.6 A
Figure 12. Interconnect Circuit Board Electrical Connections for Spectra II™
Pelco Manual C1487M-C (7/99)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
CONNECTOR
FOR OPTIONAL
TRANSLATOR
SUBASSEMBLY
HTR/FAN
VIDEO
RS-422
CONTROL
SIGNALS
RX–
RX+
TX–
TX+
DOME DRIVE
CONNECTOR
FUSE
FAN
24 VAC
MIDDLE
PIN IS
GND
POWER
(24 VAC ONLY)
1.6 A
Figure 13. Interconnect Circuit Board Electrical Connections for Spectra Lite™
NOTE: (Spectra II™
Only) Connect only a low
voltage device to the relay
output. Maximum current
rating of the relay contacts
is two amperes.
5. Heater/Fan - This is a factory connection for a heater on outdoor pendant models.
6. Alarm Inputs - (Spectra II™ Only) If you need alarm inputs, connect them. The
maximum number of alarm inputs is seven. Refer to Figure 8 for a typical wiring
example. Alarm inputs require a ground signal through a contact closure, such as a
switch.
7. AUX 1 - (Spectra II™ Only) An AUX 1 command from the controller will activate
the relay output. If you need the relay, wire it as required. Refer to Figure 8. The relay
contacts are shown when AUX 1 is inactive. When an AUX 1 command is issued, the
relay contacts will reverse and remain latched until a clear command is issued.
CAUTION:
(Spectra II™
Only) The maxi-
mum output of AUX 2 is 150
mA. If you connect a device
that draws more current,
you could destroy the output
transistor. The output is in-
tended to drive logic circuits
or low-current devices. If
higher current is required,
connect the output to a relay.
8. AUX 2 - (Spectra II™ Only) An AUX 2 command from the controller will place a
ground at the output of AUX 2 to operate the device connected to it. The output will
remain latched until a clear command is issued. If you need the AUX 2 output, wire it
as required. Refer to Figure 8 for typical wiring examples. The AUX 2 output is an
open collector transistor driver that can pass a maximum of 150 mA at 32 VDC. It is
capable of driving TTL logic circuits or low-current reed relays. If you use an external
relay, make sure that both the supply voltage and the current requirements are well
below the maximum of 32 VDC and 150 mA. Exceeding these values will cause
permanent damage to the dome. If you are not familiar with open collector drive
requirements, contact Pelco technical support for assistance.
CAUTION: Leave
adequate slack in
the wiring to permit
9. Close the door and tighten the thumbscrew securely.
Proceed to the Dome Drive section.
the door to open without
pulling on the connectors.
14
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
DOME DRIVE
NOTE: For Coaxitron® con-
trol, SW2 is not used and all
switches must be OFF.
1. Turn on power to the back box. The red LED should light to indicate power.
If the LED does not light, correct the trouble before proceeding. Refer to the Trouble-
shooting section.
If the light is operating, you may either leave the power on and continue with the
installation, or you may turn the power off before proceeding further.
2. Set the switches on the bottom of the dome drive. Refer to Figure 14 and Table C for
the settings for SW1.
Refer to Figure 14 and Tables D and E for the settings for SW2.
CAUTION: Make
sure the dome
drive locks into
3. Install the dome drive in the back box: Line up the green drive eject tab on the dome
drive with the green label on the back box and the red static tab with the red label on
the back box. Raise the dome drive into the back box and push on the ends of the
tabs until they both click into place on the back box.
place. Tug downward on the
dome drive with moderate
pressure to ensure that it
stays in place.
4. Turn on power, if it is not on. Listen for the fan operating. If the fan does not work, the
dome will overheat and shut down. If the fan does not work, return the back box
electronic assembly and dome drive to the factory for repair. Refer to the Back Box
Electronic Assembly Removal section.
Proceed to the Lower Dome section.
SW 1
ON
1
1
8
OFF
ON
8
OFF
SW 1
SW 2
ON
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
SW 2
OFF
Figure 14. Switch Locations
Table C. Switch Settings for SW1
Control Type
Switch Setting
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
SW1-6
SW1-7
SW1-8
Coaxitron®
P-Type Control
D-Type Control
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF*
OFF**
OFF**
OFF**
NOTES: Switches SW 1-3 through SW 1-6 MUST be OFF.
D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500 and CM8500
controllers or with American Dynamics control systems using the AD2083 Translator.
P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 control systems.
* OFF- Use with controllers that have more than 32 presets.
ON- Use with American Dynamics controllers (32 presets).
** OFF - Use with all control systems except CM9502 with variable speed keyboards.
For CM9502 with fixed speed keyboards, set switch OFF.
ON - Use with CM9502 with variable speed keyboards for smoother joystick control.
Pelco Manual C1487M-C (7/99)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Table D. Switch Settings for SW2 – P-Type Control
NOTES: For Coaxitron® controls, all switches on SW2 MUST be OFF.
For D-type control systems, refer to Table E.
Receiver Address
Switch Setting
SW2-3
SW2-1
SW2-2
SW2-4
SW2-5
1
2
3
4
5
6
7
8
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
9
OFF
OFF
ON
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
Baud Rate
Switch Setting
SW2-6
SW2-7
SW2-8
2400
4800
9600
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
16
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 – D-Type Control
NOTES: For Coaxitron® controls, all switches on SW2 MUST be OFF.
For P-type control systems, refer to Table D.
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
1
2
3
4
5
6
7
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
Continued on next page
Pelco Manual C1487M-C (7/99)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
89
90
91
92
93
94
95
96
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
97
98
99
ON
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
Continued on next page
18
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
Continued on next page
Pelco Manual C1487M-C (7/99)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 - D-Type Control (continued)
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
Continued on next page
20
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Switch Settings for SW2 - D-Type Control (continued)
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3
SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
LOWER DOME
1. Snap the clip on the end of the trim ring leash into the hole on the lip of the back box
next to one of the mounting screws.
2. Line up the snaps on the trim ring with the mounting screws on the back box. Snap the
trim ring into place on the plastic snap washers on the mounting screws.
Figure 15. Lower Dome Installation, In-Ceiling Models
Pelco Manual C1487M-C (7/99)
21
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION FOR PENDANT MODELS
PENDANT-MOUNT INSTALLATION
1. Install the pendant dome mount. Refer to the instructions supplied with the mount. If
the mount is outdoors, make sure it is properly sealed to keep moisture out.
2. Bring the wiring for the dome through the mount. Refer to the Wiring section.
3. Refer to Figure 10. Loosen the thumbscrew inside the back box and open the hinged
door.
4. Screw the back box into the mount and bring the wiring into the back box. If outdoors,
apply the provided pipe sealant to the threads on the back box.
5. Attach the wiring to the back box. Refer to the Back Box Connections section.
6. Install the dome drive. Refer to the Dome Drive section.
NOTE: If outdoors, apply
Duct Seal inside the pipe
portion of the back box to
prevent moisture or cold air
inside the mount from enter-
ing the unit and causing
condensation on the dome.
Make sure no moisture has
condensed inside the unit
before installing the lower
dome. Duct Seal can be
purchased through local
electrical supply houses.
7. Remove the O-ring and O-ring lubricant from the parts bag. Lightly apply lubricant to
the O-ring so that it is just moistened; do not use excess lubricant. Install the O-ring in
the groove on the trim ring of the lower dome.
8. Refer to Figure 16. Hanging down from the back box is a short cable (the trim ring
leash). Hold up the lower dome near the back box so that the trim ring leash touches
the lower dome. Line up the two screw holes in the trim ring of the lower dome with
the two screw holes in the back box. Place a finger on the edge of the trim ring where
the leash touches the lower dome.
9. Look inside the lower dome and note which of the six retainer screws is closest to your
finger. Remove this screw and attach the trim ring leash to the screw. Reinstall the
screw securely and make sure the leash will hold the lower dome.
LEASH
SCREW HOLES
(FRONT & BACK)
ATTACH LEASH
TO NEAREST
RETAINER
SCREW
Figure 16. Lower Dome Installation, Pendant Models
22
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
10. If you are installing an outdoor model, plug the two-pin heater connection in the lower
dome into the mating connector in the back box.
11. Remove the two screws and the tube of Loctite® from the parts bag. Apply a drop of
Loctite® to each screw.
12. Push the lower dome inside the back box, line up the screw holes, and install the two
screws.
