POLERMO Projection Clock
with Motion Alert
Model: RMR939PA / MSR939A
USER MANUAL
RMR939PA English Cover R5
1
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Notices .................................................................... 23
Statement of Responsibility ................................. 23
About Oregon Scientific ........................................ 23
FCC Statement ....................................................... 24
Declaration of Conformity .................................... 24
INTRODUCTION
Thank you for selecting the Oregon ScientificTM
POLERMO Projection Clock with Motion Alert. This
device is designed to give you many years of reliable
service, including the following conveniences:
•
•
US Atomic Calendar Clock
Optional Wireless Vibration Alarm with 8-Minute
Snooze Function (Wake-Up Vibrating Alarm
VR101A can be purchased separately)
•
•
•
•
•
•
•
•
•
Sleep Function with 6 Soothing Sounds
5 Alarm Melodies with 2 Volume Levels
2-Minute Dual Alarm with 8-Minute Snooze Function
Time / Alarm Status Projection Unit
Security Alarm / Motion Sensor Unit
Indoor Temperature Display
Day of the Week in 1 of 5 Languages
Time Zone Hour Offset Function
Backlight for Clock
Keep this manual handy as you use your new product.
It contains practical step-by-step instructions, as well
as technical specifications and warnings you should
know.
2
RMR939PA English R5
2
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT OVERVIEW
FRONT VIEW
1
2
1. SOUND / SLEEP button
•
•
Press to turn the soothing sound ON.
Press to wrap around the sleep timer setting as
follows: 0
minutes.
120
90
60
30
15
3
0
•
Press and hold for 2 seconds to choose 1 of
6 soothing sounds.
6
7
2. SNOOZE / LIGHT button
4
5
•
•
Press to activate the 8-minute snooze function.
Press and hold for 2 seconds to turn snooze OFF
and reset the alarm for the next day.
8
•
Press to activate the backlight and projection for
5 seconds.
3. LCD display
4. CLOCK ALARM button
•
Press to toggle between alarm 1 and alarm 2 -
ON / OFF.
•
Press and hold for 2 seconds to enter the Alarm
Time Setting Mode.
5. MOTION ALARM button
•
Press to enter the Motion Alarm Mode; press
again to toggle between motion alarm ON / OFF.
3
RMR939PA English R5
3
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Press and hold for 2 seconds to enter:
-
-
Motion Sensor Code.
MotionAlarm Setting Mode for motion alarm
period and alarm type.
6. Projector
Projects time and alarm status.
7. CLOCK button
•
Press to toggle between the following display
modes:
-
-
-
Clock with seconds and calendar.
Clock with weekday and calendar.
Clock with time zone hour offset and calendar.
•
Press and hold for 2 seconds to enter the
Clock Setting Mode - US time zone hour offset,
12- / 24-hour format, hour, minute, year, MM / DD
or DD / MM format, month, day and day of the
week language.
8.
UP /
DOWN button
•
•
Press to increase or decrease a setting.
Press and hold for 2 seconds to activate or
deactivate atomic clock.
•
Press to increase or decrease the soothing sound
volume.
4
RMR939PA English R5
4
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
BACK VIEW
1. Projector FOCUS knob
Twist to focus the projected image.
2. Projector IMAGE ROTATION knob
•
1
•
Twist to get the best viewing angle of the projected
image.
6
3. PROJECTION ON switch
•
Slide to ON for continuous image projection when
the AC power is connected.
2
3
4
4. Projector 180° ROTATION button
Press to rotate the image upside down.
5
•
7
8
5. 6V AC / DC Power Socket
6. Battery Compartment (cover on)
•
Uses 4 x UM-3 / AA 1.5V batteries.
7. RESET hole
Insert a thin blunt instrument to return all values
to the default settings.
8. °C / °F switch
Press to select between °C / °F display format.
•
•
5
RMR939PA English R5
5
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
LCD DISPLAY
1. SOUND
1
2
10
11
•
Appears when the sleep function is activated.
