Panasonic Smoke Alarm EQ 500 Series User Manual

SERIES  
EQ-500  
Multi-voltage Amplifier Built-in  
ADJUSTABLE RANGE REFLECTIVE  
PHOTOELECTRIC SENSOR  
Long sensing range 2.5 m  
Multi-voltage  
Not affected by background objects  
EQ50  
Because it can function with 24 to 240 V AC and 12 to 240 V  
DC, almost any power supply anywhere in the world will do.  
Because the sensor doesn’t detect objects outside the preset  
sensing field by using the 2-segment photodiode adjustable  
range system, it will not malfunction even if someone walks  
behind the sensing object or machines or conveyors are in  
the background.  
EQ51Ⅺ  
Impervious to variations color or angle  
Introducing the new DC-voltage type  
equipped with BGS / FGS function  
Due to its advanced optical system, the sensor is not affected  
by variations in the object’s angle or gloss compared to  
conventional sensors.  
Moreover, as the difference in sensing range between black  
and white varies by only approx. 5 % (Note), sensing can be  
performed at a somewhat constant distance even if the  
sensing object is black or white.  
We’ve added a DC-voltage type with NPN and PNP  
transistor outputs all in one sensor. Its BGS / FGS function  
controls any background effects for more stable sensing.  
Refer to p.196 for the BGS / FGS functions.  
Note: Example of the difference in sensing range between  
black non-glossy paper (Lightness: 5) and white non-  
glossy paper when the setting distance is set at 2 m  
6.562 ft.  
194  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  
EQ-500  
BGS / FGS FUNCTIONS MAKE EVEN THE MOST CHALLENGING SETTINGS POSSIBLE!  
The BGS function is best suited for the following case  
Background not present  
BGS (Background suppression) function  
When object and background are  
separated  
The sensor judges that an object is present when light is received at position A of  
the light-receiving element (2-segment element). This is useful if the object and  
background are far apart. Not affected if the background color changes or  
someone passes behind the conveyor.  
OFF  
Light received at element  
B or light not received  
ON  
Light received at  
element A  
Element A  
Element B  
Moving object  
in the back  
Object  
Setting distance  
The FGS function is best suited for the following case  
Background present  
FGS (Foreground suppression) function  
When object and background are close  
together  
When the object is glossy or uneven  
The sensor judges that no object is present when light is received at position B of  
the light receiving element (2-segment element)(The conveyor is detected). This  
function is useful if the object and the background are close together or if the  
object is glossy or uneven. However, sensing is impossible if there is no  
background (conveyor, etc.)..  
OFF in this condition only  
Object absent  
ON in all other conditions  
For glossy  
object  
ON  
Object present  
ON  
OFF  
Element A  
Emitting  
element  
Element B  
Lens  
Setting  
distance  
Conveyor  
Conveyor  
Conveyor  
Light received at element B  
A conveyor or other  
Light received  
at element A  
Light is not received at  
element B, so an object  
is judged to be present  
background must be present.  
196  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  
EQ-500  
OPTIONS  
Type  
Appearance  
Sensing range  
Model No.  
Supply voltage  
Output  
Timer function  
EQ-501  
EQ-501T  
EQ-502  
EQ-502T  
EQ-511  
0.1 to 2.5 m  
0.328 to 8.202 ft  
24 to 240 V AC  
ע
10 %  
ON-delay / OFF-delay timer  
(Timer period: 0.1 to 5 sec.)  
W
or  
Relay contact 1a  
12 to 240 V DC  
ע
10 %  
M
0.1 to 1.0 m  
0.328 to 3.281 ft  
ON-delay / OFF-delay timer  
(Timer period: 0.1 to 5 sec.)  
W
0.1 to 2.5 m  
0.328 to 8.202 ft  
NPN open-collector  
transistor  
PNP open-collector  
transistor  
ON-delay / OFF-delay timer  
(Timer period: 0.1 to 5 sec.)  
EQ-511T  
EQ-512  
EQ-512T  
12 to 24 V DC  
ע
10 %  
Equipped with  
2 outputs  
(
)
0.1 to 1.0 m  
0.328 to 3.281 ft  
ON-delay / OFF-delay timer  
(Timer period: 0.1 to 5 sec.)  
OPTION  
Sensor mounting bracket  
Designation  
Sensor mounting bracket  
Model No.  
