IMPORTANT SAFETY INSTRUCTIONS  
WARNING: When using electrical products, basic cautions should always be followed, including the following:  
1.  
Read these instructions.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
Keep these instructions.  
Heed all warnings.  
Follow all instructions.  
Do not use this apparatus near water.  
Clean only with a dry cloth.  
Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions.  
Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers)  
that produce heat.  
9.  
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one  
wider than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third prong is  
provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the  
obsolete outlet.  
10.  
11.  
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point  
they exit from the apparatus.  
Note for UK only: If the colors of the wires in the mains lead of this unit do not correspond with the terminals in your  
plug‚ proceed as follows:  
a) The wire that is colored green and yellow must be connected to the terminal that is marked by the letter E‚ the earth  
symbol‚ colored green or colored green and yellow.  
b) The wire that is colored blue must be connected to the terminal that is marked with the letter N or the color black.  
c) The wire that is colored brown must be connected to the terminal that is marked with the letter L or the color red.  
Only use attachments/accessories provided by the manufacturer.  
12.  
13.  
Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a  
cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.  
14.  
15.  
Unplug this apparatus during lightning storms or when unused for long periods of time.  
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any  
way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus,  
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.  
16.  
Never break off the ground pin. Write for our free booklet “Shock Hazard and Grounding.” Connect only to a power  
supply of the type marked on the unit adjacent to the power supply cord.  
17.  
18.  
If this product is to be mounted in an equipment rack, rear support should be provided.  
Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in suscep-  
tibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently intense noise  
for a sufficient time. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the  
following permissible noise level exposures:  
Duration Per Day In Hours  
Sound Level dBA, Slow Response  
8
6
4
3
2
90  
92  
95  
97  
100  
102  
105  
110  
115  
1 1⁄  
2
1
1
2
1
4
or less  
According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or protectors to the  
ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss, if exposure  
is in excess of the limits as set forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is  
recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be  
protected by hearing protectors while this unit is in operation.  
SAVE THESE INSTRUCTIONS!  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENGLISH  
MMAMixer/Power Amplifier Systems  
Description:  
The MMA81502‚ 8752 and 8352 are high-quality‚ industrial-grade audio mixer/amplifiers.  
Designed for flexibility in application‚ these mixer/amps represent the latest‚ state-of-the-art  
technology in mixer/amplifier design. Powerful‚ yet easy to use‚ the MMA series delivers  
amazing sonic performance. Low-noise design and features applicable to “real world”  
situations make these units ideal for audio applications where a powerful‚ compact  
mixer/amplifier with multiple inputs and outputs are required.  
This manual was written to provide as much information as possible for your new Peavey  
Architectural Acoustics product. It is our sincere desire that you enjoy your purchase.  
We feel that the best way to fully enjoy any purchase is to have an in-depth understanding of  
the product’s features‚ functionality and performance characteristics. We hope that this  
manual‚ along with the manuals of our other products‚ will provide this. If you require  
additional information not provided in this manual‚ please let us know. We are continuously  
looking for better ways to provide information about our products and your input is always  
appreciated.  
If you have a comment about this manual or would like to make a suggestion‚ please write to:  
Peavey Electronics Corp.‚ Architectural Acoustics Division‚ 711 A Street‚ Meridian MS 39301 or  
Features:  
· nine channel mixer/power amplifier system  
· eight input ports accept MMAplug-in modules  
· dedicated program input  
· high and low EQ controls  
· switchable low cut filter  
· external volume control capability  
· two mute buses  
· preamp output/power amp input patch capability  
· short circuit and thermal protection  
· SPS(Speaker Protection System) circuitry with indicator  
· 4 Ohm direct output  
· 8 Ohm, 25 Volt, and 70 Volt transformer isolated power outputs  
(MMA81502 120V only)  
· 8 Ohm, 70 Volt, and 100 Volt transformer isolated power outputs (MMA81502 230V only)  
· 8 Ohm/25 Volt, 70 Volt, and 100 Volt transformer isolated power  
outputs (MMA8752)  
· 8 Ohm, 70 Volt, and 100 Volt transformer isolated power outputs (MMA8352)  
· AC convenience outlet (120V units only)  
· optional rack mounting with included rack ears  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
· presentation rooms  
· board rooms  
· courtrooms  
· convention centers  
· paging systems  
· background music  
· retail spaces  
Applications  
· auditoriums  
· lecture halls  
· restaurants  
· meeting rooms  
1. Power Indicator  
Front Panel  
The green LED indicates when AC power is supplied to the unit and the power  
switch is on.  
2. Signal Level Indicator  
The green LED indicates signal presence at the amplifier output.  
3. SPSIndicator  
The red LED indicates when SPS circuitry is active. SPS eliminates power amplifier  
clipping.  
4. Input Channel Level Controls  
Controls the signal level of the input channels 1–8 respectively to the mix bus.  
5. Input Channel Signal Status Indicators  
Indicates signal presence (green) and peak (red) conditions of the channel input signal  
prior to the level controls. Be cautious not to overdrive the mix bus.  
6. Program Input Level Control  
Controls the signal level of the program input to the mix bus.  
7. Low EQ Control (Bass)  
This is an active equalization control that adjusts the low frequency. Clockwise rotation  
boosts low frequencies and counter-clockwise rotation provides a cut in low frequencies  
( 10 dB). EQ is flat at center detent.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. High EQ Control (Treble)  
This is an active equalization control that adjusts the high frequency. Clockwise rotation  
boosts high frequencies and counter-clockwise rotation provides a cut in high frequencies  
( 10 dB). EQ is flat at center detent.  
9. EQ Bypass Switch  
Selects the status of the EQ. When OUT the EQ controls are active. When IN the EQ  
controls are inactive and the EQ is flat.  
10. Mute Bus Indicators  
The red LEDs indicate the status of each mute bus. Each LED lights when its appropriate  
mute bus is activated.  
11. Master Level Control  
Controls the overall level of the system.  
12. AC Power Receptacle  
Rear Panel  
This receptacle is for the IEC line cord (included) that provides AC power to the unit.  
Never break off the ground pin on any equipment. It is provided for your safety. If the  
outlet used does not have a ground pin, a suitable grounding adapter should be used and  
the third wire should be grounded properly. To prevent the risk of shock or fire hazard,  
always be sure that the mixer and all other associated equipment are properly grounded.  
13. Power Switch  
This rocker switch applies mains power to the unit.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
14. Fuse  
The fuse is located within the cap of the fuse holder. If the fuse fails, THE FUSE MUST BE  
REPLACED WITH THE SAME TYPE AND VALUE IN ORDER TO AVOID DAMAGE TO THE  
EQUIPMENT AND TO PREVENT VOIDING THE WARRANTY. If the amp repeatedly blows  
fuse, it should be taken to a qualified service center for repair.  
WARNING: The fuse should only be replaced when the power cord has been disconnected  
from its power source!  
15. AC Outlet (Unswitched)  
Provides AC power for auxiliary equipment with power consumption less than 300 Watts.  
not  
This outlet is  
controlled by the power switch (#13).  
16. Outputs  
A direct output and transformer isolated outputs are provided to allow proper interface  
between the amplifier and the loudspeaker system. The direct output allows connection  
remove the jumper  
to a 4 Ohm speaker system. To use this output,  
between the 4 Ohm  
terminal and the XFMR LINK terminal. Connect the loudspeaker system to the 4 Ohm and  
GND terminals.  
For transformer isolated outputs, ensure the jumper is inserted between the XFMR LINK  
terminal and the 4 Ohm terminal, then connect load between the desired output and  
COM. The Low Cut switch (#19) should be ON. See LOUDSPEAKER OUTPUT CONNECTIONS  
below for details.  
17. Module Input Ports 1–6  
Accepts optional PLUG-IN MODULES. The modules should be selected by installation  
requirements. These ports accept and support PLUG-IN MODULES that do not require a  
+5V power supply. For details, refer to the individual PLUG-IN MODULE Instruction Guide.  
CAUTION: PLUG-IN MODULES should not be inserted or removed while the  
mixer/amplifier is turned on.  
NOTE: No more than two of the optional OPMOutput Power Modules may be used in  
each MMA mainframe.  
18. Module Input Ports 7–8  
Accepts optional PLUG-IN MODULES. The modules should be selected by installation  
requirements. These ports accept and support specific PLUG-IN MODULES that do require  
a +5V power supply, however any PLUG-IN MODULE may be utilized. For details, refer to  
the individual PLUG-IN MODULE Instruction Guide.  
CAUTION: PLUG-IN MODULES should not be inserted or removed while the  
mixer/amplifier is turned on.  
NOTE: No more than two of the optional OPMOutput Power Modules may be used in  
each MMA mainframe.  
19. Low cut switch  
Provides a 6 dB/octave low frequency roll-off at 60 Hz. To be used when the transformer  
isolated power outputs are connected to the loudspeaker system.  
20. Preamplifier Out  
Provides a line level output of Master Level mix output to drive external devices such as  
signal processors, hearing assistance systems, or recording equipment. The input  
impedance of the equipment should be greater than 600 Ohms.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
21. Power Amplifier Input  
Provides a direct input to the power amplifier with an input sensitivity of 1 Volt. When an  
RCA phono plug is inserted into this input, the connection between the preamp output and  
the power amp input is internally disconnected allowing direct access to the power  
amplifier. Using this input along with the preamplifier output (#9), a signal processor can  
be inserted between the mixer and the power amplifier.  
22. Bridge In/Out  
Provides an output signal that is independent of the Master level, Low EQ, and High EQ  
controls. It also may be used as a mixing output point when the similar terminal of another  
mixer/amplifier is connected to this terminal. A separate tape recorder output may be  
taken from this point without interaction of EQ and Master level control. The input  
impedance of the equipment connected to this terminal should be greater than 10k Ohms.  
23. Program Input  
Provides an auxiliary input that accepts signals from other sources such as another mixer  
or mixer/amplifier. The signal level at this input is controlled by the PROGRAM level  
control on the front panel and is fed to the mix bus. The Program input may be regarded as  
“Channel 9” without PLUG-IN MODULE capability.  