SURFACE-MOUNT INSTALLATION
1. Use a hole saw to drill a hole in the ceiling where you want to hang the pendant dome.
2. Bring the wiring for the dome to the opening. Refer to the Wiring section.
NOTE: For hard ceilings,
such as concrete, where the
wiring must be installed in
surface-mounted conduit, use
the optional BB5-PCA-BK
(black) or BB5-PCA-GY
(gray) Pendant Conduit
Adapter.
3. Refer to Figure 10. Loosen the thumbscrew inside the back box and open the hinged
door.
4. Remove the gasket and the top mount from the back box by taking out the three
screws and lock washers.
5. Attach the back box to the ceiling using #8 hardware (not supplied).
6. Attach the wiring to the back box. Refer to the Back Box Connections section.
7. Install the dome drive. Refer to the Dome Drive section.
8. Remove the O-ring and O-ring lubricant from the parts bag. Apply lubricant to the
O-ring. Install the O-ring in the groove on the trim ring of the lower dome.
9. Refer to Figure 16. Hanging down from the back box is a short cable (the trim ring
leash). Hold up the lower dome near the back box so that the trim ring leash touches
the lower dome. Line up the two screw holes in the trim ring of the lower dome with
the two screw holes in the back box. Place a finger on the edge of the trim ring where
the leash touches the lower dome.
10. Look inside the lower dome and note which of the six retainer screws is closest to your
finger. Remove this screw and attach the trim ring leash to the screw. Reinstall the
screw securely and make sure the leash will hold the lower dome.
11. If you are installing an outdoor model, plug the two-pin heater connection in the lower
dome into the mating connector in the back box.
12. Remove the two screws and the tube of Loctite® from the parts bag. Apply a drop of
Loctite® to each screw.
13. Push the lower dome inside the back box, line up the screw holes, and install the two
screws.
OPERATION
The red LED in the interconnect door in the back box lights when power is turned on and
the fan operates to exhaust heat from inside the back box.
If you have an outdoor pendant model with a heater, the heater elements in the back box
turn on at 70°F (21°C) and turn off at 85°F (29°C). The heater element in the lower dome
turns on at 40°F (4°C) and turns off at 60°F (16°C). The fans in the back box operate
continuously.
Pelco Manual C1487M-C (7/99)
23
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER-UP DISPLAY
When the Spectra II™ dome or Spectra Lite™ dome is powered up or reset, the selected
protocol, revision number, and other information is displayed on the monitor. For example,
the screen might show the following information:
PELCO SPECT II 4.0
CONFIGURE DONE
Protocol C
NOTE: The dome will stop
operating if the voltage at
the dome drops below 18
VAC. It will turn back on and
go through its start-up rou-
tine when the voltage ex-
ceeds 18 VAC.
The information remains on the monitor until the dome is moved. The information displayed
depends on the selected protocol and the choice made on the menu for selectable power-
up mode, a feature that lets the dome resume a desired condition upon power-up. As a
default, the dome goes to a random position. (Refer to the Power-Up Mode section).
The control system protocol (C, D, or P) appears. C is for Pelco’s Coaxitron® control
systems. D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500 and
CM8500 controllers or with American Dynamics control systems using the AD2083
Translator. P-type control is RS-422 that is compatible with Pelco’s CM6700 and CM9750/
CM9760 control systems.
For the D and P protocols, the device address, baud rate, parity (N), number of data bits
(8), and number of stop bits (1) appears. For the D protocol, if the mode for 32 presets is
selected (SW1-7 is ON), “32 presets” appears.
If the CM9500 mode is selected (SW1-8 is ON), “CM9500 mode” appears.
PAN AND TILT FUNCTIONS
Use the joystick on your controller to control pan and tilt functions.
Pan and tilt operation is at a fixed speed with fixed-speed controllers. The speed is
determined by the controller.
Standard pan operation with variable-speed controllers will range from 0.5 to 80 degrees
per second, depending on the position of the joystick. In the turbo mode, pan speed will be
150 degrees per second. When performing preset operations, pan speed will be 250
degrees per second.
Standard tilt operation with variable-speed controllers will range from 0.5 to 40 degrees per
second, depending on the position of the joystick. When performing preset operations, tilt
speed will be 200 degrees per second. Turbo mode does not affect the tilt speed.
(Spectra II™ Only) If the proportional pan mode is enabled (refer to the Proportional
Pan section), the pan (and tilt) speed will depend on the amount of zoom. At telephoto
zoom settings, the pan (and tilt) speeds will be slower for a given amount of joystick
deflection than at wide zoom settings. This keeps the image from moving too fast on the
monitor when there is a large amount of zoom. This slowing does not happen when going
to a preset, but does occur in turbo mode when high zoom is selected.
AUTO FLIP
When the camera tilts downward and goes just beyond the vertical position, the dome
rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward as
long as you continue to hold the joystick in the down position. Once you let go of the
joystick after the dome rotates, joystick control returns to normal operation. The auto-flip
feature is useful for following a person who passes directly beneath the camera.
You can disable this feature in the auto flip programming menu. Refer to Auto Flip in the
Programming the Spectra II™ and Spectra Lite™ section.
SCAN SPEED
Scan speed is adjustable from 1 to 40 degrees per second through the programming menu.
24
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
ZOOM
SPECTRA II™ ZOOM
NOTE: (Spectra II™
The Spectra II™ dome can magnify an object up to 128 times. The dome has 16X of optical
zoom and 8X of electronic (digital) zoom for 128X total zoom. The amount of zoom can be
set for 16X, 32X, 64X, or 128X. Software controls the amount of zoom. Refer to the Zoom
Limit section to program the zoom limits.
Only) On some controllers
the zoom speed can be
changed. Refer to the docu-
mentation for your controller.
16X or 32X Zoom
Press the Zoom Tele button to magnify an object up to 16 or 32 times. Hold down the
button until you have the picture you want.
64X or 128X Zoom
1. Press the Zoom Tele button until the picture reaches 32X zoom.
2. Release the button.
3. Within one second, press the button again until you have the picture you want.
Zoom Wide
Press the Zoom Wide button to increase the field of view.
SPECTRA LITE™ ZOOM
The Spectra Lite™ dome can magnify an object up to 12 times (the dome has 12X of
optical zoom).
Zoom Telephoto - Press and hold down the Zoom Tele button until you have the picture
you want.
Zoom Wide - Press the Zoom Wide button to increase the field of view.
PRESET FUNCTIONS
NOTE: For American
The Spectra II™ dome is capable of going to 64 preset locations, each with a 20-character
label. The presets are numbered 1-32 and 35-66. The Spectra Lite™ dome can go to 32
presets. The presets are numbered 1-32.
Dynamics controllers with
only 32 presets, set switch
SW1-7 on the dome drive in
the ON position. When
SW1-7 is ON, preset
Refer to the documentation for your control system for programming presets.
When a preset operation is performed, the amount of error in moving to the pan and tilt
position is 1/2 degree. If you command the dome to go to an undefined preset, erratic
operation may result.
99 becomes 32
98 becomes 31
97 becomes 30
96 becomes 29
95 becomes 28
93 becomes 26
92 becomes 25
91 becomes 24
90 becomes 23
Presets 33 and 34 are fixed commands, meaning that you cannot program them. Preset 33
is the “flip” command, which will pan the dome drive 180 degrees from the position it is at.
Preset 34 is the “pan zero” command, which will direct the dome drive to the factory-
determined zero reference point.
The following presets are reserved for special functions. (An asterisk denotes
presets that apply to Spectra II only.)
If the limit stops are turned
off (refer to the Limit Stops
section), presets 23-26 can
be used as regular presets.
Preset
1
Function
Park
1-7*
33
34
90-93
95
96
Alarms, if used
Flip command
Pan zero command
Limit stops
Select camera programming menu
Stop a scan
97-99
Activate scanning
In the following sections, sometimes a number in parentheses follows a preset. This second
number is for 32-preset mode (conversion that lets Pelco’s presets work with American
Dynamics controllers). If you are using an American Dynamics controller, use the number in
parentheses.
Pelco Manual C1487M-C (7/99)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
RANDOM, FRAME, AND AUTO SCANNING
Program preset 97 (30) to start random scanning. Program preset 98 (31) to activate frame
scanning (three seconds of scanning followed by a three-second pause). Program preset
99 (32) to start auto (continuous) scanning.
