When using an electrical appliance, basic  
precautions should always be followed,  
including the following:  
Table of Contents  
Maintenance and Customer Service, Plug Fitting Instructions,  
Accessories, Important Safety Instructions . . . . . . . . . . . . . . . page  
READ ALL INSTRUCTIONS BEFORE  
USING THIS VACUUM CLEANER  
2
3
Warranty, Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . page  
Parts List, Assembly, Operating Instructions,  
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page  
WARNING  
4
5
To reduce the risk of fire,  
electric shock, or injury:  
To Replace Filter Dust Bag, How to Replace a Worn Belt,  
To Adjust or Replace Brush, Using an Oreck Fresh Air® Tab,  
Bulb Replacement, Stuffing or Blockage . . . . . . . . . . . . . . . . . page  
• Do not leave appliance unattended when plugged in.  
Unplug from outlet when not in use and before servicing.  
• Do not use outdoors or on wet surfaces.  
• Do not operate the unit while in the upright and locked  
position.  
• Do not let the unit run while in any one stationary position  
for any period of time. Keep the unit moving while in  
operation.  
Maintenance and Customer Service  
Your Oreck vacuum cleaner is a product of precise engineering. The  
motor bearings are permanently lubricated and should not be oiled. If  
you require additional information or have problems with your Oreck  
vacuum, you may call ORECK customer service at: 0845 603 0153  
Or write to:  
• Do not allow to be used as a toy. Close attention is  
necessary when used by or near children.  
Oreck UK  
P.O. Box 201  
Exeter  
Devon  
EX1 1XB  
• Use only as described in this manual. Use only  
manufacturer’s recommended attachments.  
• Do not use with damaged cord or plug. If appliance is not  
working as it should, has been dropped, damaged, left  
outdoors, or dropped into water, return it to a service  
center or call customer service at: 0845 603 0153.  
• Do not pull or carry by cord, use cord as a handle, close  
door on cord, or pull cord around sharp edges or corners.  
Keep cord away from heated surfaces.  
Please specify the model number and serial/code number which can be  
found on the data plate on the back of the vacuum.  
Save your sales or purchase slip. Should your Oreck appliance require  
warranty service, present this slip to the Authorized Service Center as  
your proof of purchase date.  
• Do not run appliance over cord.  
• Do not unplug by pulling on cord. To unplug, grasp the  
plug, not the cord.  
Plug Fitting Instructions  
• Do not handle plug or appliance with wet hands.  
• Do not put any object into openings. Do not use with any  
opening blocked; keep free of dust, lint, hair and anything  
that may reduce air flow.  
The wires in this main lead are coloured in accordance with the  
following code:  
Blue: Neutral  
Brown: Live  
• Keep hair, loose clothing, fingers and all parts of body  
away from openings and moving parts.  
• Do not use to pick up anything that is burning or smoking,  
such as cigarettes, matches, or hot ashes.  
• Do not use without filter bag assembly in place.  
• Turn off all controls before unplugging.  
As the colours of the wires in the main lead of this appliance may not  
correspond with the coloured markings identifying the terminals in your  
plug, proceed as follows;  
The wire which is coloured Blue must be  
connected to the terminal which is  
marked with the letter N or coloured  
Black.  
• Use extra care when cleaning on stairs.  
• Do not use to pick up flammable or combustible liquids,  
such as gasoline or lighter fluid, or use in areas where  
they may be present.  
The wire which is coloured Brown must  
be connected to the terminal which is  
marked with the letter L or coloured Red.  
• Do not use appliance in an enclosed space where  
flammable, explosive or toxic vapors are given off by oil  
base paint, paint thinner, some mothproofing substances,  
or in an area where flammable dust is present.  
• Do not pick up toxic material such as chlorine bleach,  
drain cleaner, gasoline, etc. with this appliance.  
• Use caution when vacuuming over area rug edges and  
fringe.  
Neither wire is to be connected to the  
earth pin of the 3 pin plug.  
When changing fuse, replace with the  
same size.  