NOTE: This input is muted whenever the Mute 1 bus is activated (#24).  
24. Ext Mute 1/2  
When either of these terminals is connected to the Shield terminal (SHD), the respective  
mute bus is activated and fed to any PLUG-IN MODULES utilizing its muting function. For  
details about the module’s muting function, refer to the individual PLUG-IN MODULE  
Instruction Guide.  
25. External Volume Control  
These connections allow the use of an external (remote) master volume control. For  
complete command of the volume from the remote control, the front panel Master Level  
control (#1) must be set at its maximum (10) position. The remote volume control should  
be connected as shown in Figure 1, with the clockwise terminal connected to the Shield  
(SHD); the wiper connected to the Control (C); and the counterclockwise terminal  
connected to the Voltage (V). Using a 10k Ohm linear taper potentiometer will provide  
approximately 30 dB attenuation, while using a 100k Ohm linear taper potentiometer will  
provide approximately 60 dB attenuation. See Figure 1.  
Figure 1  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing Rack-mount Ears  
This unit can be rack-mounted in a standard EIA equipment rack with the two included rack ears. To  
attach the ears‚ simply remove the three screws already in the front of each side of the unit and  
align the ears with the appropriate mounting holes. It may be desirable to remove the rubber feet  
from the bottom of the unit when mounting in an equipment rack.  
Note: To provide adequate ventilation‚ leave at least one rack space between units when multiple  
amplifiers are mounted in the same equipment rack. For proper operation of this unit‚ do not place  
within 6" of any wall or combustible surface.  
Figure 2  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
There are eight INPUT PORTS for PLUG-IN MODULES. Select the appropriate modules for each  
application. Plug the modules into the INPUT PORTS. Slide them between the card-edge guide  
Input Connections  
Figure 3  
rails and secure them with the provided screws as shown in  
. Ensure screws are  
sufficiently tightened for proper grounding. For connection details, refer to the individual PLUG-  
IN MODULE Instruction Guide.  
CAUTION: Plug-in Modules should not be inserted or removed while the mixer/amplifier is turned  
on. Cover unoccupied INPUT PORTS with provided blank panels and secure with screws.  
Figure 3  
Loudspeaker Output Connections  
The loudspeaker outputs of the mixer/amplifier are 4 Ohms, 8 Ohms, 25V and 70V. Connect the  
loudspeaker system to any ONE of these outputs. Class 2 wiring may be used.  
MMA81502 (120V)  
There are two types of output: 4 Ohm Direct Output;  
8 Ohm, 25V, and 70V via Output Transformer  
The method of connection differs in each case. Refer to Figure 4. If using the transformer  
isolated outputs be sure that the Low Cut switch is ON.  
Note: Impedance values shown in Figure 4 indicate total loudspeaker system (load) impedance.  
Figure 4  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connect  
The loudspeaker outputs of the mixer/amplifier are 4 Ohms, 8 Ohms, 70V and 100V.  
MMA81502 (230V)  
the loudspeaker system to any ONE of these outputs.  
Class 2 wiring may be used.  
There are two types of output: 4 Ohm Direct Output;  
8 Ohm, 70V, and 100V via Output Transformer  
Figure 5  
The method of connection differs in each case. Refer to  
isolated outputs be sure that the Low Cut switch is ON.  
. If using the transformer  
Note: Impedance values shown in Figure 5 indicate total loudspeaker system (load) impedance.  
Figure 5  
The loudspeaker outputs of the mixer/amplifier are 4 Ohms, 8 Ohms/25V, 70V and 100V.  
Connect the loudspeaker system to any ONE of these outputs. Class 2 wiring may be used.  
MMA8752 (120/230V)  
There are two types of output: 4 Ohm Direct Output;  
8 Ohm/25V, 70V, and 100V via Output Transformer  
The method of connection differs in each case. Refer to Figure 6. If using the transformer  
isolated outputs be sure that the Low Cut switch is ON.  
Note: Impedance values shown in Figure 6 indicate total loudspeaker system (load) impedance.  
Figure 6  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connect the  
The loudspeaker outputs of the mixer/amplifier are 4 Ohms, 8 Ohms, 70V and 100V.  
loudspeaker system to any ONE of these outputs.  
MMA8352 (120V)  
Class 2 wiring may be used.  
There are two types of output: 4 Ohm Direct Output;  
8 Ohm, 70V, and 100V via Output Transformer  
Figure 7  
The method of connection differs in each case. Refer to  
isolated outputs be sure that the Low Cut switch is ON.  
. If using the transformer  
Note: Impedance values shown in Figure 7 indicate total loudspeaker system (load) impedance.  
Figure 7  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Block Diagram  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Rated Output Power:  
MMA81502: 150 W  
Rear Panel Features:  
Preamp Output  
MMA8752: 75 W  
MMA8352: 35 W  
Power Amp Input  
Program Input  
Bridge In/Out  
Output Regulation:  
External Mute Terminals  
External Volume Control  
Plug-in Module Ports 1–8  
Loudspeaker Output Terminals  
AC convenience outlet (120V units only)  
Power Switch  
Direct Out: 0.5dB  
Transformer Out: 1.0dB  
Frequency Response:  
Power Amplifier:  
0.5 dB, 20 Hz to 20 kHz, Direct Out  
1.0 dB, 50 Hz to 20 kHz, Transformer Out  
Preamplifier:  
1.0 dB, 20 Hz to 20 kHz  
Fuse  
IEC Power Connector  
Muting:  
MMA input module with muting capability overrides  
THD:  
the Program Input on Mute 1 bus  
Mute 1 and Mute 2 bus activation with switch  
contact closure via screw terminals  
Power Amplifier: 0.05% (1kHz)  
Preamplifier: 0.10% with nominal gain settings  
Power Bandwidth:  
Power Requirements:  
Direct Out: 10 Hz to 70 kHz  
MMA81502 (120V): 300 Watts, 120 Vac, 60 Hz  
Transformer Out: 30 Hz to 40 kHz  
MMA81502 (230V): 300 Watts, 230 Vac, 50/60 Hz  
MMA8752 (120V): 180 Watts, 120 Vac, 60 Hz  
MMA8752 (230V): 180 Watts, 230 Vac, 50/60 Hz  
MMA8352 (120V): 100 Watts, 120 Vac, 60 Hz  
Signal/ Noise:  
(22 Hz–22 kHz) typical  
All controls CCW: 100 dB  
All controls nom: 95 dB  
Master Level Max: 77 dB  
Dimensions:  
19.00” (W) X 13.25” (D) X 3.45” (H) with rack ears  
and without feet (483 mm X 337 mm X 88 mm)  
17.00” (W) X 13.25” (D) X 4.00” (H) without rack ears  
and with feet (432 mm X 337 mm X 102 mm)  
Outputs:  
Direct Out: 4 Ohms  
Transformer Isolated: 8 Ohms, 25V, 70 V  
(MMA81502, 120V only)  
8 Ohms, 70 V, 100 V (MMA81502, 230V only)  
8 Ohms/25V, 70 V, 100 V (MMA8752)  
8 Ohms, 70 V, 100 V (MMA8352)  
Weight:  
MMA81502: 28.3 lbs. (12.9 kg)  
MMA8752: 25.0 lbs. (11.4 kg)  
MMA8352: 21.1 lbs. (9.6 kg)  
Pre Out: 1 V nom; +21 dBu max at 100 Ohms  
Bridge In/Out: 100 mV at 3.3k Ohms  
Color:  
Black  
Input Sensitivity:  
Program In: 100 mV at 10k Ohms  
Bridge In/Out: 100 mV at 3.3k Ohms  
Power In: 1 Volt at 20k Ohms  
Tone Controls:  
Low EQ: 10 dB at 100 Hz  
High EQ: 10 dB at 10 kHz  
Front Panel Features:  
Channel 1–8 Level Controls  
Program Input Level Control  
High EQ Control  
Low EQ Control  
EQ Bypass Switch  
Master Level Control  
Input Channel Signal Level Indicators (Signal  
Presence: green; Signal Peak: red)  
Mute Bus Status Indicators  
Power Amplifier Signal Presence Indicator  
SPS™ Indicator  
Power On Indicator  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DEUTSCH  
MMAMixer/Power Amplifier Systems  
Description:  
Die Modelle MMA81502, 8752 und 8352 sind hochwertige Audio-Mischpulte/Verstärker für  
den gewerblichen Einsatz. Diese Mischpulte/Verstärker zeichnen sich durch ihre Flexibilität in  
der Anwendung aus und sind mit der modernsten und fortschrittlichsten Technologie im  
Bereich dieser Geräte ausgestattet. Die leistungsfähige und gleichzeitig anwenderfreundliche  
MMA-Baureihe bietet eine ausgezeichnete Klangleistung. Geräuscharme Konstruktion und für  
„reale" Situationen entwickelte Merkmale machen diese Geräte zur idealen Lösung für Audio-  
Einsätze, bei denen ein leistungsfähiger und kompakter Mischpult/Verstärker mit vielseitigen  
Ein- und Ausgängen benötigt wird.  
Dieses Handbuch soll Ihnen möglichst viele Informationen zu Ihrem neuen Produkt von Peavey  
Architectural Acoustics bieten. Wir wünschen uns, dass Sie viel Freude mit Ihrem neuen Gerät  
haben.  
Damit Sie Ihr neu gekauftes Gerät optimal nutzen können und viel Freude an ihm haben,  
sollten Sie sich mit seinen Merkmalen, Funktionen und Leistungskennwerten vertraut machen.  
Wir hoffen, dass diese Anleitung zusammen mit den Bedienungsanleitungen für unsere  
anderen Produkte dies ermöglicht. Sollten Sie weitere Informationen benötigen, die in dieser  
Anleitung nicht enthalten sind, teilen Sie uns dies bitte mit. Wir sind ständig bemüht, Sie noch  
besser über unsere Produkte zu informieren, und Ihre Anregungen oder Kommentare sind  
immer willkommen.  
