Peavey Speaker ILS 1294V User Manual

S P E C I F I C A T I O N S  
ILS1294V  
Frequency Response, 1 Meter  
On-axis, Swept-sine in Anechoic  
Environment:  
Low Frequency Section:  
97.0 dB SPL, (2.83 V input)  
High Frequency Section:  
107.0 dB SPL, (2.83 V input)  
Directivity Factor, Q (Mean):  
11.39 5.93  
Directivity Index, Di (Mean):  
63 Hz - 18.5 kHz ( 3 dB)  
9.90 dB 2.53 dB  
Maximum Sound Pressure Level  
(1 meter):  
Full Range:  
Usable Low Frequency Limit  
(-10 dB point):  
Transducer Complement:  
Low Frequency Section:  
1x 12 in. woofer, vented  
48 Hz  
124.8 dB SPL continuous  
130.8 dB SPL peak  
1208-8 SPS  
Power Handling:  
Full Range:  
High Frequency Section:  
1x 1.6 in. exit/100 mm voice coil  
compression driver on Quadratic  
Throat Waveguide44XT™  
(w/o adapter) on CH®-942qt horn  
Low Frequency Section:  
124.0 dB SPL continuous  
130.0 dB SPL peak  
High Frequency Section:  
127.0 dB SPL continuous  
133.0 dB SPL peak  
750 W continuous  
1,500 W program  
3,000 W peak  
Low Frequency Section:  
500 W continuous  
1,000 W program  
2,000 W peak  
High Frequency Section:  
100 W continuous  
200 W program  
Box Tuning Frequency:  
Low Frequency Section: 55 Hz  
Radiation Angle, measured at  
-6 dB point of polar response:  
500 Hz – 1.6 kHz:  
Harmonic Distortion:  
1% rated power  
2nd Harmonic:  
Horiz.  
Vert.  
105o 20o  
130o 35o  
400 W peak  
100 Hz:  
2.18%  
1.6 kHz - 5 kHz:  
1 kHz:  
0.23%  
75o 10o  
65o 15o  
Sound Pressure Level, 1 Watt, at  
1 meter in anechoic environment:  
Full Range:  
Horiz.  
Vert.  
5 kHz - 16 kHz:  
70o 10o  
40o 10o  
96.0 dB SPL, (2.83 V input)  
Horiz.  
Vert.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
• 63 Hz to 18.5 kHz bandpass  
• 4" diaphragm, 1.6" exit, Ferrofluid  
equipped high frequency compression  
driver  
Harmonic Distortion : 10% Rated Power  
120  
110  
100  
90  
• Patented Quadratic Throat Waveguide™  
• Carefully tailored directivity patterns  
• Flexible suspension provisions  
• Robust power handling capabilities  
• Passive crossover included  
• Biamplified crossover provisions  
80  
70  
Applications  
• Stadiums  
60  
• Arenas  
• Multi-purpose facilities  
• Cruise ships  
50  
20  
50  
100  
200  
500  
1k  
2k  
5k  
10k  
20k  
Frequency (Hz)  
2nd Harmonic  
3rd Harmonic  
• Theme parks  
Figure 5  
• Houses of worship  
• Live music venues  
• Hotel meeting rooms  
• Conference facilities  
• Theaters  
• Auditoriums  
• Civic centers  
• Judicial facilities  
• Gymnasiums  
• Performing arts centers  
Description  
The new Peavey ILS 1294V (vertical)  
Loudspeaker System is a two-way,  
vented low frequency enclosure using  
a 12" low frequency driver paired with  
a 90° (horizontal) by 40° (vertical) high  
frequency waveguide. The HF section  
employs a 1.6" exit/100 mm voice coil  
compression driver mounted on one of  
Peavey’s revolutionary new Quadratic  
Throat Waveguides. The ILS 1294 has  
a full range sensitivity of 96 dB SPL –  
(1 Watt/1 meter) and a maximum output  
of 130 dB at 1 meter (full range).  
Harmonic Distortion : 1% Rated Power  
110  
100  
90  
The Peavey ILS 1294 is a high  
performance loudspeaker system for  
use in demanding sound reinforcement  
applications. The robust construction of  
the ILS 1294 provides power handling  
capacities of 750 W continuous, 1.5 kW  
program and 3.0 kW peak (full range).  
The unit may be operated using the  
internal passive crossover or may be  
biamplified. Twelve 3/8" x 16 threaded  
mounting suspension points (3 each top  
and bottom and 2 each sides and back)  
allow a variety of suspension  
80  
70  
60  
50  
40  
20  
50  
100  
200  
500  
1k  
2k  
5k  
10k  
20k  
Frequency (Hz)  
configurations. Multiple units may be  
mounted to form a vertical/horizontal  
2nd Harmonic  
3rd Harmonic  
Figure 6  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
array [see limitations under mounting  
instructions]. Both versions of the ILS  
1294 are solidly constructed of 3/4"  
void free poplar plywood and finished  
with an exterior grade hardened black  
paint.  
in the vertical plane. The outside  
dimensions shall be 27.00 inches high  
by 19.38 inches wide by 17.75 inches  
deep. The weight shall be 70 pounds.  
