O P E R A T I O N / P R O G R A M M I N G
™
ExSite Explosionproof
EHXM Series
Fixed Mount System
®
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
How to Operate Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
KBD200A/KBD300A (Direct Mode Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Quick Start Guide – System Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Language . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Unit Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Auto Focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Zoom Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Zoom Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
AGC Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Other . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Edit Detection Areas (23X Day/Night Camera) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
C1301M (6/05)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Washer Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Clear. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Software/Language File Upload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Upload Icon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-TV Interference Problems.”
This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to
operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
C1301M (6/05)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Welcome
Thank you for purchasing Pelco’s ExSite™ EHXM Series explosionproof system. Your new system features a high resolution camera/optics
package with programmable software.
This manual is designed to be a reference tool for the operation and programming of your system. Inside you will find information about the
features and commands of your EHXM system, as well as a detailed menu tree.
MODELS
EHXM30C22-2
EHXM30C22-2X
EHXM31C22-2
EHXM31C22-2X
Fixed IOP system with color camera, 60 Hz, 24 VAC
Fixed IOP system with color camera, 50 Hz, 24 VAC
Same as EHXM30C22-2, except supplied with window wiper
Same as EHXM30C22-2X, except supplied with window wiper
EHXM30CBW23-2 Fixed IOP system with day/night camera, 60 Hz, 24 VAC
EHXM30CBW23-2X Fixed IOP system with day/night camera, 50 Hz, 24 VAC
EHXM31CBW23-2 Same as EHXM30CBW23-2, except supplied with window wiper
EHXM31CBW23-2X Same as EHXM30CBW23-2X, except supplied with window wiper
EHXM30C22-7
EHXM30C22-7X
EHXM31C22-7
EHXM31C22-7X
Fixed IOP system with color camera, 60 Hz, 90-264 VAC
Fixed IOP system with color camera, 50 Hz, 90-264 VAC
Same as EHXM30C22-7, except supplied with window wiper
Same as EHXM30C22-7X, except supplied with window wiper
EHXM30CBW23-7 Fixed IOP system with day/night camera, 60 Hz, 90-264 VAC
EHXM30CBW23-7X Fixed IOP system with day/night camera, 50 Hz, 90-264 VAC
EHXM31CBW23-7 Same as EHXM30CBW23-7, except supplied with window wiper
EHXM31CBW23-7X Same as EHXM30CBW23-7X, except supplied with window wiper
GETTING STARTED
DANGER: Do not connect the power module to a supply circuit unless all ExSite system components (enclosure, camera
module and power module) are installed.
You will need to install your system before using this manual. Refer to the installation manuals for installation instructions. Once installed
apply power to the system. The system will start a configuration sequence. When configuration is done, the following information is
displayed on the monitor:
EXSITE EHXM
Version X.XX
D Address: 1
P Address: 2
Comm 2400, N, 8, 1
CONFIGURE DONE
This information will remain on the monitor until system operation begins. Refer to the following pages to learn how to operate and
program your EHXM Series system.
6
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
How to Operate Your System
Operation
How to Control
Zoom Far
To zoom far, do the following:
1. Press the Zoom Tele button or turn the joystick clockwise until zoom stops at the 32X zoom limit.
2. Release the button or joystick for one second.
3. To continue zooming (digitally), press the button or turn the joystick clockwise again until you have the picture you
want or reach the digital zoom* limit.
Zoom Wide
Alarms
Press the Zoom Wide button or turn the joystick counterclockwise.
C1301M (6/05)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSING MAIN MENU (PRESET 95)
You can call up the main menu on your monitor by programming (setting or creating) preset 95 (preset 28 if in AD32-preset mode).
Programming preset 95 for Pelco’s controllers varies according to the type of controller you are using. Instructions for programming preset
95 are given below for various Pelco controllers.
CM6700/CM6800
1. Enter the number of the ExSite EHXM system and press the CAM key.
2. Enter 95 and hold the PRESET key for two seconds.
3. In the Edit Preset menu, arrow to SET and press the ACK key. The main menu appears.
KBD200A/KBD300A (DIRECT MODE ONLY)
1. Enter 95.
2. Hold the PRESET key (approximately five seconds) until the main menu appears on the screen.
CM9500
1. Enter the number of the ExSite EHXM system and press the CAM key. The Main menu appears.
2. Highlight SETUP in the Main menu and press the SELECT key.
3. Highlight CAM in the Setup menu and press the SELECT key.
4. Highlight PRESET in the Camera menu and press the SELECT key.
5. Enter 95 and press the F1 key. The main menu appears.
CM9700 SERIES
1. Press the ESCAPE key to open the Main menu. Select DEF. The Define Submenu appears.
2. Enter your four-digit PIN if this is your first time entering this mode.
3. Enter 95 and select PRST. The main menu appears on the monitor.
4. Select the Quit icon to return to the default menu.
KBD4000/KBD4002
1. Press the SPOT MONITOR key.
2. Enter 95, then hold the PRESET key (approximately five seconds) until the main menu appears on the screen.
MPT9500
Standard Coaxitron Mode
1. Enter 95 and press the PRESET SET key.
2. Position the asterisk in the YES row and press the F1 key. The main menu appears.
Extended Coaxitron or RS-485 Mode
1. Enter 95 and press the PRESET SET key.
2. Press the F2 key. The main menu appears.
NET300/NET350/NET4001A
1. Check the Set box.
2. Click the preset 95 button. The main menu appears.
8
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Start Guide – System Setup
PELCO EXSITE EHXM
LANGUAGE
Quick Programming Guide
Access the main menu (preset 95). Refer to
<SYSTEM INFORMATION>
<DISPLAY SETUP>
Accessing Main Menu (Preset 95) section.
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
Use the joystick to position the cursor beside
menu selection. If your controller does not have a
joystick, use the up or down key.
Presets
The following presets are reserved for special functions.
EXIT
Preset
86
Function
Press Iris Open; the submenu/cursor moves to the right.
Wiper
87
88
89
95
Washer
IR filter IN (color)
IR filter OUT (black-white)
Select main programming menu
Move the joystick up or down to view selections. If
your controller does not have a joystick, use the up
or down key.
NOTE: For American Dynamics controllers with only 32 presets, switch SW3-1
DISPLAY SETUP
PRESET LABEL
ZOOM
ADDITIONAL
FREE MEMORY
SYSTEM INFORMATION
LABEL POSITION
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
on the dome drive to the ON position. When SW3-1 is ON, preset
UNIT MODEL
[PRESET LABEL- - - ---]
[ALARM 1- - - - - - -]
Press Iris Open to make selection.
95 becomes 28
89 becomes 22
88 becomes 21
LAST RESET
CAMERA ACTIVE
FPGA VERSION
VIDEO LEVEL
<CAMERA>
<EAB>
POWER MODULE MEMORY
SOFTWARE VERSION
BIOS VERSION
ALARM MESSAGE
SAVE AND EXIT
CANCEL AND EXIT
HELP
FONT VERSION
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
Press Iris Close to cancel selection.