Sollten Sie Anmerkungen oder Anregungen zu diesem Handbuch haben, senden Sie diese bitte  
an: Peavey Electronics Corp., Architectural Acoustics Division, 711 A Street, Meridian, MS  
dafür, dass Sie sich für Peavey Architectural Acoustics entschieden haben!  
· Neun-Kanal-Mischpult/Verstärker-System  
· Acht Eingänge, die für MMA-Plug-in-Module ausgelegt sind  
Features:  
· Eigener Programmeingang  
· High- und Low-EQ-Regler  
· Zuschaltbarer Tiefpassfilter  
· Funktion zur externen Lautstärkeregelung  
· Zwei Mute-Busse  
· Anschlussmöglichkeiten für Vorverstärkerausgang und Verstärkereingang  
· Kurzschluss- und Thermoschutz  
· SPS- (Speaker Protection System) Schaltung mit Anzeige  
· Direkter Ausgang, 4 Ohm  
· Leistungsausgänge, 8 Ohm, 25 Volt und 70 Volt, trafoisoliert (MMA81502 nur 120 Volt)  
· Leistungsausgänge, 8 Ohm, 70 Volt und 100 Volt, trafoisoliert (MMA81502 nur 230 Volt)  
· Leistungsausgänge, 8 Ohm, 25 Volt, 70 Volt und 100 Volt, trafoisoliert (MMA8752)  
· Leistungsausgänge, 8 Ohm, 70 Volt und 100 Volt, trafoisoliert (MMA8352)  
· Wechselstromsteckdose (nur Geräte mit 120 V)  
· Optionale Rack-Montage mit beiliegenden Rack-Ösen  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
·Präsentationsräume  
· Sitzungssäle  
· Messe- und Konferenzzentren  
· Paging-Systeme  
Einsatzbereiche  
· Gerichtssäle  
· Hörsäle  
· Vorlesungssäle  
· Besprechungsräume  
· Hintergrundmusik  
· Einzelhandelsgeschäfte  
· Restaurants  
1. Betriebsanzeige  
Front Panel  
Die grüne LED leuchtet auf, wenn das Gerät mit Wechselstrom versorgt wird und eingeschaltet  
ist.  
2. Signal-Level-Anzeige  
Diese grüne LED leuchtet auf um anzuzeigen, dass ein Signal am Verstärkerausgang vorliegt.  
3. SPSAnzeige  
Die rote LED leuchtet auf, wenn die SPS-Schaltung aktiviert ist. SPSverhindert ein Clipping  
des Verstärkers.  
4. Input Channel Level Regler  
Mit diesem Regler wird der Pegel der Eingangskanäle 1-8 bzw. des zum Mix-Bus gesendeten  
Signals eingestellt.  
5. Input-Channel-Signal-Status-Anzeigen  
Zeigt an, ob ein Kanaleingangssignal vorhanden ist (grün) oder ob es Signalspitzen erreicht  
(rot) (vor den Pegelreglern). Der Mix-Bus darf nicht übersteuert werden.  
6. Program-Input-Level-Regler  
Mit diesem Regler wird der Signalpegel des Programmeingangs zum Mix-Bus eingestellt.  
7. Low-EQ-Regler (Bass)  
Hier handelt es sich um einen aktiven Equalizer-Regler, mit dem die niedrigen Frequenzen  
eingestellt werden. Durch Drehen im Uhrzeigersinn werden die niedrigen Frequenzen ange-  
hoben, durch Drehen im entgegengesetzten Uhrzeigersinn werden sie abgesenkt ( 10 dB).  
Steht der EQ-Regler auf der mittleren arretierten Position, sind die Frequenzen unverändert.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. High-EQ-Regler (Treble)  
Hier handelt es sich um einen aktiven Equalizer-Regler, mit dem die hohen Frequenzen  
eingestellt werden. Durch Drehen im Uhrzeigersinn werden die hohen Frequenzen angehoben,  
durch Drehen im entgegengesetzten Uhrzeigersinn werden sie abgesenkt ( 10 dB). Steht der  
EQ-Regler auf der mittleren arretierten Position, sind die Frequenzen unverändert.  
9. EQ-Bypass-Schalter  
Hiermit wird der Status des EQ ausgewählt. Ist er ausgeschaltet, sind die EQ-Regler aktiv. Ist er  
eingeschaltet, sind die EQ-Regler inaktiv und die Frequenzen sind unverändert.  
10. Mute-Bus-Anzeigen  
Die roten LEDs zeigen den Status der Mute-Busse an. Ist ein Mute-Bus aktiviert, leuchtet die  
zugehörige LED auf.  
11. Master-Level-Regler  
Mit diesem Regler wird der Gesamtpegel des Systems eingestellt.  
14  
17  
19  
13  
12  
12  
20  
21  
22  
23  
24  
25  
12 Wechselstromsteckdose  
Rear Panel  
Diese Steckdose steht für das beiliegende IEC-Netzkabel zur Verfügung, über das das  
Gerät mit Wechselstrom versorgt wird.  
Der Erdungsstift darf in keinem Fall an irgendeinem Gerät entfernt werden. Er ist zu Ihrer  
Sicherheit vorhanden. Ist die verwendete Steckdose nicht mit einem Erdungsstift ausges-  
tattet, muss ein geeigneter Erdungsadapter verwendet und die dritte Ader korrekt geerdet  
werden. Um die Gefahr eines elektrischen Schlages oder eines Brandes zu verhindern,  
müssen der Mischpult sowie alle anderen zugehörigen Ausrüstungsteile korrekt geerdet  
werden.  
13. Netzschalter  
Über diesen Wippschalter wird das Gerät mit Netzstrom versorgt.  
14. Fuse  
Die Sicherung befindet sich im Deckel der Sicherungsfassung. Sollte die Sicherung ausfall-  
en, MUSS SIE DURCH EINE SICHERUNG DERSELBEN ART UND MIT DENSELBEN WERTEN  
ERSETZT WERDEN, UM EINE BESCHÄDIGUNG DER GERÄTE UND EINEN VERFALL DER  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GARANTIE ZU VERHINDERN. Sollte die Sicherung des Gerätes wiederholt durchbrennen,  
muss es zu einem qualifizierten Servicecenter zur Reparatur gebracht werden.  
ACHTUNG: Die Sicherung darf nur ausgetauscht werden, wenn das Netzkabel von der  
Stromquelle abgetrennt wurde!  
15. Wechselstromanschluss (nicht geschaltet)  
Diese Steckdose liefert Strom für Zusatzgeräte mit einer Leistungsaufnahme von unter  
300 W. Diese Steckdose wird nicht über den Netzschalter (Nr. 13) geregelt.  
16. Outputs  
Es sind ein direkter Ausgang und trafoisolierte Ausgänge vorhanden, über die ein korrek-  
ter Anschluss zwischen Verstärker und Lautsprechersystem hergestellt werden kann. Der  
direkte Ausgang ermöglicht den Anschluss an ein 4-Ohm-Lautsprechersystem. Um diesen  
Ausgang zu verwenden, trennen Sie die Brücke zwischen der 4-Ohm-Klemme und der  
XFMR-LINK-Klemme. Schließen Sie das Lautsprechersystem an die 4-Ohm- und GND-  
Klemmen an.  
Stellen Sie bei den trafoisolierten Ausgängen sicher, dass die Brücke zwischen XFMR-  
LINK-Klemme und 4-Ohm-Klemme angeschlossen ist, und schließen Sie die Last zwischen  
dem gewünschten Ausgang und COM an. Der Low-Cut-Schalter (Nr. 19) muss auf ON ste-  
hen. Nähere Informationen dazu erfahren Sie im Abschnitt ANSCHLUSS DER  
LAUTSPRECHERAUSGÄNGE.  
17. Module Input Ports 1–6  
Hier können die als Zubehör erhältlichen PLUG-IN-MODULE eingesteckt werden. Die  
Module müssen entsprechend den Installationsanforderungen ausgewählt werden. Für  
diese Anschlüsse können PLUG-IN-MODULE verwendet werden, die nicht mit +5V  
Stromversorgung arbeiten. Nähere Informationen dazu erfahren Sie aus der  
Bedienungsanleitung des jeweiligen PLUG-IN-MODULS.  
ACHTUNG: PLUG-IN-MODULE dürfen nicht eingesteckt oder herausgezogen werden,  
solange der Mischpult/Verstärker eingeschaltet ist.  
HINWEIS: In einen MMA-Rechner dürfen nicht mehr als zwei der als Zubehör erhältlichen  
OPMOutput Power Modules eingesteckt werden.  
18. Module Input Ports 7-8  
Hier können die als Zubehör erhältlichen PLUG-IN-MODULE eingesteckt werden. Die  
Module müssen entsprechend den Installationsanforderungen ausgewählt werden. Für  
diese Anschlüsse können spezielle PLUG-IN-MODULE verwendet werden, die mit +5V  
Stromversorgung arbeiten, es können jedoch auch alle anderen PLUG-IN-MODULE ver-  
wendet werden. Nähere Informationen dazu erfahren Sie aus der Bedienungsanleitung  
des jeweiligen PLUG-IN-MODULS.  
ACHTUNG: PLUG-IN-MODULE dürfen nicht eingesteckt oder herausgezogen werden,  
solange das Mischpult bzw. der Verstärker eingeschaltet sind.  
HINWEIS: In einen MMA-Rechner dürfen nicht mehr als zwei der als Zubehör erhältlichen  
OPM™ Output Power Modules eingesteckt werden.  
19. Low-Cut-Schalter  
Hiermit kann eine Dämpfung von 6 dB/Oktave bei 60 Hz erzielt werden. Dieser Schalter  
wird verwendet, wenn die trafoisolierten Ausgänge ans Lautsprechersystem  
angeschlossen werden.  
