F565726
Operating Instructions
Air Conditioner
Indoor Unit
Outdoor Unit
CU-E7GKR
CU-E9GKR
CU-E12GKR
CS-E7GKR
CS-E9GKR
CS-E12GKR
Before opperatiinng the uunit, reead theese opeerratingg instrucctioonnss tthhoorroouugghhllyy aanndd kkeeeepp tthheemm ffoorr ffuuttuurree rreeffeerreennccee..
QUICK GUIDE
Manufactured by:
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site,
40300 Shah Alam, Selangor, Malaysia.
© 2007 Panasonic HA Air-Conditioning (M) Sdn. Bhd. (11969-T). All rights
reserved. Unauthorized copying and distribution is a violation of law.
Download from Www.Somanuals.com. All Manuals Search And Download.
Thank you for purchasing
Air Conditioner
RREEGGUULLAATTOORRYY IINNFFOORRMMAATTIIOONN
The appliance is not intended for use by young children or the infirm person without
supervision. Young children should be supervised to ensure that they do not play
with the appliance.
TABLE OF CONNTENTS
SAFETY PRECAUTIONS
2
OPERATION CONDITION
Use this air conditioner under the following temperature range
REGULATORY INFORMATION
3
Indoor
Outdoor
PRODUCT OVERVIEW &
OPERATIONS
Temperature (°C)
Maximum
*DBT
*WBT
*DBT
*WBT
26
4~5
6
32
16
30
16
23
11
-
43
16
24
-5
COOLING
CARE & CLEANING
TROUBLESHOOTING
QUICK GUIDE
Minimum
Maximum
Minimum
11
18
HEATING
-
-6
7
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
BACK COVER
NOTE :
The illustrations in this manual are
for explanation purposes only and
may differ from the actual unit. It is
subjected to change without notice
for future improvement.
ENVIRONMENTAL REQUIREMENTS
Battery Disposal
The batteries must be recycled or disposed of properly.
END-OF-LIFE DISPOSAL
“Instructions for end-user” for air conditioners:
Information on Disposal in other countries outside the European Union
This symbol is only valid in the European Union. If you wish to discard this product, please contact your
installer, dealer or local authority and ask for the correct method of disposal.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PPRROODDUUCCTT OOVVEERRVVIIEEWW && OOPPEERRAATTIIOONNSS
Auto OFF/ON button
e-ion AIR PURIFYING SYSTEM
•
Used when remote control is misplaced
or malfunction.
Do not touch during operation
Active e-ion Power
Action
Mode
e-ion filters
Active e-ion Generator
Press once.
Auto
Module
Press and hold until 1 beep
is heard, then release.
Cooling
Heating
Front panel
Press and hold until 1 beep
is heard, then release.
Press again until 2 beeps,
then release.
Press the button to turn off.
INDICATOR
Horizontal airflow
direction louver
• Manually
Vertical airflow
adjustable.
direction louver
• Do not adjust
by hand.
Receiver
TO TURN ON OR OFF THE UNIT
Remote control
display
• Please be aware of the OFF indication on the remote control
display to prevent the unit from starting / stopping improperly.
TO SET TEMPERATURE
• Selection range: 16˚C ~ 30˚C.
• Operating the unit within the recommended temperature could
induce energy saving.
HEAT mode : 20˚C ~ 24˚C.
COOL mode : 26˚C ~ 28˚C.
DRY mode : 1˚C ~ 2˚C lower than room temperature.
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• Unit selects operation mode every 30 minutes according to
temperature setting, outdoor and room temperature. During
operation mode selection the power indicator blinks.
HEAT mode - To enjoy warm air
• Unit takes a while to warm up. The power indicator blinks during
this operation.
COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling operation.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
TO SET THE TIMER
TO SELECT FAN SPEED
(5 OPTIONS)
• To turn ON or OFF the unit at a preset time.
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
Select ON or
OFF timer.
Set the time.
Confirm.
or then
TO ADJUST VERTICAL AIRFLOW
DIRECTION (5 OPTIONS)
• To cancel ON or OFF timer, press
press
.
• Keeps the room ventilated.
• If AUTO is set, the louvers swing up/down
automatically.
• In heat mode, the air blows horizontally for a while,
then starts to blow downwards.
• When ON Timer is set, the unit may start earlier (up
to 30 minutes) before the actual set time in order to
achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote
control and repeats daily once set. For clock setting,
please refer to Remote Control Preparation at back
cover.
TO MONITOR AIR QUALITY
• Patrol sensor detects air quality.
• When air quality is unsatisfactory, e-ion operation will
start automatically.
• If timer is cancelled manually or due to power failure,
you can restore the previous setting (once power is
resumed) by pressing
.
TO ENJOY CLEAN AIR
• This operation produces negative ions to attract dust
which will then be captured at the positively charged
e-ion filters.
OPTIONNAL SETTINGS
Patrol starts automatically with the unit
switched on with
.
TO ENJOY QUIET ENVIRONMENT
• This operation reduces airflow noise.
Press and hold for 5 seconds, then release
to disable or restore this setting.
TO ACHIEVE TEMPERATURE
QUICKLY
Press and hold for 5 seconds to dim or
restore the unit’s indicator brightness.
