Thank you for purchasing
Panasonic Air Conditioner
RREEGGUULLAATTOORRYY IINNFFOORRMMAATTIIOONN
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
TABLE OF CONTENTS
SAFETY PRECAUTIONS
2
REGULATORY INFORMATION
3
OPERATION CONDITION
Use this air conditioner under the following temperature range
(CU-E18JKR, CU-E21JKR)
PRODUCT OVERVIEW &
OPERATIONS
4~5
6
Indoor
Outdoor
CARE & CLEANING
TROUBLESHOOTING
QUICK GUIDE
Temperature (°C)
Maximum
*DBT
*WBT
*DBT
*WBT
26
32
16
30
16
23
11
-
43
16
24
-5
COOLING
7
Minimum
Maximum
Minimum
11
18
BACK COVER
HEATING
-
-6
NOTE :
(CU-E24JKR, CU-E28JKR)
The illustrations in this manual are
for explanation purposes only and
may differ from the actual unit. It is
subjected to change without notice
for future improvement.
Indoor
Outdoor
Temperature (°C)
*DBT
32
*WBT
*DBT
43
*WBT
26
Maximum
23
11
-
COOLING
HEATING
Minimum
Maximum
Minimum
16
16
11
30
24
18
16
-
-10
-11
* DBT: Dry bulb temperature
* WBT: Wet bulb temperature
Information for Users on Collection and Disposal of Old Equipment and used Batteries
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your
local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the
requirement set by the Directive for the chemical involved.
Pb
• Do not switch ON the unit when waxing the floor. After waxing, aerate the room properly before operating the unit.
• Do not install the unit in oily and smoky areas.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PPRROODDUUCCTT OOVVEERRVVIIEEWW && OOPPEERRAATTIIOONNSS
e-ion AIR PURIFYING SYSTEM
Auto OFF/ON button
•
Used when remote control is misplaced or
malfunction.
Do not touch during operation
Action
Mode
Auto
e-ion filters
e-ion charging wire
Active e-ion Generator
Press once.
Press and hold until 1 beep is
heard, then release.
Press and hold until 1 beep is
heard, then release.
Press again until 2 beeps, then
release.
Cooling
Heating
Front panel
Press the button to turn off.
INDICATOR
Receiver
(Blue)
(Green)
(Orange)
(Orange)
(Orange)
(Green)
(Blue)
Airflow direction
louver
• Do not adjust
by hand.
Maximum distances: 8m
POWER
TO TURN ON OR OFF THE UNIT
Remote control
display
MODE
• Please be aware of the OFF indication on the remote control
display to prevent the unit from starting / stopping improperly.
TO SET TEMPERATURE
• Selection range: 16˚C ~ 30˚C.
• Operating the unit within the recommended temperature could
induce energy saving.
OFF/ON
ECONOMY
HEAT mode : 20˚C ~ 24˚C.
COOL mode : 26˚C ~ 28˚C.
DRY mode : 1˚C ~ 2˚C lower than room temperature.
TEMP
TO SELECT OPERATION MODE
MILD DRY
MODE
AIR SWING
QUIET/ POWERFUL
AUTO mode - For your convenience
• Unit selects operation mode every 30 minutes according to
temperature setting, outdoor and room temperature. During
operation mode selection the power indicator blinks.
1
2
3
SET
ON
HEAT mode - To enjoy warm air
• Unit takes a while to warm up. The power indicator blinks during
this operation.
OFF
CANCEL
TIME
SET
CHECK CLOC
COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling operation.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
TO SET THEE TIMER
TO SELECT FAN SPEED
(5 OPTIONS)
• 2 sets of ON and OFF timers are available to turn ON or
OFF the unit at different preset time.
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
Set the
time.
Select ON or OFF Timer
Confirm.
AIR SWING
TO ADJUST AIRFLOW DIRECTION
(5 OPTIONS)
¥1
¥2
Cancel
Cancel
TIMER
¥1
¥2
• Example of application at living room:
Morning: ON ¥1 at 07:00 (Wake up)
OFF ¥1 at 08:00 (Out for work)
Evening: ON ¥2 at 17:00 (Back home)
OFF ¥2 at 22:00 (Sleep)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swing
left/right and up/down automatically.