20. Preamplifier Out  
Dieser Anschluss bietet einen Line-Pegelausgang des Master-Level-Mix-Ausgangs, um  
externe Geräte wie etwa Signalprozessoren, Hörhilfssysteme oder Aufzeichnungsgeräte  
zu treiben. Die Eingangsimpedanz der Geräte sollte über 600 Ohm betragen.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21. Power Amplifier Input  
Dieser Anschluss bietet einen direkten Eingang zum Verstärker mit einer  
Eingangsempfindlichkeit von 1 Volt. Wird ein RCA-Phono-Stecker in diesen Eingang  
eingesteckt, wird der Anschluss zwischen Vorverstärkerausgang und Verstärkereingang  
intern getrennt, so dass die Signale direkt an den Verstärker gesendet werden. Über  
diesen Eingang zusammen mit dem Vorverstärkerausgang (Nr. 9) kann ein Signalprozessor  
zwischen Mischpult und Verstärker eingeschleift werden.  
22. Bridge In/Out  
Liefert ein Ausgangssignal, das unabhängig von den Master-Pegel-, Low-EQ- und High-EQ-  
Reglern ist. Zudem kann er als Mix-Ausgang verwendet werden, wenn die entsprechende  
Klemme eines anderen Mischpults/Verstärkers an diese Klemme angeschlossen wird. Hier  
kann auch der Ausgang eines externen Tonbandgeräts ohne Beeinflussung durch die EQ-  
und Master-Pegelregler abgenommen werden. Die Eingangsimpedanz der Geräte, die an  
diese Klemme angeschlossen werden, sollte über 10 kOhm betragen.  
23. Program Input  
Ein zusätzlicher Eingang, an den Signale anderer Quellen wie etwa eines weiteren  
Mischpults oder Mischpults/Verstärkers gesendet werden können. Der Signalpegel an  
diesem Eingang wird vom PROGRAM-Pegelregler auf der Vorderseite geregelt und an den  
Mix-Bus gesendet. Der Program-Eingang kann als „Kanal 9" angesehen werden, für den  
jedoch kein PLUG-IN-MODUL verwendet werden kann.  
HINWEIS: Dieser Eingang wird stummgeschaltet, wenn der Mute-1-Bus (Nr. 24) aktiviert  
ist.  
24. Ext Mute 1/2  
Wenn eine dieser Klemmen an die Shield-Klemme (SHD) angeschlossen wird, wird der jew-  
eilige Mute-Bus aktiviert und das Signal an alle PLUG-IN-MODULE gesendet, die seine  
Stummschaltefunktion verwenden. Nähere Informationen über die Stummschaltefunktion  
des Moduls erfahren Sie aus der Bedienungsanleitung des jeweiligen PLUG-IN-MODULS.  
25. Externe Lautstärkeregler  
Diese Anschlüsse ermöglichen den Einsatz einer externen Master-Lautstärkeregelung  
(Fernregelung). Um die Lautstärke vollständig über die Fernregelung einstellen zu können,  
muss der Master-Lautstärkeregler auf der Vorderseite (Nr. 1) auf die Maximalposition „10"  
gestellt werden. Die Lautstärkefernregelung muss wie in Abbildung 1 dargestellt  
angeschlossen werden, wobei die im Uhrzeigersinn drehende Klemme an die Abschirmung  
(SHD), die Schleiffeder an den Regler (C) und die im entgegengesetzten Uhrzeigersinn  
drehende Klemme an die Spannung (V) angeschlossen werden müssen. Bei Einsatz eines  
linearen Potentiometers mit 10 kOhm wird eine Dämpfung von etwa 30 dB erzielt, während  
bei einem Potentiometer mit 100 kOhm eine Dämpfung von etwa 60 dB erzielt wird. Siehe  
Abbildung 1.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation der Rack-Montageösen  
Dieses Gerät kann mit Hilfe der beiden beiliegenden Rack-Ösen in einem genormten EIA-  
Geräte-Rack montiert werden. Zur Befestigung der Ösen brauchen Sie einfach nur die drei  
Schrauben zu entfernen, die sich vorne an beiden Seiten des Gerätes befinden, und die Ösen  
an den jeweiligen Montageöffnungen auszurichten. Für die Montage im Rack können die  
Gummifüße an der Unterseite des Gerätes bei Bedarf entfernt werden.  
Hinweis: Um eine ausreichende Belüftung zu gewährleisten, muss mindestens eine Rack-  
Höhe zwischen den Geräten frei bleiben, wenn mehrere Verstärker in demselben Rack mon-  
tiert werden. Um einen korrekten Betrieb des Gerätes zu gewährleisten, muss ein Abstand  
von mindestens 16 cm zu Wänden oder brennbaren Flächen eingehalten werden.  
Figure 2  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Es stehen acht EINGANGSANSCHLÜSSE für PLUG-IN-MODULE zur Verfügung. Wählen Sie für den  
jeweiligen Anwendungszweck das geeignete Modul aus. Stecken Sie das bzw. die Module in die  
EINGANGSANSCHLÜSSE. Schieben Sie sie zwischen die Kontaktführungsschienen ein, und befes-  
Eingangsanschlüsse  
(siehe Abbildung 3)  
tigen Sie sie mit den beiliegenden Schrauben  
. Achten Sie darauf, dass die  
Schrauben fest angezogen sind, sodass sie korrekt geerdet sind. Nähere Informationen zu den  
Anschlüssen erfahren Sie aus der Bedienungsanleitung des jeweiligen PLUG-IN-MODULS.  
ACHTUNG:  
PLUG-IN-MODULE dürfen nicht eingesteckt oder herausgezogen werden, solange der  
Mischpult/Verstärker eingeschaltet ist. Schließen Sie die nicht belegten EINGANGSANSCHLÜSSE mit  
den beiliegenden Blenden, und schrauben Sie diese fest.  
Figure 3  
Anschlüsse der Lautsprecherausgänge  
Die Lautsprecherausgänge des Mischpults/Verstärkers sind für 4 Ohm, 8 Ohm, 25 V und 70 V ausgelegt.  
Schließen Sie das Lautsprechersystem an EINEN dieser Ausgänge an. Es kann Verdrahtung Klasse 2  
verwendet werden.  
MMA81502 (120 V)  
Es gibt zwei Arten von Ausgängen:  
Direkter Ausgang, 4 Ohm,  
8 Ohm, 25 V und 70 V über Output Transformer.  
TFür beide ist ein unterschiedliches Anschlussverfahren erforderlich (siehe Abbildung 4). Wenn die  
trafoisolierten Ausgänge verwendet werden, muss der Low-Cut-Schalter auf ON stehen.  
Hinweis: Die in Abbildung 4 aufgeführten Impedanzwerte geben die Gesamtimpedanz des  
Lautsprechersystems (Last) an.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Die Lautsprecherausgänge des Mischpults/Verstärkers sind für 4 Ohm, 8 Ohm, 70 V und 100 V ausgelegt.  
Schließen Sie das Lautsprechersystem an EINEN dieser Ausgänge an. Es kann Verdrahtung Klasse 2 ver-  
wendet werden.  
MMA81502 (230 V)  
Es gibt zwei Arten von Ausgängen: Direkter Ausgang, 4 Ohm,  
8 Ohm, 70 V und 100 V über Output Transformer  
Für beide ist ein unterschiedliches Anschlussverfahren erforderlich (siehe Abbildung 5). Wenn die  
trafoisolierten Ausgänge verwendet werden, muss der Low-Cut-Schalter auf ON stehen.  
Hinweis: Die in Abbildung 5 aufgeführten Impedanzwerte geben die Gesamtimpedanz des  
Lautsprechersystems (Last) an.  
Figure 5  
Die Lautsprecherausgänge des Mischpults/Verstärkers sind für 4 Ohm, 8 Ohm, 25 V, 70 V und 100 V aus-  
gelegt. Schließen Sie das Lautsprechersystem an EINEN dieser Ausgänge an. Es kann Verdrahtung Klasse  
2 verwendet werden.  
MMA8752 (120/230V)  
Es gibt zwei Arten von Ausgängen: Direkter Ausgang, 4 Ohm,  
8 Ohm, 70 V und 100 V über Output Transformer  
Für beide ist ein unterschiedliches Anschlussverfahren erforderlich (siehe Abbildung 6). Wenn die  
trafoisolierten Ausgänge verwendet werden, muss der Low-Cut-Schalter auf ON stehen.  
Hinweis: Die in Abbildung 6 aufgeführten Impedanzwerte geben die Gesamtimpedanz des  
Lautsprechersystems (Last) an.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Die Lautsprecherausgänge des Mischpults/Verstärkers sind für 4 Ohm, 8 Ohm, 70 V und 100 V  
ausgelegt. Schließen Sie das Lautsprechersystem an EINEN dieser Ausgänge an. Es kann  
Verdrahtung Klasse 2 verwendet werden.  
MMA8352 (120V)  
Es gibt zwei Arten von Ausgängen:  
Direkter Ausgang, 4 Ohm,  
8 Ohm, 70 V und 100 V über Output Transformer.  
(siehe Abbildung 7)  
Für beide ist ein unterschiedliches Anschlussverfahren erforderlich  
. Wenn  
die trafoisolierten Ausgänge verwendet werden, muss der Low-Cut-Schalter auf ON stehen.  
Hinweis: Die in Abbildung 7 aufgeführten Impedanzwerte geben die Gesamtimpedanz des  
Lautsprechersystems (Last) an.  
