For Quick
For Quick
Start Installation
Start Installation
SmartNode 4400
IpChannel Bank
Quick Start Guide
Important
This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial
or residential environment.
Sales Office: +1 (301) 975-1000
Technical Support: +1 (301) 975-1007
E-mail: [email protected]
WWW: www.patton.com
Part Number: 07MSN4400-QS, Rev. B
Revised: January 13, 2010
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
Safety when working with electricity
The SmartNode contains no user serviceable parts. The equipment shall be
returned to Patton Electronics for repairs, or repaired by qualified service per-
sonnel. Opening the SmartNode case will void the warranty.
Mains Voltage: Do not open the case the when the power cord is attached.
Line voltages are present within the power supply when the power cords are
connected. The mains outlet that is utilized to power the device shall be
within 10 feet (3 meters) of the device, shall be easily accessible, and pro-
tected by a circuit breaker.
For AC powered units, ensure that the power cable used meets all applicable
standards for the country in which it is to be installed, and that it is connected
to a wall outlet which has earth ground.
The Model SN4400 is not shipped with power cables. For AC powered units,
ensure that the power cable used meets all applicable standards for the coun-
try in which it is to be installed, and that it is connected to a wall outlet which
has earth ground.
Hazardous network voltages are present in WAN ports regardless of whether
power to the SmartNode is ON or OFF. To avoid electric shock, use caution
when near WAN ports. When detaching the cables, detach the end away from
the SmartNode first.
Because telephone line voltages can be dangerous, when detaching the net-
work cables, disconnect the end away from the SmartNode first.
Do not work on the system or connect or disconnect cables during periods of
lightning activity.
In accordance with the requirements of council directive 2002/
96/EC on Waste of Electrical and Electronic Equipment (WEEE),
ensure that at end-of-life you separate this product from other
waste and scrap and deliver to the WEEE collection system in
your country for recycling.
Safety when working with electricity
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
Introduction
This Quick Start Guide leads you through the basic steps to set up a new SmartNode and to download a con-
figuration. Please note that this guide does not replace the detailed Software Configuration Guide and the Get-
SmartNodes can be used for a wide variety of IP and voice over IP applications. To support and ease the config-
uration of the SmartNodes, configuration templates for the most important applications are available online at
Setting up a new SmartNode consists of the following steps:
1. Attach the power cable retainer clip to the unit
4. Download a configuration example, adapt it to your network, and load it onto the SmartNode (see page 8)
Attaching the cable retainer clip
To secure the power cord, it is necessary to attach the metal retainer clip (if applicable to your model). Squeeze
the clip and insert into the holes in the screws on either side of the power connector on your unit. The clip will
pop into place.
Power cable
retainer clip
Figure 1. Attaching the cable retainer clip
Note Refer to the Getting Started Guide on the CD-ROM or on the Patton
website for detailed instrauctions about grounding and connecting
power to your unit.
Introduction
4
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
Connecting a PC, logging in, and configuring the LAN IP address
Connecting power and configuring the default IP address
Connect the SmartNode to the mains power supply using the included power supply and cable. When the
RUN LED stops blinking and remains lit, the SmartNode is ready.
The factory default IP settings are listed in table 1. If these addresses do not work with your network they must
be changed. Contact your network administrator if you are not sure which IP address to use in
your installation.
Table 1. Factory default IP address and network mask configuration
Item
IP Addresss(es)
Network Mask
WAN interface Ethernet 0 (ETH 0/0)
LAN interface Ethernet 1 (ETH 0/1)
DHCP server address range
DHCP
DHCP
192.168.1.1
255.255.255.0
255.255.255.0
192.168.1.10-192.168.1.19
Note The DHCP server is running on the ETH 0/1 of the SN4400 Series
models. All Ethernet ports are pre-configured and active.
Connecting to a PC and logging in
1. To access the SmartNode configuration, connect a PC equipped with an RS-232 console port to the Con-
sole port on the front of the SmartNode. Use the included black Ethernet cable and RJ45 to DB-9 adapter
for this purpose (Model 16F-561).
AL SUPPLIES
NG
H SUICPIPLIES
V
WITH U
UIPPED
BEFORE SER
DISCONNECT BO
UNIT EQ
100-240V
-60 Hz)
AMP
s
t
r
o
c
P
Console
Reset
Console port
ETH 0/0
ETH 0/1
Model 16F-561
adapter and cable
Laptop PC
Figure 2. Connecting to the PC
2. Open a Terminal connection to the SmartNode. Use the Terminal program included with most PC operat-
ing systems (e.g. Hyper Terminal on Windows). The CD-ROM also includes some recommended termi-
nal programs.
Connecting a PC, logging in, and configuring the LAN IP address
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
3. Type administrator as the login prompt and press the Enter key after the password prompt (do not type
anything for the password). A prompt will appear consisting of the IP address and > character.
login:administrator
password:
172.16.40.1>
4. Following log in, the SmartNode is in operator execution mode (indicated by > character in the command
line prompt). With the commands enable and configure, you enter the configuration mode.
172.16.40.1>enable
172.16.40.1#configure
172.16.40.1(cfg)#
Changing the IP address
1. Select the context IP mode to configure an IP interface.
172.16.40.1(cfg)#context ip router
172.16.40.1(ctx-ip)[router]#
2. Set the IP address and network mask for the each IP interface (eth0, for example).
Note For the examples in this guide, a private network (172.16.1) IP
address is used.
