Oregon Blood Pressure Monitor BPW128 User Manual

LOG BOOK  
:
Age:  
Weight:  
kg/lbs  
22.2  
10:12  
2
21.2  
10:05  
mmHg  
220  
200  
180  
160  
140  
120  
100  
80  
x
x
x
x
x
x
60  
85 90  
158 155  
/ min  
92 93  
110 112  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
WRIST TYPE BLOOD PRESSURE  
MONITOR  
INFORMATION CONCERNING THE CE  
SYMBOL  
ThisdevicecomplieswiththeEuropeanregulationsbasedonthe  
Medical Products Code, and bears the CE mark “CE0123”. The  
device has been quality inspected according to EG guideline  
93/42/EWG and tested in compliance to the EN1060-1  
Non-invasivesphygmomanometers-Part1,Generalrequirements  
and EN1060-3 Non-invasive sphygmomanometers-Part 3:  
Supplementary requirements for electromechanical blood  
pressure measuring systems. It is therefore not subject to  
calibration regulations and does not bear a calibration stamp.  
MODEL: BPW128  
USER’S MANUAL  
INTRODUCTION  
Thank you for purchasing the Wrist Blood-Pressure Monitor  
(BPW128). This unit has been constructed using reliable circuitry  
and durable materials. Used properly, this unit will provide years of  
satisfactory use.  
The CE mark further indicates that this blood pressure monitor  
meetsthegeneralrequirementsforelectronicproductsasregards  
resistance to electromagnetic interference. Malfunctioning may  
however occur in the proximity of extremely strong  
electromagnetic fields.  
Before use please note:  
-
-
This device is intended for non-invasive measuring and  
monitoring of arterial blood pressure. Designed for use on  
the wrist, it is not intended for use on other extremities or  
for other functions other than obtaining a blood-pressure  
measurement.  
In accordance with the “Ordinance for Operators of Medical  
Products”, a technical inspection must be carried out if this  
device is used for industrial or commercial purposes.  
If the cuff pressure exceeds 300mmHg, this unit will  
automatically deflate. Should the cuff not deflate when  
pressures exceeds 300mmHg, the user is required to detach  
the cuff from the wrist.  
-
-
Do not begin medical treatment based solely on obtained  
measurement values from this device. Consult a physician  
for treatment advice.  
To avoid measurement errors, read this manual carefully  
before use.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
DESCRIPTION AND FUNCTION OF  
PARTS  
F
A
A. Liquid Crystal Display (LCD) and protective cover  
- Large easy-reading display  
- 5 functional symbols  
- Systolic [SYS/mmHg], Diastolic [DIA/mmHg], Mean  
[MAP/mmHg], Pulse [pul/min.]and date & time display.  
E
C
B. Battery compartment  
Houses two (2) LR03 /AAA/ UM4 size 1.5V batteries  
D
C.  
D.  
Button  
- For time adjustment.  
B
Button  
- Activates and deactivates the unit and initiates pressure  
measuement process.  
E.  
/ Button  
- Recall memory or increases a value.  
F. Wrist cuff  
- For wrapping around the wrist.  
G. Storage container  
G
- Houses and neatly stores the unit.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
DISPLAY-SYMBOL DESCRIPTION  
INSTALLING BATTERIES  
1. Slide battery cover off.  
2. Install batteries first. Ensure  
correct polarity.  
Symbol  
Description  
Explanation  
Battery Type:  
2 Alkaline LR03 (AAA)size  
3. Replace the cover.  
Appears when  
measurement value is  
recalled from memory  
Memory Mark  
Replace the batteries if:  
1. the weak battery mark appears  
in the display  
Appears when batteries  
should be replaced  
Weak Battery  
Inflating Mark  
Air releasing  
2. nothing appears in the display  
when the power is switched on.  
Appears when inflating  
until pressure is enough  
If not disposed of properly, batteries can be harmful.  
Protecttheenvironmentbytakingexhaustedbatteries  
to authorized disposal stations.  
Appears when cuff air is  
exhausting  
Note:  
When battery power is low, replace all the batteries.  
