Matrix System650EX
Download from Www.Somanuals.com. All Manuals Search And Download.
Key Features of The Satellite System
Matrix System 650EX. Enhancing Large-System Surveillance.
• Multiple System650EX systems with WJ-MPU955A
central processing unit upgraded by WJ-ASC960,
can be linked by video link and Network.
Up to 512 cameras and 64 monitors, plus up to 64-domain Satellite capability
Up to 512
Up to 64
Up to 512
Up to 64
Up to 512
Up to 64
The new Panasonic Matrix System650EX redefines "advanced" in large-system surveillance.
This new EXpanded edition of the world-renowned System650 adds the new WJ-MPU955A
Main CPU, for flexible, fully integrated control of up to 512 cameras and 64 monitors.
Plus, our new WJ-ASC960 software upgrade makes the configuration of systems with up to 64
Satellite domains possible. For anyone needing to construct large scale systems to suit a wider
range of applications such as casinos, airports, transport terminals, banks, shopping complexes,
prisons, or other government facilities, the smarter answer is clear. Matrix System650EX
Up to 64 domains
• Up to of 64 domains.
• Up to 1,024 video links across the domains.
• Up to 512 global operators (total of global and local operators)
and 1,024 global alarms.
Control via IP Network
• Four global operator classes by combination of Global camera lock
and Global camera lock override privileges.
• System650EX, System850 and GX matrix system can be incorporated
to make a hybrid satellite system.
• Integrated Global and Local administration software makes setup easy.
Key Features of The Expanded System
Matrix System650EX Administration Software
Basic Features
The standard software for basic (up to 512 x 64) system.
• Up to 512 inputs and 64 outputs.
Up to 512
• All inputs support multiplexed video, control data and VD2 sync over
Main Menu
Cameras Setup Menu
Recorders Setup Menu
the coaxial cable, and cable compensation up to 900 m (3,000 feet).
• Up to 512 RS-485 remote controlled cameras.
• Supports simultaneous use of 64 controllers including the
WV-CU950 System Controllers and Personal Computers
Up to 64
using ActiveX control interface.
Alarm Functions
• Up to 1,024 alarm programs and various alarm interfaces including 1,024 terminal
inputs, 256 terminal outputs, 512 camera alarms, 512 Video loss alarms and
1,024 serial alarm inputs (Total of terminal inputs and outputs is 1,024).
• Up to ten actions including Camera spot, Tour Sequence, Group Sequence and
Text for each alarm event. Each action can be assigned to one of the 16 targets,
which includes up to 64 monitors.
Alarm Targets Setup Menu
Event Scheduler Setup Menu
• Alarms can be scheduled by programming the timer event function.
• Alarm priority control enables effective management for alarms,
timer events and operators.
General Functions
• Three sequencing features: Tour Sequence; 128 patterns, 64 steps,
Group Preset; 128 patterns, 64 monitors, Group Sequence; 128 patterns, 64 steps.
• Up to 1,024 Timer events including Camera Spot, Tour Sequence, Group Preset,
Group Sequence, Alarm and Mode change.
WJ-ASC960 Upgrade Software for Satellite Configuration
This optional software upgrade allows configuration of systems with up to 64 Satellite domains.
• Full camera control including 255 preset position call, Menu setup, Color/Black &
White Change, Wiper, Defroster and 256 function codes (depending on the camera
model). Preset positions can easily be programmed by the system controller.
• Up to 512 operators with individual level and priority settings,
and flexible system partitioning.
Main Menu
Video Link Setup Menu
• Up to 32 recorders (WJ-HD316/309A, WJ-RT416) can be connected.
* Connection with WJ-RT416 is a plan for future.
• Cameras, matrix and recorders can be controlled seamlessly from
the system controller.
• It will support a redundant CPU system without need of
WJ-MPS850 CPU management switch unit, enabling lower cost.
• Front access for Main Board and Power Supply maintenance.
OSD Service
• Alarm Status, Alarm History (100 events), Video Loss Status, Video Loss History
(100 events) and System Status can be viewed on a monitor.
