Pelco Home Security System SD5TAC User Manual

®
SD5TAC Series  
Spectra Lite™  
Dome Systems  
Operation and  
Programming Manual  
C2422M (5/00)  
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150  
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFEGUARDS AND WARNINGS  
Prior to installation and use of this product, the following WARNINGS should be observed.  
1. Installation and servicing should only be done by qualified service personnel and  
conform to all local codes.  
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P  
enclosure, it is designed for indoor use only and it must not be installed where  
exposed to rain and moisture.  
3. Only use replacement parts recommended by Pelco.  
4. After replacement/repair of this unit’s electrical components, conduct a resistance  
measurement between line and exposed parts to verify the exposed parts have not  
been connected to line circuitry.  
5. The installation method and materials should be capable of supporting four times the  
weight of the enclosure, pan/tilt, camera and lens combination.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage  
constituting a risk of electric shock is present  
within this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are important  
operating and maintenance instructions in the  
literature accompanying this unit.  
Please thoroughly familiarize yourself with the information in this manual prior to installation  
and operation.  
MEASURES DE SECURITE IMPORTANTES  
Avant d’installer ou d’utiliser ce produit, les mesures de sécurité suivantes sont à prendre:  
1. Toute installation et réparation devraient être entreprises par un technicien qualifié et  
conformes au codes locaux.  
2. A moins que cet equipement indique avoir un boitié agrée NEMA de type 3, 3R, 3S, 4,  
4X, 6 ou 6P, il est uniquement conçu pour utilisation intérieure et ne peut donc pas  
être en contact de pluie ou d’humidité.  
3. Utiliser seulement les pièces de rechanges recommandées par Pelco.  
4. Après toute installation ou réparation de la partie électrique de ce produit, une  
résistance entre le courant et la partie exposée devrait être installée afin de vérifier  
que la partie électrique n’aie pas été en contact d’un court circuit.  
5. Linstallation entreprise et le matériel utilisé devraient supporter quatre fois le poids du  
boitié, de la tourelle, de la caméra, et de la lentille.  
Ce produit et/ou le manuel pourrait inclurent les symbols suivants:  
Ce symbol indique qu’un voltage  
dangereux pouvant provoquer un chock  
CAUTION:  
électrique est présant dans cette unité.  
RISQUE DE CHOQUE ÉLECTRIQUE.  
NE PAS OUVRIR.  
Ce symbol indique qu’il y a des mesures  
d’installation et d’entretient importantes  
inclus dans le manuel de cet équipement.  
Nous vous prions de bien vous familiarisez avec la manuel avant d’entreprendre toute in-  
stallation.  
Pelco Manual C2422M (5/00)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
POWER-UP DISPLAY  
When the Spectra Lite™ dome is powered up, the selected protocol, revision number, and  
other information is displayed on the monitor. For example, the screen might show the  
following information:  
The information displayed depends on the selected  
protocol (C, D, or P) and the menu selection for power-  
PELCO SPECTRA LITE  
up mode. (Refer to the Power-Up Mode in the  
CONFIGURE DONE  
Programming section).  
Protocol C  
The information remains on the monitor until the dome  
is moved.  
HOW TO OPERATE YOUR SPECTRA LITE DOME  
Operation  
Pan and Tilt  
Scanning  
How to Control  
Move joystick left/right and up/down.  
Stop Scan  
Preset 96  
Preset 97  
Preset 98  
Preset 99  
Random Scan  
Frame Scan  
Auto Scan  
Zoom Far  
To zoom far, do the following:  
1. Press the Zoom Tele button or turn the joystick clockwise until you have the picture you want or you  
reach the zoom limit.  
2. Release the button or joystick.  
Zoom Wide  
Presets  
Press the Zoom Wide button or turn the joystick counterclockwise.  
Refer to the documentation supplied with the controller.  
Auto Flip  
Turn on or off in the programming menu. Refer to the Programming Guide in the Programming section.  
For more information, refer to Operating Notes.  
