INTRODUCTION
Wireless Pro Weather Station
with USB upload
Model: WMR88 / WMR88A
Thank you for selecting the Oregon Scientific™ Wireless
Pro Weather Station with USB upload (WMR88 /
WMR88A).
The base station is compatible with other sensors. To
purchase additional sensors, please contact your local
retailer.
USER MANUAL
CONTENTS
Sensors with this logo
unit.
are compatible with this
Introduction............................................................... 1
Packaging contents.................................................. 1
Base station ........................................................... 1
Wind sensor .......................................................... 1
Temperature & humidity sensor ............................. 1
Rain gauge............................................................. 2
Accessories - Sensors............................................. 2
Overview.................................................................... 2
Top view ................................................................. 2
Back view............................................................... 2
LCD display............................................................ 2
Wind sensor ........................................................... 3
Rain gauge............................................................. 3
Outdoor temperature / humidity sensor.................. 3
NOTE Please keep this manual handy as you use
your new product. It contains practical step-by-step
instructions, as well as technical specifications and
warnings you should know about.
PACKAGING CONTENTS
BASE STATION
4 x AA
1
UM-3 1.5V batteries
Getting started.......................................................... 3
Set up remote wind sensor .................................... 3
Set up remote temperature / humidity sensor........ 4
Set up rain gauge................................................... 4
Set up base station ................................................ 4
Verify connection...................................................... 4
Wind sensor ........................................................... 5
Temperature / humidity sensor............................... 5
Rain gauge............................................................. 5
Mounting / placing of sensors................................. 5
Wind sensor ........................................................... 5
Temperature / humidity sensor............................... 5
Rain gauge............................................................. 5
Clock reception......................................................... 6
Clock / Calendar ....................................................... 6
Moon phase............................................................... 6
Auto scanning function ........................................... 7
Weather forecast ...................................................... 7
Temperature and humidity....................................... 7
Temperature and humidity trend ............................ 7
Wind chill / direction / speed................................... 7
UVI / Barometer / Rainfall......................................... 8
UV Index ................................................................ 8
Barometer .............................................................. 8
Rainfall ................................................................... 9
Upload data to PC software..................................... 9
Backlight ................................................................... 9
Reset.......................................................................... 9
Specifications ........................................................... 9
Precautions............................................................. 10
About Oregon Scientific ........................................ 10
EU declaration of conformity ................................ 10
FCC statement ........................................................ 11
1 x USB cable
1 x base station
1 x 6V adaptor
WIND SENSOR
1 x sensor
connector
2 x AA UM-3
1.5V batteries
1 x wind sensor (1
x wind vane above
and 1 x anemometer
below)
4 x screws
(Type A)
1 x round
U- bolt
TEMPERATURE & HUMIDITY SENSOR
1 x table stand
1 x temperature /
humidity sensor
1 x wall mount
bracket
2 x AAA UM-4
1.5V battery
1
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Outdoor wind sensor battery is low
3. Wind speed level indicator
4. Wind speed level description
5. Minimum wind chill is displayed
6. Wind direction display
RAIN GAUGE
Base and funnel:
2
3
C
UVI / Barometer / Rainfall Area
1
1
2
3
1
4
1. Rain gauge
5
6
7
2. Battery compartment
3. RESET button
1. UVI / barometer / rainfall reading is displayed
2. Past 24hrs rainfall is displayed
3. Outdoor UV / rain sensor battery is low
4. UVI / barometric pressure (mmHg, inHg or mb) /
rainfall readings (in or mm) for the current hour
5. UVI level indicator
1
2
6. Maximum UV is displayed
7. UVI / barometric pressure / rainfall historical bar chart
display
D
Clock / Calendar / Moon Phase Area
1
2
1. Funnel
2. Indicator
OUTDOOR TEMPERATURE / HUMIDITY
SENSOR
3
4
5
6
1. AM / PM
2. Time zone offset
3. Timestamp is displayed
4. Clock signal reception indicator
5. Time / date / calendar
6. Moon phase
5
2
1
3
C
F
4
WIND SENSOR
1
2
1. LED status indicator
2. RESET hole
3. °C / °F: Select temperature unit
4. CHANNEL switch
4
5. Battery compartment
GETTING STARTED
NOTE Install batteries in the remote sensors before the
base station matching the polarities (+ and -).