• Time & Date Displays can be switched on and off from the system controller.
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.
M A J O R F U N C T I O N S
A Rich Array of Features for More Reliable and Efficient Surveillance
Three Sequencing Features for More Efficient Monitoring
Flexible System Partitioning and Priority
These features allow you to determine the sequence in which you seem images from multiple cameras.
System Controller buttons make monitoring more efficient by enabling instant selection of the pattern of your choice.
The System650EX has flexible system partitioning and priority features allowing for advanced operation management.
Partitioning includes Controller to Area, Monitor, Camera view, Camera control, Group Sequence, Alarm, Alarm I/O, Recorder,
Operator-to-Controller and Monitor-to-Camera. Priority control includes Operator, Controller, Alarm and Timer-event so that the flexible
priority control is available. For example, a higher operator will not be bothered by the lower priority alarms or timer events and higher
priority alarms will not be disturbed by the lower priority operators or timer events. In addition, the System650EX can create the Areas
including Monitors, Controllers, Tour Sequences, Group Presets and Group Sequences. All these items, except controllers, can have a
local number enabling the operators to select them by using a simpler reference number.
Tour Sequence
Group Preset
Automatically switches camera images sequentially on the selected
monitor. Up to 128 patterns can be programmed with as many as 64
steps per pattern. Camera preset position (1 ~ 255) and AUX output (1,
2) can also be controlled and up to 86,339 seconds dwell time is
Allows instant spot display of selected camera with preset position (1 ~
255) on up to 64 pre-selected monitors at once. Up to 128 patterns can
be programmed.
Group Preset 128
available in each step.
Partitioning and Priority Overview
Controller-Camera Partition Setup Menu
The image shifts automatically from one camera to another, as programmed.
Group Preset 2
Group Preset 1
step 1
step 2
step 3
step 64
Logical 1 Logical 2 Logical 3 Logical 4 Logical 5
Controller-Camera
Tour 1
C1
C2
C3
C16
C1
C20
C5
C15
M1 M64
ID 1-5
ID 1-5
ID 1-5
ID 6-10
ID 6-10
ID 6-10
Tour 2
Tour 3
C5
C9
C6
C7
C4
C8
Local 1-5
Local 1-5
Local 1-5
Local 1-5
Local 1-5
Local 1-5
Monitor 1
Monitor 2
Monitor 3
Monitor 64
Cont-G.SEQ
Tour
Local -1
G-Preset
Local -2
G-SEQ
Local -3
Tour
Local -1
G-Preset
Local -2
G-SEQ
Local -3
C10
C11
Physical 11 Physical 12 Physical 13
Physical 14 Physical 15 Physical 16
Group Sequence
The images can be
seen on any monitor.
Automatically switches Group preset patterns sequentially. Up to 128
patterns can be programmed with as many as 64 steps per pattern.
Up to 86,339 seconds dwell time is available in each step.
Group Sequence 128
Cam-Mon
Area
Tour 128 C13
C14
C15
C12
Controller-Mon
Controller priority
Tour Sequences Setup Menu
Group Sequences Setup Menu
Controller 1 Controller 2 AREA 1
Controller 3 Controller 4 Controller 5 AREA 2
Group Sequence 2
Group Sequence 1
step 64
Operator to Controller
Operator priority
C1
C20
C5
C15
step 1
User Management for Preventing Unauthorized Access
Monitor 1
Monitor 2
Monitor 3
Monitor 64
Group Presets Setup Menu
Up to 512 operators can be registered with individual operator IDs, passwords and priority (0 to 65,534). 16 operator levels are fully
configurable with numerous parameters such as camera select, alarm select and DVR select.
Administrators for the system setup are registered separately, allowing secure user management.