Description  
Foot / back angled mounting bracket  
MS-EQ5-01  
Two M5 (length 30 mm 1.181 in)  
screws with washers and two  
nuts are attached.  
MS-EQ5-01  
197  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  
EQ-500  
SPECIFICATIONS  
Multi-voltage  
With timer  
EQ-501T  
DC-voltage  
With timer  
EQ-511T  
Type  
With timer  
With timer  
Item  
Model No.  
EQ-501  
EQ-502  
EQ-502T  
EQ-511  
EQ-512  
EQ-512T  
Adjustable range (Note 1) (Note 2) 0.2 to 2.5 m 0.656 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft 0.2 to 2.5 m 0.656 to 8.202 ft 0.2 to 1.0 m 0.656 to 3.281 ft  
Sensing range (at maximum setting distance) (Note 2)  
0.1 to 2.5 m 0.328 to 8.202 ft 0.1 to 1.0 m 0.328 to 3.281 ft 0.1 to 2.5 m 0.328 to 8.202 ft 0.1 to 1.0 m 0.328 to 3.281 ft  
10 % or less of operation distance  
Hysteresis  
24 to 240 V AC 
ע
10 % or 12 to 240 V DC 
ע
10 %  
12 to 24 V DC
ע
10 % Ripple P-P 10 % or less  
Ripple P-P 10 % or less  
Supply voltage  
AC: 4 VA or less AC: 5 VA or less AC: 4 VA or less AC: 5 VA or less  
45 mA or less  
Power / Current consumption  
DC: 3 W or less DC: 4 W or less DC: 3 W or less DC: 4 W or less  
NPN open-collector transistor  
Maximum sink current: 100 mA  
Applied voltage: 30 V DC or less (between output and 0 V)  
Residual voltage: 1 V or less (at 100 mA sink current)  
Relay contact 1a  
Switching capacity: 250 V AC 3 A (resistive load)  
30 V DC 3 A (resistive load)  
0.4 V or less (at 16 mA sink current)  
Output  
Electrical life: 100,000 or more switching operations  
(switching frequency 1,200 operations/hour)  
Mechanical life: 50 million or more switching operations  
PNP open-collector transistor  
Maximum source current: 100 mA  
Applied voltage: 30 V DC or less (between output and 
ם
V)  
Residual voltage: 1 V or less (at 100 mA source current)  
(switching frequency 18,000 operations/hour)  
0.4 V or less (at 16 mA source current)  
Output operation  
Short-circuit protection  
Response time  
Switchable either Detection-ON or Detection-OFF  
Incorporated  
20 ms or less (For EQ-50T depends on the setting timer period) 2 ms or less (For EQ-51T depends on the setting timer period)  
Orange LED (lights up when the output is ON)  
Operation indicator  
Stability indicator  
Distance adjuster  
Sensing mode  
Green LED (lights up under stable operating condition)  
2-turn mechanical adjuster with indicator  
Switchable either BGS or FGS function  
Incorporated  
with variable  
(0.1 to 5 sec.)  
ON-delay /  
Incorporated  
with variable  
(0.1 to 5 sec.)  
ON-delay /  
Incorporated  
with variable  
(0.1 to 5 sec.)  
ON-delay /  
Incorporated  
with variable  
(0.1 to 5 sec.)  
ON-delay /  
Timer function  
OFF-delay timer  
OFF-delay timer  
OFF-delay timer  
OFF-delay timer  
Automatic interference prevention function  
Protection  
Incorporated (Note 3)  
IP67 (IEC)  
Ambient temperature  
Ambient humidity  
Ambient illuminance  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
Emitting element  
Receiving element  
Material  
מ
20 to 55 ЊC 
מ
4 to
ם
131 ЊF (No dew condensation or icing allowed), Storage: 
מ
30 to
ם
70 ЊC 
מ
22 to
ם
158 ЊF  
35 to 85 % RH, Storage: 35 to 85 % RH  
Sunlight: 10,000 ?x at the light-receiving face, Incandescent light: 3,000 ?x at the light-receiving face  
2,000 V AC for one min. among supply terminals, non-supply metal parts and relay contact output terminals, 1,000 V AC for one min. between relay contacts  
100 M , or more, with 500 V DC megger among supply terminals, non-supply metal parts and relay contact output terminals as well as between relay contacts  
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each  
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each  
Infrared LED (modulated)  
2-segment photodiode  
Enclosure: ABS, Front cover: Polycarbonate, Display cover: Polycarbonate  
Screw-on terminal connection  
Connection method  
Cable  
Suitable for round cable "9 to"11 mm "0.354 to "0.433 in  
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cabtyre cable  
Cable length  
Weight  
100 g approx.  