NOTE Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures below
freezing.
3
1. Wind direction
2. Wind vane casing
3. Anemometer
SET UP REMOTE WIND SENSOR
The wind sensor takes wind speed and direction
readings.
4. Solar power socket
The sensor is battery operated. It is capable of transmitting
data to the base station wirelessly within an approximate
operating range of 100 meters (328 feet).
3
Download from Www.Somanuals.com. All Manuals Search And Download.
To insert batteries:
SET UP BASE STATION
NOTE Install batteries in the remote sensors before the
base station matching the polarities (+ and -).
2
1
1. Unscrew the anemometer from the wind sensor
carefully.
For continuous use, please install the AC adaptor. The
batteries are for back-up use only.
2. Insert batteries matching the polarities (+ / -) and
replace the anemometer. Press RESET after each
battery change.
NOTE Make sure the adaptor is not obstructed and is
easily accessible to the unit.
NOTE The base station and adaptor should not be
exposed to wet conditions. No objects filled with liquid,
such as vases, should be placed on the base station
and adaptor.
SET UP REMOTE TEMPERATURE / HUMIDITY
SENSOR
The remote sensor can collect data from up to 3 channels.
To completely disconnect from power, unplug adaptor
from the mains.
To set up the remote sensor:
1. Slide open the battery door.
2. Slide channel switch to select a channel (1, 2, 3).
Ensure you use a different channel for each sensor.
3. Insert the batteries, matching the polarities (+ / -).
4. Press RESET after each battery change.
5. Close the battery door.
To insert batteries:
SET UP RAIN GAUGE
The rain gauge collects rain and takes rainfall readings.
The sensor can remotely transmit data to the base
station.
1. Slide open the battery door.
To set up the rain gauge:
2. Insert the batteries, matching the polarities (+ / -).
3. Press RESET after each battery change.
4. Close the battery door.
NOTE Do not use rechargeable batteries. It is
recommended that you use alkaline batteries with this
product for longer performance.
2
NOTE Batteries should not be exposed to excessive
heat such as sunshine or fire.
1
The battery icon indicator
following areas:
may appear in the
1. Remove screws and slide the cover off in an upwards
motion.
AREA
MEANING
2. Insertthebatteries(2xUM-3/AA),matchingthepolarities
(+ / -). Press RESET after each battery change.
Battery in the base station is
low.
adaptor is disconnected.
Weather Forecast
Area
will show when AC
The displayed channel
indicates the outdoor sensor
for which battery is low.
Temperature or
Humidity Area
Wind Speed / Wind
Direction / Wind Chil
Area
Battery in the wind sensor
is low.
3
UVI / Barometer /
Rainfall Area
Battery in the UV / Rain
sensor is low.
3. Remove the fibre tape.
VERIFY CONNECTION
Before proceeding to install sensors outside, please verify
communication to the base station.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
a. Align the back of the sensor connector to an existing
pole. Secure in place by inserting the ends of the
U-bolt into the holes on the sensor connector and
securing it with washers and bolts.
WIND SENSOR
OR
b. Insert 4 type A screws into the holes of the sensor
connector. Screw firmly into place, i.e., fence.
Slide wind vane onto the smaller end of the sensor
connector.
Press SELECT until the selected area icon is in the
top right display area.
•
•
Wind speed: Gently rotate the wind vane and confirm
a numerical reading on the base station, e.g.,
.
Wind direction indicator. Move the direction of the
wind indication and verify the icon moves in the same
IMPORTANT Ensure that the wind sensor is pointing
North to enable it to record accurate readings.
direction
.
TEMPERATURE / HUMIDITY SENSOR
TEMPERATURE / HUMIDITY SENSOR
1. Press SELECT until the selected area icon
is in
1.5 m (5 ft)
the bottom left display area.
2. Press UP / DOWN to select channel 1
and verify
a numerical reading.
RAIN GAUGE
1. Press SELECT until the selected area icon
TIP Ideal placements for the sensor would be in any
location on the exterior of the home at a height of not
more than 1.5 m (5 ft) and which can shield it from direct
sunlight or wet conditions for an accurate reading.
is in
the middle right display area.
2. Press MODE until
is displayed.