Scan limit stops are controlled by software. Refer to the Limit Stops section to program the
scan limit stops.
When the dome reaches a scan limit stop, it will immediately reverse direction.
Program preset 96 (29) to stop a scan. Any pan/tilt or lens command also will stop a scan.
ZONES
(This section applies to Spectra II™ only.)
The Spectra II™ dome is capable of eight zones, each with a 20-character label. Depend-
ing on the controller, you can define the zone size and define any zone as “blanked” for
video when the camera pans into the zone area. If zone labels are turned off, the system
displays the message VIDEO BLANK to indicate the video is being blanked and is not
failing. (Refer to the Zone Blank section for instructions.) For other information on program-
ming zones, refer to the documentation for your control system.
PATTERNS
(This section applies to Spectra II™ only.)
NOTE: Changing the length
erases all stored patterns.
The Spectra II™ dome can do either one full pattern (1.5, 3, or 6 minutes long) or two half
patterns (.75, 1.5, or 3 minutes long). This pattern can consist of any standard pan and tilt
or lens command. Presets, flip, and turbo are not allowed in a pattern. Zone scan can be
enabled while running a pattern.
Refer to the documentation for your control system to program and run patterns.
ALARMS
(This section applies to Spectra II™ only.)
The Spectra II™ dome has seven alarm inputs, which can be designated as either high or
low priority through its programming menu. When an alarm is received, the dome does one
of the following:
•
Moves to the preset position that corresponds to the alarm number. For example, if
alarm 3 is activated, the dome moves to preset 3.
•
Runs a half pattern or full pattern as programmed in the Alarm Pattern submenu.
If any of presets 1-7 are not used for alarms, they can be used as regular presets.
However, if they are being used for alarms, they should not be used for anything else.
If an alarm input is programmed to run a pattern, the corresponding preset can be used as
a regular preset. For example, if alarm 3 is programmed to run a pattern, preset 3 can be
used as a regular preset.
There is no indication at the controller that an alarm has been received, other than the view
displayed on the monitor.
The high priority setting (if set on the programming menu) is significant when more than
one alarm is activated. If priority in alarms is not required, leave all alarms in the low setting.
•
If the activated alarm inputs have the same priority–all low or all high–then the
dome will sequence between the presets that correspond to the alarm numbers.
•
If the activated alarm inputs have different priorities–for example, one is high and
four are low–the dome goes only to the high. It remains fixed on the high and only
goes to the low after the high has been cleared.
26
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
In certain situations, the dome will respond as follows:
•
•
If a preset has not been set, but an alarm is connected: the dome will go to a factory
preset that will not be the desired position.
If one alarm is a preset and another is a pattern and both are received: the dome will
alternate between them.
An alarm clears by returning to its former (off) state.
Depending on choices made on the programming menu, the dome can respond to an alarm
by running one of the patterns below. (Refer to the Patterns section for more information.)
•
•
•
Run full pattern
Run half pattern 1
Run half pattern 2
When sequencing between presets, the dwell time depends on the time set on the Alarm
Dwell submenu for that preset. After the dwell time expires, the dome immediately does
one of the following:
•
If the resume feature was selected on the programming menu and there are no other
alarms activated, the dome resumes its prior activity. So, it might return to its previous
position or resume a scan or pattern.
•
If there are other alarms activated, the dome goes to them.
If you move the joystick to pan or tilt the dome, or if you issue a lens command while there
is an alarm, the pan and tilt or lens command overrides the alarm. Sixty seconds after the
last pan and tilt or lens command, the dome will return to the alarm preset if the alarm is
still active.
AUXILIARY OUTPUTS
(This section applies to Spectra II™ only.)
An AUX 1 command from the controller will activate the relay in the dome and operate the
device that is connected to the relay. The relay will remain latched until a clear command is
issued.
An AUX 2 command from the controller will place a ground at the output of AUX 2 to
operate the device that is connected to it. The output will remain latched until a clear
command is issued. Refer to the Back Box Connections section for precautions regarding
the use of the AUX 2 output.
The output relay can also be programmed so that it is activated when any alarm input is
activated. When latching (toggling) is selected on the programming menu, giving the AUX 1
command from the controller changes the state of the AUX (for example, if it was on, this
turns it off.) The clear command from the controller will turn the AUX off in the latching or
toggle mode.
PARK
If the Spectra IITM dome does not receive any commands for a specified period of time
(refer to the Park Time Minutes section), the dome will go to preset 1 and park. If the time
specified is zero, or if preset 1 has not been programmed, the dome will not park. The
default is zero minutes.
Pelco Manual C1487M-C (7/99)
27
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING THE SPECTRA II™ AND SPECTRA LITE™
The Spectra II™ and Spectra Lite™ domes can be programmed for the following functions.
(In this section, an asterisk denotes items that apply to Spectra II only.)
AGC (automatic gain control)
Alarm dwell*
Auto park time
Auxiliary relays*
Backlight compensation
Camera reset
Gain
Limit stops
Power-up mode
Proportional panning*
Scan speed
Alarm pattern*
Alarm priority*
Alarm resume*
Auto flip disable
Auto focus*
Sharpness
Shutter speed
Video zone blanking*
White balance
Zoom limit*
Pattern length*
Power line synchronization*
Auto iris
The main menu contains six secondary menus for Spectra II™ and three for Spectra Lite™.
•
•
•
Camera
Line Sync*
Power Up Mode
•
•
•
Aux*
Alarms, Zone Blank*
Other
Each secondary menu has submenus, which are structured as shown below.
1. Camera
First Camera Submenu
Backlight comp
Zoom limit*
Reset camera
Gain/AGC
Second Camera Submenu
Shutter speed
Auto focus mode*
Sharpness
Auto sharpness
Sharpness
AGC mode
Gain
White balance
Auto-iris
Auto white bal
Auto-iris mode
Auto-iris level
Auto-iris peak
Next (to second camera submenu)
R-B white bal
M-G white bal
Prev (to first camera submenu)
2. Line Sync*
Line sync*
Line sync phase*
3. Power Up
Power Up
4. Aux*
Aux 1 mode*
Aux 2 mode*
5. Alarm, Zone Blank*
Alarm resume*
Alarm dwell sec*
Alarm priority*
Alarm pattern*
Zone blank*
6. Other
Auto flip
Proportional pan*
Limit stops
Park time minutes
Scan speed deg/s
Pattern length*
The following sections explain how to program the Spectra II™ and Spectra Lite™ domes
using the menu choices.
28
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
MAIN MENU ACCESS
You can call up the main menu on your monitor by programming (setting or creating) preset
95 (28 if in 32-preset mode; refer to the Preset Functions section).
Programming preset 95 for Pelco’s controllers varies according to the type of controller you
are using. Instructions for programming preset 95 are given below for various Pelco
controllers.
CM6700
1. Enter the number of the Spectra II™ or Spectra Lite™ camera and press the CAM key.
2. Enter 95 and hold the PRESET key for two seconds.
3. In the Edit Preset menu, arrow to SET and press the ACK key. The main menu appears.
CM8500
1. Enter the number of the Spectra II™ or Spectra Lite™ camera and press the CAM key.
2. Highlight PRESET in the Camera menu and hold down the joystick button until the Set
Presets prompt appears.
3. Enter 95 and press the PRESET key. The main menu appears.
CM9500
1. Enter the number of the Spectra II™ or Spectra Lite™ camera and press the CAM key.
2. Press the SELECT key twice.
3. Highlight CAM in the Setup menu and press the SELECT key.
4. Highlight PRESET in the Camera menu and press the SELECT key.
5. Enter 95 and press the F1 key. The main menu appears.
CM9750
1. Turn the KEY SWITCH to the ON position.
2. Press the PROG key. PROGRAM appears on the LCD display.
3. Press the PRES key. The PRESET prompt appears.
4. Enter 95 and press the ENTER key. The main menu appears.
5. Turn the KEY SWITCH to the OFF position.
CM9760
1. In the default menu, select DEF. The Define Submenu appears.
2. Enter your four-digit PIN.
3. Enter 95 and select PRST. The main menu appears on the monitor.
4. Select the Quit icon to return to the default menu.
MPT9500
Standard Coaxitron® Mode
1. Enter 95 and press the PRESET SET key.
2. Position the asterisk in the YES row and press the F1 key. The main menu appears.
Extended Coaxitron® or RS-485 Mode
1. Enter 95 and press the PRESET SET key.
2. Press the F2 key. The main menu appears.
BACKLIGHT COMPENSATION
There are two backlight compensation modes: on and off.
