Panasonic Power Supply KW4S User Manual

Eco-POWER METER  
Simple Watt-Hour Meter  
KW4S  
On the lookout for wasted electricity!  
Now even more powerful  
with communication function  
and easy PLC connection!  
CT  
Building  
Plant  
Air conditioner  
PC  
Line process  
Lights  
Elevator  
Constant-temperature oven  
Eco-3 Brothers  
Integrated  
electrical  
energy  
For maintenance and  
control in applications  
involving energy  
Electricity  
charge  
Voltage  
Current  
Eco-POWER METER  
Eco-COUNT METER  
Keeping a watchful eye.  
saving and environmental protection  
Eco-HOUR METER  
KW4S  
Eco-POWER METER  
ARCT1B247E ’05.1  
Panasonic...the new name for  
Matsushita Electric Works, Ltd.  
01/2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Always on the lookout for wasted electricity, Eco-POWER METER is  
there to assist in the energy-saving activities of all customers.  
Configuration Examples  
(Alone and as system)  
Eco-POWER METER  
1. Standalone measurement  
4. Gathering data with PLC  
Dedicated CT  
MEWTOCOL  
Pulse output  
2. Data management with PLC  
5. Managing data  
with Web Datalogger Unit  
3. Data management with computer  
(Using data collection software)  
Gathering power consumption data from each manufacturing machine  
Example  
3
Automatic gathering of electrical power  
Using spreadsheet software such as Excel, data  
2
can be freely edited (turned into graphs) and  
saved. Daily and monthly reports can be  
created.  
Data from each machine is  
collected using the Eco-POWER  
METER dedicated data collection  
software (AKW4805) and then  
saved as a CSV file.  
1
Using RS485 (reduced wiring with two twisted pair cables), up to 31 Eco-POWER METERs can be connected.  
Shrink-  
wrapping  
machine  
01/2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Eco-POWER METER KW4S  
Electric power watching in manufacturing lines  
Example  
Electric power watching using PLC with Eco-POWER METER  
4
Email function also included  
Have your mobile phone  
notified by email if there is  
a significant increase in  
electric power usage.  
PCWAY  
(Operation Data Managing Software)  
FPΣ  
Using RS485 (reduced wiring with two twisted pair cables),  
up to 99 Eco-POWER METERs can be connected.  
Pie graph  
Line graph  
Electric power data collection and remote watching of plants and buildings  
Example  
Electric power watching using Web Datalogger Unit with Eco-POWER METER  
5
Gathering of logged data  
• Power meter  
• Water meter  
• Dynamometer • Gas meter  
Air conditioner  
Remotely manage collected data on the Web.  
Lights  
Supermarket  
Office automation  
Internet  
Telephone infrastructure  
All types of networks  
Web  
Datalogger  
Unit  
Outlets  
Supermarket  
Building  
Web  
Datalogger  
Unit  
Web  
Datalogger  
Unit  
Food warehouse  
Plant  
Download from Www.Somanuals.com. All Manuals Search And Download.  
01/2005  
Eco-POWER METER KW4S  
System Diagram  
Web  
Datalogger  
Unit  
Up to  
99  
Eco-POWER METERs can be connected!  
or  
FP-e  
PC used for data  
gathering and management  
Installation is easy using a CT even  
for the power lines of existing equipment  
and machinery.  
Power line  
Shrink-wrapping  
machine  
CT  
• Please see the catalog (ARCT1E208E) for details on the Web Datalogger Unit.  
• Please see the “FP series Programmable Controllers” catalog (ARCT1B230E) for details on the FP-e and FP0 PLC.  
Dimensions  
Eco-POWER METER  
mm inch  
KW4S  
1) Pin type  
5.5  
2) Screw terminal type  
48  
1.890  
87.5  
3.445  
Display: Integrated electrical  
14.5  
.571  
5.5  
.217  
energy, Voltage, Current  
and Electricity charge  
.217  
Eco-POWER METER KW4S  
(44.5)  
(1.752)  
(44.5)  
(1.752)  
MODE  
SET  
V
kWh  
CHARGE  
A
73  
2.874  
81.9  
3.224  
Types and Specifications  
Types  
Current  
Changes  
Communication protocol  
Features added  
Only dedicated protocol  
Dedicated protocol and MEWTOCOL  
1 to 99 (Note)  
Station number setting  
1 to 31  
Setting start  
Communication format change  
Setting start Protocol switch (dedicated or MEWTOCOL) →  
Communication format setting  
Change  
Communication format change  
Above content and communication procedure added.  
Instruction Manual  
Note:You must use 1 to 31 when selecting the dedicated protocol (Eco-POWER METER data collection software: AKW4805).  
Communication specifications  
MEWTOCOL-COM commands  
The Eco-POWER METER supports five commands.  
Interface  
Conforming to RS485  
Our method  
Protocol  
RD: Data area read command  
Isolation status  
No. of connected units  
Transmission distance  
Isolated with internal circuit  
99 units*  
WD: Data area write command  
MD: Monitor data save and save reset command  
MG: Monitor execute command  
RT: Status read command  
1,200m  
Transmission speed (Baud rate) 2,400, 4,800, 9,600, 19,200 bps (In each setting mode, settings can be made with front panel keys.)  
