1.0 GENERAL
1.1 IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be
observed.
1. Installation and servicing should only be done by Qualified Service Personnel
and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or
6P enclosure, it is designed for indoor use only and it must not be installed
where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resis-
tance measurement between line and exposed parts to verify the exposed
parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four
(4) times the weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this
unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C456M-D (1/98)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
1.2 UNPACKING INSTRUCTIONS
Unpack and inspect all parts carefully.
Be sure to save the shipping carton and any inserts.They are the safest material in
which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its
carton and contact the factory at 1-800-289-9100 or 1-559-292-1981 for a replace-
ment. (International customers fax 1-559-348-1120 for authorization and instruc-
tions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY
AND RETURN section of this manual for instructions.
The following items are supplied:
BB08A120 MODEL
1
1
Back box with face plate, trim ring, and dome
Parts bag
2
4
Eye bolts with nuts, flat washers and split lock washers
T-rail clips
1
Installation/Operation Manual (C456M-D)
BB08E120 and BB08E211 MODELS
1
1
1
1
1
Bezel with dome
Pendant cap
Back box
Parts bag with two O-rings (BB08E211 only)
Installation/Operation Manual (C456M-D)
1.3 RECOMMENDED TOOLS
Pelco does not supply basic tools needed for the installation process.The following
tools are recommended:
Medium Phillips screwdriver
Wire cutter
Wire stripper
BNC crimp tool
Coaxial cable stripper
Hammer and punch (suspended ceiling model only)
Large Phillips screwdriver (suspended ceiling model only)
11 mm wrench (suspended ceiling model only)
4
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 DESCRIPTION
The BB08 Series of back boxes is part of the IDS08 Intercept® Series of domes.
The IDS08 Series is an integral system that includes a back box (BB08), dome
drive (DD08), dome receiver/driver (DRD08), and imager/optics package (IOP08).
This manual covers the BB08 Series of back boxes. For installation and operation
instructions for the dome drive, refer to manual C416M-C; for the dome receiver/
driver, refer to C466M-E; and for the imager/optics package, refer to C1441M-C.
2.1 MODELS
BB08A120
Indoor back box with smoked dome; 24 VAC input; installs in a
suspended ceiling. (CE, UL)
BB08E120
BB08E211
Indoor black pendant-mount back box with smoked dome.
24 VAC input.
Outdoor light gray pendant-mount back box with clear dome.
120 VAC input. Includes heater and fan. (UL)
Pelco Manual C456M-D (1/98)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
3.0 INSTALLATION
3.1 SUSPENDED CEILING
1. Remove the ceiling tile from the ceiling. If you are installing the back box into a
2' x 4' (61 x 122 cm) ceiling grid, cut the tile in half and install an additional “T”
bar for support. Reinstall one of the 2' x 2' (61 x 61 cm) sections.
2. Bring the wiring to the back box opening in the ceiling.
•
•
Video - Refer to Table A for the type of video coaxial cable to use.
Power - If the input power to the dome is 24 VAC, refer to Table B to
determine the size of wire to use. The power requirement is 48 vA.
•
Control - If you are using a Coaxitron® controller, the control signals to
operate the dome drive will be transmitted over the video coax.
If you are not using a Coaxitron® controller, bring wires to the back box
for two RS-485 control lines (RX+ and RX-).
6
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table A. Video Coaxial Cable Requirements
Cable Type*
Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
* Minimum cable requirements:
75 ohms
All-copper center conductor
All-copper braided shield with 95% braid coverage
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC applications
and are calculated with a 10-percent voltage drop.(10-percent is generally the maxi-
mum allowable voltage drop for AC-powered devices.)
Wire Gauge
EXAMPLE: An enclosure that re-
quires 80 vA and is installed 35 feet
(10 m) from the transformer would
require a minimum wire gauge of 20
Awg.