3
4
2. Battery Low icon
5
6
•
Appears when the clock batteries are low or, no
batteries are installed and only the AC adaptor is
connected.
12
13
7
8
3. Time
14
15
•
HH / MM, 12- / 24-Hour, AM / PM.
16
4. ZONE
17
18
19
9
•
Appears when you are in the Time and Zone Hour
Offset display.
5. Channel 1 / 2
Ch.1 or Ch.2 will appear when the related motion
sensor is activated.
•
6. Motion Alarm ON icon
7. Calendar
•
DD / MM / YY or MM / DD / YY.
8. Temperature
°C / °F.
9. Atomic Clock Signal Reception icon
•
•
Shows the strength of the reception signal.
6
RMR939PA English R5
6
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
10. MIN
•
Appears when the sleep function is activated.
11. Time Zone Hour Offset / Day of the Week
•
Offsets the atomic clock time setting when you
are in a different time zone (+ / -23 hours).
•
Name of day available in 1 of 5 languages.
12. START
•
Start time for the motion sensor to be activated.
13. Alarm 1
•
Indicator to show this is alarm 1.
14. Alarm 1 / 2 Time
•
Shows alarm times / AM or PM.
15. Melody Alarm icon
•
Shows when the clock alarm is set.
16. Vibration Alarm icon (Wake-Up Vibration Alarm -
optional item)
•
Appears on the display when the vibrating alarm
has been set.
17. Alarm 2
•
Indicator to show this is alarm 2.
18. STOP
•
Stop time for the motion sensor.
19. Motion Alarm Settings icon
7
RMR939PA English R5
7
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
REMOTE MOTION SENSOR (MSR939A) - FRONT VIEW
1. Rotary Motion Sensor
•
Detects motion and activates both alarms on the
remote motion sensor and main clock units in
accordance with the settings used.
1
•
Twist the knob to direct the sensor to the position
you want.
2. ALARM SOUND ON / OFF switch
•
Slide switch to ON - the sensor will sound the
alarm if it detects movement.
•
Slide switch to OFF - the alarm sound function
will be turned off.
5
2
3
3. POWER ON / OFF
•
Slide to turn the motion sensor ON or OFF.
4. 4.5V Adaptor Socket (adaptor not included)
5. Motion Alarm Speaker
4
6. LED Indicator
6
8
RMR939PA English R5
8
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
REMOTE MOTION SENSOR (MSR939A) - BACK VIEW
1. Wall Mount
2. Battery Compartment (cover on)
•
Uses 3 x UM-3 / AA 1.5V batteries.
3. CHANNEL 1 / 2
•
Slide to select either Channel 1 or Channel 2.
4. CODE switch
1
2
•
Slide to change the Code.
5. RESET hole
•
Insert a thin blunt instrument to return all values
to the default settings.
3
4
5
9
RMR939PA English R5
9
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Keep your product away from hot, humid conditions
or strong sunlight.
SAFETY AND CARE
SAFETY PRECAUTIONS
Every effort has been made to ensure the highest
standards of reliability for your clock with remote
motion sensor. However, if something does go
wrong, please do not try to repair it yourself - consult
your supplier.
Please observe the following safety precautions when
setting up and using this product.
•
LCD panel - The LCD panel is made of glass, and
may break if the unit is dropped.
•
Do not use your product outdoors in the rain, or
handle it with wet hands - water can damage
electrical equipment.
•
Heat sources - Keep the product away from heat
sources, such as radiators, stoves, heaters, and
other heat-generating products.
•
•
Water and moisture - Do not use the product in or
near water or in high moisture areas, such as a
bathroom.
GETTING STARTED
PACKAGE CONTENTS
Power source - The product may be susceptible to
power surges. It should be unplugged during severe
storms or whenever you will be away for a long time.
Only use the type of power source specified in this
manual. Do not overload power strips and extension
cords, as this can cause a fire hazard.
When you unpack your clock with remote motion sensor,
make sure you keep all the packing materials in a safe
place, in case you need to later transport the device or
return it for servicing.
