Patton electronic Projection Television Im1 k User Manual

USER  
MANUAL  
MODELS IM1/K and IM2RC/K  
G.703/G.704 QuikConnect™  
and Rear Card Modules  
Part# 07MIM1/K-C  
Doc# 090131UC  
Revised 08/01/00  
SALES OFFICE  
(301) 975-1000  
TECHNICAL SUPPORT  
(301) 975-1007  
C
E
R
T
I
F
I
E
D
An ISO-9001  
Certified  
Company  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.4 SERVICE INFORMATION  
1.2 RADIO AND TV INTERFERENCE  
All warranty and non-warranty repairs must be returned freight  
prepaid and insured to Patton Electronics. All returns must have a  
Return Materials Authorization number on the outside of the shipping  
container. This number may be obtained from Patton Electronics  
Technical Support at:  
The Models IM1/K and IM2RC/K (K Module) generate and use  
radio frequency energy, and if not installed and used properly—that is,  
in strict accordance with the manufacturer's instructions—may cause  
interference to radio and television reception. If the K Module does  
cause interference to radio or television reception, which can be deter-  
mined by disconnecting the cables, the user is encouraged to try to  
correct the interference by one or more of the following measures:  
moving the computing equipment away from the receiver, re-orienting  
the receiving antenna, and/or plugging the receiving equipment into a  
different AC outlet (such that the computing equipment and receiver  
are on different branches).  
tel: (301) 975-1007  
NOTE: Packages received without an RMA number will not be  
accepted.  
1.3 CE AND TELECOMMUNICATION APPROVALS  
Patton Electronics' technical staff is also available to answer any  
questions that might arise concerning the installation or use of your  
Patton K Module. Technical Support hours: 8AM to 5PM EST,  
Monday through Friday.  
The CE symbol on your Patton Electronics equipment indicates  
that it is in compliance with the Electromagnetic Compatibility (EMC)  
directive and the Low Voltage Directive (LVD) of the Union European  
(EU). A Certificate of Compliance is available by contacting Technical  
Support.  
The K Module is in compliance with the Telecommunication techni-  
cal requirements CTR-12; 2.048 Mbps digital unstructured leased line  
(D2048U) attachment requirements for terminal equipment  
interface.  
The K Module also meets the Telecommunication technical  
requirements CTR-13; 2.048 Mbps digital structured leased lines  
(D2048S) attachment requirements for terminal equipment interface.  
4
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.0 GENERAL INFORMATION  
3.0 TYPICAL APPLICATION  
Thank you for your purchase of this Patton Electronics product.  
This product has been thoroughly inspected and tested and is warrant-  
ed for One Year parts and labor. If any questions arise during installa-  
tion or use of the unit, contact Patton Electronics Technical Support at  
(301) 975-1007.  
The K Module can be deployed in one of two applications:  
G.703/G.704 Network Termination (nx64kpbs to 2.048Mbps), and  
G.703/G.704 Network Extension (nx64 kbps to 2.048Mbps). Both appli-  
cations are discussed below.  
2.1 FEATURES  
3.1 NETWORK TERMINATION APPLICATION  
• Quick Connect and Rear Card Modules for use with Patton  
mDSL modems  
• nx64 G.703/G.704 Network Termination or Network  
Extension Applications  
Network Termination mode is used to connect a local site  
modem employing a K Module to a remote site modem employing  
a V.35, X.21, RS-530 Ethernet QuikConnect Module (refer to  
Figure 1, below). Transmitter clocking is derived from the  
G.703/G.704 network and carried through the system to all system  
devices.  
