Panasonic Thermostat CZ 64ESMC1U User Manual

Operating Instructions  
System Controller  
Model No. CZ-64ESMC1U  
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.  
1006 Kadoma, Kadoma City, Osaka, Japan  
85464609159011  
CV6233189673  
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd  
1
2011/11/04 17:46:25  
INSTALLATION LOCATION  
• We recommend that this system controller be installed properly by qualified  
installation technicians in accordance with the Installation Instructions provided  
with the system controller.  
Do not install this system controller where there are fumes or flammable gases,  
or in an extremely humid space such as a greenhouse.  
Do not install the system controller where excessively high heatgenerating  
objects are placed.  
WARNING  
ELECTRICAL REQUIREMENTS  
1. All wiring must conform to the local electrical codes. Consult your dealer or a qualified  
electrician for details.  
2. Wiring must be done by a qualified electrician.  
To warm up the system, the power mains must be turned on at least five (5) hours  
before operation. Leave the power mains ON unless you will not be using this  
appliance for an extended period.  
CAUTION  
SAFETY INSTRUCTIONS  
• Read this Operating Instructions carefully before using this system controller. If you  
still have any difficulties or problems, consult your dealer for help.  
• The air conditioner is designed to give you comfortable room conditions. Use this only  
for its intended purpose as described in the Operating Instructions.  
Never touch the unit with wet hands.  
Never use or store gasoline or other flammable vapor or liquid near the air  
conditioner — it is very dangerous.  
The air conditioner has no ventilator for intaking fresh air from outdoors. You must  
open doors or windows frequently when you use gas or oil heating appliances in the  
same room, which consume a lot of oxygen from the air. Otherwise there is a risk of  
suffocation in an extreme case.  
WARNING  
CAUTION  
Do not turn the air conditioner on and off from the power mains switch. Use the ON/  
OFF operation button.  
Do not stick anything into the air outlet of the outdoor unit. This is dangerous  
because the fan is rotating at high speed.  
Do not let children play with the air conditioner.  
Do not cool or heat the room too much if babies or invalids are present.  
EN  
Note:  
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)  
This device may not cause harmful interference, and (2) this device must accept any interference received,  
including interference that may cause undesired operation.  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant  
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. This equipment generates, uses and can radiate radio frequency  
energy and, if not installed and used in accordance with the instructions, may cause harmful interference  
to radio communications. However, there is no guarantee that interference will not occur in a particular  
installation. If this equipment does cause harmful interference to radio or television reception, which  
can be determined by turning the equipment off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the equipment and receiver.  
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
• Consult the dealer or an experienced radio/TV technician for help.  
FCC Caution: To assure continued compliance, follow the attached installation instructions.  
Any changes or modifications not expressly approved by the party responsible for compliance could void  
the user’s authority to operate this equipment.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd  
3
2011/11/04 17:46:26  
HOW TO USE THE SYSTEM  
CONTROLLER  
Functions of buttons  
A: ALL/ZONE/GR  
SELECT button  
B: ZONE select C: GROUP select  
button button  
F: Operation  
lamp  
D: ON button  
E: OFF button  
G: MODE  
button  
H: Temperature  
setting  
buttons  
M: SET button  
K: CHECK  
button  
I: FAN SPEED button  
J: FLAP button  
O: VENTILATION  
button  
N: CL button  
CTRL  
L: CENTRAL  
button  
A: ALL/ZONE/GR SELECT button  
Use this button to select one of the following:  
ALL:  
Used for turning all the air conditioners on and off.  
ZONE: Used for turning all the air conditioners of each zone on and off.  
GROUP: Used for turning all the air conditioners of each group on and  
(GR)  
off.  
A maximum of four zones and 16 groups (units) in a zone can be set.  
NOTE  
B: ZONE select button  
Use this button to select a zone (1 to 4) to operate individually.  
C: GROUP select buttons  
Use these buttons to select a group (1 to 16) to operate individually.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd  
4
2011/11/04 17:46:26  
Functions of buttons (Continued)  
This button is for turning the selected air conditioner on.  