Up to 1,024 Alarm Events Ensure That You Capture Vital Scenes
Operator Registration Example
Operator Classes Setup Menu
OPE
The Matrix System650EX supports flexible alarm handling, up to 1,024 alarm programs and various alarm interfaces including
1,024 terminal inputs, 256 terminal outputs, 512 camera alarms, 512 Video loss alarms and 1,024 serial alarm inputs (Total of terminal
inputs and outputs is 1,024). An alarm program can activate up to 10 actions including camera spot, Tour Sequence, Group Sequence
and Text. Each action can be assigned to one of the 16 targets, which includes up to 64 monitors, so that the multiple actions can
effectively be displayed across the alarm target monitors.
OPE
2
OPE
6
1
Priority
12123
Level 1
Password
OPE
7
21233
22342
Level 2
OPE
16
Permission Override
Area Change
ALM Select
Area Change
OPE
17
OPE
35
ALM Reset (ALL)
ALM Ack/Reset
ALM Arm/Dis (ALL)
ALM Arm/Dis
ALM Reset (ALL)
ALM Ack/Reset
31256
34682
An alarm terminal output can be triggered when an alarm is activated, acknowledged or reset.
Example:Terminal Alarm Event No.256
Level 3
ALM Arm/Dis
ALM Status Svc
34397
31625
ALM Status Svc
ALM History Svc
Output Ports
ALM Status Svc
Level 4
Alarm ID Priority Alarm Source Alarm Output
Action
• Alarms can be scheduled by programming the timer
event function.
Output Ports
CAM Select
CAM Pos
No.
0
1
Type
ID Preset AUX Dwell Time
Text
Target
CAM Select
CAM Select
CAM Pos
CAM Select
CAM Pos
Camera spot
Camera spot
Tour SEQ
1
2
1
1
–
–
1
OFF
–
3sec
5sec
3sec
Entrance 1 Zoom
Entrance 1 Wide
Entrance Area
1 (M1, M2)
1 (M1, M2)
2 (M11, M12)
CAM Preset Prg
CAM Menu On/Off
CAM Function Cds
CAM Receiver
CAM Setup Data
CAM Lock
CAM Menu On/Off
CAM Function Cds
CAM Receiver
• Alarm priority control enables effective management
for alarms, timer events and operators.
• Up to 1,024 Alarm Program status, up to 100 events
of Alarm History and up to 100 events of Video-loss
History can be viewed on a monitor.
• Up to 30 days of Alarm logs can be stored in the main
CPU unit.
• Alarms can be suspended individually by Arm/Disarm
button from the system controller.
OPE
500
OPE
512
256
1
Terminal
513
2
CAM Receiver
CAM Lock
CAM Lock
CAM Lock Override
CAM Lock
8
9
Group SEQ
Text only
1
–
–
–
–
–
4 sec
–
Group level 1
Entrance 1 Level 1 16 (M63, M64)
3 (M31, M32, M33,M34)
CAM Lock Override
DVR Select
39262
33681
Level 16
DVR Ctrl
OPERATOR’S LEVEL TABLE
Tour Sequence
Group Sequence
Group Preset
Camera 1
WJ-SX650
Alarm Output 513
Group Sequence
Group Sequence
Group Preset
SEQ Stop (ALL)
Group Sequence
Group Sequence
SEQ Stop (ALL)
Group Preset
SEQ Stop (ALL)
SEQ Controller Prg
Video Loss Svc
MON Select
SEQ Stop (ALL)
SEQ Stop (ALL)
Camera 2
Preset Position 1
Video Loss Svc
MON Select
(Zoom in to Entrance 1)
MON Select
MON Lock
OSD On/Off
Terminal
Alarm 256
Action 1
Camera 2
Target 1 M2
Time & Date On/Off
Time & Date On/Off
Time & Date On/Off
Time & Date On/Off
Time & Date On/Off
Entrance 1
• Hold mode displays first alarm while sequence mode
displays multiple alarms sequentially when multiple
alarms are activated.
Action 2
Tour SEQ1
Target 2 M11
C1
C2
C3
Timer Events for Simple, Certain Operation
M11 M11 M11
Sensor
Camera spot, Tour Sequence, Group Preset,
Group Sequence, Alarm arm/disarm and Mode
change features can automatically be activated,
following programmed schedules. Up to 1,024
timer events can be registered.
