USER
MANUAL
MODEL 1030
and 1030S
Synchronous, Carrier
Controlled Short
Range Modem
Part #07M1030-C
Doc. #041013UC
Revised 4/20/98
SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
C
E
R
T
I
F
I
E
D
An ISO-9001
Certified Company
Download from Www.Somanuals.com. All Manuals Search And Download.
2.0 GENERAL INFORMATION
3.0 CONFIGURATION
Thank you for your purchase of this Patton Electronics product.
This product has been thoroughly inspected and tested and is
warranted for One Year parts and labor. If any questions or problems
arise during installation or use of this product, please do not hesitate to
contact Patton Electronics Technical Support at (301) 975-1007.
The Model 1030 provides seven configuration switches, which
allow selection of carrier control method, clocking method, RTS/CTS
delay and data rate. This section describes switch locations and
explains all possible switch configurations.
3.1 SWITCH LOCATIONS
2.1 FEATURES
For your convenience, all configuration switches are located on a
SIP (single in-line package) mounted on the PC board. Figure 1 shows
the location of the SIP with respect to other PC board components. For
instructions on opening the Model 1030 case, see Section 4.1.2.
• Point-to-point or multipoint operation
• Internal, external or receive loopback clocks (switch selected)
• Data rates to 19,200 bps
• Range to 11 miles
• Carrier “on” or “controlled” (switch selected)
• Options for easy daisy chain installation
• Full or half duplex operation
Terminal
Patton
Block
VLSI chip
X X X X
• Transformer isolated
P E 0 6 8
N O T P A T
• Custom VLSI chip filters each data rate separately
• Built-in Silicon Avalanche Diode surge protection
Isolating
Transformers
Control
Switches
2.2 DESCRIPTION
The Patton Electronics Model 1030 synchronous, multipoint
short range modem provides exceptional versatility in a compact
package. Measuring only 2.66” x 2.10” x and 0.73”, the Model 1030 is
suitable for many applications where connection space is limited. The
Model 1030 supports up to twelve drops, and requires no AC power or
batteries for operation.
Figure 1. Model 1030 PC board showing switches
Operating at switch selectable data rates between 1.2 and 19.2
Kbps, the Model 1030 can attain distances between 3.5 and 8.5 miles
over two 24 AWG twisted pair (thicker gauges may yield better
distances). The Model 1030 operates half duplex or full duplex, and
accommodates three clocking methods: internal, external and received
loopback. Transformer isolation guards the Model 1030 against
ground looping in building-to-building applications. Other features
include a selectable RTS/CTS delay of 7 mSec or 53 mSec, and
selectable carrier status of constantly on or RTS controlled.
Figure 2 shows the orientation of the switches on the SIP, including
ON/OFF position.
OFF
1
2
3
4
5
6
7
8
ON
The Model 1030S is a surge protected version of the Model 1030
that uses Silicon Avalanche Diodes to provide 600 watts of transient
protection per wire.
Figure 2. Close up of configuration switches
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 SWITCH SETTINGS
Switch 5: RTS/CTS Delay
All possible settings for the Model 1030’s configuration switches
are presented in the summary table and descriptions below. If you
have additional questions regarding configuration, contact Patton
Technical Support at (301) 975-1007.
After request to send (RTS) is raised by the host terminal, the
Model 1030 raises CTS after a slight delay in order to give the remote
terminal time to receive an incoming signal. Depending on the type of
environment, either a 7mS or 53mS delay can be selected.
SWITCH SUMMARY TABLE
Switch 5
On
Off
Setting
7 mS (Default)
53 mS
Position
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
Function
Not Used
Factory Default
Off
On
Off
On
On
On
Off
Off
Not Used
Carrier Enable
Transmit Clock
Transmit Clock
RTS/CTS delay
Data Rate
Constant Carrier
Switches 6, 7 and 8: Data Rate
Internal
Clock
}
Switches 6 thru 8 are set in combination to allow the Model 1030 to
be used at data rates from 1200 bps to 19,200 bps.
7 mSec delay
Switch 6
On
On
On
Off
Switch 7
On
On
Off
On
Switch 8
On
Off
On
On
Setting
1.2 Kbps
2.4 Kbps
4.8 Kbps
9,600 bps
Data Rate
}
Data Rate
7.2 Kbps
On
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
9.6 Kbps (Default)
14.4 Kbps
19.2 Kbps
19.2 Kbps
Switch 1: Not used
Switch 2: Carrier Enable
Switch 2 is used to specify how the carrier signal is raised. In most
point-to-point, full duplex applications, the carrier signal can remain
constantly “high”. In a multi-point environment, contention for the line is
“controlled” by RTS.
Switch 2
On
Off
Setting
Constant Carrier (Default)
Controlled by RTS
Switches 3 and 4: Transmit Clock
Switches 3 and 4 are used together to specify the clocking method.
