Pelco Computer Drive NSM5200 User Manual

I N S T A L L A T I O N  
®
Endura  
NSM5200 Series  
Network Storage Manager  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
C3683M (3/09)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Illustrations  
List of Tables  
4
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Notices  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful  
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  
RADIO AND TELEVISION INTERFERENCE  
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits  
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may  
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in  
which case the user will be required to correct the interference at his own expense.  
Changes and modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this  
equipment under Federal Communications Commission’s rules.  
In order to maintain compliance with FCC regulations shielded cables must be used with this equipment. Operation with non-approved  
equipment or unshielded cables is likely to result in interference to radio and television reception.  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.  
Video Quality Caution  
FRAME RATE NOTICE REGARDING USER-SELECTED OPTIONS  
Pelco systems are capable of providing high quality video for both live viewing and playback. However, the systems can be used in lower quality  
modes, which can degrade picture quality, to allow for a slower rate of data transfer and to reduce the amount of video data stored. The picture  
quality can be degraded by either lowering the resolution, reducing the picture rate, or both. A picture degraded by having a reduced resolution  
may result in an image that is less clear or even indiscernible. A picture degraded by reducing the picture rate has fewer frames per second,  
which can result in images that appear to jump or move more quickly than normal during playback. Lower frame rates may result in a key event  
not being recorded by the system.  
Judgment as to the suitability of the products for users’ purposes is solely the users’ responsibility. Users shall determine the suitability of the  
products for their own intended application, picture rate and picture quality. In the event users intend to use the video for evidentiary purposes in  
a judicial proceeding or otherwise, users should consult with their attorney regarding any particular requirements for such use.  
C3683M (3/09)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Description  
The NSM5200 Series network storage manager (NSM) delivers industry leading performance and innovation for mission-critical storage needs.  
The combination of high performance, scalable hardware design and advanced software capabilities enables the NSM5200 to meet the unique  
storage needs of physical security and video surveillance applications.  
Hardware Built for Performance, Reliability, and Scalability  
The demands of real-time video and audio recording place unique strains on storage subsystems. Storage systems require the bandwidth and  
capacity to keep up with incoming video streams. They must also simultaneously manage all other common disk and RAID functions as well as  
video streams that need to be recorded and played back on a constant basis. In addition, physical security applications are almost always  
mission critical. Any downtime, degraded performance for routine maintenance, or loss of recorded footage is extremely disruptive to the  
organization's physical security mission.  
The NSM5200 has been engineered to meet these unique performance and reliability demands. Custom hardware components, to eliminate  
common performance choke points to a patented scheme for writing content to a disk drive, have been specifically designed to deliver sustained  
high throughput for recording and playback. The NSM5200 is capable of a maximum of 250 Mbps of throughput for incoming streams while  
delivering 32 simultaneous playback streams when failover is not implemented. This performance is maintained whether the system is operating  
in normal conditions, dealing with disk drive errors, or rebuilding the RAID array.  
The NSM5200 improves the total cost of ownership and energy efficiency by consolidating disparate components into a single chassis. The  
250 Mbps throughput provides double the improvement over Pelco's first generation recorder, allowing users to service far more cameras in one  
storage unit than previously possible. In addition, with the integration of a traditional network video recorder (NVR) server into the storage  
chassis, cost and energy efficiency is optimized by eliminating the need for additional servers and the associated heating, ventilation, and  
cooling costs. Finally, the use of lower power components and adaptive cooling inside the chassis manage power dissipation based on load  
requirements. Reliability is enhanced through the use of redundancy at all common failure points. A CompactFlash (CF) card is used to host the  
operating system for higher reliability than traditional hard disk drives. To mitigate any downtime resulting from CompactFlash errors, the  
database is striped across the storage array. The RAID 6 storage configuration provides double parity protection of recorded data. The hard drive  
bay is cooled through the use of high capacity, redundant fans to ensure that the drives are kept at an optimum operating temperature. Finally,  
fully redundant power supplies guard against any power supply failure.  
As with any other system, maintenance is an important and vital part of sustained operation. The NSM5200 incorporates various innovations to  
make maintenance more efficient and to allow the system to continue operating at peak performance levels. Easy access to hard disk drives and  
the CompactFlash card is available from the front panel. A unique rail system allows access to a failed fan should it need to be replaced.  
Temperature sensors throughout the chassis detect possible airflow obstruction or clogged intake filters. The use of enterprise-class SAS®  
technology provides advanced enclosure management and monitoring. Notifications of potential or actual issues are transmitted to the Endura®  
user interfaces for action. Storage capacity is scaled using DAS5200 direct attached storage (DAS) units. Utilizing the high reliability of a SAS  
backplane and connections, up to seven DAS5200s can be connected to a single NSM5200. With up to 12 TB of raw capacity in each storage  
element, each NSM5200 can reach a maximum of 96 TB of raw capacity.  
Software Built for Flexibility, Reliability, Cost Optimization  
In addition to unique strains placed on hardware components, video surveillance applications also demand innovations in software. Recording  
software must accommodate automatic failover should a catastrophic failure occur. Recording software must deal with file fragmentation  
caused by overwrite, locking of video clips, and managing metadata associated with alarms and events. Finally, recording software must deal  
with the escalating cost of storage by finding innovative ways to manage recorded content. This ensures that the user extracts the most value  
from the cost of the storage subsystem.  
The NSM5200 supports pooling of multiple recorders to provide for automatic load balancing and failover. A single storage pool can support up  
to 512 cameras. One of the NSM5200s in the pool acts as the master and manages camera assignments, health monitoring, and redistribution of  
the recording load. Should a unit fail, the given cameras are automatically redistributed to the remaining units in the storage pool. When the  
failed unit is brought back on line, the recording load is distributed again such that the load on any given recorder is balanced. This capability  
also allows users to dynamically add additional storage to a pool as their retention needs change.  