• Supports rates up to 2.048 (E1) Mbps  
• 2.048Mbps G.703 Clear Channel (Unframed) or nx64 G.704  
(Framed) Operation  
• Selectable AMI or HDB3 Line Coding  
• Configuration via DIP Switches and Jumpers  
• Coax (BNC) connection for 75 ohm  
• RJ-48C connection via twisted pair for 120 ohm  
• Made in USA  
K Module and  
mDSL Modem  
mDSL Modem with  
Serial Interface  
nx64kbps  
G.703/G.704  
Network  
Receive  
Recover  
Clocking  
V.35  
Router  
External  
Clocking  
Cable Span  
Clock/  
Data  
Clock/  
Data  
2.2 GENERAL PRODUCT DESCRIPTION  
Data  
Clock/  
Data  
The Patton Model IM1/K G.703/G.704 QuickConnect Module and  
IM2RC/K Rear Card Module provide E1/Fractional E1 termination and  
extension capabilities to the Patton NetLink mDSL modems  
(1095/1095RC). When used with a Patton mDSL modem, a  
G.703/G.704 line can be terminated or extended to a remote site up to  
10km away.  
1095  
(1095RC)  
V.35 Module  
K Module  
1095  
(1095RC)  
Figure 1. Clocking Settings in a Network Termination Application  
There are two separate applications that can be employed  
when using the K Modules; Network Termination or Network Extension.  
In a Network Termination application, the G.703/G.704 line is terminat-  
ed at the K Module and the clock and data is sent to the far end of the  
link. At the remote site, a Patton mDSL modem with a serial/Ethernet  
interface will be running the nx64 DTE rate. This application allows the  
remote user without a G.703/G.704 interface to extend the serial inter-  
face that is available to the G.703/G.704 access point without the need  
for a separate G.703/G.704 to serial converter. In the G.703/G.704  
Network Extension application, two K Modules are employed, one at  
each end of the link. This application allows the user to extend the  
G.703/G.704 network over 10km away.  
The K Module supports switch selectable AMI or HDB3 encoding,  
all nx64 kbps bit rates and both dual coaxial (75 ohm) and RJ-48C  
(120 ohm) G.703/G.704 terminations. The K Module is made in the  
USA. The K Module is CE marked and complies to applicable CTR  
standards.  
6
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2 NETWORK EXTENSION APPLICATION  
4.0 CONFIGURATION  
Network Extension mode is used to extend nx64 -2.048Mbps  
G.703/G.704 service across a DSL link, providing an nx64  
G.703/G.704 link at the remote site. Transmitter clocking is  
derived from the G.703/G.704 network, and transmitted over the  
baseband modem link (refer to Figure 2, below).  
The K Module features configuration capability via hardware  
switches and jumpers. Sections 4.1 and 4.2 describe all switch and  
jumper configurations for the Patton K Module. Section 4.3 describes  
the configuration required for your mDSL modem.  
4.1 DIP Switch Configuration  
K Module and  
mDSL Modem  
K Module and  
mDSL Modem  
The K Module has eight internal DIP switches (S1-1 through S1-8).  
The DIP switches can be configured as either “On” or “Off.” See  
Appendix D for location and orientation of the DIP switches.  
nx64kbps  
G.703/G.704  
CPE  
External  
Clocking  
set to Force CP  
nx64kbps  
G.703/G.704  
Network  
External  
Clocking  
Cable Span  
Clock/  
Data  
Clock/  
Data  
Clock/  
Data  
Switch S1-1: Line Coding  
Clock/  
Data  
Use Switch S1-1 to control the Network Line Coding options. Set  
these options to be the same as the Line Coding that has been provid-  
ed by your Service Provider.  
1095  
(1095RC)  
K Module  
K Module  
1095  
(1095RC)  
S1-1  
Off  
On  
Line Framing & Coding  
HDB3  
AMI  
Figure 2. Clock Settings in a Network Extension Application  
Line Coding Options:  
High Density Bipolar 3 (HDB3): In HDB3 coding, the transmitter  
deliberately inserts a bipolar violation when excessive zeros in the  
data stream are detected. The receiver recognizes these special  
violations and decodes them as zeros. This method enables the  
network to meet minimum pulse density requirements. Use HDB3  
unless AMI is required in your application .  
