Pelco Home Security System C1666M A 4 06 User Manual

I N S T A L L A T I O N  
TW3001AR  
Active Receiver  
Single Channel for UTP Transmission  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Instructions  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s  
instructions.  
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other  
apparatus (including amplifiers) that produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has  
two blades with one wider than the other. A grounding plug has two blades and a third  
grounding prong. The wide blade or the third prong are provided for your safety. If the provided  
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience  
receptacles, and the points where they exit from the apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold  
with the apparatus. When a cart is used, use caution when moving the cart/apparatus  
combination to avoid injury from tip-over.  
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has  
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been  
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or  
moisture, does not operate normally, or has been dropped.  
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,  
such as vases shall be placed on the apparatus.  
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or  
moisture.  
16. Installation should be done only by qualified personnel and conform to all local codes.  
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is  
designed for indoor use only and it must not be installed where exposed to rain and moisture.  
18. Use only installation methods and materials capable of supporting four times the maximum  
specified load.  
19. A CCC-approved power cord must be used to power this equipment when used in China.  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Regulatory Notices  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any  
interference received, including interference that may cause undesired operation.  
RADIO AND TELEVISION INTERFERENCE  
This equipment has been tested and found to comply with the limits of a Class A digital device,  
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used  
in accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case  
the user will be required to correct the interference at his own expense.  
Changes and Modifications not expressly approved by the manufacturer or registrant of this  
equipment can void your authority to operate this equipment under Federal Communications  
Commission’s rules.  
In order to maintain compliance with FCC regulations shielded cables must be used with this  
equipment. Operation with non-approved equipment or unshielded cables is likely to result in  
interference to radio and television reception.  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.  
The materials used in the manufacture of this document and its components are compliant to the  
requirements of Directive 2002/95/EC.  
This equipment contains electrical or electronic components that must be recycled properly to  
comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical  
and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this  
equipment.  
4
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Description  
The TW3001AR is a single-channel active receiver that can receive live video over unshielded twisted  
pair (UTP) cable.  
The adaptive technology in the TW3001AR automatically adjusts the low, medium and high frequency  
components of the video signal allowing for the best possible video transmission. The adaptive  
technology eliminates the need for manual adjustment by automatically adjusting to provide the most  
favorable video transmission depending on cable length needed. The unit has been optimized for use  
with Cat5e and Cat6 cable, although Cat3 and Cat5 cable can be used for shorter distances.  
The DIP switch on the bottom of the TW3001AR allows you to override the adaptive technology and  
manually select the cable distance. Switches 1, 2, 3, and 4 can be set to 4,000 feet (1,219 meters),  
3,000 feet (914 meters), 2,000 feet (610 meters), and 1,000 feet (305 meters), respectively. Switch 5  
can be set to high mode and low mode.  
There are two ways to power the TW3001AR. You can power it by installing it into an RK5000PS-3U  
using the 4-pin connector. For stand-alone power, you can use the 2-pin power connector and use  
either a 12 VDC power supply (supplied) or a 24 VAC power supply.  
The following features are found on the TW3001AR:  
Full motion color/black-white video up to 4,000 feet (1,219 meters) with Cat5e or Cat6  
Supports Coaxitron® control (PTZ control signals) up to 750 feet (229 meters)  
Compatible with all Pelco twisted pair equipped cameras, enclosures, and domes  
Built-in surge suppression  
Easy termination with removable UTP connector  
Supports NTSC, PAL, and SECAM  
Can be mounted into a Pelco fiber rack, wall mount base kit, or wall clip  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
PARTS OF THE RECEIVER  
MODEL  
SN  
FREQ  
W
+
-
Figure 1. TW3001AR Parts  
Rubber Feet (4): For placing unit on a flat surface, such as a desk or shelf.  
Status LED: Lights red when there is no UTP video being received. Lights green when there is  
UTP video being received. Flashes amber when Coaxitron pan/tilt/zoom (PTZ) control commands  
are being received.  
Pelco Badge: Lights blue to indicate power when using either the 4-pin rack power connector  
or the 2-pin power connector.  
Rack Power Connector: 4-pin, power from RK5000PS-3U.  
Power Connector (3.5 mm): 2-pin; stand-alone power, 12 VDC or 24 VAC.  
UTP Connector (2.5 mm): 2-pin connector with removable mating connector.  
BNC Connector: Coaxial output.  
DIP Switch: Override the adaptive technology with the manual selection of cable distance  
(1,000 to 4,000 feet or 305 to 1,219 meters). Switch 5 is used for selecting high mode or low  
mode.  
6
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Make sure all parts are present for the unit.  
1
1
1
1
Universal power supply (Part #PS04-1502-0512G)  
Wall clip  
2-pin power connector  
2-pin UTP connector  
MOUNTING  
The TW3001AR receiver is 3 rack units high and can be mounted into a fiber rack, onto a wall using  
a fiber wall mount kit or into the supplied wall clip.  