NON-SENSITIVE AREA
Backlight compensation allows the Spectra II™ dome to compensate for bright light behind
the object you want to view. With backlight compensation On, the Spectra II™ dome will
use only the center 10 percent of the picture for adjusting the iris (refer to Figure 17). If
there is a bright light source outside of this area, it will wash out to white. The camera will
adjust the iris so that the object in the sensitive area is properly exposed.
SENSITIVE
AREA
To change the backlight compensation mode:
Figure 17. Backlight
1. Program Preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
Compensation
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
Pelco Manual C1487M-C (7/99)
29
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Backlight Comp.
5. Press the Iris Open button on your keyboard. A star will appear beside Backlight Comp
and the cursor will move to the right beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
ZOOM LIMIT
(This section applies to Spectra II™ only.)
The Spectra II™ dome can magnify an object up to 128 times. The dome has 16X of optical
zoom and 8X of electronic (digital) zoom for 128X total zoom. The amount of zoom can be
set for 16X, 32X, 64X, or 128X.
To change the zoom limit:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Zoom Limit.
5. Press the Iris Open button. A star will appear beside Zoom Limit and the cursor will
move to the right beside the current zoom limit.
6. Move the joystick up or down to choose the zoom limit.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
RESET CAMERA
Resetting the camera returns the following settings to their defaults. (An asterisk
denotes items that apply to the Spectra II™ only.)
Setting:
Auto-focus mode*
Default:
Auto*
Gain/AGC
AGC mode
Gain
Auto
No default setting
Backlight comp
Shutter speed
Auto-iris
Off
Auto
Mode
Auto
Level
Peak
Default value depends on type of camera
Default value depends on type of camera
White balance
Auto white balance
R-B white balance
M-G white balance
Sharpness
On
No default setting
No default setting
Auto sharpness
Sharpness
On
No default setting
When the camera is reset, the following settings are not changed: park time, auto flip
disable, limit stops; and for the Spectra II™ only, zoom limit and proportional panning.
30
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
Turning off power to the Spectra II™ and Spectra Lite™ domes does not reset the camera.
Camera settings are retained in memory, and when the power is turned back on, the
settings will be the same as they were when it was turned off.
To reset the camera:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Reset Camera.
5. Press the Iris Open button to reset the camera.
GAIN/AGC
AGC Mode
There are three AGC (Automatic Gain Control) modes: auto, on, and off.
In the auto mode, the Spectra II™ and Spectra Lite™ domes automatically adjust the gain–
the amount of amplification the camera places on its video information in order to obtain a
full 1-volt peak-to-peak video signal out. If the iris is manually opened to its wide-open
position and the picture is weak, the AGC can be turned off and the gain increased
manually to improve the picture. For instructions on how to do this, refer to the Auto Iris
section. When you close the iris, the AGC will turn back on automatically when the lens iris
starts closing.
In the on mode the AGC is on all the time.
In the off mode the AGC is off.
To change the AGC mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Gain/AGC.
5. Press the Iris Open button to enter the Gain/AGC submenu.
6. Move the joystick up or down to position the cursor beside AGC mode.
7. Press the Iris Open button on your keyboard. A star will appear beside AGC mode and
the cursor will move to the right beside the word Auto, On, or Off.
8. Move the joystick up or down to position the cursor beside Auto, On, or Off.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
Pelco Manual C1487M-C (7/99)
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Gain
The gain adjusts the signal level of the video output. Increasing the gain in low light
conditions will increase the level of noise in the picture.
To change the gain:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Gain/AGC.
5. Press the Iris Open button to enter the Gain/AGC submenu.
6. Move the joystick up or down to position the cursor beside Gain.
7. Press the Iris Open button on your keyboard. A star will appear beside Gain and the
cursor will move to the right beside the current gain setting (a numeric value).
8. Move the joystick up or down to change the gain. As you change the gain, the picture
on your monitor will get brighter or darker.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
AUTO IRIS
There are three settings for auto iris: mode, level, and peak.
To change the settings for auto iris:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Auto-Iris.
5. Press the Iris Open button on your keyboard. Another menu will appear with auto-iris
mode, level, and peak selections.
6. Move the joystick up or down to position the cursor beside one of the choices. Press
the Iris Open button on your keyboard.
MODE - The cursor moves to one of two choices: Auto or Off. In the Auto mode, the iris is
automatically adjusted to produce a constant video output as determined by the Level
setting below. In the Off mode, auto iris is disabled, and control is always manual. Move the
joystick up or down to toggle between Auto and Off. Press the Iris Open button to select the
choice, or press the Iris Close button if you do not want to change the setting.
LEVEL - The cursor moves to a numeric value, which the Spectra II™ dome uses to try to
maintain a certain light level. Changing the value of the Level setting will change the video
level to which the auto iris adjusts. This setting should be adjusted if the video level in the
auto iris mode is too bright or too dark. Move the joystick up or down to a value. Press the
Iris Open button to select the value, or press the Iris Close button if you do not want to
change the setting.
32
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
PEAK - The cursor moves to a numeric value. Increasing this value will cause the auto iris
circuit to react more to highlights or “peaks” in the picture. Decreasing this value will cause
it to use the average video level to adjust the iris. Move the joystick up or down to a value.
Press the Iris Open button to select the value, or press the Iris Close button if you do not
want to change the setting.
If auto iris is in the auto mode, it remains that way until you manually open or close the iris.
The dome will return to auto iris when it is panned or tilted more than 15 degrees.
If there is not enough light for a good picture when the iris is wide open, you can increase
the gain of the camera to improve the picture. To do this:
1. The AGC mode (AGC Mode section) must be in either the Auto or Off mode. The
following steps will not work if the AGC mode is On.
2. Hold down the Iris Open button until the iris is wide open.
3. Release the button.
4. Within one second, hold down the button again. This will start increasing the camera
gain. Hold down the button until a desirable picture is obtained or the maximum gain is
reached.
SHUTTER SPEED
There are nine electronic shutter speed settings:
Auto
1/100
1/120
1/500
1/1000
1/2000
1/4000
1/10,000
1/30,000
In the Auto setting the camera controls the shutter speed automatically.
Increasing the shutter speed lowers the light sensitivity, but rapidly moving objects will be
less blurred as the speed is increased.
To change the electronic shutter speed settings:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Next.
5. Press the Iris Open button to go to the next camera submenu.
6. Move the joystick up or down to position the cursor beside Shutter Speed.
7. Press the Iris Open button on your keyboard.
8. A star will appear beside Shutter Speed and the cursor will move to the right beside
the current shutter speed.
9. Move the joystick up or down to choose the shutter speed.
10. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
Pelco Manual C1487M-C (7/99)
33
Download from Www.Somanuals.com. All Manuals Search And Download.
AUTO-FOCUS MODE
(This section applies to Spectra II™ only.)
There are two auto-focus modes: auto and off.
If auto focus is in the auto mode, pressing the Focus Far or Focus Near button will place
the focus in the manual mode. The dome will return to auto focus if you pan or tilt the unit
or do a zoom function.
If the mode is set to off, the dome will operate in the manual mode with one exception. If
you issue a command to go to a preset, auto focus will turn on and remain on until you
press the Focus Far or Focus Near button.
To change the mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Next.
5. Press the Iris Open button to go to the next camera menu.
6. Move the joystick up or down to position the cursor beside Auto-Focus Mode.
7. Press the Iris Open button on your keyboard. A star will appear beside Auto-Focus
Mode and the cursor will move to the right beside the word Auto or Off.
8. Move the joystick up or down to toggle between Auto and Off.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
SHARPNESS
There are two modes for adjusting the sharpness of the picture: automatic and manual.
To change the mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Next.
5. Press the Iris Open button to go to the next camera menu.
6. Move the joystick up or down to position the cursor beside Sharpness.
7. Press the Iris Open button. Another menu will appear with the auto sharpness and
sharpness selections.
8. Move the joystick up or down to position the cursor beside one of the choices. Press
the Iris Open button.