The loudspeaker system shall be an  
Architectural Acoustics model ILS  
1294V.  
Harmonic Distortion  
Second and third harmonic distortions  
vs. frequency are plotted in figures 5  
and 6 for two power levels, ten  
percent (10%) of rated input power  
and either one percent (1%) of rated  
input power or one Watt, whichever is  
greater. Distortion is read from the  
graph as the difference between the  
fundamental signal (frequency  
response) and the desired harmonic.  
As an example, a distortion curve that  
is down 40 dB from the fundamental  
is equivalent to 1% distortion.  
Frequency Response  
This measurement is useful in  
3 + 2 YEAR LIMITED  
WARRANTY  
determining how accurately a given  
unit reproduces an input signal. The  
frequency response of the ILS 1294V  
is measured at a distance of 1 meter  
using a 1 Watt (into the nominal  
impedance) swept-sine input signal.  
As shown in Figure 1, the selected  
drivers in the ILS 1294V combine to  
give a smooth frequency response  
from 63 Hz — 18.5 kHz.  
NOTE: For details, refer to the  
warranty statement. Copies of  
this statement may be obtained  
by contacting Peavey Electronics  
Corporation, P.O. Box 2898, Meridian,  
Mississippi 39301-2898.  
Mounting  
Caution: Before attempting to  
suspend this speaker, consult a  
certified structural engineer. The  
speaker can fall from improper  
suspension, resulting in serious injury  
and property damage. Other  
enclosures may be suspended below  
one ILS 1294V. However, the  
combined weight of additional  
Directivity  
Beamwidth is derived from the -6 dB  
points from the polar plots (see figure  
3) which are measured in a whole  
space anechoic environment. Q and  
Directivity Index are plotted for the on- enclosures and all cables, clamps and  
axis measurement position. These are other hardware must not exceed 330  
specifications that provide a reference pounds. The ILS 1294V weighs 70  
to the coverage characteristics of the  
pounds and the maximum combined  
unit. These parameters provide insight weight suspended from the uppermost  
for proper placement and installation  
in the chosen environment. The  
mounting bracket assemblies must  
not exceed 400 pounds. The  
blending of the components of the ILS maximum enclosure angle is 45o. Use  
1294V exhibit a desirable beamwidth  
and directivity (Figure 3 and 4)  
suitable for sound reinforcement  
applications.  
only the correct mating hardware. All  
associated rigging is the responsibility  
of others.  
Architectural and Engineering  
Specifications  
Power Handling  
There are many different approaches  
to power handling ratings. Peavey  
rates this loudspeaker system's power  
handling using a full-range form of the  
AES Standard 2-1984. Using audio  
band 20 Hz to 20 kHz pink noise with  
peaks of four times the RMS level,  
this strenuous test signal assures the  
user that every portion of this system  
can withstand today’s high technology  
music. This rating is contingent upon  
having a minimum of 3 dB of amplifier  
headroom available.  
The loudspeaker system shall have  
an operating bandwidth of 63 Hz —  
18.5 kHz. The nominal output level  
shall be 96.0 dB when measured at a  
distance of one meter with an input of  
one Watt. The nominal impedance  
shall be 8.0 Ohms. The maximum  
continuous power handling shall be  
750 Watts, maximum program power  
of 1,500 Watts and a peak power  
input of at least 3,000 Watts, with a  
minimum amplifier headroom of 3 dB.  