3. Tilt the tipping funnel on the rain gauge several times
and verify a numerical reading on the base station.
TIP If no reading is displayed for a sensor, press the
SEARCH button on the base station to initiate a wireless
sensor search.
MOUNTING / PLACING OF SENSORS
WIND SENSOR
Secure the sensor in the desired location using the wall
mount bracket or table stand.
NOTE The sensor should be positioned in an open area
away from trees or other obstructions.
RAIN GAUGE
a
b
The base station and rain gauge should be positioned
within an effective range: about 100 meters (328 feet)
in an open area.
The rain gauge should be mounted horizontally about 1
meter (3 feet) from the ground in an open area away from
trees or other obstructions to allow rain to fall naturally
for an accurate reading.
Secure the sensor connector in the desired location:
5
Download from Www.Somanuals.com. All Manuals Search And Download.
To ensure a level plane:
2. Press and hold SEARCH.
Put a few drops of water on the cross at the base of the
funnel to check the horizontal level.
appears when it is enabled.
NOTE For best reception, the base station should be
placed on a flat, non-metallic surface near a window in an
upper floor of your home. The antenna should be placed
away from electrical appliances and not be moved around
when searching for a signal.
1
3
2
CLOCK / CALENDAR
4
To set the clock manually, disable the clock signal
reception first.
To manually set the clock:
(You only need to set the clock and calendar if you have
disabled the clock radio reception.)
Water will pool to the center of the cross when the rain
gauge is level.
If water remains on 1-4, the gauge is not horizontal.
If necessary, adjust the level using the screw.
1. Press SELECT to navigate to the Clock Area.
will
show next to the Area.
2. Press and hold MODE to change the clock setting.
The setting will blink.
3. Press UP / DOWN to increase / decrease the setting
value.
4. Press MODE to confirm.
5. Repeat steps 3 to 4 to set the time zone offset hour
(+ / -23 hours), 12 / 24 hour format, hour, minute,
year, date / month format, month, date and weekday
language.
NOTE For best results, ensure the base is horizontal to
Time zone offset sets the clock +/- 23 hours from the
received clock signal time. If you have deactivated the
clock signal reception, do not set a value for time zone.
allow maximum drainage of any collected rain.
TIP Press RESET button on base station to erase all
testing data.
NOTE If you enter +1 in the time zone setting, this will
give you your regional time plus 1 hour.
CLOCK RECEPTION
This product is designed to synchronize its calendar
clock automatically once it is brought within range of a
radio signal:
If you are in the US (WMR88A only) set the clock to:
PA for Pacific time
CE for Central time
MO for Mountain time
EA for Eastern time
WMR88:
•
EU: DCF-77 signal: within 1500 km (932 miles) of
Frankfurt, Germany.
NOTE The weekday is available in English, German,
French, Italian, Spanish or Russian.
•
UK: MSF-60 signal: within 1500 km (932 miles) of
Anthorn, England.
To change the clock display:
WMR88A:
WWVB-60 signal: within 3200km (2000 miles) of Fort
Collins Colorado.
1. Press SELECT to navigate to the Clock Area. will
show next to the Area.
•
2. Press MODE to toggle between:
•
•
•
Clock with seconds
Clock with weekday
Calendar
WMR88 only - slide the EU / UK switch to the appropriate
setting based on your location. Press RESET whenever
you change the selected setting.
The reception icon will blink when it is searching for a
signal. If the radio signal is weak it can take up to 24
hours to get a valid signal reception.
MOON PHASE
The Calendar must be set for this feature to work (see
Clock / Calendar section).
indicates the status of the clock reception signal.
New
ICON
MEANING
Full Moon
Moon
Time is synchronized.
Receiving signal is strong
Waxing
Waning
Crescent
Gibbous
Time is not synchronized.
Receiving signal is weak
First
quarter
Third
quarter
To enable (and force a signal search when previous
search was unsuccessful) / disable the clock radio
reception:
Waxing
Waning
1. Press SELECT to navigate to the Clock / Calendar /
Gibbous
Crescent
Moon phase Area.
will show next to the Area.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
To view temperature (Current / Max / Min temperature)
readings:
AUTO SCANNING FUNCTION
To activate the outdoor temperature and humidity
auto-scan function:
1. Press SELECT to navigate to the Temperature Area.
will show next to the Area.
