NON PENETRATING ROOF MOUNTS
PTX-NP400
PTX-NP550
PTX-NP658
Download from Www.Somanuals.com. All Manuals Search And Download.
PTX-NP400
SINGLE DUAL
TRIPLE
TRAY
QTY
TRAY
QTY
TRAY
QTY
ITEM #
PART #
DESCRIPTION
REV
8
4
4
4
0
1
1
0
16
4
4
4
8
1
0
1
1
2
3
4
5
6
7
8
295000
295001
295002
295003
295005
ASSY,NP TRAY ANGLE
BRKT,NP CORNER TIE
0
0
0
1
0
0
0
0
24
4
4
4
16
1
ASSY,NP FOOT
CHANNEL,NP LEG
BRKT,NP DUALCORNER TIE (UNBENT)
ASSY,NP400 PIPE
PREBAG,PTXNP400 HARDWARE SINGLE
PREBAG,PTXNP HARDWARE DUAL
295006
3HPPTXNP400
3HPPTXNP400DT
0
2
PTX-NP550
SINGLE DUAL
TRIPLE
TRAY
QTY
TRAY
QTY
TRAY
QTY
ITEM #
PART #
DESCRIPTION
REV
8
4
4
4
0
1
1
0
16
4
4
4
8
1
0
1
1
2
3
4
5
6
7
8
295000
295001
295002
295003
295005
ASSY,NP TRAY ANGLE
BRKT,NP CORNER TIE
0
0
0
1
0
0
0
0
24
4
4
4
16
1
ASSY,NP FOOT
CHANNEL,NP LEG
BRKT,NP DUALCORNER TIE (UNBENT)
ASSY,NP550 PIPE
PREBAG,PTXNP400 HARDWARE SINGLE
PREBAG,PTXNP HARDWARE DUAL
295004
3HPPTXNP400
3HPPTXNP400DT
0
2
PTX-NP658
DUAL
TRAY
QTY
ITEM #
PART #
DESCRIPTION
REV
16
4
4
4
8
1
0
1
1
2
3
4
5
6
7
8
295000
295001
295002
295003
295005
ASSY,NP TRAY ANGLE
BRKT,NP CORNER TIE
0
0
0
1
0
0
0
0
ASSY,NP FOOT
CHANNEL,NP LEG
BRKT,NP DUALCORNER TIE (UNBENT)
ASSY,NP658 PIPE
PREBAG,PTXNP400 HARDWARE SINGLE
PREBAG,PTXNP HARDWARE DUAL
295008
3HPPTXNP400
3HPPTXNP400DT
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SINGLE TRAY
ASSEMBLY
1) Lay out 8 NP TRAY ANGLE
ASSEMBLIES (prt# 295000)
4 NP CORNER TIE
BRACKETS (prt#295001)
and 4 NP FOOT ASSEMBLIES
(prt# 295002) as pictured to the
left.
NP Tray Angle
Assemblies
(prt# 295000)
2) Attach the NP CORNER TIE
BRACKET (prt# 295001)
as pictured to the left.
DO NOT tighten hardware at
this time.
NP Corner Tie
Bracket
(prt# 295001)
DETAIL A
SCALE 1 : 4
3/4”nc X 1-3/4”
Bolt, Washer, & Nut
Channel Leg
(prt# 295003)
3) Attach the CHANNEL LEG
(prt# 295003) to the NP
FOOT ASSEMBLY (prt#
295002) then the NP FOOT
ASSEMBLY to the NP
TRAY ANGLE ASSEMBLIES
(prt# 295000) as pictured.
DO NOT tighten hardware at
this time.
Foot Assembly
(prt# 295002)
3/4”nc X 2”
Bolt, Washer, & Nut
3/8”nc X 1-3/4”
Bolt, Washer, & Nut
DETAIL B
SCALE 1 : 4
4) Attach the CHANNEL LEG
(prt# 295003) to the PIPE
ASSEMBLY as pictured.
Tighten all hardware at
this time.
6
3/4”nc X 2”
Bolt, Washer, & Nut
Download from Www.Somanuals.com. All Manuals Search And Download.
DUAL TRAY
ASSEMBLY
1) Lay out 16 NP TRAY ANGLE
ASSEMBLIES (prt# 295000),
4 NP CORNER TIE BRACKETS
(prt#295001), 4 NP FOOT
ASSEMBLIES (prt# 295002) and
4 NP CORNER TIE BRACKET
UNBENT (prt#295005) as pictured
to the left.
NP Tray Angle
Assemblies
(prt# 295000)
2) Attach the NP CORNER TIE
BRACKET (prt# 295001)
and NP CORNER TIE
BRACKET-UNBENT
NP Corner Tie
Bracket Unbent
(prt# 295005)
(prt#295005) to the ANGLE
TRAY ANGLE ASSEMBLIES
as pictured to the left.
DO NOT tighten hardware at
this time.
DETAIL A
NP Corner Tie
Bracket
(prt# 295001)
SCALE 1 : 6
3/8”nc X 1-3/4”
Bolt, Washer, & Nut
Channel Leg
(prt# 295003)
3) Attach the CHANNEL LEG
(prt# 295003) to the NP
FOOT ASSEMBLY (prt#
295002) then the NP FOOT
ASSEMBLY to the NP
TRAY ANGLE ASSEMBLIES
(prt# 295000) as pictured.