20
18
16
14
12
10
10
20
30
283 451 716 1142 1811 2880
(86) (137) (218) (348) (551) (877)
141 225 358
571 905 1440
(42) (68) (109) (174) (275) (438)
94 150 238 380 603 960
(28) (45) (72) (115) (183) (292)
NOTE: Distances are calculated in
feet; values in parentheses are
meters.
40
50
60
70
112 179
(21) (34) (54)
285 452 720
(86) (137) (219)
56 90 143
(17) (27) (43)
47 75 119
(14) (22) (36)
40 64 102
(12) (19) (31)
35 56 89
(10) (17) (27)
228 362 576
(69) (110) (175)
190 301 480
(57) (91) (146)
70
80
90
163 258 411
(49) (78) (125)
142 226 360
(43) (68) (109)
31
(9)
50
79
126 201 320
(38) (61) (97)
(15) (24)
100 28
(8)
45 71
(13) (21)
41 65
(12) (19)
37 59
(11) (17)
34 55
(10) (16)
32 51
(9) (15)
30 47
(9) (14)
28 44
(8) (13)
26 42
(7) (12)
25 39
(7) (11)
23 37
(7) (11)
22 35
(6) (10)
114 181 288
(34) (55) (87)
110 25
(7)
103 164 261
(31) (49) (79)
120 23
(7)
95
150 240
(28) (45) (73)
130 21
(6)
87 139 221
(26) (42) (67)
81 129 205
(24) (39) (62)
76 120 192
(23) (36) (58)
71 113 180
(21) (34) (54)
67 106 169
(20) (32) (51)
63 100 160
(19) (30) (48)
60 95 151
(18) (28) (46)
57 90 144
(17) (27) (43)
140 20
(6)
150 18
(5)
160 17
(5)
170 16
(4)
180 15
(4)
190 14
(4)
200 14
(4)
Pelco Manual C456M-D (1/98)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
3. To create an opening for the wiring, use a hammer and punch to remove one
of the knockouts in the top of the back box. If it is necessary to work inside the
back box, remove the trim ring and dome by inserting a screwdriver or your
fingers between the trim ring and the faceplate and popping the trim ring and
dome loose.
4. Remove the trim ring and dome (see step 3). Remove the parts bag inside the
back box. Reattach the trim ring and dome to the back box.
5. Angle the back box through the grid opening and set the back box into the
grid.
6. From an opening in a grid adjacent to the back box, install the four T-rail clips
that are supplied in the parts bag (refer to Figure 1).
7. If additional support is required (such as anchoring with a chain or steel cable
to a support beam above the dome enclosure), install one or both of the 1/4-
20 eye bolts and washers that are supplied in the parts bag:
a. Remove one or two of the 1/4-20 screws in the top of the back box.
b. Screw a nut about a half inch onto an eyebolt.
c. Slide a split lock washer and flat washer onto the eyebolt.
d. Screw the eyebolt into the back box and lock the eyebolt into place by
tightening the nut with an 11 mm wrench.
e. Repeat steps b-d if you are going to install the second eyebolt.
f.
Use a chain or cable to fasten the eyebolt(s) to a support structure in the
ceiling.
8. Remove the trim ring and dome.
Refer to Figure 2 for the following steps.
9. Push the wiring into the back box. If you are using conduit, fasten the conduit
to the back box.
10. Install the coaxial cable to the BNC connector.
11. Install power to the 10-position terminal block. Make sure the power switch on
the side of the back box is off.
Figure 1. “T-Bar” Clip Installation
8
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 2. 24 VAC Back Box Wiring Diagram
Pelco Manual C456M-D (1/98)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 3. 120 VAC Back Box Wiring Diagram
10
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
12. If you are not using Coaxitron® control, connect the control wiring to RXD+
and RXD-.
From controller
To 4-wire terminal inside back box
TXD+
TXD-
RXD+
RXD-
13. Back box installation is now complete.Proceed with the installation of the dome
drive unit. Refer to the manual provided with the dome drive for further instal-
lation instructions.