• In HEAT mode, if AUTO is set, the horizontal louver fix
at predetermined position. The vertical louver swing
left/right after the temperature rises.
• To cancel ON or OFF timer, press
or
to
TO MONITOR AIR
QUALITY
• Patrol sensor detects air quality.
• When air quality is unsatisfactory, e-ion operation will
start automatically.
select respective ¥1 or ¥2 then press
.
• If timer is cancelled manually or due to power failure,
you can restore the timer again by pressing
or
to select respective ¥1 or ¥2 then press
.
TO SAVE ELECTRICAL
POWER CONSUMPTION
ECONOMY
ECONOMY
• Upcoming timer will be displayed and will be activated
in sequence.
• Save power consumption at unoccupied room by
adjust set temperature up to 3°C automatically.
• Brightness of all indicators will be dimmed.
• When ON Timer is set, the unit may start earlier (up
to 35 minutes) before the actual set time in order to
achieve the desired temperature on time.
QUIET/ POWERFUL
QUIET
POWERFUL
NORMAL
• Timer operation is based on the clock set in the remote
control and repeats daily once set. For clock setting,
please refer to Remote Control Preparation at back
cover.
TO ENJOY QUIET ENVIRONMENT
• This operation reduces indoor and
outdoor units noise.
QUIET
TO ACHIEVE TEMPERATURE QUICKLY
• This operation will stop automatically
after 20 minutes.
POWERFUL
OPTIONAL SSETTINGS
TO IMPROVE HUMIDITY
AND MOISTURE LEVEL
Patrol starts automatically with the unit
MILD DRY COOLING
MILD DRY
switched on with
.
• This operation reduces air dryness and provides you
with a comfortable living environment.
• When vertical airflow direction is set to AUTO, it
stops at lower position to avoid cold air contact.
However, you can adjust the louver direction
manually.
Press and hold for 5 seconds, then release
to disable or restore this setting.
Press and hold for 5 seconds to dim or
restore the unit’s indicator brightness.
QUIET/ POWERFUL
ECONOMY
Press and hold for approximately 10
seconds to show temperature setting in
°C or °F.
•
,
and
can be activated in
all modes and can be cancelled by pressing the
respective button again.
MILD DRY
•
•
•
only can be activated in COOL mode and can
Press to restore the remote control’s default
setting.
be cancelled by pressing the button again.
QUIET/ POWERFUL
MILD DRY
ECONOMY
,
and
cannot be activated at
Not used in normal operations.
the same time.
,
can be activated even when the unit is turned
off. In this condition, once e-ion operation is ON, the
unit will operate with AUTO fan speed and air swing.
Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE & CLEANING
•Switch off the power supply before cleaning.
•Do not touch the aluminium fin, sharp parts may cause injury.
CAUTION
HINT
WASHING INSTRUCTIONS
• Do not use benzene, thinner or scouring powder.
• Use only soap ( pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
• To ensure optimal performance of the unit, cleaning
maintenance have to be carried out at regular intervals.
Dirty unit may caused malfunction and you may retrieve
error code “H99”. Please consult authorized dealer.
FRONT PANEL
Remove Front Panel
• Raise and pull to remove
the front panel.
ALUMINIUM FIN
• Wash gently and dry.
Close Front Panel
• Press down both ends of the
front panel to close it securely.
Remove
e-ion CHARGING WIRE
INDOOR UNIT
Wipe the unit gently with a soft,
dry cloth.
e-ion FILTERS
• Clean the filters regularly.
• Wash/rinse the filters gently with water
to avoid damage to the filter surface.
• Dry the filters thoroughly under
the shade, away from fire or direct
sunlight.
ACTIVE e-ion GENERATOR
Clean with dry cotton bud.
• Active e-ion
generator cleaning is
recommended every 6
months.
• Replace any damage filter.
