Patton electronic Network Router 3040 V35 User Manual

Doc #: 139001UA  
Part #: 07M3040-A  
B
DIGITAL BRIDGE  
3040/V35  
(CTS MD-V.35/TCB)  
INSTALLATION AND OPERATIONS MANUAL  
June 10, 1997  
AnISO-9001  
CertifiedCompany  
Copyright© 2000 Patton Electronics Co., All Rights Reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
EMISSION REQUIREMENTS  
RADIO AND TV INTERFERENCE  
The Patton devices generate and use radio frequency energy, and if not installed and used  
properly—that is, in strict accordance with the manufacturer’s instructions—may cause  
interference to radio and television reception. The Patton devices have been tested and found  
to comply with the limits for Class A computing devices in accordance with the specifications  
in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection  
from such interference in a commercial installation. However, there is no guarantee that  
interference will not occur in a particular installation. If the Patton devices do cause  
interference to radio or television reception, which can be determined by disconnecting the  
cables, the user is encouraged to try to correct the interference by one or more of the following  
measures: moving the computing equipment away from the receiver, re-orienting the receiving  
antenna, and/or plugging the receiving equipment into a different AC outlet (such that the  
computing equipment and receiver are on different branches).  
CANADIAN EMISSIONS  
This digital apparatus does not exceed the Class A limits for noise emmissions from a digital  
apparatus set out in the Radio Interference Regulations of the Canadian Department of  
Communications.  
Le present appareil numerique n’emet pas de bruits redioelectriques depassant les limites  
applicables aux appareils numeriques de la Class A prescites dans le Reglement sur le  
brouillage redioelectrique edicte par le ministere des Communications du Canada.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Contents  
CHAPTER 1 - OPERATION  
Channel Clocking............................................................................................................................... 1-1  
Fallback Clocking............................................................................................................................... 1-1  
Channel Interface............................................................................................................................... 1-1  
Anti-streaming.................................................................................................................................... 1-2  
Channel Selection Modes .................................................................................................................. 1-2  
Channel Tail Circuits ......................................................................................................................... 1-3  
Interface Connections........................................................................................................................ 1-4  
Front Panel LEDs .............................................................................................................................. 1-4  
Channel Enable / Disable Switches .................................................................................................. 1-4  
Power Supply..................................................................................................................................... 1-4  
CHAPTER 2 - SETUP AND INSTALLATION  
Power Connection ............................................................................................................................. 2-1  
Factory Configuration Switch Settings .............................................................................................. 2-1  
Disassembly ...................................................................................................................................... 2-2  
Installation .......................................................................................................................................... 2-2  
Equipment Grounding (SW15-1) ....................................................................................................... 2-3  
RTS To CTS Delay (SW16-1,2,3)..................................................................................................... 2-3  
Anti-Streaming (SW18-1,2,3) ............................................................................................................ 2-3  
Receive Data Mode (SW18-7) .......................................................................................................... 2-3  
Control Turn-Off Delay in “DATA” Switching Mode (SW15-3,4) ....................................................... 2-4  
Switch on Data / Control (SW17-5,6,7,8).......................................................................................... 2-4  
Internal Baud Rates (SW15-5,6,7,8) ................................................................................................. 2-4  
Fallback Clock Enable (SW16-7) ...................................................................................................... 2-5  
Fallback Clocking From Sub-Channel 4 (SW16-8)........................................................................... 2-5  
Fallback Mode Selection (SW16-6) ................................................................................................... 2-5  
TX Clock Source Selection (SW17-1,2,3).........................................................................................2-6  
TX Clock Pin Selection (SW17-4) ..................................................................................................... 2-6  
RX Clock Source Selection (SW18-4,5,6) ........................................................................................ 2-6  
Tail Circuit Buffers (SW16-4) ............................................................................................................ 2-7  
Port DCE/DTE Selection (SW5 thru SW14)..................................................................................... 2-7  
DTR / DSR Forced Active (JP8 thru JP12) ....................................................................................... 2-8  
FACTORY Test Jumpers (JP1, JP2 and JP3) .................................................................................. 2-8  
APPENDIX  
Typical Application .............................................................................................................. A-1  
Typical Tail Circuit Configuration ......................................................................................... A-1  
Interface Pins Supported ..................................................................................................... A-2  
Master DTE / Sub-Channel DTE Interface Flow Diagram .................................................... A-3  
Master DTE / Sub-Channel DCE Interface Flow Diagram.................................................... A-3  
Master DCE / Sub-Channel DCE Interface Flow Diagram ................................................... A-4  
Master DCE / Sub-Channel DTE Interface Flow Diagram.................................................... A-4  
TECHNICALSPECIFICATIONS.......................................................................................... A-5  
Strapping Guide .................................................................................................................. A-6  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
CHAPTER 1 - OPERATION  
The Patton 3040/V35 (CTS MD-V.35/TCB) is a network enhancement accessory intended for  
high speed synchronous or asynchronous V.35 modem, DSU/CSU, or port sharing  
applications. The 3040/V35 (CTS MD-V.35/TCB) allows for immediate expansion of a  
system without the requirement of additional communication lines. The 3040/V35 (CTS MD-  
V.35/TCB) allows any combination of up to four V.35 DCE or DTE devices to share a single  
V.35 DCE or DTE high speed link in a point-to-point or multi-point polled network.  