3.2 PENDANT
1. Install the pendant dome mount. Refer to the instructions supplied with the
mount.
NOTE:The length of pipe may cause
noticeable motion on the video dis-
play. If this occurs, additional support
of the pipe by bracing, guy wiring, etc.
will be required.
2. The back box is designed to be suspended from a suitable length of 1-1/2"
NPT pipe threaded at both ends. For outdoor model, apply pipe thread sealant
to the pipe before assembly. Install one end of the pipe into the mount.Tighten
to approximately 30 ft/lb and tighten any locking means that may be provided
on the mount.
3. Bring the wiring for the back box through the mount.
•
•
Video - Refer to Table A for the type of video coaxial cable to use.
Power - If the input power to the dome is 24 VAC, refer to Table B to
determine the size of wire to use. For the 120 VAC model, make sure the
wiring can supply power for the heaters and fan as well as the receiver/
driver. Refer to Section 5.0, SPECIFICATIONS, for power requirements.
•
Control - If you are using a Coaxitron® controller, the control signals to
operate the dome drive will be transmitted over the video coax.
If you are not using a Coaxitron® controller, bring wires to the back box
for two RS-485 control lines (RX+ and RX-).
4. Remove the parts bag inside the back box.
5. Outdoor Model Only - Place an O-ring onto the back box mounting pipe.
Push the O-ring up about 4 inches (10 cm) or as far as it will go if the pipe is
not 4 inches long.
6. Outdoor Model Only - Install the pendant cap on the pipe and place the top
side of the cap against the O-ring. Place the second O-ring onto the pipe and
push the O-ring against the bottom side of the pendant cap.
7. Back out the lock screw on the mounting flange of the back box so that the
back box can be screwed onto the mounting pipe.
8. Indoor Model Only - Place the pendant cap on top of the back box.
9. Screw the back box onto the mounting pipe. Tighten the lock screw.
10. Outdoor Model Only - Push the pendant cap down against the top of the
back box. Push the top O-ring against the top of the pendant cap.
Refer to Figure 3 for the following steps.
11. Install the coaxial cable to the BNC connector.
12. Install power to the 10-position terminal block. Make sure the power switch on
the side of the back box is off.
Pelco Manual C456M-D (1/98)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
13. If you are not using Coaxitron® control, connect the control wiring to RXD+
and RXD-.
From controller
To 4-wire terminal inside back box
TXD+
TXD-
RXD+
RXD-
14. The bezel and dome assembly can be attached to the back box at this time, or
it can be done after the dome drive is installed.
To install the dome drive, refer to the manual provided with the dome drive.
To attach the bezel and dome assembly to the back box, clip the safety cable
inside the bezel to the bracket just below the power switch inside the back box.
Let the bezel and dome assembly hang from the back box until the dome drive
is installed.
15. The back box installation is now complete. Proceed with the installation of the
dome drive unit. Refer to the manual provided with the dome drive for further
installation instructions.