In the box, you will find:
CARING FOR THIS PRODUCT
•
•
•
•
•
Clock Unit
To ensure you receive the maximum benefit from using
this product, please observe the following guidelines.
Remote Motion Sensor
•
Do not clean any part of the product with benzene,
thinner or other solvent chemicals - this may cause
permanent damage that is not covered by the
guarantee. When necessary, clean it with a damp
cloth.
4 x UM-3 / AA 1.5V Batteries for the Clock
6V AC / DC Adaptor for the Clock
3 x UM-3 / AA 1.5V Batteries for the Remote Motion
Sensor
10
RMR939PA English R5
10
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
To install the clock batteries:
BATTERIES
The clock uses:
•
4 x UM-3 / AA 1.5V batteries.
The motion sensor uses:
3 x UM-3 / AA 1.5V batteries.
•
The optional wake-up vibration alarm VR101A
(not included in the package) uses:
•
2 x UM-3 / AA 1.5V batteries.
To install the motion sensor batteries:
NOTE
It is recommended that you use alkaline
batteries with this product for longer performance.
To install the batteries, simply insert them making sure
they match the correct polarities (+ and -). For best
results, install batteries in the motion sensor before the
clock. Press RESET after each battery change.
NOTE Do not use rechargeable batteries for the clock
or remote motion sensor.
11
RMR939PA English R5
11
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
The remote sensor jack can be inserted into the socket
as shown below:
shows on the clock display when batteries are low
or when there are no batteries installed and only the
adaptor is connected.
The LED indicator on the motion sensor and vibration
alarm will flash in red when the batteries are low.
AC ADAPTOR
The clock / projector and the motion sensor use 6V and
4.5V AC / DC adaptors respectively. (Adaptor for the
motion sensor is not included.)
The clock AC adaptor socket is found on the bottom of
the clock. The jack can be inserted into the socket as
shown below:
NOTE
The motion sensor has a Power ON / OFF
switch to help conserve energy. Use the AC adaptor
when using the motion sensor for long periods of time.
The batteries are a good power source for back-up use.
ABOUT ATOMIC CLOCK RECEPTION
This clock can automatically synchronize the date and
time with an official time-keeping organization in
Boulder, Colorado. The unit can pick up an atomic
clock signal when it is within 932 miles (1500km) of
these locations. For more information on the Atomic
12
RMR939PA English R5
12
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
To turn the atomic clock signal reception OFF:
NOTE
For best results, place the clock away from metal
or electrical objects, and near a window with a clear view
to the sky.
•
•
Press and hold the button for 2 seconds.
The atomic clock reception icon will disappear from
the display.
TURNING THE ATOMIC CLOCK SIGNAL ON / OFF
To turn the atomic clock signal reception ON:
CLOCK / CALENDAR
•
•
Press and hold the button for 2 seconds.
CLOCK / CALENDAR DISPLAY
The atomic clock reception icon will appear and flash
on the display to indicate it is searching for the atomic
clock signal.
There are 3 types of clock display:
Calendar /
Clock / Sec
Calendar /
Clock / Day
Calendar /
Clock / Offset
Once batteries have been installed in the clock, the
reception icon will flash to indicate it is searching for a
signal.
When the reception signal has been received the
reception icon will show the signal strength by displaying
between 0 and 3 waves:
Press the CLOCK button to toggle between the 3 types
of display.
Strong Signal
Weak Signal
No Signal
13
RMR939PA English R5
13
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Press CLOCK ALARM or MOTION ALARM to exit
SETTING THE CLOCK / CALENDAR
the Clock Setting Mode.
Before you can manually set the clock and calendar,
you must specify the current time zone you live in and
the time format (12- or 24-hour) as follows:
You can select 1 of the 5 following languages:
SYMBOL
LANGUAGE
English
1. Press and hold the CLOCK button for 2 seconds.
The time zone offset hour digits will flash. The default
setting will be -8 which stands for Pacific time. Select
the following for different US time zones:
German
French
-7 : Mountain time
-6 : Central time
-5 : Eastern time
Italian
Spanish
BACKLIGHT
Press SNOOZE / LIGHT to activate the backlight for
5 seconds.
