Pelco Fan C916M User Manual

®
AUX2000  
Auxiliary Control  
Box  
Installation/  
Operation Manual  
C916M (11/90)  
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150  
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION/OPERATION MANUAL  
AUX2000 AUXILIARY CONTROL BOX  
FOR THE COAXITRON® AND  
WIRETRON RECEIVER/DRIVER  
1.0 WARNINGS  
Prior to installation and use of this product, the follow-  
ing WARNINGS should be observed.  
4. Only use replacement parts recommended by  
Pelco.  
1. Installation and servicing should only be done by  
Qualified Service Personnel and conform to all Lo-  
cal codes.  
5. After replacement/repair of this unit’s electrical  
components, conduct a resistance measurement  
between line and exposed parts to verify the ex-  
posed parts have not been connected to line cir-  
cuitry.  
2. Unless the unit is specifically marked as a NEMA  
Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is de-  
signed for Indoor use only and it must not be in-  
stalled where exposed to rain and moisture.  
6. The installation methods and materials should be  
capable of supporting four (4) times the weight of  
the AUX2000.  
3. The product may bear the following marks:  
This symbol indicates that dangerous voltage  
constituting a risk of electric shock is present  
within this unit.  
This symbol indicates that there are important  
operating and maintenance instructions in the  
literature accompanying this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
CAUTION:  
TOREDUCETHERISKOFELECTRICAL  
SHOCK, DO NOT REMOVE COVER. NO  
USER-SERVICEABLE PARTS INSIDE.  
REFER SERVICING TO QUALIFIED  
SERVICE PERSONNEL.  
Please thoroughly familiarize yourself with the information in this manual  
prior to installation and operation.  
Pelco Manual C916M (11/90)  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.0 SCOPE  
3.2 RECOMMENDED CONTROLS  
CX9024RX  
Coaxitron® receiver in weatherproof  
The information contained within this manual covers  
the installation and operation of the AUX2000.  
box for 24 VAC pan/tilts, zoom lens,  
24 VAC camera power, and four ac-  
cessory functions.  
3.0 DESCRIPTION  
The AUX2000 is an auxiliary control box for the  
Coaxitron® and Wiretron receiver/drivers. It enables the  
logic level AUX 1-3 signals from the Coaxitron® and  
Wiretron receiver/drivers to control devices such as  
motors for motor operated gates, lights for parking ar-  
eas, or power relays for high power requirements.  
CX9024RX-12V SameasCX9024RXexceptsupplied  
with 12 VDC camera power.  
CX9024RXI  
Coaxitron® receiver. Same as  
CX9024RX, except for indoor use.  
CX9024RXI-12V Same as CX9024RXI except sup-  
plied with 12 VDC camera power.  
3.1 MODEL NUMBERS  
AUX2000  
Auxiliary control box for the  
Coaxitron® and Wiretron receiver/  
drivers.  
CX9115RX  
Coaxitron® receiver in weatherproof  
box for 120 VAC pan/tilt, zoom lens,  
120 VAC camera power, and four  
accessory functions.  
CX9115RXI  
CX9224RX  
CX9224RXI  
Same as CX9115RX except for in-  
door use.  
Same as CX9024RX except with 24  
VAC power input.  
Same as CX9224RX except for in-  
door use.  
CX9224RXI-12V Same as CX9224RXI except with 12  
VDC camera power.  
WX8024RX  
Wiretron receiver in weatherproof  
box for 24 VAC pan/tilts, zoom lens,  
24 VAC camera power, and four ac-  
cessory functions.  
WX8024RXI  
WX8224RXI  
WX8115RX  
Same as WX8024RX except for in-  
door use.  
Same as WX8024RXI except with  
24 VAC power input.  
Wiretron receiver in weatherproof  
box for 120 VAC pan/tilts, zoom  
lens, 120 VAC camera power, and  
four accessory functions.  