Pulse Mark  
Shows the pulse rate per  
minute  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
PROPER EQUIPMENT SETUP  
1. Removeallwatches,jewelry, etc. priortoattachingthewristmonitor. Clothingsleevesshould berolledupandthecuffshouldbewrapped  
on bare skin for correct measurements.  
2. Apply cuff to left wrist with palm facing up.  
3. Make sure the edge of the cuff is about 1 cm from the plam.  
4. In order to ensure accurate measurements, fasten the velcro strap securely around your wrist so there is no extra space between the cuff  
and the wrist. If the cuff is not wrapped tight enough, the measurement values will be inaccurate.  
5. The measurement values will be correct even if you wrap the cuff askew.  
6. If your physician has diagnosed you with poor circulation on your left arm, carefully place the cuff around your right wrist.  
1cm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
BLOOD PRESURE DEFINITIONS  
WHAT IS MEAN ARTERIAL PRESSURE  
(MAP)  
Information obtained from the World Health Organization (WHO)  
The Mean Arterial Pressure is the average pressure forcing blood  
through the arteries. It is not the average of the systolic and diastolic  
blood pressure. It corresponds to a state of balance between the  
compressive and expansive forces acting on the arterial wall when  
there is no distension of the arterial wall, either outward or inward.  
Hypertension  
systolic over 160  
diastolic over 95  
(high pressure)  
95  
90  
Hypertonia  
systolic 140-159  
diastolic 90-94  
(Border value)  
MAP is an excellent way to evaluate the stress on the walls of the  
vessels. It is useful to quickly evaluate excessive load on the  
cardiovascular system. Show the history of the MAP to your doctor  
mayhelpprovidingmoreinformationforhisreferencetounderstand  
your situation.  
Hypotension  
Normal  
(low pressure)  
systolic under 90  
range  
systolic 139  
diastolic 89  
Important:  
!
90  
Systolic (mmHg)  
140  
160  
Consult your doctor on Mean Arterial Pressure.  
OSCILLOMETRIC MEASURING METHOD  
This device adopts the Oscillometric Measuring Method to provide  
readings of not only Diastolic and Systolic blood pressure, but also,  
unique,MeanArterialPressure.TheOscillometricMeasuringMethod  
was first described by Marey in the late 1800s, several decades  
before Korotkoffs description of the auscultatory method. The  
Oscillometric Measuring Method is a good means to determine the  
systolic / diastolic / mean blood pressure based on the measurement  
of pressure oscillation during the cuff pressure deflation phase.  
please note:  
-Hypotension value is for reference only.  
-Blood pressure is considered high when either the diastolic  
or systolic blood pressure value exceeds normal range.  
-Consult a medical professional when blood-pressure values  
are outside of the normal range.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
MEASUREMENT  
With the individual in a sitting position and with the cuff attached as  
previously mentioned, a blood pressure reading can be obtained.  
Note:  
-
For accurate pressure measurement, take blood-pressure  
readings in a seated position. Avoid leaning back while  
the measurement is being taken.  
-
-
Ensure that the lower arm is raised so that the upper edge  
of the cuff is on the same level as the heart.  
Ideally, place the palm of the hand facing upwards.  
+
+
-
-
In order to ensure a proper measurement, sit quietly and  
avoid talking and moving the fingers and hand. Rapid  
movements or other activities may alter blood pressure  
readings.  
At any time, to stop the pressurizing process, press the  
"
"Button; the cuff will stop inflating andair will exhaust  
from the unit.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
HOW TO TAKE MEASUREMENT  
Refer to Fig1  
2sec  
Fig1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Note:  
1. Remove all watches, jewelry, etc. prior to attaching the wrist  
monitor. Clothingsleevesshouldberolledupandthecuffshould  
be wrapped on bare skin for correct measurements.  
2sec  
2. Apply cuff to left wrist with palm facing up.  
3. Make sure the edge of the cuff is about 1 cm from the plam.  
4. In order to ensure accurate measurements, fasten the velcro strap  
securely around your wrist so there is no extra space between the  
cuff and the wrist. If the cuff is not wrapped tight enough, the  
measurement values will be inaccurate.  