Accessories (Sold Separately)  
ITEM  
PART #  
CCPK8DW  
CCPK8  
0300604  
AIRTABS  
00965-0019  
SAVE THESE INSTRUCTIONS  
1. Dust Bag, 8 Pack, Hypo-Allergenic  
Dust Bag, 8 Pack, Regular  
2. Belts, 3 Pack  
3. Oreck Fresh Air® Tabs  
4. Light Bulb  
Household Use Only  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
Troubleshooting Guide  
ORECK MANUFACTURING COMPANY: (Oreck 21180 Johnson Road;  
Long Beach, MS, USA 39560 gives you the following warranty for this  
product only if it was originally purchased for residential use, not resale  
from Oreck or an Oreck Authorized Retail Dealer.)  
WARNING: Unplug cord from electrical  
outlet before servicing.  
SAVE SERVICE CALLS...CHECK THESE FIRST:  
Oreck will repair or replace, free of charge, to the original purchaser, any  
part that is found to be defective in material or workmanship within five (5)  
years of the date of purchase; ten (10) years on housing. This warranty  
applies to normal domestic use. Any commercial use of this product will  
void this warranty. This limited warranty covers the revolving roller brush  
for one (1) year for residential use.  
• Is the disposable filter dust bag full?  
• Are pores of filter dust bag clogged with powder or fine dust?  
• Is anything clogging the revolving brush, lower tube, intake opening,  
fan housing or connector assembly opening?  
• Is the belt in place and turning the brush?  
• Are the brush ends in the proper location?  
This warranty does not cover the replacement of expendable or  
consumable parts such as carbon motor brushes, edge brushes, belts,  
bulbs, disposable bags and other parts subject to normal wear unless  
they are defective in material or workmanship.  
• Does the brush turn freely? Are hair, string or rug fibers wound around  
the brush?  
PROBLEM  
CLEANER  
POSSIBLE SOURCE  
AREAS TO CHECK  
This warranty does not apply to any part subjected to accident, abuse,  
alteration, misuse, damage caused by act of God, the use of voltages  
other than indicated on the serial number displayed on this product or  
service of this product by other than Oreck or a participating Factory  
Authorized Service Center.  
Not plugged in  
properly.  
Be sure cleaner is  
firmly plugged into  
wall outlet.  
WILL NOT RUN  
Oreck does not authorize any person or representative to assume or  
grant any other warranty obligation with the sale of this product.  
No electricity in wall  
outlet.  
Check electrical  
source–fuse or  
circuit breaker.  
Oreck’s warranty is valid only if you retain proof of purchase from Oreck  
or an Oreck Authorized Retail Dealer for this product. If you purchase this  
product from any other source, your purchase is “AS IS,” which means  
Oreck grants you no warranty, and that you, not Oreck, assume the entire  
risk of the quality and performance of this product, including the entire  
cost of any necessary servicing or repairs of any defects.  
CLEANER  
DOES NOT PICK UP  
Filter bag is full.  
Replace filter bag. See  
To Replace Paper  
Filter Dust Bag.”  
Nozzle or intake  
pivot clogged.  
Clear obstruction.  
Replace belt.  
This warranty is in addition to your statutory and other legal rights.  
Reconditioned units carry a 6 month warranty from date of purchase.  
Belt is broken or  
stretched.  
Brush is worn.  
See “To Adjust or  
Replace Brush.”  
Bag tube clogged.  
Clear obstruction.  
Change bag.  
Bag pores are  
clogged with fine  
dust.  
Impeller fan is  
broken.  
Return to Service  
Center for repair.  
Revolving brush is  
not even at both  
ends.  
Check brush roll end  
cards. Make sure  
words “OLD” or “NEW”  
match at each end.  
ALL OTHER SERVICING SHOULD BE DONE BY AN  
ORECK AUTHORIZED SERVICE CENTER.  
CALL CUSTOMER SERVICE HOT LINE  
0845 603 0153  
Whenever calling, please be sure to have your model and serial  
number from data plate.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. If at any time the machine does not pick up properly or makes an  
unusual noise, STOP OPERATION and service.  
Parts List  
4. Although your upright will pick up pins, paper clips, and other  
small objects, it is recommended that these be removed from the  
floor before you vacuum. Failure to do so may result in permanent  
damage to the motor suction fan and its housing.  