<PMAB>
COMM
D ADDRESS
P ADDRESS
CM9500 MODE
32 PRESETS
PROTOCOL
BACK
EXIT
XXX.XXX
LANGUAGE 1
LANGUAGE 2
LANGUAGE 3
LANGUAGE 4
LANGUAGE 5
LANGUAGE 6
LANGUAGE 7
LANGUAGE 8
LANGUAGE 9
LANGUAGE 10
<AUX>
<CLEAR>
<PASSWORD>
<ADDITIONAL>
BACK
EXIT
BACK
EXIT
BACK
EXIT
POWER UP
CAMERA
OTHER
LYNE SYNC
PRESETS
PATTERNS
WINDOW BLANKING
STYLE
ALARMS
WIPER**
AUX
AUX 1 MODE
DWELL TIME (SECS)
CLEAR
PASSWORD
TYPE OF LIGHTING
AUTO FOCUS
ZOOM LIMIT
PARK TIME (MINUTES)
PARK ACTION
POWER UP ACTION
LINE SYNC
LINE SYNC PHASE
PRESET NUMBER
PATTERN NUMBER
<PROGRAM PATTERN>
<CLEAR PATTERN>
RESUME
WIPER CONTROL
WIPER MODE
WIPER DWELL (SECS)
WIPER TIME (MIN)
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
CLEAR ALL WINDOW BLANKING
ENABLE PASSWORD
<EDIT PASSWORD>
SEQUENCE (SECS)
RESET DELAY (SECS)
BACK
EXIT
PRESET NOT DEFINED
<SET WINDOWS>
ZOOM SPEED
BACK
EXIT
BACK
EXIT
AUX 2 MODE
DWELL TIME (SECS)
BACK
EXIT
LOW LIGHT LIMIT
IR CUT FILTER*
AUTO IR LEVEL*
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>*
BACK
EXIT
BACK
EXIT
<ALARM SETTINGS>
RESTORE FACTORY DEFAULTS
<SET WASHER SEQUENCE>
BACK
EXIT
BACK
EXIT
BACK
EXIT
REFERENCE INFORMATION
PATTERN USAGE
BACK
EXIT
<ADVANCED SETTINGS>
<CLEAR PRESETS>
<CLEAR CAMERA SETTINGS>
REMAINING
BACK
EXIT
BACK
EXIT
ADVANCED SETTINGS
MOTION DETECTION*
SET WINDOWS
ALARM SETTINGS
ALARM NUMBER
SET WASHER SEQUENCE
PRESET NOT DEFINED
SHUTTER SPEED
AGC LIMIT
MOTION DETECTION ENABLED
<EDIT DETECTION AREA>
WINDOW NUMBER
EDIT THE PASSWORD
- - - - - - - - - - - - - - - - -
1234567890 OK
AUTO IRIS
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
<EDIT PRESET LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESS
SHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
ACTIVATE AUX
AUX TIME
ABCDEFGHIJ
KLMNOPQRST
UZWXYZ.,-/
abcdefghij
CANCEL
ENABLE WINDOW
REVERSE
CLEAR WINDOW
ALARM CONTACT
SPACE
BACKSPACE
BACK
EXIT
WASHER TIME (SECS)
WIPER DELAY (SECS)
AUTO RETURN
BACK
EXIT
klmnopqrst
uvwxyz*;:
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
BACK
EXIT
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
WIDE DYNAMIC RANGE*
BACK
EXIT
BACK
EXIT
EDIT DETECTION AREA*
DETECTION AREA 1
LOCATION
SENSITIVITY
DETECTION AREA 2
LOCATION
SENSITIVITY
DETECTION AREA 3
LOCATION
SENSITIVITY
DETECTION AREA 4
LOCATION
SENSITIVITY
BACK
EXIT
*Available only with the 23X day/night camera.
**Available only with wiper models.
C1301M (6/05)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
10
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Language
The language for the on-screen menus is selectable. Available languages include English, Spanish,
French, German, Italian, Portuguese, Polish, Russian, Turkish, and Czecholslovakian. The factory
default language is English.
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
To change the display language:
1. Use the joystick to position the cursor beside LANGUAGE.
2. Press Iris Open. The cursor moves to the right, beside the current, selected language.
RESET CAMERA
CYCLE CAMERA POWER
3. Move the joystick up or down to view selections. Press Iris Open to enter selection.
All on-screen menus are changed to the selected language.
EXIT
Quick Programming Guide
(See Page 9)
C1301M (6/05)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
System Information
The System Information screen displays ExSite model, software version, available memory, and
other diagnostic information.
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
System settings cannot be changed using this screen. This screen is for reference only.
Use the following steps to display the System Information screen:
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
1. Use the joystick to position the cursor beside SYSTEM INFORMATION.
2. Press Iris Open. The SYSTEM INFORMATION window opens.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
SYSTEM INFORMATION
UNIT MODEL
EHXM30C22
AVAILABLE
0.90.9013
8.00.9000
1.00
POWER MODULE MEMORY
SOFTWARE VERSION
BIOS VERSION
FONT VERSION
COMM
2400,N,8,1
D ADDRESS
P ADDRESS
CM9500 MODE
32 PRESETS
PROTOCOL
1
2
OFF
OFF
D
<ADDITIONAL>
BACK
EXIT
ADDITIONAL
FREE MEMORY
LAST RESET
CAMERA ACTIVE
FPGA VERSION
VIDEO LEVEL
CAMERA
30464
3
YES
2
HIGH
XXXX-XXXX
<EAB>*
<PMAB>**
LANGUAGE 1
LANGUAGE 2
LANGUAGE 3
LANGUAGE 4
LANGUAGE 5
LANGUAGE 6
LANGUAGE 7
LANGUAGE 8
LANGUAGE 9
LANGUAGE 10
ENGLISH 1.00
ESPANOL 1.00
ITALIANO 1.00
DEUTSCH 1.00
PORTUGUES 1.00
FRANCAIS 1.00
CESKY 1.00
POLSKI 1.00
RUSSIAN 1.00
TURKISH 1.00
BACK
EXIT
**EAB (Enclosure Accessory Board) – The EAB information screen displays availability, version, and part
number of the enclosure accessory board
**PMAB (Power Module Accessory Board) – The EAB information screen displays availability, version,
and part number of the power module accessory board.
12
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Display Setup
Display setup allows you to program how labels are displayed on the monitor. The following labels
are available:
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
PRESET LABEL
ZOOM
ALARM MESSAGE Displays activated alarm.
Identifies preset.
Identifies the amount of magnification.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
A preset label is displayed when a preset is called. The zoom ratio label is displayed when zoom is
activated. An alarm message appears on the monitor when an alarm occurs.
The following settings are available for each label:
EXIT
OFF
Label is not displayed when activated.
CONSTANT
2 SECONDS
5 SECONDS
10 SECONDS
The label is continually displayed when activated.
The label is displayed for 2 seconds after activation.
The label is displayed for 5 seconds after activation.