The NSM5200 incorporates an improved version of Pelco's patented EnduraStor™ storage optimization technology. EnduraStor was developed to  
manage the cost of storing high resolution, high frame rate video by leveraging the fact that the value of recorded video is typically higher  
immediately following an incident. Organizations are capable of specifying a desired delay period during which all recorded video will be kept at  
30 images per second (25 for PAL). As the age of video available on hard disk drives exceeds the delay period, it is automatically groomed to a  
lower frame rate, thus freeing up storage capacity for new video. The NSM5200 incorporates advancements in the EnduraStor algorithm, which  
gives administrators the option of classifying the priority level of alarm or event video to retain the full frame.  
The NSM5200 is built upon the proven stability and robustness of its Linux®-based operating system. It utilizes an XFS file structure and  
automated defragmentation routines to keep the database from becoming fragmented. XFS has been proven to be a more superior file format for  
6
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
the rigors of video recording applications than an NTFS file system, which is standard with Windows®-based recorders. Although XFS is superior,  
fragmentation can build up over prolonged periods of active use. To compensate, the software incorporates defragmentation routines that run in  
the background. These routines mitigate the performance degradation and the potential for corruption that result from fragmentation errors.  
The NSM5200 incorporates a number of diagnostic monitoring functions that serve vital roles in notifying operators of potential problems and  
failures. Integrated diagnostics utilize on-board LED indicators to display warnings and failures on NSM5200 and DAS5200 units and reports  
these failures to operators on Endura workstations and virtual console displays. The NSM5200 monitors and provides warning messages for  
items such as retention time issues, accumulation of software errors, network errors that result in packet loss, and changes to network link  
speeds. It also monitors and reports hardware diagnostics such as temperatures approaching established thresholds, hard disk drive failures, fan  
failures, power supply failures, or when a camera or a NSM5200 is off line. Finally, the NSM5200 can communicate to an APC Smart-UPS® series  
uninterruptible power supply to provide battery status information and initiate a graceful shutdown if the available charge falls below its  
designated threshold.  
FEATURES  
Fully Compatible with Endura  
Recording throughput up to 250 Mbps meets demanding performance requirements for real-time video, audio, and data applications  
Hardware designed to eliminate single points of failure including redundant fans, power supplies, and RAID 6 storage for optimum  
reliability  
Pooled storage management provides distributed load balancing and automatic N+N failover across a storage pool to ensure continued  
recording if catastrophic failures occur  
Built-in EnduraStor storage management increases storage efficiency by grooming video from Pelco video encoders and IP cameras based  
on age and priority  
Expandable storage capacity using Pelco's DAS5200 SAS-based direct attached storage  
Capable of up to 32 simultaneous video/audio playback streams  
Performance levels maintained in normal and RAID error conditions  
Built-in diagnostic monitoring provides preventative maintenance and SNMP monitoring  
Reduced cost of ownership and increased energy efficiency through consolidation of multiple hardware components into a fully integrated  
chassis  
C3683M (3/09)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
MODELS  
Table A. NSM5200 Model Numbers  
Model  
Storage*  
Country Code  
3 TB  
US = North America  
EU = Europe  
UK = United Kingdom  
CN - China  
AU = Australia  
AR = Argentina  
6 TB  
9 TB  
NSM5200  
12 TB  
*NOTE: Storage capacities subject to change. Contact Pelco Product Support  
for current capacity information.  
OPTIONAL ACCESSORIES  
DAS5200 Series  
Each DAS5200 Series storage expansion box adds additional storage to each NSM5200. Up to seven units can be  
connected to an NSM5200 through an external SAS connection for a maximum of 72.7 TB of available video storage.  
When connected to an NSM5200, all DAS5200 models fully support diagnostics and monitoring.  
Replacement power supply for NSM5200 and DAS5200 Series units  
NSM5200-PSU  
NSM5200-FAN  
NSM5200-FANB  
HD5200-250  
HD5200-500  
HD5200-750  
HD5200-1TB  
HD5200-2TB  
Replacement system fan (upper middle) for NSM5200 Series units  
Replacement CPU fan (rear panel) for NSM5200 Series units  
Replacement 250 GB hard drive and carrier for NSM5200 and DAS5200 Series units  
Replacement 500 GB hard drive and carrier for NSM5200 and DAS5200 Series units  
Replacement 750 GB hard drive and carrier for NSM5200 and DAS5200 Series units  
Replacement 1 TB hard drive and carrier for NSM5200 and DAS5200 Series units  
Replacement 2 TB drive and carrier for NSM5200 and DAS5200 Series units  
8
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Before You Begin  
Endura is a network system that requires a continuous amount of bandwidth to transmit true, live video; therefore, always include your network  
administrator when planning and installing Endura components.  
You will need the following items:  
Pelco-approved Endura certification  
Access to an Endura network that is  
an active, Gigabit Ethernet network that supports the full Internet Protocol suite,  
configured with at least one Endura system manager, and  
configured with at least one Endura workstation  
NOTES:  
For best results, make sure your installation meets the power, environmental, and networking guidelines described in the  
Endura Installation Guidelines and Best Practices document.  
When using one or more network switches on the Endura network, enable autonegotiation on all switches.  
These network requirements represent the minimum standard for a small Endura-capable security network. Consult the Endura Network  
Design Guide to make sure your network is properly configured. Your system might require additional hardware, software, and network  
resources.  
PARTS LIST  
Qty Description  
1
2
1
NSM5200 Series network video recorder  
Hard drive packs (6 filled hard drive carriers each)  
Accessory pack:  
5
2
Rubber feet with 8-32 x 0.375-inch, Phillips pan head screws (for desktop mounting, installed)  
Power cords either 2 US (North American), 2 European standard, 2 UK standard, 2 Australian, or 2 Argentinian  
NOTE: Units shipped to China do not include power cords.  