D: ON button  
E: OFF button  
F: Operation lamp  
This button is for turning the selected air conditioner off.  
This lamp lights when the unit is turned on.  
Use this button to select one of the following five operations:  
G: MODE button  
: Used to automatically set cooling or heating operation.  
Only for heat pump type  
(AUTO)  
(HEAT)  
(temperature range: 62 to 80 °F)  
: Used for normal heating operation.  
Only for heat pump type  
(temperature range: 60 to 78 °F)  
: Used for dehumidifying without changing the room temperature.  
(temperature range: 64 to 86 °F)  
(DRY)  
: Used for normal cooling operation.  
(COOL)  
(temperature range: 64 to 86 °F)  
: Used to run the fan only, without heating or cooling operation.  
(FAN)  
NOTE  
When the  
indication is displayed, you cannot change the mode from  
and or to or and . To change the mode, turn off all units once  
then select the mode again.  
H: Temperature setting  
buttons  
: Press this button to increase the temperature setting.  
: Press this button to decrease the temperature setting.  
I: FAN SPEED button  
(AUTO)  
(HI.)  
: The air conditioner automatically decides the fan speed.  
: High fan speed.  
(MED.)  
(LO.)  
: Medium fan speed.  
: Low fan speed.  
1. Use this button to set the airflow direction to a specific angle.  
The airflow direction is displayed on the remote controller.  
J: FLAP button  
Operation mode  
(COOL) or (DRY)  
(HEAT) or (FAN)  
(AUTO)  
Number of airflow direction settings  
3
5
EN  
Cooling mode:  
Heating mode:  
3
5
• In the cool mode and dry mode, when the flaps are set in a  
downward position, condensation may form and drip around the  
vent.  
• Do not move the flap with your hands.  
This function is available only for models U1 and T1.  
NOTE  
2. Use this button to make the airflow direction sweep up and down  
automatically.  
(
)
Press this button several times until the (  
display.  
) symbol appears on the  
This function is available only for models U1, K1 and T1.  
NOTE  
NOTE  
1) The flap setting can be performed only for units that have no remote  
controllers.  
2) In the ALL or ZONE mode, no flap setting can be performed. If  
necessary, you should select the GROUP mode and use the FLAP  
button.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd  
5
2011/11/04 17:46:26  
Functions of buttons (Continued)  
This button is used only when servicing the air conditioner.  
K: CHECK button  
Do not use the CHECK button for normal operation.  
Use this button to inhibit individual operation by remote controller as  
follows:  
L: CENTRAL  
button  
CTRL  
1: Individual ON/OFF operation is inhibited.  
2: Individual ON/OFF, MODE and Temperature setting operation is inhibited.  
3: Individual MODE and Temperature setting operation is inhibited.  
4: Individual MODE operation is inhibited.  
No indication: Central control is cleared. (Individual operation)  
This button is used for setting indoor unit's address when installing the air  
conditioner.  
M: SET button  
N: CL button  
NOTE  
Do not use the SET button for normal operation.  
Use this button to reset the filter sign  
.
The air conditioner has the timer for the filter and informs you when the  
filter needs cleaning.  
Use this button when you installed a fan available in the market.  
Pressing this button turns on and off the fan.  
O: VENTILATION button  
When turning off the air conditioner, the fan will also turned off. While  
the fan is operating,  
If is displayed when pressing the ventilation button, no fans are  
installed.  
will appear in the display.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd  
6
2011/11/04 17:46:27  
Display  
Description  
A: When the unit is in the heating standby mode, the  
B: The currently selected operation mode is displayed.  
indicator appears.  
C: The currently selected FAN SPEED, Airflow Direction and SWEEP settings are displayed.  
D: This indication appears when the filter needs cleaning.  
E: This indication appears only when an abnormality occurs within a unit.  
F: The currently selected mode (ALL, ZONE or GROUP), ZONE number and GROUP number are  
displayed.  
