2. Weather forecast
To enable and force a signal search:
3. Preset radio station number
4. AM / FM station; radio frequency in MHz or KHz and
volume level
Press and hold TUNING / SET
for 2 seconds.
To disable the signal reception:
5. Radio-controlled clock reception icon
6. 12-hour clock
Press and hold TUNING / SET
for 2 seconds.
flashes when it is searching for the atomic clock
signal and disappears when it is disabled.
7. Indoor temperature display icon
8. Channel number and sensor reception status
9. Sensor low battery warning
10. Outdoor temperature reading
11. Maximum / minimum outdoor temperature reading
12. Main unit low battery warning
13. Indoor temperature reading
14. Maximum / minimum indoor temperature reading
15. Sleep function is activated
16. Alarm is displayed
Touch-Control AM/FM Atomic Weather
Clock with Dual Alarm
CLOCK
Model: BARM699A
For best results:
To manually set the clock make sure the clock signal
reception is disabled.
Place the sensor out of direct sunlight and
moisture.
•
USER MANUAL
INTRODUCTION
Thank you for selecting the Oregon ScientificTM Touch-
Control AM/FM Atomic Weather Clock with Dual
Alarm (BARM699A). The main unit can support up
to 3 sensors. To purchase additional sensors, please
contact your local retailer.
Do not place the sensor more than 30 meters (100
feet) from the main (indoor) unit.
•
To manually set the clock:
1. Press and hold CLOCK for 2 seconds.
2. Press TUNING / SET
settings.
3. Press CLOCK to confirm.
4. The setting sequence is: US time zone, 12 / 24
hour format, hour, minute, year, day / month format,
month, day, and display language.
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls,
and furniture.
•
/
to change the
17. Beep alarm is set
18. Radio alarm is set
19. US time zone, weekday or seconds
20. Time, alarm and date
Place the sensor in a location with a clear view to
the sky, away from metallic or electronic objects.
•
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may
affect battery performance and signal transmission.
•
NOTE Please keep this manual handy as you use
your new product. It contains practical step-by-step
instructions, as well as technical specifications and
warnings you should know about.
REMOTE SENSOR
NOTE The US time zone options are Pacific (PA),
Mountain (MO), Central (CE) and Eastern (EA).
The transmission range may vary depending on many
factors. You may need to experiment with various
locations to get the best results.
1. LED status indicator:
Blinks red during data
1
NOTE The language options are (E) English, (F)
transmission
2. Ventilation duct
French, (D) German, (I) Italian, and (S) Spanish.
OVERVIEW
FRONT VIEW
Standard Alkaline batteries contain significant
amounts of water. Because of this they will freeze
in low temperatures of approximately -12°C (10°F).
2
To switch the clock display:
Press CLOCK to toggle between:
1
1
Disposable Lithium batteries have
a
much lower
Clock with seconds
Clock with weekday
Calendar
•
3
threshold for temperature with an estimated freezing
range of below -30°C (-22°F).
•
5
•
1. Wall mount
2. Battery compartment
3. Battery door
4. Table stand
2
3
6
Wireless ranges can be impacted by a variety of factors
such as extremely cold temperatures. Extreme cold
may temporarily reduce the effective range between the
sensor and the base station. If the unit’s performance
fails due to low temperature, the unit will resume proper
functioning as the temperature rises to within the
normal temperature range (i.e. no permanent damage
will occur to the unit due to low temperatures).
ALARM
4
To set the alarm:
1. Press ALARM to view the alarm.
the display.
will show on
7
5. CHANNEL switch
2
5
2. Press and hold ALARM for 2 seconds.
4
3. Press TUNING / SET
/
to change the hour,
minute, beep or radio alarm. If you select the radio
alarm, press AM / FM and STATION to select the
band and station respectively.
GETTING STARTED
POWER
SENSOR DATA TRANSMISSION
The reception icon shown in the outdoor temperature
area shows the status.
1. SLEEP / SNOOZE: Activate snooze; set the sleep
timer
2. RADIO ON / OFF: Turn radio ON / OFF
3. STATION:Toggle between 16 preset radio channels;
save a channel
4. VOLUME
5. CLOCK: Change setting / display
6. AM / FM: Toggle between AM and FM
7. TUNING / SET
4. Press ALARM to confirm.
Plug adapter into main unit.
