MANUALLY SET CLOCK
GETTING STARTED
Weight
62 g (2.22 ounces)
30 m (98 ft) unobstructed
-20°C to 60°C
To set the clock manually, disable the signal reception
first.
Transmission range
INSERT BATTERIES
Temperature range
Power
1. Remove the battery compartment.
2. Insert the batteries, matching the polarities.
3. Press RESET after each battery change.
(-4°F to 140°F)
1. Press and hold MODE.
1 x UM-3 (AA) 1.5 V batteries
2. Press
or
to change the settings.
Indoor and Outdoor Thermometer with
Atomic Time
3. Press MODE to confirm.
ABOUT OREGON SCIENTIFIC
4. The settings order is: time zone, 12/24 hr format, hour,
minute, year, calendar mode (day – month / month
– day), month, day and language.
MEANING
LOCATION
Clock / alarm
Model: RMR202A
more about Oregon Scientific products. If you’re in the US
and would like to contact our Customer Care department
directly, please visit: www2.oregonscientific.com/service/
support
Main unit batteries
low
Select the time zone: (P) Pacific, (E) Eastern, (C) Central
or (M) Mountain.
Outdoor temperature
and humidity area
USER MANUAL
Sensor batteries low
NOTE The language options are English (E), German (D),
French (F), Italian (I), and Spanish (S).
OR
EN
Call 1-800-853-8883.
To select display mode:
REMOTE SENSOR
OVERVIEW
FRONT VIEW
For international inquiries, please visit: www2.
oregonscientific.com/about/international
Press MODE to choose between clock with seconds /
weekday / calendar.
The main unit can collect data from up to 3 sensors.
To set up the sensor:
FCC STATEMENT
1. Open the battery compartment (see FIG 3).
2. Select a channel then press RESET.
3. Close the battery door.
TEMPERATURE AND HUMIDITY
To toggle temperature unit:
Press °C / °F.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This
device must accept any interference received, including
interference that may cause undesired operation.
4. Place the sensor within 30 m (98 ft) of the main unit
using the table stand or wall mount.
��
To auto-scan between sensors:
Press and hold
for 3 seconds.
+ MEM to display each sensor’s data
��
TIP Ideal placements for the sensor would be in any location
on the exterior of the home at a height of not more than 5 ft and
which can shield it from direct sunlight or wet conditions for an
accurate reading.
WARNING Changes or modifications not expressly
approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
To end press
.
��
��
To toggle between current, minimum and maximum
records for the selected sensor:
��
��
NOTE This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation.
Press MEM repeatedly.
��
��
To clear the records:
Press and hold MEM.
��
ICE WARNING
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
��
If the channel 1 sensor falls between 3°C to
1. Remote sensor reception indicator
2. Clock signal reception indicator
3. Indoor temperature
-2 °C (37°F to 28°F), LED indicator will flash, and will stop
flashing once the temperature is out of this range.
5ft
is no guarantee that interference will not occur in
a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or
more of the following measures:
RESET
4. MODE: Change settings / display
Press RESET to return to the default settings.
5.
/
:
Increase
/
decrease setting; activate
/
PRECAUTIONS
deactivate clock reception signal
•
Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
6. Outdoor temperature
7. Time zone
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and
receiver.
•
•
•
•
•
•
•
•
Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
NOTE Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures below
freezing.
8. Clock with weekday
•
•
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
9. MEM: View current, maximum and minimum
Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
temperature / humidity
SENSOR DATA TRANSMISSION
To search for a sensor:
Consult the dealer or an experienced radio / TV technician
for help.
10.Ice alert LED indicator
Do not clean the unit with abrasive or corrosive
materials.
BACK VIEW
Press and hold
+ MODE.
DECLARATION OF CONFORMITY
Do not tamper with the unit’s internal components. This
invalidates the warranty.
The sensor reception icon in the remote sensor area
shows the status:
The following information is not to be used as contact for
support or sales. Please call our customer service number
the warranty card for this product) for all inquiries instead.
Only use fresh batteries. Do not mix new and old
batteries.
ICON
DESCRIPTION
Images shown in this manual may differ from the actual
display.
Main unit is searching for
sensor(s).
We
When disposing of this product, ensure it is collected
separately for special treatment.
Name:
Oregon Scientific, Inc.
19861 SW 95th Ave.,Tualatin,
Oregon 97062 USA
Placement of this product on certain types of wood
may result in damage to its finish for which Oregon
Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.
Address:
A
channel has been
found.
Telephone No.: 1-800-853-8883
•
•
The contents of this manual may not be reproduced
without the permission of the manufacturer.
The sensor cannot be
found.
declare that the product
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
Product No.:
RMR202A
Product Name: Indoor and Outdoor Thermometer with
Atomic Time
TIP The transmission range may vary depending on many
factors. You may need to experiment with various locations
to get the best results.
•
Please note that some units are equipped with
a
Manufacturer:
Address:
IDT Technology Limited
battery safety strip. Remove the strip from the battery
compartment before first use.
1. °C / °F: Select temperature unit
Block C, 9/F, Kaiser Estate,Phase 1,41
Man Yue St., Hung Hom, Kowloon,
2. RESET: Reset unit to default settings
CLOCK
Hong Kong
NOTE The technical specifications for this product and the
contents of the user manual are subject to change without
notice.
REMOTE SENSOR
CLOCK RECEPTION
This product is designed to synchronize its clock
automatically with WWVB-60 signal, within 3200km (2000
miles) of Fort Collins Colorado.
is in conformity with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: 1) This device
may not cause harmful interference. 2) This device must
accept any interference received, including interference
that may cause undesired operation.
SPECIFICATIONS
To enable / disable signal reception:
TYPE
DESCRIPTION
Press and hold
reception.
to enable or
to disable signal
MAIN UNIT
77 x 41.5 x 116.5mm
(3.03 x 1.63 x 4.59 in)
241 g (8.5 oz)
without battery
-5°C to 50°C
L x W x H
NOTE Reception takes 2-10 minutes. If the signal is weak,
it can take up to 24 hours to get a valid signal.If signal
reception is unsuccessful, place your unit next to a window,
Weight
press and hold
to force another signal search.
Temperature range
(23°F to 122°F)
0.1°C (0.2°F)
Clock signal reception indicator:
Resolution
STRONG
SIGNAL
WEAK
Signal frequency
Humidity range
Humidity resolution
Power
433 MHz
1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole
NO SIGNAL
SIGNAL
25% - 95%
1%
2 x UM-4 (AAA) 1.5 V batteries
REMOTE UNIT (THN132N)
96 x 50 x 22 mm
(3.78 x 1.97 x 0.87 in)
5. CHANNEL switch
L x W x H
P/N:086XXXXX-XX
Download from Www.Somanuals.com. All Manuals Search And Download.
RMR202A.indd
1
2007.6.21 9:12:49 AM
|