TEMPERATURE
2. Enter the value by pressing the or buttons.
To choose between °C / °F, press the °C / °F button to
select the setting you want.
3. Confirm the entry by pressing the CLOCK button.
The 12- or 24-hour display format will flash.
4. Repeat (2) and confirm the entry by pressing the
CLOCK button.
5. Repeat the above procedures to set the hour, minute,
year, MM / DD or DD / MM format, month, day and
day of the week language.
14
RMR939PA English R5
14
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
ACTIVATING / DEACTIVATING THE ALARM(S)
ALARM
•
Press the CLOCK ALARM button to toggle between
alarm 1 and alarm 2 ON / OFF.
ALARM DISPLAY
The melody and vibration alarm icons indicate the daily
alarm settings. Any disabled alarm will show no melody
or vibration alarm icons.
•
When the melody or vibration alarm icons appear
on the display the alarm is activated. When the icons
do not appear the alarm is deactivated.
ALARM SOUND
When activated, the alarm icon flashes, the backlight
will come on for 8 seconds and the alarm melody or
beep sound will play. If no key is pressed the alarm will
play for 2 minutes.
Alarm 2 (Wake-Up) Alarm 2 Melody
+ Wake-Up
Alarm 1 (Melody)
Alarm 2 Disabled
SETTING THE ALARM(S)
NOTE See "Setting theAlarm(s)" section to choose the
1. Press and hold CLOCK ALARM for 2 seconds to
alarm melody / beep alarm and / or the vibration alarm.
enter the Alarm Setting Mode.
2. Alarm 1 will start flashing. Use the
and
SNOOZE / TURNING THE ALARM OFF
buttons to toggle between alarm 1 and 2. Then press
CLOCK ALARM to select alarm 1 or 2. The hour
will start flashing.
To silence the alarm:
•
Press SNOOZE / LIGHT to silence it for 8 minutes.
The alarm 1 or alarm 2 icon will flash to show snooze
is enabled. Press and hold for 2 seconds to turn off
snooze.
3. Enter the value by pressing the or buttons.
4. Confirm the entry by pressing the CLOCK ALARM
button and move on to the next setting.
5. Repeat (3 and 4) to set alarm 1 / alarm 2 - minute,
melody alarm and / or vibration alarm (optional). If
the melody alarm is selected, repeat (3 and 4) to
select the melody / beep alarm sound and volume.
OR
•
Press any key except SNOOZE / LIGHT to mute the
alarm and activate it again in 24 hours.
6. The daily alarm will be on automatically after setting.
Press CLOCK at any time to exit theAlarm Setting Mode.
15
RMR939PA English R5
15
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE
If no button is pressed, the alarm will
SETTING THE MOTION ALARM
automatically silence after 2 minutes. It will then sound
again in 24 hours.
The motion alarm has a security / monitoring function,
whereby when the motion sensor detects movement, it
sets off the clock alarm for 5 minutes and the backlight
will turn on for 10 seconds. The clock will also show
which sensor has been activated - Ch.1 or Ch.2 will
appear in the top left hand corner of the display.
MOTION ALARM
MOTION ALARM SETTING DISPLAY
The motion sensor icon indicates the motion alarm
setting.
You can set the motion alarm to be activated over a set
period of time i.e. during night time, by entering values
next to the Start / Stop Hour in the process detailed
below. However, it is important that you set the Code on
the clock display to match the Code on the back of the
motion sensor(s) so that the items can interact with each
other. This process is also detailed below.
1
2
1. Press and hold MOTION ALARM for 2 seconds to
enter the Motion Alarm Setting Mode.
2. The Code will start flashing. Use the and buttons
to choose the same Code setting as that displayed
on the back of the motion sensor. Then press
MOTION ALARM to select your chosen option. The
start hour digits will start flashing.