4
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING NOTES  
PAN AND TILT FUNCTIONS  
Controller Type  
Fixed speed  
Variable speed  
Turbo Mode  
Pan  
Tilt  
Speed determined by controller  
0.5 to 80° per second, depending on joystick position  
150° per second  
Speed determined by controller  
0.5 to 40° per second, depending on joystick position  
200° per second  
Preset Mode  
250° per second  
Does not affect the tilt speed  
AUTO FLIP  
When the camera tilts downward and goes just beyond the vertical position, the dome  
rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward as  
long as you continue to hold the joystick in the down position. Once you let go of the joystick  
after the dome rotates, joystick control returns to normal operation. The auto-flip feature is  
useful for following a person who passes directly beneath the camera. Refer to Auto Flip in  
the Programming section.  
SCAN SPEED  
Scan speed is adjustable from 1 to 40 degrees per second through the programming menu.  
PRESET FUNCTIONS  
The Spectra Lite dome can go to 32 presets. The presets are numbered 1-32. Refer to the  
documentation for your control system for programming presets.  
NOTE: For American  
Dynamics controllers with  
only 32 presets, set switch  
SW1-7 on the dome drive in  
the ON position. When  
SW1-7 is ON, preset  
When a preset operation is performed, the amount of error in moving to the pan and tilt  
position is 1/2 degree. If you command the dome to go to an undefined preset, erratic  
operation may result.  
Presets 33 and 34 are fixed commands, meaning that you cannot program them. Preset 33  
is the “flip” command, which will pan the dome drive 180 degrees. Preset 34 is the “pan zero”  
command, which will direct the dome drive to the factory-determined zero reference point.  
99 becomes 32  
98 becomes 31  
97 becomes 30  
96 becomes 29  
95 becomes 28  
93 becomes 26  
92 becomes 25  
91 becomes 24  
90 becomes 23  
RANDOM, FRAME, AND AUTO SCANNING  
Call preset 97 (30) to start random scanning. Call preset 98 (31) to activate frame scanning  
(three seconds of scanning followed by a three-second pause). Call preset 99 (32) to start auto  
(continuous) scanning. Scan limit stops are controlled by software. Refer to the Limit Stops  
section to program the scan limit stops. When the dome reaches a scan limit stop, it reverses  
direction. Call preset 96 (29) to stop a scan. Any pan/tilt or lens command also will stop a scan.  
If the limit stops are turned  
off (refer to the Limit Stops  
section), presets 23-26 can  
be used as regular presets.  
PARK  
If the dome does not receive any commands for a specified period of time (refer to Park  
Time Minutes in the Programming section), the dome will go to preset 1 and park. If the  
time specified is zero, or if preset 1 has not been programmed, the dome will not park.  
The default is zero minutes.  
AUTO IRIS  
If auto iris is in the auto mode, it remains that way until you manually open or close the iris.  
The dome will return to auto iris when it is panned or tilted more than 15 degrees. If there is  
not enough light for a good picture when the iris is wide open, you can increase the gain of  
the camera to improve the picture.  
To increase the gain:  
1. Hold down the Iris Open button until the iris is wide open.  
2. Release the button.  
3. Within one second, hold down the button again. This starts increasing the camera  
gain. Hold down the button until a desirable picture is obtained or the maximum gain is  
reached.  
Pelco Manual C2422M (5/00)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROGRAMMING  
Programming Guide - Spectra Lite  
1. Access main menu (preset 95).  
2. Make main menu selections.  
Joystick: Move up or down to position cursor or  
to toggle between selections.  
Iris Open: Enter  
Gain/AGC Menu  
Iris Close: Cancel  
AGC mode  
Gain  
Exit  
Auto  
10  
Camera Menu  
Backlight comp  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
Auto-Iris Menu  
Exit  
Auto-iris mode  
Auto-iris level  
Exit  
Auto  
180  
Sharpness Menu  
Line Sync Menu  
MAIN MENU  
Sharpness  
Exit  
5
Line sync  
Line sync phase  
On  
0
Next Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
Exit  
Shutter speed  
Auto focus mode Auto  
<Sharpness>  
<White balance>  
Prev (back to prev. menu)  
Exit  
Auto  
EXIT  
White Balance Menu  
Power-Up Menu  
Auto white bal  
White bal hue  
Exit  
Auto  
26  
Power Up  
Exit  
Default  
PRESETS  
The following presets are  
reserved for special functions.  