Channel Clocking  
The 3040/V35 (CTS MD-V.35/TCB) is protocol transparent and operates in synchronous and  
asynchronous environments at data rates up to 2.048Mbps, depending on cable length and  
attached equipment. Clocking can be derived from the Master Port clock, (pins Y,AA for TT or  
U,W for ETT and V,X for RT), the internal clock generator or any Sub-Channel clock, (pins  
Y,AA for TT or U,W for ETT and V,X for RT).  
Fallback Clocking  
In the event of loss of an externally provided clock or optionally Sub-Channel 1 DCD becoming  
inactive, the 3040/V35 (CTS MD-V.35/TCB) has the ability to automatically fall back to the  
predetermined internal baud rate clock or the Sub-Channel 4 RX Clock (pins V,X).  
Channel Interface  
The 3040/V35 (CTS MD-V.35/TCB) has five V.35 (MR-34) female connectors located on the  
rear of the unit. Also a DB-25 connector is provided in parallel with the Master Port V.35  
connector. Each port is DCE/DTE selectable, which eliminates the need for crossover cables.  
DSR or DTR can additionally be forced to the active state individually on each Sub-Channel by  
Jumpercontrol.  
3040/V35  
SUB-CHANNEL STATUS  
ENABLE/DISABLE  
STREAM  
ACTIVE  
1
2
3
4
PW S D RD  
FB  
1
2
3
4
1
2
3
4
OPERATION  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Anti-streaming  
A typical problem often encountered is a “STREAMING” remote terminal. The streaming  
problem can tie up an entire circuit until the offending device has recovered or is powered  
down. A streaming condition occurs when a Sub-Channel remains active, disrupting the  
polling sequence. The 3040/V35 (CTS MD-V.35/TCB) provides two user selectable modes of  
controlling a streaming condition, an automatic anti-streaming Abort Timer with eight  
selectable block lengths and a setting to disable anti-streaming for large data block transfers,  
and a manual Operator Control mode (front panel push button switch).  
Automatic Anti-streaming - Automatic Anti-Streaming will block the asserted control signal  
from the Sub-Channel Port, releasing the 3040/V35 (CTS MD-V.35/TCB) to accept requests  
from any other Sub-Channel that has not been locked out due to a streaming condition. When  
a Sub-Channel is locked out for streaming, a visual indication, by Sub-Channel, is provided on  
the front panel. The Sub-Channel will no longer receive data or CTS from the Master Port.  
Any data sent to the Master Port by the streaming device will be lost. Once a Sub-Channel is  
locked out due to streaming, the Sub-Channel will remain locked out until the attached device  
removes the streaming condition. If RTS is held active, RTS must become inactive, if  
continuous data transitions have triggered the Anti-Stream logic, the transitions must stop  
before the 3040/V35 (CTS MD-V.35/TCB) will clear the Anti-Stream logic to that Sub-Channel.  
Removing the Sub-Channel via the front panel disable switch will not clear the Anti-stream  
logic for a Sub-Channel once it has been activated.  
Manual Anti-Streaming - If manual Anti-Stream protection is chosen, a streaming condition  
caused by one of the attached terminals can be quickly corrected by the 3040/V35 (CTS MD-  
V.35/TCB) via the associated front panel locking switches. A switch is provided for each Sub-  
Channel and permits the rapid removal of a streaming terminal without having to disconnect  
any cables or power down the offending terminal. Terminals may be selectively removed for  
self-test and maintenance without affecting the remaining Sub-Channels. Once the streaming  
condition has been corrected, the front panel switch is simply depressed to the locked  
(Enable) position (Green indicator ON) to re-establish normal operation. Removing a Sub-  
Channel with the front panel switch will block data from the Sub-Channel going to the Master  
Port but will not block data going from the Master Port to the Sub-Channel as the Automatic  
Anti-Stream option did.  
Channel Selection Modes  
The 3040/V35 (CTS MD-V.35/TCB) provides two selectable Sub-Channel service modes of  
operation, the Scanning Mode and Priority Mode. Depending on system requirements, either  
mode may be selected by internal DIP switch settings. Both modes switch on activity from the  
Sub-Channel.  