Figure 7  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Rated Output Power:  
MMA81502: 150 W  
Rear Panel Features:  
Preamp Output  
MMA8752: 75 W  
MMA8352: 35 W  
Power Amp Input  
Program Input  
Bridge In/Out  
Output Regulation:  
External Mute Terminals  
External Volume Control  
Plug-in Module Ports 1–8  
Loudspeaker Output Terminals  
AC convenience outlet (120V units only)  
Power Switch  
Direct Out: 0.5dB  
Transformer Out: 1.0dB  
Frequency Response:  
Power Amplifier:  
0.5 dB, 20 Hz to 20 kHz, Direct Out  
1.0 dB, 50 Hz to 20 kHz, Transformer Out  
Preamplifier:  
1.0 dB, 20 Hz to 20 kHz  
Fuse  
IEC Power Connector  
Muting:  
MMA input module with muting capability overrides  
THD:  
the Program Input on Mute 1 bus  
Mute 1 and Mute 2 bus activation with switch  
contact closure via screw terminals  
Power Amplifier: 0.05% (1kHz)  
Preamplifier: 0.10% with nominal gain settings  
Power Bandwidth:  
Power Requirements:  
Direct Out: 10 Hz to 70 kHz  
MMA81502 (120V): 300 Watts, 120 Vac, 60 Hz  
Transformer Out: 30 Hz to 40 kHz  
MMA81502 (230V): 300 Watts, 230 Vac, 50/60 Hz  
MMA8752 (120V): 180 Watts, 120 Vac, 60 Hz  
MMA8752 (230V): 180 Watts, 230 Vac, 50/60 Hz  
MMA8352 (120V): 100 Watts, 120 Vac, 60 Hz  
Signal/ Noise:  
(22 Hz–22 kHz) typical  
All controls CCW: 100 dB  
All controls nom: 95 dB  
Master Level Max: 77 dB  
Dimensions:  
19.00” (W) X 13.25” (D) X 3.45” (H) with rack ears  
and without feet (483 mm X 337 mm X 88 mm)  
17.00” (W) X 13.25” (D) X 4.00” (H) without rack ears  
and with feet (432 mm X 337 mm X 102 mm)  
Outputs:  
Direct Out: 4 Ohms  
Transformer Isolated: 8 Ohms, 25V, 70 V  
(MMA81502, 120V only)  
8 Ohms, 70 V, 100 V (MMA81502, 230V only)  
8 Ohms/25V, 70 V, 100 V (MMA8752)  
8 Ohms, 70 V, 100 V (MMA8352)  
Weight:  
MMA81502: 28.3 lbs. (12.9 kg)  
MMA8752: 25.0 lbs. (11.4 kg)  
MMA8352: 21.1 lbs. (9.6 kg)  
Pre Out: 1 V nom; +21 dBu max at 100 Ohms  
Bridge In/Out: 100 mV at 3.3k Ohms  
Color:  
Black  
Input Sensitivity:  
Program In: 100 mV at 10k Ohms  
Bridge In/Out: 100 mV at 3.3k Ohms  
Power In: 1 Volt at 20k Ohms  
Tone Controls:  
Low EQ: 10 dB at 100 Hz  
High EQ: 10 dB at 10 kHz  
Front Panel Features:  
Channel 1–8 Level Controls  
Program Input Level Control  
High EQ Control  
Low EQ Control  
EQ Bypass Switch  
Master Level Control  
Input Channel Signal Level Indicators (Signal  
Presence: green; Signal Peak: red)  
Mute Bus Status Indicators  
Power Amplifier Signal Presence Indicator  
SPSIndicator  
Power On Indicator  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FRANÇAIS  
MMAMixer/Power Amplifier Systems  
Les MMA81502‚ 8752 et 8352 sont des amplificateurs de hautes qualités destinés aux  
installations professionnelles. D’une grande flexibilité d’utilisation, ces unités représentent le  
‘dernier cri’ en matières de technologies analogiques.  
Description:  
Puissants, simples d’utilisation, les unités de la série MMA délivrent des performances  
incroyables. Avec leur circuiterie faible-bruit et leurs possibilités de connexions, elles sont les  
unités idéales où un amplificateur compact est nécessaire.  
Ce manuel est écrit pour vous donner le plus d’informations possibles sur votre nouveau  
produit Peavey Architectural Acoustics. Nous vous remercions d’avoir choisi Peavey!  
Le meilleur moyen de profiter pleinement de votre nouvelle unité est de comprendre son  
fonctionnement et ses fonctionnalités. Nous espérons que ce manuel ainsi que ceux des  
autres unités Peavey vous procurent ces informations. Nous cherchons constammant à  
améliorer nos produits et modes d’emploi. N’hésitez pas à nous contacter pour des remarques  
ou questions sur ceux-ci ou tout autres renseignements sur nos produits.  
Si vous avez un commentaire à faire sur ce manuel ou proposer des suggestions, écrivez à:  
Peavey Electronics Corp., Architectural Acoustics Division, 711 A St., Meridian, MS 39301.  
Caractéristiques:  
· Mixer 9-canaux amplifié  
· 8 emplacements libres pour l’insertion de module MMA™  
· Entrée dédiée pour signal Program  
· Contrôle d’EQ grave et aigu  
· Filtre désengageable coupe-bas  
· Possibilité de contrôle de volume à distanc  
· 2 bus Mute (mode silence)  
· Sortie préampli et entrée amplificateurs de puissance  
· Protection thermique et contre court-circuit  
· SPS™ (Speaker Protection System, système de protection d’enceintes) avec indicateur  
· Sortie directe 4 Ohm  
· Sorties 8 Ohm‚ 25V et 70V à transformateur isolé (MMA81502, unité 120V seulement)  
· Sorties 8 Ohm‚ 70V et 100V à transformateur isolé (MMA81502, unité 230V seulement)  
· 8 Ohm (25V)‚ 70V et 100V à transformateur isolé (MMA8752)  
· 8 Ohm (25V)‚ 70V et 100V à transformateur isolé (MMA8352)  
· Connecteur d’alimentation pour unité externes (unité 120V seulement)  
· Oreilles de fixation en rack 19" incluses  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
· Salles de présentation  
· Salles de conférence  
· Salles d’attente  
· Systèmes d’appel (Paging)  
· Musique de fond  
· Espaces de vente  
· Restaurants  
Applications  
· Auditoriums  
· Salles de lecture  
· Salles de réunion  
· Centre de convention  
1. Power Indicator  
Cette Led verte s’illumine pour indiquer que votre unité est sous tension  
PANNEAU AVANT  
2. Signal Level Indicator  
Cette Led verte s’illumine lorsqu’un signal est présent aux entrées de votre unité de  
puissance.  
3. SPSIndicator  
Cette Led jaune s’illumine lorsque le SPS s’active (Protection des enceintes). Ce système  
s’active pour prévenir une surcharge en réduisant le gain du signal.  
4. Input Channel Level Controls  
Ce contrôle rotatif vous permet d’ajuster le niveau des signaux d’entrée respectifs dans  
votre mixage.  
5. Input Channel Signal Status Indicators  
Cette Led verte s’illumine lorsqu’un signal est présent à l’entrée du canal correspondant.  
Elle s’illumine en rouge pour vous indiquer que le niveau du signal est trop haut. Prétez  
attention à ne pas saturer le bus du mix!  
6. Program Input Level Control  
Ce contrôle rotatif vous permet d’ajuster le niveau du signal de l’entrée Program.  
7. Low EQ Control (Bass)  
Ce contrôle actif vous permet de varier le niveau des fréquences graves du signal entre  
–10 dB et +10 dB. En le tournant horairement, vous augmentez ce niveau et vice versa.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. High EQ Control (Treble)  
Ce contrôle actif vous permet de varier le niveau des fréquences aigues du signal entre  
–10 dB et +10 dB. En le tournant horairement, vous augmentez ce niveau, et vice versa.  
9. EQ Bypass Switch  
Vous permet d’appliquer/non-appliquer l’équalisation à votre signal. En position sortie,  
l’EQ est active, en position enfoncée, elle est n’est pas appliquée à votre signal.  
10. Mute Bus Indicators  
Ces Leds rouges vous indiquent le statut des bus Mute. En s’illuminant, elles indiquent  
que le bus correspondant est actif.  
11. Master Level Control  
Ce contrôle rotatif permet d’ajuster le volume de sortie de votre unité.  
14  
17  
19  
13  
12  
12  
20  
21  
22  
23  
24  
25  
12. AC Power Receptacle  
PANNEAU ARRIERE  
Ce connecteur est prévu pour recevoir un cable standard IEC (inclu) pour alimenter votre  
appareil.  
Ne déconnecter pas la prise de terre de la prise de votre unité. Si vous rencontrez un  
problème de compatibilité, consultez un électricien pour remplacer la prise.  
13. Power Switch  
Cet interrupteur 2 positions permet de mettre votre unité sous et hors tension.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14. Fuse  
Le fusible se trouve dans le porte fusible situé sur le panneau arrière de votre unité. Si le  
fusible est défectueux, IL DOIT ETRE REMPLACE PAR UN AUTRE DE MEME TYPE ET VALEUR  
POUR EVITER TOUT DOMMAGE A VOTRE UNITE. Si le fusible saute régulièrement, votre  
unité doit être vérifiée par un technicien agréé.  
ATTENTION: Votre unité doit être mise hors tension avant d’envisager de manipuler le  
fusible.  
15. AC Outlet (Unswitched)  
Vous permet d’alimenter d’autres unités auxiliaires dont les besoins n’excèdent  
300Watts. Cette sortie n’est pas affectée par la position de l’interrupteur d’alimentation  
(#13).  
16. Outputs  
Une sortie directe et des sorties à transformateur isolé vous permettent de connecter  
différents systèmes d'enceintes à votre unité. La sortie directe vous permet de connecter  
un système 4-Ohm d'enceintes. Pour utiliser cette sortie, désengager le cavalier entre le  
terminal 4-Ohm du terminal XFMR. Connectez le système d'enceintes entre le terminal 4-  
Ohm et le terminal GND.  
Pour une utilisation d'une sortie à transformateur, vérifier que le cavalier est bien  
connecté entre le terminal de la sortie directe et celui noté XFMR , puis connecter le  
système d'enceintes entre le terminal désignant la sortie voulue (70V, 100V ou 8-Ohm) et  
le terminal COM  
17. Module Input Ports 1–6  
Cet emplacement vous permet d’insérer un module d’entrée MMA™ ne nécessitant pas  
d’alimentation +5V. Pour plus d’informations, consultez le manuel d’utilisation de votre  
module.  
ATTENTION: Les modules ne doivent pas être insérés ou enlevés avec votre unité sous  
tension.  
NOTE: Pas plus de 2 modules OPM(Output Power Modules) ne peuvent être utilisés par  
unité principale.  
18. Module Input Ports 7–8  
Cet emplacement vous permet d’insérer un module d’entrée MMAnécessitant une  
alimentation +5V. Pour plus d’informations, consultez le manuel d’utilisation de votre  
module.  
ATTENTION: Les modules ne doivent pas être insérés ou enlevés avec votre unité sous  
tension.  
