PT506-24DT
Pan/Tilt
Lens Control
PT506-24A
Auto/Random
Scan Control
Installation/
Operation Manual
C580M Rev D (9/97)
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
LIST OF ILLUSTRATIONS
Figure
Page
1
2
3
4
5
PT506-24DT Basic System Configuration .........................................3
PT506-24DT Configured with PT506-24A .........................................4
PT506-24DT Configured with a Relay Box ........................................4
Connector Assembly ..........................................................................5
PT506-24DT Schematics (Sheet 1 of 5) ............................................9
PT506-24DT Schematics (Sheet 2 of 5) ...........................................10
PT506-24DT Schematics (Sheet 3 of 5) ........................................... 11
PT506-24DT Schematics (Sheet 4 of 5) ...........................................12
PT506-24DT Schematics (Sheet 5 of 5) ...........................................13
PT506/PT506-24A Dimension Drawing ............................................15
6
LIST OF TABLES
Table
Page
PT506-24A Duty Cycle Combinations ...............................................7
A
Pelco Manual C580M Rev D (9/97)
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
(This page intentionally left blank.)
iv
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
1.0 GENERAL
1.1 IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be
observed.
1. Installation and servicing should only be done by Qualified Service Personnel
and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 or
6P enclosure, it is designed for Indoor use only and it must not be installed
where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resis-
tance measurement between line and exposed parts to verify the exposed
parts have not been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this
unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C580M Rev D (9/97)
1
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 DESCRIPTION
The PT506-24DT is a pan/tilt and lens control designed to remotely operate 24 VAC
pan/tilts and all Pelco motorized zoom lenses. This unit can control up to six (6)
different locations, all of which can be selected by pressing the corresponding illu-
minated push-button switch. The pan/tilt movement is controlled by an eight posi-
tion joystick. The lens functions and speed are controlled by three momentary paddle
switches and a rotary knob.
The PT506-24A provides the auto/random scan control to the PT506-24DT. Ran-
dom Scan is a significant advance in CCTV security/surveillance protection that
makes continuous duty auto scan operation virtually obsolete. Random Scan is
an effective deterrent to would-be intruders because it follows no predictable pat-
tern. The scan direction varies randomly as does the scanning time and dwell
time (4-60 seconds). Random scan makes it impossible for intruders to “beat the
system” because it has none.
Random Scan is not only a powerful weapon to protect your premises, but it also
increases your equipment life by over 100% while decreasing maintenance costs.
Its shorter duty cycle reduces gear train and drive motor wear, cable fatigue, and
motor temperature rise. Random Scan also offers you the flexibility of continuous
auto scan option with a time delay that automatically returns operations to Random
Scan after 30 minutes in continuous auto scan.
2.1 MODELS
PT506-24DT
Multiple position desk top joystick control, 120 VAC operation,
for up to 6 pan/tilts (24 VAC) and zoom lenses. For use with
PT270-24P,PT280-24P,PT280-24SL,PT180-24P,PT180-24SL,
PT175-24P, PT570-24P, PT680-24P, and PT680-24SL.
PT506-24DT/220 Same as PT506-24DT except 230 VAC operation. (CE)
PT506-24A
2.2 OPTIONS
RB24
Desk top auto/random scan control; interfaces with PT506-24DT.
Relay box for 24 VAC Pan/tilts. Extends operating distance
(control to relay box) up to 14,500 ft (4,419 m) utilizing 16 Awg.
RB115
Relay box for 120 VAC pan/tilts. Allows control to be used with
120 VAC pan/tilts and extends operating distance (one re-
quired for each pan/tilt).
2
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
3.0 INSTALLATION
Figure 1 shows a typical rear panel installation of the PT506-24DT controller. The
distance from the controller is limited by the wire size and pan/tilt used. (See Sec-
tion 3.1 Recommended Cable Distances.)
Figure 2 shows a typical rear panel installation of the PT506-24Ato the PT506-24DT.
Figure 3 shows a typical system using a relay box to extend the pan/tilt control
range and operate a 120 VAC pan/tilt.
3.1 RECOMMENDED CABLE DISTANCES
The following typical values are based on the conditions as follows:
Single common conductor for the lens
Single common conductor for the pan/tilt
Maximum rated load
10% voltage reduction from line loss
Simultaneous pan/tilt activation (2 amp current draw)
Wire Size
Pan/Tilt
Lens Functions
22 Awg
20 Awg
18 Awg
16 Awg
40 ft (10 m)
60 ft (18 m)
95 ft (30 m)
150 ft (45 m)
620 ft (182 m)
1,000 ft (294 m)
2,300 ft (676 m)
3,600 ft (1,058 m)
Figure 1. PT506-24DT Basic System Configuration
Pelco Manual C580M Rev D (9/97)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2. PT506-24DT Configured with PT506-24A
Figure 3. PT506-24DT Configured with a Relay Box
4
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 CONNECTOR ASSEMBLY
Assemble the connector parts according to the instructions below. Detail B, below,
reflects the pin arrangement specific to all PT506-24DT Pan/Tilt and Lens Control
and the PT506-24AAuto/Random Scan Control. Refer to Figure 4 during assembly.