OPERATION  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
In the Scanning Mode the CTS 3040/V35 (CTS MD-V.35/TCB) scans each Sub-Channel, in  
sequence, beginning with Sub-Channel 1. This rotational sequence is repeated continually  
with each attached Sub-Channel having equal access to the communications link. When data  
or control lines from a Sub-Channel become active that Sub-Channel is switched through to  
the master port by the 3040/V35 (CTS MD-V.35/TCB). All remaining Sub-Channels are  
locked out until the first device becomes inactive. When the Sub-Channel device becomes  
inactive, the 3040/V35 (CTS MD-V.35/TCB) will resume scanning the Sub-Channels for  
anotheractivesignal.  
When configured for Priority Mode operation, the 3040/V35 (CTS MD-V.35/TCB) monitors all  
Sub-Channels simultaneously with Sub-Channel 1 having the highest priority. When a Sub-  
Channel becomes inactive, the 3040/V35 (CTS MD-V.35/TCB) will automatically default to the  
highestpriority(lowestnumber)Sub-Channelwithactivity.  
Contention for the Master port is accomplished by asserting RTS (Request to Send) if the  
Sub-Port is configured as a DCE, DCD (Data Carrier Detect) if the Sub-Port is configured as  
a DTE or Data Transitions from the attached Sub-Channel devices in either configuration. The  
active interface lead, RTS or DCD, as well as selection of contention mode, “Data Transitions”  
or “Interface Lead” activation, can be selected on an individual basis for each Sub-Channel.  
Once a Sub-Channel asserts an active control signal the control signal will be passed through  
to the Master Port, depending on DTE / DCE configuration of the Sub-Channel and Master  
Port. This control will be passed without delays. If the Master Port is configured as a DTE the  
signal will be passed as RTS. The CTS returned to the Master will have an optional delay  
added before the signal is returned to the Sub-Channel port.  
Port Enable / Disable, front panel switches must be pushed in (GREEN indication) for a Sub-  
Channel to access the Master Port regardless of the mode of operation selected.  
Channel Tail Circuits  
A buffer is built into the unit for tail circuit (DCE to DCE) applications. An 8 bit centered ring  
buffer is used to correct the clock phasing errors generated between the Modem on the  
Master Port and the Sub-Channel port for the data transferred from the Sub-Channel to the  
Master Port. If the unit is operated in an asynchronous environment the buffer must be  
bypassed. This is accomplished by moving the SYNC/ASYNC switch to ASYNC.  
OPERATION  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Interface Connections  
All connections are made via industry standard CCITT V.35 (MR-34) female connectors  
located on the rear of the unit. The Following interface leads are implemented, Chassis (A),  
TD (P,S), RD (R,T), RTS (C), CTS (D), DSR (E), Sig Gnd(B), DCD (F), TT (Y,AA), RT (V,X),  
DTR(H),ETT(U,W).  
In addition the master port can be accessed via an DB-25 with the following pinout, Chassis  
(1), TD (24,11), RD (23,22), RTS (4), CTS (5), DSR (6), Sig Gnd(7), DCD (8), TT (14,1), RT  
(16,3), DTR (20), ETT (15,2).  
Front Panel LEDs  
Front panel LEDs are provided to indicate power is applied, RD and TD activity from the  
Master Port, Sub-Channel activity of each individual Port, Anti-Stream condition of each Sub-  
Channel and an indication of clock Fallback condition.  
Channel Enable / Disable Switches  
Front panel switches allow operator intervention to remove an individual Sub-Channel from  
accessing the Master Port. Positive latching type switches are provided for each Sub-  
Channel port for isolating or removing a streaming terminal. The Sub-Channel is activated by  
pushing the switch until it is in the “IN” position. The switch will indicate GREEN in color. To  
disable a Sub-Channel push the switch until it locks in the “OUT” position, the switch will  
indicate BLACK in color. Disabling a Sub-Channel with the front panel does not prevent the  
Sub-Channel from receiving data from the Master Port only from sending data to the Master  
Port.  
Power Supply  
A linear power supply is located internally, an external 110/220VAC switch is located on the  
rear of the unit. If chassis ground and signal ground need to be tied together this can also be  
accomplished by switch selection. The unit is Rackmountable for 19" cabinets or optional 23"  
cabinets, by using the provided Rackmount Kit. Safety approvals granted are UL and CSA as  
well as emission approval for FCC Class A.  
OPERATION  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Caution, Disconnect the POWER Before Removing The Cover  
Vorsicht, Befor Deckung Abnehmen Mach Strom Zu.  