2
1
Front bezel keys  
Disposable wrist strap for electrostatic discharge (ESD) protection  
1
Rack mount kit (included with accessory pack):  
Chassis mounting brackets with handles and thumbscrews (installed)  
12 Screws, 10-32 x 0.25-inch, Phillips pan head (six for each bracket, installed)  
2
2
8
8
4
1
2
2
Adjustable support rail sets (each set includes one front-mounting rail and one rear-mounting rail)  
Screws, 8-32 x 0.375-inch, Phillips truss head (four for each support rail)  
Screws, 10-32 x 0.5-inch, Phillips flat head (two for each front rail, two for each rack rail spacer)  
Screws, 10-32 x 0.75-inch, Phillips pan head (two for each rear rail)  
Cable management bracket  
Screws, 6-32 x 0.25-inch, Phillips pan head  
Rack rail spacers  
14 Cage nuts, 10-32  
3
1
1
1
Product serial number labels (attached to unit)  
NSM5200 Series Network Storage Manager Installation manual  
Web Configuration manual  
Safety instructions  
C3683M (3/09)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
USER-SUPPLIED PARTS  
In addition to the standard tools and cables required for a video security installation, you will need to provide the following items:  
Qty Description  
1
1
1
1
Cat5e (or better) cable and connectors for connecting the NSM5200 to the Endura network  
Power source (110/220 VAC)  
Small flat-tip screwdriver, if mounting the unit into a rack  
Small Phillips screwdriver, if mounting the unit into a rack  
You also need to provide all network equipment, such as switches, for the Endura network.  
PACKAGE CONTENTS  
The following diagrams show the contents of the three boxes. When installing the NSM5200, refer to these diagrams.  
SHIPPING BOX  
NSM5200  
ACCESSORY PACK  
HARD DRIVE PACK  
(12 HARD DRIVES  
IN CARRIERS)  
SAFETY INSTRUCTIONS  
INSTALLATION MANUAL  
WEB CONFIGURATION MANUAL  
Figure 1. Major Package Components  
10  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ACCESSORY PACK  
SHOWN ACTUAL SIZE  
STANDARD  
POWER CORD  
2 EA.  
RACK MOUNT KIT  
PHILLIPS PAN  
HEAD SCREW,  
8-32 X 0. 375-INCH  
5 EA.  
ESD DISPOSABLE  
WRIST STRAP  
1 EA.  
FRONT BEZEL KEY  
2 EA.  
RUBBER FEET  
5 EA.  
(INSTALLED)  
(INSTALLED)  
Figure 2. Accessory Pack  
RACK MOUNT KIT  
CHASSIS MOUNTING  
REAR MOUNT  
RAIL  
FRONT MOUNT  
BRACKETS  
RAIL  
2 EA.  
2 EA.  
PHILLIPS PAN  
HEAD SCREW,  
6-32 X 0.25- INCH  
2 EA.  
PHILLIPS PAN  
HEAD SCREW,  
10-32 X 0.25- INCH  
12 EA. (INSTALLED)  
PHILLIPS TRUSS  
HEAD SCREW,  
8-32 X 0.375-INCH  
8 EA.  
PHILLIPS FLAT  
HEAD SCREW,  
10-32 X 0.5-INCH  
8 EA.  
PHILLIPS PAN  
HEAD SCREW,  
10-32 X 0.75-INCH  
4 EA.  
CAGE NUT,  
10-32  
14 EA.  
RACK RAIL  
SPACER  
2 EA.  
CABLE MANAGEMENT  
CABLE MANAGEMENT  
BRACKET  
1 EA.  
CLIP  
3 EA.  
Figure 3. Rack Mount Kit  
C3683M (3/09)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
PRODUCT SERIAL NUMBER LABEL PLACEMENT  
Product serial number labels help identify your system and its factory configuration in the event that your NSM5200 or its components require  
service.  
Three labels citing your product’s serial number are attached to the unit. One large label is attached to the right side panel of the unit. A smaller  
label is attached to the unit’s front panel on the lower-left side, behind the front bezel.  
Because rack mounting and other installation options may obscure the factory-applied labels, a third label is provided for you to attach to your  
product documentation or other product location that will not be obscured by installation.  
To use this label:  
1. Locate the small label on the front bezel of your NSM5200, attached with a yellow sticker that reads, “Extra serial number labels: remove  
prior to installation.”  
2. Remove the yellow sticker.  
3. Peel away the backing of the small label and attach it to this installation manual, other product documentation, or an unobscured product  
location.  
SN  
03  
26  
7-  
39  
-0  
02  
0
SERIAL NUMBER  
PRODUCT LABEL  
Figure 4. Product Serial Number Labels  
12  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Equipment Placement and Rack Mounting  
The NSM5200 can be placed on a flat surface, such as a desktop, or mounted in an equipment rack.  
DESKTOP INSTALLATION  
WARNING: Do not place the NSM5200 on its side; in this position, the unit is likely to fall over and may cause equipment damage or  
personal injury.  
To install the NSM5200 on a desktop:  
1. Make sure the rubber feet are installed to prevent surface damage. If not, secure each rubber foot to the bottom panel of the unit (refer to  
Figure 5). Use the five 8-32 x 0.375-inch Phillips pan head screws (supplied).  
2. Remove the two chassis brackets from the sides of the unit, if they are attached. Remove the 10-32 x 0.25-inch Phillips pan head screws  
(six per bracket). Save the brackets and screws for possible future use.  