The nominal radiation geometry shall  
be 90o in the horizontal plane and 40o  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ILS 1294V  
Horizontal Polar Patterns 6 dB per Division  
0o  
0o  
0o  
30o  
-30o  
30o  
-30o  
30o  
-30o  
60o  
-60o  
60o  
-60o  
60o  
-60o  
90o  
-90o  
90o  
-90o  
90o  
-90o  
200 Hz  
250 Hz  
315 Hz  
0o  
0o  
0o  
30o  
-30o  
30o  
-30o  
30o  
-30o  
60o  
-60o  
60o  
-60o  
60o  
-60o  
90o  
-90o  
90o  
-90o  
90o  
-90o  
500 Hz  
630 Hz  
400 Hz  
0o  
0o  
0o  
30o  
-30o  
30o  
-30o  
30o  
-30o  
60o  
-60o  
60o  
-60o  
60o  
-60o  
90o  
-90o  
90o  
-90o  
90o  
-90o  
800 Hz  
1 kHz  
1.25 kHz  
0o  
0o  
0o  
30o  
-30o  
30o  
-30o  
30o  
-30o  
60o  
-60o  
60o  
-60o  
60o  
-60o  
90o  
-90o  
90o  
-90o  
90o  
-90o  
1.6 kHz  
2 kHz  
2.5 kHz  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ILS 1294V  
Horizontal Polar Patterns 6 dB per Division  
0o  
0o  
0o  
30o  
-30o  
30o  
-30o  
30o  
-30o  
60o  
-60o  
60o  
-60o  
60o  
-60o  
90o  
-90o  
90o  
-90o  
90o  
-90o  
3.15 kHz  
4 kHz  
5 kHz  
0o  
0o  
0o  
30o  
-30o  
30o  
-30o  
30o  
-30o  
60o  
-60o  
60o  
-60o  
60o  
-60o  
90o  
-90o  
90o  
-90o  
90o  
-90o  
8 kHz  
10 kHz  
6.3 kHz  
0o  
0o  
30o  
-30o  
30o  
-30o  
60o  
-60o  
60o  
-60o  
90o  
-90o  
90o  
-90o  
12.5 kHz  
16 kHz  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
ILS 1294V  
Vertical Polar Patterns 6 dB per Division  
90o  
90o  
90o  
60o  
60o  
60o  
30o  
30o  
30o  
0o  
0o  
0o  
-30o  
-30o  
-30o  
-60o  
-60o  
-60o  
-90o  
-90o  
-90o  
200 Hz  
250 Hz  
315 Hz  
90o  
90o  
90o  
60o  
60o  
60o  
30o  
30o  
30o  
0o  
0o  
0o  
-30o  
-30o  
-30o  
-60o  
-60o  
-60o  
-90o  
-90o  
-90o  
500 Hz  
630 Hz  
400 Hz  
90o  
90o  
90o  
60o  
60o  
60o  
30o  
30o  
30o  
0o  
0o  
0o  
-30o  
-30o  
-30o  
-60o  
-60o  
-60o  
-90o  
-90o  
-90o  
800 Hz  
1 kHz  
1.25 kHz  
90o  
90o  
90o  
60o  
60o  
60o  
30o  
30o  
30o  
0o  
0o  
0o  
-30o  
-30o  
-30o  
-60o  
-60o  
-60o  
-90o  
-90o  
-90o  
1.6 kHz  
2 kHz  
2.5 kHz  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ILS 1294V  
Vertical Polar Patterns 6 dB per Division  
90o  
90o  
90o  
60o  
60o  
60o  
30o  
30o  
30o  
0o  
0o  
0o  
-30o  
-30o  
-30o  
-60o  
-60o  
-60o  
-90o  
-90o  
-90o  
3.15 kHz  
4 kHz  
5 kHz  
90o  
90o  
90o  
60o  
60o  
60o  
30o  
30o  
30o  
0o  
0o  
0o  
-30o  
-30o  
-30o  
-60o  
-60o  
-60o  
-90o  
-90o  
-90o  
8 kHz  
10 kHz  
6.3 kHz  
90o  
90o  
60o  
60o  
30o  
30o  
0o  
0o  
-30o  
-30o  
-60o  
-60o  
-90o  
-90o  
12.5 kHz  
16 kHz  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
A
10.723  
2.220  
2.220  
2.220  
17.712  
22.500  
8.704  
10.955  
19.356  
8.283  
A
View A-A  
2.220  
26.940  
9.017  
ILS 1294V  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
ILS1294V INPUT  
TM  
ILS 1294V  
A PRODUCT OF PEAVEY ELECTRONICS CORP.  
FULL RANGE  
1+ & 2+ (+)  
1- & 2- (-)  
BIAMP  
1+: LF+  
1-: LF-  
2+: HF+  
2-: HF-  
ALL CONNECTORS ARE WIRED IN PARALLEL INTERNALLY.  
CHANGE INTERNAL JUMPER FOR BIAMP OR FULL RANGE  
OPERATION.  
1+  
1
-
N.C.  
2+  
2-  
FULL RANGE  
BIAMP  
LF: 500W RMS CONT.  
8 OHMS  
750W RMS CONT.  
8 OHMS  
HF:100W RMS CONT.  
>1.0 kHz  
8 OHMS  
WARNING: CONSULT SPEC SHEET FOR FULL SUSPENSION  
RATINGS. DO NOT EXCEED 400 lbs. OR 45 DEGREE ANGLE  
BUILT UNDER U.S. PATENT NOS.  
6,059,069 AND 6,064,745  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES:  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features and specifications subject to change without notice.  
Peavey Electronics Corporation • 711 A Street • Meridian • MS • 39301  
©2001  
Printed in the U.S.A. 02/01  
80304824  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pentax Camera Flash AF 16 User Manual
Pentax Digital Camera 12161 User Manual
Petsafe Electric Pet Fence PIF 300 User Manual
Philips Cell Phone Se6 User Manual
Philips Universal Remote RC136 17 User Manual
Pioneer Car Stereo System XR P340M User Manual
Pitco Frialator Pasta Maker and RSE14 User Manual
Power Acoustik Car Stereo System Pwm 70 User Manual
Power Acoustik Stereo Equalizer PEQ 72 User Manual
Procom Electric Heater ML200HBA User Manual