CHAPTER 2 - SETUP AND INSTALLATION  
Power Connection  
Before connecting the 3040/V35 (CTS MD-V.35/TCB) to a AC power source the top cover  
must be installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/  
220VAC voltage switch, turn the switch with  
110 / 220VA Switch  
a coin or screw driver to the appropriate  
voltage for your country. EXAMPLE: In  
the United States of America; set to  
110VAC. The unit is supplied with a  
IEC power connector next to the  
Fuse Drawer  
WARNING: FOR CONTINUED PROTECTION  
AGAINST RISK OF FIRE, REPLACE ONLY  
WITH SAME TYPE AND RATING FUSE.  
110  
PORT 4  
MASTER DTE/ DCE  
voltage select switch, plug the power  
cord into the connector until it is firmly  
seated. You may now connect the  
power cord into your AC outlet.  
IEC Power Connector  
Factory Configuration Switch Settings  
The 3040/V35 (CTS MD-V.35/TCB) is configured prior to shipment with the switches set to the  
followingdefaultpositions:  
Switch 15 - 1,2,3, 4 and 8 to OFF, 5, 6 and 7 to ON.  
No Data Time Out = 2048 bits  
Internal Baud Rate = 56000  
Chassis Ground not connected to Signal Ground  
Switch 16 - All to ON.  
CTS Delay = No Delay  
Sync Mode  
Contention Mode = Priority  
Fallback Clock = Disabled  
Fallback Clock Mode = Data Transitions  
Fallback Clock Source = Internal Baud Rate Generator  
Switch 17 - All to ON.  
TX Clock Source = Master pin 15  
Sub-ChannelActivityIndicatedbyInterfaceControl(RTS/DCD)  
SETUP & INSTALLATION  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Switch 18 - 1, 2, 3, 7 and 8 to OFF, 4, 5 and 6 to ON  
Anti-Stream timer = 2 M bits  
Anti-Stream = Disabled  
Broadcast Data to Sub-Channels  
RX Clock Source = Master  
JP4 Thru JP7 Open  
HS Option Not Enabled  
JP8 thru JP12 to Open  
DTR / DSR Not Forced  
JP1 Thru JP3 to Installed  
Factory Test Jumpers  
If the system application requires one or more of the default settings to be changed, it will be  
necessary to remove the top cover of the enclosure to access and change the DIP switches  
located on the printed circuit board.  
Disassembly  
Remove the top cover by removing the phillips head screws located on the left and right sides  
of the 3040/V35 (CTS MD-V.35/TCB). DTE/DCE switches SW5 through SW14, baud rate  
Jumpers JP4 through JP7, interface Jumpers JP8 through JP12 and configuration switches  
SW15 through SW18 are located on the PCB as indicated on the strapping guide in the  
Appendix of this manual. After the switch selection activity is completed, re-install the top  
cover BEFORE connecting to a AC power source.  
Installation  
Select an appropriate location accessible to and within six feet of an AC power outlet, the  
outlet must have a ground pin receptacle for product warranty. The DCE-to-DTE cabling  
between each attached device and the 3040/V35 (CTS MD-V.35/TCB) should be “Straight  
Through”, shielded and terminated with male connectors. Sub-Channels are marked PORT 1  
through PORT 4, the Master Port is marked, MASTER DCE/DTE. If any terminal has a priority  
service mode, ensure it is connected to the port connector designated “PORT 1” on the rear  
panel of the 3040/V35 (CTS MD-V.35/TCB). Secure other terminals or Modems to be  
serviced to the remaining “PORT” connectors. Connect the MODEM or TERMINAL to the  
connector designated “MASTER DTE/DCE”.  
SETUP & INSTALLATION  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Equipment Grounding (SW15-1)  
Switch SW15-1 provides for grounding interconnection in those systems requiring a  
connection between (Frame Ground) and (Signal Ground). Connect ONLY if required.  
RTS To CTS Delay (SW16-1,2,3)  
If a CTS delay is desired, set SW16-1, 2 and 3 to the required value as indicated below.  
SW16-1 SW16-2 SW16-3  
Time  
No Delay  
1mS  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
2mS  
OFF  
ON  
ON  
4mS  
OFF  
OFF  
OFF  
OFF  
8mS  
OFF  
ON  
ON  
16mS  
32mS  
64mS  
OFF  
OFF  
OFF  
Anti-Streaming (SW18-1,2,3)  
The maximum data block size is user selectable via switch SW18- 1, 2 and 3. As shown  
below eight block sizes are provided to the user. To disable anti-streaming set SW18-8 to the  
OFF position. The maximum block size is normally defined at the time of installation.  
SW18-1 SW18-2 SW18-3 CLOCKS  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
1024  
2048  
4096  
16 K  
OFF  
OFF  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
64 K  
OFF  
ON  
ON  
256 K  
1 MEG  
2 MEG  
OFF  
OFF  
OFF  
SETUP & INSTALLATION  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Receive Data Mode (SW18-7)  
Setting switch SW18-7 to ON sets the 3040/V35 (CTS MD-V.35/TCB) into the Gated Mode.  