Alternate Mark Inversion (AMI): AMI coding does not inherently  
account for ones density. To meet this requirement, you should  
ensure that the data inherently meets pulse density requirements.  
Switch S1-2 : CRC-4 Multiframe  
CRC-4 Multiframe uses Time Slot zero to carry CRC-4 information.  
When CRC-4 is enabled (ON), the unit synchronizes to the CRC-4  
multi-frame protocol.  
S1-2  
Off  
On  
Option  
Disabled  
Enabled  
NOTE: When the data rate is set to 2048 Kbps, K Module trans-  
mits user data on all 32 timeslots, ignoring framing information. In  
this case, Switch S1-2 will be ignored.  
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Switch S1-3 : Clear Channel Mode  
Clock Mode  
The mDSL modem must be set for the External Clock mode when  
When S1-3 is at Off position, the K Module is running in G.703  
clear channel mode. When S1-3 is at On position, the K Module is run-  
ning in G.704 framed mode. When the K Module is set to framed  
mode, channel 0 will be used to pass G.704 framing information which  
results in a maximum bandwidth of 1984kbps for user data.  
a K Module is installed. The modem will always receive the clocking  
from the K Module. If you are configuring a Network Extension applica-  
tion, set both modems for External Clock mode. If you are configuring  
a Network Termination application, please set the modem with the K  
Module for External Clock and the unit with the serial/Ethernet inter-  
face for Receive Recovered clock mode. In order to determine the  
switch settings specific to your unit, refer to the mDSL manual that was  
shipped with your unit.  
S1-3  
Off  
On  
Option  
Clear Channel Mode (G.703)  
Framed Mode (G.704)  
Switch S1-4 Through S1-8 : Reserved  
CO-CP  
Reserved for future use and should be set to OFF.  
The CO/CP selection tells the units which modem will begin the  
handshaking for the link. In all applications one unit must be set for CO  
and one unit must be set for CP, they work in pairs. A mDSL modem  
set for either Internal or External clock mode will automatically default  
to the CO mode. A mDSL modem set for Receive Recovered clock  
mode will automatically default to the CP mode. If you are configuring  
a Network Extension application, you must force one of the units to  
CP mode by setting S2-1 on the mDSL modem to the ON position.  
Note that the mDSL manual refers to this switch as "Reserved". If you  
are running in the Network Termination mode, no extra configuration is  
required.  
4.2 Jumper Configuration  
The Patton K Module has four jumpers (two position headers):  
JP4, JP5, JP6, and JP7. These jumpers are used to select input and  
output impedance matching between the module and external line. See  
Appendix E for jumper locations.  
The following is a description of the jumper settings with respect  
to the front panel connectors.  
1. For a 75 ohm connection (coax) install JP4 - JP7 (default).  
Interface Type  
2. For a 120 ohm connection (RJ-48C) remove JP4 - JP7.  
The mDSL modem requires that the interface type is specified.  
Any unit that has a K Module installed must be set to G.703/G.704  
Interface. This is done by setting S2-5 on the mDSL modem to ON.  
Note that the mDSL manual refers to this switch as "Reserved".  
4.3 Configuring Your Model 1095 mDSL Modem  
DTE Rate for the mDSL Modems  
This section describes how to configure your mDSL modem for  
use with an IM1/K (Model 1095) or an IM2RC/K (Model 1095RC).  
To select the number of G.703/G.704 channels to be carried  
across the link, multiply the number of required channels by 64Kbps  
and then set the DTE rate of the mDSL modem to that number. The  
mDSL modem will then carry that number of channels from the  
G.703/G.704 line, starting with channel 1 (Note channel 0 is used for  
G.704 framing information) across the DSL link. For example, if you  
want to carry 4 channels across the DSL link, set the mDSL DTE Rate  
to 256Kbps (4 x 64Kbps = 256Kbps). The mDSL modem and the K  
Module will then carry channels 1 - 4 across the DSL link.  