2
Pelco Manual C916M (11/90)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.0 INSTALLATION  
Refer to the following instructions when installing the  
AUX2000 auxiliary control box for the Coaxitron® and  
Wiretron receiver/drivers.  
1. Determine the location for the AUX2000 auxiliary  
control box for the Coaxitron® or Wiretron receiver/  
drivers. To determine the mounting location, con-  
sider the distance between the AUX2000 auxiliary  
control box for the Coaxitron® and Wiretron receiver/  
drivers and auxiliary functions used. Attention  
should be given to the wire distance table shown  
above.  
2. Using the AUX2000 auxiliary control box for the  
Coaxitron® and Wiretron receiver/drivers box as a  
template, mount the box to the desired location  
using the fasteners (not supplied) which will sup-  
port the full load of the unit.  
3. Assemble the mating connector as described in  
Section 4.1.  
4. Connect the auxiliary device as shown in Figure 1.  
5. Plug the AUX2000 into a 120 VAC source.  
1
2
3
P/T COMMON  
MANUAL IRIS  
LEFT  
5
DOWN  
6
UP  
7
RIGHT  
8
GROUND  
FEED THROUGH TO ENCLOSURE  
9
CAMERA AC (HIGH)  
IRIS  
FOCUS  
ZOOM  
LENS COMMON  
CAMERA AC (LOW)  
10  
11  
12  
13  
14  
OUTPUT TO A LAMP  
15  
16  
18  
AUX 1  
AUX 2  
AC HI  
OUTPUT TO A MOTOR  
RELAY OUTPUT  
1
2
4
3
17  
19  
AUX 3  
AC NEUTRAL  
OUTPUT CIRCUITS ARE RATED FOR 120 VAC,  
1 AMP, (120 VA) MAXIMUM EACH  
Figure 1. Typical Output Circuits  
Pelco Manual C916M (11/90)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.1 MATING CONNECTOR ASSEMBLY  
4. The contact pins supplied with the mating connec-  
tor are the “crimp” type which may also be sol-  
dered if you so desired (item 4).  
Installation and/or testing will require you to assemble  
the connector parts provided. Fabricate the intercon-  
necting cable according to the following steps (refer-  
ence Figure 2).  
5. After crimping or soldering the contact pins to the  
conductors, push them into the proper holes in the  
connector until they snap in place.  
1. Slide partAof the cable clamp (item 1) over the end  
of the cable (item 1, part C) with the threaded end  
of the cable clamp facing the connector (item 5).  
NOTE: Contacts cannot be removed from the  
connector without the use of the appropriate  
AMP extraction tool which is available from  
Pelco.  
2. If the cable has a diameter less than 1/2 inch (1.3 cm),  
slide the rubber boot (item 2) over the end of the  
cable and pull through the cable clamp to so that the  
boot encases the cable and forms a good seal.  
6. Slide partAof the cable clamp toward the connec-  
tor and screw the parts together.Attach part B (item  
1) onto part A and connect both parts with the  
screws provided.  
3. Strip back the cable jacket approximately 1-1/4  
inches (3.2 cm) and separate the individual con-  
ductors (item 3).  
7. Connect the cable assembly to the unit and seat  
the connector by twisting the locking collar until it  
snaps into position.  
5
1
threaded end of  
cable clamp  
A
B
C
STEP 1  
FLEXIBLE RUBBER BOOT  
5
1
A
B
STEP 2  
C
2
5 **  
3
1
4
A
B
STRIP 1/8"  
C
STEPS 3-7  
CRIMP  
INSULATION  
CRIMP  
WIRE  
OUTSIDE  
JACKET  
OF CABLE  
STRIP 1"  
4
1
5
2
1
1
**  
3
8
9
ITEM 5 DETAIL  
4
6
15  
10  
16  
23  
3
9
14  
22  
28  
10  
15  
21  
20  
25  
28  
7
33  
14  
11  
29  
37  
34  
26  
16  
15  
FRONT VIEW  
FRONT VIEW  
FRONT VIEW  
37-PIN CONNECTOR  
28-PIN CONNECTOR  
16-PIN CONNECTOR  
3
1
3
1
4
7
4
6
THE MOST COMMONLY USED  
CONNECTOR PIN-OUT CONFIG-  
URATIONS ARE SHOWN HERE.  