To activate or deactivate the alarm:
Press ALARM when in the alarm display.
or
ICON
DESCRIPTION
appears when the alarm is set.
Main unit is searching for
the sensor(s)
A channel has been found
and signal is being
received
/
: Increase / decrease volume
To silence the alarm:
Press SNOOZE to silence it for 8 minutes.
•
/
: Increase / decrease
OR
setting; activate / deactivate clock reception signal;
change radio frequency
Press any key except SNOOZE to turn the alarm off
and activate it again after 24 hours.
•
and “- -“
(Outdoor temperature
area)
The sensor cannot be found.
Search for the sensor or
check the battery
NOTE This product may malfunction when radio
interference appears on the AC power line. The unit will
revert to normal operation when interference stops.
BACK VIEW
NOTE
or
flashes when snooze is activated.
To search for a sensor:
WEATHER FORECAST
Simultaneously, press and hold MEM and CHANNEL
for 2 seconds.
1
2
4
NOTE Install the remote sensor battery and plug in the
main unit. Press RESET after each battery change. Do
not use rechargeable batteries. It is recommended that
you use alkaline batteries with this product for longer
performance.
This product forecasts the weather for the next 12 to 24
hours within a 19-31 mile (30-50 km) radius, with 70 to
75 percent accuracy.
NOTE The sensor LED flashes when data is being
sent to the main unit. If the sensor signal is still not
found, check the battery, obstructions, and remote unit
location.
SUNNY PARTLY CLOUDY CLOUDY RAINY
shows when battery is low.
LIGHT TOUCH KEY
5
6
UNIT
Main
Remote
LOCATION
Indoor temperature area
Outdoor temperature area
3
TEMPERATURE
The touch keys used in this product have a key lock
function that prevents accidental changes to user
settings. When the clock keys have not been used in
the last minute, the key lock function is automatically
activated. Press any key once to disable the key lock
function and then operate the clock as usual.
To change the temperature measurement unit:
Press °C / °F on the bottom of the unit.
1. MEMORY: View current, maximum and minimum
temperature
REMOTE SENSOR
2. CHANNEL: Switch remote sensor display
3. Adapter socket
4. ALARM: View alarm status; set alarm
5. °C / °F: Select temperature unit °C / °F
6. RESET: Reset unit to default settings
To view outdoor sensor(s) temperature readings:
Press CHANNEL.
The sensor collects temperature readings approx. every
40 seconds and sends them to the main unit. The main
unit can collect data from up to 3 sensors.
shows which remote sensor’s data you are
viewing.
•
CLOCK RECEPTION
is permanently displayed in the indoor
temperature area.
This product is designed to synchronize its date and
time automatically once it is within range of the WWVB-
60 signal from the atomic clock in Boulder, Colorado.
To set up the sensor:
1. Slide open the battery door.
2. Insert the battery, matching the polarity (+ / -).
3. Select a channel. Make sure you use a different
channel for each sensor.
•
LCD
To auto-scan between sensors:
Press and hold CHANNEL for 2 seconds. Each sensor’s
data is displayed for 3 seconds.
7
8
9
The sensor collects the radio signals whenever it is
within 3219 km (2000 miles) of a signal.
1
10
11
2
To end auto-scan:
Press CHANNEL or MEMORY.
NOTE Initial reception takes 2-10 minutes for first set
up or when RESET is pressed. Once complete, the
reception icon will stop blinking. If the signal is weak, it
can take up to 24 hours to get a valid signal.
12
13
14
15
16
17
3
4
5
To toggle between current, minimum and maximum
records for the selected sensor:
Press MEMORY repeatedly.
6
18
RECEPTION SIGNAL
19
STRONG
WEAK
NO SIGNAL
To clear the records:
4. Close the battery compartment.
5. Secure the sensor in the desired location using the
wall mount or table stand.
20
Select the channel to clear the memory, then press and
hold MEMORY for 2 seconds.
1. Ice warning
BARM699A_EN_R5.indd
1
2/17/06 2:04:50 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
|