1. Press SELECT to navigate to the Temperature or
2. Press UP / DOWN to select the channel.
3. Press MAX / MIN to toggle between current / MAX /
MIN displays.
Humidity Area.
will show next to the Area.
2. Press and hold MODE to activate auto-scan. The
temperature and humidity display will scroll from
indoor to ch1 through to ch3.
To view humidity (Humidity, Dew point) readings:
1. Press SELECT to navigate to the Humidity Area.
will show next to the Area.
3. Press any key to stop the auto-scan.
NOTE Channel 1 is used for the outdoor temperature
and humidity sensor.Additional temperature and humidity
sensors can use other channels.
2. Press UP / DOWN to select the channel.
3. Press MODE repeatedly to toggle between the
humidity / dewpoint displays.
WEATHER FORECAST
4. Press MAX / MIN to toggle between current / MAX /
MIN displays.
This product forecasts the next 12 to 24 hours of weather
forecast within a 30-50 km (19-31 mile) radius.
The timestamp is displayed accordingly in the Clock
Area.
Weather Forecast Area
ICON
DESCRIPTION
To clear the memories and timestamp for the
temperature, humidity and dew point readings:
Sunny
In the Temperature or HumidityArea, press and hold MAX
/ MIN to clear the readings.
Partly cloudy
Cloudy
NOTE The dew point advises at what temperature
condensation will form.
TEMPERATURE AND HUMIDITY TREND
Rainy
The trend lines are shown next to the temperature and
humidity readings. The trend is shown as follows:
RISING
STEADY
FALLING
Snowy
WIND CHILL / DIRECTION / SPEED
TEMPERATURE AND HUMIDITY
The weather station displays indoor and outdoor
readings for:
The base station provides
wind speed and wind
direction information.
1. Temperature / relative humidity (current / maximum
/ minimum)
2. Trend line
To read the wind direction
find the compass point the
is pointing to.
3. Wind chill (current / minimum) and dew point level
(current / maximum / minimum)
The weather station can connect up to 3 remote
sensors.
The timestamp records the date and time when storing
the wind speed readings.
NOTE Channel 1 is dedicated for outdoor temperature
and humidity.
To select the wind speed unit:
shows which remote sensor’s data you are
viewing.
Press UNIT to switch between:
•
•
•
•
Metres per second (m/s)
Kilometers per hour (kph)
Miles per hour (mph)
Knots (knots)
appears when indoor data is displayed.
The timestamp records the date and time when storing the
temperature and humidity readings in memory.
To select the temperature measurement unit:
Press UNIT to select °C / °F.
NOTE The unit of all temperature related displays will
be changed simultaneously.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
To view the UV / Barometer / Rainfall readings:
1. Press SELECT to navigate to the UV / Barometer /
Rainfall Area. will show next to the Area.
2. Press MODE to toggle between UVI / Barometer
/ Rainfall readings. The corresponding icon will
appear:
The wind level is shown by a series of icons:
ICON
LEVEL
DESCRIPTION
N/A
<2 miles/h (<4km/h)
Light
2-8 miles/h (3-13 km/h)
9-25 miles/h (14-41 km/h)
26-54 miles/h (42-87 km/h)
>55 miles/h (>88 km/h)
UVI
BAROMETER
RAINFALL
Moderate
Strong
Storm
To select the measurement unit for the barometer or
rainfall readings:
In the UV / Barometer / Rainfall Area, press UNIT to
switch between:
•
Barometer: Millimeters of mercury (mmHg), inches
of mercury (inHg), millibars per hectopascal (mb).
Rainfall: Millimeters (mm), inches (in), recorded for
that hour.
To view the maximum wind speed and minimum wind
chill readings:
•
1. Press SELECT to navigate to the Wind Speed / Wind
Direction / Wind Chill Area.
Area.
will show next to the
NOTE As the purpose of the bar graph is only to provide
a quick comparison between the records of the past 24
hours, the vertical axis cannot convert from inches to mm.
Therefore, changing the measurement unit will have no
effect on the bar graph display.
2. Press MAX / MIN to toggle between current / MAX
wind speed and current / MIN wind chill displays.
The timestamp of when maximum wind speed was
recorded is displayed accordingly in the Clock Area.