To assist you in identifying components of your vacuum, the parts have  
been numbered as follows:  
10  
1
2
3
4
5
6
7
8
9
Handle section, upper  
Tube, lower  
Power head  
Outer bag  
Paper filter dust bag  
Power cord  
Retaining spring  
Bag tension bar  
Zip fastener  
5. WARNING: Do not use your vacuum cleaner on damp or wet  
surfaces. This will cause damage to the vacuum cleaner and is  
dangerous to the user. Damage caused by use on wet or damp  
surfaces is not covered under warranty.  
11  
9
1
12  
6. REPLACE THE BELT EVERY 6 MONTHS.  
7. Change the disposable filter dust bag at least once a month—  
even if it is not full! The collected dust in the dust bag can cause  
odor, attract moisture, and can affect the efficiency of the cleaner.  
13  
5
4
8. DO NOT run the vacuum cleaner over the cord. The revolving  
brush could damage the cord.  
10 On/Off switch  
11 Cord hook  
2
9. Use caution when vacuuming over area rug edges and fringe.  
6
12 Plastic loop/cable clamp  
13 Connector assembly  
14 Fan housing  
General Information  
15 Cord assembly  
14  
7
8
15  
The performance of your new cleaner greatly depends upon care and  
maintenance. The instructions in this manual will guide you in  
performing basic care and maintenance. To obtain the most satisfying  
years of service read the instructions and keep them handy for future  
reference.  
3
Assembly  
Disposable Paper Filter Dust Bags  
fig. 1 Before assembling appliance, remove two screws from  
Disposable paper filter dust bags play a very important role in the  
efficiency of your ORECK vacuum cleaner. The purpose of the paper  
bag is to trap dirt, but at the same time it must be porous enough to  
allow air to pass through. If the paper bag becomes clogged, no air can  
pass through the cleaner and cleaning cannot take place, regardless of  
the cleaner’s power.  
connector assembly. Remove cardboard insert by pulling  
upward.  
fig. 2 With ON/OFF switch facing the front of the unit, slide  
upper handle section over matching section of the  
connector assembly. Insert short screw into top hole and  
long screw into bottom hole then tighten firmly until  
handle is no longer loose.  
To keep your cleaner operating at maximum efficiency, change the dust  
bag frequently. DO NOT FILL ABOVE THE LINE INDICATED ON THE  
DUST BAG.  
Be sure the disposable paper filter dust bag is installed properly.  
fig. 3 Attach cord to cord clip by pressing cord above and  
All paper dust bags are not the same. Your ORECK disposable  
dust bags have been designed to be used with the ORECK cleaner.  
Using bags other than genuine ORECK TYPE CC disposable bags  
will affect the cleaning ability of your cleaner and could cause  
damage to it.  
below clip ensuring the cord is fully rested in clip.  
Operating Instructions  
The Belt  
The belt on your vacuum cleaner controls the speed of the revolving  
brush and is very important for the effective operation of the cleaner. If  
the belt becomes stretched or cut, it will cause the revolving brush to  
stop completely or slow down. See instructions in the manual for  
replacing belt.  
Make sure disposable paper filter dust bag is in place. DO NOT operate  
the cleaner without a paper filter dust bag. Plug the power cord into an  
electrical outlet and press the On(l) - OFF(O) switch on handle assembly  
when ready to operate.  
An extra belt is stored in the baseplate of your cleaner. When  
buying replacement belts, use ONLY ORECK genuine belts. Belts  
other than Oreck belts will not operate the revolving brush  
correctly and may create undue stress which will cause damage to  
the motor and brush bearings. Using belts other than ORECK belts  
will void the warranty.  
Up-Position Lock  
fig. 4 Place foot on power head and lean handle back gently to release  
lock for vacuum use. Return handle to the full upright position to  
engage lock.  
NOTE: Do not operate the unit while in the upright and locked position.  
Do not let the unit run while in any one stationary position for any period  
of time. Keep the unit moving while in operation.  
Lubrication  
The vacuum cleaner motor bearings are factory lubricated and sealed.  
Further lubrication is not required.  
For Easy Power Cord Storage  
General Cleaner Care  
fig. 5 Wrap power cord around cord hook on handle and cord hook on  
At least once a month, check for and  
remove excessive lint, string or hair from  
revolving brush.  
connector.  
