Patton electronic Switch 6511RC User Manual

Model 6511RC  
Matrix Switch  
User Manual  
Sales Office: +1 (301) 975-1000  
Technical Support: +1 (301) 975-1007  
WWW: www.patton.com  
Part Number: 07MD6511RC-GS, Rev. B  
Revised: February 20, 2012  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Contents ......................................................................................................................................................... 3  
Compliance Information ................................................................................................................................ 7  
Radio and TV Interference ...............................................................................................................................7  
Industry Canada Notice ....................................................................................................................................7  
FCC Part 68 (ACTA) Statement .......................................................................................................................7  
CE Notice .........................................................................................................................................................8  
About this guide ............................................................................................................................................. 9  
Audience................................................................................................................................................................. 9  
Structure................................................................................................................................................................. 9  
Precautions........................................................................................................................................................... 10  
Typographical conventions used in this document................................................................................................ 10  
General conventions .......................................................................................................................................10  
Mouse conventions .........................................................................................................................................11  
1
Introduction.................................................................................................................................................. 13  
Model 6511RC Matrix Switch overview................................................................................................................14  
Hardware overview................................................................................................................................................16  
ForeFront chassis architectures ........................................................................................................................19  
ForeFront Model 6476 6U cPCI chassis ...................................................................................................19  
The ForeFront Model 6676 9U chassis .....................................................................................................20  
Matrix Switch functionality ............................................................................................................................21  
TDM mapping and aggregation ................................................................................................................21  
TDM bus architecture ...............................................................................................................................22  
STM-1 link architecture ............................................................................................................................22  
Matrix Switch TDM capacity ....................................................................................................................23  
Matrix Switch Ethernet Switching ..................................................................................................................23  
Management ...................................................................................................................................................24  
Management Services ................................................................................................................................24  
Management Interfaces .............................................................................................................................24  
Management Approach .............................................................................................................................24  
Matrix Switch Interfaces .................................................................................................................................25  
WAN Interfaces ........................................................................................................................................25  
Mid-Plane Interfaces .................................................................................................................................25  
LAN Interface ...........................................................................................................................................25  
RS-232 Config port ..................................................................................................................................26  
Power system ..................................................................................................................................................26  
Central processing unit ...................................................................................................................................26  
System timing .................................................................................................................................................26  
Clocking Mode .........................................................................................................................................26  
Clocking Source ........................................................................................................................................26  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Contents  
Model 6511RC User Manual  
Temperature ...................................................................................................................................................27  
Altitude ...........................................................................................................................................................27  
Humidity ........................................................................................................................................................27  
Physical dimensions ........................................................................................................................................27  
LED Indicators ...............................................................................................................................................27  
Approvals ..............................................................................................................................................................29  
2
Hardware installation.................................................................................................................................... 31  
Introduction..........................................................................................................................................................32  
Unpacking the Model 6511RC Matrix Switch ......................................................................................................32  
Verifying that the ForeFront chassis is properly installed .......................................................................................32  
Verfying correct electrical grounding ...............................................................................................................33  
Verifying correct cover plate installation .........................................................................................................33  
Matrix Switch hardware installation ......................................................................................................................34  
Installing the network cables..................................................................................................................................35  
Connecting the front-panel Ethernet LAN port ..............................................................................................36  
Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hub ...............................................36  
Connecting the rear-panel STM-1 WAN port to an SDH network ................................................................37  
Connecting the STM-1 optical interface to fiber-optic network cables ......................................................37  
Connecting the STM-1 electrical interface to coaxial network cables .........................................................38  
Connecting the rear-panel Ethernet WAN/management ports ........................................................................39  
Completing the hardware installation....................................................................................................................40  
3
Configuring the Matrix Switch for operation................................................................................................ 41  
Introduction..........................................................................................................................................................42  
Configuration prerequisites ...................................................................................................................................42  
Initial configuration through the RS-232 control port...........................................................................................43  
Connecting the DB9-RJ45 adapter with the included cable ............................................................................43  
Setting up the HyperTerminal (or similar program) session ............................................................................44  
Using a browser to complete Model 6511RC configuration ..................................................................................47  
Displaying the Matrix Switch 6511RC web administration pages ...................................................................47  
Home page overview .................................................................................................................................49  
Configuring the default gateway .....................................................................................................................51  
Configuring the system clocking parameters ...................................................................................................52  
Module clocking mode ..............................................................................................................................52  
Module clocking source and fallback .........................................................................................................53  
Example 1 ...........................................................................................................................................53  
Example 2 ...........................................................................................................................................54  
Configuring the SDH circuit parameters ........................................................................................................54  
Accessing the SDH circuit parameters .......................................................................................................55  
Configuring the SDH physical interface type ............................................................................................56  
Configuring the SDH interface parameters ...............................................................................................56  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 6511RC User Manual  
Contents  
Configuring the SDH path trace parameters .............................................................................................57  
Configuring DS0 idle codes ............................................................................................................................58  
Accessing the idle code configuration ........................................................................................................59  
Defining the DS0 idle code configuration .................................................................................................60  
Selecting the SDH mapping path ....................................................................................................................60  
Defining DS0 mappings .................................................................................................................................62  
Defining DS0 mappings using E1 port format ..........................................................................................64  
Examples for configuring DS0 mappings. .................................................................................................65  
Defining DS0 mappings using TU format ................................................................................................69  
Examples for configuring DS0 mappings. .................................................................................................72  
Saving your configuration ...............................................................................................................................74  
Backing up your configuration parameters.............................................................................................................75  
Backing up the configuration store in flash memory .......................................................................................76  
Completing the installation ...................................................................................................................................77  
4
5
Operation and shutdown............................................................................................................................... 79  
Introduction..........................................................................................................................................................80  
Activating the Model 6511RC...............................................................................................................................80  
De-activating the Model 6511RC .........................................................................................................................80  
Troubleshooting and maintenance................................................................................................................ 81  
Introduction..........................................................................................................................................................82  
Troubleshooting during initial deployment ...........................................................................................................82  
General fault analysis.............................................................................................................................................83  
Matrix Switch test tools.........................................................................................................................................86  
Loopback test modes for the STM-1 port .......................................................................................................86  
Facility Loop [sonetFacilityLoop(1)] .........................................................................................................87  
Terminal loop [sonetTerminalLoop(2)] ....................................................................................................88  
Other Loop [sonetOtherLoop(3)] .............................................................................................................90  
SDH section trace and path trace ....................................................................................................................90  
Sections and paths .....................................................................................................................................91  
Section trace ..............................................................................................................................................91  
Path trace ..................................................................................................................................................92  
Number of paths per frame .......................................................................................................................93  
Periodic maintenance ............................................................................................................................................94  
Calibration ......................................................................................................................................................94  
Maintenance..........................................................................................................................................................94  
Replacing the Model 6511RC .........................................................................................................................94  
Exporting the current Model 6511RC configuration ................................................................................94  
Removing the defective Model 6511RC ....................................................................................................97  
Installing the replacement Model 6511RC ................................................................................................98  
Importing a saved configuration ................................................................................................................98  
Completing the installation .......................................................................................................................99  
6
Contacting Patton for assistance ................................................................................................................. 101  
Introduction........................................................................................................................................................102  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Model 6511RC User Manual  
Contact information............................................................................................................................................102  
Warranty Service and Returned Merchandise Authorizations (RMAs).................................................................102  
Warranty coverage ........................................................................................................................................102  
Out-of-warranty service ...........................................................................................................................102  
Returns for credit ....................................................................................................................................102  
Return for credit policy ...........................................................................................................................103  
RMA numbers ..............................................................................................................................................103  
Shipping instructions ..............................................................................................................................103  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance Information  
Radio and TV Interference  
The Model 6511RC generates and uses radio frequency energy, and if not installed and used properly—that is,  
in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep-  
tion. The Model 6511RC has been tested and found to comply with the limits for a Class A computing device  
in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide rea-  
sonable protection from such interference in a commercial installation. However, there is no guarantee that  
interference will not occur in a particular installation. If the Model 6511RC causes interference to radio or tele-  
vision reception, which can be determined by disconnecting the cables, try to correct the interference by one or  
more of the following measures: moving the computing equipment away from the receiver, re-orienting the  
receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the comput-  
ing equipment and receiver are on different branches).  
Industry Canada Notice  
Note This equipment meets the applicable Industry Canada Terminal  
Equipment Technical Specifications. This is confirmed by the regis-  
tration number. The abbreviation, IC, before the registration number  
signifies that registration was performed based on a Declaration of  
conformity indicating that Industry Canada technical specifications  
were met. It does not imply that Industry Canada approved the  
equipment.  
Users should not attempt to establish or modify ground connections  
themselves, instead they should contact the appropriate electric  
inspection authority or electrician.  
FCC Part 68 (ACTA) Statement  
This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom  
side of this equipment is a label that contains—among other information—a product identifier in the format  
US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.  
A plug and jack used to connect this equipment to the premises wiring and telephone network must comply  
with the applicable FCC Part 68 rules and requirements adopted by the ACTA.  
This equipment uses a Universal Service Order Code (USOC) jack: RJ-11C.  
If this equipment causes harm to the telephone network, the telephone company will notify you in advance  
that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone  
company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint  
with the FCC if you believe it is necessary.  
The telephone company may make changes in its facilities, equipment, operations or procedures that could  
affect the operation of the equipment. If this happens the telephone company will provide advance notice in  
order for you to make necessary modifications to maintain uninterrupted service.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Compliance Information  
Model 6511RC User Manual  
If trouble is experienced with this equipment, for repair or warranty information, please contact our company.  
If the equipment is causing harm to the telephone network, the telephone company may request that you dis-  
connect the equipment until the problem is resolved.  
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public  
service commission or corporation commission for information.  
In accordance with FCC rules and regulation CFR 47 68.218(b)(6), you must notify the telephone company  
prior to disconnection. The following information may be required when applying to your local telephone  
company for leased line facilities. The Universal Service Order Code (USOC) is RJ48. The Facility Interface  
Codes (FIC) are 04DU9-BN, 04DU9-DN, 04DU9-1KN, and 04DU9-1SN. The Service Order Code (SOC)  
is 6.0N.  
Facility  
Service Network  
Service  
Interface Code Code  
Connection  
1.544 Mbps SF format without line power  
1.544 Mbps SF and B8ZS without line power  
1.544 Mbps ANSI ESF without line power  
1.544 Mbps ANSI ESF and B8ZS without line power  
04DU9-BN  
04DU9-DN  
04DU9-1KN  
04DU9-1SN  
6.0N  
6.0N  
6.0N  
6.0N  
RJ-48C  
RJ-48C  
RJ-48C  
RJ-48C  
CE Notice  
The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromag-  
netic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A  
Certificate of Compliance is available by contacting Technical Support.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
About this guide  
This guide describes installing and configuring a Patton Electronics Model 6511 TDM-Digital Access Con-  
centrator (Matrix Switch). By the time you are finished with this guide, your Matrix Switch will be connected  
to the remote DSL modems and transferring data. The instructions in this guide are based on the following  
assumptions:  
The Matrix Switch is installed in a Patton ForeFront chassis  
The Matrix Switch will connect to an SDH/STM-1 network  
There is a LAN connected to one of the Matrix Switch’s Ethernet ports  
Audience  
This guide is intended for the following users:  
Operators  
Installers  
Maintenance technicians  
Structure  
This guide contains the following chapters and appendices:  
Chapter 1 describes the Matrix Switch  
Chapter 2 describes installing the Matrix Switch hardware  
Chapter 3 describes configuring the Matrix Switch for use  
Chapter 4 details how to power up and deactivate the Matrix Switch  
Chapter 5 contains troubleshooting and maintenance information  
Chapter 6 contains information on contacting Patton technical support for assistance  
For best results, read the contents of this guide before you install the Matrix Switch.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
About this guide  
Model 6511RC User Manual  
Precautions  
Notes and cautions, which have the following meanings, are used throughout this guide to help you become  
aware of potential Matrix Switch problems. Warnings relate to personal injury issues, and Cautions refer to  
potential property damage.  
Note Calls attention to important information.  
The shock hazard symbol and WARNING heading indicate a potential electric  
shock hazard. Strictly follow the warning instructions to avoid injury caused  
by electric shock.  
The alert symbol and WARNING heading indicate a potential safety hazard.  
Strictly follow the warning instructions to avoid personal injury.  
The shock hazard symbol and CAUTION heading indicate a  
potential electric shock hazard. Strictly follow the instructions to  
avoid property damage caused by electric shock.  
The alert symbol and CAUTION heading indicate a potential haz-  
ard. Strictly follow the instructions to avoid property damage.  
Typographical conventions used in this document  
This section describes the typographical conventions and terms used in this guide.  
General conventions  
The procedures described in this manual use the following text conventions:  
Table 1. General conventions  
Convention  
Meaning  
Indicates a cross-reference hyperlink that points to a figure, graphic,  
table, or section heading. Clicking on the hyperlink jumps you to the ref-  
erence. When you have finished reviewing the reference, click on the  
Garamond blue type  
Go to Previous View button  
in the Adobe® Acrobat® Reader  
toolbar to return to your starting point.  
Futura bold type  
Italicized Futura type  
Futura type  
Indicates the names of menu bar options.  
Indicates the names of options on pull-down menus.  
Indicates the names of fields or windows.  
Garamond bold type  
Indicates the names of command buttons that execute an action.  
Angle brackets indicate function and keyboard keys, such as <SHIFT>,  
<CTRL>, <C>, and so on.  
< >  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
About this guide  
Table 1. General conventions (Continued)  
Convention  
Meaning  
Are you ready?  
All system messages and prompts appear in the Courierfont as the  
system would display them.  
% dir *.*  
Bold Courier font indicates where the operator must type a response or  
command  
Mouse conventions  
The following conventions are used when describing mouse actions:  
Table 2. Mouse conventions  
Convention  
Meaning  
Left mouse button  
This button refers to the primary or leftmost mouse button (unless you have  
changed the default configuration).  
Right mouse button This button refers the secondary or rightmost mouse button (unless you have  
changed the default configuration).  
Point  
This word means to move the mouse in such a way that the tip of the pointing  
arrow on the screen ends up resting at the desired location.  
Click  
Means to quickly press and release the left or right mouse button (as instructed in  
the procedure). Make sure you do not move the mouse pointer while clicking a  
mouse button.  
Double-click  
Drag  
Means to press and release the same mouse button two times quickly  
This word means to point the arrow and then hold down the left or right mouse but-  
ton (as instructed in the procedure) as you move the mouse to a new location.  
When you have moved the mouse pointer to the desired location, you can release  
the mouse button.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
About this guide  
Model 6511RC User Manual  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 Introduction  
Chapter contents  
Model 6511RC Matrix Switch overview................................................................................................................14  
Hardware overview................................................................................................................................................16  
ForeFront chassis architectures ........................................................................................................................19  
ForeFront Model 6476 6U cPCI chassis ...................................................................................................19  
The ForeFront Model 6676 9U chassis .....................................................................................................20  
Matrix Switch functionality ............................................................................................................................21  
TDM mapping and aggregation ................................................................................................................21  
TDM bus architecture ...............................................................................................................................22  
STM-1 link architecture ............................................................................................................................22  
Matrix Switch TDM capacity ....................................................................................................................23  
Matrix Switch Ethernet Switching ..................................................................................................................23  
Management ...................................................................................................................................................24  
Management Services ................................................................................................................................24  
Management Interfaces .............................................................................................................................24  
Management Approach .............................................................................................................................24  
Matrix Switch Interfaces .................................................................................................................................25  
WAN Interfaces ........................................................................................................................................25  
Mid-Plane Interfaces .................................................................................................................................25  
LAN Interface ...........................................................................................................................................25  
RS-232 Config port ..................................................................................................................................26  
Power system ..................................................................................................................................................26  
Central processing unit ...................................................................................................................................26  
System timing .................................................................................................................................................26  
Clocking Mode .........................................................................................................................................26  
Clocking Source ........................................................................................................................................26  
Temperature ...................................................................................................................................................27  
Altitude ...........................................................................................................................................................27  
Humidity ........................................................................................................................................................27  
Physical dimensions ........................................................................................................................................27  
LED Indicators ...............................................................................................................................................27  
Approvals ..............................................................................................................................................................29  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1 • Introduction  
Model 6511RC User Manual  
Model 6511RC Matrix Switch overview  
The Model 6511RC Matrix Switch (see figure 1) combines TDM aggregation and cross-connection with high-  
speed packet switching over synchronous digital hierarchy (SDH) and Ethernet uplinks for the Patton Fore-  
Front Access Infrastructure Solutions (AIS) system. The web-manageable Matrix Switch provides a fully non-  
blocking mapping and switching matrix for TDM and Ethernet traffic traversing the ForeFront chassis or chas-  
sis segment. With the Model 6511RC, ForeFront AIS can deliver aggregated TDM and IP traffic on high-  
speed SDH and Ethernet trunks. The Matrix Switch is designed for installation and operation in either the  
ForeFront Xtreme Model 6676 cPCI 9U chassis or the ForeFront FullPipe Model 6476 6U chassis. Each  
model 6511RC Matrix Switch includes an on-board TDM multiplexer, a powerful Ethernet switch, a 155  
Mbps SDH/STM-1 trunk port, and two 10/100/1000 Mbps Ethernet interfaces for high-speed packet-  
switched uplinks.  