Preset  
1
Function  
Park  
Other Menu  
33  
34  
Flip command  
Pan zero  
command  
Auto flip  
Limit stops  
Park time minutes  
Scan speed deg/s 25  
Exit  
On  
On  
0
90-91  
92-93  
95  
Manual limit stops  
Scan limit stops  
Select camera  
programming  
menu  
96  
97  
98  
99  
Stop a scan  
Random scanning  
Frame scanning  
Start auto  
For detailed instructions, refer to the following sections.  
Menu items are listed alphabetically.  
scanning  
6
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSING MAIN MENU (PRESET 95)  
You can call up the main menu on your monitor by programming (setting or creating) preset  
95 (28 if in 32-preset mode).  
NOTE: For American  
Dynamics controllers with  
only 32 presets, set switch  
SW1-7 on the dome drive in  
the ON position. When  
SW1-7 is ON, preset  
Programming preset 95 for Pelco’s controllers varies according to the type of controller you  
are using. Instructions for programming preset 95 are given below for various Pelco  
controllers.  
CM6700  
99 becomes 32  
98 becomes 31  
97 becomes 30  
96 becomes 29  
95 becomes 28  
93 becomes 26  
92 becomes 25  
91 becomes 24  
90 becomes 23  
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.  
2. Enter 95 and hold the PRESET key for two seconds.  
3. In the Edit Preset menu, arrow to SET and press the ACK key. The main menu appears.  
KBD200/KBD300/KBD300V (Direct Mode Only)  
1. Enter 95.  
2. Hold the PRESET key (approximately 5 seconds) until the main menu appears on the  
screen.  
CM8500  
If the limit stops are turned  
off (refer to the Limit Stops  
section), presets 23-26 can  
be used as regular presets.  
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.  
2. Highlight PRESET in the Camera menu and hold down the joystick button until the Set  
Presets prompt appears.  
3. Enter 95 and press the PRESET key. The text editor appears. Select ENTER and the  
main menu appears.  
CM9500  
1. Enter the number of the Spectra II or Spectra Lite camera and press the CAM key.  
The Main menu appears.  
2. Highlight SETUP in the Main menu and press the SELECT key.  
3. Highlight CAM in the Setup menu and press the SELECT key.  
4. Highlight PRESET in the Camera menu and press the SELECT key.  
5. Enter 95 and press the F1 key. The main menu appears.  
CM9750  
1. Turn the KEY SWITCH to the ON position.  
2. Press the PROG key. PROGRAM appears on the LCD display.  
3. Press the PRES key. The PRESET prompt appears.  
4. Enter 95 and press the ENTER key. The main menu appears.  
5. Turn the KEY SWITCH to the OFF position.  
CM9760  
1. Press the ESCAPE key to open the Main menu. Select DEF. The Define Menu appears.  
2. Enter your four-digit PIN if this is your first time entering this mode.  
3. Enter 95 and select PRST. The main menu appears on the monitor.  
4. Select the Quit icon to return to the default menu.  
KBD4000/KBD4002/KBD4000V  
1. Press the SPOT MONITOR key.  
2. Enter 95, then hold the PRESET key (approximately five seconds) until the main menu  
appears on the screen.  
MPT9500  
Standard Coaxitron Mode  
1. Enter 95 and press the PRESET SET key.  
2. Position the asterisk in the YES row and press the F1 key. The main menu appears.  
Extended Coaxitron or RS-485 Mode  
1. Enter 95 and press the PRESET SET key.  
2. Press the F2 key. The main menu appears.  
Pelco Manual C2422M (5/00)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUTO FLIP  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Limit stops  
Park time minutes  
Scan speed deg/s 25  
Exit  
On  
On  
0
<Line Sync>  
<Power Up>  
<Other>  
EXIT  
There are two auto flip modes:  
On - Auto flip mode is enabled.  
Off - Auto flip mode is disabled.  
To change the auto flip mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Auto Flip.  
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.  
