I N S T A L L A T I O N
ICS090 Series Camclosure®
Housing (Not Upgradeable)
®
C2477M (6/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFEGUARDS AND WARNINGS
1. Installation and servicing should be done only by qualified service personnel and conform to all
local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and must not be installed where exposed to rain and moisture.
3. Use only installation methods and materials capable of supporting four times the maximum
specified load.
C2477M (6/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
3
WELCOME
Thank you for purchasing Pelco’s ICS090 Series Camclosure® housing for indoor applications. The
unit is easy to install and can be mounted to the surface of a ceiling/wall or recessed in a ceiling/
wall.
The following is supplied with the ICS090 Series housing:
Qty. Description
1
1
2
2
2
2
Assembled ICS090 Series housing (back box and bubble)
Adapter plate
8-32 x 1.00-inch Phillips pan head screws
8-32 x .750-inch self-tapping screws
8-32 x 2.50-inch self-tapping screws
10-32 x 1.50-inch self-tapping screws
MODELS
ICS-090HNU
ICS-090BHNU
White housing with smoked dome
Black housing with smoked dome
NOTE: ICS090 Series housing models are not compatible with camera and lens packages and are
not upgradeable.
4
C2477M (6/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
REMOVE THE BUBBLE
Turn the bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a nonabrasive
surface.
Figure 1. How to Remove the Bubble
C2477M (6/03)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALL THE BACK BOX
The installation methods for the ICS090 Series housing include the following:
•
•
•
Mount to the surface of a ceiling/wall
Install in a suspended ceiling
Install in a fixed ceiling/wall
Select the best method for your installation and refer to the following pages for instructions.
INSTALLATION TO SURFACE OF A CEILING/WALL
Using 6-32 toggle bolts, attach the surface mount ring and back box to the mounting surface (refer
to Figure 2). For a concrete ceiling/wall installation, use 8-32 mounting hardware (refer to Figure 3).
WALL OR
CEILING
6-32 TOGGLE BOLTS
(NOT SUPPLIED)
BACK BOX
AND SURFACE
MOUNT RING
Figure 2. Ceiling/Wall Installation
CONCRETE WALL
OR CEILING
8-32
MOUNTING
HARDWARE
(NOT SUPPLIED)
BACK BOX
AND SURFACE
MOUNT RING
Figure 3. Concrete Ceiling/Wall Installation
6
C2477M (6/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
IN-CEILING INSTALLATION – SUSPENDED CEILING
Refer to Figure 4 for the following steps.
1. Remove the ceiling tile from the ceiling.
2. Cut a four-inch diameter hole in the ceiling tile.
3. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following:
a. Place fingers on the circular marks located on the sides of the surface mount ring.
b. Pinch the sides.
c. Lift and remove the surface mount ring from the back box. Do not discard surface mount
ring, because it is required to complete the installation.
4. Turn the surface mount ring upside down and place it on the inside of the ceiling tile.
5. Attach the back box to the ceiling tile and surface mount ring with the two 10-32 x 1.50-inch
self-tapping screws (supplied).
6. Replace the ceiling tile.
SURFACE MOUNT RING
CEILING
TILE
BACK BOX
10-32 x 1.50
SELF-TAPPING
SCREWS
(SUPPLIED)
Figure 4. Ceiling Tile Installation
STANDOFF
BACK BOX
SURFACE
MOUNT RING
Figure 5. How to Remove Surface Mount Ring from Back Box
C2477M (6/03)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
IN-CEILING INSTALLATION – FIXED CEILING/WALL
Refer to Figure 6 for the following steps.
1. Cut a four-inch diameter hole in the ceiling/wall.
2. Remove the surface mount ring from the back box. Refer to Figure 5 and do the following:
a. Place fingers on the circular marks located on the sides of the surface mount ring.
b. Pinch the sides.
c. Lift and remove the surface mount ring from the back box.
3. Using 3-16 toggle bolts, attach the back box to the mounting surface.
BACK
BOX
CEILING/
WALL
3-16 TOGGLE BOLTS
(NOT SUPPLIED)
Figure 6. In-Ceiling Installation to a Fixed Ceiling/Wall
8
C2477M (6/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
REINSTALL THE BUBBLE
To install the bubble refer to Figure 7 and do the following:
1. Align the standoffs of the bubble with the slots of the back box.
2. Turn the bubble clockwise until it locks in place.
Figure 7. How to Install the Bubble
C2477M (6/03)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
General
Construction
Back Box and
Surface Mount Ring: ABS plastic
Bubble:
Finish:
Polycarbonate
White
Environment:
Weight
Indoor
Unit:
Shipping:
.52 lb (.24 kg)
2 lb (.91 kg)
(Design and product specifications subject to change without notice.)
5.30 (13.46)
5.72 (14.53)
1.65
(4.19)
4.04
(10.26)
4.04
(10.26)
2.39
(6.07)
3.90
3.90
(9.91)
(9.91)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
10
C2477M (6/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of
shipment. Exceptions to this warranty are as noted below:
•
•
•
•
•
•
•
•
•
•
Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC3600 Series); two years on all other cameras.
Three years on Genex® Series (multiplexers, server, and keyboard) and 090 Series Camclosure® Camera System.
Two years on 100/150, 200 and 300 Series Camclosure® Camera Systems.
Two years on cameras and all standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM6800E/CM8500/CM9500/CM9740/CM9760 Matrix, DF5 and DF8 Series Fixed Dome products.
Two years on Spectra®, Esprit®, and PS20 Scanners, including when used in continuous motion applications.
Two years on Esprit and WW5700 series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders.
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products.
Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to
the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or
consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from
state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an
authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the
appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico:
Puerto Rico:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Intermediate Consignee
American Overseas Air Freight
320 Beach Road
Burlingame, CA 94010
USA
Ultimate Consignee
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
USA
® Pelco, the Pelco logo, Spectra, Genex, Legacy, Esprit, and Camclosure are registered trademarks of Pelco.
© Copyright 2003, Pelco. All rights reserved.
REVISION HISTORY
Manual #
Date
Comments
C2477M
6/03
Original version.
C2477M (6/03)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
®
World Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
ISO9001
Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada
Download from Www.Somanuals.com. All Manuals Search And Download.
|