Figure 1. Model 6511RC Matrix Switch front blade  
14  
Model 6511RC Matrix Switch overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
1 • Introduction  
Figure 2 shows the major functions and connections the Matrix Switch provides within the ForeFront chassis.  
Each Model 6511RC enables service providers to perform SDH multiplexing and demultiplexing with any-to-  
any timeslot mapping for up to 2048 DS0 channels. The on-board TDM multiplexer can map any of the 4096  
DS0 timeslots on the TDM bus in the chassis midplane to any of the 2048 DS0s on the STM-1 uplink. Each  
DS0 consists of a 64 kbps communication channel, or timeslot. The integrated SDH aggregator combines  
DS0 channels into E1 signal streams, then maps those E1s into a STM-1 signal for high-speed transmission on  
the SDH trunk.  
Figure 2. Model 6511RC Matrix Switch major functions and interfaces  
The Model 6511RC provides an Ethernet-switching fabric for packet-based management and user traffic tra-  
versing the ForeFront chassis. The powerful Ethernet switch connects the high-speed packet-switched bus in  
the ForeFront chassis midplane with two 10/100/1000 Ethernet uplinks. Offering fast Ethernet switching and  
flexible timeslot aggregation, the Model 6511RC Matrix Switch enables the ForeFront AIS system to deliver a  
surprisingly compact, high-speed trunking solution at very low cost.  
Model 6511RC Matrix Switch overview  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1 • Introduction  
Model 6511RC User Manual  
Hardware overview  
The Model 6511RC combines DS0 cross-connection and concentration with powerful Ethernet switching in a  
single-slot blade for installation in a standard CPCI chassis. The Matrix Switch card-set comprises two mod-  
ules, a processor blade (see figure 1 on page 14) inserted from the front of the ForeFront chassis, and a rear  
interface blade (see figure 3) inserted opposite to the processor blade. The front and rear blades mate at the  
mid-plane, which provides the communication path between front and rear blades (see figure 4).  
Figure 3. Model 6511RCT rear blade  
Midplane  
Front Blade  
Rear Blade  
Front  
Rear  
Side view  
Figure 4. Model 6511RC Matrix Switch front and rear blade installation  
16  
Hardware overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
1 • Introduction  
Figure 5. Model 6511RC front panel LEDs and ports  
The front panel of the processor blade presents LED status indicators, an RS-232 configuration port and a  
10/100 Ethernet management port (see figure 5). The rear entry interface blade (see figure 6 on page 18) pre-  
sents LEDs indicating alarm and WAN status, physical connectors for the STM-1 port, as well as two  
10/100/1000 Ethernet RJ-45 connectors with embedded link and activity status indicator LEDs.  
Hardware overview  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1 • Introduction  
Model 6511RC User Manual  
Figure 6. Model 6511RCT rear entry car front panel LEDs and ports  
Three versions of the rear card offer the following connector types for the STM-1 port:  
SC20—Optical interface presented on Rx and Tx SC connectors for singlemode fiber with a wavelength of  
1310 nm. The interface complies with ITU specifications G.957 and G.652.  
EBNC—Electrical interface presented on Rx and Tx 75-ohm BNC connectors.  
SC20/EBNC—Optical and electrical interfaces as described previously.  
The Model 6511RC connects to other blades in the chassis via the ForeFront cPCI chassis midplane. The chas-  
sis mid-plane contains two digital communications busses, the H.110 TDM bus, and the PICMG 2.16  
Packet-Switched Ethernet bus. The front blade connects to both busses via connectors on the chassis mid-  
plane. The blade uses the two mid-plane busses for digital communications with other processor blades  
installed and operating in the chassis.  
18  
Hardware overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model 6511RC User Manual  
1 • Introduction  
ForeFront chassis architectures  
The Model 6511RC can be installed in the following ForeFront cPCI chassis:  
Model 6476 6U chassis  
Model 6676 9U chassis  
ForeFront Model 6476 6U cPCI chassis  
The ForeFront Model 6476 6U cPCI chassis provides 8 slots for installing cPCI processor blades (see figure 7).  
The Model 6476 chassis accepts up to two Model 6511RC blades, installed in the fabric slots (designated by a  
yellow blade guide). Using the H.110 TDM and PICMG 2.16 packet busses residing in the chassis mid-plane,  
an installed Model 6511 can communicate with the other blades installed and operating in the remaining slots.  
Figure 7. Model 6476 chassis, front view  
Hardware overview  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
1 • Introduction  
Model 6511RC User Manual  
Figure 8. Model 6676 chassis, front view  
The ForeFront Model 6676 9U chassis  
The ForeFront Model 6676 9U chassis offers 17 slots for installing cPCI processor blades (see figure 8). The  
Model 6676 midplane is divided into segment R (slots 1 through 8) and segment L (slots 9 through 17). Each  
mid-plane segment contains its own H.110 and PICMG 2.16 bus, so since each 6511RC connects to one mid-  
plane segment, two Matrix Switch blades, installed in each of the two segments, are required to serve an entire  
Model 6676 chassis. The Model 6676 chassis can accept up to four Model 6511RC blades installed in slots  
called fabric slots (slots 1, 2, 9, and 10) designated by yellow card guides. In each backplane segment, a maxi-  
mum of two 6511RC blades can be installed for operation to provide switching functions for that segment.  
20  
Hardware overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
1 • Introduction  
The Model 6511 communicates with the other blades installed and operating in the same segment over the  
H.110 TDM and PICMG 2.16 packet busses residing in the chassis mid-plane.  
Matrix Switch functionality  
The Model 6511 provides the following functionality:  
TDM mapping and aggregation—The Model 6511RC Matrix Switch concentrates the traffic capacity of  
up to 63 E1 lines for delivery on a 155.54 Mbps optical or electrical STM-1 uplink (see section “TDM  
TDM bus architecture—The Matrix Switch provides an interface to the H.110 bus within the ForeFront  
chassis.The total capacity of the H.110 bus is 4096 half-duplex DS0 channels, the equivalent of 64 E1 lines  
(see section “TDM bus architecture” for details)  
STM-1 link architecture—The 155.52 Mbps STM-1 uplink carries 2016 full-duplex (4032 half-duplex)  
DS0 channels organized into 63 E1 signal streams. Each E1 stream carries 32 full-duplex DS0 channels (64  
half-duplex timeslots). The total capacity of the STM-1 uplink on the Model 6511RC is 2016 full-duplex  
DS0s, the equivalent of 63 E1 lines (see section “STM-1 link architecture” on page 22 for details)  
Matrix Switch TDM capacity—The Matrix Switch provides the means for you to map any DS0 on the  
H.110 TDM bus to any DS0 on the STM-1 trunk and vice-versa (see section “Matrix Switch TDM capac-  
ity” on page 23 for details)  
TDM mapping and aggregation  
The Model 6511RC Matrix Switch concentrates the traffic capacity of up to 63 E1 lines for delivery on a  
155.54 Mbps optical or electrical STM-1 uplink. For E1 traffic aggregation, the Matrix Switch performs mul-  
tiplexing and demultiplexing for all 63 E1 lines comprising the 155.52 Mbps STM-1 uplink. Each E1 line  
comprises 32 DS0 timeslots. Each timeslot comprises a 64 kbps communication channel, or DS0. The Model  
6511RC delivers a fully non-blocking switching matrix to the ForeFront system, providing any-to-any map-  
ping between all 4096 half-duplex DS0 timeslots carried in the H.110 bus and all 4032 half-duplex DS0  
timeslots in the SDH STM-1 uplink.  
Hardware overview  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1 • Introduction  
Model 6511RC User Manual  
TDM bus architecture  
The Matrix Switch provides an interface to the H.110 bus within the ForeFront chassis.The total capacity of  
the H.110 bus is 4096 half-duplex DS0 channels, the equivalent of 64 E1 lines (see figure 9). Each DS0 chan-  
nel can be mapped in either direction, transmitting to the Matrix Switch or receiving from the H.110 bus. The  
H.110 bus organizes the 4096 half-duplex DS0 channels into 32 H.110 ports. Each of the 32 H.110 ports car-  
ries 128 half-duplex 64 kbps timeslots (DS0s).  
Figure 9. H.110 bus and STM-Link capacity  
STM-1 link architecture  
The 155.52 Mbps STM-1 uplink carries 2016 full-duplex (4032 half-duplex) DS0 channels organized into 63  
E1 signal streams. Each E1 stream carries 32 full-duplex DS0 channels (64 half-duplex timeslots). The total  
capacity of the STM-1 uplink on the Model 6511RC is 2016 full-duplex DS0s, the equivalent of 63 E1 lines.  
The following sequence describes the process by which the Matrix Switch maps and multiplexes 63 E1 streams  
into the architecture of the STM-1 signal stream:  
E1 -to- C-12 -to- VC-12 -to- TU-12 -to- TUG-2 -to- VC-3 -to- AU-3 -to- AUG-1 -to- STM-1  
Multiplexing occurs at the following points in the mapping sequence:  
- Three TU-12s are multiplexed into one tributary unit group-2 (TUG-2).  
- Seven TUG-2s are multiplexed into one TUG-3 or administrative unit-3 (AU-3).  
- Three AU-3s or TUG-3s are multiplexed into one administrative unit group-1 (AUG-1).  
22  
Hardware overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
1 • Introduction  
Figure 10 highlights the multiplexing structure of the STM-1 link by ommitting the intermediate steps in the  
SDH mapping sequence  
Figure 10. E1-to-STM-1 multiplexing structure  
Matrix Switch TDM capacity  
The Matrix Switch provides the means for you to map any DS0 on the H.110 TDM bus to any DS0 on the  
STM-1 trunk and vice-versa. The difference in capacity between the H.110 bus and the STM-1 link is 64 half-  
duplex DS0s, the equivalent of one E1 line. The STM-1 uplink provides sufficient capacity to aggregate 98%  
of the traffic capacity of the H.110 TDM bus. The Model 6511RC provides the capability to map and aggre-  
gate traffic on the H.110 bus up to the full capacity of the STM-1 trunk.  
Matrix Switch Ethernet Switching  
The Matrix Switch also delivers Ethernet connectivity and switching for any Ethernet traffic traversing the  
PICMG 2.16 bus to which the blade is connected. The Model 6511RC provides the Ethernet switching fabric  
for all other blades connected to the same PICMG 2.16 packet-switching bus within the chassis mid-plane.  
The built-in Ethernet switch switches Ethernet traffic between the PICMG 2.16 bus, the 10/100 Ethernet  
LAN port presented on the front panel of the front blade, and the two 10/100/1000 Ethernet WAN uplink  
ports presented on the 6511RCrear panel of the rear blade. All three Ethernet ports provide access to the  
SNMP agent and HTTP Web Management services within the 6511RC. In addition, all three Ethernet ports  
provide access via the Internet Protocol to the other blades on the packet bus, including access to the Web  
Management services residing within those blades. When combined with an external network management  
system, the Ethernet switching feature on the 6511RC makes it possible to implement a packet-based network  
management solution for all system elements connected to the same packet-switched bus in the ForeFront  
chassis.  
Hardware overview  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
1 • Introduction  
Model 6511RC User Manual  
Management  
Management Services  
By providing a rich set of industry-standard management services accessible by a full menu of physical inter-  
faces, the Model 6511RC offers an extensive selection of management options. The Matrix Switch provides the  
following management services:  
HTTP Web-Management Interface accessible via any standard web browser  
SNMP version 1 configuration management (specified in RFC 1157)  
MIB II (specified in RFC 1213)  
Command Line Management Interface (CLI)  
SYSLOG Management Client (specified in RFC 3164)  
Out-of-Band RS-232 configuration port for management and control  
TELNET via Ethernet  
Remote Software Upgrade via FTP/TFTP  
Management Interfaces  
You can reach the Matrix Switch’s management services via any of the following physical interfaces:  
RS-232 Config Port presented as an RJ-45 connector on the front panel of the front blade  
PICMG 2.16 midplane connector block on the front blade  
10/100 Ethernet port presented as an RJ-45 connector on the front panel of the front blade.  
Two 10/100/1000 Ethernet ports presented as RJ-45 connectors on the rear panel of the rear blade  
Management Approach  
Managing the Model 6511RC’s may be approached using one of two schemes, generally referred to as In-band  
or Out-of-band management. In-band management refers to those schemes in which management informa-  
tion traverses the same network resources as network user traffic. Out-of-band management refers scenarios in  
which management information does not traverse the same resources as network user traffic. In other words,  
out-of-band management involves implementing a secondary, special-purpose, management network dedi-  
cated to carrying management information about the primary, user network. In-band management is more  
efficient. However, because management information is susceptible to failures in the user network., it is less  
reliable. Out-of-band management, while more reliable, is also more costly because it involves more equip-  
ment.  
Management access paths into the Model 6511RC for both In-band and Out-of-band approaches are  
described below.  
In-band management access paths include:  
- The two RJ-45 10/100/1000 Ethernet trunk ports on the rear panel of the rear blade support in-band  
management for applications where the Ethernet link is used as an aggregated trunk for user traffic as well  
as a path for management information. An external management workstation communicates with the  
management services in the Matrix Switch via a routed-protocol connection within the Ethernet link.  
The management connection terminates at the management service within the Matrix Switch.  
24  
Hardware overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Model 6511RC User Manual  
1 • Introduction  
- The PICMG 2.16 packet-switched bus (PSB). In order to manage the Matrix Switch in-band via the  
PICMG 2.16 PSB, an external management workstation connects to the ForeFront chassis via another  
ForeFront blade with management routing capability, such as the Model 6801RC EdgeRoute Network  
Access Server or model 3096RC TDM Digital Access Concentrator, operating on the same bus. The  
external management workstation communicates with the ForeFront system using either a Frame Relay  
or PPP link within a DS0 or within an Ethernet link. The in-band management link terminates on the  
module with management routing capability, which in turn communicates with the management services  
in the Matrix Switch over the PICMG 2.16 PSB.  
Out-of-band management access paths include:  
- The RS-232 config port on the front panel of the front blade  
- The RJ-45 10/100 Ethernet LAN port on the front panel of the front blade  
- The two RJ-45 10/100/1000 Ethernet LAN ports on the rear panel of the rear blade, in applications  
where these Ethernet links are dedicated to management traffic.  
Matrix Switch Interfaces  
WAN Interfaces  
The 6511RC provides connections to the following WAN interfaces:  
One SDH STM-1 uplink trunk port at 155.54 Mbps  
-Physical SC or BNC connectors presented on the rear-blade rear panel  
Two Ethernet trunk ports at up to 1 Gbps  
-Physical RJ-45 connectors presented on the rear-blade rear panel  
The STM-1 WAN uplink port may be connected to an SDH network via the Optical SC ore electrical BNC  
connectors presented on the rear blade.  
Mid-Plane Interfaces  
Connection to the H.110 Time-Division Multiplexed bus providing 4096 DS0 channels of 64 kbps each  
-Physical and electrical connections via the mid-plane connector block on the rear of the front blade  
Connection to the PICMG 2.16 Packet-Switched Bus (PSB)  
-Physical and electrical connections via the mid-plane connector block on the rear of the front blade  
LAN Interface  
The 10/100-Mbps Ethernet LAN port is presented on an RJ-45 connector with an auto-sensing/full-duplex  
10Base-T or 100Base-T interface. Also included are:  
100Base-TX half-/full-duplex operation (100 + 100)  
10Base-T half-/full-duplex operation (10 + 10)  
Auto detection and fallback  
10/100 Mbps link and status indicators  
Hardware overview  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
1 • Introduction  
Model 6511RC User Manual  
RS-232 Config port  
The RS-232 Config port provides access to the CLI management service. You will use the Config port to per-  
form initial configuration of the Model 6511RC. The RS-232 port supports:  
Asynchronous data rates of 19.2 kbps, 8 data bits, no parity, 1 stop bit.  
An RJ-45 connector with EIA-561 pinouts  
A management interface that supports VT-100 terminals  
Hardware flow control (RTS and CTS)  
Power system  
The 6511RC obtains power from the CPCI chassis via PCMG 2.11 47-pin power connectors on the front and  
rear blade. Total power consumption is a maximum of 43 Watts, provided by modular power supplies installed  
in the cPCI chassis.  
Central processing unit  
The 6511RC employs an Intel i960VH RISC processor operating at 100 MHz/100 Mips. The CPU controls  
the memory, front/back-panel and management interface for DS0 timeslot mapping, Ethernet switching, loop-  
back and management services. System memory provided by:  
4 MB Flash ROM  
8 MB EDO DRAM  
System timing  
The system timing for the Matrix Switch must be configured using the blade’s management services, typically  
via Web Management.  
Clocking Mode  
When configured in Master mode, the Matrix Switch serves as the Master clock source (timing reference) for  
all other blades on the same H.100 bus within the Model 6476 chassis or Model 6676 chassis segment. When  
configured in Backup mode, the Matrix Switch serves as an alternate Master clocking source (backup) should  
the Master clocking source fail. When configured in Slave mode, the Matrix Switch will not provide system  
timing over the H.100 bus for any other blades.  