85 g approx.  
Accessory  
Adjusting screwdriver: 1 pc.  
Notes: 1) The adjustable range stands for the maximum sensing range which can be set with the distance adjuster. The sensor can also detect an object 0.1 m  
0.328 ft, or more, away.  
2) The adjustable range and the sensing range are specified for white non-glossy paper (200
ן
200 mm 7.874
ן
7.874 in) as the object.  
3) Note that the detection may be unstable depending on the mounting conditions or the sensing object. In the state that this product is mounted, be sure  
to check the operation with the actual sensing object. Refer to ‘Automatic interference function’ (p.8) of ‘PRECAUTIONS FOR PROPER USE’ for  
details.  
198  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  
EQ-500  
I/O CIRCUIT AND WIRING DIAGRAMS  
EQ-501(T)  
EQ-502(T)  
I/O circuit diagram  
Terminal arrangement diagram  
Terminal No.  
1
2
Supply voltage  
24 to 240 V AC
ע
10 %  
or  
Multi-voltage  
circuit  
2
4
1
3
12 to 240 V DC
ע
10 %  
Output relay  
S
3
4
Relay contact output  
(1a)  
Internal circuit  
EQ-511(T)  
EQ-512(T)  
I/O circuit diagram  
Terminal arrangement diagram  
Terminal No.  
D
ם
V  
1
4
3
2
ZD2  
Tr2  
Tr1  
100 mA max.  
2
4
1
3
Load  
ם
מ
Output (PNP)  
Load  
12 to 24 V DC  
ע
10 %  
Output (NPN)  
100 mA max.  
ZD1  
0 V  
Internal circuit  
Users’ circuit  
Symbols... D : Reverse supply polarity protection diode  
ZD1, ZD2: Surge absorption zener diode  
Tr1: NPN output transistor  
Tr2: PNP output transistor  
SENSING CHARACTERISTICS (TYPICAL)  
EQ-501(T)  
EQ-511(T)  
Sensing fields  
Correlation between material  
Setting distance: 1 m 3.281 ft  
Setting distance: 2.5 m 8.202 ft  
(200
؂
200 mm 7.874
؂
7.874 in) and sensing range  
4
13.123  
White non-  
glossy paper  
Black non-glossy paper  
Lightness: 5  
White non-  
glossy paper  
Black non-glossy paper  
Lightness: 5  
2.5  
8.202  
1
3.281  
3
9.843  
200
ן
200 mm  
2
6.562  
7.874
ן
7.874 in  
These bars indicate the  
0.5  
Non-glossy paper  
200
ן
200 mm  
7.874
ן
7.874 in  
Non-glossy paper  
sensing range with the  
respective objects when  
the distance adjuster is set  
to a sensing range of 2.5 m  
8.202 ft / 1 m 3.281 ft long,  
respectively, with white  
non-glossy paper.  
1.640  
2.5 m  
1
⅐⅐⅐  
⅐⅐⅐  
8.202 ft  
#
3.281  
L
#
L
1
3.281  
1 m  
3.281 ft  
Sensor  
Sensor  
0
0
0
20  
10  
0
10  
20  
0.787  
20  
10  
0.394  
Left  
0
10  
20  
0.787  
0.787  
0.394  
0.394  
Right  
0.787  
0.394  
Left  
Center  
Center  
Right  
Operating point ?(mm in)  
Operating point ?(mm in)  
Emitted beam  
Correlation between color  
Correlation between sensing object size  
and sensing range  
(200  
؂
200 mm 7.874
؂
7.874 in non-glossy paper) and sensing range  
These bars indicate the  
sensing range with the re-  
spective colors when the  
distance adjuster is set to a  
Setting distance: 2.5 m 8.202 ft  
"70 mm  
2.5  
"2.756 in  
2.5  
2.5  
8.202  
8.202  
8.202  
sensing range of 2.5  
m
"56 mm  
"2.205 in  
8.202 ft / 1 m 3.281 ft long,  
respectively, with white non-  
glossy paper.  
The sensing range also  
varies depending on material.  
