Oregon Scientific Clock AS 316NE User Manual

LITETOUCH HIGLOTM BACKLIGHT  
Using the Lite Touch feature, the display will activate for three seconds so you  
can see the display in the dark. The light then automatically turns off.  
ENGLISH  
INSTRUCTION MANUAL  
FEATURES  
[ SEE FIG. 4 ]  
TRAVEL ALARM CLOCK  
WITH BACKLIGHT  
UNIQUE NIGHTFINDERTM FUNCTION  
Press the [NIGHT FINDER] button once and  
-
-
-
Unique Night FinderTM feature to locate the clock in the dark.  
appears on the display. The  
display backlight flashes every few seconds.  
AND NIGHT FINDER  
View the current time and alarm time simultaneously.  
Note: The NightfinderTM feature is intended for use in a very dark environment.  
You may not be able to see the flashing display under normal light conditions.  
Wake-up gently! The audible alarm initially sounds with a series of beeps  
at a low level, and gradually increases in volume.  
Model AS-316NE  
A)  
-
-
Five minute snooze function activates with unique Lite Touch feature.  
G. NIGHT FINDER button  
H. Buzzer  
Bright blue HiGloTM backlight illuminates the display for easy night-time  
viewing and flashes when the alarm goes off.  
I. Battery cover  
-
Protective hinged covers keeps buttons from resetting in transit and also  
acts as a table-top stand.  
[ SEE FIG. 6 & FIG.7 ]  
IMPORTANT:The NightfinderTM should only be used in an unfamiliar enviroment,  
such as hotel room, so as not to drain the battery. Under constant use conditions,  
the battery life will be reduced significantly.  
DESCRIPTION OF PARTS  
A. Night Finder indicator  
B. Alarm ON/OFF indicator  
C. Down button  
THE RESET FUNCTION  
D. ALARM ON/OFF switch  
E. TIME SET/LOCK/ALARM SET switch  
F. Up button  
If your clock doesn’t operate properly, take out the battery. Wait for 30 seconds and  
then insert it back into the battery compartment to reset your clock display. You  
will then need to set the clock and alarm times again.  
B)  
A) 12 hour display  
MAINTENANCE  
B) 24 hour display  
When handled properly, this unit is engineered to give you years of satisfactory  
service. Here are a few product care instructions:  
[ SEE FIG. 1 ]  
1. Do not immerse the unit in water. If the unit comes in contact with water, dry  
it immediately with a soft lint-free cloth.  
INSTALLING AND REPLACING BATTERY  
2. Do not clean the unit with abrasive or corrosive materials. Abrasive cleaning  
agents may scratch the plastic parts and corrode the electronic circuit.  
The unit uses one AAA Alkaline battery.  
FIG. 1  
If the display becomes dim, removes the exhausted battery and follow these steps  
to replace it:  
3. Do not subject the unit to excessive: force, shock, dust, temperature, or  
humidity. Such treatment may result in malfunction, a shorter electronic life  
span, damaged batteries, or distorted parts.  
C)  
D)  
1. Slide the battery door in the direction of the arrow.  
2. Insert the AAA battery as indicated by the polarity symbols (+ and -) marked  
inside the battery compartment.  
4. Do not tamper with the unit’s internal components. Doing so will terminate  
the unit’s warranty and may cause damage. The unit contains no user-  
serviceable parts.  
3. Replace the battery compartment door.  
5. Only use new batteries as specified in this instruction manual. Do not mix  
new and old batteries as the old batteries may leak.  
TABLE STANDING  
To use the cover as a stand, rotate the hinged cover over the back of the clock.  