The Model 1030 can provide an internal clock (Pin 15), receive an
external clock (from Pin 24), or loopback a received clock.
Switch 3
On
On
Off
Off
Switch 4
On
Off
On
Off
Setting
External Clock
External Clock
Internal Clock (Default)
Receive Loopback
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.
4.0 INSTALLATION
When connecting two Model 1030s, it is necessary to use a
“crossover” cable. The diagram below shows how a crossover cable
should be constructed for an environment where both Model 1030s use
a 6-wire RJ-11 connector. Similar logic should be followed when using
RJ-45 connectors or a combination of the two.
Once the Model 1030 is properly configured, it is ready to connect
to your system. This section tells you how to properly connect the
Model 1030 to the twisted pair and RS-232 interfaces, and how to
operate the Model 1030.
SIGNAL PIN#
COLOR
COLOR PIN#
SIGNAL
4.1 CONNECTION TO THE TWISTED PAIR INTERFACE
GND†
RCV◊
XMT
XMT
RCV
GND
1
2
3
4
5
6
Blue‡ ................White
Yellow ..............Red
Green...............Black
Red..................Yellow
Black................Green
White ...............Blue
6
4
5
2
3
1
GND
XMT
RCV
RCV
XMT
GND
The Model 1030 supports data-only communication between two
RS-232 devices at distances to 11 miles and data rates to 19.2 Kbps.
There are two essential requirements for installing the Model 1030:
1. These units work in pairs. Therefore, you must have one Model
1030 at each end of a two twisted pair interface.
†Connection to ground is optional
2. To function properly, the Model 1030 needs two twisted pairs of
metallic wire. These pairs must be unconditioned, dry metallic
wire, between 19 and 26 AWG (the higher number gauges may
limit distance somewhat). Standard dial-up telephone circuits, or
leased circuits that run through signal equalization equipment, are
not acceptable.
‡Standard color codes—yours may be different
◊
The Model 1030 is not sensitive to polarity
1 - Blue
2 - Orange
3 - Black
4 - Red
1 - Blue
2 - Yellow
3 - Green
4 - Red
For your convenience, the Model 1030 is available with three
different twisted pair interfaces: RJ-11 jack, RJ-45 jack and terminal
blocks with strain relief.
5 - Green
6 - Yellow
7 - Brown
8 - Slate
5 - Black
6 - White
Standard AT&T color codes
4.1.1 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45
The RJ-11 and RJ-45 connectors on the Model 1030’s twisted pair
interface are pre-wired for a standard TELCO wiring environment. The
signal/pin relationships are shown below:
4.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS
If your application requires you to connect two pair of bare wires to
the Model 1030, you will need to open the case to access the terminal
blocks. The instructions on the following pages will tell you how to
open the case, connect the bare wires to the terminal blocks, and
fasten the strain relief collar in place so that the wires won’t pull loose.
RJ-11
SIGNAL
RJ-45
SIGNAL
1...................GND†
2...................RCV‡
3...................XMT
4...................XMT
5...................RCV
6...................GND
1 .................N/C
2 .................GND†
3 .................RCV‡
4 .................XMT
5 .................XMT
6 .................RCV
7 .................GND
8 .................N/C
†Connection to ground is optional
‡The Model 1030 is not polarity sensitive
7
8
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Open the unit by gently inserting a screwdriver between the
DB-25 connector and the lip of the plastic case (see below).
You don’t have to worry about breaking the plastic, but be
careful not to bend the D-sub connector.
4. Connect one pair of wires to the two XMT (transmit) poles on
the terminal block. The Model 1030 is not polarity sensitive,
so either wire may connect to either pole.
5. Connect the other pair of wires to the two RCV (receive) poles
on the terminal block. The Model 1030 is not polarity
sensitive, so either wire may connect to either pole.
Ultimately, you will want to construct a two pair crossover
cable that makes a connection with the two Model 1030s as
shown below:
XMT
XMT
G
RCV
RCV
RCV
RCV
G
XMT
XMT
One Pair
One Pair
}
}
To Shield (Optional)
6. If there is a shield around the telephone cable it may be
connected to “G” on the terminal block. To avoid ground
loops, we recommend connecting the shield at the computer
end only. A ground wire is not necessary for proper operation
of the Model 1030.
Once the unit has been opened, you will be able to see the
terminal blocks located at the rear of the PC board.
7. When you finish connecting the wires to the terminal block, the
assembly should resemble the diagram below:
2. Strip the outer insulation from the twisted pairs about one inch
from the end.
3. Strip back the insulation on each of the 2 twisted pair wires
about .25”.
9
10
Download from Www.Somanuals.com. All Manuals Search And Download.