2
6.562  
2
6.562  
This curve shows  
the characteristics  
with the maximum  
sensing range set  
to 2.5 m 8.202 ft,  
with white non-  
glossy paper  
"42 mm  
1.5  
4.921  
"1.654 in  
White non-  
glossy paper  
"26 mm  
"1.024 in  
1
3.281  
L
1
3.281  
1
3.281  
2.5 m  
⅐⅐⅐  
8.202 ft  
"20mm  
"0.787 in  
0.5  
1.640  
1 m  
⅐⅐⅐  
3.281 ft  
(200  
7.874  
200  
7.874  
ן
200 mm  
7.874 in).  
Sensor  
100  
0
ן
0
0
50  
1.969  
150  
5.906  
3.937  
White non-glossy paper  
side length a (mm in)  
199  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  
EQ-500  
SENSING CHARACTERISTICS (TYPICAL)  
EQ-502(T)  
EQ-512(T)  
Sensing fields  
Correlation between material  
Setting distance: 0.5 m 1.640 ft  
(200
؂
200 mm 7.874
؂
7.874 in) and sensing range  
Setting distance: 1 m 3.281 ft  
0.8  
2.625  
White non-  
glossy paper  
White non-  
glossy paper  
Black non-glossy paper  
Black non-glossy paper  
Lightness: 5  
Lightness: 5  
1
3.281  
)
)
1
3.281  
)
f
f
0.6  
1.969  
f
200  
7.874  
Non-glossy paper  
ן
200 mm  
200  
7.874  
Non-glossy paper  
ן
200 mm  
These bars indicate the  
sensing range with the  
respective objects when  
the distance adjuster is set  
to a sensing range of 1 m  
3.281 ft / 0.5 m 1.640 ft  
long, respectively, with  
white non-glossy paper.  
0.4  
ן
7.874 in  
ן
7.874 in  
1.312  
0.5  
0.5  
1.640  
1 m  
1.640  
⅐⅐⅐  
⅐⅐⅐  
3.281 ft  
L
L
?
?
0.2  
0.656  
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               e
S
S
0.5 m  
1.640 ft  
Sensor  
Sensor  
0
0
0
20  
10  
0
10  
0.394  
20  
0.787  
20  
10  
0.394  
Left  
Operating point ?(mm in)  
0
10  
20  
0.787  
0.787  
0.394  
0.787  
0.394  
Left  
Center  
Right  
Center  
Right  
Operating point ?(mm in)  
Correlation between color  
Emitted beam  
Correlation between sensing object size  
and sensing range  
(200  
؂
200 mm 7.874
؂
7.874 in non-glossy paper) and sensing range  
These bars indicate the  
sensing range with the re-  
spective colors when the  
distance adjuster is set to a  
sensing range of 1 m 3.281 ft  
Setting distance: 1 m 3.281 ft  
"26 mm  
1
1
1
"1.024 in  
3.281  
3.281  
3.281  
/
0.5  
m
1.640 ft long,  
This curve shows  
respectively, with white non-  
glossy paper.  
The sensing range also  
varies depending on material.  
the characteristics  
with the maximum  
sensing range set  
"20 mm  
"0.787 in  
0.5  
1.640  
0.5  
1.640  
0.5  
1.640  
White non-  
L
glossy paper  
to  
1
m
3.281 ft,  
1 m  
⅐⅐⅐  
with white non-  
glossy paper  
3.281 ft  
0.5 m  
⅐⅐⅐  
(200  
7.874  
ן
200 mm  
7.874 in).  
1.640 ft  
Sensor  
ן
0
0
50  
1.969  
100  
3.937  
150  
5.906  
200  
7.874  
White non-glossy paper  
side length a (mm in)  
PRECAUTIONS FOR PROPER USE  
When a specular body is present below the sensor, use the  
sensor by tilting it slightly upwards to avoid faulty operation.  
This product is not a safety sensor. Its use is not  
intended or designed to protect life and prevent body  
injury or property damage from dangerous parts of  
machinery. It is a normal object detection sensor.  
<Incorrect>  
<Correct>  
Specular  
face  
Specular  
face  
M5 nut  
Mounting  
M5 (length 30 mm 1.181 in)  
screw with washers  
The tightening torque  
should be 0.8 Nm or  
less.  