3. Position the unit to allow for cable and power cord clearance at the rear of the unit.  
REMOVE BRACKETS  
AND SCREWS  
5200  
M
Figure 5. Installing Rubber Feet and Removing Brackets  
C3683M (3/09)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
RACK MOUNTING  
The NSM5200 mounts into an industry-standard 19-inch (48 cm) equipment rack. The NSM5200 occupies three rack units (5.25 in. or 13.3 cm) of  
vertical rack space. The hardware necessary to mount the NSM5200 into a rack is supplied with the unit.  
The rack must meet the following requirements:  
19-inch (48 cm) EIA-310-D compliant (rear column required)  
Rack column depth: 24 to 30 inches (61 to 76 cm)  
Column mounting hole provisions: 10-32 UNF-2B threaded holes or square window holes on front and rear columns  
Door systems are acceptable. Front doors must have at least 2 inches (5.1 cm) between the NSM5200 front bezel and the inside of the door.  
Rear doors may only be used on rack columns that are more than 26 inches (66 cm) deep.  
WARNINGS:  
Secure the front and rear screws to the support rails.  
Make sure the NSM5200 is level.  
Slots and openings in the cabinet provide ventilation to prevent the unit from overheating. Do not block these openings. Never place  
the unit near or over a radiator or heat register. When placing the unit in a rack, be sure to provide proper ventilation.  
Four of the six redundant fans are located in the upper-middle portion of the unit. If the unit must be pulled out to replace a fan, make  
sure that all cables connected to the unit have sufficient length to avoid being disconnected.  
To install the NSM5200 in a rack:  
NOTE: Figure 3 on page 11 identifies each piece of hardware for this procedure.  
1. If chassis mounting brackets are not attached: Attach one mounting bracket to each side of the NSM5200. Use six 10-32 x 0.25-inch Phillips  
pan head screws for each bracket. Attach the brackets so that the tapered ends are positioned toward the rear of the unit.  
ATTACH BRACKETS  
(6) SCREWS  
10-32 X 0.25-INCH  
PHILLIPS PAN HEAD  
00  
52  
M
Figure 6. Fastening Mounting Brackets to Chassis  
2. Remove the rubber feet from the underside of the unit if they are attached.  
14  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3. Attach one front-mount rail to one rear-mount rail. Make sure the rails are mounted back to back, as shown in Figure 7. Depending on rack  
depth, use either three or four 8-32 x 0.375-inch Phillips truss head screws for each rail set. Leave the screws loose until step 10.  
(4) SCREWS 8-32 X 0.375  
PHILLIPS TRUSS HEAD  
Figure 7. Assembling a Support Rail  
4. Repeat step 3 for the other rail set.  
5. If you are installing the unit into a square-hole rack: Insert 14 cage nuts into the square-hole rack as shown in Figure 8. Align the bottom  
cage nuts on the front racks with the bottom cage nuts on the rear racks. Then align the top cage nuts with the front racks (refer to  
CAGE NUT  
CAGE NUT  
ALIGN  
ALIGN  
FRONT-MOUNT RACK  
REAR-MOUNT RACK  
Figure 8. Inserting Cage Nuts  
C3683M (3/09)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6. Attach one support rail assembly to the equipment rack in the desired location (refer to Figure 9):  
NOTE: The support rail assemblies are identical and may be used on either the right or left side of the rack.  
a. Position the ear of the front-mount rail against the front of the equipment rack. Align the top and bottom holes in the ear of the rail  
with the threaded holes (or cage nuts) in the rack.  
b. Using two 10-32 x 0.5-inch Phillips flat head screws, attach the ear of the rail to the front of the rack. Insert the screws from the  
outside of the rack, pointing toward the back of the rack.  
c. Adjust the rails to the correct depth of the equipment rack by sliding the rear-mount rail to the back of the equipment rack.  
d. Position the ear of the rear-mount rail against the rear exterior of the equipment rack. Align the top and bottom holes in the ear of the  
rail section with the threaded holes (or cage nuts) in the equipment rack.  
e. Using two 10-32 x 0.75-inch Phillips pan head screws, attach the ear of the rail to the rear of the rack. Insert the screws from the  
outside of the rack, pointing toward the front of the rack.  
7. Repeat step 6 for the second support rail assembly (refer to Figure 9).  
RACK FRONT  
RACK REAR  
(4) SCREWS  
10-32 X 0.5-INCH  
(4) SCREWS  
10-32 X 0.75-INCH  
PHILLIPS FLAT HEAD  
PHILLIPS PAN HEAD  
FRONT-MOUNT RAIL  
REAR-MOUNT RAIL  
Figure 9. Attaching Support Rails  
8. Attach one rack rail spacer to the front of the equipment rack (refer to Figure 10 on page 17):  
a. Position the bottom hole of the spacer above the ear of the front-mount rail.  
b. Insert two 10-32 x 0.5-inch Phillips flat head screws into the spacer, one in the top hole and one in the bottom hole. Leave the middle  
hole empty; the top thumbscrew on the NSM5200 will use it.  
16  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
c. Tighten the two screws to secure the spacer to the rack.  
10-32 X 0.5  
PHILLIPS  
FLATHEAD  
SPACER  
Figure 10. Attaching Rack Rail Spacers  
9. Repeat step 8 for the second spacer.  
10. Tighten the 8-32 x 0.375-inch Phillips truss head screws that were attached to the front- and rear-mount rails in steps 3 and 4.  
11. Place the unit onto the mount rails by sliding the chassis brackets onto the rails. This step may require two people to lift and slide the unit  
into place. The unit should slide in and out of the rack easily.  
NOTE: The NSM5200 stops mid-way in the rack to facilitate system fan replacement. To pull the NSM5200 completely out of the rack,  
press the clips on either side of the rack to release the unit.  
WARNING: When sliding out the NSM5200, be careful not to let the unit fall out of the rack or equipment damage or personal injury  
could result.  
