LOW NOx TURBOPOWER® • PACKAGED WATER HEATER
NICKELSHIELD® NICKEL-PLATED STORAGE TANK
TANK SERIES 750 GALLONS VERTICAL
Min. Inlet
Blower
Motor
Shipping
Weight
lbs
Dimensions (inches)
Recovery gph c
MODEL
NUMBER
INPUT
Btu/h
Flow Gas
Pressure
" W.C. e
SCAQMD Energy
Model No.
40° - 120°F 40° - 140°F
A
B
C
J d
HP
1/3
Amps
500 N 750A-TPL
500
400
399,000
4.5
4TPL
399 MBtu/h 28
5
3/4
16
8
2660
c Recoveries based on 83% thermal efficiency. ASHRAE 90.1 compliant for efficiency and standby loss.
d “J” dimension is for the burner housing only – gas train may exceed this dimension.
e Standard gas train.
* The information presented is for natural gas 0.6 S.G.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see form #PV6540.
STANDARD GAS PRESSURE REQUIREMENTS:
STANDARD ELECTRICAL REQUIREMENTS:
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.
MAXIMUM STATIC INLET GAS PRESSURE IS 14" W.C.
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS.
MOTOR VOLTAGE: 1/3 HP ARE 120V, 1Ø, 60 HZ.
FOR GAS PRESSURES OUTSIDE OF THIS RANGE,
CONTACT YOUR PVI REPRESENTATIVE.
208V, 230V AND 460V MOTORS ARE AVAILABLE BUT WILL
REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN
OPTIONAL CONTROL CIRCUIT TRANSFORMER.
VENTING REQUIREMENTS:
-.02" TO -.06" W.C. (NEGATIVE PRESSURE).
TYPE B VENTING.
ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON
THE VENT CONNECTION DIAMETER EXCLUSIVELY. CHECK
NATIONAL FUEL GAS CODE UNDER "FAN ASSISTED."
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND
SPECIFICATION WITHOUT NOTICE.
Product is patented in the U.S., Canada, and Mexico.
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
PV 6549 11/07