6. Move the joystick up or down to toggle between On and Off.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
AUTO FOCUS MODE  
Main Menu  
Camera Menu  
Next Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
Backlight comp  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
Shutter speed  
Auto focus mode Auto  
<Sharpness>  
<White balance>  
Prev (back to prev. menu)  
Exit  
Auto  
EXIT  
Exit  
There are two auto focus modes:  
Auto - If auto focus is in the auto mode, pressing the Focus Far or Focus Near button  
will place the focus in the manual mode. The dome will return to auto focus if  
you pan or tilt the unit or do a zoom function.  
Off - If the mode is set to off, the dome will operate in the manual mode with one  
exception. If you issue a command to go to a preset, auto focus will turn on and  
remain on until you press the Focus Far or Focus Near button.  
To change the mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside Auto Focus Mode.  
7. Press the Iris Open button. The cursor moves to the right, beside the word Auto or Off.  
8. Move the joystick up or down to toggle between Auto and Off.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
NOTE: Auto focus is auto-  
matically turned off when  
the shutter time is longer  
than 1/8 of a second.  
8
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUTO IRIS  
Main Menu  
Camera Menu  
Auto-Iris Menu  
Backlight comp  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
<Camera>  
Auto-iris mode Auto  
<Line Sync>  
<Power Up>  
<Other>  
Auto-iris level  
Exit  
180  
EXIT  
Exit  
The following are the settings for auto iris:  
Mode  
Level  
To change the settings for auto iris:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Auto-Iris.  
5. Press the Iris Open button. The Auto Iris menu appears.  
6. Position the cursor (>) and select one of the following settings:  
MODE - The cursor moves to one of two choices:  
Auto - The iris is automatically adjusted to produce a constant video output as deter-  
mined by the Level setting.  
Off - Auto iris is disabled, and control is always manual.  
Move the joystick up or down to toggle between Auto and Off. Press the Iris Open  
button to select the choice, or press the Iris Close button if you do not want to change  
the setting.  
LEVEL - The cursor moves to a numeric value, which the dome uses to try to  
maintain a certain light level. Changing the value of the Level setting will change the  
video level to which the auto iris adjusts. This setting should be adjusted if the video  
level in the auto iris mode is too bright or too dark. Move the joystick up or down to a  
value. Press the Iris Open button to select the value, or press the Iris Close button if  
you do not want to change the setting.  
Pelco Manual C2422M (5/00)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
BACKLIGHT COMPENSATION  
Main Menu  
Camera Menu  
Backlight comp  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
EXIT  
Exit  
There are two backlight compensation modes:  
On - The dome uses the center 10 percent of the picture to adjust the iris. If there is a  
bright light source outside of this area, it will wash out to white. The camera will  
adjust the iris so that the object in the sensitive area is properly exposed.  
Off - Backlight compensation is not activated.  
To change the backlight compensation mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
NON-SENSITIVE AREA  
3. Press the Iris Open button to enter the Camera menu.  
SENSITIVE  
AREA  
4. Position the cursor (>) beside Backlight Comp.  
5. Press the Iris Open button. The cursor moves to the  
right, beside the word On or Off.  
6. Move the joystick up or down to toggle between On  
and Off.  
7. SELECT - Press the Iris Open button on your key-  
board to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
GAIN/AGC  
Main Menu  
Camera Menu  
Gain/AGC Menu  
Backlight comp  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
<Camera>  
AGC mode  
Gain  
Exit  
Auto  
10  
<Line Sync>  
<Power Up>  
<Other>  
EXIT  
Exit  
Gain - The amount of amplification the camera places on its video information in order to  
obtain a full 1-volt peak-to-peak video signal out.  
AGC - Automatic Gain Control.  
AGC MODE  
There are two AGC settings :  
Auto Mode - Automatically adjusts the gain.  
Off Mode - In the off mode the AGC is off.  
To change the AGC mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Gain/AGC.  
5. Press the Iris Open button to enter the Gain/AGC menu.  
6. Position the cursor (>) beside AGC mode.  
7. Press the Iris Open button. The cursor moves to the right, beside the word Auto or Off.  
8. Move the joystick up or down to choose between Auto or Off.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
10  
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GAIN  
The gain adjusts the signal level of the video output. Increasing the gain in low light  
conditions will increase the level of noise in the picture.  