The label is displayed for 10 seconds after activation.
DISPLAY SETUP
PRESET LABEL
ZOOM
2 (SECS)
2 (SECS)
2 (SECS)
ALARM MESSAGE
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
BACK
EXIT
Quick Programming Guide
(See Page 9)
C1301M (6/05)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
LABEL POSITIONS
Labels can be placed anywhere on the monitor. This feature allows you to customize the appearance
of your monitor screen.
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
The following labels are not set at fixed positions:
<SYSTEM INFORMATION>
<DISPLAY SETUP>
Preset Label
Alarm 1
Zoom
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
To set a label position:
EXIT
1. Use the joystick to position the cursor beside a label.
2. Press Iris Open.
3. Use the joystick to move the label up, down, left, and/or right.
4. Press Iris Open.
5. Repeat steps 1 through 4 to position other labels.
6. Position the cursor next to Save and Exit. Press Iris Open to save settings and exit menu.
DISPLAY SETUP
PRESET LABEL
ZOOM
2 (SECS)
2 (SECS)
2 (SECS)
ALARM MESSAGE
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
BACK
EXIT
[PRESET LABEL ------------]
[ALARM 1 ------------]
SAVE AND EXIT
CANCEL AND EXIT
HELP
XXX.X
14
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Unit Settings
CAMERA
TYPE OF LIGHTING
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
Pelco has calibrated settings that optimize the white balance, and the picture, for indoor and
outdoor lighting conditions. There are two settings:
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
OUTDOOR (default)
INDOOR
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
AUTO FOCUS
EXIT
Auto focus allows the lens to remain in focus during zoom-in and zoom-out functions.
There are two auto focus settings:
UNIT SETTINGS
ON (default)
If auto focus mode is set to ON, the camera will focus
automatically when using zoom functions.
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
OFF
Focus is operated manually. To focus, press the Focus Far or Focus
Near button on the controller.
ZOOM LIMIT
<AUX>
<CLEAR>
<PASSWORD>
Zoom limit allows the user to define a limitation on the amount of telephoto zoom. The following are
the zoom limit settings for the ExSite Series systems:
BACK
EXIT
23X Day/Night Camera
Camera zooms optically to 23X and then zooms electronically. 23X,
32X, 92X,184X, or 230X. Default setting is 184X.
22X Color Camera
Camera zooms optically to 22X and then zooms electronically. 32X,
88X, 176X, 220X, or 264X. The default setting is 176X.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
OUTDOOR
ON
ZOOM SPEED
ZOOM LIMIT
X184
ZOOM SPEED
MEDIUM
2
AUTO
DUSK
Zoom speed allows the user to define how fast the dome will go from full wide zoom to the
optical zoom. The default setting is MEDIUM.
LOW LIGHT LIMIT
IR CUT FILTER*
AUTO IR LEVEL*
SPEED
HIGH
MEDIUM (default)
LOW
22X COLOR
2.4 seconds
3.9 seconds
6.3 seconds
23X DAY/NIGHT
2.9 seconds
4.2 seconds
5.8 seconds
<ADVANCED SETTINGS>
BACK
*Available only with the 23X day/night camera.
NOTE: When using the HIGH setting, the image may be out of focus until zooming stops.
LOW LIGHT LIMIT
Low light limit is the maximum duration, in fractions of a second, that the electronic shutter will
remain open in low light conditions. The default setting is 2.
Settings include the following:
2 = 1/2 second
4 = 1/4 second
8 = 1/8 second
15 = 1/15 second
30 = 1/30 second
60 = 1/60 second
Quick Programming Guide
(See Page 9)
C1301M (6/05)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
IR CUT FILTER (23X DAY/NIGHT CAMERA)
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
ExSite EHXM has two modes of operation: color, and black-white. You can increase sensitivity in
low light conditions by switching to black-white mode (removing the IR cut filter). Color mode is
preferred in normal lighting conditions.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
The following are the settings for the IR cut filter:
OFF
Manual operation is controlled by preset 88 (filter IN) and 89 (filter OUT).
AUTO (default) Automatic operation is controlled by the Auto IR Level setting.
EXIT
Auto IR Level
The auto IR level is the light level at which the infrared filter switches IN or OUT.
UNIT SETTINGS
Following are the available settings for the Auto IR Level:
<CAMERA>
<OTHER>
DUSK (default) Approximately 6 lux (black-white)
Approximately 13 lux (color)
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
DARK
Approximately 0.1 lux (black-white)
Approximately 2 lux (color)
NOTES:
• If backlight compensation is ON and the IR cut filter switches OUT in normal lighting
(BLC) section.
BACK
EXIT
• Low light does not mean no light. Some type of illumination is required (street light,
IR light, etc.). The camera is not sensitive to IR light when the IR cut filter is IN.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
OUTDOOR
ON
ZOOM LIMIT
X184
ZOOM SPEED
MEDIUM
2
AUTO
DUSK
LOW LIGHT LIMIT
IR CUT FILTER*
AUTO IR LEVEL*
<ADVANCED SETTINGS>
BACK
*Available only with the 23X day/night camera.
16
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED CAMERA SETTINGS
SHUTTER SPEED
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
Shutter speed is the duration of the electronic shutter. Program shutter speed to operate
automatically (Auto) or manually (Numeric Value).
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
AUTO (default)
The electronic shutter speed is set automatically by the amount of light
sensed by the camera.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
NUMERIC VALUE
The system has several numerical shutter speed settings. The higher
the number, the faster the electronic shutter.
EXIT
The slowest shutter speed setting is 2 = 1/2 second
The fastest setting is 30,000 = 1/30,000 second
Increasing the shutter speed lowers the light sensitivity and reduces the
streaking of fast moving objects.
UNIT SETTINGS
<CAMERA>
<OTHER>
NOTE: Set the shutter speed to 100 if you are using an NTSC camera in a 50 Hz environment.
This will eliminate any flicker that may occur in the picture.
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
AGC LIMIT
<AUX>
<CLEAR>
<PASSWORD>
AGC Limit allows users to adjust how the system balances AGC (automatic gain control) and
electronic shutter in low-light conditions. As scene lighting decreases, the system will automatically
adjust, adding a mixture of AGC and slow shutter according to the AGC LIMIT setting. AGC LIMIT
can be set between 0 and 40, with 40 applying maximum AGC before slow shutter. In contrast,
setting AGC LIMIT to 0 will force the system software to apply maximum slow shutter (as defined by
the LOW LIGHT LIMIT setting) before any AGC is applied. The default setting of 28 sets the AGC and
slow shutter balance to favor AGC, yielding more real-time low-light images.
BACK
EXIT
NOTE: The maximum slow shutter that the system will achieve is 1/2 second shutter (refer to the
CAMERA
Low Light Limit section).
