Panasonic Air Conditioner CS C12PKF 3 User Manual

Operating Instructions  
Air Conditioner  
Model No.  
Indoor Unit  
Outdoor Unit  
CS-C12PKF-3  
CS-C18PKF-3  
CS-C24PKF-3  
CU-C12PKF-3  
CU-C18PKF-3  
CU-C24PKF-3  
Operating Instructions  
Air Conditioner  
Thank you for purchasing Panasonic Air Conditioner.  
Installation instructions attached.  
Before operating the unit, read these operating  
instructions thoroughly and keep them for future  
reference.  
F568979  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick guide  
Table of contents  
Inserting the batteries  
Safety precautions...................4-5  
How to use...............................6-7  
To learn more... ......................8-9  
Cleaning instructions................10  
Troubleshooting........................ 11  
Information.................Back cover  
1
1
2
3
Pull out the back cover of  
remote control  
2
3
Insert AAA or R03 batteries  
(can be used ~ 1 year)  
Close the cover  
2
3
Clock setting  
TIMER  
ON  
3
1
2
3
Press CLOCK  
Set the time  
Conrm  
1
OFF  
CANCEL  
RESET  
Accessories  
SET  
1
• Remote control  
• AAA or R03 batteries × 2  
• Remote control holder  
• Screws for remote control  
holder × 2  
Basic operation  
Select the desired mode  
AUTO  
1
AUTO  
COOL  
DRY  
FAN  
DRY  
COOL  
SPEED  
AIR  
SWING  
Start/stop the operation  
2
AUTO  
2
3
1
ECONAVI  
COMFORT  
NANOE-G  
POWER/AVS  
• Please note that the OFF  
POWERFUL/  
QUIET  
indication  
is on to start.  
AIR SWING  
FAN SPEED  
3
Select the desired  
temperature  
• Selection range:  
16 °C ~ 30 °C.  
TIMER  
ON  
SET  
3
1
2
OFF  
CANCEL  
RESET  
Operating the unit within the  
recommended temperature  
may save energy.  
SET  
CLOCK  
COOL: 26 °C ~ 28 °C.  
DRY : 1 °C ~ 2 °C lower than  
room temperature.  
To dim or restore the unit’s  
indicator brightness, press  
and hold for 5 seconds.  
8m  
• Use remote control within 8 m  
from the remote control receiver  
of the indoor unit.  
The illustrations in this manual are for explanation purposes  
only and may differ from the actual unit. They are subject to  
change without notice for future improvement.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety precautions  
To prevent personal injury, injury to others  
or property damage, please comply with the  
following:  
WARNING  
Incorrect operation due to failure to follow  
instructions below may cause harm or damage,  
the seriousness of which is classied as below:  
Indoor unit and outdoor unit  
This appliance is not intended for use by  
persons (including children) with reduced  
This sign warns of  
physical, sensory or mental capabilities, or lack  
of experience and knowledge, unless they have  
been given supervision or instruction concerning  
use of the appliance by a person responsible for  
their safety. Children should be supervised to  
ensure that they do not play with the appliance.  
death or serious  
injury.  
WARNING  
CAUTION  
This sign warns of  
injury or damage to  
property.  
Please consult authorised dealer or specialist to  
clean the internal parts, repair, install, remove  
and reinstall the unit. Improper installation and  
handling will cause leakage, electric shock or re.  
The instructions to be followed are classied by  
the following symbols:  
This symbol denotes an  
action that is PROHIBITED.  
Conrm with authorised dealer or specialist on  
usage of any specied refrigerant type.  
Using refrigerant type other than the specied  
may cause product damage, burst and injury etc.  
Do not install the unit in a potentially explosive  
or ammable atmosphere. Failure to do so could  
result in re.  
These symbols denote  
actions COMPULSORY.  
Do not insert your ngers or other  
objects into the air conditioner indoor or  
outdoor unit, rotating parts may cause  
injury.  
Do not touch the outdoor unit during lightning, it  
may cause electric shock.  
Do not expose yourself directly to cold air for a  
long period to avoid excess cooling.  
Power supply  
Indoor unit  
Do not sit or step on the unit, you may  
fall down accidentally.  
Air inlet  
Remote control  
Air outlet  
Do not allow infants and small children to play  
with the remote control to prevent them from  
accidentally swallowing the batteries.  
Remote control  
Air inlet  
Power supply  
Outdoor unit  
Air outlet  
Do not use a modied cord,  
joint cord, extension cord or  
unspecied cord to prevent  
overheating and re.  