• This operation will stop automatically after 20
minutes.
Press and hold for approximately 10
seconds to show temperature setting in
°C or °F.
Press and hold for approximately 5 seconds
to show 12-hour (am/pm) or 24-hour time
indication.
Press to restore the remote control’s default
setting.
•
,
,
and
can be activated
Not used in normal operations.
in all modes and can be cancelled by pressing the
respective button again.
,
Set the temperature 1°C higher in cool mode or 2°C
lower in heat mode than the desired temperature to
achieve a 10% power saving.
•
•
and
or
and
can not
be activated at the same time.
and can be activated even when the
Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
unit is turned off. In this condition, once e-ion indicator
is ON, the unit will operate with AUTO fan speed and
air swing.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE & CLEANING
•Switch off the power supply before cleaning.
•Do not touch the aluminium fin, sharp part may cause injury.
CAUTION
HINTS
WASHING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap ( pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
• Clean the filter regularly for best performance and to
reduce power consumption.
• Please consult your nearest dealer for seasonal
inspection.
ALUMINIUM FIN
FRONT PANEL
Raise and pull to remove. Wash
gently and dry.
INDOOR UNIT
Wipe the unit gently with a soft,
dry cloth.
Remove
ACTIVE e-ion GENERATOR
Clean with dry cotton bud.
• Active e-ion generator
cleaning is recommended
every 6 months.
e-ion FILTERS
• Clean the filters regularly.
• Wash/rinse the filters gently with water
to avoid damage to the filter surface.
• Dry the filters thoroughly under
the shade, away from fire or direct
sunlight.
ACTIVE e-ion POWER MODULE
• Replace any damage filter.
FOR SEASONAL INSPECTION AFTER EEXXTTEENNDDEEDD
NON-USE
• Checking of remote control batteries.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then CALL Authorized
Distributor under the following conditions:
• No obstruction at air inlet and air outlet vents.
• Abnormal noise during operation.
• After 15 minutes of operation, it is normal to have the
following temperature difference between air inlet and air
outlet vents:
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
Cooling: ≥ 8°C
Heating: ≥ 14°C
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
FOR EXTENDED NON-USE
• Activate heat mode for 2~3 hours to thoroughly dry the unit.
• Turn off the power supply.
• Remove the remote control batteries.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
TTRROOUUBBLLEESSHHOOOOTTIINNGG
The folllowinngg symptooms do nnot iinnddiiccaatte mmaallffuunnccttiioonn..
Symptom
Cause
Mist emerges from indoor unit.
Water flowing sound during operation.
The room has a peculiar odour.
• Condensation effect due to cooling process.
• Refrigerant flow inside the unit.
• This may due to damp smell emitted by the wall, carpet, furniture or
clothing.
Indoor fan stops occasionally during automatic • This helps to remove the surrounding odours.
fan speed setting.
Operation is delayed a few minutes after
restart.
• The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam.
Timer indicator is always on.
• Condensation or evaporation occurs on pipes.
• The timer setting repeats daily once set.
Power indicator blinks during operation and
the indoor fan is stopped.
• The unit is in defrost mode, and the melted frost is drained from the
outdoor unit.
Indoor fan stops occasionally during heating
operation.
• To avoid unintended cooling effect.
Power indicator blinks before the unit is
switched on.
• This is a preliminary step in preparation for the operation when the ON
timer has been set.
Cracking sound during operation.
• Changes of temperature cause the expansion/contraction of the unit.
Checkk the folllowinng befoorre calliing forr sserviicing.
Symptom
Check
Heating/Cooling operation is not working
efficiently.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the filters.
• Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation.
• Check if the unit has been installed at an incline.
• Close the front panel properly.
Remote control does not work.
• Insert the batteries correctly.
(Display is dim or transmission signal is weak.) • Replace weak batteries.
The unit does not work.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
The unit does not receive the signal from the
remote control.
• Make sure the receiver not obstructed.
• Certain fluorescent lights may interfere with signal transmitter. Please
consult your nearest dealer.
Patrol sensor or e-ion indicator on the indoor
unit is blinking.
• Press
or
twice. If the patrol sensor or e-ion indicator still
blinking, please consult your nearest dealer.
The unnit stoops anndd the tiimer inndicattor blinks.
NOTE :
Press until you hear
beep sound, then jot
down the error code.
Press for 5
seconds.
2
1
3
• The unit may be operable
(with 4 beeps) on a limited
basis, depending on the
error.
Press for 5
seconds to quit
checking.
• Turn the unit off and reveal the error code to your nearest dealer.
Download from Www.Somanuals.com. All Manuals Search And Download.
7
QUICK GUIDE
Remote Control Preparation
Press and pull out
1
2
Insert AAA or R03 batteries (can be used ~ 1 year)
2
6
Press CLOCK
Set time
3
4
5
6
1
Confirm
Close the cover
4
5
3
1
Select the desired mode.
AUTO HEAT
DRY COOL
2
Start/stop the operation.
3
Set the desired temperature.
Matsushita Electric Industrial Co., Ltd.
Printed in Malaysia
F565726
OFTH0706-01
Download from Www.Somanuals.com. All Manuals Search And Download.
|