TYPE OF LIGHTING
AUTO FOCUS
OUTDOOR
ON
ZOOM LIMIT
X184
ZOOM SPEED
MEDIUM
2
AUTO
DUSK
LOW LIGHT LIMIT
IR CUT FILTER*
AUTO IR LEVEL*
<ADVANCED SETTINGS>
BACK
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO
28
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO
91
16
AUTO SHARPNESS
SHARPNESS LEVEL
ON
26
AUTO WHITE BALANCE
R GAIN
B GAIN
ON
146
294
BACKLIGHT COMP
VIDEO LEVEL
WIDE DYNAMIC RANGE*
OFF
HIGH
OFF
Quick Programming Guide
BACK
EXIT
*Available only with the 23X day/night camera.
(See Page 9)
C1301M (6/05)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
AUTO IRIS
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
Auto iris is the lens function that automatically opens and closes the iris in response to changing
light conditions.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
Program the auto iris to operate automatically or at a user-defined level.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
OFF
Auto iris is disabled, and control is always manual.
AUTO (default) The iris is adjusted automatically to produce a constant video output as
determined by the Auto Iris Level setting.
EXIT
NOTE: If auto iris is in the auto mode, it will remain that way until the iris is manually opened or
closed. The system will return to auto mode when it is panned or tilted more than 15 degrees.
UNIT SETTINGS
Auto Iris Level
<CAMERA>
<OTHER>
Auto iris level is the numeric value the auto iris uses to maintain the brightness level of the camera.
Increase the value to brighten the scene. Decrease the level to darken the scene. This setting can be
adjusted if the video level in the auto iris mode is too bright or too dark.
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
NOTE: If backlight compensation is ON, decrease the Auto Iris Level setting.
Auto Iris Peak
Increasing the peak value will cause the auto iris circuit to react more to highlights or “peaks” in the
picture. Decreasing this value will cause it to use the average video level to adjust the iris.
BACK
EXIT
AUTO SHARPNESS
Auto sharpness enhances picture detail by increasing the aperture gain of the camera and
sharpening the edges in the picture.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
OUTDOOR
ON
There are two settings:
ZOOM LIMIT
X184
ZOOM SPEED
MEDIUM
2
AUTO
DUSK
ON (default)
OFF
The camera automatically maintains a normal sharpness mode.
LOW LIGHT LIMIT
IR CUT FILTER*
AUTO IR LEVEL*
The sharpness of the picture is set manually by programming the sharpness
level. Sharpness level settings range from 0-63.
<ADVANCED SETTINGS>
BACK
AUTO WHITE BALANCE
This feature automatically processes the viewed image to retain color balance over a color
temperature range. The default setting for auto white balance is ON.
ADVANCED SETTINGS
R GAIN
Adjusts the picture output in the red range. As you change the value, you will
see the color change on your monitor.
SHUTTER SPEED
AGC LIMIT
AUTO
28
B GAIN
Adjusts the picture output in the blue range. As you change the value, you will
see the color change on your monitor.
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO
91
16
AUTO SHARPNESS
SHARPNESS LEVEL
ON
26
AUTO WHITE BALANCE
R GAIN
B GAIN
ON
146
294
BACKLIGHT COMP
VIDEO LEVEL
WIDE DYNAMIC RANGE*
OFF
HIGH
OFF
BACK
EXIT
*Available only with the 23X day/night camera.
18
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
BACKLIGHT COMPENSATION (BLC)
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
If a bright backlight is present, the subjects in the picture may appear dark or as a silhouette.
Backlight compensation enhances objects in the center of the picture. The system uses the center of
the picture to adjust the iris. If there is a bright light source outside of this area, it will wash out to
white. The camera will adjust the iris so that the object in the sensitive area is properly exposed.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
There are two backlight compensation settings:
ON
Backlight compensation is activated.
EXIT
OFF (default) Backlight compensation is not activated.
NOTE: If backlight compensation is ON, decrease the Auto Iris setting and adjust the Auto IR Level
UNIT SETTINGS
<CAMERA>
<OTHER>
VIDEO LEVEL
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
Set the video output to one of the following:
NORMAL - 1.0 volt peak-to-peak
HIGH (default setting) - 1.2 volt peak-to-peak to compensate for losses in video cable.
WIDE DYNAMIC RANGE (23X DAY/NIGHT CAMERA)
BACK
EXIT
The wide dynamic range (WDR) setting balances the brightest and darkest sections of a scene to
produce a picture that is better balanced in lighting and provides more detail. The range from the
darkest to the brightest sections of the scene is 80X more when WDR is ON than when OFF.
Available settings are OFF and ON. The default setting is OFF. When wide dynamic range is set to
ON the frame rate is reduced from the standard 30 frames per second to 15 frames per second.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
OUTDOOR
ON
ZOOM LIMIT
X184
ZOOM SPEED
MEDIUM
2
AUTO
DUSK
LOW LIGHT LIMIT
IR CUT FILTER*
AUTO IR LEVEL*
<ADVANCED SETTINGS>
BACK
ADVANCED SETTINGS
Wide Dynamic Range ON
Wide Dynamic Range OFF
SHUTTER SPEED
AGC LIMIT
AUTO
28
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO
91
16
AUTO SHARPNESS
SHARPNESS LEVEL
ON
26
AUTO WHITE BALANCE
R GAIN
B GAIN
ON
146
294
BACKLIGHT COMP
VIDEO LEVEL
WIDE DYNAMIC RANGE*
OFF
HIGH
OFF
BACK
EXIT
Quick Programming Guide
*Available only with the 23X day/night camera.
(See Page 9)
C1301M (6/05)
19
Download from Www.Somanuals.com. All Manuals Search And Download.
OTHER
PARK TIME
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
This feature allows the system to begin a specified operation (preset or pattern) after a programmed
time of inactivity.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
Park time can be programmed from 1 minute to 720 minutes (12 hours), or set to zero, which
disables this feature. The default setting is zero.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
Park Action
EXIT
This feature will define the activity when the system parks. The following settings are available:
NONE (default) No action.
PRESET 1
The system goes to preset 1.
The system goes to preset 8.
The system runs pattern 1.
The system runs pattern 2.
The system runs pattern 3.
The system runs pattern 4.
UNIT SETTINGS
<CAMERA>
<OTHER>
PRESET 8
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
PATTERN 1
PATTERN 2
PATTERN 3
PATTERN 4
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
OTHER
PARK TIME (MINUTES)
PARK ACTION
0
NONE
BACK
EXIT
20
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER UP
POWER UP ACTION
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
This setting defines a specific activity to be performed in the event the power to the system
is cycled.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
The following settings are available:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
NONE
No action.
AUTO (default) The camera maintains its previous camera settings before the power outage.
EXIT
PRESET 1
The system to preset 1.
The system to preset 8.
The system pattern 1.
The system pattern 2.
The system pattern 3.
The system pattern 4.
PRESET 8
PATTERN 1
PATTERN 2
PATTERN 3
PATTERN 4
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
POWER UP
POWER UP ACTION
AUTO
BACK
EXIT
Quick Programming Guide
(See Page 9)
C1301M (6/05)
21
Download from Www.Somanuals.com. All Manuals Search And Download.