To prevent overheating, re or electric shock:  
Do not share the same power outlet with other  
equipment.  
Do not operate with wet hands.  
Do not over bend the power supply cord.  
Do not operate or stop the unit by inserting or  
pulling out the power plug.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Use complete power supply cord without  
joining. In unavoidable circumstances that  
complete power supply cord without joining  
is impossible, use an approved connection  
means (for example: socket and plug).  
CAUTION  
Indoor unit and outdoor unit  
Power  
Supply  
Air Conditioner  
Do not wash the indoor unit with water,  
benzine, thinner or scouring powder to  
avoid damage or corrosion at the unit.  
Indoor Unit  
Do not use for preservation of precise  
equipment, food, animals, plants, artwork  
or other objects. This may cause quality  
deterioration, etc.  
Complete wire  
without joining  
Complete  
wire without  
joining  
OR  
Do not use any combustible equipment in front  
of the airow outlet to avoid re propagation.  
Do not expose plants or pet directly to airow  
Approved connecting  
means (for example:  
approved socket and  
plug)  
to avoid injury, etc.  
Outdoor  
Unit  
Do not touch the sharp aluminium  
n, sharp parts may cause injury.  
Do not switch ON the indoor unit when waxing  
the oor. After waxing, aerate the room  
properly before operating the unit.  
If the supply cord is damaged, it must be  
replaced by the manufacturer, service agent  
or similarly qualied persons in order to avoid  
a hazard.  
Do not install the unit in oily and smoky areas  
to prevent damage to the unit.  
It is strongly recommended to be installed  
with Earth Leakage Circuit Breaker (ELCB)  
or Residual Current Device (RCD) to prevent  
electric shock or re.  
Do not dismantle the unit for cleaning purpose  
to avoid injury.  
Do not step onto an unstable bench when  
cleaning the unit to avoid injury.  
To prevent overheating, re or electric shock:  
Insert the power plug properly.  
Dust on the power plug should be  
periodically wiped with a dry cloth.  
Do not place a vase or water container on the  
unit. Water may enter the unit and degrade the  
insulation. This may cause an electric shock.  
Stop using the product if any abnormality/  
failure occurs and disconnect the power plug  
or turn off the power switch and breaker.  
(Risk of smoke/re/electric shock) Examples  
of abnormality/failure  
Do not open window or door for long time  
during COOL/DRY mode operation.  
Prevent water leakage by ensuring drainage  
pipe is:  
- Connected properly,  
The ELCB trips frequently.  
- Kept clear of gutters and containers, or  
- Not immersed in water  
Burning smell is observed.  
Abnormal noise or vibration of the unit is  
observed.  
After a long period of use or use with any  
combustible equipment, aerate the room  
regularly.  
Water leaks from the indoor unit.  
Power cord or plug becomes abnormally hot.  
Fan speed cannot be controlled.  
The unit stops running immediately even if it  
is switched on for operation.  
The fan does not stop even if the operation  
is stopped.  
After a long period of use, make sure the  
installation rack does not deteriorate to  
prevent the unit from falling down.  
Remote control  
Contact your local dealer immediately for  
maintenance/repair.  
Do not use rechargeable (Ni-Cd) batteries. It  
may damage the remote control.  
This equipment must be earthed to prevent  
electrical shock or re.  
To prevent malfunction or damage of the  
remote control:  
Remove the batteries if the unit is not going  
to be used for a long period of time.  
New batteries of the same type must be  
inserted following the polarity stated.  
Prevent electric shock by switching off the  
power supply and unplug:  
- Before cleaning or servicing,  
- When extended non-use, or  
- During abnormally strong lightning activity.  
Power supply  
Do not disconnect the plug by pulling the cord  
to prevent electric shock.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to use  
ECONAVI  
To optimise energy saving  
Human activity  
sensor and  
indicator  
ECONAVI  
Sunlight sensor  
and remote  
control receiver  
MODE  
To select operation mode  
Indicator  
AUTO - For your convenience  
• Unit selects the operation mode according to  
the room temperature.  
• Once AUTO mode is selected, the unit will  
operate at the standard setting temperature.  