Clocking Source  
Regardless of its clocking mode, the Matrix Switch can derive its own system timing from several sources. You  
will define two clocking sources for the Matrix Switch, a first-choice (Primary Reference) and an alternate  
(Fallback Reference). The Matrix switch will derive its own system timing from the Primary Reference as long  
as it remains available. Should the Primary Reference become unavailable, the Matrix Switch will switch over  
to the Fallback reference as the clock source for its own system timing. The following clocking sources can  
serve as either the Primary Reference or Fallback Reference for the Matrix Switch:  
The internal oscillator (clock) residing on the Matrix Switch front blade  
A network clock recovered from the STM-1 SDH signal stream  
Another blade operating in either Primary or Secondary mode on the same bus.  
26  
Hardware overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Model 6511RC User Manual  
1 • Introduction  
Temperature  
Operating range: 32–104°F (0–40°C)  
Altitude  
Maximum operating altitude: 15,000 feet (4,752 meters)  
Humidity  
5 to 95% relative humidity (RH), non-condensing  
Physical dimensions  
1.75 inches (4.44 cm) height, standard 19-inch (48.26 cm) width, 12-inch (30.48 cm) depth  
Weight: 1.55 lbs (0.70 kg)  
LED Indicators  
LED indicators on the front panel (see figure 5 on page 17) and rear panel (see figure 6 on page 18) display the  
status of Matrix Switch system resources. The front-panel LEDs are described in table 3. The rear-panel LEDs  
are described in table 4 on page 28.  
Table 3. Front-panel LED indicators  
LED  
POWER  
Color Status  
Meaning  
Green On solid Power is being applied.  
Flashing The 6511RC has detected a power failure on a power bus.  
Off No input power is being applied.  
On solid CPU is unable to load the software from FLASH to RAM for operation.  
Off The CPU is operating normally.  
CPU FAIL  
ALARM  
Red  
Yellow On solid A minor alarm condition has been detected.  
Flashing A major alarm condition has been detected.  
Off  
Green Flashing The Model 6511RC system is operating normally.  
Off The Model 6511RCsystem is not functioning properly.  
The Model 6511RC system is operating normally.  
SYSTEM  
ENET(NODE)  
Green On solid Indicates there is Ethernet frame activity on one or more of the 6511RC’s Ethernet inter-  
faces, including the two rear-panel 10/100/1000 ports, the front -panel 10/100 port,  
and the packet--switched PICMG 2.16 bus.  
Off  
Indicates NO Ethernet frame activity detected on any of the 6511RC’s Ethernet interfaces,  
including the PICMG 2.16 bus.  
CLK SOURCE  
CLK ERROR  
Green On solid The 6511RC is defined as the Primary (master) clock source for the H.100 bus  
Flashing The 6511RC is defined as the Secondary (alternate master) clock source.  
Off  
The 6511RC is defined as a slave, deriving its clock from the H.110 Bus.  
Yellow On solid Primary Master Clock source has been lost and the 6511RC is using the secondary  
source for its clock.  
Flashing Master Clock source and the Secondary Clock source have been lost and the 6511RC  
is using its internal crystal for its clock.  
Off  
No clock errors currently detected.  
Hardware overview  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
             
1 • Introduction  
Model 6511RC User Manual  
Table 3. Front-panel LED indicators (Continued)  
LED  
Color Status  
Meaning  
TEST MODE  
Green On solid One or more Ethernet ports or the STM-1 port is in test mode.  
Flashing One or more Ethernet ports or the STM-1 port is in test mode and errors have been  
received.  
Off  
None of the ports is operating in test mode.  
WAN  
Green On solid Indicates the STM-1 port is activated, synched, and operating normally.  
Flashing Indicates that the STM-1 port is detecting the SDH network, but is unable to synchro-  
nize with it.  
Off  
Indicates rear blade not present or STM-1 port is not configured  
ENET(SWITCH) Green On solid Indicates there is Ethernet frame activity on at least one of the eight PICMG 2.16 connec-  
tions to other blades on the PSB bus.  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
No Ethernet frame activity detected on the PICMG 2.16 bus.  
Indicates Ethernet frame activity on one or both of the 10/100/1000 Ethernet ports  
There is NO Ethernet frame activity on either of the 10/100/1000 Ethernet ports  
Reserved for future use  
Reserved for future use  
Ethernet Link is established  
ENET(REAR)  
ON LINE  
Green  
10/100 ENET  
Integrated LEDs  
on RJ-45  
Green  
Yellow  
Blue  
No Ethernet link is established  
Flashes to indicates Ethernet frame activity on this port  
Indicates no Etherent frame activity on this port  
Card ready for removal from cPCI chassis.  
Connector  
READY  
Card not ready for removal from cPCI chassis.  
Table 4. Rear-panel LED indicators  
LED  
Color Status  
Meaning  
ALARM  
Red  
On solid A minor alarm condition has been detected.  
Flashing A major alarm condition has been detected  
Off  
The Model 6511RC is operating normally.  
WAN  
Green On solid Indicates the STM-1 port is activated, synched, and operating normally.  
Flashing Indicates that the STM-1 port is detecting the SDH network, but is unable to synchro-  
nize with it.  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
Indicates rear blade not present or STM-1 port is not configured  
Ethernet Link is established  
No Ethernet link is established  
Flashes to indicates Ethernet frame activity on this port  
Indicates no Etherent frame activity on this port  
Ethernet Link is established  
ENET 1  
Integrated LEDs  
Green  
Yellow  
Green  
on RJ-45  
Connector  
ENET 2  
Integrated LEDs  
No Ethernet link is established  
on RJ-45  
Flashes to indicates Ethernet frame activity on this port  
Indicates no Etherent frame activity on this port  
Card ready for removal from cPCI chassis.  
Card not ready for removal from cPCI chassis.  
Connector  
Ready  
Blue  
28  
Hardware overview  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model 6511RC User Manual  
1 • Introduction  
Approvals  
The Model 6511RC Matrix Switch has achieved the following approvals and certifications:  
Safety  
- UL 60950  
- Industry Canada CSA C22.2 No. 60950  
RTTE Directive (CE Mark)  
- EMC Directive 89/336/EEC  
- Low Voltage Directive 73/23/EEC (EN 60950)  
- ETSI CTR 12  
- ETSI CTR 13  
EMC  
- FCC Part 15, Subpart B, Class A  
Telecom  
- FCC Part 68  
- Industry Canada CS-03  
Approvals  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1 • Introduction  
Model 6511RC User Manual  
30  
Approvals  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 Hardware installation  
Chapter contents  
Introduction..........................................................................................................................................................32  
Unpacking the Model 6511RC Matrix Switch ......................................................................................................32  
Verifying that the ForeFront chassis is properly installed .......................................................................................32  
Verfying correct electrical grounding ...............................................................................................................33  
Verifying correct cover plate installation .........................................................................................................33  
Matrix Switch hardware installation ......................................................................................................................34  
Installing the network cables..................................................................................................................................35  
Connecting the front-panel Ethernet LAN port ..............................................................................................36  
Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hub ...............................................36  
Connecting the rear-panel STM-1 WAN port to an SDH network ................................................................37  
Connecting the STM-1 optical interface to fiber-optic network cables ......................................................37  
Connecting the STM-1 electrical interface to coaxial network cables .........................................................38  
Connecting the rear-panel Ethernet WAN/management ports ........................................................................39  
Completing the hardware installation....................................................................................................................40  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2 • Hardware installation  
Model 6511RC User Manual  
Introduction  
This chapter contains the following procedures for installing the Model 6511RC Matrix Switch:  
Note Before installing the Matrix Switch, you will need to obtain the line  
type and encoding of the STM-1 link from your local telephone com-  
pany (Telco).  
“Unpacking the Model 6511RC Matrix Switch”—lists the contents in the Matrix Switch shipping con-  
tainer  
“Matrix Switch hardware installation”—describes installing the Matrix Switch on a flat surface or in a stan-  
dard 19-inch rack  
“Installing the network cables” on page 35—describes installing the power and network interface cables  
“Completing the hardware installation” on page 40—describes testing the Matrix Switch hardware to verify  
that it is ready for software configuration  
Unpacking the Model 6511RC Matrix Switch  
Inspect the shipping carton for external damage. Note any damage before removing the container contents.  
Report equipment damage to the shipping carrier immediately for claim purposes. Save all packing materials in  
case you need to return an item to the factory for servicing.  
The Matrix Switch comes with the following items:  
The Model 6511RC Digital Cross-Connect (Matrix Switch)  
One RJ45-to-RJ45 cable for use with the console and Ethernet ports  
A DB9-RJ45 (EIA-561) adapter for connecting a PC's serial port to the Matrix Switch console port  
Verifying that the ForeFront chassis is properly installed  
You must verify that the ForeFront chassis is correctly installed before installing the Matrix Switch hardware  
into the chassis. Check for the following:  
Correct electrical grounding—Improper chassis grounding may impair proper operation of the STM-1  
electrical interface, thereby causing data transmission errors on the STM-1 link. See section “Verfying cor-  
rect electrical grounding” on page 33 for directions on verify chassis grounding.  
Correctly installed front and rear panels over vacant chassis slots—Absent front or rear panels over vacant  
module slots leaves the chassis interior open and thereby vulnerable to the following problems:  
- Improper EMI shielding against both incoming and outgoing electromagnetic signals  
- Impaired operation of the chassis cooling system, resulting in equipment overheating, including the SHD  
laser subsystem on the Matrix Switch  
See section “Verifying correct cover plate installation” on page 33 for directions on verifying proper cover  
plate installation  
32  
Introduction  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
2 • Hardware installation  
Verfying correct electrical grounding  
Do the following to verify correct electrical grounding:  
Improper chassis grounding may impair the operation of the  
STM-1 electrical interface, thereby causing data transmission  
errors on the STM-1 link.  
1. Inspect the rack chassis grounding studs on the AC power module or DC power module (see figure 11 for  
studs locations) to ensure a #12 AWG ground wire is attached.  
Figure 11. AC power module and DC power module grounding studs locations  
2. Inspect the remote end the #10 AWG ground wire and verify that it is attached to one of the following  
grounding sources:  
– The building ground rod (generally located at the site’s main service entrance)  
– A sprinkler system pipe  
– A cold-water pipe  
– Building structural steel  
Verifying correct cover plate installation  
Missing front or rear panel cover plates leave the chassis interior open and vulnerable to the following problems:  
Impaired EMI shielding against incoming and outgoing electromagnetic signals  
Reduced chassis cooling system efficiency, which can resulting in equipment overheating, especially in the  
SHD laser subsystem on the Matrix Switch  
Do the following to verify that cover plates are properly installed:  
1. Inspect the front of the chassis and verify that a cover plate is installed for each vacant module slot, and  
verify that each cover plate’s fasteners are tightened securely to the front panel. Missing cover plates must  
be replaced before installing the Matrix Switch.  
Verifying that the ForeFront chassis is properly installed  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2 • Hardware installation  
Model 6511RC User Manual  
Note Missing cover plates can be replaced by calling Patton Sales at  
+1 (301) 975-1000. The Sales Department is available Monday  
through Friday, from 8:00 A.M. to 5:00 P.M. EST (8:00 to  
17:00 UTC-5).  
2. Inspect the rear of the chassis and verify that a cover plate is installed for each vacant module slot, and ver-  
ify that each cover plate’s fasteners are tightened securely to the rear panel. Missing cover plates must be  
replaced before installing the Matrix Switch.  
Matrix Switch hardware installation  
Do the following to install the Matrix Switch hardware:  
1. Remove the Matrix Switch rear blade from its shipping container.  
Note Be sure to wear the anti-static strap to prevent electrostatic damage to  
the blade.  
Note The Matrix Switch should be installed as close as possible to the ter-  
mination jack provided by the Telco. The location should be well  
ventilated. Do not block the rack chassis’ cooling vents.  
2. Remove the slot cover plate, if present.  
3. Unlatch both handles on the Matrix Switch blade by pressing in on the red release button in each handle  
(see figure 12).  
4. While holding the Matrix Switch from the card handles (see figure 12), align the Matrix Switch with the  
guide rails of the appropriate slot and slide it back until it touches the backplane connectors and the align-  
ment/ESD pin (see figure 12) engages the chassis. When the blade is fully seated, the red release buttons in  
the handles click up automatically, thus locking the handles.  
Figure 12. Alignment/ESD pin and card handle  
5. Tighten the screw fastener located inside each handle to secure the blade to the chassis.  
34  
Matrix Switch hardware installation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
2 • Hardware installation  
6. Insert the front blade into the front chassis slot corresponding to the slot in which you installed the rear  
blade. Verify that the release buttons in the handles click up to indicate that the board is fully seated and  
locked into place.  
Installing the network cables  
This section describes installing network interface cables on the following front and rear Matrix Switch  
blade ports:  
The Matrix Switch front blade’s 10/100 Ethernet LAN port and an EIA 561 RS-232 CONFIG port  
(see figure 13).  
The Matrix Switch rear blade’s STM-1 SDH WAN port (presented in SC optical and 75-ohm BNC electri-  
cal formats) and two 10/100/100 Ethernet WAN/LAN management ports (see figure 14)  
Figure 13. Matrix Switch front blade network interface ports  
Figure 14. Matrix Switch rear blade network interface ports  
Installing the network cables  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2 • Hardware installation  
Model 6511RC User Manual  
Connecting the front-panel Ethernet LAN port  
The Matrix Switch includes a 10/100Base-T transceiver, accessible via a physical interface on the front panel of  
the front blade for connection to an Ethernet LAN. The Ethernet interface complies with IEEE 802.3 and is pre-  
sented on a 6-pin RJ-45 female receptacle. Once connected to a LAN, the Ethernet port will autosense the speed  
of the LAN and automatically negotiate half or full-duplex operation. This port provides access to the Matrix  
Switch’s resident management services, including the HTTP/Web Management feature. This port also connects  
to the on-board Ethernet Switch, thus providing Ethernet access to other blades within the ForeFront system via  
the PICMG 2.16 PSB. This section describes connecting the Matrix Switch to the Ethernet LAN via an Ethernet  
hub, switch, or workstation.  
Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hub  
The 10/100Base-T Ethernet port (see figure 5) is designed to connect to an Ethernet switch or hub. The  
Ethernet RJ-45 pin and signal definitions for the Matrix Switch or for a NIC card in a workstation/PC are  
shown in figure 15. Connect a straight-through CAT-5 cable (one wired as shown in figure 15) between the  
Matrix Switch and the hub/switch.  
Figure 15. Ethernet RJ-45 pin and signal definitions for Matrix Switch  
Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PC  
The 10/100Base-T Ethernet port can connect to a single Ethernet-capable workstation or PC by means of a  
cross-over cable. Refer to figure 16 to assemble a cross-connect cable that will connect between the NIC Ether-  
net port in the workstation and the Matrix Switch 10/100Base-T Ethernet port.  
Figure 16. Cross-over RJ-45-to-RJ-45 Ethernet cable diagram  
36  
Installing the network cables  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Model 6511RC User Manual  
2 • Hardware installation  
Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)  
Install the supplied RJ-45-to-RJ-45 cable with the DB9-RJ45 adapter between the Matrix Switch RS-232 port  
(see figure 13 on page 35) and an open serial port on your computer. If you need to assemble your own cable,  
refer to the pinout diagram in figure 17.  
Figure 17. RJ-45 pin and signal definitions for Matrix Switch CONFIG port  
Connecting the rear-panel STM-1 WAN port to an SDH network  
The Matrix Switch offers two types of STM-1 interfaces—optical and electrical—presented on the rear panel of  
the rear blade. Optical interfaces connect to fiber-optic network cables, while the electrical interfaces connect to  
coaxial network cables. The rear-blade connectors must match the type of network cables and connectors used by  
the SDH network to which you will connect.  
Connecting the STM-1 optical interface to fiber-optic network cables  
The following versions of the Matrix Switch rear blade offer an optical interface for the STM-1 port  
Model 6511RC/M155/SC20  
Model /EBNC6511RC/M155/SC20  
The designation SC20 in the model code denotes that an optical interface conforming to ITU specification  
G.957 and G.652 is present. The Matrix Switch presents the STM-1 optical interface on a pair of SC fiber-  
optic connectors, one for the transmiting (TX) and one for receiving (RX) signals (see figure 14 on page 35).  
Note The wavelength of the laser signal is 1310 nanometers. The single-  
mode fiber-optic cable connecting the STM-1 WAN port to the SDH  
network must extend no farther than 12.4 miles (20 kilometers).  
Installing the network cables  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
2 • Hardware installation  
Model 6511RC User Manual  
Figure 18. Fiber-optic SC cable connectors  
Do the following to connect the dual singlemode fiber-optic cable (see figure 18) to the STM-1 SC connectors:  
1. Remove the protective cap from the fiber optic cable connectors.  
2. Attach the transmit fiber-optic cable connector to the TX SC connector on the rear blade (see figure 14 on  
page 35).  
3. Attach the receive fiber-optic cable connector to the RX SC connector on the rear blade.  
Connecting the STM-1 electrical interface to coaxial network cables  
The Matrix Switch presents the STM-1 electrical interface on a pair of 75-ohm female BNC connectors, one  
for the transmiting (TX) and one for receiving (RX) signals (see figure 14 on page 35).  