For best results use an AMP style crimper when making the wire to pin connection.
The instructions that follow apply to all AMP style connectors regardless of pin size
or pin number.
1. Slide the connector clamp assembly over the conductor cable. If the diameter
of the conductor cable is such that the rubber boot will slide over it easily then
slide the rubber boot onto the conductor cable at this time. If not, discard the
rubber boot.
2. Prepare the wires from the conductor cable as follows:
a. Strip at least 1" from the cable jacket to expose the wires. You may need
to strip more from the cable jacket if you have more wires.
b. Strip 1/8" from each wire.
c. Using an AMP style crimper, crimp the wires and their insulation to the
connector pins. Refer to Detail A in Figure 4.
3. Slide the connector pins into the appropriate holes in the connector body until
they snap into place. Refer to Figure 4 for correct pin arrangement, depending
on model and options.
4. Push the connector clamp assembly (with boot, if used) toward the connector
body. Screw the clamp assembly onto the connector body, being careful not to
disturb the wires.
5. To complete the assembly, attach the appropriate clamp with the screws pro-
vided and tighten.
1/8"
1"
FRONT VIEW
14-PIN
OR
3
1
7
4
8
11
14
12
Figure 4. Connector Assembly
Pelco Manual C580M Rev D (9/97)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 OPERATION
The PT506-24DT will not allow control of any of the six pan/tilt stations until one is
selected by pressing the desired station on the latching selection switches. Once a
selection has been made, the switch will illuminate and all control functions will be
available only to that particular station. It is considered that all pan/tilt and lens
control functions are self-explanatory. Refer to Section 4.1, OPERATIONALTEST–
PT506-24DT, for details of each control function.
The PT506-24A will allow each pan/tilt station to have auto/random scan operation.
Each station can be put into auto/random mode by pushing the paddle switch “up”
for the corresponding station.
4.1 OPERATIONAL TEST — PT506-24DT
After installing the interconnecting cable between the pan/tilt and control, plug the
control into a 120 VAC outlet, turn the control on, and test operation using the
following procedure:
1. Select a station.
2. Move the joystick to the “UP” position; the front of the tilt table should move
upwards. Move the joystick to the “DOWN” position; the front of the tilt table
should move downwards.
3. Move the joystick to the “LEFT” position; the unit should pan to the left (clock-
wise). With the joystick at the “RIGHT” position, the unit should pan to the right
(counterclockwise).
4. Test operation of the diagonal positions of the joystick, which combine both
pan and tilt functions simultaneously. For example, moving the joystick diago-
nally to the left between “LEFT” and “UP” should pan the unit to the left and
move the tilt table up.
5. Test Zoom operations by moving the paddle switch “UP” for the TELE opera-
tion and “DOWN” for the WIDE operation.
6. Test Focus operations by moving the paddle switch “UP” for NEAR FOCUS
and “DOWN” for FAR FOCUS.
7. Test Iris operations by moving the paddle switch “UP” for IRIS OPEN and
“DOWN” for IRIS CLOSE.
8. Rotate the lens speed knob and test for fast and slow speeds of all lens func-
tions by observing their operation as the knob is adjusted.
9. Select another station and repeat steps 1 through 8.
6
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
4.2 OPERATIONAL TEST — PT506-24A
The PT506-24Awill add two modes of automatic pan operation to the PT506-24DT.
Once the PT506-24A is interconnected as shown in Figure 2, apply power to the
units. When the corresponding paddle switch to the station selected is in the down
or middle position, manual control of the pan functions can be obtained. All units
power-up in the “manual” mode. Once the switch is momentarily pressed “UP”, the
selected station goes into random scan mode. This causes scanning between lim-
its in an unpredictable pattern.
The duration of scan varies randomly between approximately 0 and 60 seconds. At
the completion of a scan period, a dwell (or rest) period occurs. This dwell period
varies randomly between about 4 seconds and an adjustable 60 to 900 seconds.
The PT506-24A is factory preset for a duty cycle of 50%. However, Random Scan
dwell time is adjustable by installation or removal of diodes CR9, 10, & 11 on
PCB1500530. Table A shows the available duty cycle combinations.
At the completion of a dwell period, another scan period is started. The direction of
this scan period is also randomly determined. When a pan limit is reached, scan
direction is reversed automatically.
Table A. PT506-24A Duty Cycle Combinations
CR 11
CR 9
CR 10
DUTY CYCLE
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
50.00%
25.00%
17.00%
12.50%
10.00%
8.00%
7.00%
6.25%
Where: 1 = Diode in circuit
0 = Diode out of circuit
CONTINUOUS AUTO SCAN
For continuous AUTO SCAN, press “AUTO/RANDOM” a second time. After approxi-
mately one half-hour in Auto Scan, the unit automatically reverts to Random Scan.
NOTE: Pressing “AUTO/RANDOM”
while in Random Scan causes a
shift to Auto Scan and starts the
half-hour timer. Similarly, pressing
“AUTO-RANDOM” while in Auto
Scan causes a shift to Random
Scan and zeros the half-hour timer.
Manual operation can be activated by moving the joystick while the unit is inAuto or
Random Scan.