Tilt  
Sensor  
mounting  
blacket  
MS-EQ5-01  
(Optional)  
This product is not easily affected by the reflected light intensity  
since this sensor is the adjustable range reflective type. When  
the reflected light intensity is remarkably low, the sensing range  
may be affected. In that case, mount the sensor, while checking  
light-up of the stable indicator (green).  
Care must be taken regarding the sensor mounting direction with  
respect to the object’s direction of movement.  
The mounting screws of the terminal cover and display cover  
should certainly be tightened to maintain water-resistance; the  
tightening torque of the screws should be 0.3 to 0.5 Nm.  
<Correct>  
<Correct>  
<Incorrect>  
Automatic interference prevention function  
When the sensors are mounted closely, use them in the  
interference prevented area, as shown below.  
9.8343  
6.5262  
3.2181  
3
9.843  
Do not make the sensor  
L mm in  
or more  
detect an object in this  
direction because it may  
2
Sensing object  
6.562  
Sensing object  
Sensing object  
cause  
unstable  
3.2181  
0
Interference  
Interference  
prevented area  
When detecting a specular object (aluminum or copper foil, etc.)  
or an object having a glossy surface or coating, please note that  
there are cases when the object may not be detected due to a  
change in angle, wrinkles on the object surface, etc.  
prevented area  
L mm in  
or more  
L mm in  
or more  
L mm in  
or more  
0
02.7087 14.5075 26.3062 80  
3.15  
Mounting interval L (mm in)  
50 100 150 200 250  
1.969 3.937 5.906 7.874 9.843  
Mounting interval L (mm in)  
If a specular body is present in the background, faulty operation  
may be caused due to a small change in the angle of the  
background body. In that case, install the sensor at an inclination  
and confirm the operation with the actual sensing object.  
Note that the detection may be unstable depending on the  
mounting conditions or the sensing object to be used.  
In the state that this product is mounted, be sure to check the  
operation with the actual sensing object to be used.  
200  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  
EQ-500  
PRECAUTIONS FOR PROPER USE  
Wiring  
Part description  
Make sure that the power supply is off while wiring.  
Stability indicator (Green)  
Check all wiring before applying power since incorrect wiring may  
damage the internal circuit. Also, carefully tighten the terminal  
screws so that the wires of adjacent terminals do not touch.  
Distance adjuster (2-turn)  
OFF-delay timer adjuster (Note 2)  
The mounting hole for the terminal cover fixing screws inclines  
70 degrees to the terminal cover, as shown in the figure below.  
To avoid damaging this product or screw, take care when  
tightening or loosening a screw.  
Adjuster indicator  
ON-delay timer adjuster (Note 2)  
Operation mode switch (Note 1)  
Operation indicator (Orange)  
Screw for terminal cover fixing  
Notes: 1) The operation mode switch of the DC-voltage type is the DIP  
switch. Refer to ‘DC-voltage type’ of ‘Operation mode switch’  
for details.  
2) Incorporated on EQ-5T only.  
Screwdriver  
Operation mode switch  
Multi-voltage type (L-ON / D-ON mode only)  
To maintain water-resistance, the cable should have an outer  
diameter between "9 to "11 mm "0.354 to "0.433 in with a  
smooth covering material that allows the attached conduit  
connector to be securely tightened; the tightening torque of the  
screw should be of 1.5 to 2.0 Nm.  
Operation mode switch  
Description  
Verify that the supply voltage variation is within the rating.  
Detection-ON mode is obtained when the switch  
is turned fully clockwise (L side).  
If power is supplied from a commercial switching regulator,  
ensure that the frame ground (F.G.) terminal of the power supply  
is connected to an actual ground.  
Detection-OFF mode is obtained when the switch  
is turned fully counterclockwise (D side).  
In case noise generating equipment (switching regulator, inverter  
motor, etc.) is used in the vicinity of this sensor, connect the  
frame ground (F.G.) terminal of the equipment to an actual ground.  
Note: Turn the operation mode switch gradually and lightly with the attached  
screwdriver. Turning with excessive strength will cause damage to the  
adjuster.  
Do not run the wires together with high-voltage lines or power  
lines or put them in the same raceway. This can cause  
malfunction due to induction.  
If an external surge voltage exceeding 4 kV is impressed (DC-  
voltage type: 1 kV), the internal circuit will be damaged, and a  
surge suppressing element should be used.  
DC-voltage type  
L-ON / D-ON mode  
BGS / FGS mode  
Timer mode  
L
BGS  
OFF  
N.C.  