USING A RACK  
You can mount a TW3001AR into either an RK5000PS-3U (for power) or an RK5000-3U. For additional  
mounting information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis Installation  
manual.  
USING WALL MOUNT KITS  
The optional WM5001-3U wall mount base kit allows attachment of a single TW3001AR to a wall. Up  
to two WM5001-3UEXP wall mount expansion kits can be used to allow attachment of two additional  
receivers to the wall. For additional information, refer to the Fiber Wall Mount Kits Installation man-  
ual.  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
USING A WALL CLIP  
To attach the TW3001AR receiver to a wall using the supplied wall clip, refer to Figure 2 and do the  
following:  
1. Attach the wall clip to a wall using two screws (not supplied).  
2. Slide the receiver into the clip until the two holes on the bottom of the receiver align with the  
two holes on the lower flange of the clip.  
3. Attach the receiver to the clip using the two Phillips pan head screws provided with the clip.  
UPPER  
FLANGE  
VERTICAL  
MOUNTING HOLE (2)  
HORIZONTAL  
MOUNTING HOLE (2)  
TW3001AR  
LOWER  
FLANGE  
SCREW, PHILLIPS  
PAN HEAD WITH  
LOCK WASHER (2)  
WALL CLIP  
Figure 2. Mounting the TW3001AR Using the Wall Clip  
8
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SETTING THE DIP SWITCHES  
You can override the adaptive technology by manually adjusting switches 1 through 4 on the DIP  
Switch. The factory default switch positions are shown in Figure 3. Switches 1 through 4 are set to  
AUTO and Switch 5 is set to H MODE (high mode).  
Figure 3. Default Switch Positions  
If you want to transmit video over 4,000 feet (1,219 meters) of UTP cable, set switch 1 to 4K. Set  
switch 2 to 3K if you want a distance of 3,000 feet (914 meters), switch 3 to 2K if you want a distance  
of 2,000 feet (610 meters), and switch 4 to 1K if you want a distance of 1,000 feet (305 meters).  
You can set only one distance at a time.  
With switch 5 you can select H (high) or L (low). High mode is the default position and is used when  
video is 1Vp-p. Low mode is used when video is less than 1Vp-p.  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
 
APPLICATIONS  
You can connect the TW3001AR active receiver to transmitters, such as the TW3001P passive trans-  
ceiver and the TW3001AT active transmitter, and to Pelco UTP cameras, such as the CC3710/CC3610  
Series. Although you can connect these products using an unshielded twisted pair Cat3 and Cat5  
cable, Cat5e and Cat6 are recommended for the best video performance.  
Always connect the UTP wires on the Cat cable from + to + and from - to -. For example, if you connect  
the blue wire to the + on the TW3001AR make sure you connect the other end of the blue wire to the  
+ on the transmitter.  
Table A shows the maximum cable distance with Coaxitron or video only when connecting the  
TW3001AR to a TW3001P passive transceiver with a particular type of Cat cable.  
Table A. Cable Distance with TW3001P  
Maximum Distance Maximum Distance  
Cable Type  
(with Coaxitron)  
750 ft (229 m)  
750 ft (229 m)  
750 ft (229 m)  
750 ft (229 m)  
(video only)  
1,500 ft (457 m)  
3,000 ft (914 m)  
4,000 ft (1,219 m)  
4,000 ft (1,219 m)  
Cat3e  
Cat5e  
Cat5e  
Cat6e  
NOTE: Cat5e cable is recommended for the best video performance.  
Table B shows the minimum size for a single wire and stranded wire.  
Table B. Wire Gauge  
Wire Gauge (minimum size)  
24 AWG (0.25 mm2)  
24 AWG (1.0 mm2)  
Single Wire (solid)  
Stranded Wire (flexible)  
10  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Figure 4 shows a TW3001AR connected to a UTP Camclosure®.  
TW3001AR  
POWER FROM RK5000PS-3U  
OR  
12 VDC OR 24 VAC  
POWER SUPPLY  
+
-
CAMCLOSURE  
UTP  
BLUE WIRE =  
MONITOR  
GRAY WIRE =  
Figure 4. TW3001AR Connected to a UTP Camclosure  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
 
Figure 5 shows a TW3001AR connected to a UTP fixed camera.  
TW3001AR  
POWER FROM RK5000PS-3U  
OR  
12 VDC OR 24 VAC  
POWER SUPPLY  
+
-
FIXED CAMERA  
UTP  
PIN 5 +  
PIN 4 -  
MONITOR  
10 PINS  
(5-/6+)  
8 PINS (4-/5+)  
Figure 5. TW3001AR Connected to a UTP Fixed Camera  
12  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 6 shows a TW3001AR connected to a UTP Spectra® Dome for Coaxitron PTZ control.  