The K Module requires the 1095/1095RC to have software ver-  
sion 2.3.2 or later, which began shipping on 04/01/00.  
If you are unsure of the software revision of your unit, please con-  
tact Patton Electronics Technical Support.  
If you are running in clear channel mode, set switch S1-3 on the K  
Module to "clear channel" and set the DTE Rate of your mDSL modem  
to 2048Kbps.  
9
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the New QuikConnect™ Module  
5.0 INSTALLATION  
1) Make sure the power switch is off. Leave the power cord  
plugged into a grounded outlet to keep the unit grounded.  
2) Hold the module with the faceplate toward you and align the  
module with the guide slots in the rear panel of the NetLink  
Chassis.  
3) While keeping the module’s faceplate parallel with the NetLink  
chassis rear panel, slide the module straight in – so that the  
card edge contacts line up with the socket inside the chassis.  
4) With the card edge contacts aligned with the socket, firmly seat  
the module by using your thumbs to apply pressure directly to  
the right and left edges of the module faceplate. Applying mod-  
erate and even pressure should be sufficient to seat the mod-  
ule. You should hear it “click” into place.  
This section describes how to install the IM1/K and IM2RC/K mod-  
ules into your mDSL modems. Please refer to the section in this manu-  
al that describes your unit.  
5.1 Installing the IM1/K  
The QuickConnect™ interface on the NetLink Modems are inter-  
changeable Modules. Each QuikConnect™ Module has a 50-pin card  
edge connector on one side and a Network interface on the other.  
Figure 3 below shows how a QuikConnect™ Module plugs into the  
back of the Model 1095.  
5) To secure the module in place, push the thumbscrews into the  
chassis and turn the screws clockwise to tighten.  
5.2 Installing the IM2RC/K and Front Fuction Card  
The Model IM2RC/K is a rear-mountable G.703/G.704 interface  
card that works with the Patton Model 1095RC function card. The two  
cards meet inside the rack chassis and plug into each other by way of  
mating 50 pin card edge connectors. Use the following steps as a  
guideline for installing each Model IM2RC/K and its function card mate  
into the rack chassis:  
1. Slide the rear card into the back of the chassis along the  
metal rails provided.  
Figure 3. Installation of Model 1095 Plug-in K Module  
2. Secure the rear card using the metal screws provided.  
3. Slide the front card into the front of the chassis. It should  
meet the rear card when it’s almost all the way into the chas-  
sis.  
4. Push the front card gently into the card-edge receptacle of the  
rear card. It should “click” into place.  
5.1.1 Changing QuikConnect™ Modules  
When you purchase a NetLink™ mDSL modem, it should be  
shipped to you with the appropriate QuikConnect™ Module already  
installed. If you need to install a different QuikConnect™ Module, fol-  
low these steps:  
5. Secure the front card using the thumb screws.  
Removing the Existing QuikConnect™ Module  
The IM2RC/K is shipped with an IM1RC/K flip card. Ensure that  
the flip card is secured in the flip card socket on the 1095RC with the  
1) Turn the power switch off. Leave the power cord plugged into  
a grounded outlet to keep the unit grounded.  
2) Loosen the two thumbscrews on the module by turning them  
counterclockwise.  
arrow (  
) pointing toward the front panel. Please see the Model  
1095RC User Manual (section 3.0 Configuration), for more informa-  
tion on installing the flip card.  
3) Grasp the two thumbscrews and gently pull the module from  
the unit. Apply equal force to the thumbscrews to keep the  
module straight during the removal process  
12  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.3 MAKING INTERFACE CONNECTIONS  
RJ-48C Cable (8-Wire)  
The Patton K Module may be connected to G.703/G.704 ports  
using a single 120 ohm RJ-48C or a dual 75 ohm coax (BNC). The  
Patton K Module rear panels and the location of these connectors are  
show below in Figure 4.  