DO NOT tighten hardware at
this time.
Foot Assembly
(prt# 295002)
3/4”nc X 2”
Bolt, Washer, & Nut
3/8”nc X 1-3/4”
Bolt, Washer, & Nut
DETAIL B
SCALE 1 : 6
4) Attach the CHANNEL LEG
(prt# 295003) to the PIPE
ASSEMBLY as pictured.
Tighten all hardware at
this time.
3/4”nc X 2”
Bolt, Washer, & Nut
7
Download from Www.Somanuals.com. All Manuals Search And Download.
TRIPLE TRAY
ASSEMBLY
1) Lay out 24 NP TRAY ANGLE
ASSEMBLIES (prt# 295000),
4 NP CORNER TIE BRACKETS
(prt#295001), 4 NP FOOT
ASSEMBLIES (prt# 295002) and
4 NP CORNER TIE BRACKET
UNBENT (prt#295005) as pictured
to the left.
NP Tray Angle
Assemblies
2) Attach the NP CORNER TIE
BRACKET (prt# 295001)
and NP CORNER TIE
BRACKET-UNBENT
(prt# 295000)
NP Corner Tie
Bracket Unbent
(prt# 295005)
(prt#295005) to the ANGLE
TRAY ANGLE ASSEMBLIES
as pictured to the left.
DO NOT tighten hardware at
this time.
NP Corner Tie
Bracket
(prt# 295001)
3/8”nc X 1-3/4”
Bolt, Washer, & Nut
DETAIL A
SCALE 1 : 10
Channel Leg
(prt# 295003)
3) Attach the CHANNEL LEG
(prt# 295003) to the NP
FOOT ASSEMBLY (prt#
295002) then the NP FOOT
ASSEMBLY to the NP
TRAY ANGLE ASSEMBLIES
(prt# 295000) as pictured.
DO NOT tighten hardware at
this time.
Foot Assembly
(prt# 295002)
3/4”nc X 2”
Bolt, Washer, & Nut
3/8”nc X 1-3/4”
Bolt, Washer, & Nut
DETAIL B
SCALE 1 : 6
4) Attach the CHANNEL LEG
(prt# 295003) to the PIPE
ASSEMBLY as pictured.
Tighten all hardware at
this time.
3/4”nc X 2”
Bolt, Washer, &
Nut
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Ballast Requirement Charts
1. Determine the Wind Speed requirement for the installation, and the Elevation Angle of the antenna.
2. Look up the required ballast for the antenna size being used.
3. Load the Base Trays with the required ballast using 4 x 8 x 16in solid cement blocks.
Elevation
(Degrees)
Elevation
(Degrees)
Ballast Required (lbs)at
Specific Wind Speed (mph)
Ballast Required (lbs)at
Specific Wind Speed (mph)
80 mph
634 lbs
494 lbs
285 lbs
80 mph
100 mph
1240 lbs 2435 lbs
100 mph
1370 lbs
1069 lbs
617 lbs
125 mph
2520 lbs
1966 lbs
125 mph
4303 lbs
22°
40°
60°
22°
40°
60°
967 lbs
558 lbs
1900 lbs 3356 lbs
1095 lbs
1134 lbs
1936 lbs
Elevation
Ballast Required (lbs)at
(Degrees)
Specific Wind Speed (mph)
80 mph
100 mph
4500 lbs
3510 lbs
2025 lbs
125 mph
7613 lbs
5939 lbs
3426 lbs
0°
20°
40°
2507 lbs
1956 lbs
1128 lbs
3Ballast
W
28 lb
Add-on Tray’s
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Grounding
Grounding Antenna Feed Cables
Coaxial
Cable
(to LNB)
1. Ground antenna feed cables in
accordance with current National
Electric code and local electric
codes. The illustration shows a
typical grounding method.
Clamps that provide a solid
connection between ground wire
and a ground source should be
used.
Ground Block
NEC Section 810
Ground Wire
NEC Section 810
Coaxial
Cable
(to Re-
ceiver)
Grounding Non-Penetrating
Mount Frame
1. Ground the Non-Penetrating
mount frame. The illustration
shows a typical grounding
method.
Ground Wire
Refer to the NEC Section 810
and local electric codes for
specific instructions on grounding
the remaining end of the ground
wire.
Non-Pen
Frame
1/4” Tapping
Bolt
External
Toothed
Washer
Ground
Lug
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Antenna Size
Pole Size
1.8m through 3.1m
4” & 5-1/2” OD
Powder Coated Steel
375 lbs
Materials
Mount weight (single tray)
Mount weight (double tray)
Mount weight (triple tray)
575lbs
775lbs
Ballast Load (single tray)
Ballast Load (double tray)
Ballast Load (triple tray)
2700 lbs
5500 lbs
7500 lbs
PATRIOT ANTENNA SYSTEMS
704 NORTH CLARK STREET
ALBION, MICHIGAN 49224 USA
WWW.SEPATRIOT.COM
2M95090 REV002
Download from Www.Somanuals.com. All Manuals Search And Download.
|