For most installations, the coaxial cable connecting the STM-1 WAN port to the SDH network can be no  
longer than 325 feet (100 meters).  
Note The Matrix Switch electrical interface transmits a STM-1 signal with  
an attenuation margin of 12.7dB at 78 MHz over coaxial cable. The  
12.7dB attenuation margin typically results in a transmission distance  
limitation of approximately 360 feet (110 meters) for RG-59U  
coaxial cable.  
38  
Installing the network cables  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
2 • Hardware installation  
Figure 19. BNC coaxial cable connectors  
Do the following to connect the dual 75-ohm coaxial cable (see figure 19) to the STM-1 BNC connectors:  
1. Attach the transmit connector of the coaxial cable to the TX connector on the rear blade (see figure 14 on  
2. Attach the transmit connector of the coaxial cable to the RX connector on the rear blade.  
Connecting the rear-panel Ethernet WAN/management ports  
The Matrix Switch provides two 10/100/1000Base-T Ethernet transceivers, accessible via physical interfaces  
on the rear-panel of the rear blade, for connection to an external router, hub, or switch. Both interfaces are pre-  
sented on RJ-45 6-pin female receptacles. The interfaces comply with IEEE specification 802.3 and are labeled  
ENET 1 and ENET 2 (see figure 14 on page 35).  
Once connected to a LAN, the Ethernet port will autosense the speed of the LAN and automatically negotiate  
half or full-duplex operation. The ports provide access to the Matrix Switch’s resident management services,  
including the HTTP/web management feature. This port also connects to the on-board Ethernet switch, thus  
providing Ethernet access to other blades within the ForeFront system via the PICMG 2.16 PSB.  
You can use the two high-speed Ethernet ports to implement the following functions:  
Ethernet trunks. You can connect the 10/100/100 Ethernet ports to a WAN router in order to deliver  
high-speed aggregated packet-based traffic to and from the ForeFront system over packet-switched WAN  
trunks. The WAN router would then be connected to a private WAN or to the Internet.  
Ethernet management network. You can connect the 10/100/100 Ethernet ports to a local area network  
via an external hub or switch in order to implement an out-of-band management network. To create an  
external management network, all ForeFront blades must connect to the management LAN via an Ethernet  
port residing on each blade. The Matrix Switch also offers access to an internal management network, the  
PICMG 2.16 PSB. By means of its on-board Ethernet switch, the Matrix Switch provides a packet-switched  
path to all blades operating on the same PICMG 2.16 bus, which a Network Management System can use  
to communicate with the management services on those blades.  
Installing the network cables  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2 • Hardware installation  
Model 6511RC User Manual  
Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switch  
The 10/100/100Base-T Ethernet ports may be connected to a WAN router, or to an Ethernet hub or switch.  
To connect the router, hub or switch to the Matrix Switch, you must use a straight-through CAT-5 RJ-45  
cable (one wired as shown in figure 15 on page 36). Figure 15 shows the Ethernet RJ-45 pin and signal defi-  
nitions for the Matrix Switch. For cable distance limitations please consult the IEEE specification 802.3.  
To connect the 10/100/100 Base-T Ethernet port to a router, hub or switch:  
1. Connect the RJ-45 connector at one end of the cable into the 6-pin RJ-45 receptacle on the rear-panel of  
the 6511RC rear-blade.  
2. Connect the RJ-45 connector at other end of the cable into the 6-pin RJ-45 receptacle on the router, hub,  
or switch.  
Completing the hardware installation  
This section verifies that the Matrix Switch hardware is operational to the point where you can begin configur-  
ing the software settings.  
Power is delivered from the CPCI chassis backplane through the 47-pin PICMG 2.11 power connectors on  
the 6511RC blades. Upon insertion into the CPCI chassis, the Model 6511RC immediately powers up and  
begins its boot cycle. During the boot cycle the following should occur:  
1. The POWER LED illuminates, indicating normal power is being applied to the 6511RC.  
2. The green SYSTEM LED begins flashing, indicating the 6511RC is operating normally.  
Hardware installation is now complete. To configure the 6511RC for operation, refer to chapter 3, “Configur-  
40  
Completing the hardware installation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Chapter 3 Configuring the Matrix Switch for  
operation  
Chapter contents  
Introduction..........................................................................................................................................................42  
Configuration prerequisites ...................................................................................................................................42  
Initial configuration through the RS-232 control port...........................................................................................43  
Connecting the DB9-RJ45 adapter with the included cable ............................................................................43  
Setting up the HyperTerminal (or similar program) session ............................................................................44  
Using a browser to complete Model 6511RC configuration ..................................................................................47  
Displaying the Matrix Switch 6511RC web administration pages ...................................................................47  
Home page overview .................................................................................................................................49  
Configuring the default gateway .....................................................................................................................51  
Configuring the system clocking parameters ...................................................................................................52  
Module clocking mode ..............................................................................................................................52  
Module clocking source and fallback .........................................................................................................53  
Example 1 ........................................................................................................................................... 53  
Example 2 ........................................................................................................................................... 54  
Configuring the SDH circuit parameters ........................................................................................................54  
Accessing the SDH circuit parameters .......................................................................................................55  
Configuring the SDH physical interface type ............................................................................................56  
Configuring the SDH interface parameters ...............................................................................................56  
Configuring the SDH path trace parameters .............................................................................................57  
Configuring DS0 idle codes ............................................................................................................................58  
Accessing the idle code configuration ........................................................................................................59  
Defining the DS0 idle code configuration .................................................................................................60  
Selecting the SDH mapping path ....................................................................................................................60  
Defining DS0 mappings .................................................................................................................................62  
Defining DS0 mappings using E1 port format ..........................................................................................64  
Examples for configuring DS0 mappings. .................................................................................................65  
Defining DS0 mappings using TU format ................................................................................................69  
Examples for configuring DS0 mappings. .................................................................................................72  
Saving your configuration ...............................................................................................................................74  
Backing up your configuration parameters.............................................................................................................75  
Backing up the configuration store in flash memory .......................................................................................76  
Completing the installation ...................................................................................................................................77  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Introduction  
This chapter contains the following procedures that describe configuring the Model 6511RC Matrix Switch  
for operation:  
“Configuration prerequisites”—lists the items you need to have on hand before configuring the Matrix  
Switch.  
6511RC’s LAN IP address and netmask parameters.  
remaining basic configuration parameters in order to bring your Matrix Switch on-line. The procedures  
include the following steps:  
- Displaying the Matrix Switch home page (see “Displaying the Matrix Switch 6511RC web administra-  
- Defining the IP default gateway (see “Configuring the default gateway” on page 51)  
- Defining the system clocking parameters (see “Configuring the system clocking parameters” on page 52  
- Defining the STM-1 Circuit parameters (see “Configuring the SDH circuit parameters” on page 54)  
- Enabling idle code generation for designated DS0 channels (see “Configuring DS0 idle codes” on  
- Defining DS0 mappings within the STM-1 link (see “Selecting the SDH mapping path” on page 60)  
“Saving your configuration” on page 74—describes how to save your configuration settings.  
“Backing up your configuration parameters” on page 75—describes how save your configuration parame-  
ters to a file  
“Completing the installation” on page 77—describes how to verify that your 6511RC Matrix Switch is  
fully operational.  
Configuration prerequisites  
You will need the following to configure the 6511RC Matrix Switch:  
A PC equipped with the following:  
- RS-232/V.24 serial port  
- VT-100 terminal program, e.g., HyperTerminal  
- Ethernet port  
- Web browser (e.g., Netscape Communicator or Microsoft Internet Explorer)  
You will need the following information to configure the Model 6511RC:  
- The IP address and subnet mask for the 6511RC’s Ethernet port  
- The IP address of the default gateway  
To configure the STM-1 link, you will need the following information from the SDH network to which  
you are connecting:  
42  
Introduction  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
- Which E1 mapping path will be used within the STM-1 link, either AU3 or AU4.  
- Section Trace Message Length  
- The value of the JO byte for Section Trace Messages  
- Path-1 Trace Message Length  
- The value of the J1 byte for Path-1 Trace Messages  
- The value of Path-1 Signal Label  
- The E1 payload type, either asynchronous or byte synchronous  
To configure the DS0 mappings, you will need  
- a detailed plan describing the desired source and destination for each of the 4096 simplex DS0 channels  
within the H.110 bus on the chassis mid-plane  
- which DS0 channels within each E1 signal stream should carry an idle code  
Initial configuration through the RS-232 control port  
Initially you must configure the 6511RC’s IP address via the RS-232 Config port located on the Matrix Switch  
front frame. In rare instances, you may also need to change the netmask from the factory default value.  
Note The Model 6511RC must be installed, powered-up, and operating  
before you can perform the initial configuration. If it is not, you must  
first complete the procedures described in chapter 2, “Hardware  
Connecting the DB9-RJ45 adapter with the included cable  
Do the following:  
1. Find the DB9-RJ45 adapter for your PC and RJ-45-to-RJ45 cable shipped with your 6511RC Matrix  
Switch.  
2. Connect the DB9-RJ45 adapter to your PC’s RS-232 serial port.  
3. Connect the RJ45-RJ45 cable between the adapter that you installed in step 1 and the CONFIG port on  
the front of the Model 6511RC (figure 20).  
Figure 20. Model 6511RC interface ports  
Initial configuration through the RS-232 control port  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Setting up the HyperTerminal (or similar program) session  
Do the following:  
1. At your PC, find the file HYPERTRM.EXE. Open a HyperTerminal session by double-clicking on the  
file name.  
Figure 21. Connection Description window  
2. Type a connection name (e.g., 6511RC Config), select an icon, then click OK (figure 22).  
Figure 22. Connect To window  
3. On the Connect To window (figure 22), set Connect using: to one of the options named Direct to ComX  
(where the “X” refers to the number identifying the RS-232 serial port on the PC). In the following proce-  
dure, Com1 will be the used as the port identifier.  
4. Click OK.  
5. The COM1 Properties window displays.  
44  
Initial configuration through the RS-232 control port  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
6. Configure your COM port settings as shown in figure 23, then click OK.  
Figure 23. COM1 Properties window  
7. Click on the File menu, then select Properties.  
8. Configure the settings for Function, arrow and ctrl keys act as to Terminal keys as shown in figure 24, then  
click OK.  
Figure 24. Terminal keys configuration  
Initial configuration through the RS-232 control port  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
9. Connect the male end of the 6511RC Matrix Switch’s power cables to the power outlets.  
10. Boot up information will display on your HyperTerminal connection window, eventually followed by a  
login request window (see figure 25).  
Figure 25. Login window  
11. For the user name, type superuser.  
12. For the password, type superuser; the TOP LEVEL MANAGEMENT window then appears (see  
Figure 26. VT-100 Top Level Management window  
13. Type  
14. Under System, type  
15. Enter for LAN Address, then press <Enter>.  
k
for System, then press <Enter>.  
1
for Details, then press <Enter>.  
g
16. Type your LAN IP address followed by pressing <Enter>.  
17. Press the left-arrow cursor key on your keyboard to return to the previous screen.  
18. If you do not need to change the LAN Mask from the default of 255.255.255.0, go to step 21. Otherwise,  
press  
h
and type the new LAN Mask in the same manner as when entering a LAN IP address.  
46  
Initial configuration through the RS-232 control port  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
19. Press the left-arrow cursor key until the TOP LEVEL MANAGEMENT window displays.  
20. Select for Home, then press <Enter>.  
a
21. Under the Current Status page, type (store Config(1)) to save the changes you have just made to the con-  
1
figuration.  
This completes the initial configuration of the Model 6511RC. The next steps in configuration will be done  
using your web browser connected via Ethernet to the 6511RC.  
Using a browser to complete Model 6511RC configuration  
This section describes the following procedures:  
Displaying the Matrix Switch home page (see section “Displaying the Matrix Switch 6511RC web adminis-  
Defining the IP default gateway (see section “Configuring the default gateway” on page 51)  
Defining the system clocking parameters (see section “Configuring the system clocking parameters” on  
Defining the STM-1 Circuit parameters (see section “Configuring the SDH circuit parameters” on  
Enabling idle code generation for designated DS0 channels (see section “Configuring DS0 idle codes” on  
Defining DS0 mappings within the STM-1 link (see section “Selecting the SDH mapping path” on  
Displaying the Matrix Switch 6511RC web administration pages  
Do the following:  
1. Connect your PC’s Ethernet connection to the Ethernet LAN.  
2. Connect the 6511RC’s Matrix Switch 10/100 Ethernet port to the Ethernet LAN.  
3. At your PC, open a web browser session. In your browser’s URL/address field type the IP address of the  
Model 6511RC (for example, if the Model 6511RC’s IP address 123.124.221.10, you would type  
123.124.221.10 in the browser’s URL/address field). If you do not have an IP address in your TDAC, refer  
4. A login prompt will appear. In the username field type superuser then press <Tab> to move the cursor to the  
Password field. In the password field type superuser then press <Enter>.  
Using a browser to complete Model 6511RC configuration  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
5. The 3069RC Configuration Menu home page will appear (see figure 27).  
Figure 27. 6511RC Configuration Menu home page  
48  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
Home page overview  
The HOME window is divided into two panes: the Configuration Menu pane and the Configuration/Informa-  
tion pane (see figure 28). The Configuration Menu contains the links to the various Model 6511RC sub-  
systems, while in the Configuration/Information pane, you can view status and other information or make  
changes to the system configuration. Unlike the Configuration Menu pane, which appears the same no matter  
which subsystem page you may select, the Configuration/Information pane contents will change as you move  
from one subsystem page to another.  
Figure 28. HOME page window panes  
Using a browser to complete Model 6511RC configuration  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Figure 29. Operator Actions buttons  
From the Home page, the following actions can be performed:  
Record Current Configuration—clicking on this button (see figure 29) saves the current configuration  
from volatile DRAM memory to FLASH memory. Once the configuration is saved into FLASH memory,  
the configuration will not be lost even if the power is cycled on the 6511RC. Initially, changes made to the  
6511RC configuration are stored in volatile DRAM, enabling the user to set the box up with a working  
configuration before committing it to storage in FLASH. When you select Record Current Configuration,  
the 6511RC stores your changes to FLASH memory.  
Note If you want to save the configuration changes that you have made,  
you must click on Record Current Configuration, otherwise all con-  
figuration changes will be lost if the power to the Model 6511RC is  
turned off.  
Hard Reset—this button (see figure 29) causes the Model 6511RC to perform a cold restart. When you  
select Hard Reset, the Matrix Switch confirms that you want to execute this command. Then, the Matrix  
Switch will disconnect all current sessions, re-initialize the interfaces, and re-load configuration parameters  
from FLASH.  
Set Factory Default Configuration—this button (see figure 29) clears out the configuration in FLASH and  
loads the factory default parameters into FLASH memory. The factory default settings will not execute on  
the Model 6511RC until it is re-booted by doing a Hard Reset.  
Note Set Factory Default Configuration (figure 29) will delete the Model  
6511RC’s Ethernet IP address, any routing information, and any  
other site-specific configuration changes made for your particular  
installation. You will have to re-enter the Model 6511RC’s Ethernet  
IP address and netmask using the front-panel control port in order to  
gain access the HTTP/HTML Management pages again.  
50  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
Configuring the default gateway  
The default gateway IP address, if defined, is used solely for managing the 6511RC remotely via the Ethernet  
port. The 6511RC does not transmit or receive user data nor any other traffic via the default gateway IP  
address or the Ethernet port.  
Do the following to add the default gateway:  
1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the IP hyperlink to open the IP  
Overview page (see figure 30).  
Figure 30. IP Overview page  
2. Click the Routing Info hyperlink to open the IP Routing Overview page (figure 31).  
Figure 31. IP Routing Overview page  
Using a browser to complete Model 6511RC configuration  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
3. The Defined Routes table (see figure 32) will contain exactly one route, displayed in the first row of the  
table. The 6511RC created this route automatically when you defined the Ethernet IP address during Ini-  
tial Configuration, earlier in this chapter. That first row displays the route and netmask for the primary IP  
address you defined for the Matrix Switch Ethernet interfaces.  
Figure 32. Defined Routes table  
4. You will use the first row in the Define a New Route table (see figure 33) to define the default gateway. The  
Destination field contains the value 0.0.0.0. Because the netmask for the default gateway is implied by the  
Matrix Switch’s primary IP address, the Mask field does not display. In the Gateway field, enter your  
6511RC’s default gateway IP address.  
Figure 33. Define a New Route table  
5. Click the Define button (see figure 33) to activate the new default gateway address.  
Configuring the system clocking parameters  
In this section you will define the system clocking configuration for the Matrix Switch. Three issues pertain to  
system clocking:  
Module clocking mode—Will this Matrix Switch serve as a Master timing source for the other modules on  
the H.110 bus? (See section “Module clocking mode” for details.)  
Module clocking source—What clock pulse will the Matrix Switch use for primary reference and alternate  
(fallback) reference. (See section “Module clocking source and fallback” on page 53 for details.)  
Module clocking fallback—Will you enable or disable the clocking fallback feature in case the primary ref-  
erence fails? (See section “Module clocking source and fallback” on page 53 for details.)  