To change the gain:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Gain/AGC.  
5. Press the Iris Open button to enter the Gain/AGC menu.  
6. Position the cursor (>) beside Gain.  
7. Press the Iris Open button. The cursor moves to the right, beside the current gain  
setting (a numeric value).  
8. Move the joystick up or down to change the gain. As you change the gain, the picture  
on your monitor gets brighter or darker.  
9. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
LIMIT STOPS  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Limit stops  
Park time minutes  
Scan speed deg/s 25  
Exit  
On  
On  
0
<Line Sync>  
<Power Up>  
<Other>  
EXIT  
There are two types of limit stops:  
Manual limit stops - A manual (joystick) pan operation stops when a limit stop is reached.  
Scan limit stops - The dome reverses direction during random, frame, or auto  
scanning when a limit stop is reached.  
Limit stops are controlled by software. To set limit stops:  
1. Turn on the limit stop mode.  
2. Program the limit stops.  
TURNING LIMIT STOPS ON OR OFF  
To change the limit stop mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Limit Stops.  
5. Press the Iris Open button. The cursor moves to the right, beside the word On or Off.  
6. Move the joystick up or down to toggle between On and Off.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
PROGRAMMING LIMIT STOPS  
Manual Limit Stops  
Refer to the documentation for your control system for programming presets, and then do  
the following:  
1. Make sure limit stops are turned ON, and then exit the menu.  
2. Push the joystick left until you reach the limit you want the camera to go to on the left.  
3. Program preset 90 (23).  
NOTE: Programming  
preset 90 (23) disables the  
manual limit stops until  
preset 91 (24) is set.  
4. Push the joystick right to the limit you want the camera to go to on the right.  
5. Program preset 91 (24).  
Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.  
Pelco Manual C2422M (5/00)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scan Limit Stops  
Refer to the documentation for your control system for programming presets, and then do  
the following:  
1. Make sure limit stops are turned ON, and then exit the menu.  
2. Push the joystick left until you reach the limit you want the camera to go to on the left.  
3. Program preset 92 (25).  
4. Push the joystick right to the limit you want the camera to go to on the right.  
5. Program preset 93 (26).  
NOTE: On power-up, the  
auto scan tilt angle will be  
whatever angle the camera  
was at when the right scan  
limit was set.  
Setting presets 92 (25) and 93 (26) to the same point disables scan limit stops.  
LINE SYNCHRONIZATION  
Main Menu  
Line Sync Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
Line sync  
Line sync phase  
Exit  
On  
0
EXIT  
If cameras are out of phase with each other, they may produce what appears to be vertical roll  
when switching between cameras.  
There are two settings for line synchronization:  
On - Adjust the synchronization of the power line voltage so that it is in phase with other  
cameras.  
Off - The dome synchronizes to an internal clock.  
To change the line synchronization settings:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Line Sync.  
3. Press the Iris Open button. The Line Sync menu appears.  
4. Position the cursor (>) beside one of the choices. Press the Iris Open button.  
LINE SYNC - The cursor moves to one of two choices: ON or OFF. Move the joystick up or  
down to toggle between them. Press the Iris Open button to select the choice. If you changed to  
OFF, the camera may reset itself as it adjusts to the new synchronization. If the camera resets,  
it will only affect the line synchronization. It will not change any other camera parameters, such  
as auto focus or auto iris. Press the Iris Close button if you do not want to change the setting.  
LINE SYNC PHASE - The cursor moves to a numeric value. Move the joystick up or down  
to change the value. Press the Iris Open button to select the choice. The value represents the  
phase angle in tenths of a degree between 0 degrees and 350 degrees. For example, 900 is  
90 degrees, 1200 is 120 degrees, and 2400 is 240 degrees. Press the Iris Open button on  
your keyboard to select your choice. The Line Sync setting will change to ON. The camera  
may reset or the picture on your monitor may wiggle when you change the phase angle. If the  
camera resets, it will only affect the line synchronization. It will not change any other camera  
parameters, such as auto focus or auto iris. Press the Iris Close button if you do not want to  
change the setting.  