REFERENCE THE CONNECTOR  
DRAWING APPLICABLE TO  
YOUR SITUATION.  
11  
8
9
7
14  
12  
FRONT VIEW  
9-PIN CONNECTOR  
FRONT VIEW  
14-PIN CONNECTOR  
Figure 2. Mating Connector Assembly Diagram  
4
Pelco Manual C916M (11/90)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.0 OPERATION  
The AUX2000 is operated by the Coaxitron® or  
Wiretron controller.  
5.1 SYSTEM TEST  
Using the systems controller, verify that the auxiliary  
devices function.  
6.0 TROUBLESHOOTING GUIDELINES  
In the event that the auxiliary equipment do not work,  
retrace the wiring and verify correctness and check the  
fuse to make sure it did not open.  
Correct all errors in wiring and replace the fuse if  
opened.  
Retry to operate the auxiliary equipment.  
If the auxiliary equipment does still not operate, call  
Pelco’s Technical Assistance Program (TAP) line at  
1-800-289-9100. The TAP Line is available 24 hours  
a day, seven days a week.  
Pelco Manual C916M (11/90)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
7.0 AUX2000 MECHANICAL PARTS LIST  
Description  
Part Number  
DS100JA4000COMP  
Enclosure  
Fuse holder  
Terminal Strip  
Strain Relief  
Mating Connector (Sockets)  
Mating Connector (Pins)  
FUS357001  
TRS20007  
EH5510043  
CONA37S  
CONA37P  
8.0 ELECTRICAL PARTS LIST  
Schematic ID  
Description  
Part Number  
CON206151-1  
CON1  
Connector, 37 pins  
CON2-CON3  
CON4-CON5  
CON6  
Connector, 6 position  
Connector, 2 position  
Connector, 37 sockets  
Fuse, 3 AMP, 3AG  
CON640428-6  
CON640428-2  
CON206306-1  
FUS3  
F1  
L1-L3  
Plug 1  
RY1-RY3  
Choke, 6.2 Microhenery’s  
Cord, 18 AWG, SJT  
Relay, 120VAC, SPST  
CHO4610  
WIRC1318006BL  
REL120A01MP  
6
Pelco Manual C916M (11/90)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9.0 SCHEMATICS  
Figure 3. AUX2000 Schematics  
Pelco Manual C916M (11/90)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
10.0 SPECIFICATIONS  
MECHANICAL  
Enclosure:  
ULlistedgrayindustrialcontrolpanel  
enclosure  
Weatherproofing: Cover and connectors fully gasketed  
Mounting Means: 6 - 0.31" (.79 cm) diameter holes  
Dimensions:  
Unit Weight:  
11.31" H x 9.44" W x 4.32" D  
(28.7 cm x 4.25 cm x 10.97 cm)  
7 lbs (3.15 kg)  
Shipping Weight: 9 lbs (36.45 kg)  
ELECTRICAL  
Input Voltage: 120 VAC  
Power  
Requirements: 360 VA  
Power Cord:  
18/3 AWG, listed SJT  
Fuse Protection: 3 amp  
Connectors:  
AMP CPC type  
Conductor  
Requirements: Minimum 20 AWG  
Cable Distance:  
Wire  
Maximum Distance Maximum Distance  
Gauge  
In Feet (meters) *  
In Feet (meters) **  
1,490 (454.2)  
940 (286.5)  
16  
18  
20  
495 (150.9)  
310 (94.5)  
195 (59.4)  
590 (179.8)  
* One amp load for each auxiliary function and one  
common neutral.  
