Panasonic Switch AJ8R User Manual

AJ8R  
J8 SWITCHES WITH  
TRIP FUNCTION  
POWER ROCKER SWITCH  
UPGRADED TYPE  
that shuts off the main power supply in  
response to a signal that is received from  
an external sensor.  
making it possible to achieve greater effi-  
ciency in wiring work.  
Receptacle for AMP's CT connector  
2. A dramatic upgrade in operation  
feelings  
These switches provide the same  
comfortable operation feelings our  
conventional J8 switches.  
• Comparison of feel when switch is  
turned on  
receptacle socket  
Conventional type  
Upgraded type  
4. Prolonged electrical service life.  
Coil operation provides an electrical life  
of at least 50,000 switching operations.  
5. Assures excellent ability to with-  
stand inrush current when used to  
turn a power supply on/off.  
FEATURES  
1. Power switches with an electromag-  
netic reset function which meet the  
need for energy savings in equipment  
and for safety.  
Applications for these switches include  
promoting energy savings in equipment  
(by reducing power consumption when  
OA equipment is in standby mode, for  
example), preventing fires caused by  
overheating of a heater inside equipment,  
preventing electrical leaks, and automati-  
cally turning off the power if the unit tips  
over or is shaken.These switches feature  
a built-in electromagnetic reset function  
The switch uses our own proprietary  
mechanism that provides an excellent  
ability to withstand inrush current is  
employed.  
Inrush current rating (IEC65) : 160A (nor-  
mally 16A at 125V AC), 10,000 times  
6. Approved under major international  
safety standards.  
Stroke  
3. CT terminals adopted for coil termi-  
nals  
These switches can be used with AMP's  
CT connectors, which are widely used for  
wiring connections in OA equipment,  
UL, cUL, TÜV and SEMKO approved.  
OPERATING PRINCIPLE  
• Manual operation is a repetition of (A) and (B) .  
This operation is independent of the electromagnetic reset function.  
• The reset mechanism operates only when an electromagnetic reset has occurred. (C)  
Contact  
ON  
OFF  
Manual operation  
(A)  
(B)  
Manual operation  
Iron core  
Manual opening/closing  
Return spring  
Permanent  
magnet  
(C)  
Flips actuator  
Electromagnetic reset  
Coil  
Coil terminal  
Electromagnetic reset mechanism  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
03/2005  
AJ8R  
SPECIFICATIONS  
1. Contact rating  
Motor load  
(EN61058-1)  
(pf = 0.6)  
Resistive load  
(pf = 1)  
Voltage  
Inrush load  
125V AC  
125V AC  
16A  
10A  
160A (8.3ms)  
4A  
Remark: The motor load is in accordance with EN61058-1. Inrush current can be switched up to the value of 6 times the indicated rating.  
2. Coil rating  
Nominal Voltage  
*(Max. 10 sec)  
Drop-out voltage  
(at 20°C 68° F)  
Nominal operating current  
[±10%] (at 20°C 68° F)  
Coil resistance  
[±10%] (at 20°C 68° F)  
Maximum voltage  
(Max. 1 sec)  
Max.4.5V  
Min.0.5V  
5V DC  
12V DC  
24V DC  
725mA  
300mA  
150mA  
6.9Ω  
40Ω  
5.5V  
Max.10.8V  
Min.1.2V  
13.2V  
26.4V  
Max.21.6V  
Min.2.4V  
160Ω  
Remark: If the rated voltage is applied to the coil for more than ten seconds or the maximum voltage is applied for more than one second, coil perfor-  
mance will deteriorate.  
3. Characteristics  
Min.104  
(at 7 cpm.,at rated load)  
Manual operation  
Electrical life  
Min.103  
Coil operation  
(at 7 cpm.,at rated load)  
Min.5×104(at 7 cpm. 5A 125V AC resistive load)  
Mechanical life  
Min.5×104(at 20 cpm.)  
Initial contact resistance  
(By voltage drop at 1A, 2 to 4V DC)  
Max. 100mΩ  
Initial insulation resistance  
Min. 100m(at 500V DC measured by insulation resistive meter)  
Between contacts  
2,000 Vrms  
4,000 Vrms  
Initial breakdown voltage  
Ambient temperature  
Between coil and contact  
0°C to +60°C  
32° F to +140° F  
(Not freezing below 0°C 32° F)  
Ambient humidity  
Max. 85% R.H.  
Vibration resistance  
10 to 55 Hz at single amplitude of 0.75mm  
Min.294m/s2{30G}  
Functional  
Destructive  
(Contact opening Max. 1ms)  
Shock resistance  
Min.980m/s2{100G}  
.250 Quick-connect terminal Min. 98N{10kgf}/min.  