Figure 11. Mounting the NSM5200 into the Rack  
C3683M (3/09)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
12. After the unit is in place, tighten the two thumbscrews to secure the unit to the rack.  
THUMBSCREW  
Figure 12. Tightening the Thumbscrews  
13. Install the cable management bracket on the rear panel as follows (refer to Figure 13):  
a. Position the bracket so that the screw holes on the unit and bracket are aligned.  
b. Insert two 6-32 x 0.25-inch Phillips pan head screws (supplied) into the screw holes located on each side of the unit.  
c. Tighten the two screws.  
d. Attach the three cable clips (supplied) to the cable management bracket.  
Figure 13. Installing the Cable Management Bracket  
14. Position the NSM5200 power supply cords along the cable management bracket, and then close the cable clips. You can also use cable ties  
(not supplied) to bundle the power supply cords.  
18  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Hard Drive Array Installation  
The NSM5200 stores data using RAID (Redundant Array of Independent Disks) technology. All NSM5200 Series recorders operate in a RAID 6  
configuration to maximize fault tolerance and enhance disk-access performance.  
The NSM5200 has a single RAID controller that manages a single array of 12 drives. The RAID 6 configuration allows any 2 out of the 12 drives  
to fail without any data loss. On any drive failure, the user is notified of the failure and the unit continues to operate.  
WARNING: If a third drive in the same array fails before either of the first two drives have been replaced, and have completed the rebuild  
process, the array will go off line and data loss will occur.  
INSTALLING HARD DRIVE CARRIERS  
After you have securely mounted the NSM5200, install the 12 hard drives in the front of the chassis. Each hard drive is already mounted in its  
own drive carrier so you can easily install and remove a hard drive, even while the unit is operating.  
NOTE: You must install all 12 hard drive carriers before you apply power to the NSM5200. The hard drive bays are numbered 1 through 12  
(starting from the left side). The hard drives are not preconfigured and can be placed in any empty hard drive bay.  
To install the hard drive carriers:  
1. Review all instructions in this section before proceeding.  
2. Make sure you protect the unit and its components, which are susceptible to damage from improper handling and ESD. Refer to the Safe  
Handling of Hard Drives document for more information.  
3. Unlock and open the front bezel.  
1
2
3
4
5
6
7
8
9
10  
11  
12  
Figure 14. Opening the Front Bezel  
C3683M (3/09)  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
4. Install each hard drive carrier as follows:  
a. Open the hard drive latch (press down and pull the spring latch).  
b. With the hard drive latch open, slide the hard drive carrier gently into an open hard drive bay (refer to Figure 15).  
Figure 15. Installing the Hard Drive Carrier  
c. Close the hard drive latch; make sure the hard drive carrier locks into place.  
5. After all 12 hard drive carriers are inserted, close and lock the front bezel.  
NOTE: During operation, monitor the unit status indicator lights to make sure that all drives are operating properly. If failure occurs, system  
alarms and error messages will also display on Endura workstations and VCD5000 video console displays.  
20  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connections  
Familiarize yourself with the NSM5200 rear panel before connecting any equipment to the unit.  
Figure 16. Rear Panel Layout  
ì Power Supply Connectors (hot-swappable) t Ethernet Port 1  
î Power Supplies (hot-swappable)  
ï Power Supply LEDs (status)  
ñ Mute button  
u VGA Port  
Serial Port  
USB 2.0 Ports (2)  
ó Fibre Channel Connector  
r Mini-SAS Connector  
s Ethernet Port 2 (reserved for future use)  
Connector for Keyboard (purple)  
Connector for Mouse (green)  
Power Supply (reserved for future use)  
CONNECTING POWER  
The NSM5200 is equipped with two hot-swappable power supplies. These autoranging power supplies adapt automatically to voltages from  
100 to 240 VAC (50/60 Hz). You should also install an uninterruptible power supply (UPS), which is not supplied. UPS devices maintain a limited  
amount of backup battery power if the main power fails. Refer to Appendix B: Installing an Uninterruptible Power Supply (UPS) on page 30 for  
more information.  
NOTE: Connect each power supply to a different branch circuit. This ensures optimal performance, reduces possible video loss, and reduces  
power leakage to a safe level.  
To connect the power supplies:  
1. Connect each power cord to a power supply connector.  
2. Connect the other end of each power cord to the appropriate power source.  
When connected, the power supply status indicators glow solid red. As soon as the unit starts, the indicators glow solid green. During operation,  
if either indicator is not lit or glows red, there is a problem with a power supply.  
C3683M (3/09)  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
CONNECTING TO THE NETWORK  
The NSM5200 supports remote administration from an Endura workstation. The NSM5200 is compatible with the entire family of Endura-ready  
devices using TCP/IP and UPnP protocols. Consult your network administrator before installing the NSM5200 to avoid possible network conflicts.  
Use the left Gigabit Ethernet adapter port  
to connect the NSM5200 to the Endura network. This is required for Endura operation.  
NOTES: For best results, you should only implement an Endura system on a 1000Base-T network. Unless the Endura installation is very small  
with a dedicated Endura network, a 100Base-T network will not support the necessary data throughput requirements.  
To connect the NSM5200 to the Endura network using a switched Gigabit Ethernet network:  
1. Connect one end of the unshielded twisted pair (UTP) cable to the left network connector on the NSM5200 rear panel. Use standard Cat5e  
or better UTP cable with RJ-45 connectors.  
NSM5200  
ENDURA NETWORK  
RESERVED  
Figure 17. Network Cable Connection  
2. Connect the other end of the UTP cable to an available port on a Pelco-approved Gigabit Ethernet switch. Contact Pelco Product Support at  
1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international) for a list of approved Gigabit Ethernet switches.  
There are two indicators on the network connector on the rear panel. The right indicator glows orange when there is a good connection  
between the NSM5200 and a Gigabit Ethernet switch that is powered up. If the indicator does not glow, check the cable and the switch.  