6. Read this instruction manual thoroughly before operating the unit.  
[ SEE FIG. 5 ]  
FIG. 2  
SPECIFICATIONS  
Operation  
: 0°C to 50°C (32°F to 122°F) temperature  
E)  
F)  
HOW TO SET THE CLOCK TIME  
1. Lift the cover to reveal the setting buttons.  
Accuracy  
: +/- 0.5 seconds per day  
Power Source  
: One pc. UM-4 or AAA’ size Alkaline battery  
(Alkaline battery required)  
2. Slide the [TIME SET/LOCK/ALARM SET] switch to the TIME SET  
position. The time on the top of display flashes [SEE FIG.2]:  
Dimension  
Weight  
: 82 x 64 x 15 mm / 3.23" x 2.52" x 0.6"  
(H x W x D)  
C) 12 hour display  
D) 24 hour display  
: 45 g / 1.6 oz. (without battery)  
3. Press the [UP] or [DOWN] arrow button to increase/decrease the setting in  
one minute increments until the desired hour and minute are displayed. Press  
and hold the [UP] or [DOWN] button for faster setting.  
FIG. 3  
4. When the correct time is displayed, slide the [TIME SET/LOCK/ALARM  
SET] switch to the LOCK position. The time display stops flashing and the  
time is set.  
CAUTION  
-
-
The content of this manual is subject to change without further notice.  
Due to printing limitation, the displays shown in this manual may differ  
from the actual display.  
HOW TO SET THE ALARM TIME  
1. Slide the [TIME SET/LOCK/ALARM SET] switch to the ALARM SET  
-
The contents of this manual may not be reproduced without the permission  
of the manufacturer.  
position. The alarm time on the bottom of the display flashes  
[SEE FIG.3]:  
E) 12 hour display  
F) 24 hour display  
Company Name: Oregon Scientific, Inc.  
FIG. 4  
Address: 19861 SW 95th Place, Tualatin, Oregon 97062, USA  
2. Press the [UP] or [DOWN] arrow button to increase/decrease the setting in  
one minute increments until the desired hour and minute are displayed. Press  
and hold the [UP] or [DOWN] button for faster setting.  
3. Slide the [TIME SET/LOCK/ALARM SET] switch to the LOCK position.  
CUSTOMER ASSISTANCE  
Should you require assistance regarding this product and its operation, please contact  
our customer care department at 541-868-8205 or via email at  
The alarm time display stops flashing and the alarm time is set.  
IMPORTANT: After your alarm time has been set, you MUST slide the [ALARM  
ON/OFF] switch to the ON position to activate the alarm.  
ABOUT THE ALARM  
WARRANTY  
1. Slide the [ALARM ON/OFF] switch to the ON position.An alarm ON/OFF  
indicator is displayed on the LCD display. Now the alarm will sound at the  
programmed time.  
This product is warranted to be free of manufacturing defects for a period of 3  
months from date of retail purchase. Defective product should be directed to the  
place of retail purchase for exchange. Should this not be possible, contact our  
customer care department for assistance and a return material authorization. No  
returns may be made without a return authorization. Please retain your retail  
receipt as you may be asked to provide a copy of it for proof of date purchased.  
FIG. 5  
2. The alarm wakes you gently with a series of beeps that gradually increase in  
volume.  
3. To silence the alarm slide the [ALARM ON/OFF] switch to the OFF position.  
This warranty does not cover product subjected to abuse, misuse, accidental  
damage or tampering.  
The alarm indicator disappears from the display and the alarm is deactivated.  
Note :  
Remember, you must slide the [ALARM ON/OFF] switch to the ON position to  
use again. However, for your convenience, the alarm will automatically shut off  
after one minute and will sound again at the same time the next day.  
HOW TO USE THE SNOOZE  
The Lite Touch feature enables you to activate the five minute snooze by gently  
rocking the alarm clock backwards on its stand with the touch of your fingers.  
FIG. 6  
[ SEE FIG. 4 ]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIG. 7  

Miele Washer W 4446 WPS User Manual
Miller Electric Welder OM 227 398D User Manual
MTX Audio Portable Speaker MONITOR5i User Manual
NEC Projector VT460 User Manual
Night Owl Optics Digital Camera Executive Pen Camera User Manual
NordicTrack Treadmill 831298821 User Manual
N Tron Switch 304TX N User Manual
Oregon Weather Radio WR608 User Manual
Panasonic IP Phone KX T7050 User Manual
Panasonic Network Card 2SC3936G User Manual