(Pull & push direction)  
Tensile terminal strength  
Actuator strength  
39.2N{4kgf} for 1min. operating direction  
Max. 100ms (at rated voltage)  
Contact release time  
Initial operating force  
* Reference value  
4.9N or less (Max. 500gf or less)  
Setting force after reset has been released: Max. 6.86N or less (Max. 700gf or less)  
Flame retardancy  
Tracking resistance  
UL94V-0  
Min. 175  
Single pole, single throw: Approx. 17g .60oz  
Single pole, double throw: Approx. 19g .67oz  
Double pole, single throw: Approx. 20g .71oz  
Unit weight  
Remark: Test conditions are in accordance with EN61058-1,UL1054 and JIS C 6571  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
03/2005  
AJ8R  
DIMENSIONS  
Double pole (ON-OFF)  
Wiring diagram(Bottom view)  
Single pole (ON-OFF)  
ON (set): 1-2  
25  
Single pole (ON-ON)  
.984  
22+0  
0.2  
.866+0  
.008  
32  
1.260  
19.7  
.776  
8.6  
.339  
Reset: 1-4 closed  
Set: 1-2 closed  
2
.079  
16  
.630  
Double pole (ON-OFF)  
φ1.75  
φ.069  
10.6  
.417  
13.5  
.531  
0.8  
.031  
ON (set): 1-2 closed  
3-4 closed  
6.35  
.250  
(11.3)  
(.445)  
4.4  
.173  
15  
18.3  
.591  
.720  
29.8±0.3  
21.7±0.25  
.854±.010  
1.173±.012  
Diagram of recommended locations for  
panel mounting holes  
Suitable connector: CT connector  
R Max. 01  
X
Opening radius  
Y
Edge  
Panel thickness  
X
Y
1 to less than 1.8  
.039 to .071  
30.4 +0  
–0.1  
+0  
22.0+0.1  
–0  
+.004  
1.197  
.866  
–.004  
–0  
1.8 to 2.3  
.071 to .091  
31.1 +0  
–0.1  
22.0+0.1  
–0  
+0  
+.004  
1.224  
.866  
–.004  
–0  
The opening radius from when  
the panel was processed should  
be on the front side of the panel  
Remark: Contact us if you are considering  
using a panel of other than the rec-  
ommended size and shape.  
Remarks: 1. The external dimensions and mounting dimensions for the single pole, single throw  
type and the single pole, double throw type are the same as those for the double pole,  
single throw type indicated above.  
2. The figures show the double pole, single throw (ON-OFF) type as an example.  
The contact terminals are 1, 2, 3, and 4.  
In the case of the single pole, single throw (ON-OFF) type, the contact terminals are 1  
and 2.  
In the case of the single pole, double throw (ON-ON) type, the contact terminals are  
1, 2, and 4.  
There are no other terminals.  
Refer to the internal wiring diagram.  
3. The coil is a polarized coil; coil terminal 5 is positive and coil terminal 6 is negative.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
03/2005  
AJ8R  
NOTES  
1. Operating voltage application time  
If the rated voltage is applied to the coil  
for more than 10 seconds or the maxi-  
mum voltage is applied for more than 1  
second, coil performance may deterio-  
rate.  
(3) Use a receptacle that is compliant  
with JIS C 2809.  
10.This product is not hermetically  
sealed, so its performance could dete-  
riorate under certain ambient condi-  
tions. Avoid using and storing these  
switches in a location where they will  
be exposed to corrosive gases, sili-  
con, or high dust levels, all of which  
can have an adverse effect on the con-  
tacts. In addition, because these  
switches contain permanent magnets,  
avoid using and storing these  
In addition, there is some deviation  
regarding the insertion force depending  
on the model used from different manu-  
facturers, so the insertion force should be  
checked under realistic conditions.  
(4) Use AMP's CT connector for the coil  
terminals.  
6. Because special receptacle termi-  
nals are used for the contact terminals  
and the common terminals, do not  
attempt to solder them. Doing so  
could melt plastic components and  
otherwise harm the performance of  
the switch  
7.The terminals should be connected  
in such a way that they are not under  
constant stress from the connecting  
wires.  
8.Take care not to drop the product as  
it may impair performance.  
2.The shape of the mounting panel  
should be as recommended in the  
dimensions diagram.  
Contact us if you are considering using a  
panel of other than the recommended  
size and shape.  
3.The mounting panel should be made  
of SPCC. If a different material is used,  
its adhesion to the switch unit may be  
not be as strong. Check this on site if  
necessary.  
4. Note that the actuator could pop out  
of the switch housing if 19.6N (2kgf) or  
more of force is applied to the side of  
the actuator.  
switches in a location where metallic  
dust, etc., is present.  
11.When these switches are used with  
weak currents of 500mA or less, a  
layer of material on the surface of the  
contacts may cause contact instabil-  
ity. Check and evaluate this possibility  
before using these switches under  
such conditions.  
12. When using an ON-OFF type  
switch with no (|O) indication on the  
actuator, the "OFF" position should be  
indicated on the set in which the  
switch is installed.  
5.  
(1) When connecting the tab terminals,  
use a .250 receptacle and insert the ter-  
minals straight in.  
9. Resistance to chemicals  
To clean the switch unit, use a neutral  
detergent diluted with water.  
If you insert them at an angle, the termi-  
nals could catch on the opening and will  
require greater insertion force.  
(2) The coil terminals have specific polar-  
ities. Make sure you connect them cor-  
rectly.  
Do not use acidic or alkaline solvents as  
they may damage the switch.  
Furthermore, be careful not to get any of  
the detergent solution inside of the switch  
while cleaning it.  
13.To assure reliability, check the  
switch under actual loading condi-  
tions. Avoid any situation that may  
adversely affect switching perfor-  
mance.  
COIL TERMINAL CONNECTOR  
Because CT terminals are used for the  
coil terminals, AMP's CT connector can  
be used.  
AMP's CT connector  
Remark: We do not sell this type of connector.  
Questions concerning this connector  
should be directed to the manufac-  
turer.  
receptacle socket  
Pressure welding type:  
173977-2: for AWG26, 28  
2-179694-2: for AWG24  
Crimping type:  
179228-2  
12/1/2002  
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
03/2005  

Minolta Digital Camera Maxxum 3000i User Manual
Mountfield Lawn Mower MP84401 05 User Manual
Multi Tech Systems Scanner FF110 User Manual
NordicTrack Home Gym NTL17941 User Manual
Northern Industrial Tools Air Compressor 123006 User Manual
Optoma Technology Projection Television HDBV3100 User Manual
P3 International Portable Radio E 9300 User Manual
Panasonic Air Conditioner CS E12NKUAW User Manual
Panasonic Flat Panel Television 1080p User Manual
Panasonic Security Camera AW E800 User Manual