UV INDEX
To clear minimum wind chill reading / maximum wind
speed reading:
The UV index levels are as follows:
1. Press SELECT to navigate to the Wind Speed / Wind
UV INDEX
0-2
DANGER LEVEL
Low
ICON
Direction / Wind Chill Area.
Area.
will show next to the
3-5
Moderate
High
2. Press MAX / MIN repeatedly until minimum wind
chill reading or maximum wind speed reading is
displayed.
6-7
8-10
Very high
Extremely high
3. Press and hold MAX / MIN to clear the readings.
11 and above
NOTE The wind chill factor is based on the combined
effects of temperature and wind speed. Displayed wind
chill is calculated solely from Channel 1 sensor.
To view the maximum UV reading:
1. Press SELECT to navigate to the UVI / Barometer /
Rainfall Area. will show next to the Area.
2. Press MODE repeatedly to select UV display.
3. Press MAX / MIN to toggle between current / MAX
UV index display.
UVI / BAROMETER / RAINFALL
The weather station works with one UV sensor and
one rain gauge. The station is capable of storing and
displaying the hourly history data for the last 10 hours
of UV index, and 24 hours of rainfall and barometric
pressure readings.
The timestamp of when maximum UV was recorded is
displayed accordingly in the Clock Area.
To clear maximum UV reading:
1. Press SELECT to navigate to the UVI / Barometer /
UVI
BAROMETER
RAINFALL
Rainfall Area.
will show next to the Area.
2. Press MODE repeatedly to select UV display.
3. Press and hold MAX / MIN to clear the readings.
BAROMETER
To set the altitude level compensation for the
Barometer readings:
The bar chart display shows the current and historical
data for the UV index, barometric pressure and rainfall
readings.
1. Press SELECT to navigate to the UVI / Barometer /
Rainfall Area.
will show next to the Area.
2. Press MODE repeatedly to select Barometric
display.
NOTE The number shown in the horizontal axis (Hr)
indicates how long ago each measurement was taken (e.g.
3 hours ago, 6 hours ago, etc.). The bar represents the
measurement taken for that specific 1 hour period. E.g., if it
is 10:30 pm now, the bar plotted directly above -1 shows the
reading recorded from 9 to 10 pm and -6 shows the reading
recorded earlier in the evening, between 4pm-5pm.
3. Press and hold MODE to enter the altitude setting.
4. Press UP / DOWN to increase / decrease the setting
value.
5. Press MODE to confirm the setting.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
RAINFALL
SPECIFICATIONS
BASE STATION
To view the recorded rainfall of the current hour or
last 24 hours:
Dimensions
(L x W x H)
180mm x 110mm x 47mm
(7.1 x 4.3 x 1.9 inches)
1. Press SELECT to navigate to the UVI / Barometer /
Rainfall Area.
will show next to the Area.
Weight
286g (10 ounces) without
battery
2. Press MODE repeatedly to select Rainfall display.
3. Press MAX / MIN repeatedly to toggle between
current hour or past 24 hour rainfall.
Battery
6V adaptor; 4 x UM-3 (AA) 1.5V
INDOOR BAROMETER
UPLOAD DATA TO PC SOFTWARE
Barometer unit
Measuring range
Accuracy
mb, inHg and mmHg
NOTE The software must be downloaded and installed
before data can be uploaded (refer to Installation
Guide).
700 – 1050mb/hPa
+/- 10 mb/hPa
NOTE The USB is only used for uploading data. It cannot
be used for charging battery power.
Altitude setting
Sea level
User setting for compensation
1. After successful installation, double click on
desktop shortcut.
Weather display
Memory
Sunny, Partly Cloudy, Cloudy,
Rainy and Snowy
2. Click Display in Oregon Scientific Weather Station
dialogue box.
Historical data and bar chart for
last 24hrs
3. You will be prompted to select model number. Please
select your model in the drop-down list and refer to
the image next to your selection to confirm it is the
correct model.
INDOOR TEMPERATURE
Temp. unit
°C / °F
Displayed range
Operating range
Accuracy
0°C to 50°C (32°F to 122°F)
-30°C to 60°C (-4°F to 140°F)
3
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
Memory
Current, Min and Max temp.