Module clocking mode  
Module clocking mode defines what role the Matrix Switch will assume on the H.110 bus with respect to sys-  
tem timing. You can select master(1), secondary(2), or slave(3) for the value of Clocking Mode. The master will  
drive the main reference clock for the chassis. Should the master fail, the secondary will drive the main refer-  
52  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
ence. Slaves will not drive any clock reference. Most often the 6511RC will be defined as the master(1), while  
most other modules in the chassis will be defined as slave(3).  
Module clocking source and fallback  
There are two module clocking source parameters, the primary reference and the fallback reference. Unless it fails  
or becomes disconnected, the primary reference provides the system clock for the 6511RC. Should this failure  
occur, the fallback reference will become the clocking source for the 6511RC’s system clock.You must choose  
one of the following values as the clocking source for each reference:  
An internal oscillator  
The STM-1 port  
The system clock provided by the H.110 clocking master, (i.e. another module in the chassis).  
The following examples illustrate how to define the system clocking parameters for two scenarios.  
Example 1. In this example, your 6511RC will be the clocking master for all other modules on the same  
H.110 bus. Your 6511RC will derive its own timing from its STM-1 port as the main reference, and from its  
internal oscillator as the fallback reference To define the system clocking parameters:  
.
1. Connect a STM-1 WAN line to the 6511RC’s STM-1 port.  
2. Click the System Clocking hyperlink on the 6511RC Configuration Menu (see figure 27 on page 48) to open  
the System Clocking Overview page (see figure 34).  
Figure 34. System Clocking Overview page, example 1  
3. For Module Clocking Mode, select master(1) from the drop-down menu.  
4. Under Module Clocking Source, for Primary Reference select wan(602) from the drop-down menu.  
5. For Fallback Reference select internal(200) from the drop-down menu.  
6. Under Module Clocking Fallback, for Fallback Feature Desired State, select enable(1).  
7. Click the Modify button.  
Using a browser to complete Model 6511RC configuration  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Example 2. For this example, another Matrix Switch is the chassis is the clocking master, providing the system  
clock for the chassis, and your 6511RC is a slave. Your 6511RC will derive its timing from the H.110 bus sys-  
tem clock as the main reference, and from its STM-1 port as the fallback reference To define the system clock-  
.
ing parameters:  
1. Connect a STM-1 WAN line to the 6511RC’s STM-1 port.  
2. Click the System Clocking hyperlink on the 6511RC Configuration Menu (see figure 27 on page 48) to open  
the System Clocking Overview page (see figure 35).  
Figure 35. System Clocking Configuration page, example 2  
3. For Module Clocking Mode, select slave(2) from the drop-down menu.  
4. Under Module Clocking Source, for Primary Reference select system(600) from the drop-down menu.  
5. For Fallback Reference select wan(602) from the drop-down menu.  
6. Under Module Clocking Fallback, for Fallback Feature Desired State, select enable(1).  
7. Click the Modify button.  
Configuring the SDH circuit parameters  
In order for the STM-1 link to function correctly, you must correctly define the values of certain configurable  
parameters that affect the SDH circuit. In order to configure the STM-1 link, you must first gather the follow-  
ing information:  
Which E1 mapping path—either AU3 or AU4—will be used within the STM-1 link  
Section trace message length  
The value of the JO byte for section trace messages  
Path-1 trace message length  
The value of the J1 byte for path-1 trace messages  
The value of path-1 signal label  
The E1 payload type, either asynchronous or byte synchronous  
54  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
Accessing the SDH circuit parameters  
To access the SDH circuit parameters:  
1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the SDH hyperlink to display the  
SDH Overview page (see figure 36)  
.
Figure 36. SDH Overview web management page  
2. On the SDH Overview page, click the Configuration... hyperlink to display the SDH Modify page (see  
Figure 37. SDH Modify page  
Using a browser to complete Model 6511RC configuration  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Configuring the SDH physical interface type  
Do the following to define the physical interface type providing the STM-1 link:  
1. In the SDH Physical Configuration section (see figure 38), select from the Physical Interface drop-down  
menu the value that corresponds to the physical cabling attached to your STM-1 interface ports. If you are  
using fiber-optic cable connected to the rear-card SC connectors, then select optical(0). If you are using  
coaxial cables connected to the rear-card BNC connectors, then select electrical(1).  
Figure 38. SDH Physical Configuration section  
2. Click the Submit button to activate your selection.  
Configuring the SDH interface parameters  
1. In the SDH Interface Configuration section (see figure 39), for Circuit Identifier, enter an optional alphanu-  
meric name for this STM-1 link.  
Figure 39. SDH Interface Configuration section  
2. If section trace is enabled in your connected SDH network, go to step 3. Otherwise, because section  
trace is disabled, for the Section Trace Monitor parameter, select sectionTraceDisable(0) from the drop-  
down menu, then go to step 7 to define the value of the SDH Payload Mapping parameter.  
3. Because section trace is enabled in your connected SDH network, for the Section Trace Monitor parame-  
ter, select sectionTraceEnable(1) from the drop-down menu.  
4. For the Section Trace message string, enter the alphanumeric string your connected SDH network uses for  
the section trace message string in the SDH frame.  
Note The Section Trace parameter only applies with 16-byte and 64-byte  
section trace messages. For 1-byte trace messages, the J0 byte parame-  
56  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
ter applies. When the section trace message length is defined to be  
one byte, the Matrix Switch will ignore the value of Section Trace.  
5. For Section Trace Msg Len, from the drop-down menu, select the value used by the SDH network your  
Matrix Switch is connected to: either 1, 16, or 64-byte trace messages.  
6. For Section Trace J0 Byte enter the value your connected SDH network uses for the J0 byte in the SDH  
frame.  
Note J0 applies only with 1-byte Section Trace Messages. For 16-byte and  
64-byte trace messages, the trace message string applies and the value of  
J0 is ignored.  
7. For SDH Payload Mapping, select the payload type corresponding to the way your connected SDH net-  
work maps the E1 payload into the SDH frame structure. Asynchronous E1 payload mapping is most  
common, so the factory default value on the Matrix Switch is stm1MappedAsynchE1(0). If your connected  
SDH network performs byte-synchronous E1 payload mapping, then select stm1MappedBytesynchE1(1)  
from the drop-down menu.  
8. For Tx Payload Scramble, if your SDH network expects to receive a scrambled payload select SDHScram-  
bleEnable(1) from the drop-down menu, otherwise select sdhScrambleDisable(0).  
9. For Rx Payload Scramble, if your SDH network transmits a scrambled payload select SDHScrambleEn-  
able(1) from the drop-down menu, otherwise select sdhScrambleDisable(0).  
10. For SDH Mapping, select the type of AU corresponding to the SDH multiplexing path you desire. To  
multiplex seven TUG-2s into an AU-3, select au3Mapper(0) (the factory default) from the drop-down  
menu. To multiplex three TUG-3s into an AU-4, select au4Mapper(1).  
11. Click the Modify button to save your work into operating memory (volatile DRAM) and activate the new  
parameter values.  
Configuring the SDH path trace parameters  
If you selected AU-4 mapping in the preceding procedure, the Matrix Switch will display one set of five parame-  
ters pertaining to Path 1. If you selected AU-3 mapping, the Matrix Switch will display three sets of five parame-  
ters each pertaining to Paths 1, 2, and 3. Do the following to define the values for the SDH path trace parameters:  
1. If path trace is enabled in your connected SDH network, go to step 2. Otherwise, because path trace is  
disabled, in the SDH trace parameters table (see figure 40), for Path-1 Trace Monitor, select pathTraceDis-  
able(0) from the drop-down menu. Refer to section “Configuring DS0 idle codes” on page 58.  
Figure 40. SDH Path Trace parameters  
Using a browser to complete Model 6511RC configuration  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
2. Because path trace is enabled in your connected SDH network, in the SDH trace parameters table (see  
figure 40 on page 57), for Path-1 Trace Monitor, select pathTraceEnable(1) from the drop-down menu.  
3. For Path-1 Trace message, enter the alphanumeric string your connected SDH network uses for the path-1  
trace message in the text box.  
Note The Path-1 Trace message parameter only applies with 16-byte and  
64-byte section trace messages. For 1-byte path trace messages, the J1  
byte parameter applies. When trace message length is defined to be  
one byte, the Matrix Switch will ignore the value of Path-1 Trace.  
4. For Path-1 Trace Msg Len, select the value corresponding to the trace message length your connected SDH  
network uses.  
5. For Path-1 Trace J1 Byte, enter the value your connected SDH network uses for the J1 byte in the  
SDH frame.  
Note J1 applies only with 1-byte path trace messages. For 16-byte and 64-  
byte trace messages, the trace message string is used and the value of  
J1 is ignored.  
6. For Path-1 Signal Label, enter the value your connected SDH network uses for the path-1 signal label in  
the SDH frame.  
7. If you have selected AU-3 mapping, repeat steps 1 through 6 to define values for the path-2 and path-3  
trace parameters.  
8. Click the Modify button to save your work into operating memory (volatile DRAM) and activate the new  
parameter values.  
Configuring DS0 idle codes  
If you want your Matrix Switch to encode vacant DS0 channels with the standard E1 idle code (the hexadeci-  
mal value 7E), you must follow the procedures below to designate which DS0 channels within the STM-1 sig-  
nal stream should be so encoded. Obviously, in order to correctly define the idle code configuration, you must  
know which DS0 channels in the SDH frame are expected to be idle. Defining the idle code configuration  
involves two steps: you must first access the DS0 Idle Code Configuration web management page, then use that  
page to select the idle DS0 channels from the STM-1 structure and designate them as idle.  
58  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
Accessing the idle code configuration  
Do the following to access the Matrix Switch’s idle code configuration:  
1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the E1 Link hyperlink to display the  
E1 Link page (see figure 41).  
Figure 41. E1 Link page  
2. To view all of the 63 E1s within the STM-1 link, first ensure that:  
tug3ALL(0) is selected next to the label TUG3  
tug2ALL(0) is selected next to the label TUG2  
then click the Submit Query button to display the next page showing E1 link status (see figure 42).  
Figure 42. Page showing E1 link status  
This page displays all 63 E1 links according to their position within the STM-1 mapping structure: each  
E1 resides within a tributary unit (TU), 3 TUs reside within each level-2 tributary unit group (TUG-2).  
The final level of multiplexing concentrates 7 TUG-2s within either a level-3 administrative unit group  
(AUG-3), or a level-3 tributary unit group (TUG-3). The TUG-3 then resides within a level-4 administra-  
tive unit group (AUG-4).  
Using a browser to complete Model 6511RC configuration  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
3. To access the DS0 Idle Code Configuration page for a selected E1, scroll right to view the DS0 configura-  
tion column, then click the blue diamond icon to display the SDH DS0 Idle Code Detail page (see  
Figure 43. SDH DS0 Idle Code Detail page  
Defining the DS0 idle code configuration  
The SDH DS0 Idle Code Detail page (see figure 43) displays a table for a selected E1, specified by the page title,  
within the STM-1 link. The table displays the value of the idle code parameter for each of the 32 DS0s within  
the specified E1 stream. To define the idle code configuration for the selected E1:  
1. Find the DS0 number for which you want the Matrix Switch to generate an idle code.  
2. Select the value enable(1) from the adjacent drop-down menu.  
3. Repeat steps 1 and 2 for each DS0 for which you want to enable idle code generation.  
4. Click the Modify button to save your work into operating memory (volatile DRAM) and activate your  
changes.  
To complete the DS0 idle code configuration for the entire STM-1 link, you will ned to repeat the above pro-  
cedures for each E1 that you want to enable DS0 idle code generation for.  
Selecting the SDH mapping path  
The Matrix Switch offers two options for the SDH mapping path: you can select the mapping path terminat-  
ing with TUG-2 and AU-3 or TUG-3 and AU-4.  
60  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
The mapping path you select will determine which parameter fields the 6511RC will display on the DS0 Map-  
ping Overview page. You have already selected an SDH mapping type, but you may wish to double-check this  
value before mapping any DS0s, by doing the following:  
1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the SDH hyperlink to open the SDH  
overview page (see figure 44).  
Figure 44. SDH Overview page  
2. At the top of the SDH Overview page, click the Configuration hyperlink to open the SDH Modify page (see  
Figure 45. SDH Modify page  
Using a browser to complete Model 6511RC configuration  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
3. Scroll down to the SDH mapping parameter and select the appropriate mapping path from the drop-down  
menu. Select au3Mapper(0) or au4Mapper(1). To multiplex seven TUG-2s into an AU-3, select  
au3Mapper(0) (the factory default) from the drop-down menu. To multiplex three TUG-3s into an AU-4,  
select au4Mapper(1).  
4. Click the Submit button to save changes.  
You are now ready to define DS0 mappings.  
Defining DS0 mappings  
In order for the STM-1 link to carry traffic through the Matrix Switch to and from the ForeFront system, you  
must define a set of DS0 mappings (correlations). You will define mappings between the full-duplex DS0s  
within the STM-1 link and the simplex DS0s within the H.110 bus. While it is not necessary to define a map-  
ping for every DS0 in the SDH link, only the mapped DS0s will carry user data. Unmapped DS0s may be con-  
figured to carry an idle code. Otherwise, unmapped DS0s will carry a random bit stream.  
For each DS0 Mapping you define, you will create a correlation between a communications channel in the  
STM-1 link and a communications channel within the ForeFront chassis mid-plane. Each STM-1 channel  
consists of a set of full-duplex DS0s. Each midplane channel consists of two simplex sub-channels, transmitted  
and received. Each sub-channel consists of a set of simplex DS0s. You will define each STM-1 channel and  
each mid-plane sub-channel by specifying one or more timeslot numbers up to a maximum of 32 timeslots per  
channel. For a STM-1channel you will select up to 32 timeslot numbers from the range numbered 1 to 32. For  
a mid-plane channel you will select up to 32 timeslots from the range numbered 1 to 128.  
On the STM-1 side, there are 63 E1 signal streams, each comprising 32 DS0s. Within an E1, each DS0 is a  
full-duplex channel, comprising a transmitted and a received signal stream. The STM-1 link comprises 2016  
full-duplex DS0s.  
On the mid-plane side, there are 4096 simplex DS0s within the H.110 bus, organized into 32 ports. Each  
H.110 port comprises 128 DS0s. Within the H.110 bus, each DS0 is a simplex signal stream, which the  
H.110 bus can either transmit or receive. You will define the direction of a mid-plane DS0 during the mapping  
process as either transmitting to the H.110 bus or receiving from the H.110 bus. The H.110 bus provides  
4096 simplex DS0s.  
When entering E1 and H.110 timeslot numbers, you must define the same number of timeslots on the SDH  
and mid-plane sides of the mapping. The timeslots are defined by entering a text string that represents the  
timeslot numbers.  
The following notation should be used for assigning timeslots:  
dash: (-), e.g., 1-4  
comma: (,), e.g., 1,4,9  
combo: 1-2,3,6-7  
62  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
The Matrix Switch offers two formats for defining DS0 mappings:  
E1 port format—You will identify the 63 E1 signal streams within the STM-1 link using E1 port numbers  
1-63. Those with little to moderate experience working with SDH network architecture will most likely  
find E1 format to be the simplest and most straightforward method for defining DS0 mappings. Refer to  
TU format—You will identify an E1 signal stream according to its location within the STM-1 hierarchy,  
using the TU-12 number and TUG-2 number within an AUG-3 or within a TUG-3/AUG-4. Experienced  
SDH engineers with a clear understanding of STM-1 architecture will most likely prefer to use TU format  
to define DS0 mappings. Refer to section “Defining DS0 mappings using TU format” on page 69.  
Figure 46 shows the position of each E1 port number within the STM-1 frame.  
Figure 46. E1 Port numbers located within the STM-1 frame structure  
The following sections describe how to define DS0 mappings.  
Using a browser to complete Model 6511RC configuration  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Figure 47. DS0 Mapping Overview page  
Defining DS0 mappings using E1 port format  
For those with little to moderate experience in working with SDH network architecture, E1 format will most  
likely the simplest and most straightforward method for defining DS0 mappings. To define a DS0 mapping by  
E1 number, do the following:  
1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the DS0 Mapping hyperlink to dis-  
play the DS0 Mapping Overview page (see figure 47).  
2. For the Display Option parameter, ensure that displayLongForm(0) is selected from the drop-down menu  
(figure 47), then click the Modify button.  
3. For the E1 Input Format parameter, select e1PortFormat(1) from the drop down menu, then click the adja-  
cent Modify button.  
4. In the Define a Mapping section, for E1 number, select the appropriate E1 port number from the drop-  
down menu.  
5. For E1 Slots, type the timeslot numbers you wish to map to the H.110 bus.  
When entering E1 and H.110 timeslot numbers you must define the same number of timeslots on the  
SDH and mid-plane sides of the mapping. The timeslots are defined by entering a text string that repre-  
sents the timeslot numbers.  
64  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
The following notation should be used for assigning timeslots:  
– dash: (-), e.g., 1 – 4  
– comma: (,), e.g., 1,4,9  
– combo: 1-2,3,6-7  
At this point you have defined the SDH channel composed of a selected E1 signal stream and a set of  
timeslots within that E1. Now you must define the mid-plane channel to be correlated with the  
SDH channel.  