1. Code icon
3. Enter the value by pressing the or buttons.
2. Motion Sensor icon
4. Confirm the entry by pressing the MOTION ALARM
button and move on to the next setting.
5. Repeat (3 and 4) to set the stop hour, beep / melody
and volume.
6. The motion alarm will be on automatically after setting.
16
RMR939PA English R5
16
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Press CLOCK or CLOCK ALARM at any time to exit
the Motion Alarm Setting Mode.
TURNING THE MOTION ALARM OFF
Press any button on the clock to turn the motion alarm
off. It will sound again when the remote motion sensor
unit detects a motion again.
SLEEP TIMER
2. Press the SOUND / SLEEP button to set the sleep
timer to turn off after 120 90 60 30 15
You can choose 1 of 6 soothing sounds to play for a set
time while you fall asleep:
or 0 minutes. When 0 minutes is selected the
soothing sound will automatically turn off after a few
seconds.
•
•
•
•
•
•
Bird
Wind
3. Use the or buttons to change the soothing sound
volume.
River
4. SOUND will flash on the LCD display to indicate that
Raindrop
Waterfall
Ocean Wave
the sleep timer is activated.
To select the soothing sound:
To set the sleep timer and soothing sound volume:
1. Press and hold the SOUND / SLEEP button for
2 seconds when the soothing sound is on. The
soothing sound number will flash.
1. Press the SOUND / SLEEP button once. The
soothing sound will turn on and the sleep timer will
display the last setting.
17
RMR939PA English R5
17
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE You can also press the SNOOZE / LIGHT button
to project the time and alarm status for 5 seconds.
MOTION SENSOR (MSR939A)
The motion sensor has a security / monitoring function.
It can set off your motion alarm on the clock for 5 minutes
and turn the backlight on for 10 seconds when it detects
movement.
2. Use the
or
buttons to change the type of
soothing sound.
Data can be collected from up to 2 sensors. Additional
sensor sold separately.
3. Press the SOUND / SLEEP button to confirm the
setting.
SETUP SENSOR
1. Slide the motion sensor battery door open.
PROJECTION UNIT
2. Insert the batteries, matching the polarity (+ and -)
as shown in the battery compartment.
The projection unit can display both time and alarm
status. To use this feature:
SWITCH
Channel
OPTION
Channel 1-2. If you are using more
than one sensor, select a different
channel for each sensor.
•
Slide the PROJECTION switch to ON to activate
continuous projection. However, this function will not
work unless the AC / DC adaptor is used.
•
•
Adjust the FOCUS knob to make the image clearer.
3. Set the channel by sliding the CHANNEL switch to
1 or 2. The switch is located in the battery
compartment.
Adjust the IMAGE ROTATION knob to rotate the
image clockwise or anti-clockwise.
•
Manually tilt the projection unit to position the image
or press the 180° ROTATION button to reverse the
image and turn it upside down.
4. Set the code by sliding the CODE switches to the
same setting as the Code on the clock display. This
enables the clock and motion sensor to interact with
each other.
18
RMR939PA English R5
18
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Press the RESET button. Close the motion sensor
You may need to experiment with various locations to
get the best results.
battery compartment.
6. Secure the sensor in the desired location using the
wall mount or table stand.
7. Twist the motion sensor knob to direct the sensor to
the position you want.
WAKE-UP VIBRATION ALARM - VR101A
(OPTIONAL)
8. Slide the POWER ON / OFF switch to turn the motion
The vibrating alarm receives a signal from the clock and
performs a wake-up function by vibrating. It is designed
to go under your pillow.
sensor ON or OFF.
9. Slide the ALARM SOUND ON / OFF switch to ON
to activate the alarm sound function. The motion
sensor alarm will now sound for 20 seconds if it
detects movement. Slide to OFF to deactivate this
function.
The device has a range of roughly 50 feet and has an
LED indicator to show data transmission and battery
level.