Only the Sub-Channel that is currently active will receive the data from the master port. Setting  
position 7 to OFF enables the Broadcast mode. Receive Data from the Master Port is sent to  
allSub-Channels.  
Control Turn-Off Delay in “DATA” Switching Mode (SW15-3,4)  
When configured to switch on DATA, switch SW15-3 and 4 set the Sub-Channel release time  
in clocks. The value selected is the number of clocks at the current baud rate that must occur  
without any data transitions on the Sub-Channel to indicate that Sub-Channel has completed  
its transmission and the 3040/V35 (CTS MD-V.35/TCB) can resume servicing the other Sub-  
Channels. The following table should be used to set this time period.  
SW15-3 SW15-4 CLOCKS  
ON  
ON  
ON  
OFF  
ON  
16  
64  
OFF  
OFF  
256  
2048  
OFF  
Switch on Data / Control (SW17-5,6,7,8)  
Each sub-channel is independently selectable for switch on data or switch on an active  
interface control lead. Set SW17 pos 5 to OFF if sub-channel 1 switch on Data is required.  
Set pos 5 to ON if switch on interface control lead is desired. Position 6 thru 8 are associated  
withsub-channels2thru4.  
Internal Baud Rates (SW15-5,6,7,8)  
Switch SW15-5, 6, 7 and 8 select the master clock rate when Internal Clock Source is selected  
on TX Clock Source or RX Clock Source. In addition the Fallback clock rate is also selected  
with this option. When Fallback clocking is required, the RX Clock Source and TX Clock  
Source should not be set to INTERNAL. SW15-5, 6, 7 and 8 selects the clock rate of the  
Fallback Clock when Internal Clock Fallback is selected. The following table shows the  
available rates.  
SETUP & INSTALLATION  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
SW15-5 SW15-6 SW15-7 SW15-8  
Rate  
HS Opt.  
768K  
384K  
192K  
128K  
72K  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
64K  
OFF  
ON  
ON  
57.6K  
56K  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
ON  
48K  
OFF  
OFF  
ON  
ON  
38.4K  
28.8K  
19.2K  
14.4K  
9.6K  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
4.8K  
For the High Speed Option set SW15-5, 6, 7 and 8 to ON and select the desired rate by  
installing JP4 for 2048K, JP5 for 1024K, JP6 for 512K or JP7 for 256K. Only one of the four  
jumpers should be installed of proper operation.  
Fallback Clock Enable (SW16-7)  
If Clock Fallback is required when the primary clock fails, set switch SW16-7 to OFF. If  
Fallback is not required set SW16-7 to ON. The Fallback clock rate is selected with the  
internal baud rate option. When the Fallback is activated the FBC LED will illuminate.  
Fallback Clocking From Sub-Channel 4 (SW16-8)  
To use the Sub-Channel 4 RX Clock as the Fallback clock set SW16-8 to OFF. To use the  
Internal Baud Rate Clock as the Fallback clock set SW16-8 to ON.  
Fallback Mode Selection (SW16-6)  
If Fallback is required, two modes are available via switch SW16-6. To Fallback when the  
transitions from the primary clock source stop, set SW16-6 to ON. To Fallback when DCD on  
Sub-Channel 1 becomes inactive, set SW16-6 to OFF.  
SETUP & INSTALLATION  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
NOTE: Both TX and RX Clock Source Select MUST Be Set !!!!  
TX Clock Source Selection (SW17-1,2,3)  
TX Clock Source is selected by switch SW17-1, 2 and 3. The following table indicates the  
source options provided by the 3040/V35 (CTS MD-V.35/TCB). When using the unit in Async  
Mode, the INTERNAL clock source must be selected.  
SW17-1 SW17-2 SW17-3  
Source  
Master  
Port 1  
Port 2  
Port 3  
Port 4  
unused  
unused  
Internal  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
Internal Must Be Selected For  
Async Operation  
OFF  
TX Clock Pin Selection (SW17-4)  
The primary transmit clock can be derived from either pins Y,AA or pins U,W. If pins Y,AA are  
to be the source for primary TX Clock, set SW17-4 to ON. If pins U,W are to be the source for  
primary TX & RX Clock, set SW17-4 to OFF.  
RX Clock Source Selection (SW18-4,5,6)  
RX Clock Source is selected by SW18-4, 5 and 6. The following table indicates the source  
options provided by the 3040/V35 (CTS MD-V.35/TCB). If the TXC source is pins U,W, both  
RXC and TXC will be sourced from pins U,W. When the unit is used in an Async network  
select INTERNAL as the source of the RX Clock.  