K Module  
SIGNAL  
G.703/G.704  
NETWORK SIGNAL  
PIN#  
RX+  
RX-  
1-----------------------TX+  
2-----------------------TX-  
Network  
TX+  
TX-  
5-----------------------RX+  
4-----------------------RX  
Shield  
Shield  
3-----------------------Shield  
6-----------------------Shield  
RX  
TX  
5.3.2 Connect Dual Coaxial Cable (75 ohm) to G.703/G.704 Network  
The Patton K Module is also equipped with dual female BNCs (TX  
and RX) for connection to a 75 ohm dual coax G.703/G.704 network  
interface. If your G.703/G.704 network terminates via dual coaxial  
cable, use the diagram below to make the proper connections. The  
connector pinout and signals are shown in Figure 6, below.  
TX  
RX  
Network  
Figure 4: K Module Rear Panels, Showing Location of Connectors  
RX  
TX  
TX  
RX  
5.3.1 Connect Twisted Pair (120 ohm) to G.703/G.704 Network  
(Data FROM  
G.703/G.704  
Network)  
(Data TO  
G.703/G.704  
Network)  
The Patton K Module is equipped with a single RJ-48C jack for  
connections to a 120 ohm twisted pair G.703/G.704 network interface.  
If your G.703/G.704 network terminates via RJ-48C, use the diagram  
below and the table on the following page to make the proper connec-  
tions. The connector pinout and signals are shown in Figure 5, below.  
Use the following connection diagram to connect the 120 ohm  
G.703/G.704 network channel.  
TX  
RX  
(No Connection) 8  
(No Connection) 7  
(No Connection) 6  
(TX+) 5  
(TX-) 4  
(No Connection) 3  
(RX-) 2  
8
7
6
5
4
3
2
1
Figure 6: 75 ohm Dual Coaxial G.703 Interface  
NOTE: The outer conductor of the coax cables are isolated  
from system earth ground.  
(RX+) 1  
Figure 5: 120 ohm RJ-48C G.703/G.704 Interface  
13  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.0 OPERATION  
APPENDIX A  
Once the Patton K Module is installed and configured, it should  
operate transparently. Please refer to the base unit (i.e. Model 1095)  
user manual for instructions on how to read the front panel LEDs, per-  
form diagnostics, monitor system status, and connect to the DSL line  
port.  
PATTON ELECTRONICS MODEL K MODULE  
SPECIFICATIONS  
G.703/G.704 Interfaces: Female Dual Coaxial 75 ohm  
Female RJ-48C 120 ohm  
Line Framing:  
Line Coding:  
Clock Options:  
G.703 (unframed) or G.704 (framed)  
Switch Selectable AMI or HDB3  
Network Termination and Network  
Extension  
DTE Rates:  
(selected on the base unit)  
Nx64 rates (kbps): 64, 128, 192, 256, 320,  
384, 448, 512, 576, 640, 704, 768, 832,  
896, 960, 1024, 1088, 1216, 1280, 1344,  
1408, 1472, 1536, 1600, 1664, 1728, 1792,  
1856, 1920, 1984, 2048  
Distance:  
Maximum 1.6 km on 24 AWG Cable  
Isolation:  
1500 Vrms  
Power Supply:  
Power Supplied via NetLink Standalone Unit  
or NetLink front card  
Compliance:  
Dimensions:  
CE Mark per EMC Directive 89/336/EEC  
and Low Voltage Directive 73/23/EEC,  
RTTE 99/5/EC Directive  
6.17 x 1.42 x 7.42 cm (2.43 x .56 x 2.92  
inches)  
Humidity:  
Up to 95% non-condensing  
32 to 140º F (0 to 60º C)  
Temperature:  
16  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX C  
APPENDIX B  
K MODULE  
PATTON K MODULE  
FACTORY REPLACEMENT PARTS  
AND ACCESSORIES  
CABLE RECOMMENDATIONS  
Patton Electronics Model #  
Description  
All Patton Electronics Company Baseband Modems, CSU/DSUs  
and Short Range Modem are tested to the distances published in our  
Catalogs and Specification Sheets on twisted-pair cable with the fol-  
lowing characteristics:  
07MIM1/K Module...........K Module User Manual  
IM1/K Module..................K Module for use with Model 1095  
IM2RC/K Module.............K Module for use with Model 1095RC  
IM1RC/K Module.............K Module flip card  
Wire Gauge  
Capacitance  
Resistance  
19 AWG  
22 AWG  
24 AWG  
26 AWG  
83nF/mi or 15.72 pF/ft.  