12  
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARK TIME MINUTES  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Limit stops  
Park time minutes  
Scan speed deg/s 25  
Exit  
On  
On  
0
<Line Sync>  
<Power Up>  
<Other>  
EXIT  
This feature causes the dome to park at preset 1 after a programmed number of minutes of  
control inactivity. The time can be set from 1 minute to 720 minutes (12 hours), or it can be set  
to zero, which disables this feature.  
To change the park time:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Park Time Minutes.  
5. Press the Iris Open button. The cursor moves to the right, beside the current park time.  
6. Move the joystick up or down to change the park time.  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
NOTE: Preset 1 must be  
programmed for the dome to  
park.  
POWER-UP MODE  
Main Menu  
Power-Up Menu  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
Power Up  
Exit  
Default  
EXIT  
This feature lets the dome resume a desired condition following power-up. The menu  
includes the following choices.  
Default -  
On power-up, the dome goes through a configuration cycle and stops at  
zero reference, showing “Configuration Done,address, and mode  
settings on the screen.  
Park -  
The dome moves to preset 1 when the power-up sequence finishes.  
The only text on the screen is the preset label (if any is programmed).  
Scan Auto - The dome initiates scan mode when the power-up sequence finishes.  
Again, there is no text.  
Scan Frame - The dome initiates a frame scan when the power-up sequence finishes.  
Scan Rand - The dome initiates a random scan when the power-up sequence finishes.  
The default setting is Default.  
To select the power-up mode:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Power Up Mode.  
3. Press the Iris Open button to enter the Power Up Mode menu.  
4. Press the Iris Open button to move the cursor to the right.  
5. Move the joystick up or down to cycle through the selections. Stop on the item you  
want to select.  
6. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
Pelco Manual C2422M (5/00)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RESET CAMERA  
Main Menu  
Camera Menu  
Backlight comp  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
EXIT  
Exit  
Resetting the camera returns the settings to their defaults.  
Default Settings  
Backlight comp  
Gain/AGC  
AGC mode  
Gain  
Off  
Auto  
10  
Auto-iris  
Mode  
Level  
Shutter speed  
Auto focus mode  
Sharpness  
Auto  
180  
Auto  
Auto  
5
White balance  
Auto white bal  
White bal hue  
Auto  
26  
When the camera is reset, the following settings are not changed: park time, auto flip  
disable, and limit stops.  
Turning off power to the Spectra Lite dome does not reset the camera. Camera settings are  
retained in memory. When the power is turned back on, the settings will be the same as  
they were when the power was turned off.  
To reset the camera:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Reset Camera.  
5. Press the Iris Open button to reset the camera.  
14  
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCAN SPEED  
Main Menu  
Other Menu  
<Camera>  
Auto flip  
Limit stops  
Park time minutes  
Scan speed deg/s 25  
Exit  
On  
On  
0
<Line Sync>  
<Power Up>  
<Other>  
EXIT  
The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan  
modes: auto, random, and frame scan.  
To change the scan speed:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Other.  
3. Press the Iris Open button to enter the Other menu.  
4. Position the cursor (>) beside Scan Speed deg/s.  
5. Press the Iris Open button. The cursor moves to the right, beside the number of degrees.  
6. Move the joystick up or down to toggle through the number of degrees (1-40) until you  
reach the number you want. (If set on a low number, the scan will appear to barely  
move but is still functioning.)  
7. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
SHARPNESS  
Main Menu  
Camera Menu  
Next Menu  
Sharpness Menu  
Shutter speed  
Auto focus mode  
<Sharpness>  
<White balance>  
Prev (back to prev. menu)  
Exit  
Auto  
Auto  
Backlight comp  
Off  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Sharpness  
Exit  
5
EXIT  
Exit  
Do the following to manually adjust the sharpness of the picture:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside Sharpness.  
7. Press the Iris Open button to enter the Sharpness menu.  
8. Press the Iris Open button. The cursor moves to the right, beside the sharpness value.  
9. Move the joystick up or down to toggle through the available sharpness values. As the  
numeric value changes, the sharpness of the picture on the monitor changes.  
10. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
Pelco Manual C2422M (5/00)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SHUTTER SPEED  
Main Menu  
Camera Menu  
Next Menu  
Backlight comp  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Off  
Shutter speed  
Auto focus mode Auto  
<Sharpness>  
<White balance>  
Prev (back to prev. menu)  
Exit  
Auto  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
EXIT  
Exit  
There are several shutter speed settings:  
Auto  
1/125  
1/500  
1/1000  
1/2000  
1/4000  
1/10,000  
In the Auto setting the camera controls the shutter speed automatically. Increasing the  
shutter speed lowers the light sensitivity, but rapidly moving objects will be less blurred as  
the speed is increased.  
To change the electronic shutter speed settings:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside Shutter Speed.  
7. Press the Iris Open button.  
8. The cursor moves to the right, beside the current shutter speed.  
9. Move the joystick up or down to choose the shutter speed.  
10. SELECT - Press the Iris Open button on your keyboard to select your choice.  
CANCEL - Press the Iris Close button if you do not want to change the setting.  
16  
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WHITE BALANCE  
Main Menu  
Camera Menu  
Next Menu  
White Balance Menu  
Backlight comp  
Off  
Shutter speed  
Auto focus mode  
<Sharpness>  
<White balance>  
Prev (back to prev. menu)  
Exit  
Auto  
Auto  
<Camera>  
<Line Sync>  
<Power Up>  
<Other>  
Reset camera  
<Gain/AGC>  
<Auto-iris>  
<Next>  
Auto white bal  
White bal hue  
Exit  
Auto  
26  
EXIT  
Exit  
The settings for white balance are as follows:  
Auto  
White balance hue  
To change the white balance settings:  
1. Program preset 95 (28). The main menu appears.  
2. Position the cursor (>) beside Camera.  
3. Press the Iris Open button to enter the Camera menu.  
4. Position the cursor (>) beside Next.  
5. Press the Iris Open button to go to the Next menu.  
6. Position the cursor (>) beside White Balance.  
7. Press the Iris Open button. The White Balance menu appears.  
8. Position the cursor (>) beside one of the following choices and press the Iris Open button.  
AUTO WHITE BALANCE - The cursor moves to one of two choices: Auto or Off.  
Move the joystick up or down to toggle between them. Press the Iris Open button to  
select the choice, or press the Iris Close button if you do not want to change the setting.  
WHITE BALANCE HUE - Adjust the color by moving the joystick up or down to a  
value between 1 (blue end of the spectrum) and 99 (red end). Hold the joystick up or  
down to fast forward or fast reverse through the values. As you change the value, you  
can see the color change on your monitor. Press the Iris Open button to select the  
value, or press the Iris Close button if you do not want to change the setting. If Auto  
White Balance is on, it changes to off when you select a new value.  
Pelco Manual C2422M (5/00)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
DOME CLEANING  
Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch the  
surfaces of the dome.  
Exterior Surface - Clean the dome’s exterior surface with a nonabrasive cleaning cloth and  
cleaning agent that is safe for acrylic. Either liquid or spray cleaner/wax suitable for fine  
furniture is acceptable.  
Interior Surface (Except Chrome or Gold) - Clean the same as the exterior surface.  
Interior Surface (Chrome or Gold) - The inside surface of a chrome or gold dome is easily  
scratched. Use the following precautions to maintain the dome’s surface.  
1. Always handle the dome from the outside of its circular flange.  
2. Never touch the coated inside surface. The acid in your fingerprints will eventually etch  
the coating if the fingerprints are not carefully removed according to the recommended  
cleaning procedure in item 5.  
3. If dust or other contaminants accumulate on the dome’s interior, remove the debris with  
compressed air. Compressed air cans are available from photographic equipment or  
electronic supply dealers.  
4. If heavy residue accumulates and cannot be removed with air pressure, rinse with water  
and immediately dry with air pressure so that water spots will not remain. Avoid wiping  
the coated surface with direct hand pressure - it will easily abrade unless extreme care  
is taken. Once scratched, the dome cannot be recoated.  
5. If internal wiping is necessary, avoid hand rubbing. Instead, make a wick as follows:  
Use a very soft paper towel. Roll a section into a tightly wound tube. Tear the tube in  
half, and wet the fuzzy end of the wick with a solution of isopropyl alcohol diluted with  
water. Hold the dome with its opening facing downward and wipe the interior of the  
dome with the wet end of the wick. Use a circular motion, starting from the outside and  
spiraling into the center. Use a new wick for each two passes over the dome.  