SW18-4 SW18-5 SW18-6  
Source  
Master  
Port 1  
Port 2  
Port 3  
Port 4  
unused  
unused  
Internal  
ON  
OFF  
ON  
ON  
ON  
ON  
ON  
OFF  
OFF  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
OFF  
SETUP & INSTALLATION  
2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Tail Circuit Buffers (SW16-4)  
The 3040/V35 (CTS MD-V.35/TCB) has a Tail Circuit Buffer that is automatically selected  
when a Sub-Channel is set as a DTE. The buffer will provide clock synchronization of the data  
from the Sub-Channel to the Master Port for Tail Circuit operations. The buffer is de-activated  
when the Sub-Channel is configured as a DCE. When operating in an asynchronous  
environment the Buffer must be bypassed. To bypass the buffer in a synchronous or  
asynchronous application, set switch SW16-4 to OFF (ASYNC). For normal operation in a  
synchronous environment set SW16-4 to ON (SYNC). When using a tail circuit modem with  
the 3040/V35 (CTS MD-V.35/TCB), the modem connected to the Sub-Channel, should be set  
to External Transmit Clocking. The modem at the remote end of the connection should be set  
to RX-TX Clocking or Slaved TX Clock. This will insure the same clock is present throughout  
the network and clock slippage will not occur.  
Port DCE/DTE Selection (SW5 thru SW14)  
Slide switches SW5 through SW14 are used to configure DTE/DCE for each port. Slide Both  
switches associated with a port to the same position. Example: If connecting a modem (DCE  
Device) to the PORT, then the port should be configured as a DTE interface. Slide both  
switches to the DTE position toward the interface connector. If connecting a terminal (DTE) to  
the Sub-Channel, the port should be configured as a DCE. Slide both switched to the DCE  
position away from the interface connector. The port is always configured opposite to the  
interface that is to be connected to it.  
DCE  
J8 thru JP12  
DCE  
Forced DSR/DTR  
SETUP & INSTALLATION  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
DTR / DSR Forced Active (JP8 thru JP12)  
DTR is tied to DSR on each of the Sub-Channel ports. If the device connected does not  
supply a DTR but requires DSR (DTE) or does not supply DSR but requires DTR (DCE),  
installing the forced DTR/DSR jumper (JP8-JP12) for the appropriate Sub-Channel will solve  
this problem. The line is forced to +8V via an 820W resistor, providing isolation to any driver  
that might be on the interface.  
Channel Jumper Channel  
Jumper  
JP11  
Master  
JP8  
JP9  
3
4
1
2
JP12  
JP10  
FACTORY Test Jumpers (JP1, JP2 and JP3)  
The three test jumpers JP1, 2 and 3, must be installed for the unit to properly function. These  
jumpers are used in the manufacture and test of the product prior to shipment.  
SETUP & INSTALLATION  
2-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
APPENDIX  
V.35  
V.35  
Leased  
or  
Dial Line  
V.35 DSU/CSU  
V.35  
Leased  
or  
3040/V35  
Dial Line  
V.35 DSU/CSU  
3040/V35  
Typical Application  
External  
TX Clocking  
Slave  
TX Clocking  
ETT-U,V  
Data  
Data  
Data  
Data  
ETT-U,W  
RT-V,X  
TT-Y,AA  
TT-Y,AA  
Data  
RT-V,X  
RT-V,X  
Slave  
ETT-U,W  
TT-Y,AA  
TX Clocking  
Internal  
RT-V,X  
TX Clocking  
Terminal  
Buffer  
Data  
Data  
Typical Tail Circuit Configuration  
APPENDIX  
A-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
SG  
CD  
RD(A)  
RT(A)  
B
F
L
R
V
Z
DD  
CC  
JJ  
NN  
CTS  
RD(B)  
RT(B)  
D
J
N
T
X
BB  
FF  
EE  
LL  
FG  
DSR  
TD(A)  
ETT(A)  
TT(A)  
A
E
K
P
U
Y
HH  
M M  
RTS  
DTR  
TD(B)  
ETT(B)  
TT(B)  
C
H
M
S
W
AA  
KK  
M-34 Interface Pins Supported  
DB-25 V.35  
1 Transmit Clock(B) (from DCE)  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
Transmit Clock(A) (from DCE)  
2 External Transmit Clock(B) (from DTE)  
External Transmit Clock(A) (from DTE)  
Receive Clock(A) (from DCE)  