Once it has power, the motion sensor takes
2 minutes to warm up.
NOTE
The switch within the vibrating alarm can adjust to
alarm 1 or alarm 2, or both. Simply select the alarm time
on the clock unit when you want the vibrating alarm to
wake you up.
For best results:
•
Insert the batteries and select the channel before
you mount the sensor.
The vibrating alarm is powered by 2 x UM-3 /
AA 1.5V batteries (included). It is also compatible with
rechargeable batteries (not included).
NOTE
•
•
Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 98 feet
(30 meters) from the main (indoor) unit.
•
•
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls,
and furniture.
RESETTING THE CLOCK
Insert a thin blunt instrument into the hole below RESET
to return to the default settings.
Place the sensor in a location with a clear view to
the sky, away from metallic or electronic objects.
19
RMR939PA English R5
19
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Do not tamper with the internal components.
The default settings are:
Do not mix new and old batteries or batteries of
different types.
Clock Time:
12.00 PM
•
•
Do not use rechargeable batteries with this product.
Date:
1st January 2004
-8 (Pacific Time)
6.00 AM
Remove the batteries if storing this product for a long
period of time.
Time Offset:
Alarm 1 and 2 Time:
Alarm Melody:
Daily Alarms:
•
Do not scratch the LCD display.
#1 with low volume
Disabled
The technical specification of this product and
NOTE
contents of this user manual are subject to change
without notice. Images not drawn to scale.
Motion Alarm Start Time:
Motion Alarm Stop Time:
Motion Alarm:
12.00 AM
6.00 AM
Disabled
Display Setting:
12hr, MM / DD, °F
TROUBLESHOOTING
PROBLEM
SYMPTOM
REMEDY
WARNINGS
Clock time
is not
correctly
set.
No atomic
clock
signal
Place the clock far
away from PCs,
phones, and other
electronic equipment
and near a
This product is designed to give you years of service if
handled properly. Oregon Scientific will not be
responsible for any deviations in the usage of the device
from those specified in the user instructions or any
unapproved alterations or repairs of the product.
Observe the following guidelines:
reception.
windowsill. Wait for
at least 24 hours.
•
Never immerse the product in water. This can cause
electrical shock and damage the product.
No alarm.
Alarm does
not sound.
Turn on the alarm
setting.
•
Do not subject the product to extreme force, shock,
or fluctuations in temperature or humidity.
20
RMR939PA English R5
20
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
PROBLEM
SYMPTOM
REMEDY
PROBLEM
SYMPTOM
REMEDY
Operation
not normal.
Certain
functions
do not
Reset the clock and
the motion sensor.
Motion
Sensor.
Does not
activate the
motion
alarm on
the clock.
1. Adjust batteries /
AC adaptor.
2. Check POWER
ON / OFF switch is
set to ON.
perform.
Calendar.
Clock.
Strange
day.
Check it is set to
your own language.
3. Check the CODE
switch on the
motion sensor
matches the clock
code display.
Cannot
change
clock.
Disable the atomic
clock signal and set
manually.
Clock /
Calendar.
Cannot
auto-
synchronize
the clock.
1. Adjust batteries.
2. Press RESET on
the clock and
motion sensor.
TECHNICAL SPECIFICATIONS
Temperature. Shows
"LLL" or
Temperature is out of
range.
TYPE
DESCRIPTION
"HHH".
Main Unit Dimensions
L x W x H
6.34 x 1.18 x 4.06 inches
(161 x 30 x 103 mm)
Motion
Sensor.
Does not
give out
alarm
1. Adjust batteries /
AC adaptor.
2. Check POWER
ON / OFF switch
is set to ON.
Weight (without battery) 0.59 lbs (268 g)
sound.
Remote Motion Sensor Dimensions
L x W x H
3.46 x 1.69 x 4.41 inches
(88 x 43 x 112 mm)
3. Check ALARM
SOUND switch is
set to ON.