D
Prepare the cable end as shown below.  
FGS  
Timer ON  
N.C.  
Conduit connector construction and cabling  
Not used  
37 mm  
1.457 in  
Power supply  
BGS / FGS function (DC-voltage type only)  
Conduit connector  
DC-voltage type sensor incorporates BGS / FGS function. Select  
either the BGS or FGS function depending on the positions of the  
background and sensing object.  
BGS / FGS function is set with the operation mode switch.  
Depends on a selection of either BGS or FGS function, the out-  
put operation changes as follows.  
Output  
25 mm  
0.984 in  
Gland packing (Note)  
Gland  
Note: When assembling the conduit connector, pay attention to the direction  
of the gland packing.  
Furthermore, in order to maintain water-resistance, fit the gland  
packing such that the seating surface of the gland packing contacts  
the packing holder part of the terminal cover evenly.  
Detectable range  
The size of conduit is M20
ן
1.5.  
If pressure terminals are to be used, affix the connected  
Setting distance  
pressure terminals to a terminal (M3.5 screw).  
Non-detectable area  
Dimensions of the suitable crimp terminals  
ON  
(Unit: mm in)  
L-ON  
OFF  
BGS  
Round type  
Y-shaped type  
ON  
D-ON  
OFF  
"3.6  
22 0.866  
22 0.866  
"0.142  
3.6 0.142  
or more  
ON  
or less  
or less  
L-ON  
or more  
10 0.394  
or less  
10 0.394  
or less  
OFF  
FGS  
ON  
7.5 0.295  
or less  
7 0.276  
or less  
7.5 0.295  
or less  
7 0.276  
or less  
D-ON  
OFF  
17 0.669  
or less  
(After crimping)  
17 0.669  
or less  
(After crimping)  
Note: Use crimp terminals with insulating sleeves.  
Recommended crimp terminal: Nominal size 1.25
ן
3.5 0.049
ן
0.138.  
The tightening torque for the terminal screws should be 0.3 to 0.5 Nm.  
201  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  
EQ-500  
PRECAUTIONS FOR PROPER USE  
Distance adjustment  
Timer function (EQ-5T only)  
EQ-5T incorporates an OFF-delay timer, which is useful when  
the response of the connected device is slow, etc., and an  
ON-delay timer, which is useful for detecting objects that move  
slowly, for example.  
For DC-voltage type, be sure to set the BGS / FGS function before  
distance adjustment. If the setting is done after the distance ad-  
justment, the sensing area is changed.  
The OFF-delay and ON-delay timers can be used simultaneously.  
For DC-voltage type, set the DIP switch for the timer mode to  
‘Timer ON’ side.  
Turn the distance adjuster gradually and lightly with the attached  
adjusting screwdriver. Turning with excessive strength will cause  
damage to the adjuster.  
Multi-voltage type, DC-voltage type BGS select  
Time chart  
Sensing  
condition  
Distance  
Description  
Step  
adjuster  
Operation  
ON  
Detection  
Turn the distance adjuster fully counterclockwise  
to the minimum sensing range position. (0.2 m  
0.656 ft approx.)  
normal operation  
OFF  
1
ON  
Turn fully  
Detection ON-delay  
T
T
OFF  
Please an object at the required distance from the  
sensor, gradually turn the distance adjuster clock-  
wise to determine point a, where the sensor  
changes to the detecting state.  
ON  
Detection OFF-delay  
T
T
T
T
2
3
4
OFF  
ON  
Detection ON / OFF-delay  
Remove the object. Continue turning the adjuster  
clockwise until the sensor enters the detecting  
state again. Then turn the distance adjuster back  
a little untill the sensor returns to the non-detec-  
ting state, called point b .  
OFF  
ON  
Non-detection  
normal operation  
OFF  
ON  
Non-detection ON-delay  
Non-detection OFF-delay  
T
T
T
If the sensor does not go into the detecting state  
even if the adjuster is turned fully clockwise, point b  
is regarded as the maximum position on the scale.  
OFF  
ON  
T
T
OFF  
Optimum  
position  
ON  
Non-detection  
ON / OFF-delay  
The optimum position to stably detect objects is  
the center point between a and b.  
T
OFF  
Timer period: T = 0.1 to 5 sec. (variable)  
Stability indicator  
DC-voltage type FGS select  
Since the EQ-500 series uses a 2-segment photodiode as its  
receiving element, and sensing is done based on the difference  
in the incident beam angle of the reflected beam from the  
sensing object, the output and the operation indicator (orange)  
operate according to the object distance.  