5. Press the " " Button, to start the measurement process.  
6. To interrupt the measurement, simply press button. The cuff  
will deflate immediatey after the button is pressed.  
7. Donottalkormoveyourarmorhandmuscles. Thismonitorwill  
re-inflate automatically if the system detects that your body  
needs higher pressure to measure your blood pressure.  
8. Each reading will be saved to the memory automatically after  
each measurement.  
9. Up to 30 measurements can be stored to the memory.  
HOW TO RECALL VALUES FROM  
MEMORY  
Fig 2  
Refer to Fig2  
Note:  
a. The latest measurement will be shown first.  
b. Every new press of the  
calls for one prior value stored.  
c. The date & time of measurement will be shown in the memory of  
the same time.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
HOW TO SET THE TIME  
Refer to Fig3  
mode  
Fig 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Note:  
AUTOMATIC POWER OFF  
1. Pressandholdthe [ ]buttonfor2seconds,thedisplaywillflash  
12h or 24h.  
The device will automatically switch off after about 1 minute.  
However, to conserve battery power, press the  
finished to turn the unit off.  
button when  
2. Press the [ ] button to select either 12 hour or 24 hour display.  
3. Press the [ ] button to accept  
4. The hour digits will flash. Press the [ ] button to set the hour  
5. Press the [ ] button to accept  
ERROR MESSAGES  
6. The minutes digits will flash. Press the [ ] button to set the  
minutes  
Description  
Display  
Remedies  
7. Press the [ ] button to accept  
Deflation period too long  
Err 1  
Do not move during deflation.  
8. Similarly, set the display for year, day / month or month / day  
setting, month and date.  
Check whether the unit is worn  
well on wrist and measure  
again.  
Err 2, 8,  
12, 13,  
14, 15  
9. Press the [ ] button to exit time date setting.  
Incorrect measurement  
Cuff is not fastened  
Check if battery power is low.  
Change all batteries and  
measure again.  
Fasten the cuff and measure  
again.  
Err 3  
Err 4  
Vigorous motion is being  
detected during  
measurement  
Stay calm and easy then  
measure again.  
Stay calm and easy then  
measure again.  
Err 5,  
6, 7  
Measurement error  
Calibration error  
Retry again, return the unit to  
the manufacturer for repairing  
if same symptom persists.  
Err 9,  
10,11  
(Repairing/Replacement  
charge free only if under the  
valid warranty. Proof of  
purchase is needed).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
MAINTENANCE, CLEANING AND CARE  
SPECIFICATIONS  
When handled properly, this unit is engineered to give years of  
satisfactory service.  
Measuring method  
Application  
: Oscillometric / non-invasive  
: Adults  
Here are a few product care instructions:  
Measurement location  
: Wrist section of lower arm  
Circumference (approx. )  
5.3"-7.7"(13.5-19.5cm)  
-
When not in use, store the unit in the protective plastic container  
provided with your purchase.  
-
-
Donotimmersetheunitinwater.Iftheunitcomesincontactwith  
water, dry it immediately with a soft lint-free cloth.  
Pressure Measuring range : 30 - 280mmHg  
Pulse Measuring Range  
: 30 - 200 pulse/min  
The unit casing and the cuff may be carefully cleaned with a soft,  
slightly moistened cloth. Do not use abrasive or corrosive  
cleaning agents which might damage the device.  
Accuracy  
: (Pressure) +/- 3mmHg  
(Pulse) +/- 5%  
-
-
Remove the batteries if the device will not be used for long  
periods of time.  
Operating environment  
Operation  
: 50°F ... 104°F (10°C...40°C)  
(10% ... 83% rel. hum.)  
When replacing batteries, use new batteries as specified in this  
instruction manual. Do not mix new and old batteries.  
-
-
Do not place objects on the cuff, or the main unit.  
Storage / Transport:  
-4°F...158°F (-20°C... 70°C)  
(10% ... 83% rel.hum.)  