83nF/mi or 15.72 pF/ft.  
83nF/mi or 15.72 pF/ft.  
83nF/mi or 15.72 pF/ft.  
.0163 ohms/ft.  
.0326 ohms/ft.  
.05165 ohms/ft.  
.08235 ohms/ft.  
We fully expect that the Baseband Modems, CSU/DSUs and Short  
Range Modems will operate on lines with specifications different from  
those tested, but to reduce the potential difficulties in the field, one  
should ensure that the cable being used has similar or better charac-  
teristics (lower capacitance or lower resistance).  
Wire with capacitance of 20pF/ft. or less is suitable for all  
Baseband Modems, CSU/DSUs and Short Range Modems. However,  
distances may vary from those published in our catalog. Resistance  
will also affect distance but not functionality. Wire should be 26 AWG  
or larger (smaller AWG#).  
Patton products are designed to withstand normal environmental  
noise and conditions; however, other environmental factors too numer-  
ous to discuss in this format may affect proper operation.  
Selection of the proper Baseband Modem, CSU/DSU or SRM for  
an application is critical to maintaining Customer Satisfaction and must  
be taken seriously. Certain models are better suited for particular  
applications and environments than others.  
18  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX E  
APPENDIX D  
PATTON K MODULE  
DIP SWITCHES  
PATTON K MODULE JUMPER SETTINGS  
Figure A (below) shows the location of the DIP switches on top of  
the printed circuit board. Following Figure A, Figure B shows the ori-  
entation of the DIP switches on the printed circuit board.  
Figure C (below) shows the top view of the IM1/K printed circuit  
board (PCB) and the location of the jumpers.  
Interface Panel  
Interface Panel  
JP5  
JP4  
JP5  
JP4  
DIP Switches  
JP7  
JP6  
JP7  
JP3  
JP6  
JP1  
JP3  
JP1  
ON  
OFF  
ON  
OFF  
Edge Connectors  
Front Panel  
Figure A. IM1/K top view, showing location of DIP switches  
Edge Connectors  
Figure C. K Module, top view, showing location of jumpers  
DIP Switches  
Figure D (below) shows the top view of the IM2RC/K printed circuit  
board (PCB) and the location of the jumpers.  
OFF  
ON  
1
2
3
4
5
6
7
8
Rear  
O N  
DIP Switches  
OFF  
ON  
1
2
3
4
5
6
7
8
Front  
Panel  
Rear  
O N  
JP5  
JP4  
JP6  
JP7  
JP9  
Figure B. IM2RC/K, top view, showing location of DIP switches  
JP3  
Figure D. IM2RC/K, top view, showing location of jumpers  
19  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Dishwasher Incognito User Manual
MTD Snow Blower 769 01275D User Manual
MTD Tiller 216 403 000 User Manual
National Instruments Computer Accessories 370757C 01 User Manual
Nikon Network Router MFX 1930 User Manual
Niles Audio Stereo System C5 VA2 User Manual
Nilfisk ALTO Vacuum Cleaner 30 BATT PC XC User Manual
Onkyo Stereo Receiver TX 8511 User Manual
Panasonic Digital Camera AK HC930P User Manual
ParaBody Home Gym 425101 User Manual