Operating Recommendations  
Wipe the outside of the cleaner with a  
damp cloth. Also clean the connector  
deflector assembly area, base of cleaner  
and fan housing area. If there is dust in  
the outer bag, vacuum it or shake it out.  
This new ORECK XL High-Speed Upright is one of the finest, fastest,  
and strongest units in its class. You’ll love the way it cleans, gets under  
things, and it’s SO lightweight and easy to use.  
The following are a few simple suggestions regarding its operation:  
1. When inserting a new disposable paper filter dust bag—FIRST  
PUFF OUT and OPEN THE BAG.  
A little preventative maintenance will  
keep your cleaner looking new and will  
ensure continued cleaning effectiveness.  
2. When the disposable filter dust bag is full, REPLACE IT.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: The bearing assembly setting marked "OLD" has no ribs on the  
top of the assembly. The one marked "NEW" has several ribs. When  
rotating bearings, make sure both bearing assembly settings are the  
same and face up when replacing the brush roll.  
CAUTION—Wood Floors, Soft (Vinyl, Asphalt Tile, etc.) Floor  
Surfaces and Polished Floor Finishes  
Use floor and floor finish manufacturer’s recommended methods of  
cleaning. The metal strip on the base of the cleaner could be damaged  
if used on concrete or abrasive surfaces, and, therefore, cause damage  
to wood floors, soft (vinyl, asphalt tile, etc.) floor surfaces and polished  
floor finishes. The roller brush may also scuff very soft finishes. Do not  
operate the unit while in the upright and locked position. Do not let the  
unit run while in any one stationary position for any period of time. Keep  
the unit moving while in operation.  
fig. 16 Reassemble the belt and the baseplate and check bristle height  
above baseplate at each end of brush.  
If a previous adjustment has already been made and bristle height does  
not extend above baseplate, a new brush assembly should be ordered.  
IMPORTANT: Unless the brush is worn as indicated above, both  
bearings must be in the “NEW” position. When rotating, both  
bearings must be in the “OLD” position. Unmatched settings will  
cause damage to your machine.  
XL3605HH: Celoc® Hypo-Allergenic Filter System  
The Celoc SMMS outer bag of your vacuum cleaner is high filtration  
medical material designed to filter the smallest of dust particles. It is  
important the inside of the outer bag be cleaned. Vacuum the inside of  
the outer bag or hand wash, turned inside out, with warm water, and air  
dry. For best results, the Celoc SMMS outer bag should be replaced  
once a year. The Celoc layered disposable inner dust bag must be  
replaced once a month even if it is not full. Change it more often if it is  
used in extremely dirty areas. Increase the cleaning power of your  
vacuum by changing the bag often.  
®
Using An Oreck Fresh Air Tab  
fig. 20 Your ORECK XL vacuum cleaner has a special ORECK FRESH  
AIR® tab pocket. This light-colored pocket is located inside the  
vinyl bag in the area where the paper disposable bag attaches  
to the intake tube. Insert tablet in pocket if desired.  
Bulb Replacement  
To Replace Filter Dust Bag  
WARNING: Unplug cord from electrical  
outlet before servicing.  
fig. 21 Remove lamp housing by removing two (2) screws in the the  
top of the lamp housing. Pull burned out bulb from holder and  
replace with new bulb. Use only Oreck replacement parts.  
Reassemble lamp housing by replacing two screws in the top of  
the lamp housing.  
WARNING: Unplug cord from electrical  
outlet before servicing.  
BAG REMOVAL:  
fig. 6 Unzip outer bag completely.  
fig. 7 Pull bag cardboard collar to release bag dock door from  
connector. Bag dock door will hinge downward.  
Stuffing or Blockage  
fig. 8 Gently pull bag cardboard collar upward out of the bag dock.  
The dust seal will close automatically.  