12
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 EXPLODED ASSEMBLY DIAGRAMS
A
B
E
F
C
D
4
2
3
6
5
7
8
1
Figure 4. BB08A120 Back Box Exploded Assembly Diagram
Pelco Manual C456M-D (1/98)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 5. BB08E120 and BB08E211 Back Boxes Exploded Assembly Diagram
14
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table C. BB08A120 Back Box Exploded Assembly Parts List (Figure 4)
Item
1
Quantity
Description
Part Number
1
1
1
1
1
1
1
4
4
1
Trim ring, white
8082ASSY
Dome seal (not shown)
Fixed dome, smoked (not shown)
Sound quieting ring (not shown)
Back box
80810007
80810008-4
8083001
2
3
4
5
6
7
8
8084297COMP
8084167COMP
8004130COMP
90010030
Face plate, drop ceiling, white
Gland plate
Ball stud receiver
T-rail retaining clip
80010008
Back box foam insert
Back box foam insert
Rocker switch, On/Off (not shown)
8083000-1
8083000
1
SWI0201S11N41P
A
B
C
D
E
F
4
4
8
8
2
2
Screw, 1/4-20 x 3/8", pan head, Phillips
Split lock washer, 1/4"
Nut, 6-32
ZH1/420X.375SPP
ZH1/4LWSSL
ZH6-32NUTSH
ZH6LWSIS
Internal star washer, #6
Eye bolt, 1/4-20 x 2"
Nut, 1/4-20
ZH1/4-20X2.0EYE
ZH1/4-20NUTCH
Table D. BB08E120 and BB08E211 Back Boxes Exploded Assembly Parts List (Figure 5)
Item
Quantity
Description
Part Number
1
2
3
1
1
1
Black bezel assembly with smoked dome
Light gray bezel assembly with clear dome
Back box, textured black
Back box, light gray
SQP0810000ASSY
SQP0810011ASSY
8084195BCOMP
8084195GCOMP
8084994COMP
8084894COMP
8004053COMP
SPA3109
Pendant cap, black
Pendant cap, light gray
Pin, bezel attachment
4
5
3
3
3
1
1
2
1
1
Nylon spacer, flanged
6
Compression spring
SPRG10000
7
Flange, 1-1/2" NPT
MRCA4000COMP
80010198
8
Gasket (BB08E211 only)
O-ring (BB08E211 only)
Safety cable
9
80010010
10
11
E7081002COMP
SWI0201S11N41P
Rocker switch, On/Off (not shown)
A
B
4
3
Screw 1/4-20 x 5/8" flat head, Phillips
Allen screw 6-32 x 1/4"
ZH1/420X.625SFS
ZH6-32X.250SS
Pelco Manual C456M-D (1/98)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 6. Back Plate Exploded Assembly Diagram
16
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table E. Back Plate Exploded Assembly Parts List
Item
Quantity
Description
Part Number
1
2
2
2
2
1
1
2
1
2
1
1
3
1
1
2
2
2
1
6
1
1
1
1
1
1
1
1
Latch backup plate
8004244COMP
8004105COMP
8004143COMP
TRF21243.30.70F
CON10P025Z41T
ZH208211-4
Latch
3
Latch bracket
4
Transformer (120 VAC model only)
25-position connector plug
Screw, 6-32
5
6
7
10-position terminal block
Alignment pin
TRB6TBV-10-OE
8004402COMP
8004118COMP
EH4600115W3
HTR50120
8
9
Heater/fan mounting bracket
Fan, 120 VAC
10
11
12
13
14
15
16
17
18
19
20
22
23
Heater, 120 VAC
Back plate
8004190COMP
8004046COMP
8004047COMP
80010007
Connector mounting bracket
Stabilizer bracket
Boot
Hairpin clip
ZH1/4CLIPSS
CON01J002Z41S
TRBJ6-2
Connector, BNC jack, insulated
2-position jumper
10-position terminal block cover
Thermostat (units with heaters and blower)
4-position terminal block
Fuse holder
TRBTC6-10-PFH
EH5510049A
TRB4-140
FUS357001
Fuse, 2A 3AG (not shown)
Capacitor, .47 µF, 12 V (not shown)
Capacitor, 220 µF, 100 V (not shown)
Capacitor, 270 µF, 100 V (not shown)
FUS2
CAPE474P012MAY
CAPF221P100JRN
CAPF271P100JRN
A
B
C
D
E
F
G
I
4
4
Screw, 10-32 x 1/2" flat head, Phillips
Split lock washer, 1/4"
ZH10-32X.500CFS
ZH1/4LWSSL
4
Nut, 1/4-20
ZH1/4-20NUTCH
SPA8540
10
2
Spacer .312 OD x 1/8" long, #10
Internal star washer, #10
ZH10LWSIS
2
Screw, 10-32 x 1" pan head, Phillips
Nut, 6-32
ZH10-32X1.00SPP
ZH6-32NUTSH
ZH6-32X.375SPP
ZH6-32X2.00SPS
SPA9401L
2
2
Screw, 6-32 x 3/8" pan head, Phillips
Screw, 6-32 x 2" pan head, Phillips
Spacer, 3/16" hex by 3/4" long, 2-56 tapped
Screw, 10-32 x 1/2" pan head, Phillips