34
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
AUTO SHARPNESS - The cursor moves to one of two choices: On or Off. Move the
joystick up or down to toggle between them. Press the Iris Open button to select the choice,
or press the Iris Close button if you do not want to change the setting.
SHARPNESS - The cursor moves to a numeric value. Move the joystick up or down to a
value. As you change the value, you will see the sharpness change. Press the Iris Open
button to select the value, or press the Iris Close button if you do not want to change the
setting. If the Auto Sharpness is on, it will change to off when you select a new value.
WHITE BALANCE (COLOR CAMERAS ONLY)
There are three settings for white balance: auto, red-blue, and magenta-green.
To change the white balance settings:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position the
cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Next.
5. Press the Iris Open button to go to the next camera submenu.
6. Move the joystick up or down to position the cursor beside White Balance.
7. Press the Iris Open button on your keyboard. Another menu will appear with the auto,
red-blue, and magenta-green selections.
8. Move the joystick up or down to position the cursor beside one of the choices. Press
the Iris Open button on your keyboard.
AUTO WHITE BALANCE - The cursor moves to one of two choices: Auto or Off. Move
the joystick up or down to toggle between them. Press the Iris Open button to select the
choice, or press the Iris Close button if you do not want to change the setting.
R-B WHITE BALANCE - The cursor moves to a numeric value. Move the joystick up or
down to a value. As you change the value, you will see the color change on your monitor.
Press the Iris Open button to select the value, or press the Iris Close button if you do not
want to change the setting. If Auto White Balance is on, it will change to off when you select
a new value.
M-G WHITE BALANCE - The cursor moves to a numeric value. Move the joystick up or
down to a value. As you change the value, you will see the color change on your monitor.
Press the Iris Open button to select the value, or press the Iris Close button if you do not
want to change the setting. If Auto White Balance is on, it will change to off when you select
a new value.
LINE SYNCHRONIZATION
(This section applies to Spectra II™ only.)
You can turn the line synchronization on or off.
If it is on, you can adjust the synchronization of the power line voltage so that it is in phase
with other cameras. If cameras are out of phase with each other, they may produce what
appears to be vertical roll when switching between cameras.
If it is off, the dome synchronizes to an internal clock.
To change the line synchronization settings:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
Pelco Manual C1487M-C (7/99)
35
Download from Www.Somanuals.com. All Manuals Search And Download.
2. If the cursor (>) is not beside Line Sync, move the joystick up or down to position the
cursor beside Line Sync.
3. Press the Iris Open button on your keyboard. Another menu will appear with the Line
Sync and Line Sync Phase selections.
4. Move the joystick up or down to position the cursor beside one of the choices.
LINE SYNC - The cursor moves to one of two choices: On or Off. Move the joystick up or
down to toggle between them.
Press the Iris Open button to select the choice. If you changed to Off, the camera may
reset itself as it adjusts to the new synchronization. If the camera resets, it will only affect
the line synchronization. It will not change any other camera parameters, such as auto
focus or auto iris.
Press the Iris Close button if you do not want to change the setting.
LINE SYNC PHASE - The cursor moves to a numeric value. Move the joystick up or
down to change the value.
Press the Iris Open button to select the choice. The value represents the phase angle in
tenths of a degree between 0 degrees and 359 degrees. For example, 900 is 90 degrees,
1200 is 120 degrees, and 2400 is 240 degrees. Press the Iris Open button on your
keyboard to select your choice. The Line Sync setting will change to On. The camera may
reset or the picture on your monitor may wiggle when you change the phase angle. If the
camera resets, it will only affect the line synchronization. It will not change any other
camera parameters, such as auto focus or auto iris.
Press the Iris Close button if you do not want to change the setting.
POWER-UP MODE
This feature lets the dome resume a desired condition following power-up. The menu
includes the following choices. (An asterisk denotes items that apply to the
Spectra II™ only.)
•
Default – On power-up, the dome goes through a configuration cycle and stops at
zero reference, showing “Configuration Done,” and address and mode settings on the
screen.
•
•
•
•
•
•
•
Park – The dome moves to preset 1 when the power-up sequence finishes. The only
text on the screen is the preset label (if any is programmed).
Scan Auto – The dome initiates scan mode when the power-up sequence finishes.
Again, there is no text.
Scan Frame – The dome initiates a frame scan when the power-up sequence
finishes.
Scan Rand – The dome initiates a random scan when the power-up sequence
finishes.
Full Pat* – The dome initiates its programmed pattern when the power-up sequence
finishes. The length can be set to 1.5, 3, or 6 minutes.
Half Pat 1* – The dome initiates the first half-pattern when the power-up sequence
finishes. The length can be set to .75, 1.5, or 3 minutes.
Half Pat 2* – The dome initiates the second half-pattern when the power-up
sequence finishes. The length can be set to .75, 1.5, or 3 minutes.
The default setting is Default.
36
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
To select the power-up mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Power Up Mode, move the joystick up or down to
position the cursor beside Power Up Mode.
3. Press the Iris Open button to enter the Power Up Mode submenu.
4. Move the joystick up or down to cycle through the selections. Stop on the item you
want to select.
5. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
AUX MODE
(This section applies to Spectra II™ only.)
This feature defines the output relay as either Normal (under control of the head end),
Latching (pressing the AUX key turns on the AUX and the next press of the AUX key turns it
off), or Alarm (any alarm input activates the AUX).
To change the AUX mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside AUX, move the joystick up or down to position the cursor
beside AUX.
3. Press the Iris Open button to enter the AUX submenu.
4. Move the joystick up or down to position the cursor next to either Aux 1 mode or Aux 2
mode.
5. Press the Iris Open button. The cursor will move to the right beside the word Normal,
Latching, or Alarm.
6. Move the joystick up or down to toggle between Normal, Latching, or Alarm.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
ALARM RESUME
(This section applies to Spectra II™ only.)
This mode lets the dome resume its previous activity (scan, pattern, or previous position)
after all alarms are cleared.
To change the alarm resume mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to
position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Alarm Resume.
5. Press the Iris Open button. The cursor will move to the right beside the word On or Off.
Pelco Manual C1487M-C (7/99)
37
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Move the joystick up or down to toggle between On or Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
ALARM DWELL
(This section applies to Spectra II™ only.)
This is the minimum time the Spectra II™ will stay at an alarm even if the alarm is present
for less than this amount of time.
To change the alarm dwell:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to
position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Alarm Dwell sec.
5. Press the Iris Open button. The cursor will move to the right beside the number of
seconds for the alarm dwell time.
6. Move the joystick up or down and hold to cycle through 1-200 seconds in one-second
increments.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
ALARM PRIORITY
(This section applies to Spectra II™ only.)
This feature lets you set alarm inputs as either high or low priority. A high priority alarm will
not release to a low priority alarm. Alarms will release or sequence between low priority
alarms only if no high priority alarm exists. (Refer to the Alarms section for more informa-
tion.)
To change alarm priority:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to
position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Alarm Priority.
5. Press the Iris Open button to enter the Alarm Priority submenu.
6. Move the joystick up or down to position the cursor beside the number of the alarm
input for which you want to set the priority.
7. Press the Iris Open button. The cursor will move to the right beside the word High or
Low.
8. Move the joystick up or down to toggle between the words High and Low.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
38
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
ALARM PATTERN
(This section applies to Spectra II™ only.)
NOTE: Pattern length is set
on the secondary menu en-
titled Other.
In response to an alarm, the Spectra II™ dome can do either one full pattern (1.5, 3, or 6
minutes long) or two half patterns (.75, 1.5, or 3 minutes long). You can choose one of the
following for each of the seven alarm inputs:
NOTE: To make the pattern
run to its end when an alarm
activates it, make alarm
dwell time longer than pat-
tern length. Therefore, if the
alarm goes away before the
end of the pattern, the pat-
tern will continue until the
dwell times out.
•
•
•
•
Full Pat (run full pattern)
Half Pat 1 (run half pattern 1)
Half Pat 2 (run half pattern 2)
No Pattern
To change the alarm pattern:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to
position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Alarm Pattern.
5. Press the Iris Open button to enter the Alarm Pattern submenu.
6. Move the joystick up or down to position the cursor beside the number of the alarm
input for which you want to set the pattern.
7. Press the Iris Open button. The cursor will move to the right beside the words Full Pat,
Half Pat 1, Half Pat 2, or No Pattern.
8. Move the joystick up or down to toggle between the choices.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
ZONE BLANK
(This section applies to Spectra II™ only.)