NOTE: Pas plus de 2 modules OPM(Output Power Modules) ne peuvent être utilisés par  
unité principale.  
19. Low cut switch  
Ce sélecteur vous permet d’activer un filtre coupe-bas 60Hz.  
20. Preamplifier Out  
Cette sortie vous donne un signal de niveau ligne vous permettant d'alimenter un  
système additionnel d'amplification/enregistrement ou de traiter votre signal par un  
processeur d'effet.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21. Power Amplifier Input  
Cette entrée vous permet d'envoyer un signal ligne 1V directement dans l'ampli de  
puissance de votre unité. Combinée avec la sortie Pré-ampli, un processeur d'effets  
externe peut-être utilisé pour traiter le signal.  
22. Bridge In/Out  
Vous donne un signal de sortie non altéré par les contrôles de volume (Master Level) et  
tonalité (Low et High). Ce signal peut-être envoyé vers tout matériel de mixage ou  
d’enregistrement tant que l’entrée de celui-ci possède une impédance de plus10k Ohms.  
23. Program Input  
Vous permet de connecter à la sortie d’un mixeur ou de toute unité envoyant un signal de  
nivau ligne. Le niveau de ce signal peut être contrôlé par le contrôle PROGRAM LEVEL. On  
pourra considérer cette entrée comme le "Canal 9" de votre unité, dépourvue de la  
capacité d’y connecter un module MMA.  
NOTE: Cette entrée est désactivée (Mute) dès que le bus Mute1 est activé.  
24. Ext Mute 1/2  
Si un de ces connecteurs est relié au terminal de masse (SHD), le bus Mute correspondant  
est activé et transmet l’information aux modules concernés. Référez-vous au manuel  
d’utlisation de vos modules pour d’informations sur leurs capacité à gérer les bus Mute.  
25. External Volume Control  
Ces connections permettent de contrôler le volume de votre unité à distance. Pour une  
amplitude maximum, il est impératif que le potentiomètre de volume de la face avant soit  
en position maximum (position "10"). Le controleur doit être connecté comme montré à la  
Fig. 1, avec le connecteur 'horaire' sur le blindage (SHD); le pointeau sur le Contrôle C); et  
le 'contre-horaire' sur le Voltage (V). En utilisant un potentiomètre de 10 k Ohm, vous  
obtiendrez une atténuation d'à peu près 30dB. En utilisant un 100 k Ohm, celle-ci sera de  
l'ordre de 60 dB.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing Rack-mount Ears  
Votre unité peut-être rackée grâce aux oreilles de fixation (fournies). Pour les assembler sur votre  
unité, simplement dévissez les 3 vis de chaque côté de celle-ci, positionner les oreilles puis reserrer  
les vis en position. Vous pouvez positionner les oreilles de différentes facons afin d'obtenir  
plusieurs sens de fixation pour votre unité. Référez-vous aux figures ci-dessous pour de plus amples  
informations.  
Note: Afin de permettre une ventilation suffisante, laisser au moins un espace libre entre vos unités.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Votre unité est équipée de 8 ports d’entrées pour des modules MMA. Sélectionner les modules  
nécessaires en fonction de l’application. Branchez les modules, positionnez-les suivants les  
Input Connections  
(Figure 3  
guides de métal puis fixez-les en place grace aux vis fournies  
). Assurez-vous que les  
vis soient proprement serrés pour le contact de masse. Pour plus de détails sur les connexions  
de vos modules , reportez-vous à leurs manuels respectifs.  
ATTENTION: Les modules ne devraient jamais être insérés ou enlevés avant de mettre l’unité  
hors-tension. Couvrez les ports non utilisés grace au paneaux appropriés fournis.  
Figure 3  
Loudspeaker Output Connections  
Les sorties enceintes de votre unité sont 4 Ohms, 8 Ohms, 25V et 70V. Connectez la charge d’enceinte à  
UNE SEULE de ces sorties. On pourra utiliser du cable Class2.  
MMA81502 (120V)  
Il existe deux types de sorties:  
4 Ohm / Sortie directe ;  
8 Ohm, 25V, and 70V via Output Transformer  
Les connexions dans chaque cas sont différentes. Reportez-vous à la Figure 4. Si vous utilisez une sortie à  
transformateur, assurez-vous que le filtre coupe-bas est engagé.  
Note: Les valeurs d’impedance de la Figure 4 indique la charge totale du système d’enceinte(s).  
Figure 4  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Les sorties enceintes de votre unité sont 4 Ohms, 8 Ohms, 25V et 70V. Connectez la charge d’enceinte à  
UNE SEULE de ces sorties. On pourra utiliser du cable Class2.  
MMA81502 (230V)  
Il existe deux types de sorties:  
4 Ohm / Sortie directe ;  
8 Ohm, 25V, and 70V via Output Transformer  
Les connexions dans chaque cas sont différentes. Reportez-vous à la Figure 5. Si vous utilisez une sortie à  
transformateur, assurez-vous que le filtre coupe-bas est engagé.  
Note: Les valeurs d’impedance de la Figure 4 indique la charge totale du système d’enceinte(s).  
Figure 5  
Les sorties enceintes de votre unité sont 4 Ohms, 8 Ohms, 25V et 70V. Connectez la charge d’enceinte à UNE SEULE  
de ces sorties. On pourra utiliser du cable Class2.  
MMA8752 (120/230V)  
Il existe deux types de sorties:  
4 Ohm / Sortie directe ;  
8 Ohm, 25V, and 70V via Output Transformer  
Les connexions dans chaque cas sont différentes. Reportez-vous à la Figure 6. Si vous utilisez une sortie à  
transformateur, assurez-vous que le filtre coupe-bas est engagé.  
Note: Les valeurs d’impedance de la Figure 6 indique la charge totale du système d’enceinte(s).  
Figure 6  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Les sorties enceintes de votre unité sont 4 Ohms, 8 Ohms, 25V et 70V. Connectez la charge d’enceinte à  
UNE SEULE de ces sorties. On pourra utiliser du cable Class2.  
MMA8352 (120V)  
Il existe deux types de sorties:  
4 Ohm / Sortie directe ;  
8 Ohm, 25V, and 70V via Output Transformer  
Les connexions dans chaque cas sont différentes. Reportez-vous à la Figure 7 Si vous utilisez une sortie à  
transformateur, assurez-vous que le filtre coupe-bas est engagé.  
Note: Les valeurs d’impedance de la Figure 7 indique la charge totale du système d’enceinte(s).  
Figure 7  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ESPAÑOL  
MMAMixer/Power Amplifier Systems  
Description:  
Las MMA81502‚ 8752 y 8352 son mezcladoras/amplificadores de alta calidad de grado  
industrial. Han sido diseñadas para ofrecer flexibilidad en aplicaciones y representan lo último  
en tecnología en diseño de mezcladoras/amplificadores. Potente pero fácil de usar, la serie  
MMA ofrece calidad de sonido increíble. Su diseño de bajo ruido y funciones aplicables al  
“mundo real” hacen estas unidades ideales para aplicaciones de audio donde se necesita una  
consola/amplificador compacta con múltiples entradas y salidas.  
Este manual ha sido escrito para proveer la mayor cantidad de información posible para su  
nuevo producto Peavey Architectural Acoustics. Es nuestro sincero deseo que disfrute usando  
este producto.  
Sentimos que la mejor forma de disfrutar una copra es teniendo un conocimiento detallado de  
sus funciones, y características de ejecución. Esperamos que este manual, así como los  
manuales de otros productos, provean esto. Si requiere información adicional, por favor  
háganoslo saber. Continuamente estamos buscando formas para proveer información sobre  
nuestros productos y sus sugerencias siempre son bienvenidas y apreciadas.  
Si tiene un comentario sobre este manual o le gustaría hacer una sugerencia, por favor escriba  
a: Peavey Electronics Corp.‚ Architectural Acoustics Division‚ 711 A Street‚ Meridian MS 39301  
Acoustics.  
Caracteristicas:  
· Sistema de mezcladora/amplificador de nueve canales  
· Ocho puertos de entrada aceptan módulos Plug-in MMA™  
· Entradas dedicadas de programa  
· Controles de ecualización grave y aguda  
· Filtro de graves seleccionable  
· Capacidad de volumen externo  
· Dos buses de muteo  
· Capacidad de conexiones de salida del preamp/entrada al amp  
· Protección térmica y de cortos circuitos  
· Sistema de protección de parlantes SPS(Speaker Protection Sistem) con indicador  
· Salida directa de 4 Ohmios  
· Salidas de transformador aislado de 8 Ohmios, 25 Voltios y 70 Voltios (MMA81502 de 120V  
solamente)  
· Salidas de transformador aislado de 8 Ohmios, 70 Voltios y 100 Voltios (MMA81502 de 230V  
solamente)  
· Salidas de transformador aislado de 8 Ohmios, 70 Voltios y 100 Voltios (MMA8352)  
· Salida de conveniencia de CA (unidades de 120V solamente)  
· Instalación de rack opcional con orejas incluidas.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
· Cuartos de presentación  
· Cuartos de juntas  
· Cortes  
· Sistemas de voceo  
· Música ambiental  
· Tiendas  
Applications  
· Auditorios  
· Restaurantes  
· Salas de lectura  
· Salones de funciones  
· Centros de convenciones  
1. Indicador de Corriente  
PANEL FRONTAL  
Este LED verde indica cuando la unidad está recibiendo corriente CA y el interruptor de corriente  
está encendido.  
2. Indicador de Nivel de Señal  
Este LED verde indica la presencia de señal a la salida del amplificador.  
3. Indicador SPS™  
El LED rojo indica cuando los circuitos SPS están activos. El SPS elimina la saturación del  
amplificador.  
4. Controles de Nivel de Canales de Entrada  
Controlan el nivel de la señal de los canales de entrada 1-8 respectivamente al bus de mezcla.  
5. Indicadores de Estatus de Señal en Canales de Entrada  
Indican la presencia de señal (verde) y picos de nivel (rojo) de la señal de entrada al canal antes de  
los controles de nivel. Tener cuidado de no saturar el bus de mezcla.  