GROUP number display (no figure: no number registered)  
EN  
GROUP state display ( [ ] registered group,  
Operation state display ( on, no sign: off,  
currently selected group)  
alarm)  
G: The currently selected central control mode (1, 2, 3 or 4) is displayed.  
H: Lights when any of the air conditioners under the system control is operating; turns off when none of  
the air conditioners under the system control is operating. Blinks when any conditioner is operating  
under abnormal conditions and its protection functionality is working.  
I: When the  
button is pressed for more than four seconds, the TEST indicator appears.  
J: This indication appears when the temperature is set.  
K: When turning on the power switch of the system controller.  
sign blinks for a few minutes. While  
blinking, any controls using the system controller are inhibited. This is because the system controller  
is verifying connected groups.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd  
7
2011/11/04 17:46:27  
How to start group operation  
To start group operation  
Stop  
Power  
Turn the power supply switch on more than 5 hours before starting operation.  
Press the SELECT button and select GROUP.  
Select the ZONE No. including the group to be operated by pressing ZONE button.  
1
2
Select the GROUP No. to be operated by pressing GROUP select buttons  
Press the ON button.  
.
3
4
5
6
Set the operation mode by pressing the MODE button.  
Set the desired temperature by pressing one of the temperature setting buttons  
.
Set the desired fan speed by pressing the FAN SPEED button.  
Set the airflow direction to a specific angle or sweep mode.  
7
8
9
By pressing  
, select your desired setting.  
Individual: Controls with the remote controller are possible.  
Central 1: Individual ON/OFF operation with the remote controller is inhibited.  
Central 2: Individual ON/OFF, MODE, and Temp, setting operations with the remote  
controller are inhibited.  
Central 3: Individual MODE and Temp, setting operations with the remote controller are  
inhibited.  
Central 4: Individual MODE operation with the remote controller is inhibited.  
• Under Central/Individual settings other than listed above, “CENTRALis displayed.  
Confirming the GROUP No. to be selected, press the OFF button.  
Stop  
• The flap setting can be performed only for units that have no remote controllers.  
AUTO Depending on the difference between the temperature setting and  
NOTE  
Operation: the room temperature, heating and cooling alternate automatically so that a uniform  
room temperature is maintained.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd  
8
2011/11/04 17:46:27  
How to start collective operation  
To start collective operation (ALL or ZONE)  
Stop  
Power  
1
Turn the power supply switch on 5 hours or more before starting operation.  
Press the SELECT button and select ALL or ZONE.  
In case of ZONE collective operation.  
Select the ZONE No. to be operated by pressing ZONE button.  
Press the ON button.  
2
3
4
5
Set the operation mode by pressing the MODE button.  
Set the desired temperature by pressing one of the temperature setting buttons  
.
EN  
Set the desired fan speed by pressing the FAN SPEED button.  
Select the control mode.  
6
7
Confirming the ZONE No. to be selected or ALL indication, press the OFF button.  
Stop  
In the ALL or ZONE mode, no flap setting can be performed. If necessary, you should select the  
GROUP mode and use the FLAP button.  
NOTE  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd  
9
2011/11/04 17:46:28  
DC0911-11111  
Printed in Japan  
Download from Www.Somanuals.com. All Manuals Search And Download.  
01_CZ-64ESMC1U_EN.indd 10  
2011/11/04 17:46:28  

Moyer Diebel Dishwasher MH 60M2 User Manual
Multiquip Pet Fence mtr 40hs User Manual
Nesco Kitchen Utensil fs km User Manual
Nortel Networks Power Supply 8001PS User Manual
NuTone Outdoor Storage Vienna Series User Manual
Omron Healthcare Blood Pressure Monitor HEM 757 User Manual
Palsonic Car Video System TFTV 151 User Manual
Panasonic Computer Accessories CF VDD372 User Manual
Panasonic Network Card MAZC062D User Manual
Panasonic Printer KX MC6040CX User Manual