Disregard the left indicator, which shows network activity.  
22  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Operation  
Refer to the Web Browser manual that was shipped with the unit for details on how to access and configure the NSM5200.  
NOTE: To make sure that all diagnostic messages will appear to a system operator, leave at least one Endura workstation or VCD5000 running  
at all times.  
During operation, monitor the unit status and power supply indicator lights to make sure that all drives are operating properly. If failure occurs,  
system alarms and error messages will also display on Endura workstations and VCD5000 video console displays.  
FRONT PANEL CONTROLS AND INDICATORS  
1
2
3
4
5
6
7
8
9
10  
11  
12  
Figure 18. Front Panel Layout  
NSM5200  
Figure 19. Front Bezel Indicators  
ì
î
Pelco Badge (power indicator)  
The Pelco badge glows blue when the unit has power. If the front bezel is open, this indicator glows white.  
Drive Status  
The drive status indicator reports the operating status of each individual hard drive as follows:  
Solid Green: The read or write operation on a specific hard drive.  
Solid Red: A problem exists with the hard drive.  
Flashing Red: The unit is initializing the hard drive.  
ï
ñ
ó
r
Mute Button  
Press the mute button to silence an alarm. The user must press the mute button for each alarm event.  
Power Button  
Use the power button to turn the unit on and off (refer to Unit Startup on page 25 and Unit Shutdown on page 25).  
Compact Flash Drive  
Contains the Web configuration software  
Compact Flash Eject Button: Use this button to remove the CompactFlash drive.  
C3683M (3/09)  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
s
t
Software Status  
Green: The software is operating normally.  
Amber: A minor software malfunction is detected (for example, an excessive network packet loss).  
Red: A fatal software error has occurred: for example, ceasing to record.  
Network Port 1 Speed and Activity  
Network status (connection and speed) is indicated by one of the following conditions:  
Off: The unit is not connected to the network.  
Solid Green: The unit is connected to the network using the 1000Base-T standard.  
Solid Amber: The unit is connected to the network using the 100Base-T standard.  
Solid Red: The unit is connected to the network using the 10Base-T standard.  
NOTE: For proper operation, you must use the 1000Base-T standard.  
u
Network Port 2 Speed and Activity  
Network status (connection and speed) is indicated by one of the following conditions:  
Off: The unit is not connected to the network.  
Solid Green: The unit is connected to the network using the 1000Base-T standard.  
Solid Amber: The unit is connected to the network using the 100Base-T standard.  
Solid Red: The unit is connected to the network using the 10Base-T standard.  
NOTE: For proper operation, you must use the 1000Base-T standard.  
~í  
~â  
Unit Status  
Unit status is indicated by one of the following three colors:  
Green: The unit is functioning normally.  
Amber: The unit is in configuration mode.  
Red: The unit is in an error condition (refer to Troubleshooting on page 26).  
USB 2.0 Port: One USB 2.0 port on the front panel.  
24  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIT STARTUP  
To start the unit:  
1. Unlock and open the front bezel.  
2. Press the power button. The power indicator glows white.  
3. Close and lock the front bezel. The Pelco badge now glows blue.  
POWER BUTTON  
1
2
3
4
5
6
7
8
9
10  
11  
12  
Figure 20. Opening the Front Bezel  
UNIT SHUTDOWN  
You can shut down the NSM5200 by performing one of the following options:  
An orderly shutdown lets the unit close its files and shut down without affecting the data files. Use the orderly shutdown in most cases.  
An immediate shutdown is the same as disconnecting power and can result in corrupted data files. Only use the immediate shutdown in an  
emergency or when there is not enough time for an orderly shutdown.  
To shut down the unit:  
1. Unlock and open the front bezel.  
2. Select one of the following options:  
For an orderly shutdown, press and release the power button quickly.  
For an immediate shutdown, press and hold the power button until the unit shuts down.  
3. Close and lock the front bezel.  
C3683M (3/09)  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Troubleshooting  
If the following instructions fail to solve your problem, contact Pelco’s Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981  
(international) for assistance.  
Access the properties dialog boxes for the NSM5200 on the Endura workstation. Refer to the Endura WS5000 Software Operation manual, and  
then note the following items before contacting Pelco:  
Unit serial number: Located in the Properties window and on the product label  
Software version: Located in the Advanced Properties dialog box  
NOTE: Do not try to repair the unit yourself. Opening it immediately voids any warranty. Leave maintenance and repairs to qualified technical  
personnel. Exchange the defective unit and return it for repair.  
NSM5200  
Table B. Troubleshooting  
Possible Causes  
Problem  
Unit not ready.  
Suggested Remedy  
Check that the power indicator is lit.  
Power turned off.  
Faulty cable connections.  
Defective encoder.  
Network connectivity issues.  
Check all leads, plugs, contacts, and connections.  
Check the camera on a different encoder.  
Contact your network administrator.  
The unit is not ready for operation Voltage failure during programming  
Replace the NSM5200 and have it checked by Pelco.  
after firmware upload.  
of update file.  
Unit status indicator is red.  
Unit fan failure.  
Replace the failed fan.  
Power supply failure.  
Temperature exceeds specifications  
(internal or external).  
Check power supplies.  
Check all fans; check the external temperature.  
Unit status indicator is red and  
the power supply alarm sounds.  
Power loss to either power supply.  
Power supply module failure.  
Hard drive failure.  
Check each power supply, line voltage, and the UPS.  
Replace the failed power supply.  
Replace the failed hard drive.  
Unit status and hard drive  
indicators are red and the unit  
alarm sounds.  
POWER SUPPLIES  
The two power supplies are equipped with status indicators. Replace the appropriate power supply if a failure should occur. Table C describes  
the status by color and indicator.  