IMPORTANT: On plush and new carpets, stuffing may occur inside the  
the intake tube and the lower tube assembly. This is due to excessive fuzz  
and loose cuttings in the carpet. Stuffing could occur for the first few  
cleanings until all the loose material is removed. Due to the high efficiency  
of the cleaner, many older carpets will cause stuffing when the cleaner is  
first used on them. If your vacuum cleaner does not pick up properly, or  
makes unusual noise and the outer bag does not fluff up or balloon open,  
follow these steps:  
BAG INSTALLATION:  
fig. 9 Slide the cardboard collar completely onto bag dock door.  
fig. 10 Firmly push bag dock door with both thumbs on indication point  
until it snaps.  
How to Replace a Worn Belt  
WARNING: Unplug cord from electrical  
outlet before servicing.  
WARNING: Unplug cord from electrical  
outlet before servicing.  
fig. 22 Check for blockage at the mouth of the intake opening. If there  
is blockage, remove it with long-nose pliers, a screwdriver or  
coat hanger. If you can not reach the blockage, remove  
baseplate (fig. 23).  
fig. 11 Remove the replacement belt from the storage channel.  
fig. 12 Remove the door by removing the hold down screw located on  
side of power head.  
fig. 13 Slide the door forward by prying open with a screwdriver or  
fig. 24 If the blockage is not at the base, remove lower tube. Unhook  
coin.  
retainer spring, releasing bottom of bag.  
fig. 14 Remove the belt from the motor drive shaft and brush roll pulley.  
fig. 25 Twist lower collar counterclockwise to slide up. Pull tube out of  
fig. 15 Loop the new belt over the motor drive shaft. Place the  
opposite end of the belt on the brush roll pulley. Rotate the  
brush roll three (3) complete revolutions to ensure that no part  
of the belt is overhanging the end of the motor drive shaft.  
base.  
fig. 26 Check for blockage. If blockage is in the tube, remove with a  
coat hanger.  
fig. 27 If tube is not blocked, look into fan housing. Remove debris  
fig. 13 Replace the door by sliding it into the groove at the bottom of  
with long-nose pliers, a screwdriver or coat hanger.  
the housing.  
fig. 25 To reassemble, check O-ring on tube, and replace if damaged.  
Vacuum will not operate properly without the tube O-ring. Slide  
O-ring to approximately 2" from base of tube. Replace tube by  
first lining up slot at base of tube with inner tab inside fan  
housing. Then reinsert tube and push down until the tube is  
seated. Make sure O-ring is in place against fan housing  
opening. Replace and tighten collar until collar locking tabs are  
locked in place.  
fig. 12 Replace the hold down screw and tighten.  
To Adjust or Replace Brush  
WARNING: Unplug cord from electrical  
outlet before servicing.  
fig. 16 To determine if the brush is worn, place a firm straight edge  
across the nozzle opening. If brush bristles do not extend  
beyond baseplate, brush should be adjusted.  
fig. 28 Make sure collar is not cross threaded on housing. Reattach  
bag spring (fig. 24).  
fig. 17 Remove the baseplate by removing 5 screws.  
fig. 29 Many times blockage occurs due to a full dust bag causing dirt to  
back down the air flow system. When that happens, the  
fig. 18 Remove the belt and brush roll from the housing.  
blockage will be at the top of the system, starting in the area  
where the dust bag connects to the connector assembly.  
fig. 19 Rotate both bearing assemblies at ends of brush roll to show  
"OLD" and replace in the holding channels in the housing.  
NOTE: If the above actions do not correct the problem, contact an  
Oreck Authorized Service Center or call the customer service center  
at: 0845 603 0153.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
©2005 Oreck Holdings, LLC. All rights reserved. All word marks, logos, product configurations, and registered trademarks are owned and used under the authority of Oreck  
Holdings, LLC. Printed in America.  
75630-03 REV A  
08/05 ECN# R-7873  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Washer Dryer wt945 User Manual
Moulinex Microwave Oven AFW2 User Manual
NEC Flat Panel Television P402 User Manual
Nokia Crib Toy C3 00 User Manual
NordicTrack Home Gym NTSY98960 User Manual
Omron Healthcare Nebulizer NE C28 User Manual
Optimus Home Theater System STAV 3580 User Manual
Oregon Scientific Radar Detector BAR182HG User Manual
Panasonic Power Hammer ey6812 User Manual
ParaBody Home Gym 435104 User Manual