PMC09A Series
9" Color Monitor
Installation/Operation Manual
C989M (1/96)
PELCO • 300 W. Pontiac Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-209) 292-1981
FAX (800) 289-9150 or (1-209) 292-3827 • DataFAX (800) 289-9108 or (1-209) 292-0435
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC & ICES INFORMATION
Safety Precautions
(U.S.A. and Canadian Models Only)
WARNING - This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules and ICES-003 of Industry Canada. These limits are designed to
provide reasonable protection against harmful interference when the
equipment is operated in a residential installation.This equipment gener-
ates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful inter-
ference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is en-
couraged to try to correct the interference by one or more of the following
measures:
CAUTION
RISK OF ELECTRIC SHOCK.
DO NOT OPEN!
CAUTION:TO REDUCE THE RISK OF ELECTRI-
CAL SHOCK, DO NOT OPEN COVERS.NO USER
SERVICEABLE PARTS INSIDE.REFER SERVIC-
ING TO QUALIFIED SERVICE PERSONNEL.
This label may appear on the bottom of the unit due to space limitations.
-
-
-
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
The lightning flash with an arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
-
Consult the dealer or an experienced radio/TV technician for help.
Intentional or unintentional changes or modifications not expressly ap-
proved by the party responsible for compliance shall not be made. Any
such changes or modifications could void the user’s authority to operate
the equipment.
The exclamation point within an equilateral triangle is in-
tended to alert the user to presence of important operat-
ing and maintenance (servicing) instructions in the litera-
ture accompanying the appliance.
The user may find the following booklet prepared by the Federal Commu-
nications Commission helpful: “How to Identify and Resolve Radio-TV In-
terference Problems”. This booklet is available from the U.S. Government
Printing Office, Washington, DC 20402, Stock No.004-000-00345-4.
Warning
To prevent fire or shock hazard, do not expose units not spe-
cifically designed for outdoor use to rain or moisture.
Attention: Installation should be performed by qualified
service personnel only in accordance with the National
Electrical Code or applicable local codes.
Power Disconnect.Units with or without ON-OFF switches
have power supplied to the unit whenever the power cord
is inserted into the power source; however, the unit is
operational only when the ON-OFF switch is in the ON
position. The power cord is the main power disconnect
for all units.
Improper Operation. Alteration of the high voltage circuit
or changing the display tube type may result in an increase
in the x-ray emission of this unit. A unit altered in such a
way no longer meets the standards of certification and
must no longer be operated.
WARNING: Electrostatic-sensitive device. Use
proper CMOS/MOSFET handling precautions to
avoid electrostatic discharge.
NOTE: Grounded wrist straps must be worn and
proper ESD safety precautions observed when
handling the electrostatic-sensitive printed cir-
cuit boards.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
INSTALLATION
Location — The monitor should be located in a position such that the
flow of air around the unit is not restricted. Avoid heat vents or other heat
sources. Component life is greatly enhanced with moderate tempera-
tures.
DESCRIPTION............................................................... 4
INSTALLATION .............................................................. 4
OPERATION .................................................................. 5
MAINTENANCE ............................................................. 5
ILLUSTRATIONS ........................................................... 5
Power
Model
No.1
PMC09A
Rated
Voltage
120 VAC, 60 Hz
Voltage
Range
108 to 132
198 to 264
Nominal Color
Power 2
0.63 A
0.31 A
System
NTSC
CCIR PAL
UNPACKING
PMC09A-X 230 VAC.50Hz
Unpack carefully. This is electronic equipment and should be handled
with care.
1. These units may be supplied with grounded power cords; ground-
ing should not be defeated.
The shipping carton is the safest container in which the unit may be trans-
ported. Save it for possible future use.
2. At rated voltage.
DESCRIPTION
Video Cabling — To assure good picture quality, use 75 ohm coaxial
cable and be sure the unit is terminated correctly.Cable attenuation should
also be considered on long cable runs and adequate video signal levels
provided.
The PMC09A Series are 23-cm (9-inch) color video monitors for special-
ized surveillance and industrial CCTV applications.These color monitors
provide excellent picture quality and convenient control of functions.They
are ideal for time lapse and event alarm VCR systems, or color video
multiplexers.
When the monitor is located at the end of the cable run, use the VIDEO IN
connector on the rear of the chassis and set the termination switch to the
“75 Ω” position. Use the VIDEO OUT connector when the video cable is
“looped through” the monitor to other video equipment and set the termi-
nation switch on to the last piece of equipment on the line to the “75 Ω”
position.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
5. When video is looping through the monitor to another video device,
properly switch the termination switch on the rear panel of the moni-
tor from the 75 ohm position to the HiZ position (High Impedance).