8. Place the 2 halves of the strain relief assembly on either side
of the telephone wire and press together very lightly. Slide the
assembly so that it is about 2 inches from the terminal posts
and press together firmly. If your cable diameter is too small or
too large for our strain relief, please contact our technical
support. We have strain relief assemblies to accommodate
most cable diameters.
10. Place the top half of the case as necessary to slide it over the
strain relief assembly. Do not snap the case together yet.
11. Insert one captive screw through a saddle washer. Then insert
the entire piece through the hole in the DB-25 end of the case.
Snap that side of the case closed. Repeat the process for the
other side. This completes cable installation.
4.2 CONNECTION TO THE RS-232 INTERFACE
9. Insert the strain relief assembly and wire into the slot in the
bottom half of the modem case and set it into the recess in the
case.
Once you have connected the twisted pair wires correctly, simply
plug the Model 1030 directly into the DB-25 port of the RS-232 device.
After doing so, remember to insert and tighten the two captive
connector screws.
4.2.1 CONNECTION TO A “DTE” DEVICE
The Model 1030 is wired as a DCE, and therefore wants to plug
into a DTE such as a terminal, PC or host. Because the Model 1030 is
interface powered, a direct connection to the RS-232 DTE port is most
desirable. If you must use a cable to connect the Model 1030 to the
DTE port, make sure it is a straight through cable of the shortest
possible length—we recommend 6 feet or less.
11
12
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX A
4.2.2 CONNECTION TO A “DCE” DEVICE
PATTON MODEL 1030/1030S SPECIFICATIONS
Since the Model 1030 is wired as a DCE, you cannot connect it
directly to another DCE such as a modem, multiplexer or printer. If you
need to connect the Model 1030 to another DCE device, you must use
a null modem cable wired according to diagram below. We recommend
that you use the shortest possible cable, preferably 6 feet or less.
Transmission Format:
Transmission Line:
Synchronous, full or half duplex
Two unconditioned twisted pair 19 - 26
AWG
Clocking:
Range:
Interfaces:
Data Rates:
Isolation:
Internal, external or receive loopback
(See table below)
EIA RS-232, CCITT V.24
1200 - 19.2 Kbps
Minimum 1500 V RMS via custom
transformers
Connection to Model 1030†
DB-25 Pin No.
Connection to DCE Device
DB-25 Pin No.
1....................................................1
Surge Protection:
Control Signals:
600W Surge Protection (10x1000µs
waveform) (Model 1030S only)
CTS turns on 8 or 53 mS (switch selectable)
after the terminal raises RTS; carrier
continuous or controlled by RTS; DCD turns
on immediately after recognizing the
received signal from the line
DB-25 male or female on RS-232 side; RJ-
11, RJ-45 or terminal block with strain relief
on line side
2....................................................3
3....................................................2
4....................................................8
8....................................................4
6..................................................20
20....................................................6
17..................................................24
24..................................................17
7....................................................7
Connectors:
Power Supply:
No external power required, uses power
from EIA data and control signals
0-60°C (32-140°F)
†Note: When connecting to another DCE device, the Model 1030
should be configured for “external clock” (see Section 3.2).
Temperature Range:
Altitude:
0-15,000 feet
Humidity:
Dimensions:
Weight:
5 to 95% noncondensing
2.66” x 2.10” x 0.73”
2 oz.
4.3 OPERATING THE MODEL 1030
Once the Model 1030 is properly configured and installed, it should
operate transparently—as if it were a standard cable connection.
Operating power is derived from the RS-232 data and control signals;
there is no “ON/OFF” switch. All data signals from the RS-232 interface
are passed straight through. In addition, one hardware control signal is
passed in either direction.
Model 1030 Distance Table (miles)
Wire Gauge
Data
Rate
19
7.5
10.0
10.0
10.0
11.0
24
3.5
3.5
7.0
8.5
8.5
26
2.5
2.5
4.0
5.0
6.0
19,200
9,600
4,800
2,400
1,200
13
14
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B
PATTON MODEL 1030/1030S
RS-232 PIN CONFIGURATIONS
DIRECTION
“DCE” STANDARD SETTING
DIRECTION
1- (FG) Frame Ground
2- (TD) Transmit Data
To Model 1030
From Model 1030
To Model 1030
From Model 1030
From Model 1030
Transmitting Timing - 15
3- (RD) Receive Data
4- (RTS) Request to Send
5- (CTS) Clear to Send
6- (DSR) Data Set Ready
7- (SG) Signal Ground
Receiver Timing - 17
From Model 1030
From Model 1030
To Model 1030
To Model 1030
Data Term. Ready (DTR) - 20
8- (DCD) Data Carrier Detect From Model 1030
Transmitting Timing LXC - 24
Copyright © 1998
Patton Electronics Company
All Rights Reserved
15