Table C. Status Indicators  
Power Supply Status Power Supply Indicator Front Panel Status Indicator  
Power Supply Audible Alarm  
Silent  
Normal  
Solid green  
Solid green  
Solid red  
Solid red  
Power problem  
Power supply failure  
Solid red  
Alarm sounds  
Not lit or solid red  
Alarm sounds  
26  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Specifications  
SYSTEM  
Operating System  
Linux  
RAID Level  
CompactFlash system drive, RAID 6 for storage drives  
Up to 9.082 TB, expandable with DAS5200s  
SAS/SATA II  
Effective Capacity  
Drive Interface  
User Interface  
Remote operation from Endura workstation or VCD5000  
Microsoft® Internet Explorer® 6.x or higher with Adobe® Flash® Player 10 or later  
Minimum Requirements  
NETWORK  
Interface  
2, 1 Gbps Ethernet RJ-45 ports (1000Base-T)  
Auxiliary Interfaces  
USB 2.0  
3 ports: 2 ports on rear panel, 1 port on front panel  
FRONT PANEL INDICATORS  
Power  
Blue Pelco badge  
Software Status  
Ethernet Port 1  
Ethernet Port 2  
Hardware Status  
Hard Drive Status  
Green, Amber, Red (based on diagnostics)  
Green, Amber, Red  
Reserved  
Green, Amber, Red  
Green, Red  
POWER  
Power Input  
100 to 240 VAC, 50/60 Hz, autoranging  
Internal, dual-redundant, hot-swappable  
Power Supply  
Power Consumption  
Operating Average  
262 W, 2.65 A, 895 BTU/H  
263 W, 2.31 A, 895 BTU/H  
254 W, 1.25 A, 868 BTU/H  
Power Cord  
1, USA standard (117 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or  
1, European standard (220 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or  
1, UK standard (250 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or  
2, Australian (250 VAC, 3 prongs, molded connector, 6 ft or 1.8 m) or  
2, Argentinian (250 VAC, 3 prongs, molded connector, 8 ft or 2.4 m)  
NOTE: Units shipped to China do not include power cords.  
ENVIRONMENTAL  
Operating Temperature  
50° to 95°F (10° to 35°C) at unit air intake  
-40° to 149°F (-40° to 65°C)  
Storage Temperature  
Operating Humidity  
20% to 80%, noncondensing  
Maximum Humidity Gradient  
Operating Altitude  
10% per hour  
-50 to 10,000 ft (-16 to 3,048 m)  
0.25 G at 3 Hz to 200 Hz at a sweep rate of 0.5 octave/minute  
Operating Vibration  
NOTE: The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configuration,  
floor layout, air conditioning strategy, and other issues. To prevent performance failure and unit damage, make sure the temperature at the unit is  
continuously within the operating temperature range.  
C3683M (3/09)  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PHYSICAL  
Construction  
Steel cabinet  
Finish  
Front bezel  
Chassis  
Gray metallic with black end caps  
Black matte finish  
Dimensions  
24.3" D x 17.0" W x 5.2" H  
(61.8 x 43.2 x 13.2 cm)  
Mounting  
Desktop (feet)  
Rack, 3 RU per unit  
(Rack rails and hardware provided)  
STANDARDS/ORGANIZATIONS  
Pelco is a member of the MPEG-4 Industry Forum  
Pelco is a member of the Universal Plug and Play (UPnP) Forum  
Pelco is a member of the Universal Serial Bus (USB) Implementers Forum  
Pelco is a contributor to the International Standards for Organization/Electrotechnical Commission (ISO/IEC) Joint Technical Committee  
1 (JTC1), “Information Technology,” Subcommittee 29, Working Group 11  
Compliance, ISO/IEC 14496 standard (also known as MPEG-4)  
Compliant with International Telecommunication Union (ITU) Recommendation G.711, “Pulse Code Modulation (PCM) of Voice Frequencies”  
(Design and product specifications subject to change without notice.)  
28  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendices  
APPENDIX A: EXPANDING VIDEO STORAGE  
You can increase the video storage capacity of the NSM5200 by adding one or more DAS5200 direct attached storage (DAS). Each DAS5200 adds  
up to 12.0 TB of total capacity (up to 9.08 TB of video storage). You can add up to seven DAS5200 units to expand the total capacity for each  
NSM5200 up to 81 TB of total capacity (up to 72.6 TB of video storage).  
NOTES:  
You do not have to shut down the NSM5200 to add a DAS5200.  
The NSM5200 has one mini-SAS connector on the rear panel; the DAS5200 has two mini-SAS connectors on the rear panel.  
A maximum of seven DAS5200s can be connected (daisy-chained) to a single NSM5200.  
To connect one or more DAS5200s to an NSM5200:  
NOTE: A rack setup is used in the following configuration.  
1. Install the NSM5200 and the DAS5200 (one or more) into a rack system.  
2. Connect a mini-SAS cable to the SAS connector on the rear panel of the NSM5200.  
3. Connect the other end of the mini-SAS cable to the top SAS connector (IN) on the rear panel of the DAS5200.  
4. For each additional DAS5200:  
a. Connect the mini-SAS cable to the bottom SAS connector (OUT) on the rear panel of the DAS5200.  
b. Connect the other end of the mini-SAS cable to the top SAS connector (IN) on the rear panel of the next DAS5200.  
Figure 21 displays an NSM5200 with three DAS5200s connected. The configuration is a daisy-chain setup.  
NSM5200  
ENDURA NETWORK  
MINI-SAS CABLE  
DAS5200  
MINI-SAS CABLE  
DAS5200  
MINI-SAS CABLE  
DAS5200  
Figure 21. DAS5200s Connected to an NSM5200  
5. Power up the DAS5200, if necessary. Refer to the DAS5200 Series Installation manual for more information.  
6. Power up the NSM5200, if necessary (refer to Unit Startup on page 25).  
The NSM5200 automatically recognizes the new DAS5200 unit within five minutes, and then puts it into service.  