172.16.40.1(ctx-ip)[router]#interface eth0
172.16.40.1(if-ip)[eth0]#ipaddress 172.16.1.10 255.255.255.0
2002-10-29T00:09:40 : LOGINFO
2002-10-29T00:09:40 : LOGINFO
172.16.1.10(if-ip)[eth0]#
: Link down on interface eth0.
: Link up on interface eth0.
3. Make this modified configuration your new start-up configuration. On the next start-up the system will
initialize itself using the modified configuration.
172.16.1.10 (if-ip)[eth0]#copy running-config startup-config
172.16.1.10 (if-ip)[eth0]#
your network.
Connecting a PC, logging in, and configuring the LAN IP address
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
Connecting the SmartNode to the LAN
The 4400 Ethernet ports are auto MDX, therefore a straight-through wired cable can be used for host and
ES
AL SUPPLI
TH SUPPLIES
WITDU VICING
UIPPED
BEFORE SER
DISCONNECT BO
UNIT EQ
ts
or
o
P
Console
Reset
ETH 0/0
ETH 0/1
WAN
(ETH 0/0)
LAN
Network
interface
LAN (ETH 0/1)
PC or workstation
or Telnet
Internet or
WAN (optional)
Figure 3. Connecting the SmartNode to the network
You can check the connection with the ping command to another host on the local LAN.
172.16.1.99(if-ip)[eth0]#ping <IP Address of the host>
Respectively from the host: ping 172.16.1.99
Note To ping outside your local LAN, you will need to configure the
default gateway.
You may now start to configure the SmartNode from scratch using the CLI commands, but we recommend
that you start your configuration from a template. See “Downloading a configuration example, adapting it to
For a detailed description of the CLI refer to the SmartWare Software Configuration Guide (SCG) available on
Connecting the SmartNode to the LAN
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
Downloading a configuration example, adapting it to your network,
and loading it onto the SmartNode
Patton provides a collection of configuration templates on the CD-ROM that came with the SmartNode
lar enough to your application that you can use it to speed up configuring the SmartNode. Simply download
the configuration note that matches your application to your PC. Adapt the configuration as described in the
configuration note to your network (remember to modify the IP address) and copy the modified configuration
to a TFTP server. The SmartNode can now load its configuration from this server.
Note Patton regularly adds new configuration templates to the collection at
tion on the CD-ROM, it may have been added to the website.
Note If your application is unique and not covered by any of Patton’s configura-
tion templates, you can manually configure the SmartNode instead of load-
ing a configuration file template. In that case, refer to the SmartNode Series
SmartWare Software Configuration Guide for information on configuring the
SmartNode device.
In this example we assume the TFTP server on the host with the IP address 172.16.1.11 and the configuration
named SN.cfg in the root directory of the TFTP server.
172.16.1.99(if-ip)[eth0]#copy tftp://172.16.1.11/SN.cfg startup-config
Download...100%
172.16.1.99(if-ip)[eth0]#
After the SmartNode has been rebooted the new startup configuration will be activated.
When you issue the reload command, the SmartNode will ask
if you want to copy the running configuration to the startup con-
figuration. Since you just downloaded a configuration file to the
startup configuration you must answer this question with NO.
Otherwise, the downloaded configuration will be overwritten
and lost!
IMPORTANT
172.16.1.99(if-ip)[eth0]#reload
Running configuration has been changed.
Do you want to copy the 'running-config' to the 'startup-config'?
Press 'yes' to store, 'no' to drop changes : no
Press 'yes' to restart, 'no' to cancel : yes
The system is going down
Additional information
For detailed information about configuring and operating guidance, set up procedures, and troubleshooting,
refer to the SmartNode Series SmartWare Software Configuration Guide and the SmartNode Getting Started Guide
find numerous freeware and shareware tools, including TFTP servers, Telnet clients, etc..
Downloading a configuration example, adapting it to your network, and loading it onto the SmartNode
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
Compliance
EMC compliance:
• FCC Part 15, Class A
• EN55022, Class A
• EN55024
• EN-61000-3-2 Harmonics
• EN-61000-3-3 Flicker
• EN-61000-4-2 ESD
• EN-61000-4-3 Radiated Immunity
• EN-61000-4-4 EFT
• EN-61000-4-5 Surge
• EN-61000-4-6 Low Frequency Common Immunity
• EN-61000-4-11 Voltage Dips and Sags
Safety compliance:
• UL60950-1/CSA C22.2 No. 60950-1
• IEC/EN 60950-1
• AS/NZS 60950-1
CE Declaration of Conformity
This equipment conforms to the requirements of Council Directive 1999/5/EC on the approximation of the
laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual rec-
ognition of their conformity.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the
above directive is indicated by CE sign on the device.
Authorized European Representative
D R M Green
European Compliance Services Limited.
Avalon House, Marcham Road
Abingdon,
Oxon OX14 1UD, UK
Compliance
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
NOTES
NOTES
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
NOTES
NOTES
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SmartNode 4400 Quick Start Guide
NOTES
NOTES
12
Download from Www.Somanuals.com. All Manuals Search And Download.
|