Data length  
Parity  
7-bit/8-bit (In each setting mode, settings can be made with front panel keys.)  
Transmission  
data format  
Not available/Odd/Even (In each setting mode, settings can be made with front panel keys.)  
*We recommend the SI-35 of Lineeye Co., Ltd., for the  
RS485 converter on the PC side. (When using SI-35,  
FP2-CB485 (for FP2-MCU), FPΣ (COM3 and COM4) or  
FP-e, the maximum number you can connect is 99. When  
using with devices other than these, the maximum  
number will be limited to 31.)  
Stop bit  
1 bit (Fix)  
Communication method  
Synchronous method  
Terminating resistor  
Half duplex  
Start-stop synchronous method  
Approx. 120Ω (internal)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
01/2005  
Eco-POWER METER KW4S  
KW4S Eco-POWER METER  
1. Electricity meter that acts like an  
3. Log and track data of integrated  
industrial component (DIN size: 48×48)  
Eco-POWER METER is both compact and  
inexpensively priced. It is easy to install on your  
existing equipment and machinery.  
electrical energy usage  
It is easy to load the power usage pulse output into a  
PLC or counter.  
4. Centrally manage integrated electrical  
2. Digitally display integrated electrical  
energy, voltage, and current  
Adopts the RS485 for communication specification.  
This allows you to log data (integrated  
electrical energy, voltage, and current)  
from up to 99 units on a PC and PLC.  
energy and electricity charges  
You can digitally display integrated electrical energy,  
voltage, current, and electricity charges. This is  
handy for managing energy-saving.  
Eco-POWER METER  
Dedicated CT  
Product types  
Product name  
Phase and wire system  
Rated input  
Current transformer  
Terminal type  
Part No.  
Screw terminal AKW4111  
Single-phase two-wire system  
Single-phase three-wire system  
Three-phase three-wire system  
Dedicated CT type  
100 to 120/  
200 to 240V AC  
11-pins  
AKW4211  
Eco-POWER METER Main unit  
Screw terminal AKW4121  
Commercial CT type  
11-pins  
AKW4221  
AKW4801  
AKW4805  
Only used for AKW4111, AKW4211  
Dedicated current transformer (CT)  
Data collection software for Eco-POWER METER  
KC2S Eco-COUNT METER/KE2S Eco-HOUR METER  
1. Easy to install on existing  
5. Two installation methods available  
machinery  
(Separate models)  
Just attach the dedicated CT to your existing  
cables. There is no need to install any additional  
cabling.  
Two installation methods are available: The extremely  
easy-to-use one-touch installation, and the installation  
frame installation, used for timers/counters (protective  
construction IP66). Select the installation type that  
suits the location.  
2. Built-in battery  
The built-in battery allows the units to be installed  
anywhere.  
6. Letter's height is 8.7 mm  
A large LCD panel is used, with a highly legible 8.7  
mm letter’s height.  
3. Economically priced  
Eco-COUNT METER  
Eco-HOUR METER  
4. Compact size doesn't take up  
7. Conform to CE marking (EMC  
directive)  
space (DIN 24 x 48)  
Easy to install even in cramped spaces.  
Product types  
KC2S Eco-COUNT METER  
Product Name  
Installation type  
Front reset  
Available  
Measurement count range  
0 to 99999999  
Part No.  
AKC2421  
AKC2621  
AKE2811  
Installation frame type*2  
Eco-COUNT METER main unit*1  
Intermediate power cable*3  
One-touch installation type  
KE2S Eco-HOUR METER  
Product Name  
Installation type  
Front reset  
Available  
Measurement count range  
0 to 99999.9h  
Part No.  
AKE2421  
AKE2621  
AKE2811  
Installation frame type*2  
Eco-HOUR METER main unit*1  
Intermediate power cable*3  
One-touch installation type  
Notes: 1. Eco-HOUR METER (AKE2421/AKE2621) is a product package consisting of the main unit, an exclusive use current transformer (CT), and trunk cable.  
2. Only the installation frame installation type includes rubber gasket and installation frame.  
3. The maximum allowable current of the intermediate power cable is 15 A.  
These materials are printed on ECF pulp.  
These materials are printed with earth-friendly vegetable-based (soybean oil) ink.  
Please contact ..........  
Matsushita Electric Works, Ltd.  
Automation Controls Business Unit  
Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan  
Telephone: +81-6-6908-1050  
Facsimile: +81-6-6908-5781  
All Rights Reserved © 2005 COPYRIGHT Matsushita Electric Works, Ltd.  
Specifications are subject to change without notice. Printed in Japan.  
ARCT1B247E 200501-3YT  
01/2005  
Download from Www.Somanuals.com. All Manuals Search And Download.  

NEC Server HV8600 User Manual
NETGEAR Switch GS108E 100NAS User Manual
NETGEAR Switch GS205 User Manual
New Holland Lawn Mower T1510 User Manual
NordicTrack Treadmill NETL15520 User Manual
NuTone Fan 765HFL User Manual
Oracom Modem MX160 User Manual
Panasonic Fax Machine KX F780 User Manual
Panasonic Network Card 2SC4562G User Manual
Panasonic Vacuum Cleaner MC UL675 User Manual