Setup Example
Event ID Priority
Action 8
Group SEQ1
Target 3 M31, 32, 33, 34
Action
ID
–
Monitor
Start Date
11 Nov. 2006
11 Nov. 2006
11 Nov. 2006
Start Time
08:00
End Date
End Time Repeat
Sensor
System
C1
C20
M32
C5
C15
M34
1
2
3
5
5
Alarm Disarm
Alarm Arm
–
–
1
–
–
–
Daily
Daily
ZOOM
M31
M33
–
17:00
–
Infrared
Sensor
10
Camera spot
1
08:00
31 Jan. 2007
17:00
Weekly
Action 0
Camera 1
Target 1 M1
Action 9
•
•
•
Text
Entrance 1
Level 1
Target 16 M63
1,024
20
Tour SEQ
3
4
1 Dec. 2006
09:00
1 Dec. 2006
18:00
Once
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
P R O D U C T C O N F I G U R A T I O N
S Y S T E M E X A M P L E S
An expanded full matrix configuration for a maximum 512-camera x 64-output system.
Matrix Switcher: WJ-SX650
Video Input Board: WJ-PB65C32
SPECIFICATIONS
SPECIFICATIONS
Power Source
120 V AC, 60 Hz
60 W
Camera Input
1 V [p-p] / 75 Ω (BNC x 32), composite video signal
Camera
Camera
Camera
Camera
Camera
Camera
Camera
Camera
256 225
224 129
128 33
32
1
257 288
289 384
385 480
481 512
Power Consumption
(CAMERA IN 1 ~ 32)
0.5 V [p-p] / 75 Ω data signal and
Ambient Operating Temperature –10 °C ~ +50 °C (14 °F ~ 122 °F)
2.5 V [p-p] / 75 Ω vertical timing pulse multiplexed
1 V [p-p] / 75 Ω (25pin D-sub connector x 4),
active loop-thru output
Ambient Operating Humidity
Video Input Board
Less than 90 %
Video Output
(VIDEO OUT 1 ~ 4)
Alarm Input
x 1
Video Output Board
Expansion Slot
x 1
N.O. (Normally Open contact) or
x 1
(ALARM IN)
N.C. (Normally Close contact) selectable x 32 (37pin D-sub connector)
MXSW11
MXSW12
RS-485 (Camera) Port
6-conductor modular jack x 4 (2-wire or 4-wire communication,
With termination switches (MODE 1 ~ 4))
420 mm x 265 mm x 372 mm (16-9/16" x 10-7/16" x 14-3/5")
(excluding rubber feet and projections)
19.0 kg (42 lbs.)
Dimensions (W x H x D)
Main Board
IN X-2 Board
WJ-CA65L07K
(1~256 x 1~32)
(257~512 x 1~32)
346 mm x 42 mm x 225 mm (13-3/5" x 1-3/5" x 8-4/5")
355 mm x 21 mm x 115 mm (14" x 4/5" x 4-1/2")
355 mm x 38 mm x 115 mm (14" x 1-1/2" x 4-1/2")
MXSW114
MXSW113 MXSW112
MXSW111
MXSW121
MXSW122 MXSW123
MXSW124
Dimensions (W x H x D)
Weight
in
in
in
in
in
in
in
out2
out1/NW Board
in
out2
out1/NW Board
in
in
in
in
in
in
IN X-1 Board
BNC x 32
BNC x 32
Bridge1 (1~32)
Bridge11
Bridge12
in
WJ-SX650U
in
Video Output Board: WJ-PB65M16
in
out2
out1/NW Board
WJ-SX650U
WJ-SX650U
WJ-SX650
WJ-SX650
WJ-SX650U
WJ-SX650U
WJ-SX650U
Card Cage: WJ-SX650U
SPECIFICATIONS
in
WJ-SX650U
SPECIFICATIONS
Monitor Output
(MONITOR OUT 1 ~ 16)
Data Port (DATA 1 ~ 4)
DATA 1
1 V [p-p] / 75 Ω (BNC x 16)
WJ-CA68 x 4
WJ-CA68 x 12
WJ-CA68 x 12
WJ-CA68 x 4
WJ-CA68 x 4
WJ-CA68 x 12
WJ-CA68 x 12
WJ-CA68 x 4