** One amp for each auxiliary function and one neutral  
conductor for each auxiliary function.  
8
Pelco Manual C916M (11/90)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Pelco Manual C916M (11/90)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
11.0 WARRANTY AND RETURN  
INFORMATION  
WARRANTY  
RETURNS  
Pelco will repair or replace, without charge, any merchandise proved  
defectiveinmaterialorworkmanshipforaperiodofoneyearafterthedate  
of shipment.  
In order to expedite parts returned to the factory for repair or credit, please  
call the factory at (800) 289-9100 or (559) 292-1981 to obtain an  
authorization number (CA number if returned for credit, and RA number  
if returned for repair).  
Exceptions to this warranty are as noted below:  
All merchandise returned for credit may be subject to a 20% restocking  
and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the  
assigned CA or RA number and freight should be prepaid. Ship to the  
appropriate address below.  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and  
keyboard).  
Three years on Camclosure® and fixed camera models, except the  
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,  
and MC3651H-2X camera models, which have a five-year warranty.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto  
Rico, send goods to:  
Service Department  
Pelco  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and  
DF5/DF8 Series fixed dome products.  
3500 Pelco Way  
Clovis, CA 93612-5699  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto  
Rico and are instructed to return goods to the USA, you may do one of the  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, includ-  
ing when used in continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding  
wiper blades).  
following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Eighteen months on DX Series digital video recorders, NVR300  
Series network video recorders, and EnduraSeries distributed  
network-based video products.  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
One year (except video heads) on video cassette recorders (VCRs).  
Video heads will be covered for a period of six months.  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods  
to:  
Six months on all pan and tilts, scanners or preset lenses used in  
continuousmotionapplications(thatis,presetscan,tourandautoscan  
modes).  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
Pelco will warrant all replacement parts and repairs for 90 days from the  
date of Pelco shipment. All goods requiring warranty repair shall be sent  
freight prepaid to Pelco, Clovis, California. Repairs made necessary by  
reason of misuse, alteration, normal wear, or accident are not covered  
under this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or  
loss resulting from the specific use or application made of the Products.  
Pelco’s liability for any claim, whether based on breach of contract,  
negligence, infringement of any rights of any party or product liability,  
relating to the Products shall not exceed the price paid by the Dealer to  
Pelco for such Products. In no event will Pelco be liable for any special,  
incidental or consequential damages (including loss of use, loss of profit  
and claims of third parties) however caused, whether by the negligence  
of Pelco or otherwise.  
The above warranty provides the Dealer with specific legal rights. The  
Dealer may also have additional rights, which are subject to variation from  
state to state.  
Ifawarrantyrepairisrequired,theDealermustcontactPelcoat(800) 289-  
9100 or (559) 292-1981 to obtain a Repair Authorization number (RA),  
and provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice  
number  
3. Details of the defect or problem  
If there is a dispute regarding the warranty of a product which does not fall  
under the warranty conditions stated above, please include a written  
explanation with the product when returned.  
Method of return shipment shall be the same or equal to the method by  
which the item was received by Pelco.  
Pelco, the Pelco logo, Camclosure, Esprit,  
Genex, Legacy, and Spectra are registered  
trademarks of Pelco.  
Endura and ExSite are trademarks of Pelco.  
© Copyright 1990, Pelco. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Stereo Amplifier ICS 4200 User Manual
Peavey Stereo Amplifier PA 6A User Manual
Philips Battery Charger SCB2100NB User Manual
Philips Cell Phone 26PFL5322 User Manual
Philips Cell Phone CTX503WHT 00 User Manual
Philips Electric Shaver 6701X User Manual
Poulan Snow Blower 421028 User Manual
Poulan Trimmer 115248826 User Manual
Poulan Trimmer 952711931 User Manual
Praktica Digital Camera DC Slim4 User Manual