Receive Clock(B) (from DCE)  
3
4 Request to Send (from DTE)  
Clear To Send (from DCE)  
Data Set Ready (from DCE)  
Signal Ground (common)  
5
6
7
Data Terminal Ready (from DTE)  
Data Carrier Detect (from DCE)  
8
9
Receive Data(B) (from DCE)  
Receive Data(A) (from DCE)  
Transmit Data(A) (from DTE)  
10  
11  
12  
13  
Transmit Data(B) (from DTE)  
DB-25 Interface Pins Supported  
APPENDIX  
A-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Master Port is a DTE  
Channel Port is a DTE  
Pins R,T RD  
Pins P,S TD  
Pin C RTS  
Pin D CTS  
Pin E DSR  
Pin F DCD  
Pins P,S TD  
Buffer  
Pins R,T RD  
+8v  
Clk Out  
Clk In  
Pin C RTS  
Pin D CTS  
Pin E DSR  
Pin F DCD  
Pin H DTR  
Pins Y,AA TT  
Switch Control  
Master TX Clock  
Selection Logic  
Pin H DTR  
Pins Y,AA TT  
Pins V,X RT  
Master RX Clock  
Selection Logic  
Pins V,X RT  
Pins U,W ETT  
Pins U,W ETT  
Master DTE / Sub-Channel DTE Interface Flow Diagram  
Channel Port is a DCE  
Pins R,T RD  
Master Port is a DTE  
Pins R,T RD  
Pins P,S TD  
Pin C RTS  
Pins P,S TD  
Switch Control  
Pin C RTS  
Pin D CTS  
Pin D CTS  
Pin E DSR  
Pin F DCD  
Pin H DTR  
Pins Y,AA TT  
Pin E DSR  
Pin F DCD  
Pin H DTR  
Master TX Clock  
Selection Logic  
Pins Y,AA TT  
Pins V,X RT  
Pins V,X RT  
Master RX Clock  
Selection Logic  
Pins U,W ETT  
Pins U,W ETT  
Master DTE / Sub-Channel DCE Interface Flow Diagram  
APPENDIX  
A-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
Channel Port is a DCE  
Master Port is a DCE  
Pins P,S TD  
Pins R,T RD  
Pins R,T RD  
Pins P,S TD  
Switch Control  
Pin C RTS  
Pin C RTS  
Pin D CTS  
Pin D CTS  
Pin E DSR  
Pin E DSR  
+8v  
Pin F DCD  
+8v  
Pin F DCD  
Pin H DTR  
Pin H DTR  
Master TX Clock  
Selection Logic  
Pins Y,AA TT  
Pins Y,AA TT  
Pins V,X RT  
Pins V,X RT  
Master RX Clock  
Selection Logic  
Pins U,W ETT  
Pins U,W ETT  
Master DCE / Sub-Channel DCE Interface Flow Diagram  
Channel Port is a DTE  
Master Port is a DCE  
Pins P,S TD  
Pins P,S TD  
Pins R,T RD  
Pin C RTS  
Pin D CTS  
Pin E DSR  
Pin F DCD  
Pin H DTR  
Pins Y,AA TT  
Pins R,T RD  
Pin C RTS  
Pin D CTS  
Pin E DSR  
Buffer  
+8v  
Clk Out  
Clk In  
Switch Control  
+8v  
Pin F DCD  
Pin H DTR  
Master TX Clock  
Selection Logic  
Pins Y,AA TT  
Pins V,X RT  
Master RX Clock  
Selection Logic  
Pins V,X RT  
Pins U,W ETT  
Pins U,W ETT  
Master DCE / Sub-Channel DTE Interface Flow Diagram  
APPENDIX  
A-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PATTON ELECTRONICS CO.  
3040/V35  
INSTALLATION AND OPERATIONS MANUAL  
139001UA  
TECHNICAL SPECIFICATIONS  
Applications  
Sub-Channel Interface  
Multiple V.35 Sync or Async DCE or DTE devices  
sharing one V.35 DCE or DTE link  
CCITT V.35 female connectors (MR-34)  
Master Interface  
Capacity  
CCITT V.35 female connector (MR-34 & DB-25)  
One to Four V.35 Sync or Async DTE or DCE  
devices One V.35 DCE or DTE Master Channel  
Front Panel  
Data Format  
Indicators: ..... Power, Send Data, Receive Data,  
ClockFallback,Sub-ChannelActive,  
Data transparent at all data rates  
Data Rates  
Sub-ChannelStream  
Switches: ...... Enable/DisableeachSub-Channel  
Power Source  
Up to 2.048Mbps  
Timing  
100-120/200-240 Vac, 50 to 60 Hz, 0.16/0.08  
A, Switch Selectable  
Environmental  
Internal: ......DIP switch selectable  
Normal: ...... FromModem  
External:......Clock provided on any Sub-Channel  
OperatingTemp: .......32° to 122°F (0° to 50°C)  
RelativeHumidity: .....5 to 90% non-condensing  
Altitude: ..................0 to 10,000 feet  
Anti-streaming  
Dimensions  
Automatic:Selectabletimeoutintervalsordisable  
Terminal Service Modes  
Height: .......1.75 inches (4.44 cm)  
Width: .......17.00 inches (43.18 cm)  
Length: .......11.00 inches (18.93 cm)  
ScanningMode:...... Channels are continuously  
scanned for activity on a  
Weight  
sequentialbasis.  