This feature lets you define any of eight zones as blanked for video when the camera pans
into the zone area. The choices are On and Off. On means video blanking is in effect. The
default is Off.
To change the blank zone setting:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to
position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Zone Blank.
5. Press the Iris Open button to enter the Zone Blank submenu.
6. Move the joystick up or down to position the cursor beside the number of the zone for
which you want to set the blank option.
7. Press the Iris Open button. The cursor will move to the right beside the word On or Off.
8. Move the joystick up or down to toggle between the words On and Off.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
Pelco Manual C1487M-C (7/99)
39
Download from Www.Somanuals.com. All Manuals Search And Download.
AUTO FLIP
There are two auto flip modes: on or off.
When the auto flip mode is on, the auto flip feature is enabled. When it is off, the feature is
disabled.
To change the auto flip mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position the
cursor beside Other.
3. Press the Iris Open button to enter the Other submenu.
4. Move the joystick up or down to position the cursor beside Auto Flip.
5. Press the Iris Open button. A star will appear beside Auto Flip and the cursor will move
to the right beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
PROPORTIONAL PAN
(This section applies to Spectra II™ only.)
There are two proportional pan modes: on or off.
When proportional pan mode is on, the proportional pan feature is enabled and the pan
(and tilt) speed will depend on the amount of zoom. At telephoto zoom settings, the pan
(and tilt) speeds will be slower for a given amount of joystick deflection than at wide zoom
settings. This keeps the image from moving too fast on the monitor when there is a large
amount of zoom. This slowing does not happen when going to a preset, but does occur in
turbo mode when high zoom is selected.
When the proportional pan mode is off, the feature is disabled and the pan speed will not
depend on the amount of zoom.
To change the proportional pan mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position the
cursor beside Other.
3. Press the Iris Open button to enter the Other submenu.
4. Move the joystick up or down to position the cursor beside Proportional Pan.
5. Press the Iris Open button. A star will appear beside Proportional Pan and the cursor
will move to the right beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
40
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMIT STOPS
There are two types of limit stops:
Manual limit stops
Scan limit stops
When manual limit stops are set, a manual (joystick) pan operation will stop when a limit
stop is reached.
When scan limit stops are set, the dome will reverse direction during random, frame, or
auto scanning when a limit stop is reached.
Limit stops are controlled by software. To set limit stops:
1. Turn on the limit stop mode.
2. Program the limit stops.
Turning Limit Stops On or Off
To change the limit stop mode:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position the
cursor beside Other.
3. Press the Iris Open button to enter the Other submenu.
4. Move the joystick up or down to position the cursor beside Limit Stops.
5. Press the Iris Open button. A star will appear beside Limit Stops and the cursor will
move to the right beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
Programming Limit Stops
MANUAL LIMIT STOPS
Refer to the documentation for your control system for programming presets, then do the
following:
NOTE: Programming
preset 90 (23) disables the
manual limit stops until
preset 91 (24) is set.
1. Make sure limit stops are turned ON (refer to the Limit Stops section), then exit the menu.
2. Push the joystick left until you reach the limit you want the camera to go to on the left.
3. Program preset 90 (23).
4. Push the joystick right to the limit you want the camera to go to on the right.
5. Program preset 91 (24).
Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.
SCAN LIMIT STOPS
Refer to the documentation for your control system for programming presets, then do the
following:
NOTE: On power-up, the
auto scan tilt angle will be
whatever angle the camera
was at when the right scan
limit was set.
1. Make sure limit stops are turned ON (refer to the Limit Stops section), then exit the menu.
2. Push the joystick left until you reach the limit you want the camera to go to on the left.
3. Program preset 92 (25).
4. Push the joystick right to the limit you want the camera to go to on the right.
5. Program preset 93 (26).
Setting presets 92 (25) and 93 (26) to the same point disables scan limit stops.
Pelco Manual C1487M-C (7/99)
41
Download from Www.Somanuals.com. All Manuals Search And Download.
PARK TIME MINUTES
This feature causes the dome to park at preset 1 after a programmed number of minutes of
control inactivity. The time can be set from 1 minute to 720 minutes (12 hours), or it can be
set to zero, which disables this feature.
NOTE: Preset 1 must be
programmed for the dome to
park.
To change the park time:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position the
cursor beside Other.
3. Press the Iris Open button to enter the Other submenu.
4. Move the joystick up or down to position the cursor beside Park Time Minutes.
5. Press the Iris Open button. A star will appear beside Park Time Minutes and the cursor
will move to the right beside the current park time.
6. Move the joystick up or down to change the park time.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
SCAN SPEED
The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan
modes: auto, random, and frame scan.
To change the scan speed:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position the
cursor beside Other.
3. Press the Iris Open button to enter the submenu entitled Other.
4. Move the joystick up or down to position the cursor beside Scan Speed deg/s.
5. Press the Iris Open button. The cursor will move to the right beside the number of
degrees.
6. Move the joystick up or down to toggle through the number of degrees (1-40) until you
reach the number you want. (If set on a low number, the scan will appear to barely
move but is still functioning.)
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
PATTERN LENGTH
(This section applies to Spectra II™ only.)
CAUTION: If the
length is changed,
You can set the pattern length to 1.5, 3, or 6 minutes or have two half-patterns of .75, 1.5,
or 3 minutes long.
all patterns that
were stored are erased.
To set the pattern length:
1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to
access the main menu (refer to the Main Menu Access section). The main menu will
appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position the
cursor beside Other.
42
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Press the Iris Open button to enter the submenu entitled Other.
4. Move the joystick up or down to position the cursor beside Pattern Length.
5. Press the Iris Open button. The cursor will move to the right beside the number of
minutes (1.5, 3, or 6).
6. Move the joystick up or down to toggle through the number of minutes (1.5, 3, or 6).
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
TROUBLESHOOTING
Symptom: Unit does not operate.
NOTE: The dome drive
contains no user-serviceable
parts. If there is a problem
with your dome drive, it
must be returned to Pelco
as a complete unit for
servicing.
1. Make sure your controller is trying to communicate with the unit and not another
camera.
2. Turn off power.
3. Remove the lower dome:
In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slots on the
trim ring and twist the screwdriver to pop loose the trim ring and lower dome.
Pendant Models - Remove the two screws that hold the trim ring to the back box.
Insert the flat blade of a screwdriver into the slots on the trim ring and twist the
screwdriver to free the lower dome from the back box.
4. Remove the dome drive: Push in on the green drive eject tab on the side of the dome
drive and gently rock the dome drive to release the latch. When the green latch
releases, pull the dome down.
5. Turn on power.
6. If the red power LED on the door of the interconnect circuit board in the back box does
not light, turn off power.
a. Open the door to the interconnect circuit board and check the fuse. Refer to
Figure 12 or 13 for the location of the fuse. If the fuse is bad, replace it. To order
a replacement fuse from Pelco, specify the part number FUS1.6-5X20FAST. This
is a 1.6-ampere fuse, 5 x 20 mm, fast blow.
b. If the fuse is good, turn on power and use a voltmeter to check if 24 VAC is
getting to the power connector on the interconnect circuit board. Refer to Figure
12 or 13 for the location of the AC power connector.
c. If there is 24 VAC to the power connector, turn off power and return the back box
electronic assembly to the factory for repair. Refer to the Back Box Electronic
Assembly Removal section.
d. If there is no voltage at the power connector, check your power supply.
7. If the red power LED is lit, turn off power.
a. Open the door to the interconnect circuit board and check that all connectors are
fully seated.
b. Make sure the wiring is correct between the unit and controller.
c. Close the door. Check the switch settings on the dome drive (refer to Tables C,
D, and E) and reinstall the dome drive.
Pelco Manual C1487M-C (7/99)
43
Download from Www.Somanuals.com. All Manuals Search And Download.
d. Turn on power. If the unit still does not operate, turn off power and replace the dome
drive with a unit that is good, if you have a spare. Check the switch settings on the
substitute dome drive before installing it. If you do not have a spare, return the dome
drive to the factory. Also return the back box electronic assembly. Refer to the Back
Box Electronic Assembly Removal section.
e. If you substituted a dome drive, turn on power. If the unit operates, the original dome
drive is bad. Return it to the factory. If the unit still does not operate, then the
interconnect board is bad. Return the back box electronic assembly to the factory;
refer to the Back Box Electronic Assembly Removal section.