FOR SEASONAL INSPECTION AFTER EEXXTTEENNDDEEDD
NON-USE
• Checking of remote control batteries.
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult
authorized dealer under the following conditions:
• No obstruction at air inlet and air outlet vents.
• Abnormal noise during operation.
• Use Auto OFF/ON button to select Cooling/Heating operation,
after 15 minutes of operation, it is normal to have the following
temperature difference between air inlet and air outlet vents:
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
Cooling: ≥ 8°C
Heating: ≥ 14°C
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
FOR EXTENDED NON-USE
• Activate Heat mode for 2~3 hours to remove moisture left in
the internal parts thoroughly to prevent mould growth.
• Turn off the power supply.
• Remove the remote control batteries.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
TTRROOUUBBLLEESSHHOOOOTTIINNGG
The folllowinngg symptooms do nnot iinnddiiccaatte mmaallffuunnccttiioonn..
Symptom
Cause
Mist emerges from indoor unit.
Water flowing sound during operation.
The room has a peculiar odour.
• Condensation effect due to cooling process.
• Refrigerant flow inside the unit.
•
This may due to damp smell emitted by the wall, carpet, furniture or clothing.
Indoor fan stops occasionally during automatic • This helps to remove the surrounding odours.
fan speed setting.
Airflow continues even after operation has
stopped
• Extraction of remaining heat from the indoor unit (maximum 30 seconds).
.
Operation is delayed a few minutes after restart. • The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam.
Timer indicator is always on.
• Condensation or evaporation occurs on pipes.
• The timer setting repeats daily once set.
Power indicator blinks during operation, the
indoor fan is stopped and vane is closed.
• The unit is in defrost mode, and the melted frost is drained from the
outdoor unit.
Indoor fan stops occasionally during heating
operation.
• To avoid unintended cooling effect.
Power indicator blinks before the unit is
switched on.
• This is a preliminary step in preparation for the operation when the ON
timer has been set.
Cracking sound during operation.
• Changes of temperature cause the expansion/contraction of the unit.
Checkk the folllowinng befoorre calliing forr sserviicing.
Symptom
Check
Heating/Cooling operation is not working
efficiently.
• Set the temperature correctly.
• Close all doors and windows.
• Clean or replace the filters.
• Clear any obstruction at the air inlet and air outlet vents.
Noisy during operation.
• Check if the unit has been installed at an incline.
• Close the front panel properly.
Remote control does not work.
• Insert the batteries correctly.
(Display is dim or transmission signal is weak.) • Replace weak batteries.
The unit does not work.
• Check if the circuit breaker is tripped.
• Check if timers have been set.
The unit does not receive the signal from the
remote control.
• Make sure the receiver not obstructed.
• Certain fluorescent lights may interfere with signal transmitter. Please
consult your nearest dealer.
PATROL operation does not work.
• Press and hold
again.
for 15 seconds until beep sound is heard, press
Patrol sensor indicator on the indoor unit is
blinking.
• Press
twice. If the patrol sensor indicator still blinking, please
consult authorized dealer.
The unnit stoops anndd the tiimer inndicattor blinks.
Use remote control to retrieve error code.
Note:
Press until you hear
beep sound, then jot
down the error code.
Press for 5
seconds.
• For certain error, you may
restart the unit with limited
operation with 4 beeps
during operation starts.
2
1
3
Press for 5
seconds to quit
checking.
Turn the unit off and reveal the error code to authorized dealer.
4
7
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK GUIDE
Remote Conntrol PPreparration
Press and pull out
1
2
Insert AAA or R03 batteries (can be used ~ 1 year)
2
6
Press CLOCK
Set time
3
4
5
6
1
Confirm
Close the cover
4
5
3
1
Select the desired mode.
AUTO HEAT
MODE
DRY COOL
2
Start/stop the operation.
OFF/ON
ECONOMY
TEMP
MILD DRY
MODE
3
AIR SWING
QUIET/ POWERFUL
Set the desired temperature.
1
2
3
ON
SET
OFF
CANCEL
TIME
SET
CHECK CLOC