LINE SYNC
Line sync refers to a programmable function that allows you to synchronize all cameras within a
PELCO EXSITE EHXM
matrix system.
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
NOTE: ExSite EHXM automatically senses V-sync input. No line sync setup is required for Pelco
control systems that provide a V-sync signal.
For matrix systems that do not output V-sync, there are two settings for line synchronization:
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
ON (default)
Adjusts the phase of the line sync to synchronize input power. LINE SYNC
PHASE settings range from 0-359 degrees.
EXIT
OFF
The system synchronizes to an internal clock.
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
LINE SYNC
LINE SYNC
LINE SYNC PHASE
ON
0
BACK
22
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
PRESETS
The ExSite EHXM system has 80 programmable preset positions. Each preset can be programmed to
PELCO EXSITE EHXM
use all programmable camera settings, and motion detection.
The presets are numbered 1-32 and 35-82.
Use the following steps to program a preset.
1. Select the preset number:
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
a. Use the joystick to position the cursor beside PRESET NUMBER. Press Iris Open.
The cursor moves to the right.
EXIT
b. Move the joystick up or down to view selections. Press Iris Open to enter selection.
2. Edit the preset label:
a. Use the joystick to position the cursor beside EDIT PRESET LABEL.
b. Press Iris Open. The following appears on the monitor:
UNIT SETTINGS
<CAMERA>
<OTHER>
LABEL FOR PRESET
PRESET NUMBER ------
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
OK
CANCEL
SPACE
BACKSPACE
klmnopqrst
uvwxyz*;:
c. Use the joystick to position the cursor beside a character. Press Iris Open to enter the
BACK
EXIT
selection. To clear a character, position the cursor beside BACKSPACE, and then press
Iris Open.
d. When the label is completed, move the cursor to OK. Press Iris Open to return to the
Preset menu.
PRESETS
3. Edit the preset scene:
PRESET NUMBER
***PRESET NOT DEFINED***
1
a. Use the joystick to position the cursor beside EDIT PRESET SCENE.
b. Press Iris Open.
c. Follow the directions displayed on the monitor.
<EDIT PREST LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>*
4. Edit preset camera settings:
a. Use the joystick to position the cursor beside EDIT CAMERA SETTINGS.
b. Press Iris Open. The EDIT CAMERA SETTINGS window appears on the monitor. Refer to
camera settings.
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
REFERENCE INFORMATION
ZOOM
CUSTOM CAMERA SETTINGS
NOTES:
--
--
• There are two additional options available for the IR Cut Filter that are only available when
programming a preset. The additional settings are YES and NO. If the IR Cut Filter is set to
YES, the preset scene will be in color. If the IR Cut Filter is set to NO, the preset scene will
be in black and white.
*Available only with the 23X day/night camera.
• You can copy camera settings from one preset to another preset. To copy camera settings
do the following:
1. Use the joystick to position the cursor beside COPY CAMERA SETTINGS.
2. Press Iris Open. The cursor moves to the right.
3. Move the joystick up or down to view selections. Press Iris Open to enter selection.
Quick Programming Guide
(See Page 9)
C1301M (6/05)
23
Download from Www.Somanuals.com. All Manuals Search And Download.
ENABLE MOTION DETECTION (23X DAY/NIGHT CAMERA)
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
The following are the settings for MOTION DETECTION ENABLED:
OFF (default) Motion detection is turned off (disabled).
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
ON
Motion detection is turned on (enabled).
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
NOTE: Motion detection does not work if the shutter speed is set at less than 1/60 of a second.
EDIT DETECTION AREAS (23X DAY/NIGHT CAMERA)
EXIT
Four motion detection areas can be defined for a preset. Use the following steps to edit motion
detection areas.
UNIT SETTINGS
1. Edit detection areas 1, 2, 3, or 4:
<CAMERA>
<OTHER>
a. Use the joystick to position the cursor beside EDIT DETECTION AREAS.
b. Press Iris Open. The EDIT DETECTION AREAS programming window appears on the monitor.
c. Use the joystick to position the cursor beside LOCATION for DETECTION AREA 1, 2, 3 or 4.
d. Press Iris Open. The cursor moves to the right next to the number 0.
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
e. Move the joystick up. A blue rectangle appears in the upper left-hand corner of the screen.
f.
Use the joystick to place the blue rectangle over the desired detection area.
g. Press Iris Open to make a selection.
NOTE: Motion detection is not guaranteed to catch 100% of activity.
BACK
EXIT
MOTION DETECTION AREAS
PRESETS
PRESET NUMBER
***PRESET NOT DEFINED***
1
<EDIT PREST LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>*
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
REFERENCE INFORMATION
ZOOM
CUSTOM CAMERA SETTINGS
--
--
MOTION DETECTION*
MOTION DETECTION ENABLED
<EDIT DETECTION AREAS>
OFF
2. Set the sensitivity of the motion detection area:
EDIT DETECTION AREAS*
DETECTION AREA 1
a. Position the cursor next to SENSITIVITY for DETECTION
AREA 1, 2, 3 or 4.
b. Press Iris Open, the cursor moves to the right.
c. Use the joystick to select one of the following sensitivity
levels:
LOCATION
SENSITIVITY
0
ACTIVATE AUX
AUX TIME (SECS)
OFF
0
MEDIUM
DETECTION AREA 2
LOCATION
SENSITIVITY
0
BACK
EXIT
MEDIUM
DETECTION AREA 3
LOCATION
SENSITIVITY
0
MEDIUM
HIGH - The sensitivity level is high. Slight changes
in light level and contrast are detectable.
MEDIUM (default) - Average sensitivity.
LOW - The sensitivity level is low.
DETECTION AREA 4
LOCATION
0
SENSITIVITY
BACK
EXIT
MEDIUM
*Available only with the 23X day/night camera.
d. Press Iris Open to make selection.
*AVAILABLE ONLY WITH THE 23X
DAY/NIGHT CAMERA.
24
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
ACTIVATE AUX COMMAND (23X DAY/NIGHT CAMERA)
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
Motion detection can be programmed to trigger an auxiliary command when motion is detected.
The following are the settings for ACTIVATE AUX:
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
OFF (default) Motion detection will not trigger an AUX command.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
1
2
Triggers a command to AUX 1.
Triggers a command to AUX 2.
EXIT
AUX TIME (23X DAY/NIGHT CAMERA)
Aux time is the length of time the auxiliary will remain on after motion is detected. Available
settings for AUX TIME are 1 through 60 seconds.
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
PRESETS
PRESET NUMBER
***PRESET NOT DEFINED***
1
<EDIT PREST LABEL>
<EDIT PRESET SCENE>
<EDIT CAMERA SETTINGS>
<MOTION DETECTION>*
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
REFERENCE INFORMATION
ZOOM
CUSTOM CAMERA SETTINGS
--
--
MOTION DETECTION*
MOTION DETECTION ENABLED
<EDIT DETECTION AREAS>
OFF
ACTIVATE AUX
AUX TIME (SECS)
OFF
0
BACK
EXIT
*Available only with the 23X day/night camera.