Donotsubjecttheunittoexcessiveforce,shock,dust,temperature,  
or humidity. Such treatment may result in malfunction, a shorter  
electronic life span, damaged batteries or distorted parts.  
Power supply  
Dimensions  
: 3.V DC, two (2) LR03/AAA /UM4  
size batteries  
-
-
Donottamperwiththeunit’sinternalcomponents. Doingsowill  
terminate the unit’s warranty and may cause damage. The unit  
contains no user-serviceable parts.  
: approx. 3.1"(H)x3.0"(W)x1.3"(D)  
(80mm(H)x77mm(W)x34mm(D)  
: 4 oz (without battery)  
Weight  
If, one day, the device should not be required for further use,  
protecttheenvironmentbybringingittoyourdealerordesignated  
collection point for proper disposal.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Shouldyourequireassistanceregardingthisproductanditsoperation,  
please contact our Customer Care Department at 1-800-853-8883 or  
via email at [email protected].  
SYMBOL DESCRIPTIONS  
Please observe user’s manual  
Protection class BF  
!
WARRANTY  
This product is warranted to be free of manufacturing defects for a  
period of 12 months from date of retail purchase. Defective product  
should be directed to the place of retail purchase for exchange.  
DC (Direct current)  
Shouldthisnotbepossible,contactourcustomercaredepartmentfor  
assistance and a return material authorization. No returns may be  
made without a return authorization. Warranty exchanges require  
proof of date of purchase (purchase receipt showing date, place and  
product purchased).  
0 1 2 3  
This device is complied to American National Standard:  
ANSI/AAMI SP10-1992.  
This warranty does not cover product subjected to abuse, misuse,  
accidental damage or tampering.  
Manufacturer  
:
IDT Technology Limited  
9/F Kaiser Estate Phase 1  
41 Man Yue Street  
Hunghom, Kowloon  
Hong Kong  
IMPORTANT ADVICE - RETAIN FOR  
FUTURE REFERENCE  
For meaningful comparisons, it is suggested to measure the blood  
pressureundersimilarconditions. Forexample, dailymeasurements  
should be taken at approximately the same time or as suggested by  
a medical professional. Physical activity may affect blood pressure;  
restabout5minutesbeforeobtainingabloodpressuremeasurement.  
Customer Assistance  
:
Oregon Scientific, Inc.  
19861 SW 95th Place  
Tualatin, OR 97062  
U.S.A.  
Bloodpressuremeasurementsarenotatreatment.Initiatingtreatment  
or making changes to a treatment regime should not be implemented  
without first consulting a physician.  
website address:  
Measurement error will be indicated on the display. Check the cuff  
and tubing for possible kinks or air leaks. Before attempting a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
measurementagain, ensurethatthecuffisproperlyattached, thearm  
is in the proper position and that movement has been minimized  
during the measurement process.  
If the device does not function:  
-
Check that the unit is on. After about 3 minutes of inactivity,  
the unit will automatically turn off.  
-
Ensure that batteries are properly inserted. Batteries may be  
exhausted and require replacement. A battery-low indicator  
[
] will display to indicate that batteries are low and need  
changing.  
Measurement errors may occur in persons with very low blood  
pressure or heart-rhythm irregularities. For individuals with special  
health conditions consult a physician.  
Note:  
This device is intended for adult use only. Do not use  
this unit on children without first consulting a physician.  
CAUTION  
-
-
-
The content of this manual is subject to change with-  
out further notice.  
Due to printing limitation, the displays shown in this  
manual may differ from the actual display.  
The contents of this manual may not be reproduced  
without the permission of the manufacturer.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  

Miele Clothes Dryer T 9802 User Manual
Nady Systems Microphone DM 90 User Manual
NETGEAR Network Card MA311 User Manual
Nextar Digital Photo Frame N7S 100 User Manual
Nikon Telescope 25 8x25 EER User Manual
Olympus Microcassette Recorder V406171SU000 User Manual
Omega Speaker Systems Thermometer HH801A User Manual
Optoma Technology Flat Panel Television SP50A User Manual
Oregon Scientific Digital Camera ATC3K User Manual
Panasonic Smoke Alarm 4313 User Manual