SERVICE MANUAL  
If you need to service your unit, obtain a service manual in one of the following ways:  
Contact Pelco’s Literature Department and request service manual C1455SM-B.  
18  
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
MECHANICAL  
Pan Movement:  
360° continuous pan rotation  
Vertical Tilt:  
Unobstructed +2° to -92°  
Manual Pan/Tilt Speeds*  
Pan:  
Tilt:  
0.5°-80°/sec manual operation, 150°/sec turbo  
0.5°-40°/sec  
Preset Speeds  
Pan:  
250°/sec  
Tilt:  
200°/sec  
* For variable-speed operation an appropriate controller is required. With fixed-speed  
controllers, pan/tilt speed is 24°/sec. The CM6700 controller with the KBD200 keyboard  
has programmable fixed speeds.  
CAMERA  
Signal Format:  
NTSC (model DD5TAC)  
PAL (model DD5TAC-X)  
2:1 interlace  
Scanning System:  
Image Sensor:  
Effective Pixels  
NTSC:  
1/4-inch interline transfer CCD  
510 (H) x 492 (V)  
500 (H) x 582 (V)  
PAL:  
Horizontal Resolution  
NTSC:  
PAL:  
380 TV lines  
370 TV lines  
Lens  
Minimum f-stop:  
Focal Length:  
Zoom Ratio:  
Digital Slow Shutter:  
Horizontal  
F1.6  
3.9 mm to 63 mm optical  
16 optical zoom  
Auto/manual speed selection  
Angle of View:  
MTBF:  
Focus:  
44° (at 3.9 mm wide zoom), 3° (at 63 mm telephoto zoom)  
>1 million cycles at room temperature (zoom, focus, irs)  
Automatic and manual override  
Sensitivity:  
Sync System:  
White Balance:  
Shutter Speed  
NTSC:  
1 lux at f1.6 at signal level of 40 IRE, gain high (AGC on)  
AC line lock, phase adjustable via remote control*  
Automatic with manual override*  
Automatic (electronic iris)/manual  
1/60-1/10,000*  
PAL:  
1/50-1/10,000*  
Iris Control:  
Gain Control:  
Video Output  
NTSC:  
Automatic with manual override*  
Automatic with manual override*  
.714V ± .07V (100 IRE ± 10 IRE)  
PAL:  
.7V ± .07V  
Signal to Noise Ratio:  
>46 dB  
* Manual control of camera setup functions can be done with CM6700, CM8500, CM9500,  
CM9760 and MPT9500 controllers, but not with CM7500, MPT9000 or KBD9000 controllers.  
(Design and product specifications subject to change without notice.)  
Pelco Manual C2422M (5/00)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
If  
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
1. Model and serial number  
Exceptions to this warranty are as noted below:  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product  
when returned.  
Three years on Camclosure® and fixed camera models, except the CC3701H-2,  
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,  
which have a five-year warranty.  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series  
fixed dome products.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned  
for credit, and RA number if returned for repair).  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA  
number and freight should be prepaid. Ship to the appropriate address below.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are  
instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelcos liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product  
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for  
such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused,  
whether by the negligence of Pelco or otherwise.  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
REVISION HISTORY  
Manual # Date  
C2422M 5/00  
Comments  
Original version.  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura and ExSite are trademarks of Pelco.  
© Copyright 2000, Pelco.  
All rights reserved. U.S. Patent No. 5,931,432.  
20  
Pelco Manual C2422M (5/00)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Paxar Printer 1140 Series User Manual
Peavey Stereo Amplifier 112 User Manual
Peerless Industries TV Mount PP730 User Manual
Philips Bottle Warmer SCF663 07 User Manual
Philips Charcoal Grill 25 28PT4103 User Manual
Philips Headphones SWS2000 00 User Manual
Philips Speaker System FWD876 User Manual
Planar Car Video System PE150 User Manual
Poulan Snow Blower 416804 User Manual
Pride Mobility Battery Charger SilverStar User Manual