Symptom: Fan does not operate.
1. Turn off power.
2. Remove the lower dome:
In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slots on the
trim ring and twist the screwdriver to pop loose the trim ring and lower dome.
Pendant Models - Remove the two screws that hold the trim ring to the back box.
Insert the flat blade of a screwdriver into the slots on the trim ring and twist the
screwdriver to free the lower dome from the back box.
3. Remove the dome drive: Push in on the green drive eject tab on the side of the dome
drive and gently rock the dome drive to release the latch. When the green latch
releases, pull the dome down.
4. Make sure the connector for the fan is fully seated.
5. Replace the dome drive. Turn on power. If the fan does not operate, return the back
box electronic assembly and dome drive to the factory for repair. Refer to the Back
Box Electronic Assembly Removal section.
Symptom: Alarms not cycling when more than one alarm is active
Reset all your alarm priorities to all LOW or all HIGH (refer to the Alarms section for an
explanation of alarm high/low priorities). To reset the alarm priorities, do the following:
1. Go to the Main Menu Access section and follow the instructions for accessing the
programming main menu.
2. Go to the Alarm Priority section and follow the instructions for setting the alarm priority.
Symptom: Alarms not going to preset
1. Check that the preset is defined.
2. Check that no higher priority alarm is activated.
3. Check that a pattern is not set for the affected alarm(s). If a pattern is set, the alarm
will run a pattern, not go to a preset. If a pattern (or patterns) is set, reset the
pattern(s) to NO PATTERN.
To reset a pattern, do the following:
1. Go to the Main Menu Access section and follow the instructions for accessing the
programming main menu.
2. Go to the Alarm Pattern section and follow the instructions for setting the alarm
pattern.
Symptom: Alarms not starting a pattern
Ensure that the pattern selected is valid. Any time you expect a pattern to execute, make
sure the pattern is recorded correctly and is valid.
Symptom: Motion problems
When troubleshooting motion problems on a system where alarms are connected, you can
eliminate alarms as a cause of the problem by disconnecting the alarm block in the back box.
44
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
BACK BOX ELECTRONIC ASSEMBLY REMOVAL
To remove the back box electronic assembly:
1. Turn off power.
2. Open the interconnect door and disconnect all wiring to the back box.
3. Use an 11/32 socket driver to remove the three 8-32 washers and nuts that hold the
electronic assembly to the back box. When the screws are removed, the interconnect
back box receptacle will drop down. It may be necessary to move the open intercon-
nect door past 90 degrees vertical toward the side of the back box to release the door
from the built-in grounding strip (and free the interconnect back box receptacle).
4. Remove the interconnect back box receptacle with the electronic components from the
back box.
MAINTENANCE
DOME CLEANING
Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch
the surfaces of the dome.
Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth
and cleaning agent that is safe for acrylic. Either liquid or spray cleaner/wax suitable for fine
furniture is acceptable.
Interior Surface (Except Chrome or Gold) - Clean the same as the exterior surface.
Interior Surface (Chrome or Gold) - The inside surface of a chrome or gold dome is
easily scratched. Use the following precautions to maintain the dome's surface.
a. Always handle the dome from the outside of its circular flange.
b. Never touch the coated inside surface. The acid in your fingerprints will eventually
etch the coating if the fingerprints are not carefully removed according to the recom-
mended cleaning procedure in item “e”.
c. If dust or other contaminants accumulate on the dome's interior, remove the debris
with compressed air. Compressed air cans are available from photographic equipment
or electronic supply dealers.
d. If heavy residue accumulates and cannot be removed with air pressure, rinse with
water and immediately dry with air pressure so that water spots will not remain. Avoid
wiping the coated surface with direct hand pressure - it will easily abrade unless
extreme care is taken. Once scratched, the dome cannot be recoated.
e. If internal wiping is necessary, avoid hand rubbing. Instead, make a wick as follows:
Use a very soft paper towel. Roll a section into a tightly wound tube. Tear the tube in
half, and wet the fuzzy end of the wick with a solution of isopropyl alcohol diluted with
water. Hold the dome with its opening facing downward and wipe the interior of the
dome with the wet end of the wick. Use a circular motion, starting from the outside and
spiraling into the center. Use a new wick for each two passes over the dome.
SERVICE MANUAL
If you need to service your unit, obtain a service manual in one of the following ways:
•
•
•
Call Pelco’s DataFAX service at 1-559-292-0435 and request document 214558.
Contact Pelco’s Literature Department and request service manual C1455SM-B.
Pelco Manual C1487M-C (7/99)
45
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
MECHANICAL
Construction
Back box:
Aluminum
Dome drive:
Lower dome:
Aluminum, ABS plastic
Acrylic
Cable Entry
In-Ceiling:
Pendant:
.75" (1.91 cm) conduit fitting
Through 1.5" (3.81 cm) NPT pendant mount
Pan Movement:
Vertical Tilt:
360° Continuous pan rotation
Unobstructed +2° to -92°
Manual Pan/Tilt
Speeds*
Pan:
0.5°-80°/sec manual operation, 150°/sec turbo
0.5°-40°/sec
Tilt:
Preset Speeds
Pan:
Tilt
250°/sec
200°/sec
* For variable-speed operation an appropriate controller is required. With fixed-speed
controllers, Spectra II™ and Spectra Lite™ pan speed is 30°/sec and tilt speed is 12°/
sec. The CM6700 controller with the KBD200 keyboard has programmable fixed speeds.
ELECTRICAL
Input Voltage:
18-30 VAC, 24 VAC nominal
30 vA
Input Power
In-ceiling:
Indoor pendant: 30 vA
Outdoor pendant: 75 vA
Fuse:
1.6 A
Relay Contacts
Type:
AUX 1
Form C
AUX 2 Output
Open collector transistor output
Voltage:
Low voltage (<40 V) 32 VDC maximum
Current:
2 A maximum
150 mA maximum
GENERAL
Environment
In-Ceiling:
Pendant:
Indoor only
Indoor/outdoor
Operating Range
In-Ceiling:
32° to 140°F (0° to 60°C) intermittent operation; 32° to 122°F (0° to
50°C) continuous operation
Pendant
Without Heater: 32° to 140°F (0° to 60°C) absolute maximum operating temperature;
32° to 122°F (0° to 50°C) sustained maximum operating temperature
With Heater*:
(Assumes no wind chill factor; for detailed test conditions, contact Pelco.)
Maximum operating temperature: 140°F (60°C) absolute maximum;
122°F (50°C) sustained maximum
Minimum operating temperature: -60°F (-51.11°C) absolute minimum;
minimal icing at -50°F (-45.56°C) sustained minimum; prevents icing at
-40°F (-40°C) sustained minimum; de-ices .1 inch (2.5 mm) within 3
hours after power-up
Dimensions:
See Figure 18
46
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
TOP PORTION OF BACK BOX
DOME IS SECURED
IS REMOVABLE FOR SURFACE TO CEILING BY
MOUNT APPLICATIONS
MOUNTING BRACKET
8.52
(21.64)
7.25 (18.13)
6.60 (16.76)
5.25
(13.34)
6.75
(17.15)
10.90
(27.69)
5.83
(14.80)
3.25
(8.26)
5.90 (14.99)
8.25 (20.96)
5.90
(14.99)
IN-CEILING DOME
PENDANT DOME
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
Figure 18. SD5 Series Dimension Drawing
Ratings:
Weight
NEMA Type 1–In-ceiling back boxes, all dome drives
NEMA Type 4–Pendant back boxes
IP 66–Pendant back boxes
Unit
Shipping
In-Ceiling
Back Box:
Dome Drive:
Lower Dome: .19 lb (.09 kg)
Pendant
2.6 lb (1.18 kg)
2.65 lb (1.20 kg)
4 lb (1.81 kg)
5 lb (2.27 kg)
1 lb (.45 kg)
Back Box:
2.85 lb (1.28 kg)
5 lb (2.27 kg)
Add 1.25 lbs (.57 kg) for heater and sun shield
Dome Drive:
2.65 lb (1.20 kg)
5 lb (2.27 kg)
Lower Dome: 1.30 lb (.59 kg)
2.20 lb (1.0 kg)
Add .25 lbs (.11 kg) for heater
* Assumes no wind chill factor; for detailed test conditions, contact Pelco.