6. In the first row, labeled to H110(5), for the H.110 number, select the appropriate H.110 port number  
from the drop-down menu  
7. In the first row, labeled toH110(5), for H.110 slots, enter the timeslot numbers you wish to map to the  
H.110 bus (from the E1).  
8. In the second row, labeled fromH110(6), select the appropriate H.110 port number from the drop-  
down menu  
9. In the second row, labeled fromH110(6), for H.110 slots, enter the timeslot numbers you wish to map  
from the H.110 bus (to the E1).  
10. Click the Define button. The new mapping will appear at the bottom of the page in the Defined  
Mappings table.  
11. Examine the Defined Mappings table to verify that your new mapping appears and was correctly entered  
and recorded.  
Examples for configuring DS0 mappings.  
Three examples are provided:  
Example 1—For E1 port number 1:  
- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 1-32  
- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 33-64  
Example 2—For E1 port number 2:  
- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 65-96  
- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 97-128  
Example 3—For E1 port number 7  
- map all 32 timeslots of the E1 received signal to H.110 port 4 timeslots 1-32  
- map all 32 timeslots of the E1 transmitted signal from H.110 port 4 timeslots 33-64  
Using a browser to complete Model 6511RC configuration  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Example 1  
Map E1 Port 1 received, timeslots 1-32 to H.110 Port 1 timeslots 1-32.  
Map E1 Port 1 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 33-64.  
Solution:  
1. Under E1 Number, select port1(1) from the drop-down menu (see figure 48).  
2. Under E1 Slots, enter 1-32 in the text box.  
3. For toH110(5), under H.110 Number, select port1(1) from the drop-down menu.  
4. For toH110(5), under H.110 slots, enter 1-32 in the text box.  
5. For fromH110(5), under H.110 Number, select port1(1) from the drop-down menu.  
6. For fromH110(5), under H.110 slots, enter 33-64 in the text box.  
Figure 48. Define a mapping table for Example 1  
7. Click the Define button.  
8. Verify your new mapping appears in the Defined Mappings table (see figure 49).  
Figure 49. Defined Mappings table for example 1  
9. Examine the new mapping to verify that it was entered and recorded correctly.  
You have completed the DS0 mapping procedure for example 1.  
66  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
Example 2  
Map E1 Port 2 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.  
Map E1 Port 2 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 97-128.  
Solution:  
1. Under E1 Number, select port2(2) from the drop-down menu (see figure 50).  
2. Under E1 Slots, enter 1-32 in the text box.  
3. For toH110(5), under H.110 Number, select port1(1) from the drop-down menu.  
4. For toH110(5), under H.110 slots, enter 65-96 in the text box.  
5. For fromH110(5), under H.110 Number, select port1(1) from the drop-down menu.  
6. For fromH110(5), under H.110 slots, enter 97-128 in the text box.  
Figure 50. Define a Mapping table for example 2  
7. Click the Define button.  
8. Verify your new mapping appears in the Defined Mappings table (see figure 51).  
Figure 51. Defined Mappings table for example 2  
9. Examine the new mapping to verify that it was entered and recorded correctly.  
You have completed the configuration for example 2.  
Using a browser to complete Model 6511RC configuration  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Example 3  
Map E1 Port 7 received, timeslots 1-32 to H.110 Port 4 timeslots 1-32.  
Map E1 Port 7 transmitted, timeslots 1-32 from H.110 Port 4 timeslots 33-64.  
Solution:  
1. Under E1 Number, select port7(7) from the drop-down menu (see figure 52).  
2. Under E1 Slots, enter 1-32 in the text box.  
3. For toH110(5), under H.110 Number, select port4(4) from the drop-down menu.  
4. For toH110(5), under H.110 slots, enter 1-32 in the text box.  
5. For fromH110(5), under H.110 Number, select port4(4) from the drop-down menu.  
6. For fromH110(5), under H.110 slots, enter 33-64 in the text box.  
Figure 52. Define a Mapping table for example 3  
7. Click the Define button.  
8. Verify your new mapping appears in the Defined Mappings table (see figure 53).  
Figure 53. Defined Mappings table for example 3  
9. Examine the new mapping to verify that it was entered and recorded correctly.  
You have completed the configuration for example 3.  
68  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
Defining DS0 mappings using TU format  
Experienced SDH engineers with a solid understanding of STM-1 architecture will most likely prefer to use  
TU format to define DS0 mappings. To define a DS0 mapping using TU format, do the following:  
1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the DS0 Mapping hyperlink to dis-  
play the DS0 Mapping Overview page (see figure 54).  
2. For the Display Option parameter, verify that displayLongForm(0) is selected from the drop-down menu.  
3. For the E1 Input Format parameter, select tuFormat(0) from the dropdown menu.  
4. Click the Modify button to save changes.  
Figure 54. DS0 Mapping Overview page with TU format selected  
Using a browser to complete Model 6511RC configuration  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Figure 55. E1 port numbers located within the STM-1 frame structure  
5. The first three parameters in the Define a Mapping section (see figure 54 on page 69) specify an E1 signal  
stream within the STM-1 link. The STM-1 link contains either three TUG-3s or three AU-3s (see  
figure 55). In the Define a Mapping section, the first parameter name will vary depending on the mapping  
path you selected on the SDH configuration page. If you selected au3Mapper(0) then Au-3 will be dis-  
played. If you selected au4Mapper(1) then Tug-3 will be displayed. To define the value of the first map-  
ping parameter, select from the drop-down menu the AU-3 or TUG-3 number that contains the E1 you  
wish to map. The options for the value of AU-3 are:  
– au3-1(1)  
– au3-2(2)  
– au3-3(3)  
The options for the value of TUG-3 are:  
– tug3-1(1)  
– tug3-2(2)  
– tug3-3(3)  
6. Each AU-4 or TUG-3 contains seven TUG-2s. To define the value of the TUG-2 parameter, select from  
the drop-down menu the TUG-2 number that contains the E1 you wish to map. The options for the value  
of TUG-2 are:  
– tug2-1(1)  
– tug2-2(2)  
– tug2-3(3)  
– tug2-4(4)  
– tug2-5(5)  
70  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
– tug2-6(6)  
– tug2-7(7)  
7. Each TUG-2 contains three TU-12s (which in turn contain one E1 each). To define the value of the TU-  
12 parameter, select one of the following values from the drop-down menu:  
– tu12-1(1)  
– tu12-2(2)  
– tu12-3(3)  
8. The three parameters you defined above specify a selected E1 signal stream within the STM-1 link. For E1  
Slots, enter the timeslot numbers within the selected E1 link that you wish to map to the H.110 bus.  
When entering E1 and H.110 timeslot numbers you must define the same number of timeslots on the  
SDH and mid-plane sides of the mapping. The timeslots are defined by entering a text string that repre-  
sents the timeslot numbers.  
The following notation should be used for assigning timeslots:  
– dash: (-), e.g., 1–4  
– comma: (,), e.g., 1,4,9  
– combo: 1-2,3,6-7  
At this point you have defined the SDH channel composed of a selected E1 signal stream and a set of  
timeslots within that E1. Now you must define the mid-plane channel to be correlated with the  
SDH channel.  
9. Under the heading Mid-plane Channel, in the first row, labeled to H110(5), for H.110 number, select your  
desired H.110 port number from the drop-down menu.  
10. In the first row, labeled toH110(5), for H.110 slots, enter the timeslot numbers you wish to map to the  
H.110 bus (from the E1).  
11. In the second row, labeled fromH110(6), select your desired H.110 port number from the drop-  
down menu  
12. In the second row, labeled fromH110(6), for H.110 slots, enter the timeslot numbers you wish to map  
from the H.110 bus (to the E1).  
13. Click the Define button. The new mapping will appear at the bottom of the page in the Defined  
Mappings table.  
14. Examine the Defined Mappings table to verify that the new mapping appears and was correctly entered  
and recorded.  
Using a browser to complete Model 6511RC configuration  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Examples for configuring DS0 mappings.  
Three examples are provided:  
Example 1—For the E1 located in TUG-3 or AU-3 number 1, TUG-2 number 1, TU-12 number 1  
(Matrix Switch E1 port number 1):  
- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 1-32  
- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 33-64  
Example 2—For the E1 located in TUG-3 or AU-3 number 2, TUG-2 number 1, TU-12 number 1  
(Matrix Switch E1 port number 2):  
- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 65-96  
- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 97-128  
Example 3—For the E1 located in TUG-3 or AU-3 number 1, TUG-2 number 1, TU-12 number 3  
(Matrix Switch E1 port number 7)  
- map all 32 timeslots of the E1 received signal to H.110 port 4 timeslots 1-32  
- map all 32 timeslots of the E1 transmitted signal from H.110 port 4 timeslots 33-64  
Example 1  
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 received, timeslots 1-32 to H.110 Port 1 timeslots 1-32.  
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 transmitted, timeslots 1-32 from H.110 Port  
1 timeslots 33-64.  
Solution:  
1. For the value of the first parameter under SDH Channel, select TUG3-1(1) or AU3-1(1) from the drop-  
down menu.  
2. For the value of TUG-2 select TUG2-1(1) from the drop-down menu.  
3. For the value of TU-12 select TU12-1(1) from the drop-down menu.  
4. For the value of E1 Slots, enter 1-32 in the text box.  
5. For toH110(5), under H.110 Number, select port1(1) from the drop-down menu.  
6. For toH110(5), under H.110 slots, enter 1-32 in the text box.  
7. For fromH110(5), under H.110 Number, select port1(1) from the drop-down menu.  
8. For fromH110(5), under H.110 slots, enter 33-64 in the text box.  
9. Click the Define button.  
10. Verify that your new mapping appears in the Defined Mappings table.  
11. Examine the new mapping to ensure it was entered and recorded correctly.  
You have completed the DS0 mapping procedure for example 1.  
72  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
Example 2  
Map TUG-3 or AU-3 no. 2, TUG-2 no. 1, TU-12 no. 1 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.  
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 transmitted, timeslots 1-32 from H.110 Port  
1 timeslots 97-128.  
Solution:  
1. For the value of the first parameter under SDH Channel, select either TUG3-2(2) or AU3-2(2) from the  
drop-down menu.  
2. For the value of TUG-2 select TUG2-1(1) from the drop-down menu.  
3. For the value of TU-12 select TU12-1(1) from the drop-down menu.  
4. Under E1 Slots, enter 1-32 in the text box.  
5. For toH110(5), under H.110 Number, select port1(1) from the drop-down menu.  
6. For toH110(5), under H.110 slots, enter 65-96 in the text box.  
7. For fromH110(5), under H.110 Number, select port1(1) from the drop-down menu.  
8. For fromH110(5), under H.110 slots, enter 97-128 in the text box.  
9. Click the Define button.  
10. Verify your new mapping appears in the Defined Mappings table.  
11. Examine the new mapping to ensure it was entered and recorded correctly.  
You have completed the configuration for example 2.  
Example 3  
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 3 received, timeslots 1 - 32 to H.110 Port 4 timeslots 1-  
32.  
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 3 transmitted, timeslots 1 - 32 from H.110 Port  
4 timeslots 33- 64.  
Solution:  
1. For the value of the first parameter under SDH Channel, select either TUG3-1(1) or AU3-1(1) from the  
drop-down menu.  
2. For the value of TUG-2 select TUG2-1(1) from the drop-down menu.  
3. For the value of TU-12 select TU12-3(3) from the drop-down menu.  
4. Under E1 Slots, enter 1-32 in the text box.  
5. For toH110(5), under H.110 Number, select port4(4) from the drop-down menu.  
6. For toH110(5), under H.110 slots, enter 1-32 in the text box.  
7. For fromH110(5), under H.110 Number, select port4(4) from the drop-down menu.  
8. For fromH110(5), under H.110 slots, enter 33-64 in the text box.  
Using a browser to complete Model 6511RC configuration  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
9. Click the Define button.  
10. Verify your new mapping appears in the Defined Mappings table.  
11. Examine the new mapping to ensure it was entered and recorded correctly.  
You have completed the configuration for example 3.  
Saving your configuration  
At this point you have completed the basic configuration of your Matrix Switch for operation. To save your  
configuration settings in non-volatile RAM, do the following:  
1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the HOME hyperlink to open the  
6511RC Web Management Home page (see figure 56).  
Figure 56. 6511RC Home page  
2. Under Operator Actions Click the Record Current Configuration button (see figure 56).  
Note All configuration settings will be lost unless you click on the  
Record Current Configuration button before you power down  
or reset the Matrix Switch.  
74  
Using a browser to complete Model 6511RC configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
Backing up your configuration parameters  
The 6511RC Matrix Switch provides Import/Export functions that enable you to back up (export) and restore  
(import) your Matrix Switch’s configuration parameters against possible failure. Should your Matrix Switch  
ever need replacing, a previously saved copy of your (exported) configuration file can quickly be loaded  
(imported) into a replacement Matrix Switch.  
Note Import/Export functions require superuser access privileges.  
Note The parameters that will be exported are the power-up settings as they  
are stored in flash memory and may not be the current operating  
parameters. To ensure that you export the most current parameters,  
go to HOME, then under Operator Actions, click on the Record Cur-  
rent Configuration button.  
To import or export a configuration, do the following:  
1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the Import/Export hyperlink to dis-  
play the Import/Export page (see figure 57).  
Figure 57. Import/Export page  
Backing up your configuration parameters  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
Backing up the configuration store in flash memory  
To make a back-up copy of the configuration file currently stored in your Matrix Switch’s flash memory:  
1. On the Import/Export page (see figure 57 on page 75) click the Export Flash... hyperlink. The Matrix  
Switch will get the configuration file currently stored in your Matrix Switch’s flash memory and display it  
in your browser (see figure 58)  
Figure 58. Example Matrix Switch flash memory configuration file displayed in a browser  
76  
Backing up your configuration parameters  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
3 • Configuring the Matrix Switch for operation  
2. To save the displayed data as a text file, use your browser’s Save function (see figure 59). Using Netscape  
or Internet Explorer, for example, do the following:  
– Click the File menu.  
– Click Save As. A dialog box will appear. Use the dialog to save the data displayed on your browser (your  
Matrix Switch configuration parameters) to a text file.  
– Select the folder in which you want to store the file.  
– Type a file name.  
– Click Save.  
Figure 59. Saving the access server flash memory configuration data as a text file  
Completing the installation  
This section verifies that the Model 6511RC is fully operational.  
1. Perform a hard reset as follows:  
– On the configuration menu, click the HOME hyperlink to display the Matrix Switch Home Page.  
– Scroll down to Operator Actions buttons.  
– Click the Hard Reset button.  
2. Wait about ten seconds for the Matrix Switch to fully resume normal operation.  
3. Verify the green POWER LED is lit. If the POWER LED is flashing green, refer to chapter 5, “Trouble-  
4. Verify that green SYSTEM LED is flashing to indicate the Model 6511RC system is operating normally.  
Completing the installation  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3 • Configuring the Matrix Switch for operation  
Model 6511RC User Manual  
5. Verify that the green WAN LED is illuminated, indicating that the Model 6511RCSTM-1 port is acti-  
vated, is synchronized with the SDH network, and operating normally.  
Note If the Matrix Switch does not behave as described, the most likely  
cause is that the Matrix Switch SDH parameters values for the STM-  
1 link do not match those of the connected SDH network. To resolve  
this problem, double check the parameters on the Matrix Switch  
SDH Configuration page against those of the Connected SDH net-  
work, and correct any incorrect values.  
6. There are three LEDs that indicate status for the Matrix Switch Ethernet subsystem. For information  
about interpreting the three Ethernet status LEDs, see table 3 on page 27.  
Congratulations! Your Matrix Switch is now installed. If you require further information about configuring  
your Matrix Switch settings, refer to the Model 6511RC Matrix Switch Administrator’s Reference Guide available  
online at www.patton.com/manuals/6511RC-arg.pdf.  
Note For information on activating and de-activating your Model 6511RC  
Matrix Switch, refer to chapter 4, “Operation and shutdown” on  
78  
Completing the installation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4 Operation and shutdown  
Chapter contents  
Introduction..........................................................................................................................................................80  
Activating the Model 6511RC...............................................................................................................................80  
De-activating the Model 6511RC .........................................................................................................................80  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4 • Operation and shutdown  
Model 6511RC User Manual  
Introduction  
This chapter describes how to start up and power down the Model 6511RC.  
Activating the Model 6511RC  
The Model 6511RC is activated by completing the procedures in chapter 2, “Hardware installation” on  
refer to the procedures in those chapters.  
The Model 6511RC is designed for unattended operation. Once the Model 6511RC has been installed and  
configured, no further operator action is required under normal conditions.  
De-activating the Model 6511RC  
Perform the following procedure to deactivate the Model 6511RC.  
Note Be sure to wear an anti-static strap to prevent electrostatic damage to  
the blade.  
1. Simultaneously press both red buttons on the front-panel handles of the 6511RC to unlock the handles  
and prepare the module for removal.  
2. Simultaneously press both black handles outward and away from the center of the module to unseat the  
6511RC from the mid-plane connectors.  
3. Pull the handles to completely remove the Model 6511RC from the rack chassis. Place the module on an  
anti-static surface.  
4. Repeat the above procedure to remove the rear module from the rack chassis. Place the blade on an anti-  
static surface.  