POWER/AVS  
TIMER  
(Orange/Green)  
(Orange)  
Remote control  
display  
(Green)  
ECONAVI  
AUTO COMFORT  
NANOE-G  
(Green)  
(Blue)  
Room  
Standard setting  
temperature  
Operation mode  
temperature  
POWERFUL/QUIET  
(Orange/Green)  
23˚C & above  
COOL  
DRY  
25˚C  
Below 23˚C  
22˚C  
AUTO  
COOL  
DRY  
FAN  
SPEED  
• Press  
for “HI” to +2˚C or  
for “LO” to -2˚C  
AIR  
to the standard setting temperature.  
SWING  
COOL - To enjoy cool air  
To reduce power consumption during COOL  
mode, use curtains to screen off sunlight and  
outdoor heat.  
OFF/ON  
DRY - To dehumidify the environment  
• Unit operates at low fan speed to give a gentle  
cooling operation.  
Press and hold for  
approximately  
10 seconds to show  
temperature setting in  
°C or °F.  
TEMP  
TIMER  
ON  
SET  
3
POWERFUL/  
QUIET  
To switch between  
1
2
powerful & quiet  
Press to restore the  
remote control to  
default setting.  
OFF  
CANCEL  
POWERFUL  
QUIET  
NORMAL  
CLOCK  
POWERFUL: To reach temperature quickly  
Not used in normal  
operations.  
POWERFUL  
This operation will stop automatically after 15  
minutes.  
FAN SPEED  
QUIET: To enjoy quiet operation  
To select fan speed  
QUIET  
• This operation reduces airow noise.  
(Remote control display)  
• For AUTO, the indoor fan speed is automatically  
adjusted according to the operation mode.  
Auto OFF/ON button  
Use when remote control is misplaced or a malfunction occurs. Raise the front panel:  
To use in AUTO mode, press the button once.  
To use in COOL mode, press and hold the button until 1 beep is heard, then  
release.  
• Press the button again to turn off.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
See "To learn more..." for details.  
To set the timer  
AUTO  
COMFORT  
To maximise comfort  
To purify the air  
To turn ON or OFF the unit at a preset time.  
AUTO COMFORT  
1
2
3
NANOE-G  
TIMER  
ON  
SET  
1
2
3
NANOE-G  
• nanoe-G starts automatically when the unit is  
OFF  
CANCEL  
OFF/ON  
turned on with  
.
Select ON or OFF  
timer  
Example:  
OFF at 22:00  
1
• Can be activated even when the unit is turned  
off. In this condition, the unit will operate as a fan  
with AUTO fan speed and louver swing.  
OFF  
To deactivate viruses/bacteria on the lter  
NANOE-G  
POWER  
Set the time  
2
3
2
• After the unit is turned off, the nanoe-G in-lter  
deactivation may activate up to 150 minutes.  
Turning on the unit cancels this operation.  
SET  
Conrm  
To disable this operation in the future, press and  
NANOE-G  
hold  
until a short beep sound is heard. This  
will not disable the nanoe-G to purify the air.  
TIMER  
To restore the nanoe-G in-lter deactivation,  
NANOE-G  
press and hold  
heard.  
until a long beep sound is  
ON  
To cancel ON or OFF timer, press  
then press  
or  
OFF  
.
CANCEL  
• If timer is cancelled manually or due to power  
failure, you can restore the previous setting  
SET  
AIR SWING  
To adjust airow direction  
(once power is resumed) by pressing  
.
• When ON Timer is set, the unit may start  
earlier (up to 15 minutes) before the actual  
set time in order to achieve the desired  
temperature on time.  
(Remote control display)  
• Timer operation is based on the clock set in  
the remote control and repeats daily once set.  
For clock setting, please refer to Quick guide.  
• Keeps the room ventilated.  
• In COOL/DRY mode, if AUTO is set, the louver  
swings left/right and up/down automatically.  
• Do not adjust the louver by hand.  
Note  
POWERFUL/  
QUIET  
POWERFUL/  
QUIET  
AUTO  
AUTO  
NANOE-G  
ECONAVI  
ECONAVI  
COMFORT  
COMFORT  
,
,
,
,
,
• Can be activated in all modes and can be  
cancelled by pressing the respective button  
again.  
• Cannot be selected at the same time.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
To learn more...  
Operation mode  
COOL: Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode.  
DRY : Unit operates at low fan speed to give a gentle cooling operation.  
nanoe-G in-lter deactivation  
Depending on the unit’s accumulated operation time, nanoe-G in-lter deactivation may activate only once a day after  
the unit turned off.  
To remove the moisture left in the internal parts, the fan will operate for 30 minutes with louver opened slightly. This  
process only applicable when the unit is operated in COOL/DRY mode before turned off. Then, nanoe-G deactivates  
viruses/bacteria on the lter for 2 hours with fan stopped and louver closed.  