OPERATION
To obtain the best possible operation from this product, the following setup
procedure should be followed when installing the monitor. The setup pro-
cess is very simple and straightforward and involves nothing more than
attaching a source of color video and adjusting the controls to the detent
position. This provides a factory preset condition which allows normal
viewing. If contrast, brightness, chrome or phase need to be fine tuned,
please use the following procedures to obtain the best picture. Note that
the center detent position on all front panel controls is the normal setting;
a subcontrol is provided for presetting each control. The subcontrol ad-
justments should be adjusted by a qualified service technician only.
6. NOTE - There are no external Vertical or Horizontal Hold controls .
The monitor contains circuitry to lock the synchronization internally.
7. NOTE - Overdrive of the white portions of the video, sufficient to
cause blooming, can significantly shorten the service life of the CRT.
Always adjust the BRIGHT and CONTRAST controls to the center
detent position or towards a minimum setting to enhance monitor
life expectancy.
1. Connect a camera or other source of standard color video signal to
the VIDEO IN of the monitor.
MAINTENANCE
This unit contains no user-serviceable components.Main-
tenance, beyond the adjustments described herein, should
be attempted only by trained technical personnel.
2. Turn on the POWER switch; LED indicator will light. Allow the moni-
tor to warm up for about 30 seconds. Adjust the PHASE control
(applies to PMC09A only), to the center detent position. If neces-
sary, for best tint adjustment, rotate the Phase control to obtain the
desired picture.
3. Adjust the CHROMA control to the center detent position.The monitor
screen should appear to provide a color image. If the image re-
quires more color saturation rotate the control clockwise. If colors
appear too saturated, adjust the control counter-clockwise.
4. Adjust BRIGHT and CONTRAST controls to the center detent posi-
tion. If dark scene areas require enhancement, the BRIGHT control
can be rotated clockwise. If the “black level”, which determines the
darkest portion of the picture, appears too light, rotate the BRIGHT
control counter-clockwise.
ILLUSTRATIONS
Front Panels
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ILLUSTRATIONS (Cont’d)
Rear Panel
Typical Applications
6
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY AND RETURN
INFORMATION
RETURNS
WARRANTY
In order to expedite parts returned to the factory for repair or
credit, please call the factory at (800) 289-9100 or (209)
292-1981 to obtain an authorization number (CA number if
returned for credit, and RA number if returned for repair).
Goods returned for repair or credit should be clearly identified
with the assigned CA/RA number and freight should be
prepaid. All merchandise returned for credit may be subject to
a 20% restocking and refurbishing charge.
Pelco will repair or replace, without charge, any merchandise
proved defective in material or workmanship for a period of
one (1) year after the date of shipment. Exceptions to this
warranty are as noted below:
•
Six (6) months on all pan and tilts, scanners or preset
lenses used in continuous motion applications (e.g.,
preset scan, tour and auto scan modes).
•
•
Two (2) years on Legacy®, Intercept® and CM8500/
CM9500/CM9750 Matrix products.
Ship freight prepaid to:
Pelco
300 West Pontiac Way
Clovis, CA 93612-5699
Two(2)yearsonWW5700serieswindowwiper(excluding
wiper blades).
Pelco will warranty all replacement parts and repairs for 90
days from the date of shipment. All goods for warranty work
shall be sent freight prepaid to our Clovis, California facility.
Repairs made necessary by reason of misuse, alteration,
normal wear, or accident are not covered under this warranty.
Pelcoisnotliableforanyincidentalorconsequentialexpenses
or liability incurred by the customer as a result of field repair,
installation, or any other reason.
The above warranty is in lieu of any other expressed or implied
warranty, condition, or guarantee by Pelco of the equipment
listed herein. Pelco makes no warranties except for intended
useandwillnotbeliableforanyloss, damage, orcostsarising,
whether consequential or incidental, from the use of said
merchandise.
This warranty gives you specific legal rights. You may also
have additional rights, which are subject to variation from
state to state.
If a warranty repair is required, contact Pelco at (800) 289-
9100or (209)292-1981for a Repair Authorization number
(RA), and provide the following information:
1. Model and serial number
2. Dateofshipment,P.O.number,SalesOrdernumber,
or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which
does not fall under the warranty conditions stated above,
please include a written explanation with the product when
returned.
Ship freight prepaid to:
Pelco
300 West Pontiac Way
Clovis, CA 93612-5699
Method of return shipment shall be the same as method by
which the repair item is received by Pelco.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
®
Pelco
300 West Pontiac Way, Clovis, CA 93612-5699 (209) 292-1981 • (800) 289-9100
FAX (800) 289-9150 or (209) 292-3827 • DataFAX (800) 289-9108 or (209) 292-0435
International customers call 1-209-292-1981 or FAX 1-209-348-1120
(Product specifications subject to change without notice.)
C989M
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|