Spacer, 1/4" hex by 1/2" long, 6-32 tapped
Screw, 6-32 x 5/8" flat head, Phillips
Screw, 6-32 x 1/2" pan head, Phillips
J
4
K
L
6
4
ZH10-32X.500SPP
SPA8423
M
N
O
2
2
ZH6-32X.625SFS
ZH6-32X.500SPP
4
Pelco Manual C456M-D (1/98)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
5.0 SPECIFICATIONS
ELECTRICAL
Enclosure Back Box
Input Voltage:
24 VAC or 120 VAC
Power Requirements
Receiver/Driver:
48 vA for 24 VAC and 120 VAC dome drives
Blower
(continuous duty): One (1) at 33 cfm, 6.7 watts, 120 VAC @ 60 Hz
Heaters
120 VAC:
135 watts total
Thermostatically controlled; activates ON at 40°F (4.4°C) and
OFF at 60°F (15.56°C)
Power Cord:
Power Cable:
GENERAL
Not supplied; use 3-wire grounded, 18 Awg minimum for 120
VAC supply input
Not supplied; must conform to local and national electrical
codes
Enclosure
Environment:
Indoor or outdoor (depending on model ordered)
See Figures 7 and 8
Dimensions:
Construction
Back box:
Cap:
Aluminum
Aluminum
Bezel:
Aluminum
Trim Ring:
ABS/aluminum
Finish
Outdoor:
BB08E211
BB08A120
Light gray
Indoor:
White (back box) and eggshell white (face
plate, trim ring and bezel)
BB08E120
Black
Temperature
Indoor Models: 32° to 120°F (0° to 48.89°C)
Outdoor Models: -10° to 120°F (-23.33° to 48.89°C)
(Design and product specifications subject to change without notice.)
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
18
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
Figure 7. BB08A120 Dimension Drawings
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
Figure 8. BB08E120 and BB08E211 Dimension Drawing
Pelco Manual C456M-D (1/98)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
6.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X,
CC3751H-2,CC3651H-2X,MC3651H-2,andMC3651H-2Xcameramodels,whichhaveafive-
year warranty.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed
dome products.
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
Sixmonthsonallpanandtilts,scannersorpresetlensesusedincontinuousmotionapplications
(that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment.
AllgoodsrequiringwarrantyrepairshallbesentfreightprepaidtoPelco,Clovis,California.Repairs
made necessary by reason of misuse, alteration, normal wear, or accident are not covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the
specific use or application made of the Products. Pelco’s liability for any claim, whether based on
breach of contract, negligence, infringement of any rights of any party or product liability, relating
totheProductsshallnotexceedthepricepaidbytheDealertoPelcoforsuchProducts. Innoevent
will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss
of profit and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
Ifawarrantyrepairisrequired, theDealermustcontactPelcoat(800) 289-9100or(559)292-1981
to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty
conditions stated above, please include a written explanation with the product when returned.
Methodofreturnshipmentshallbethesameorequaltothemethodbywhichtheitemwasreceived
by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800)
289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit,
and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number
and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed
to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
Pelco, the Pelco logo, Camclosure, Esprit,
Genex, Legacy, and Spectra are registered
trademarks of Pelco.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Endura and ExSite are trademarks of Pelco.
© Copyright 1998, Pelco. All rights reserved.
20
Pelco Manual C456M-D (1/98)
Download from Www.Somanuals.com. All Manuals Search And Download.
|