Dew Point w/ Min and Max
INDOOR RELATIVE HUMIDITY
Displayed range
Operating range
Accuracy
2% to 98%
4. Plug one end of the USB cable into the base station’s
USB port and the other end into the PC’s USB port.
25% to 90%
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Main unit will show
.
5. Uploading will start immediately.
Memory
Current, Min and Max
NOTE This product should be supplied by an identical
USB port complying with the requirements of Limited
Power Source.
RADIO-CONTROLLED / ATOMIC CLOCK
To learn more about how to utilize the functions available
on the software, please refer to PC Software Manual,
downloadable from:
Synchronization
Clock display
Hour format
Calendar
Auto or disabled
HH:MM:SS
12hr AM/PM or 24hr
DD/MM or MM/DD
(E, D, F, I, S, R)
Click on
PC Software Manual.
Weekday in 6
languages
BACKLIGHT
Press LIGHT to activate the backlight for 5 seconds.
REMOTE WIND SENSOR UNIT
Dimensions
(L x W x H)
178 x 76 x 214 mm
(7 x 3 x 8.4 inches)
RESET
Press RESET to return to the default settings.
Weight
100 g (3.53 ounces) without
battery
Wind speed unit
Speed accuracy
m/s, kph, mph, knots
2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy
16 positions
Transmission of
Approx. every 56 seconds
wind speed signal
9
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Placement of this product on certain types of wood
may result in damage to its finish for which Oregon
Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.
Memory
Battery
Max wind speed
2 x UM-3 (AA) 1.5V batteries
OUTDOOR TEMPERATURE / HUMIDITY UNIT
•
•
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Dimensions
(L x W x H)
92 x 60 x 20 mm
(3.6 x 2.4 x 0.79 in)
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
Weight
62 g (2.22oz) without battery
5% to 95%
Humidity range
Humidity accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
•
Please note that some units are equipped with a
battery safety strip. Remove the strip from the battery
compartment before first use.
Temp. unit
°C / °F
NOTE The technical specifications for this product and
the contents of the user manual are subject to change
without notice.
Temperature
outdoor range
-30°C to 60°C (-22°F to 140°F)
Temperature
accuracy
-20°C to 0°C:
+/- 2.0°C (+/- 4.0°F)
0°C to 40°C:
+/- 1.0°C (+/- 2.0°F)
40°C to 50°C:
NOTE Features and accessories will not be available
in all countries. For more information, please contact
your local retailer.
+/- 2.0°C (+/- 4.0°F)
50°C to 60°C:
+/- 3.0°C (+/- 6.0°F)
ABOUT OREGON SCIENTIFIC
more about Oregon Scientific products.
RF frequency
Range
433 MHz
If you’re in the US and would like to contact our
Customer Care department directly, please visit: www2.
oregonscientific.com/service/support.asp
Up to 100 meters (328 feet)
with no obstructions
Transmission
Channel no.
Batteries
Approx. every 102 seconds
For international inquiries, please visit: www2.
oregonscientific.com/about/international.asp
3
2 x UM-4 (AAA) 1.5V
EU DECLARATION OF CONFORMITY
REMOTE RAIN GAUGE
Hereby, Oregon Scientific, declares that this Wireless
Pro Weather Station with USB upload (Model: WMR88 /
WMR88A)isincompliancewiththeessentialrequirements
and other relevant provisions of Directive 1999/5/EC. A
copy of the signed and dated Declaration of Conformity is
available on request via our Oregon Scientific Customer
Service.
Dimensions
(L x W x H)
114 x 114 x 145 mm
(4.5 x 4.5 x 5.7 inches)
241 g (8.5 oz) without battery
Mm and in
Weight
Rainfall unit
Range
0 mm – 9999 mm
Accuracy
< 15 mm: +/- 1 mm
15 mm to 9999 mm: +/- 7%
Memory
Past 24hrs, hourly from last
memory reset
Battery
2 x UM-3 (AA) 1.5V
COUNTRIES RTTE APPROVAL COMPLIED
PRECAUTIONS
All EU countries, Switzerland CH
•
•
•
•
•
•
•
•
Do not subject the unit to excessive force, shock,
dust, temperature or humidity.
und Norwegen
N
Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit’s internal components.
This invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images shown in this manual may differ from the
actual display.
When disposing of this product, ensure it is collected
separately for special treatment and not as household
waste.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
|