Furthermore, the stability indicator (green) shows the margin of  
the setting distance.  
Distance  
adjuster  
Description  
Step  
Turn the distance adjuster fully clockwise to the  
maximum sensing range position. (2.5 m 8.202 ft  
approx., 1.0 m 3.281 ft approx. for EQ-512)  
1
Turn fully  
Setting distance  
In the state where the sensor detects the back-  
ground, gradually turn the distance adjuster coun-  
terclockwise, to determine point a where the  
sensor changes to the non-detecting state.  
2
3
4
Sensing object  
Output (Operation indicator)  
(In case of Detection-ON)  
ON (Lights up)  
OFF (Lights off)  
Place an object at the required distance from the sensor,  
turn the adjuster counterclockwise further until the sen-  
sor goes into the non-detecting state again. Once enter-  
ed, turn the adjuster backward a little until the sensor re-  
turns to the detecting state, called point b .  
Lights up  
Lights off  
Stability indicator  
Stable operating  
condition  
Stable operating  
condition  
Unstable  
If the sensor does not go into the non-detecting state  
even if the adjuster is turned fully counterclockwise, point  
b is regarded as the maximum position on the scale.  
operating condition  
Others  
Optimum  
position  
Take care that the sensor is not directly exposed to fluorescent  
light from a rapid-starter lamp or a high frequency lighting device,  
as it may affect the sensing performance.  
The optimum position to stably detect objects is  
the center point between a and b .  
Do not use during the initial transient time (50 ms) after the  
power supply is switched on.  
This sensor is suitable for indoor use only.  
Its distance adjuster is mechanically operated. Do not drop; avoid  
other shocks.  
Do not use this sensor in places having excessive vapor, dust,  
etc., or where it may come in direct contact with water, or  
corrosive gas.  
Take care that the sensor does not come in direct contact with  
water, oil, grease or organic solvents, such as, thinner, etc.  
This sensor cannot be used in an environment containing  
inflammable or explosive gases.  
Never disassemble or modify the sensor.  
202  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  
EQ-500  
DIMENSIONS (Unit: mm in)  
EQ-501(T) EQ-502(T)  
Sensor  
EQ-511(T) EQ-512(T)  
Assembly dimensions with sensor mounting bracket  
MS-EQ5-01 (Optional) (Foot angled mounting)  
Stability indicator (Green)  
Distance adjuster (2-turn)  
Operation mode switch (Note 1)  
OFF-delay timer adjuster (Note 2)  
6.5  
0.256  
(30.5)  
(1.201)  
Adjuster indicator  
ON-delay timer adjuster (Note 2)  
29  
1.142  
Operation indicator (Orange)  
4
0.157  
17.5  
0.689  
"6.5  
6.5  
"0.256  
0.256  
58  
2.283  
(10)  
(10)  
2
3-M5 nut seats  
(on both sides)  
(0.394)  
(0.394)  
26  
1.024  
68  
2.677  
0.079  
Beam-  
receiving part  
2-M5 (length 30 1.181) screws  
3-"5.1 "0.201  
mounting holes  
Center of beam-  
emitting  
(Center of sensing)  
68 58  
2.677 2.283  
Center of beam-  
emitting  
(Center of sensing)  
22  
0.866  
58  
2.283  
3.465  
88  
30  
5
1.181  
37  
1.457  
0.197  
18  
0.709  
5
58  
0.197  
2.283  
29  
1.142  
26  
1.024  
5
58  
Notes: 1) The operation mode switch of the DC-voltage type is the DIP switch.  
t 2  
t 0.079  
0.197  
2.283  
2) EQ-5T does not incorporate those.  
78  
3.071  
203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
08/2005  

Miele Washer w 3204 User Manual
Multiquip Portable Generator GA 36RZ3 User Manual
NEC Computer Monitor 2090 User Manual
NEC DVR NHD 3000PVR User Manual
N Tron Switch 702 W User Manual
Panasonic Flat Panel Television Flat Screen TV User Manual
Panasonic Indoor Furnishings ET PKF100S User Manual
Paradyne Network Card 3172 User Manual
Patton electronic Network Card MODEL 1012AR User Manual
Patton electronic Surge Protector Ethernet ThickNet Surge Protector User Manual