Pelco Manual C580M Rev D (9/97)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
5.0 MAINTENANCE
Under normal operating conditions and usage, maintenance of this equipment is
not necessary. However, if maintenance is required, repairs should be performed
by a qualified service technician or equipment should be returned to the factory for
repair.
NOTE: Pelco offers a 24-hour, seven-day-a week Technical
Assistance Program (TAP) designed to assist any customer with a
technical problem involving Pelco equipment whether it’s the week-
end or late at night. For technical assistance dial (800) 289-9100
and you will be connected to a Pelco TAP member who is trained
to answer your questions.
Pelco also guarantees one-day turnaround on any Pelco equip-
ment sent in for repair. This includes warranty and non-warranty
items. Refer to the section on “Warranty and Return Information”
in this manual for the proper procedure.
8
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
6.0 SCHEMATICS
If necessary, refer to the following schematics for troubleshooting or repair
Figure 5. PT506-24DT Schematics (Sheet 1 of 5)
Pelco Manual C580M Rev D (9/97)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5. PT506-24DT Schematics (Sheet 2 of 5)
10
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5. PT506-24DT Schematics (Sheet 3 of 5)
Pelco Manual C580M Rev D (9/97)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5. PT506-24DT Schematics (Sheet 4 of 5)
12
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5. PT506-24DT Schematics (Sheet 5 of 5)
Pelco Manual C580M Rev D (9/97)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
7.0 SPECIFICATIONS
ELECTRICAL
PT506-24DT
Input Voltage:
Output Voltage:
120 VAC, 50/60 Hz (230 VAC optional)
24 VAC, 60 Hz pan/tilt supply
0 to ±9 VDC lens supply
Power
Requirement:
1.65 amps (190 vA)
Cable
Requirements:
11 conductors (Pan/tilt 5 + ground; Lens 4 + ground)
2 AG type 1ASB
Fuse Protection:
Power Cord:
Connectors:
3-wire grounded #18 Awg
AMP CPC type (mate supplied)
Replacement
Lamps:
Station Select Switch replacement lamp #LAP72524
PT506-24A
Power
Requirements:
1.04 amps (120 vA)
3 AG, 2 amps
Protection:
Power Cord:
CONTROLS
PT506-24DT
3-wire grounded
Pan/Tilt Selection: 6 latching, illuminated push buttons
Pan/Tilt:
8 position joystick (UP, DOWN, LEFT, RIGHT, and simulta-
neous combinations for pan/tilt when joystick is moved diago-
nally.)
Zoom:
Paddle switch, TELE/WIDE
Paddle switch, NEAR/FAR
Paddle switch, OPEN/CLOSE
Potentiometer
Focus:
Iris:
Lens Speed:
On/Off:
Rocker switch
Pilot Lamp:
PT506-24A
On/Off:
Light emitting diode
Rocker switch
Auto/Random:
6 Rocker switches (one for each pan/tilt); 2 operational posi-
tions (Auto/Random and Manual)
14
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL
Enclosure Construction
Panel:
Aluminum
Cover:
Chassis:
Steel, textured black enamel
Steel, galvanized
Temperature
Range:
32° to 120°F (0° to 50°C)
Size:
See Figure 6
Weight
PT506-24DT
PT506-24A
13 lbs 6 oz (6 kg)
18 lbs (8.1 kg)
Shipping Weight
PT506-24DT
PT506-24A
14 lbs 6 oz (6.5 kg)
19 lbs (8.5 kg)
Rating:
NEMA 1
(Design and product specifications subject to change without notice.)
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
Figure 6. PT506/PT506-24A Dimension Drawing
Pelco Manual C580M Rev D (9/97)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
8.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X,
CC3751H-2,CC3651H-2X,MC3651H-2,andMC3651H-2Xcameramodels,whichhaveafive-
year warranty.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed
dome products.
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
Sixmonthsonallpanandtilts,scannersorpresetlensesusedincontinuousmotionapplications
(that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment.
AllgoodsrequiringwarrantyrepairshallbesentfreightprepaidtoPelco,Clovis,California.Repairs
made necessary by reason of misuse, alteration, normal wear, or accident are not covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the
specific use or application made of the Products. Pelco’s liability for any claim, whether based on
breach of contract, negligence, infringement of any rights of any party or product liability, relating
totheProductsshallnotexceedthepricepaidbytheDealertoPelcoforsuchProducts. Innoevent
will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss
of profit and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
Ifawarrantyrepairisrequired, theDealermustcontactPelcoat(800) 289-9100or(559)292-1981
to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty
conditions stated above, please include a written explanation with the product when returned.
Methodofreturnshipmentshallbethesameorequaltothemethodbywhichtheitemwasreceived
by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800)
289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit,
and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number
and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed
to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
Pelco, the Pelco logo, Camclosure, Esprit,
Genex, Legacy, and Spectra are registered
trademarks of Pelco.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Endura and ExSite are trademarks of Pelco.
© Copyright 1997, Pelco. All rights reserved.
16
Pelco Manual C580M Rev D (9/97)
Download from Www.Somanuals.com. All Manuals Search And Download.
|