C3683M (3/09)  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
APPENDIX B: INSTALLING AN UNINTERRUPTIBLE POWER SUPPLY (UPS)  
You should connect each NSM5200 to a UPS (not supplied). UPS devices maintain a limited amount of backup battery power if the main power fails.  
WARNING: Most UPS devices can be used to supply backup battery power. However, the NSM5200 does not support intelligent UPS  
devices since they usually include power management software. If you install an intelligent UPS device, do not install the power  
management software on the NSM5200.  
To connect communication and power from the UPS to the NSM5200 (refer to Figure 22):  
1. Connect a power cord from one of the NSM5200 power supplies to a standard wall socket.  
2. Connect a power cord from the UPS to a standard wall socket or other power source.  
3. Connect a power cord from the UPS to the other NSM5200 power supply. In this configuration, the unit will not lose power if either the  
power source or the UPS fails.  
4. Power up the UPS device.  
5. Power up the NSM5200, if necessary (refer to Unit Startup on page 25).  
USB  
OUTPUT POWER  
INPUT POWER  
POWER SOURCE  
UPS  
Figure 22. Connecting a UPS to an NSM5200  
30  
C3683M (3/09)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in  
material or workmanship for a period of one year after the date of shipment.  
Pelco will warrant all replacement parts and repairs for 90 days from the date of  
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid  
to a Pelco designated location. Repairs made necessary by reason of misuse,  
alteration, normal wear, or accident are not covered under this warranty.  
Exceptions to this warranty are as noted below:  
• Five years:  
Pelco assumes no risk and shall be subject to no liability for damages or loss  
resulting from the specific use or application made of the Products. Pelcos liability  
for any claim, whether based on breach of contract, negligence, infringement of  
any rights of any party or product liability, relating to the Products shall not exceed  
the price paid by the Dealer to Pelco for such Products. In no event will Pelco be  
liable for any special, incidental, or consequential damages (including loss of use,  
loss of profit, and claims of third parties) however caused, whether by the  
negligence of Pelco or otherwise.  
Fiber optic products  
TW3000 Series unshielded twisted pair (UTP) transmission products  
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and  
MC3651H-2X camera models  
• Three years:  
Pelco-branded fixed camera models (CCC1390H Series, C10DN Series,  
C10CH Series, IP3701H Series, and IX Series)  
EH1500 Series enclosures  
Spectra® IV products (including Spectra IV IP)  
Camclosure® Series (IS, ICS, IP) integrated camera systems  
The above warranty provides the Dealer with specific legal rights. The Dealer may  
also have additional rights, which are subject to variation from state to state.  
DX Series digital video recorders, DVR5100 Series digital video recorders,  
Digital Sentry® Series hardware products, DVX Series digital video  
recorders, and NVR300 Series network video recorders  
Endura® Series distributed network-based video products  
Genex® Series products (multiplexers, server, and keyboard)  
PMCL200/300/400 Series LCD monitors  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the  
following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number  
3. Details of the defect or problem  
• Two years:  
If there is a dispute regarding the warranty of a product that does not fall under  
the warranty conditions stated above, please include a written explanation with  
the product when returned.  
Standard varifocal, fixed focal, and motorized zoom lenses  
DF5/DF8 Series fixed dome products  
Legacy® Series integrated positioning systems  
Spectra III, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, and PS20  
scanners, including when used in continuous motion applications.  
Method of return shipment shall be the same or equal to the method by which the  
item was received by Pelco.  
Esprit Ti and TI2500 Series thermal imaging products  
Esprit and WW5700 Series window wiper (excluding wiper blades).  
CM6700/CM6800/CM9700 Series matrix  
RETURNS  
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100  
or (559) 292-1981 to obtain an authorization number (CA number if returned for  
credit, and RA number if returned for repair) and designated return location.  
Digital Light Processing (DLP®) displays (except lamp and color wheel). The  
lamp and color wheel will be covered for a period of 90 days. The air filter is  
not covered under warranty.  
Intelli-M® eIDC controllers  
All merchandise returned for credit may be subject to a 20 percent restocking and  
refurbishing charge.  
• One year:  
Video cassette recorders (VCRs), except video heads. Video heads will be  
covered for a period of six months.  
• Six months:  
All pan and tilts, scanners, or preset lenses used in continuous motion  
applications (preset scan, tour, and auto scan modes).  
Goods returned for repair or credit should be clearly identified with the assigned  
CA or RA number and freight should be prepaid.  
12-23-08  
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union  
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.  
REVISION HISTORY  
Manual #  
Date  
Comments  
C3683M  
3/09  
Original version.  
Pelco, the Pelco logo, Camclosure, Digital Sentry, Endura, Esprit, ExSite, Genex, Intelli-M, Legacy, and Spectra are registered trademarks of Pelco, Inc.  
Spectra III is a trademark of Pelco, Inc.  
© Copyright 2009, Pelco, Inc. All rights reserved.  
All product names and services identified throughout this document are trademarks or registered trademarks of their respective companies.  
The absence of a trademark or registered trademark from this document does not constitute a waiver of intellectual property rights.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA  
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150  
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips Clock Radio AJ130 12 User Manual
Philips Cordless Telephone CD2351S User Manual
Philips Home Security System M100A User Manual
Philips Speaker System SPA7210 17 User Manual
Philips Stereo Amplifier US2 PH61112 User Manual
Philips Stereo System SDV2710 27 User Manual
Pioneer Car Speaker TS SW3041D User Manual
Plantronics Bluetooth Headset C710 User Manual
Premier Mounts Indoor Furnishings PSD EB60 User Manual
PYLE Audio Car Video System PLD 169U User Manual