TW3001AR  
POWER FROM RK5000PS-3U  
OR  
12 VDC OR 24 VAC  
POWER SUPPLY  
SPECTRA  
+
-
VC-UTP BOARD  
COAXITRON  
UTP  
MONITOR  
VIDEO  
MATRIX  
Figure 6. TW3001AR Connected to a Spectra Dome  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
 
Figure 7 shows a TW3001AR connected to a TW3001P passive transceiver. The TW3001P then  
connects to a non-UTP fixed camera.  
TW3001AR  
POWER FROM RK5000PS-3U  
OR  
12 VDC OR 24 VAC  
POWER SUPPLY  
+
-
UTP  
TW3001P  
DIRECT  
CONNECTION  
FIXED  
CAMERA  
MONITOR  
Figure 7. TW3001AR Connected to a Single Passive Transceiver  
14  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 8 shows a TW3001AR connected to a TW3032P passive transceiver.  
TW3001AR  
POWER FROM RK5000PS-3U  
OR  
12 VDC OR 24 VAC  
POWER SUPPLY  
+
TW3032P  
-
UTP  
MONITOR  
Figure 8. TW3001AR Connected to a 32-Channel Passive Transceiver  
C1666M-A (4/06)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 9 shows a TW3001AR connected to a TW3004P passive transceiver. The TW3004P then  
connects to a non-UTP fixed camera.  
TW3001AR  
TW3004P  
12 VDC OR  
24 VAC  
POWER SUPPLY  
POWER FROM RK5000PS-3U  
OR  
+
-
4
3
1
UTP  
2
MONITOR  
FIXED  
CAMERA  
Figure 9. TW3001AR Connected to a 4-Channel Passive Transceiver  
16  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Specifications  
ELECTRICAL  
Input Voltage  
Power Consumption  
Wire Type  
12 VDC or 24 VAC, 50-60Hz  
2.5 W  
Unshielded twisted pair (24 AWG maximum)  
Cat3 or better  
Wire Category  
DC Loop Resistance  
Differential Capacitance  
Transient Immunity  
52 ohms per 1,000 feet  
19pF/ft max  
300 W peak pulse power (8/20 US)  
VIDEO CHARACTERISTICS  
Video Output  
Format  
Frequency Response  
1, BNC  
NTSC, PAL, SECAM  
DC to MHz  
Common Mode/Differential  
Mode Rejection  
>70 dB  
MECHANICAL  
Connectors  
BNC  
Video output  
Rack power  
UTP input/output  
Power  
4-Pin Connector  
2-Pin Connector (2.5 mm)  
2-Pin Connector (3.5 mm)  
Construction  
Finish  
Steel  
Silver  
GENERAL  
Operating Temperature  
Relative Humidity  
Data Transmission  
LED Indicators  
32° to 167°F (0° to 75°C)  
0 to 90%, noncondensing  
Supports Coaxitron up to 750 feet  
Pelco badge (blue); status LED (red, green, flashing amber)  
Dimensions  
8.75" D x 1.08" W x 4.81" H  
(22.23 x 2.74 x 12.22 cm)  
Unit Weight  
1.0 lb (0.45 kg)  
C1666M-A (4/06)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
C1666M-A (4/06)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of  
shipment.  
Exceptions to this warranty are as noted below:  
Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted pair transmission products.  
Three years on Spectra® IV products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and  
MC3651H-2X camera models, which have a five-year warranty.  
Three years on PMCL200/300/400 Series LCD monitors.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.  
Two years on Spectra III, Esprit®, ExSite, and PS20 scanners, including when used in continuous motion applications.  
Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).  
Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays. The lamp and color wheel will be covered for a period of  
90 days. The air filter is not covered under warranty.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and EnduraSeries distributed network-based video  
products.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight  
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this  
warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelcos  
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products  
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state  
to state.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and  
provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written  
explanation with the product when returned.  
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization  
number (CA number if returned for credit, and RA number if returned for repair).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate  
address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the  
following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco  
Pelco c/o Expeditors  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
REVISION HISTORY  
Manual #  
C1666M  
C1666M-A  
Date Comments  
1/06 Original version.  
4/06 Added high mode and low mode information.  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, Coaxitron, and Spectra are registered trademarks of Pelco.  
Endura and ExSite are trademarks of Pelco.  
©Copyright 2006, Pelco.  
All rights reserved.  
DLP is a registered trademark of Texas Instruments, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Worldwide Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
Australia Canada Finland France Germany Italy Macau The Netherlands Russia Singapore  
|
|
|
|
|
|
|
|
|
South Africa Spain Sweden United Arab Emirates United Kingdom United States  
|
|
|
|
|
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips Car Stereo System FWM37 User Manual
Philips Car Video System 190E2 plus User Manual
Philips Work Light P 2494 C User Manual
Pioneer Stereo Receiver VSX D908TX User Manual
Pioneer Stereo System VSX 515 K User Manual
Poulan Trimmer 545192174 User Manual
Poulan Trimmer TE450 LE User Manual
Premier Mounts Projector Accessories EST150 User Manual
ProForm Home Gym PFEL39012 User Manual
PYLE Audio DJ Equipment PWMA 840 User Manual