6. Control de Nivel de Entrada de Programa  
Controla el nivel de señal del programa de entrada al bus de mezcla.  
7. Control de Ecualización Grave (Bajos)  
Este es un control de ecualización activo que ajusta las frecuencias graves. La rotación en dirección  
de las manecillas del reloj incrementa las frecuencias graves y la rotación en dirección contraria  
provee un recorte en las frecuencias graves ( 10 dB). El ecualizador está en posición plana en el  
centro marcado.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Control de Ecualización Aguda (Altos)  
Este es un control de ecualización activo que ajusta las frecuencias agudas. La rotación en dirección  
de las manecillas del reloj incrementa las frecuencias agudas y la rotación en dirección contraria  
provee un recorte en las frecuencias agudas ( 10 dB). El ecualizador está en posición plana en el  
centro marcado.  
9. Interruptor de Bypass del Ecualizador  
Selecciona el estatus del ecualizador. Cuando está fuera el ecualizador está activo. Cuando está  
dentro los controles del ecualizador están desactivados y la ecualización es plana.  
10. Indicadores de Mute del Bus  
Los LEDs rojos indican el estatus de cada bus de mute. Cada LED se enciende cuado su  
respetivo bus de mute es activado.  
11. Control Maestro de Nivel  
Controla el volumen general del sistema.  
14  
17  
19  
13  
12  
12  
20  
21  
22  
23  
24  
25  
12. Receptáculo de Corriente CA  
PANEL TRASERO  
Este receptáculo es para el cable de corriente IEC (incluido), que provee corriente CA a la  
unidad. Nunca se debe romper la aguja de tierra de ningún equipo. Esta ha sido incluida  
para su seguridad. Si la salida de corriente no tiene entrada para la aguja de tierra, se  
debe conseguir un adaptador de tierra y el tercer cable debe ser aterrizado propiamente.  
Para prevenir el riesgo de una descarga eléctrica y riesgo de incendio, siempre se debe  
aterrizar la consola y el resto del equipo propiamente.  
13. Interruptor de Encendido  
Este interruptor aplica corriente a la unidad.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14. Fusible  
El fusible está localizado en la tapa del orificio del fusible. Si el fusible falla, EL FUSIBLE DEBE  
SER REEMPLAZADO CON UNO DE LAS MISMAS CARATERÍSTICAS PARA PREVENIR DAÑOS AL  
EQUIPO Y PARA PREVENIR LA CANCELACIN DE LA GARANTÍA. Si el amplificador vuela fusibles  
repetidamente, debe ser llevada a un centro de servicio calificado para que sea reparada.  
CUIDADO: El fusible sólo debe ser reemplazado cuando el cable de corriente ha sido  
desconectado de la fuente de energía.  
15. Salida CA (Sin Interruptor)  
Provee corriente CA para equipo auxiliar con requerimientos de corriente de menos de 300  
watts. Esta salida no es controlada por el interruptor de corriente (#13)  
16. Salidas  
Se proveen salidas directas y salidas de transformador aislado para permitir conexiones entre  
el amplificador y sistemas de parlantes. La salida directa permite la conexión a un sistema de  
parlantes de 4 Ohmios. Para usar esta salida, se debe quitar la conexión entre la terminal de 4  
Ohimos y la terminal XMF LINK. Luego, se conecta el sistema de parlantes a la salida de 4  
Ohmios y terminales de tierra (GND).  
Para salidas de transformador aisladas, hay que verificar que la conexión entre la terminal  
XMF LINK y la terminal de 4 Ohmios esté insertada, luego conéctese la carga entre la salida  
deseada y COM. El Interruptor de recorte de graves (#19) debe estar en posición encendida  
(ON). Ver CONEXIONES DE SALIDA DE PARLANTES más adelante para mayor información.  
17. Puertos de Entrada de Módulos 1-6  
Acepta módulos opcionales Plug-in. Los módulos deben ser seleccionados en base a las  
necesidades de instalación. Estos puertos aceptan y soportan módulos Plug-in que no  
requieran corriente de +5V. Para más detalles, hay que verificar con el manual del plug-in  
específico.  
CUIDADO: Los Módulos Plug-in no deben ser insertados o quitados cuando la  
mezcladora/amplificador esté encendida.  
NOTA: No se pueden usar más de dos módulos POM(Output Power Modules) en cada MMA.  
18. Puertos de Entrada de Módulos 7-8  
Acepta módulos opcionales Plug-in. Los módulos deben ser seleccionados en base a las  
necesidades de instalación. Estos puertos sí aceptan y soportan módulos Plug-in que  
requieran corriente de +5V. Para más detalles, hay que verificar con el manual del plug-in  
específico.  
CUIDADO: Los Módulos Plug-in no deben ser insertados o quitados cuando la  
mezcladora/amplificador esté encendida.  
NOTA: No se pueden usar más de dos módulos POM(Output Power Modules) en cada MMA.  
19. Interruptor de Filtros Graves  
Provee un filtro de 6 dB por octava a partir de 60 Hz. Debe ser usado cuando las salidas de  
transformador aisladas estén conectadas al sistema de parlantes.  
20. Salida de Preamplificador  
Provee una salida de nivel de línea de la salida de mezcla maestra para alimentar equipos  
externos como procesadores de señal, sistemas de audición o equipos de grabación. La  
impedancia de entrada del equipo debe ser mayor a 600 Ohmios.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21. Entrada del Amplificador de Poder  
Provee una entrada directa al amplificador con una sensibilidad de entrada de 1 Voltio. Cuando  
se inserta un conectador RCA phono en esta entrada, la conexión entre la salida del preamp y  
el amplificador de poder es desconectada internamente permitiendo acceso directo al  
amplificador. Usar esta entrada a la vez que la salida del preamplificador (#9), un procesador  
de señal puede ser insertado entre la mezcladora y el amplificador.  
22. Puente Dentro/Fuera  
Provee una señal de salida que es independiente de los controles de Nivel Maestro,  
Ecualizadores Grave y Agudo. También puede ser usado como punto de salida de mezcla  
cuando una terminal similar de otra mezcladora/amplificador es conectada a esta terminal.  
Una salida separada para grabadora de cinta puede ser sacada de este punto sin interacción  
con los controles de Ecualización y Nivel Maestro. La impedancia de entrada del equipo  
conectado a esta terminal debe ser mayor a 10k Ohmios.  
23. Entrada de Programa  
Provee una entrada auxiliar que acepta señales de otras fuentes como otra mezcladora o  
mezcladora/amplificador. El nivel de señal en esta entrada es controlado por el control de nivel  
de PROGRAMA en el panel frontal y alimenta al bus de mezcla. La entrada de programa puede  
ser vista como el “canal 9” sin capacidad de aceptación de un módulo plug-in.  
NOTA: Esta entrada es muteada cuando se activa el bus de muteo 1 (#24)  
24. Ext Mute 1/2  
Cuando cualquiera de estas terminales es conectada a la terminal cubierta (shield) (SHD), el  
bus de muteo respectivo es activado y alimenta a los MÓDLUOS PLUG-IN usando su función de  
muteo. Para detalles sobre las funciones de muteo de los módulos, ver el manual del MÓDULO  
PLUG-IN.  
25. Control de Volumen Externo  
Estas conexiones permiten el uso de un control (remoto) maestro de volumen. Para control  
completo del volumen por medio de un control remoto, el Nivel Maestro del panel frontal (#1)  
debe estar en su posición máxima (10). El control de volumen remoto debe ser conectado como  
se muestra en la figura 1, con la terminal de dirección de manecillas del reloj conectada al  
shield (SHD), el wiper conectado al Control (C) y la terminal contra reloj conectada al voltaje  
(V). Usar un potenciómetro de 10k lineal proveerá aproximadamente 30 dB de atenuación,  
mientras que usar un potenciómetro lineal de 100k proveerá aproximadamente 60dB de  
atenuación. Ver figura 1.  
Figure 1  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instalación de orejas para rack  
Esta unidad puede ser montada en un rack estándar EIA con las dos orejas incluidas. Para instalar  
las orejas, simplemente hay que quitar los tres tornillos en el frente de cada lado de la unidad y  
alinear las orejas con los orificios de montura. Puede ser recomendable quitar las patas de hule de  
la parte inferior de la unidad cuando se monta en un rack.  
Nota:  
Para proveer ventilación adecuada, se debe dejar por lo menos un espacio de rack entre  
unidades cuando se usen múltiples amplificadores en el mismo rack. Para operación correcta de  
esta unidad, no se ponga a menos de 6" de la pared o de cualquier sustancia combustible.  
Figure 2  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hay ocho PUERTOS DE ENTRADA para MÓDULOS PULG-IN. Se deben seleccionar los módulos apropiados  
para cada aplicación. Conecta los módulos en los PUERTOS DE ENTRADA. Estos se resbalan a su posición y  
luego deben ser asegurados con sus respectivos tornillos como se muestra en la figura 3. Hay que verificar  
que los tornillos estén lo suficientemente ajustados para que se aterricen propiamente. Para detalles de  
conexión, por favor leer los instructivos de cada MÓDULO PLUG-IN.  
Conexiones de Entrada  
CUIDADO: Los Módulos Plug-in no deben ser insertados o quitados mientras la mezcladora/amplificador  
esté encendida. Los PUERTOS DE ENTRADA que no sean utilizados deben ser cubiertos con sus respectivos  
paneles protectores y asegurados con tornillos.  
Figure 3  
Conexiones de Parlantes  
Las salidas para parlantes de la mezcladora/amplificador son de 4 Ohmios, 8 Ohmios, 25V y  
70V. El sistema de parlantes debe ser conectado solamente a una de estas salidas. Se puede  
usar cableado de clase 2.  
MMA81502 (120V)  
Hay dos tipos de salida:  
Salida Directa de 4 Ohmios  
Salida de Transformador de 8 Ohmios, 25V y 70 V  
El método de conexión difiere en cada caso. Ver la Figura 4. Si se usan las salidas de  
transformador aislado, hay que asegurarse que el filtro de graves está encendido.  