Weight (without battery) 0.31 lbs (140 g)
21
RMR939PA English R5
21
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
TYPE
DESCRIPTION
TYPE
DESCRIPTION
Temperature
Unit
Hour Format
Calendar
12hr AM / PM or 24hr
°F / °C
DD / MM or MM / DD,
user selectable. Weekday
selection in 5 languages
(E, D, F, I, S)
32°F to +122°F
(0°C to +50°C)
Operating Range
Indoor Range
23°F to +122°F
(-5°C to +50°C)
Alarm
Daily dual alarm
•
•
2-minute crescendo
8-minute snooze
Resolution
0.2°F (0.1°C)
Main Unit Atomic Frequency
Motion Alarm
Atomic Clock
WWVB60
Frequency System
•
Soundsfor5minutes
Synchronization
RF Frequency
Auto or disabled
433 MHz
Power
Main Unit
4 x UM-3 (AA) 1.5V
batteries or 6V AC
adaptor
Reception Range
98 feet (30 meters) with
no obstructions
Remote Motion
Sensor Unit
3 x UM-3 (AA) 1.5V
batteries or 4.5V AC
adaptor (adaptor not
included)
Remote Unit
Motion Sensor
Coverage Distance
Approx. 16 feet
(5 meters)
Motion Sensor Warm-
Up Time
Approx. 2 minutes after
power-on
Adaptor output current
>=50mA
Main Unit Display
NOTE It is recommended that you use alkaline
batteries with this product for longer performance.
Clock
HH:MM:SS
HH:MM:Day of week
HH:MM:Time zone
hour offset
NOTE Design and specifications are subject to change
without notice.
22
RMR939PA English R5
22
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTICES
ABOUT OREGON SCIENTIFIC
STATEMENT OF RESPONSIBILITY
more about Oregon Scientific products such as digital
cameras; MP3 players; children's electronic learning
products and games; projection clocks; health and
fitness gear; weather stations; and digital and conference
phones. The website also includes contact information
for our customer care department in case you need to
reach us, as well as frequently asked questions and
customer downloads.
Oregon Scientific will not be held liable for any bodily
injury, death, property damages, or any other claims of
whatever nature resulting from the misuse or negligence
of the product, whether intentional or unintentional.
Oregon Scientific will not be responsible for any
deviations in the usage of the device from those specified
in the user instructions or any approved alternations or
repairs of the product.
We hope you will find all the information you need on
our website, however if you'd like to contact the Oregon
Scientific Customer Care department directly, please
visit:
www2.oregonscientific.com/service/support
OR
Call 949-608-2848 in the US.
For international enquiries, please visit:
www2.oregonscientific.com/about/international/
default.asp
23
RMR939PA English R5
23
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
DECLARATION OF CONFORMITY
FCC STATEMENT
The information below is not to be used as contact for
support or sales. Please call our customer service number
the warranty card for this product) for all inquiries instead.
This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful
interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications.
We
Name:
Oregon Scientific, Inc.
Address:
19861 SW 95th Place, Tualatin,
Oregon 97062 USA
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
declare that the product
Product No.:
RMR939PA
Product Name: POLERMO Projection Clock with
Motion Alert
Manufacturer:
Address:
IDT Technology Limited
Block C, 9/F, Kaiser Estate,
•
•
Reorient or relocate the receiving antenna.
Phase 1, 41 Man Yue St.,
Hung Hom, Kowloon,
Increase the separation between the equipment and
receiver.
Hong Kong
•
•
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
is in conformity with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
Consult the dealer of an experienced radio/TV
technician for help.
1. This device may not cause harmful interference.
WARNING Changes or modifications not expressly
approved by Oregon Scientific for compliance could void
the warranty and your authority to use this equipment.
2. This device must accept any interference received,
including interference that may cause undesired
operation.
24
RMR939PA English R5
24
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
© 2004 Oregon Scientific. All rights reserved.
P/N: 000-000000-000
RMR939PA English Back R5
1
9/21/04, 2:40 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
|