WJ-SX650
Expansion Slot
x 3
monitor
x 32
RS-485 (Camera) Port
6-conductor modular jack x 12 (2-wire or 4-wire communication,
With termination switches (MODE 1 ~ 4))
6-conductor modular jack x 2
MXSW214
MXSW213
MXSW212
MXSW211
MXSW221
MXSW222
MXSW223
MXSW224
Terminal Mode (TMNL)/PS•Data (PS•DATA) selectable
Terminal Mode (TMNL)
in
in
in
in
in
in
in
out2
out1/NW Board
in
out2
out1/NW Board
in
in
in
in
in
in
Bridge2 (33~64)
BNC x 32
DATA 2
DATA 3, 4
BNC x 32
Extension Port
Terminal Mode (TMNL)/Digital Disk Recorder (HDR) selectable
(EXTENSION 1 IN, OUT) (With a termination switch (TERM: ON, OFF))
Bridge21
Bridge22
in
in
6-conductor modular jack x 4 (With termination switches (MODE 1
~
4))
Extension Port
37pin D-sub connector x 2
in
Alarm Output (ALARM OUT 1, 2)
Alarm Output
Alarm Recover Input
Time Adjust Input
Time Adjust Output
Extension Port
(EXTENSION 1 IN, OUT)
VS Input
VS Output
Serial Port
Dimensions (W x H x D)
Main Board
OUT X-3 Board
OUT X-2 Board
(EXTENSION IN 2, 3)
Extension Port
(EXTENSION OUT 2, 3)
Dimensions (W x H x D)
WJ-HD316A x 2
monitor x 2
WJ-HD316A x 6
monitor x 6
WJ-HD316A x 6
monitor x 6
WJ-HD316A x 2
monitor x 2
out2
out1/NW Board
WJ-HD316A x 2
monitor x 2
WJ-HD316A x 6
monitor x 6
WJ-HD316A x 6
monitor x 6
WJ-HD316A x 2
monitor x 2
Open collector output x 32, Max. 24 V DC, 100 mA
Non-voltage make contact input x 16
Non-voltage make contact input x 1
Open collector output x 32, Max. 24 V DC, 100 mA
6-conductor modular jack x 2
in
37pin D-sub connector x 2
WJ-SX650
WJ-SX650U
MXSW21 (1~256 x 33~64)
MXSW22 (257~512 x 33~64)
420 mm x 265 mm x 372 mm (16-9/16" x 10-7/16" x 14-3/5")
(excluding rubber feet and projections)
18.0 kg (40 lbs.)
monitor
x 32
Weight
Model No.
WJ-SX650
Description
Q'ty
(With a termination switch (TERM: ON, OFF))
1 V [p-p] / 75 Ω (VS IN)
32 in x 16 out Matrix Switcher
Card Cage
6
14
30
6
WJ-SX650U
WJ-PB65C32
WJ-PB65M16
WJ-PB65E01
HUB
(VS OUT (THRU)): VS loop-thru output, (VS OUT): 1 V [p-p] / 75 Ω (VS)
32ch Video Input Board
16ch Video Output Board
Network Board
9pin D-sub connector x 2
6
WJ-MPU955A
346 mm x 42 mm x 225 mm (13-3/5" x 1-3/5" x 8-4/5")
355 mm x 21 mm x 115 mm (14" x 4/5" x 4-1/2")
355 mm x 21 mm x 115 mm (14" x 4/5" x 4-1/2")
355 mm x 38 mm x 115 mm (14" x 1-1/2" x 4-1/2")
WJ-CA65L07K 0.7 m Expansion Cable Kit *
14
128
1
WJ-CA68
D-sub/BNC Video Cable
Main CPU Unit
HUB
WJ-MPU955A
WV-CU950
OUT X-1 Board
Ethernet System Controller **
2
PTZ Dome Camera / Fixed Camera
Monitor (for Switcher)
512
64
32
32
16ch Digital Disk Recorder
Monitor (for Recorder)
Central Processing Unit: WJ-MPU955A
Network Board: WJ-PB65E01
PC
WV-CU950
* Cable length depends on the cage layout.