Priority Mode: ........ Channels are simultaniously  
monitored channel one has  
4.5 lbs (2.1 Kg)  
highestaccess  
APPENDIX  
A-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
J2  
J3  
J4  
J5  
J6  
J1  
JP8 thru JP12 Installed forces DTR/DSR for the channel  
V.35 on DB-25  
SW5 SW6  
SW7 SW8  
SW9 SW10  
SW11 SW12  
SW13 SW14  
No Data Timer - SW15  
Count  
ON ON 16  
ON OFF 64  
OFF ON 256  
OFF OFF 2048  
3
4
DTE  
DCE  
JP8  
JP9  
JP10  
JP11  
JP12  
SW15  
SW16  
SW17  
SW18  
CTS Delay Timer - SW16  
Signal to Chassis Ground  
Unused  
1
2
3
Delay  
Tx Clock Source  
CTS Delay  
Anti-Stream Timer  
Rx Clock Source  
ON ON ON No Delay  
OFF ON ON 1 mS  
ON OFF ON 2 mS  
OFF OFF ON 4 mS  
ON ON OFF 8 mS  
OFF ON OFF 16 mS  
ON OFF OFF 32 mS  
OFF OFF OFF 64 mS  
No Data Timeout  
TXC pinsY,AA=ON / pinsU,W=OFF  
Ch1 RTS=ON /Data=OFF  
Ch2 RTS=ON /Data=OFF  
Ch3 RTS=ON /Data=OFF  
Ch4 RTS=ON /Data=OFF  
Sync=ON /Async=OFF  
Priority=ON /Scan=OFF  
FB on CLK=ON /FB on DCD=OFF  
FB Disable=ON /FB Enable=OFF  
Int Clk FB=ON /Ch4 FB=OFF  
Baud Rate Selection  
Rcvr Gated=ON /Broadcast=OFF  
Anti-Stream Enabled=ON  
OF F ON  
OF F ON  
OF F ON  
OF F ON  
Baud Rate Select - SW15  
Rate  
TX Clock Source - SW17  
Source  
RX Clock Source - SW18  
Source  
Anti-Stream Timer - SW18  
5
6
7
8
1
2
3
4
5
6
1
2
3
Count  
ON ON ON ON HS Option  
OFF ON ON ON 768K  
ON OFF ON ON 384K  
OFF OFF ON ON 192K  
ON ON OFF ON 128K  
OFF ON. OFF ON. 72K  
ON OFF OFF ON. 64K  
OFF OFF OFF ON 57.6K  
ON ON ON OFF 56K  
OFF ON. ON OFF 48K  
ON. OFF ON OFF 38.4K  
OFF OFF ON OFF 28.8K  
ON. ON OFF OFF 19.2K  
OFF ON. OFF OFF 14.4K  
ON. OFF OFF OFF 9.6K  
OFF OFF OFF OFF 4.8K  
ON ON ON Master  
OFF ON ON Chan1  
ON OFF ON Chan2  
OFF OFF ON Chan3  
ON ON OFF Chan4  
OFF ON OFF Unused  
ON OFF OFF Unused  
OFF OFF OFF Internal  
ON ON ON Master  
OFF ON ON Chan1  
ON OFF ON Chan2  
OFF OFF ON Chan3  
ON ON OFF Chan4  
OFF ON OFF Unused  
ON OFF OFF Unused  
OFF OFF OFF Internal  
ON ON ON 1024  
OFF ON ON 2048  
ON OFF ON 4096  
OFF OFF ON 16K  
ON ON OFF 64K  
OFF ON OFF 256K  
ON OFF OFF 1M  
OFF OFF OFF 2M  
JP3  
JP2  
HS Option  
256Kbps  
JP7  
JP6  
JP5  
JP4  
512Kbps  
1024Kbps  
2048Kbps  
JP1  
Port Enable(Green) / Disable(Black)  
Fall  
Back  
Power SD RD  
Clocking  
Active Anti-Stream  
1 2 3 4  
1 2 3 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B
7622 Rickenbacker Drive  
Gaithersburg, MD 20879  
Sales: 301 975-1000  
Support: 301 975-1007  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Power Screwdriver ESW4802Vi User Manual
Nikon Telescope 25 8x25 EER User Manual
N Tron Switch 524TX A User Manual
Oki Printer 8w Lite User Manual
Omega Engineering Smoke Alarm ISD9001 User Manual
Onkyo Stereo System HT S5100 User Manual
Palsonic Flat Panel Television TFTV490HD User Manual
Panamax Surge Protector PM8 EX User Manual
Panasonic Network Card 2SD1821G User Manual
Panasonic Telephone 44 Series User Manual