Quick Programming Guide
(See Page 9)
C1301M (6/05)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
PATTERNS
A pattern is a memorized, repeating, series of zoom and preset functions that can be recalled with a
command from a controller or automatically by a programmed function (alarm or power-up).
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
The ExSite EHXM can handle up to four user-defined patterns. Pattern length is based upon memory
usage rather than a fixed amount of time. The complexity of a pattern will determine the amount of
storage available to program other patterns.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
To program a pattern:
1. Use the joystick to position the cursor beside PATTERN NUMBER. Press Iris Open. The cursor
moves to the right.
EXIT
2. Move the joystick up or down to view selections. Press Iris Open to enter selection.
3. Use the joystick to position the cursor beside PROGRAM PATTERN.
4. Press Iris Open. The Patterns programming window appears on the monitor.
5. Follow the directions displayed on the monitor.
UNIT SETTINGS
<CAMERA>
<OTHER>
After a pattern is programmed, the remaining storage percentage is displayed on the screen. This is
the amount of memory available to program the remaining patterns.
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
To clear a pattern:
1. Use the joystick to position the cursor beside CLEAR PATTERN.
2. Press Iris Open.
3. Follow the directions displayed on the monitor.
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
NOTES:
• When programming one or more presets within a pattern use the normal controller
commands to Call a Preset.
• Not all controllers can start all four patterns. However, any of the four patterns can be
automatically started with power-up, and alarm functions.
PATTERNS
PATTERN NUMBER
1
<PROGRAM PATTERN>
<CLEAR PATTERN>
BACK
EXIT
REFERENCE INFORMATION
PATTERN USAGE
REMAINING
0%
100%
26
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
WINDOW BLANKING
Window blanking allows a user to program up to eight, four-sided, user-defined areas that cannot be
viewed by the operator of the system. A blanked area will automatically adjust in size as the lens
zooms telephoto and wide.
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
ExSite EHXM has two style modes for window blanking, GRAY and SMEAR. If style is set to gray,
the blanked area is covered with a solid gray window. If smear is selected, images behind the
window will be noticeable but not distinguishable.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
To set a window blanking area:
1. Use the joystick to position the cursor beside WINDOW BLANKING. Press Iris Open. The
WINDOW BLANKING menu appears on the screen.
EXIT
2. Move the joystick to position the cursor beside SET WINDOWS. Press Iris Open to enter.
3. Position the cursor beside WINDOW NUMBER. Press Iris Open. The cursor moves to the right.
4. Move the joystick up or down to view selections. Press Iris Open to enter selection.
UNIT SETTINGS
<CAMERA>
<OTHER>
5. Use the joystick to position the cursor beside EDIT WINDOW LOCATION. Press Iris Open, and
then follow the instructions that appear on the screen.
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
NOTE: Use the inside corner of the window selection tool as a
guide when selecting the upper left, upper right, bottom right,
and bottom left corners of the window.
<AUX>
INSIDE CORNER
<CLEAR>
<PASSWORD>
Set windows are not visible when editing a new window location.
BACK
EXIT
When all four corners are set, the SET WINDOWS menu reappears, the blanked area is
displayed, and the ENABLE WINDOW option is set to YES.
6. The blanked area can be programmed to turn on or off at a specified zoom point. To set the
zoom point:
WINDOW BLANKING
a. Use the joystick to position the cursor beside EDIT WINDOW ZOOM, and then press
STYLE
GRAY
Iris Open.
b. Zoom in to the point where you want window blanking to turn on. Press Iris Open to set
the zoom point.
<SET WINDOWS>
BACK
EXIT
NOTES:
• Since the area is already blanked out, it may be difficult to determine when you want
window blanking to turn on. Reverse the window before setting the zoom point.
When finished reverse the window again to blank out the area.
SET WINDOWS
• Increase the size of the window if any part of the blanked area is revealed during pan, tilt,
and zoom operations.
WINDOW NUMBER
1
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
ENABLE WINDOW
REVERSE
CLEAR WINDOW
NO
BACK
EXIT
Window Blanking Disabled
Window Blanking Enabled
Quick Programming Guide
(See Page 9)
C1301M (6/05)
27
Download from Www.Somanuals.com. All Manuals Search And Download.
REVERSE
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
A blanked out area can be reversed to make it visible and the areas on both sides of it not visible.
The areas above and below the blanking area remain visible. Reversing the window a second time
will return it to its original condition.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
CLEAR WINDOW
All areas that have been set for window blanking are cleared.
EXIT
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
WINDOW BLANKING
STYLE
GRAY
<SET WINDOWS>
BACK
EXIT
SET WINDOWS
WINDOW NUMBER
1
<EDIT WINDOW LOCATION>
<EDIT WINDOW ZOOM>
ENABLE WINDOW
REVERSE
CLEAR WINDOW
NO
BACK
EXIT
28
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
ALARMS
The ExSite EHXM system has seven alarm inputs, which can be programmed as high, medium or low
priority. When an alarm is received, an input signal to the unit triggers the user-defined action (go to
preset, run pattern, etc.) programmed for the alarm.
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
There are three global alarm settings:
<UNIT SETTINGS>
RESUME
This mode lets the system resume its previous camera settings after all
alarms are cleared.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
SEQUENCE
This is the time the system will perform an alarm activity when more than one
alarm of the same priority occurs at the same time.
EXIT
RESET DELAY This is the amount of time the system considers the alarm to be active after it
has physically cleared.
Use the following steps to program alarm settings.
UNIT SETTINGS
1. Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
<CAMERA>
<OTHER>
2. Select the alarm number:
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
a. Use the joystick to position the cursor beside ALARM NUMBER.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view selections. Press Iris Open to enter selection.
3. Select the alarm priority:
a. Use the joystick to position the cursor beside ALARM PRIORITY.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. Available settings include
HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities are active
at the same time, the dome will only go to the alarms with the highest priority.
d. Press Iris Open to enter selection.
BACK
EXIT
NOTES:
ALARMS
• HIGH alarm action takes highest priority and will override manual pan, tilt, and zoom
control.
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
OFF
5
• MEDIUM/LOW alarm action will not occur if an alarm occurs during manual pan, tilt, and
zoom control.
<ALARM SETTINGS>
4. Set the alarm action:
BACK
EXIT
a. Use the joystick to position the cursor beside ALARM ACTION.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. The following are the
settings for alarm action:
NONE
No action when alarm is triggered.
PRESET
The system goes to the preset that is the same as the alarm
number. Preset 1 will go to Alarm 1.
ALARM SETTINGS
ALARM NUMBER
1
PATTERN 1
PATTERN 2
PATTERN 3
PATTERN 4
The system runs pattern 1 when alarm is triggered.
The system runs pattern 2 when alarm is triggered.
The system runs pattern 3 when alarm is triggered.
The system runs pattern 4 when alarm is triggered.