Nota: Los valores de impedancia mostrados en la Figura 4 indican carga total de impedancia del sistema.  
Figure 4  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Las salidas para parlantes de la mezcladora/amplificador son de 4 ohmios, 8 Ohmios, 70V y  
El sistema de parlantes debe ser conectado solamente a una de estas salidas.  
MMA81502 (230V)  
100V.  
Se puede  
usar cableado de clase 2.  
Hay dos tipos de salida:  
Salida Directa de 4 Ohmios  
Salida de Transformador de 8 Ohmios, 25V y 70 V  
Nota: Los valores de impedancia mostrados en la Figura 5 indican carga total de impedancia del sistema.  
Figure 5  
Las salidas para parlantes de la mezcladora/amplificador son de 4 ohmios, 8 Ohmios, 25V, 70V  
y 100V. El sistema de parlantes debe ser conectado a cualquiera de estas salidas. Se puede  
usar cableado de clase 2.  
MMA8752 (120/230V)  
Hay dos tipos de salida:  
Salida Directa de 4 Ohmios  
Salida de Transformador de 8 Ohmios, 25V, 70 V y 100V  
Transformador  
El método de conexión difiere en cada caso. Ver la Figura 6. Si se usan las salidas de  
transformador aislado, hay que asegurarse que el filtro de graves está encendido.  
Nota: Los valores de impedancia mostrados en la Figura 6 indican carga total de impedancia  
del sistema.  
Figure 6  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Las salidas para parlantes de la mezcladora/amplificador son de 4 ohmios, 8 Ohmios, 70V y  
100V. El sistema de parlantes debe ser conectado solamente a una de estas salidas. Se puede  
usar cableado de clase 2.  
MMA8352 (120V)  
Hay dos tipos de salida:  
Salida Directa de 4 Ohmios  
Salida de Transformador de 8 Ohmios, 70V y 100 V  
Figura 7  
El método de conexión difiere en cada caso. Ver la  
. Si se usan las salidas de  
transformador aislado, hay que asegurarse que el filtro de graves está encendido.  
Nota: Los valores de impedancia mostrados en la Figura 7 indican carga total de impedancia  
del sistema.  
Figure 7  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Rated Output Power:  
MMA81502: 150 W  
Rear Panel Features:  
Preamp Output  
MMA8752: 75 W  
MMA8352: 35 W  
Power Amp Input  
Program Input  
Bridge In/Out  
Output Regulation:  
External Mute Terminals  
External Volume Control  
Plug-in Module Ports 1–8  
Loudspeaker Output Terminals  
AC convenience outlet (120V units only)  
Power Switch  
Direct Out: 0.5dB  
Transformer Out: 1.0dB  
Frequency Response:  
Power Amplifier:  
0.5 dB, 20 Hz to 20 kHz, Direct Out  
1.0 dB, 50 Hz to 20 kHz, Transformer Out  
Preamplifier:  
1.0 dB, 20 Hz to 20 kHz  
Fuse  
IEC Power Connector  
Muting:  
MMA input module with muting capability overrides  
THD:  
the Program Input on Mute 1 bus  
Mute 1 and Mute 2 bus activation with switch  
contact closure via screw terminals  
Power Amplifier: 0.05% (1kHz)  
Preamplifier: 0.10% with nominal gain settings  
Power Bandwidth:  
Power Requirements:  
Direct Out: 10 Hz to 70 kHz  
MMA81502 (120V): 300 Watts, 120 Vac, 60 Hz  
Transformer Out: 30 Hz to 40 kHz  
MMA81502 (230V): 300 Watts, 230 Vac, 50/60 Hz  
MMA8752 (120V): 180 Watts, 120 Vac, 60 Hz  
MMA8752 (230V): 180 Watts, 230 Vac, 50/60 Hz  
MMA8352 (120V): 100 Watts, 120 Vac, 60 Hz  
Signal/ Noise:  
(22 Hz–22 kHz) typical  
All controls CCW: 100 dB  
All controls nom: 95 dB  
Master Level Max: 77 dB  
Dimensions:  
19.00” (W) X 13.25” (D) X 3.45” (H) with rack ears  
and without feet (483 mm X 337 mm X 88 mm)  
17.00” (W) X 13.25” (D) X 4.00” (H) without rack ears  
and with feet (432 mm X 337 mm X 102 mm)  
Outputs:  
Direct Out: 4 Ohms  
Transformer Isolated: 8 Ohms, 25V, 70 V  
(MMA81502, 120V only)  
8 Ohms, 70 V, 100 V (MMA81502, 230V only)  
8 Ohms/25V, 70 V, 100 V (MMA8752)  
8 Ohms, 70 V, 100 V (MMA8352)  
Weight:  
MMA81502: 28.3 lbs. (12.9 kg)  
MMA8752: 25.0 lbs. (11.4 kg)  
MMA8352: 21.1 lbs. (9.6 kg)  
Pre Out: 1 V nom; +21 dBu max at 100 Ohms  
Bridge In/Out: 100 mV at 3.3k Ohms  
Color:  
Black  
Input Sensitivity:  
Program In: 100 mV at 10k Ohms  
Bridge In/Out: 100 mV at 3.3k Ohms  
Power In: 1 Volt at 20k Ohms  
Tone Controls:  
Low EQ: 10 dB at 100 Hz  
High EQ: 10 dB at 10 kHz  
Front Panel Features:  
Channel 1–8 Level Controls  
Program Input Level Control  
High EQ Control  
Low EQ Control  
EQ Bypass Switch  
Master Level Control  
Input Channel Signal Level Indicators (Signal  
Presence: green; Signal Peak: red)  
Mute Bus Status Indicators  
Power Amplifier Signal Presence Indicator  
SPSIndicator  
Power On Indicator  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Architectural Acoustics®  
PEAVEY ELECTRONICS CORPORATION LIMITED WARRANTY  
Effective Date: July 1, 1998  
What This Warranty Covers  
Your Peavey Warranty covers defects in material and workmanship in Peavey products purchased and serviced in the U.S.A. and  
Canada.  
What This Warranty Does Not Cover  
The Warranty does not cover: (1) damage caused by accident, misuse, abuse, improper installation or operation, rental, product  
modification or neglect; (2) damage occurring during shipment; (3) damage caused by repair or service performed by persons  
not authorized by Peavey; (4) products on which the serial number has been altered, defaced or removed; (5) products not pur-  
chased from an Authorized Peavey Dealer.  
Who This Warranty Protects  
This Warranty protects only the original retail purchaser of the product.  
How Long This Warranty Lasts  
The Warranty begins on the date of purchase by the original retail purchaser. The duration of the Warranty is as follows:  
Product Category  
Duration  
MediaMatrix® DPU (Excluding Frames), Cinema Processors,  
Power Amplifiers, Pre-Amplifiers, Mixers,  
Electronic Crossovers and Equalizers  
5 years  
5 years  
2 years  
1 year  
Loudspeakers  
Microphones  
Frames  
Speaker Components (incl. speakers, baskets, drivers,  
diaphragm replacement kits and passive crossovers)  
and all Accessories  
1 year  
What Peavey Will Do  
We will repair or replace (at Peavey's discretion) products covered by warranty at no charge for labor or materials. If the prod-  
uct or component must be shipped to Peavey for warranty service, the consumer must pay initial shipping charges. If the  
repairs are covered by warranty, Peavey will pay the return shipping charges.  
How To Get Warranty Service  
(1) Take the defective item and your sales receipt or other proof of date of purchase to your Authorized Peavey Dealer or  
Authorized Peavey Service Center.  
OR  
(2) Ship the defective item, prepaid, to Peavey Electronics Corporation, International Service Center, 412 Highway 11 & 80 East,  
Meridian, MS 39301 or Peavey Canada Ltd., 95 Shields Court, Markham, Ontario, Canada L3R 9T5. Include a detailed descrip-  
tion of the problem, together with a copy of your sales receipt or other proof of date of purchase as evidence of warranty cover-  
age. Also provide a complete return address.  
OR  
(3) All MediaMatrix® Frames needing repair, should be shipped prepaid to Peavey Electronics Corporation, International Service  
Center, 412 Highway 11 & 80 East, Meridian, MS 39301  
Limitation of Implied Warranties  
ANY IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE  
LIMITED IN DURATION TO THE LENGTH OF THIS WARRANTY.  
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.  
Exclusions of Damages  
PEAVEY'S LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE PRODUCT, AT  
PEAVEY'S OPTION. IF WE ELECT TO REPLACE THE PRODUCT, THE REPLACEMENT MAY BE A RECONDITIONED UNIT. PEAVEY  
SHALL NOT BE LIABLE FOR DAMAGES BASED ON INCONVENIENCE, LOSS OF USE, LOST PROFITS, LOST SAVINGS, DAMAGE TO  
ANY OTHER EQUIPMENT OR OTHER ITEMS AT THE SITE OF USE, OR ANY OTHER DAMAGES WHETHER INCIDENTAL, CONSEQUEN-  
TIAL OR OTHERWISE, EVEN IF PEAVEY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclu-  
sion may not apply to you.  
This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  
If you have any questions about this warranty or service received or if you need assistance in locating an Authorized Service  
Center, please contact the Peavey International Service Center at (601) 483-5365 / Peavey Canada Ltd. at (905) 475-2578.  
Features and specifications subject to change without notice.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
80304722  
Peavey Electronics Corporation • 711 A Street • Meridian, MS 39301  
©2002  
Printed in the U.S.A. 10/02  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Musical Instrument Amplifier Series 60 60 User Manual
Peavey Stereo Amplifier CS 800S User Manual
Pioneer Speaker System AVIC N4 User Manual
Planet Technology Switch GSD 503 User Manual
POSIFLEX Business Machines Printer Posiflex Thermal Printer User Manual
Poulan Lawn Mower Pro 925 ZX Pro 950 ZX User Manual
Pride Mobility Mobility Aid SC40X User Manual
Profile Stereo Amplifier 400MSX User Manual
PVI Industries Water Heater PV 6382 07 User Manual
PYLE Audio Heart Rate Monitor PHRM20 User Manual