CAMERAS
COLOR (Spectra II™ and Spectra Lite™)
Signal Format:
NTSC (Spectra II™ model DD5AC)
PAL (Spectra II™ model DD5AC-X)
NTSC (Spectra Lite™ model DD5T-C)
PAL (Spectra Lite™ model DD5T-C-X)
Scanning System:
Image Sensor:
2:1 interlace
1/4-inch interline transfer CCD
Pelco Manual C1487M-C (7/99)
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Effective Pixels
(NTSC Spectra II™):
(PAL Spectra II™):
768 (H) x 494 (V)
752 (H) x 582 (V)
(NTSC Spectra Lite™): 510 (H) x 492 (V)
(PAL Spectra Lite™):
500 (H) x 582 (V)
Horizontal Resolution
(Spectra II™):
(Spectra Lite™):
>450 TV lines
>330 TV lines
Lens
Minimum f-stop
(Spectra II™):
F1.4
(NTSC Spectra Lite™): F1.6-2.8
(PAL Spectra Lite™):
F1.6-2.5
Focal Length
(Spectra II™):
(Spectra Lite™):
4 mm to 64 mm optical
4 mm to 48 mm optical
Zoom Ratio
(Spectra II™):
(Spectra Lite™):
16X optical zoom, 8X electronic zoom
12X optical zoom
Horizontal Angle of View
(Spectra II™):
(Spectra Lite™):
47° (at 4 mm wide zoom), 3° (at 64 mm telephoto zoom)
47° (at 4 mm wide zoom), 4° (at 48 mm telephoto zoom)
MTBF:
>2 million cycles at room temperature (zoom, focus, iris)
Focus
(Spectra II™):
(Spectra Lite™):
Automatic and manual override
Manual with capability to focus when going to a preset position
Sensitivity
(Spectra II™ NTSC):
(Spectra II™ PAL):
1.5 lux at f1.4 at signal level of 40 IRE (NTSC), gain 22.0 dB
1.5 lux at f1.4 at 300 mV, gain 24.7 dB
(Spectra Lite™ NTSC): 4 lux at f1.6 at signal level of 40 IRE (NTSC), gain high
(Spectra Lite™ PAL):
Signal Process:
3 lux at f1.6 at 300 mV
DSP-3R
Sync System
(Spectra II™):
(Spectra Lite™):
AC line lock, phase adjustable via remote control*
Internal
White Balance:
Automatic with manual override*
Shutter Speed
(Spectra II™ NTSC):
(Spectra II™ PAL):
Automatic (electronic iris)/manual
1/60-1/30,000*
1/50-1/30,000*
(Spectra Lite™ NTSC): 1/100-1/30,000*
(Spectra Lite™ PAL):
1/100-1/30,000*
Iris Control:
(Spectra II™):
(Spectra Lite™):
Automatic with manual override*
Automatic with manual override*
Gain Control:
Automatic with manual override*
Video Output
(NTSC):
(PAL):
.714V ± .07V (100 IRE ± 10 IRE)
.7V ± .07V
Signal to Noise Ratio:
>46 dB
48
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
MONOCHROME (Spectra II™ Only)
Signal Format
EIA (model DD5AM)
CCIR (model DD5AM-X)
Scanning System:
Image Sensor
2:1 interlace
1/4-inch interline transfer CCD
>500 TV lines
Horizontal Resolution:
Effective Pixels
EIA:
CCIR:
768 (H) x 494 (V)
752 (H) x 582 (V)
Lens:
Minimum f-stop:
Focal Length:
Zoom Ratio:
Horizontal
Angle of View
MTBF:
F1.4
4 mm to 64 mm optical
16X optical zoom, 8X electronic zoom
47° (at 4 mm wide zoom), 3° (at 64 mm telephoto zoom)
>2 million cycles at room temperature (zoom, focus, iris)
Automatic with manual override
Focus:
Sensitivity
EIA:
.1 lux at f1.4, AGC gain 26.5 dB, signal level 40 IRE, without IR
cut filter
CCIR:
.1 lux at f1.4, AGC gain 29.5 dB, signal level 300 mV, without
IR cut filter
Signal Process:
Sync System:
DSP-3R
AC line lock, phase adjustable via remote control*
Shutter Speed:
EIA:
Automatic (electronic iris)/manual
1/60-1/30,000
CCIR:
1/50-1/30,000
Iris Control:
Automatic with manual override*
Automatic with manual override*
Gain Control:
Video Output
EIA:
CCIR:
.714V ± .07V (100 IRE ± 10 IRE)
.7V ± .07V
Signal to Noise Ratio:
>46 dB
* Manual control of camera setup functions can be done with CM6700, CM8500, CM9500,
CM9760 and MPT9500 controllers, but not with CM7500, MPT9000 or KBD9000
controllers.
(Design and product specifications subject to change without notice.)
Pelco Manual C1487M-C (7/99)
49
Download from Www.Somanuals.com. All Manuals Search And Download.
REGULATORY NOTICES
Note: This equipment has been tested and found to comply with the limits of a Class A
digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
WARRANTY AND RETURN INFORMATION
WARRANTY
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100
Pelco will repair or replace, without charge, any merchandise proved defective
in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide
the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Three years on Genex™ Series (multiplexers, server, and keyboard).
Two years on all standard motorized and fixed focal length lenses.
Two years on Esprit™, Legacy®, Intercept®, PV1000 Series, CM6700/
CM8500/CM9500/CM9750/CM9760 Matrix, Spectra®, DF5 Series and DF8
Fixed Dome products.
Two years on WW5700 series window wiper (excluding wiper blades).
Two years on cameras.
Six months on all pan and tilts, scanners or preset lenses used in continu-
If there is a dispute regarding the warranty of a product which does not fall
under the warranty conditions stated above, please include a written explana-
tion with the product when returned.
•
•
•
Ship freight prepaid to:
Pelco
ous motion applications (that is, preset scan, tour and auto scan modes).
300 West Pontiac Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid
to Pelco, Clovis, California. Repairs made necessary by reason of misuse, al-
teration, normal wear, or accident are not covered under this warranty.
Method of return shipment shall be the same or equal to the method by which
the item was received by Pelco.
RETURNS
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringe-
ment of any rights of any party or product liability, relating to the Products shall
not exceed the price paid by the Dealer to Pelco for such Products. In no event
will Pelco be liable for any special, incidental or consequential damages (includ-
ing loss of use, loss of profit and claims of third parties) however caused, whether
by the negligence of Pelco or otherwise.
In order to expedite parts returned to the factory for repair or credit, please call
the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization num-
ber (CA number if returned for credit, and RA number if returned for repair).
Goods returned for repair or credit should be clearly identified with the assigned
CA/RA number and freight should be prepaid.All merchandise returned for credit
may be subject to a 20% restocking and refurbishing charge.
Ship freight prepaid to:
Pelco
The above warranty provides the Dealer with specific legal rights. The Dealer
may also have additional rights, which are subject to variation from state to state.
300 West Pontiac Way
Clovis, CA 93612-5699
REVISION HISTORY
Manual #
Date
Comments
C1487M
7/98
Original version.
C1487M-A
11/98
Revised the manual to incorporate Spectra Lite™ material. Added material on CCIR and EIA monochrome cameras, and PAL
color camera. Revised material in Section 5.11.21.2, Programming Limit Stops. Revised Section 6.0, Troubleshooting. Changed
the fixed-speed controller rate in Section 8.0, Specifications.
C1487M-B
C1487M-C
2/99
Changed Spectra Lite™ model numbers, and added comments that the line sync feature is not functional for the DD5T-C
model of Spectra Lite™. Changed power specifications for indoor models from 25 vA to 30 vA and for outdoor models from 90
vA to 75 vA. Revised maximum temperature operating ranges. Revised color camera specifications.
Changed auto iris material to include Spectra Lite™ as well as Spectra II™.
Added a note relating to running patterns when an alarm activates. Changed the preset tilt speed from 100 to 200 degrees/
second. Added model number and specifications for Spectra Lite™ PAL camera. Revised manual to new format.
3/99
7/99
® Pelco and the Pelco logo are registered trademarks of Pelco.
© Copyright 1999, Pelco. All rights reserved.
50
Pelco Manual C1487M-C (7/99)
Download from Www.Somanuals.com. All Manuals Search And Download.
|