80  
Introduction  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 5 Troubleshooting and maintenance  
Chapter contents  
Introduction..........................................................................................................................................................82  
Troubleshooting during initial deployment ...........................................................................................................82  
General fault analysis.............................................................................................................................................83  
Matrix Switch test tools.........................................................................................................................................86  
Loopback test modes for the STM-1 port .......................................................................................................86  
Facility Loop [sonetFacilityLoop(1)] .........................................................................................................87  
Terminal loop [sonetTerminalLoop(2)] ....................................................................................................88  
Other Loop [sonetOtherLoop(3)] .............................................................................................................90  
SDH section trace and path trace ....................................................................................................................90  
Sections and paths .....................................................................................................................................91  
Section trace ..............................................................................................................................................91  
Path trace ..................................................................................................................................................92  
Number of paths per frame .......................................................................................................................93  
Periodic maintenance ............................................................................................................................................94  
Calibration ......................................................................................................................................................94  
Maintenance..........................................................................................................................................................94  
Replacing the Model 6511RC .........................................................................................................................94  
Exporting the current Model 6511RC configuration ................................................................................94  
Removing the defective Model 6511RC ....................................................................................................97  
Installing the replacement Model 6511RC ................................................................................................98  
Importing a saved configuration ................................................................................................................98  
Completing the installation .......................................................................................................................99  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
Introduction  
This chapter provides guidance to assist you when performing troubleshooting and fault analysis as a Matrix  
Switch operator. Should you require more information or technical assistance, refer to chapter 6, “Contacting  
Troubleshooting during initial deployment  
The following table (see table 5) describes the symptoms for system faults that commonly occur when the  
Matrix Switch is first deployed, along with suggested remedies for each fault.  
Note The symptoms listed in table 5 apply to single-fault scenarios involv-  
ing the Model 6511RC. Performing the recommended corrective  
action will solve such single points of failure, but may not correct any  
additional faults that might co-exist. If you are unable to correct a  
failure in your Matrix Switch, refer to chapter 6, “Contacting Patton  
Note When removing the 6511RC from the chassis, follow the procedures  
Note When re-inserting the 6511RC into the chassis, please follow the pro-  
Table 5. Symptoms  
Problem  
Corrective Action  
POWER LED (green)  
is extinguished  
To verify that power is being supplied to the Model 6511RC via the CPCI chassis  
power bus: verify that at least one chassis power supply module is installed in the  
chassis and functioning normally.  
POWER LED (green) is The 6511RC has detected a power failure on a power bus. There may be a prob-  
flashing  
lem with the CPCI chassis power system which feeds the Model 6511RC such as a  
failed power supply module in the chassis. The Model 6511RC will function nor-  
mally with one power supply. Inspect the power supplies in the CPCI chassis to  
identify and replace the failed power supply module. If no failed power supply is  
found, or if the POWER LED continues flashing, contact Patton Technical Support to  
determine if the Matrix Switch should be replaced.  
CPU FAIL LED (red) is lit CPU is unable to load the software from FLASH to RAM for operation. As soon as  
possible, remove the Model 6511RC from the CPCI chassis, wait 30 seconds, then  
re-insert the Model 6511RC into the CPCI chassis and see if the problem disap-  
pears. If the CPU FAIL LED remains lit after the Model 6511RC completes the  
power-up cycle, contact Patton Technical Support to determine if the Matrix Switch  
needs to be replaced.  
ALARM LED (yellow) is Indicates The 6511RC has detected a minor or major alarm condition. Examine  
lit or flashing  
the Alarm System Overview web management page to determine exactly which  
alarm(s) is(are) active.  
82  
Introduction  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
Table 5. Symptoms (Continued)  
Corrective Action  
Problem  
SYSTEM LED (green) is The Model 6511RC is not functioning properly.  
not flashing  
As soon as possible, force a module power cycle as follows:  
1)Wearing an antistatic strap, simultaneously press both red buttons on the front-  
panel handles of the 6511RC to unlock the handles and prepare the module for  
removal.  
2)Simultaneously press both black handles outward and away from the center of  
the module to unseat the 6511RC from the mid-plane connectors.  
3) Wait 10 seconds.  
4)Holding the module by the two black handles, very carefully push the module  
gently and firmly into the chassis until it is reseated against the midplane.  
5)Press the black handle so that they click and lock closed.  
Once the Matrix Switch has resumed operation re-inspect the SYSTEM LED. If the  
SYSTEM LED does not begin flashing after completing the power-up cycle, contact  
Patton Technical Support to determine if the Matrix Switch should be replaced.  
General fault analysis  
The following procedures outline steps you should follow when troubleshooting a Model 6511RC malfunction.  
1. If possible, talk to the person who reported the problem and obtain a detailed description of the symp-  
toms. Create a written trouble report listing all the symptoms observed, including a complete description  
of the status for each LED indicator.  
2. LED Status Indications and Recommended actions, table 6 provides information on interpreting LED status  
indicators along with recommended actions in response to each LED status indication. To correct the  
problem with your Matrix Switch, compare each LED status in your trouble report with the information  
in the table, and follow the recommend action for each LED.  
Table 6. LED status indications and recommended actions  
LED  
Location Color Status  
Meaning  
POWER  
Front  
panel  
Green On solid Power is being applied. No action recommended.  
Flashing The 6511RC has detected a power failure on a power bus. There may  
be a problem with the CPCI power supply system such as a failed power  
supply module in the chassis. The Model 6511RC will function normally  
with one power supply.  
Inspect the power supplies in the CPCI chassis to identify and replace the  
failed power supply module. If the POWER LED continues flashing when  
all chassis power supplies are functional, contact Patton Technical Sup-  
port to determine if the Matrix Switch should be replaced.  
Off  
No input power is being applied. Verify that at least one chassis power  
supply module is installed in the chassis and functioning normally.  
General fault analysis  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
Table 6. LED status indications and recommended actions (Continued)  
Location Color Status Meaning  
LED  
CPU FAIL  
Front  
panel  
Red On solid CPU is unable to load the software from FLASH to RAM for operation.  
As soon as possible, remove the Model 6511RC from the CPCI chassis,  
wait 30 seconds, then re-insert the Model 6511RC into the CPCI chassis  
and see if the problem disappears.  
If the CPU FAIL LED remains lit after the Model 6511RC completes the  
power-up cycle, contact Patton Technical Support to determine if the  
Matrix Switch needs to be replaced.  
Off  
The CPU is operating normally. No action recommended.  
ALARM  
Front  
panel  
Red On solid A minor alarm condition has been detected.  
Flashing A major alarm condition has been detected.  
Off  
The Model 6511RC is operating normally. No action recommended.  
SYSTEM  
Front  
panel  
Green Flashing The Model 6511RC is operating normally. No action recommended.  
Off  
or  
The Model 6511RC is not functioning properly.  
As soon as possible, remove the Model 6511RC from the CPCI chassis,  
wait 10 seconds, then re-insert the Model 6511RC into the CPCI chassis  
and see if the problem disappears.  
On solid  
Once the Matrix Switch has resumed operation re-inspect the SYSTEM  
LED. If the SYSTEM LED does not begin flashing after completing the  
power-up cycle, contact Patton Technical Support to determine if the  
Matrix Switch should be replaced.  
ENET(NOD  
E)  
Front  
panel  
Green Flash- Indicates there is Ethernet frame activity on one or more of the 6511RC’s  
ing or Ethernet interfaces, including the two rear-panel 10/100/1000 ports,  
On solid the front -panel 10/100 port, and the packet--switched PICMG 2.16  
bus. No action recommended  
Off  
Indicates NO Ethernet frame activity detected on any of the  
6511RC’s Ethernet interfaces, including the PICMG 2.16 bus.  
Verify that an Ethernet cable is plugged into the hub, switch, or work-  
station and the 10/100 Ethernet port on the front panel of the Model  
6511RC.  
Verify that the hub, switch, or workstation is powered on.  
Verify that the correct straight-through or cross-over cable is being  
used, depending on whether you are connecting to a workstation  
(PC), hub, or switch.  
Replace the cable. If the problem still exists, contact Patton Technical  
Support to determine if the Matrix Switch should be replaced.  
CLK  
SOURCE  
Front  
panel  
Green On solid The 6511RC is set as the Master Clock source.  
No action recommended.  
Flashing The 6511RC is set as the secondary clock source.  
No action recommended.  
Off  
The 6511RC is set as the slave, getting its clock from the H.110 Bus.  
No action recommended.  
84  
General fault analysis  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
Meaning  
Table 6. LED status indications and recommended actions (Continued)  
LED  
Location Color Status  
CLK ERROR  
Front  
panel  
Yellow On solid  
Primary Reference clocking source has been lost and the 6511RC is  
using the Secondary Reference as its clocking source. Matrix Switch  
operation should continue unimpaired.  
Visit the System Clocking Overview page and examine the current  
clocking configuration and status.  
Use the clocking configuration and status information to determine  
the appropriate course of action to restore the Primary Reference  
clock source to operation.  
Flashing  
Master Clock source and the Secondary Clock source have been lost  
and the 6511RC is using its internal crystal for its clock. Matrix Switch  
operation should continue unimpaired.  
Visit the System Clocking Overview page to examine the current  
clocking configuration and status.  
Use the information in determined the appropriate course of action to  
restore the Primary Reference to operation.  
Off  
No clock errors currently detected. No action recommended.  
TEST MODE  
WANa  
Front  
Green On solid The STM-1 port is currently operating in some test mode.  
panel  
No action recommended.  
Off  
None of the G.SHDSL ports is operating in test mode.  
No action recommended.  
Front  
Panel  
Green On solid Indicates the STM-1 port is activated, synched, and operating normally.  
No action recommended.  
Single Indicates that the Model 6511RC is detecting the SDH network, but is  
Flash unable to synchronize with it.  
Verify the STM-1 cables are fully and correctly connected.  
Examine the SDH Configuration page and ensure each parameter  
value matches the corresponding value in the connected SDH net-  
work.  
Off  
Indicates rear module not present or STM-1 port is not configured.  
Ensure rear module is incorrectly installed; install if absent.  
Examine the SDH Configuration page and ensure each parameter  
value matches the corresponding value in the connected SDH net-  
work.  
ENET  
(SWITCH)  
Front  
Panel  
Green Flashing Indicates there is Ethernet frame activity on at least one of the eight PICMG  
or  
2.16 connections to other blades on the PSB bus.No action recommended.  
On solid  
Off  
Indicates no Ethernet frame activity detected on the PICMG 2.16 bus.  
No action recommended.  
ENET(REAR)  
Front  
Panel  
Green Flashing Indicates Ethernet frame activity on one or both of the 10/100/1000  
or  
Ethernet ports. No action recommended  
On solid  
General fault analysis  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
Table 6. LED status indications and recommended actions (Continued)  
LED  
Location Color Status  
Meaning  
Off  
There is NO Ethernet frame activity on either of the 10/100/1000  
Ethernet ports. No action recommended  
READY  
Front  
panel  
Blue  
On  
Off  
Indicates module is ready for removal from cPCI chassis.  
Indicates module NOT ready for removal from cPCI chassis.  
Do not remove card from chassis.  
ALARM  
Rear  
blade  
Yellow Onsolid A minor alarm condition has been detected.  
Flashing A major alarm condition has been detected.  
Off  
On  
Off  
The Model 6511RC is operating normally. No action recommended.  
Card ready for removal from cPCI chassis.  
Card not ready for removal from cPCI chassis.  
Do not remove card from chassis.  
READY  
Rear  
blade  
Blue  
ON LINE  
On  
Off  
Green On  
Reserved for future use  
Reserved for future use  
Ethernet Link is established  
10/100  
ENET  
Front  
Panel  
Integrated  
LEDs on RJ-  
45 connec-  
tor  
Off  
Yellow On  
Off  
No Ethernet link is established  
Flashes to indicates Ethernet frame activity on this port  
Indicates no Ethernet frame activity on this port  
READY  
Blue  
On  
Off  
Card ready for removal from cPCI chassis.  
Card not ready for removal from cPCI chassis.  
a. This LED provides status indications for the STM-1 WAN link established via the optical or electrical ports on  
the Rear Module of the 6511RC  
Matrix Switch test tools  
For the purpose of testing and troubleshooting the STM-1 link, the DS0 Mapping definitions, and H.110 bus  
connectivity, the Model 6511RC Matrix Switch offers the following tool sets:  
Loopback test modes for the Matrix Switch STM-1 port  
SDH Section Trace and SDH Path Trace functions for the STM-1 link  
The following sections describe these tool sets in detail.  
Loopback test modes for the STM-1 port  
The Matrix Switch provides the following diagnostic loopback test modes for the STM-1 port:  
SDH facility loop (see section “Facility Loop [sonetFacilityLoop(1)]” on page 87)  
SDH terminal loop (see section “Terminal loop [sonetTerminalLoop(2)]” on page 88)  
H.110 loop (see section “Other Loop [sonetOtherLoop(3)]” on page 90)  
The facility and terminal loops are specified by the SDH protocol. The H.110 loop is proprietary to the Fore-  
Front Matrix Switch, and fulfills the SDH specification for a third vendor-defined loop.  
86  
Matrix Switch test tools  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
To understand how these test modes work, you must first understand the basic architecture of the Model  
6511RC’s TDM mapping functions. The TDM mapping function provides the connection between the  
STM-1 port and the H.110 bus. Within the TDM mapper (see figure 60) data passes between the SDH fram-  
ing processor and the H.110 framing processor.  
TDM Mapper  
Tx  
Rx  
Tx  
SDH  
Framer  
H.110  
Framer  
H.110 bus  
STM-1 port  
Rx  
Model 6511RC Matrix Switch  
Figure 60. Matrix Switch TDM mapping architecture  
The various loopback test modes route data through one or both of these framing processors, with the data  
path making a U-turn in one framer or the other. Subsequent paragraphs describe the details of each loopback  
test mode for the STM-1 port.  
Facility Loop [sonetFacilityLoop(1)]  
You can use the facility loop to test and troubleshoot the operation of the STM-1 link, including the Matrix  
Switch’s STM-1 port and the fiber-optic or coaxial cables connected to it.  
The facility loop (see figure 61) returns data received from the SDH facility (the STM-1 link) back to the same  
SDH facility. In other words, when the Facility Loop is activated, the Matrix Switch receives data from the  
STM-1 link and transmits the (unmodified) data back to the STM-1 link.  
The U-turn for the facility loop occurs within the SDH framer on the Matrix Switch. The data path for the  
facility loop traverses the SDH framer, but not the H.110 framer. Data enters the Matrix Switch at the STM-1  
receive port, and enters the SDH framer where it loops back toward the STM-1 link, leaving the Matrix switch  
at the STM-1 transmit port.  
Figure 61. Facility Loopback test mode  
To activate the facility loopback test mode:  
1. On the configuration menu, click the SDH hyperlink to display the SDH Overview page.  
Matrix Switch test tools  
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
2. At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration  
page (see figure 62).  
Figure 62. SDH Configuration page with sonetFacilityLoop(1) selected  
3. Scroll down to the Loopback parameter in the SDH Interface Configuration table.  
4. From the drop-down menu, select sonet(facilityLoop(1).  
5. Click the first Submit button located just below the SDH Interface Parameters table.  
To deactivate the Facility Loopback test mode, from the LoopBack parameter drop-down menu, select sonet-  
NoLoop(0) and click the Submit button.  
Terminal loop [sonetTerminalLoop(2)]  
The terminal loop (see figure 63) returns data received from the SDH terminals back to those SDH terminals  
(other ForeFront modules on the same H.110 bus). In other words, when the Terminal Loop is activated, the  
Matrix Switch receives data from other ForeFront modules via the H.110 bus and transmits the (unmodified)  
data back to those same modules (via the H.110 bus).  
The U-turn for the terminal loop occurs within the SDH framer on the Matrix Switch. The data path for the  
terminal loop traverses both the H.110 framer and the SDH framer. Data transmitted by the SDH terminals  
(other ForeFront modules) enters the Matrix Switch from the H.110 bus through the mid-plane  
Figure 63. Terminal loopback test mode  
88  
Matrix Switch test tools  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
connections. The data passes through the H.110 framer, then traverses the SDH framer where it loops back,  
passing through the H.110 framer again. The data leaves the Matrix switch through its mid-plane connections  
and returns via the H.110 bus to the sending SDH terminals (other ForeFront modules).  
The terminal loop affects only those DS0s that are mapped from the H.110 bus to the STM-1 link or from the  
STM-1 link to the H.110 bus. Likewise, the loop affects only those ForeFront modules included in one or  
more such DS0 mappings.  
The terminal loop exercises the physical and logical connections between the Matrix Switch and the other  
ForeFront modules connected to the same H.110 bus (its SDH terminals). You can use the terminal loop to  
test and troubleshoot the DS0 mappings you have defined while simultaneously testing H.110 bus connectiv-  
ity with other ForeFront modules via the chassis mid-plane.  
To activate the Terminal Loop test mode:  
1. On the configuration menu, click the SDH hyperlink to display the SDH Overview page.  
2. At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration  
page (see figure 64).  