Do not turn off the power supply during this operation. After power failure, this operation will not resume.  
ECONAVI and AUTO COMFORT  
AUTO  
ECONAVI  
COMFORT  
Note  
or  
When manual AIR SWING is selected,  
the ECONAVI and AUTO COMFORT  
operations will be cancelled.  
AIR SWING  
The human activity sensor  
and the sunlight sensor will  
start to detect.  
The unit will start to initialise  
(for approximately 1 minute)  
Human activity sensor operation  
ECONAVI ; Detecting human presence and activity, the unit controls room temperature to save energy.  
Human  
Low activity  
Normal activity  
High activity  
Absent  
+2 °C  
Mode  
+1 °C  
Set  
temperature  
COOL/DRY  
AUTO COMFORT ; Detecting human presence and activity, the unit controls room temperature to keep human  
comfortable consistently.  
Human  
Low activity  
Normal activity  
High activity  
Absent  
+2 °C  
Mode  
+1 °C  
Set  
temperature  
-1 °C  
COOL/DRY  
+1 tap  
Set  
Fan Speed  
*
During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.  
** During human absence, maximum fan speed for COOL/DRY mode is medium fan.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
The human activity sensor will also scan for area of heat source and movement in a room.  
Detection area  
Human activity indicator  
120º  
7m  
At left area  
At center / multiple area  
At right area  
The unit judges human activity area for a few seconds before indicator updates. Based on area activeness  
horizontal airow direction louver will adjust either x at predetermined position or swing left/right periodically.  
• The human activity sensor performance is inuenced by indoor unit location, movement speed, temperature  
range, etc.  
• The human activity sensor may:  
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.  
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.  
• Do not place large objects near the sensor and keep away heating units or humidier from the sensor’s detection  
area. They may cause sensor malfunction.  
Sunlight Sensor operation  
ECONAVI is activated,  
the unit maintains set  
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.  
Ambient condition  
temperature until a high  
sunlight intensity is detected.  
The sunlight sensor detects  
sunlight intensity during  
weather or day/night  
Mode  
+1 °C  
Set  
temperature  
COOL/DRY  
changes, and the unit adjusts  
temperature.  
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.  
Automatic Voltage Switcher (AVS)  
When power supply is unstable, where the AC voltage supplied is below 185 V or above 260 V, AVS will  
switch off the outdoor unit to protect the compressor. During this condition, the AVS indicator will turn on.  
Indicator  
Green  
Indoor unit  
ON  
Outdoor unit  
ON  
POWER/AVS  
Orange  
ON  
OFF  
Note: Room temperature may rise during AVS ON.  
Operation conditions  
Use this air conditioner under the following temperature range.  
DBT : Dry bulb temperature  
WBT : Wet bulb temperature  
Indoor  
Outdoor  
Temperature (°C)  
DBT  
32  
WBT  
23  
DBT  
55  
WBT  
31  
Max.  
Min.  
COOL  
16  
11  
16  
11  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleaning instructions  
To ensure optimal performance of the unit,  
cleaning has to be carried out at regular  
intervals. Please consult authorised dealer.  
Indoor unit  
Front panel  
Aluminium n  
• Switch off the power supply and unplug before  
cleaning.  
• Do not touch the aluminium n, sharp parts may  
cause injury.  
• Do not use benzine, thinner or scouring powder.  
• Use only soap ( pH 7) or neutral household  
detergent.  
POWER/AVS  
TIMER  
ECONAVI  
AUTO COMFORT  
NANOE-G  
POWERFUL/QUIET  
• Do not use water hotter than 40 °C.  
Human activity  
sensor  
nanoe-G  
Generator  
Air lters  
Indoor unit  
Wipe the unit gently with a soft,  
dry cloth.  
nanoe-G Generator  
Every 6 months  
• Clean with dry cotton bud.  
• Do not touch during operation.  
Human activity sensor  
Do not hit or violently press or poke it with a sharp  
object. This can lead to damage and malfunction.  
Air lters  
Every 2 weeks  
• Wash/rinse the lters gently  
with water to avoid damage to  
the lter surface.  
Front panel  
Wash gently and dry.  
• Dry the lters thoroughly under shade, away  
from re or direct sunlight.  
• Replace any damaged lters.  