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
LOW
NONE
NO
ALARM CONTACT
OFF
BACK
EXIT
d. Press Iris Open to enter selection.
Quick Programming Guide
(See Page 9)
C1301M (6/05)
29
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Set the auxiliary to activate:
PELCO EXSITE EHXM
a. Use the joystick to position the cursor beside ACTIVATE AUX.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the following available selections.
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
NO (default)
Not activated.
1
2
An alarm action will close AUX 1.
An alarm action will close AUX 2.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
d. Press Iris Open to enter selection.
EXIT
NOTE: The AUX 1/AUX2 will stop when all the alarms assigned to it have cleared. If the AUX1/AUX
is set up as momentary, then it will be activated each time a new alarm is activated.
6. Set the alarm contact:
a. Use the joystick to position the cursor beside ALARM CONTACT.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the following available selections.
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
N/O (default) Normally open
N/C
Normally closed
d. Press Iris Open to enter selection.
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
ALARMS
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
OFF
5
<ALARM SETTINGS>
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER
1
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
LOW
NONE
NO
ALARM CONTACT
OFF
BACK
EXIT
30
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
WIPER
The following EHXM unit models feature a window wiper to clear moisture from the window of the
enclosure:
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
EHXM31C22-2
EHXM31C22-2X
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
EHXM31C22-7
EHXM31C22-7X
EHXM31CBW23-2
EHXM31CBW23-7
EHXM31CBW23-2X
EHXM31CBW23-7X
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
NOTE: The Wiper menu is only available on the above models. To check the unit model refer to the
System Information section of this manual.
EXIT
WIPER CONTROL
This feature programs the on/off control for the wiper. There are two available settings for wiper
control, AUX 1 and Preset 86. If the wiper control is programmed for AUX 1, the wiper will operate
when AUX 1 is accessed. If the wiper control is set to Preset 86, selecting preset 86 on your
controller will turn the wiper on/off.
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
WIPER MODE
<WINDOW BLANKING>
<ALARMS>
<WIPER>
Wiper mode determines how the wiper will act after the wiper control is turned on/off. There are
two modes of operation for wiper mode:
<AUX>
<CLEAR>
<PASSWORD>
MOMENTARY (default) Programs the wiper to move across the enclosure window once and
then back to its starting position.
BACK
EXIT
CONTINUOUS
Programs the wiper to operate continually after the wiper is turned
on. The wiper will continue to operate until the wiper control (AUX 1
or preset 86) is pressed again or until the programmed wiper time is
completed.
WIPER*
WIPER CONTROL
WIPER MODE
WIPER DWELL (SECS)
WIPER TIME (MINS)
AUX 1
CONTINUOUS
2
60
WIPER DWELL
<SET WASHER SEQUENCE>
The wiper can be programmed to wipe the enclosure window every 2 to 30 seconds. This setting
only works when the wiper is programmed for continuous mode. The dwell time can be programmed
from 2 to 30 seconds.
BACK
EXIT
WIPER TIME
*AVAILABLE ONLY WITH THE WIPER MODELS.
Wiper time programs how long the wiper will be on before it automatically shuts off. This setting
only works when the wiper is programmed for continuous mode. Wiper time can be programmed
from 60 to 1,440 minutes (1 to 24 hours).
NOTE: CM9700 Matrix Systems Only – For the wiper to operate in continuous mode, the AUX 1
function in the camera file must be set to latching in the CM9700-MGR. If the AUX 1 camera file is
not latching, the wiper will only operate in momentary mode, even if the system wiper is
programmed for continuous operation. Refer to the CM9700-MGR Software Guide for instructions.
Quick Programming Guide
(See Page 9)
C1301M (6/05)
31
Download from Www.Somanuals.com. All Manuals Search And Download.
SET WASHER SEQUENCE
An external washer (not supplied by Pelco) can be used to wash the window of the enclosure.
Accessing AUX 3 or selecting Preset 87 will start the washer sequence.
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
Use the following steps to program the washer sequence.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
1. Use the joystick to position the cursor beside WIPER and then press Iris Open. The wiper menu
appears on the monitor.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
2. Position the cursor beside SET WASHER SEQUENCE and then press Iris Open.
3. Edit the preset label:
EXIT
a. Use the joystick to position the cursor beside EDIT PRESET LABEL.
b. Press Iris Open. The following appears on the monitor:
LABEL FOR PRESET WASH
WASH - - - - - - - - - - - -
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
klmnopqrst
uvwxyz#&:”
OK
CANCEL
SPACE
BACKSPACE
<AUX>
<CLEAR>
<PASSWORD>
c. Use the joystick to position the cursor beside a character. Press Iris Open to enter
selection. To clear a character, position the cursor beside BACKSPACE, and then press
Iris Open.
BACK
EXIT
d. When the label is completed, move the cursor to OK. Press Iris Open to return to the Set
Washer Sequence menu.
WIPER*
4. Edit the preset scene:
WIPER CONTROL
WIPER MODE
AUX 1
CONTINUOUS
a. Use the joystick to position the cursor beside EDIT PRESET SCENE.
b. Press Iris Open.
WIPER DWELL (SECS)
WIPER TIME (MINS)
2
60
c. Follow the directions displayed on the monitor.
<SET WASHER SEQUENCE>
5. Edit preset camera settings:
a. Use the joystick to position the cursor beside EDIT CAMERA SETTINGS.
b. Press Iris Open. The EDIT CAMERA SETTINGS window appears on the monitor. Refer to
settings.
BACK
EXIT
6. Set the washer time. The washer time programs how long the wiper will be on before it
automatically shuts off. Washer time can be programmed from 4 to 60 seconds.
SET WASHER SEQUENCE
* * * PRESET NOT DEFINED * * *
7. Program the wiper delay. Wiper delay programs when the wiper will start after the washer
sequence has started. Wiper delay can be programmed from 1 to 30 seconds.
<EDIT PRESET LABEL>
<EDOT PRESET SCENE>
<EDIT CAMERA SETTINGS>
8. Program the Auto Return to ON or OFF. If the auto return is set to ON the unit will return to the
last position before the system started the washer sequence. If it is set to OFF, the system will
remain at the preset scene for the washer sequence.
WASHER TIME (SECS)
WIPER DELAY (SECS)
AUTO RETURN
4
1
ON
<CLEAR PRESET>
<CLEAR CAMERA SETTINGS>
BACK
EXIT
*Available only with the wiper models.
32
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
AUX
An auxiliary output is a programmable signal from the system that can trigger another device to
operate. An auxiliary output is programmable to trigger from an alarm or from a controller.
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
An AUX 1 command from the controller will activate the relay in the system and operate the device
that is connected to the relay. The output of AUX 1 and AUX 2 can be connected to the alarm input
of a system switch to activate automatic monitor switching and recording.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
The following are the available AUX MODE settings:
TOGGLE (default)
Changes the state of the auxiliary output every time an AUX command is
received from the controller.
EXIT
LATCHING
Must receive an AUX ON/AUX OFF command from the controller to turn
the auxiliary output on/off.