3. Scroll down to the Loopback parameter in the SDH Interface Configuration table.  
4. From the drop-down menu, select sonetTerminalLoop(2).  
5. Click the first Submit button located just below the SDH Interface Parameters table.  
Figure 64. SDH Configuration page with sonetTerminalLoop(2) selected  
To deactivate the terminal loop test mode, from the LoopBack parameter drop-down menu, select sonet-  
NoLoop(0) and click the Submit button.  
Matrix Switch test tools  
89  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
Other Loop [sonetOtherLoop(3)]  
The other loop [sonetOtherLoop(3)] operates much like the facility loop, however the data enters the H.110  
framer where it makes a U-turn. The Other Loop test mode (See figure 65) is a factory debugging and hardware  
test tool intended for use by Patton engineering. The terminal loop and facility loop provide all the functional-  
ity a Matrix Switch operator should require. Though it is available to Matrix Switch operators, the Other Loop  
test mode offers no further advantage for testing or troubleshooting in the field.  
Figure 65. Other Loopback test mode  
SDH section trace and path trace  
The Matrix Switch supports the section trace and path trace functions specified in the SDH protocol. You can  
use these trace functions to verify connectivity across an SDH circuit or circuit segment and to validate the link  
is operating properly. When a trace is enabled, two SDH devices pass a trace message to each other across an  
SDH link or link segment. When the message arrives without errors the trace succeeds, indicating the connec-  
tion is healthy. If a device receives a trace message that does not match the expected value, a trace mismatch  
occurs, indicating an error in the connection.  
Note The trace function must be enabled and configured identically in  
both the Matrix Switch and the connected SDH network in order for  
the trace to operate.  
90  
Matrix Switch test tools  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
Sections and paths  
Between a pair of SDH multiplexers, an SDH circuit may comprise multiple cable segments connected by  
intermediate devices such as signal repeaters and add-drop multiplexers (see figure 66). A cable segment with a  
regenerator at one or both endpoints is called a section. A set of cable segments with an add-drop multiplexer at  
one or both endpoints is called a line. An SDH circuit with full-service multiplexers at both endpoints is called  
a path.  
Figure 66. Section, path, and line within an SDH circuit  
Section trace  
The section trace function verifies section connectivity between the two section-terminating nodes.Two SDH  
section-terminating devices perform the section trace over the STM-1 media segment between them. When  
section trace is enabled, the SDH frame carries a trace message in either the J0 byte or the section trace string.  
The value you define for Section Trace Message Length determines which field will carry the Section Trace Mes-  
sage, as specified below:  
1-byte section trace message lengthUse the J0 byte for trace messaging, and ignore the contents of sec-  
tion trace string. The value of J0 may be any positive integer in the range of 0 to 255.  
16-byte section trace message lengthUse the section trace string for section trace messaging, and ignore  
the contents of J0. The value of section trace string may be any alphanumeric text string up to 15 characters  
long. The 16-byte field includes CRC-7 in the 16th byte.  
64-byte section trace message lengthUse the section trace string for section trace messaging, and ignore  
the contents of J0. The value of section trace string may be any alphanumeric text string up to 64 characters  
long. The 64-byte section trace string does not include any CRC.  
To enable section trace:  
1. On the configuration menu, click the SDH hyperlink to display the SDH Overview page.  
2. At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration  
page (see figure 67).  
Matrix Switch test tools  
91  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
Figure 67. Section Trace parameters on the SDH Configuration page  
3. For Section Trace Monitor, select sectionTraceEnable(1) from the drop-down menu.  
4. For the Section Trace message string, enter the alphanumeric string your connected SDH network uses for  
the Section Trace Message String in the SDH frame.  
Note Section trace is used for 16-byte and 64-byte section trace messages.  
For 1-byte and 64-byte trace messages, the J0 byte is used and the  
value of section trace is ignored.  
5. For Section Trace Msg Len, from the drop-down menu, select the value used by the SDH network your  
Matrix Switch is connected to: either 1, 16, or 64-byte trace messages.  
6. For Section Trace J0 Byte enter the value your connected SDH network uses for the J0 byte in the  
SDH frame.  
Note J0 is used only for 1-byte section trace messages. For 16-byte and 64-  
byte trace messages, the trace message string is used and the value of  
J0 is ignored.  
7. Click the Submit button to save your work into operating memory (volatile DRAM) and activate the new  
parameter values.  
Path trace  
The path trace function verifies path connectivity between the two path-terminating nodes.The two SDH  
path-terminating devices perform the trace over the STM-1 media segment between them. When Path Trace is  
enabled, the SDH frame carries the Path Trace message in either the J1 byte or the path trace string. The value  
you define for Path Trace Message Length determines which field will carry the Path Trace message, as specified  
below:  
1-byte Trace Message Lengthuse the J1 byte for trace messaging, and ignore the contents of path trace  
string. The value of J0 may be any positive integer in the range of 0 to 255.  
16-byte Trace Message Length  
use the path trace string for path trace messaging, and ignore the con-  
tents of J1. The value of path trace string may be any alphanumeric text string up to 15 characters long. The  
16-byte field includes CRC-7 in the 16th byte.  
92  
Matrix Switch test tools  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
64-byte Trace Message Length  
use the section trace string for section trace messaging, and ignore the  
contents of J1. The value of section trace string may be any alphanumeric text string up to 64 characters long.  
The 64-byte field does not include any CRC.  
Number of paths per frame  
The STM-1 frame can support one path or three paths, depending on how the STM-1 signal is mapped.  
AU-4 mappingUsing AU-4 mapping the STM-1 frame supports a single path. When you select AU-4  
mapping for the value of the SDH Mapping parameter, the Matrix Switch displays only the Path-1 Trace  
parameters.  
AU-3 mappingUsing AU-3 mapping the STM-1 frame supports three paths. Each of the three AU-3s in  
the STM-1 frame represents a separate path. When you select AU-3 mapping for the value of the SDH Map-  
ping parameter, the Matrix Switch displays the path trace parameters for each of the three paths. Path-1,  
Path-2, and Path-3 (one path trace for each AU-3 in the STM-1 frame).  
To enable path trace:  
1. On the configuration menu, click the SDH hyperlink to display the SDH Overview page.  
2. At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration  
page (see figure 68).  
Figure 68. Path Trace parameters on the SDH Configuration page  
3. In the SDH Trace Parameters table, for Path-1 Trace Monitor, select pathTraceEnable(1) from the drop-  
down menu.  
4. For Path-1 Trace message string, enter the alphanumeric string your connected SDH network uses for the  
path-1 trace message in the text box.  
Matrix Switch test tools  
93  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
Note Path-1 trace message is used for 16-byte and 64-byte path-1 trace  
messages. For 1-byte and 64-byte trace messages, the J1 byte is used  
and the value of path-1trace message is ignored.  
5. For Path-1 Trace Msg Len, select the value corresponding to the trace message length your connected SDH  
network uses.  
6. For Path-1 Trace J1 Byte, enter the value your connected SDH network uses for the J1 byte in the  
SDH frame.  
Note J1 is used only for 1-byte path trace messages. For 16-byte and 64-  
byte trace messages, the trace message string is used and the value of  
J1 is ignored.  
7. For Path-1 Signal Label, enter the value your connected SDH network uses for the path-1 signal label in  
the SDH frame.  
8. If you have selected AU-3 mapping, repeat steps 3 through 7 to define values for the Path-2 and Path-3  
trace parameters.  
9. Click the Submit button to save your work into operating memory (volatile DRAM) and activate the new  
parameter values.  
Periodic maintenance  
Consult the rack chassis user manual for information on preventative maintenance (such as cleaning the chassis  
air cooling vents to remove accumulated dust).  
Calibration  
The Model 6511RC requires no calibration.  
Maintenance  
This section describes replacing the Model 6511RC.  
Replacing the Model 6511RC  
If you isolate a problem to the a Model 6511RC component, the entire Model 6511RC must be replaced  
as described in the follow section.  
Exporting the current Model 6511RC configuration  
The 6511RC Matrix Switch provides Import/Export functions. These functions enable you to back up (export)  
and restore (import) your Matrix Switch’s configuration parameters against possible failure. Should your  
Matrix Switch ever need replacing, a previously saved copy of your (exported) configuration file can quickly be  
loaded (imported) into a replacement Matrix Switch.  
Note Import/Export functions require superuser access privileges.  
94  
Periodic maintenance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
Note The parameters that will be exported are the power-up settings as they  
are stored in flash memory and may not be the current operating  
parameters. To ensure that you export the most current parameters,  
go to HOME, then under Operator Actions, click on the Record  
Current Configuration button.  
1. If you already have an exported backup copy of your current configuration, go to “Removing the defective  
Model 6511RC” on page 97. Otherwise, go to step 2.  
2. On the Configuration Menu pane, click the Import/Export hyperlink to display the Import/Export page  
(figure 69).  
Figure 69. Import/Export page  
Maintenance  
95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
3. To make a back-up copy of the configuration file currently stored in your Matrix Switch’s flash memory:  
– On the Import/Export page (figure 69 on page 95) click the Export Flash... hyperlink. The Matrix  
Switch will get the configuration file currently stored in your Matrix Switch’s flash memory and display  
it in your browser (figure 70)  
Figure 70. Example Matrix Switch flash memory configuration file displayed in a browser  
96  
Maintenance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
– To save the displayed data as a text file, use your browser’s Save function (see figure 71). Using Netscape  
or Internet Explorer, for example.  
• Click the File menu.  
• Click Save As. A dialog box will appear. Use the dialog to save the data displayed on your browser  
(your Matrix Switch configuration parameters) to a text file.  
• Select the folder in which you want to store the file,  
• Type a file name.  
• Click Save.  
Figure 71. Saving the access server flash memory configuration data as a text file  
Removing the defective Model 6511RC  
1. Remove the replacement Model 6511RC from its shipping container and place it near the chassis in which  
the malfunctioning Model 6511RC is located.  
Note The Model 6511RC Matrix Switch modules are hot-swap-able, so it is  
not necessary to deactivate the rack chassis before replacing a module.  
2. Disconnect and label the following cables from the malfunctioning Model 6511RC:  
– The STM-1 WAN cable  
– The RS-232 CONFIG cable (if installed)  
– The 10/100 Ethernet cable (if installed)  
– The two 10/100/1000 Ethernet cables (if installed)  
Maintenance  
97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
Note Be sure to wear an anti-static strap to prevent electrostatic damage to  
the module.  
3. Simultaneously press both red buttons on the front-panel handles of the 6511RC to unlock the handles  
and prepare the module for removal.  
4. Simultaneously press both black handles outward and away from the center of the module to unseat the  
6511RC from the mid-plane connectors.  
5. Pull the handles gently and firmly to completely remove the Model 6511RC from the rack chassis. Place  
the module on an anti-static surface.  
6. Repeat the above procedure to remove the rear module from the rack chassis. Place the rear module on an  
anti-static surface.  
7. Place the removed modules in the container the replacement Model 6511RC came in so you can return  
the defective Model 6511RC for repair.  
Installing the replacement Model 6511RC  
1. Insert the replacement Model 6511RC into the rack chassis.  
2. Insert the rear blade into the desired slot in the rack chassis. Make sure the blade is seated properly in the  
slot guides.  
3. Gently press the blade into the chassis until the alignment/ESD pin engages the chassis. When the blade is  
fully seated, the red buttons in the handles click up automatically, thus locking the handle and activating  
the switch (closed position). The click of the button gives a visual and audible confirmation that the board  
is fully seated.  
4. Connect the following cables to the Model 6511RC:  
– The STM-1 WAN cable  
– The RS-232 CONFIG cable  
– The 10/100 Ethernet cable  
– The two 10/100/1000 Ethernet cables (if used)  
5. Verify that the green POWER LED is lit.  
Importing a saved configuration  
Before importing a saved configuration, you must define the Model 6511RC’s IP address and netmask. These  
parameters are defined via the Model 6511RC RS-232 CONFIG port on the Model 6511RC.  
1. Refer to chapter 3, “Configuring the Matrix Switch for operation” on page 41 and follow the procedures  
2. To import a saved configuration, connect your Web browser to the Administration Pages, then click on  
Import/Export under the Configuration Menu to display the Import/Export page (figure 69 on page 95).  
3. To import a configuration file into the Model 6511RC, type the complete path and filename for the con-  
figuration file you wish to load or click on the Browse… button to select the desired file, then click the  
Submit Query button.  
98  
Maintenance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Model 6511RC User Manual  
5 • Troubleshooting and maintenance  
Upon successfully importing the file, the Model 6511RC will display Configuration Load Complete, indi-  
cating that the new operating parameters have been loaded into flash memory.  
4. On the Configuration Menu, click the HOME hyperlink, then click the Hard Reset button under Opera-  
tor Actions.  
Note Do not select Record Current Configuration after importing con-  
figuration parameters.  
Completing the installation  
This section verifies that the Model 6511RC is fully operational.  
1. Verify that the green POWER LED is lit. If the POWER LED is flashing green, refer to Chapter 5, “Trou-  
bleshooting and maintenance”.  
2. Verify that the WAN LED illuminates, indicating that the Model 6511RC is synchronizing with the  
T1/E1 signal.  
3. Verify that after 5 seconds, the WAN LED begins flashing, indicating that the Model 6511RC is satisfied  
with the quality of the T1/E1 signal.  
4. Verify that after 10 seconds, the WAN LED extinguishes, indicating that the Model 6511RC is satisfied  
with the network signal and that the link is ready for use.  
5. Verify that the green Ethernet LED is either flashing (indicating link status is nominal for the front Ether-  
net port) or on solid (indicating that link status is nominal for at least one of the Ethernet backplane con-  
nections).  
The Model 6511RC is operational.  
Maintenance  
99  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 • Troubleshooting and maintenance  
Model 6511RC User Manual  
100  
Maintenance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 Contacting Patton for assistance  
Chapter contents  
Introduction........................................................................................................................................................102  
Contact information............................................................................................................................................102  
Warranty Service and Returned Merchandise Authorizations (RMAs).................................................................102  
Warranty coverage ........................................................................................................................................102  
Out-of-warranty service ...........................................................................................................................102  
Returns for credit ....................................................................................................................................102  
Return for credit policy ...........................................................................................................................103  
RMA numbers ..............................................................................................................................................103  
Shipping instructions ..............................................................................................................................103  
101  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6 • Contacting Patton for assistance  
Model 6511RC User Manual  
Introduction  
This chapter contains the following information:  
“Contact information”—describes how to contact PATTON technical support for assistance.  
RAS warranty and obtaining a return merchandise authorization (RMA).  
Contact information  
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other  
products we recommend you begin your search for answers by using our technical knowledge base. Here, we  
have gathered together many of the more commonly asked questions and compiled them into a searchable  
database to help you quickly solve your problems.  
Online support—available at www.patton.com.  
E-mail support—e-mail sent to [email protected] will be answered within 1 business day  
Telephone support—standard telephone support is available Monday through Friday, from 8:00 A.M. to  
5:00 P.M. EST (8:00 to 17:00 UTC-5), Monday through Friday by calling +1 (301) 975-1007  
Warranty Service and Returned Merchandise Authorizations (RMAs)  
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship-  
ment. All of our products are backed by a comprehensive warranty program.  
Note If you purchased your equipment from a Patton Electronics reseller,  
ask your reseller how you should proceed with warranty service. It is  
often more convenient for you to work with your local reseller to  
obtain a replacement. Patton services our products no matter how  
you acquired them.  
Warranty coverage  
Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod-  
uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work-  
manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or  
unauthorized modification.  
Out-of-warranty service  
Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no  
longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or elephants may  
require replacement.  
Returns for credit  
Customer satisfaction is important to us, therefore any product may be returned with authorization within 30  
days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or  
you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is  
not responsible for equipment returned without a Return Authorization.  
102  
Introduction  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Model 6511RC User Manual  
6 • Contacting Patton for assistance  
Return for credit policy  
Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.  
30 to 120 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase  
price).  
Over 120 days: Products will be accepted for repairs only.  
RMA numbers  
RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:  
Completing a request on the RMA Request page in the Support section at www.patton.com  
By calling +1 (301) 975-1000 and speaking to a Technical Support Engineer  
By sending an e-mail to [email protected]  
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use  
the original packing material that the device came in or pack the unit securely to avoid damage during shipping.  
Shipping instructions  
The RMA number should be clearly visible on the address label. Our shipping address is as follows:  
Patton Electronics Company  
RMA#: xxxx  
7622 Rickenbacker Dr.  
Gaithersburg, MD 20879-4773 USA  
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return  
shipping costs.  
Warranty Service and Returned Merchandise Authorizations (RMAs)  
103  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6 • Contacting Patton for assistance  
Model 6511RC User Manual  
104  
Warranty Service and Returned Merchandise Authorizations (RMAs)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Philips Bottle Warmer SCF129 11 User Manual
Philips Satellite TV System SDV2927 User Manual
Philips TV Antenna SDV2510 27 User Manual
Philips Universal Remote SBC RU 538 00 User Manual
Philips Work Light PL Series User Manual
Pioneer Stereo System VSX 915 K User Manual
Polaris Offroad Vehicle 120 Pro X User Manual
Poulan Snow Blower 429956 User Manual
Powermate Portable Generator PM4025 User Manual
Pride Mobility Mobility Aid 1122 3SP 1122 4MP User Manual