Remove the front panel  
Pull out  
2
Remove air lter  
Attach air lter  
1 Raise  
POWER/AVS  
TIMER  
ECONAVI  
AUTO COMFORT  
NANOE-G  
POWERFUL/QUIET  
Close it securely  
1 Insert at  
both sides  
Insert into the unit  
Press both ends of  
the front panel  
3
For seasonal inspection after extended  
non-use  
• Checking of remote control batteries.  
• No obstruction at air inlet and air outlet vents.  
• After 15 minutes of operation, it is normal to  
have the following temperature difference  
between air inlet and air outlet vents:  
COOL: 8 °C  
POWER/AVS  
TIMER  
ECONAVI  
AUTO COMFORT  
NANOE-G  
POWERFUL/QUIET  
For extended non-use  
Activate nanoe-G operation for 2~3 hours as an  
alternative to remove moisture left in the internal  
parts thoroughly to prevent mould growth.  
2
4
Close down  
For CS-C18PKF-3, CS-C24PKF-3:  
Press at center of the front panel.  
• Turn off the power supply and unplug.  
• Remove the remote control batteries.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
The following symptoms do not indicate malfunction.  
Symptom  
Cause  
Mist emerges from indoor unit.  
Water owing sound during operation.  
The room has a peculiar odour.  
• Condensation effect due to cooling process.  
• Refrigerant ow inside the unit.  
• This may be due to damp smell emitted by the wall,  
carpet, furniture or clothing.  
Indoor fan stops occasionally during automatic • This helps to remove the surrounding odour.  
fan speed setting.  
Operation is delayed a few minutes after  
restarting.  
• The delay is a protection to the unit’s compressor.  
Outdoor unit emits water/steam.  
TIMER indicator is always on.  
Cracking sound during operation.  
• Condensation or evaporation occurs on pipes.  
• The timer setting repeats daily once set.  
• Changes of temperature caused the expansion/  
contraction of the unit.  
2 or more human activity indicator turns on  
simultaneously.  
• Judgement of heat source and movement area in  
progress.  
Check the following before calling for servicing.  
Symptom  
Check  
Operation in COOL mode is not working  
efciently.  
• Set the temperature correctly.  
• Close all doors and windows.  
• Clean or replace the lters.  
Clear any obstruction at the air inlet and air outlet vents.  
Noisy during operation.  
• Check if the unit has been installed at an incline.  
• Close the front panel properly.  
Remote control does not work.  
• Insert the batteries correctly.  
(Display is dim or transmission signal is weak.) • Replace weak batteries.  
The unit does not work.  
• Check if the circuit breaker is tripped.  
• Check if timers have been set.  
The unit does not receive the signal from the  
remote control.  
• Make sure the receiver is not obstructed.  
• Certain uorescent lights may interfere with signal  
transmitter. Please consult authorised dealer.  
NON SERVICEABLE CRITERIAS  
TURN OFF POWER SUPPLY AND UNPLUG then please consult authorised dealer under the following  
conditions:  
• Abnormal noise during operation.  
• Water/foreign particles have entered the remote  
control.  
• Circuit breaker switches off frequently.  
• Power cord becomes unnaturally warm.  
• Switches or buttons are not functioning properly.  
• Water leaks from Indoor unit.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Information  
English  
Information for Users on Collection and Disposal of Old Equipment and used Batteries  
[Information on Disposal in other  
Countries outside the European  
Union]  
These symbols are only valid in the  
European Union. If you wish to discard  
these items, please contact your local  
authorities or dealer and ask for the  
correct method of disposal.  
Note for the battery symbol (bottom  
two symbol examples):  
This symbol might be used in  
combination with a chemical symbol.  
In this case it complies with the  
requirement set by the Directive for the  
chemical involved.  
Pb  
Panasonic Corporation  
© Panasonic Corporation 2012  
Printed in Malaysia  
F568979  
FT0812-0  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Food Warmer M Nr 09 898 121 User Manual
Milwaukee Photo Printer MW101 User Manual
MSB Technology TV Converter Box Rev 1 10 2012 User Manual
National Instruments Computer Hardware 4 Channel +_ VDC 16 Bit Simultaneous Sampling Analog Input Devices User Manual
Nexus 21 Boating Equipment Compass Data User Manual
Nilfisk ALTO Vacuum Cleaner SW 700S B User Manual
NorthStar Navigation Car Speaker 961X User Manual
Optimus Speaker 12 Dec User Manual
Orion Car Audio Car Amplifier 220GX User Manual
Panasonic Battery Charger EY0110 U1 User Manual