MOMENTARY
An AUX ON command from the controller turns the auxiliary output on
for the programmed DWELL TIME. The auxiliary output will
automatically turn off when the dwell time is finished.
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
AUX
AUX 1 MODE
DWELL TIME (SECS)
TOGGLE
1
AUX 2 MODE
DWELL TIME (SECS)
TOGGLE
1
BACK
EXIT
Quick Programming Guide
(See Page 9)
C1301M (6/05)
33
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEAR
Use this setting to clear user-defined settings or return the system to factory default settings.
PELCO EXSITE EHXM
The following are the available CLEAR settings:
LANGUAGE
ENGLISH
ALL PRESETS
Clears all presets. To clear a single preset, refer to the
Presets section.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
ALL PATTERNS
Clears all patterns. To clear a single pattern, refer to the
Patterns section.
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
ALL WINDOW BLANKING
Clears all blanked windows. To clear a single blanked
EXIT
RESTORE FACTORY DEFAULTS Restores all camera settings to factory default settings.
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
CLEAR
CLEAR ALL PRESETS
CLEAR ALL PATTERNS
CLEAR ALL WINDOW BLANKING
RESTORE FACTORY DEFAULTS
BACK
EXIT
34
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
PASSWORD
ExSite EHXM features password protection to prevent unauthorized changes to the system settings.
An operator can open the System Information and Display Setup Screens, but cannot access any of
the Unit Settings menus.
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
Controller/keyboard commands cannot override password-protected settings. If a keyboard is used
to set a preset or pattern, the Enter Password screen appears on the monitor. The password must be
entered before programming can continue.
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
At least one character must be entered to create a valid password.
EXIT
UNIT SETTINGS
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
PASSWORD
ENABLE PASSOWRD
<EDIT PASSWORD>
OFF
BACK
EDIT THE PASSWORD
- - - - - - - - - - - -
1234567890
ABCDEFGHIJ
KLMNOPQRST
UVWXYZ.,-/
abcdefghij
OK
CANCEL
SPACE
BACKSPACE
klmnopqrst
uvwxyz#&:”
Quick Programming Guide
(See Page 9)
C1301M (6/05)
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Reset, Cycle Power, Reboot
RESET CAMERA
PELCO EXSITE EHXM
LANGUAGE
ENGLISH
Use this function to reset all camera settings to factory default parameters.
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
CYCLE CAMERA POWER
RESET CAMERA
If the camera is not operating or if you lose camera control, cycle camera power. Cycling camera
power resets the camera but does not change any saved camera settings.
CYCLE CAMERA POWER
REBOOT SYSTEM
EXIT
REBOOT SYSTEM
Reboot the system if it is not operating or if there is no control. Rebooting the system will cycle pan
and tilt and camera power without changing programmed settings.
36
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
Software/Language File Upload
The ExSite EHXM system allows access for on-site setup, testing, and uploading of revised operating software and language files.
A Pelco field service tool is required to perform these operations. Field service tools include Pelco’s remote monitor kit (IPS-RMK),
remote data port box (IPS-RDPE-2), and remote monitor cable (IPS-CABLE).
For instructions on how to upload revised operating software and language files refer to the Installation/Operation manual supplied
with the field service tool.
NOTE: Only perform software uploads when necessary. Software uploads do not need to be performed if the system is
operating properly.
UPLOAD ICON
During a software/language file upload, an icon will appear on the monitor to indicate data is being transferred to the system (refer to
the figure below). The default setting for data transmission is 115.2 KB per second. Noisy and long-run connections will slow the
transmission rate.
Upload Icon
Quick Programming Guide
(See Page 9)
C1301M (6/05)
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Camera
Day/Night (23X) Color
NTSC, PAL
LowLight™ (22X) Color
NTSC, PAL
Signal Format
Scanning System
Image Sensor
2:1 interlace
2:1 Interlace
1/4-inch EXview HAD™ CCD
1/4-inch CCD
Effective pixels
NTSC
724 (H) x 494 (V)
724 (H) x 582 (V)
768 (H) x 494 (V)
752 (H) x 582 (V)
PAL
Horizontal Resolution
NTSC
PAL
>470 TV lines
>470 TV lines
>470 TV lines
>460 TV lines
Lens
F1.6 (F = 3.6~82.8 mm optical)
23X optical, 10X digital
2.9/4.2/5.8 seconds
F1.6 (F = 4~88 mm optical)
22X optical, 12X digital
2.4/3.9/6.3 seconds
Zoom
Zoom Speed
Horizontal Angle of view
54˚ at 3.6 mm wide zoom
47˚ at 4.0 mm wide zoom
2.5˚ at 82.8 mm telephoto zoom
2.2˚ at 88 mm telephoto zoom
Focus
Automatic with manual override
Automatic with manual override
Maximum Sensitivity at
35 IRE
NTSC
0.08 lux at 1/2 sec shutter (color)
0.3 lux at 1/60 sec shutter (B-W)
0.013 lux at 1/2 sec shutter (B-W)
0.02 lux at 1/2 sec shutter
0.02 lux at 1/1.5 sec shutter
PAL
0.08 lux at 1/1.5 sec shutter (color)
0.3 lux at 1/50 sec shutter (B-W)
0.013 lux at 1/1.5 sec shutter (B-W)
Sync System
Internal/AC line lock, phase adjustable via
remote control, V-Sync*
Internal/AC line lock, phase adjustable via remote
control, V-Sync*
White Balance
Shutter Speed
Automatic with manual override*
Automatic (electronic iris)/Manual
Automatic with manual override*
Automatic (electronic iris)/Manual
NTSC
PAL
1/2~1/30,000*
1/2~1/30,000*
1/1.5~1/30,000*
1/1.5~1/30,000*
Iris Control
Automatic Iris Control with manual override*
Automatic Iris Control with manual override*
Gain Control
Automatic/OFF*
1 Vp-p, 75 ohms
>50 dB
Automatic/OFF*
1 Vp-p, 75 ohms
>50 dB
Video Output
Video Signal to Noise
Wide Dynamic Range
80X
N/A
*Manual control of camera setup functions can be done with CM6700, CM6800, CM8500, CM9500, CM9740, CM9760, CM9770,
CM9780, KBD200A, KBD300A, and MPT9500 controllers, but not with CM7500, MPT9000 or KBD9000 controllers.
38
C1301M (6/05)
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
Exceptions to this warranty are as noted below:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
Three years on Camclosure® and fixed camera models, except the CC3701H-2,
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,
which have a five-year warranty.
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series
fixed dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual #
Date
Comments
C1301M
6/05
Original version.
Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco.
LowLight, Endura and ExSite are trademarks of Pelco.
©Copyright 2005, Pelco. All rights reserved.
EXviewHAD is a trademark of the Sony Corporation.
Download from Www.Somanuals.com. All Manuals Search And Download.
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
ISO9001
United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
|
|
|
|
|
|
|
|
Download from Www.Somanuals.com. All Manuals Search And Download.
|