Front View
Front View
** Number of controller depends on system configuration.
Note: MXSW and Bridge are only descriptive labels and neither product names nor model numbers.
<Front panel attached>
481.2(18-15/16")
Up to 64 domains can be connected in a satellite configuration.
Domain #1
Domain #2
Domain #3
System850 + GX system
WJ-GXE900
Domain #64
System650EX [512 x 64]
System650EX + GX system
(1 256)
(257 512)
<Front panel detached>
WJ-GXE900
WJ-GXD900
WJ-SX650#1
(256 x 32)
WJ-SX650#2
(256 x 32)
WJ-GXD900
Rear View
WJ-CA68
Video
Link
Video
Link
WJ-SX850
MXCONT
WJ-SX650#3
(64 x 32)
Rear View
420(16-9/16")
WJ-SX650#4
(256 x 32)
WJ-SX650
MXSW
WJ-SX650
MXSW
WJ-SX650#5
(256 x 32)
WJ-SX850
MXSW
WJ-CA68
WJ-CA68
Ethernet Port
WJ-SX850
MXOSD
WJ-SX650#6
WJ-SX850
Alarm Output Ports 1, 2
VS Input Connector
VS Output Loop-thru Connector
VS Output Connector
Serial Port
Operation Indicator
Screws
Operation Switch
Redundant Selector Peripheral Interface Ports
Ethernet Ports
(64 x 32)
Bridge
Fan Alarm Indicator
Hard Disk Drive Indicator
Active Indicator
Mode Selector
Reset Button
Test Ports
Cooling Fan Unit
Power Switch
AC Inlet Socket
WJ-ASC960 WJ-MPU955A
WV-CU950
WJ-ASC960 WJ-MPU955A
WV-CU950
WJ-ASC960 WJ-MPU955A
WV-CU950
SPECIFICATIONS
SPECIFICATIONS
Power Supply
NTSC model: 120 V AC, 60 Hz
60 W
Ethernet Port
Alarm Output Port 1, 2
VS Input
10Base-T/100Base-TX, RJ-45 x 1
Power Consumption
Ethernet Ports
Open collector output x 32, Max. 24 V DC, 100 mA
1 V [p-p] / 75 Ω (VS IN)
System650EX only : up to 512 x 64 / Domain
10Base-T/100Base-TX, RJ-45 x 3
System controller* (1 port), System device (1 port), other (1 port)
* Maximum 64 controllers
Up to 64 domains.
System850 only
GX only
: up to 1,024 x 256 / Domain
: up to 1,024 x 256 / Domain
VS Output
(VS OUT (THRU)): VS loop-thru output
(VS OUT): 1 V [p-p] / 75 Ω (VS)
IP Network
Each domain needs the WJ-ASC960 Upgrade Software.
In one domain, the System650EX and the System850
cannot be mixed.
RS-232C Port
9pin D-sub connector x 2
Serial Port
9pin D-sub connector x 1
System650EX + GX : up to 512 x 64 + GX 1,024 x 256 / Domain
System850 + GX : up to 1,024 x 256 + GX 1,024 x 256 / Domain
Ambient Operating Temperature +5 °C ~ +45 °C (41 °F ~ 113 °F)
Dimensions (W x H x D)
355 mm x 38 mm x 134 mm (14" x 1-1/2" x 5-3/10")
Ambient Operating Humidity
Dimensions (W x H x D)
Less than 90 %
420 mm x 88 mm x 350 mm (16-9/16" x 3-7/16" x 13-3/4")
(excluding rubber feet and projections)
9 kg (19.8 lbs.)
Note: MXSW, MXCONT, MXOSD and Bridge are only descriptive labels and neither product names nor model numbers.
Weight
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
|