S I M P L Y
A M A Z I N G ®
USER’S GUIDE
U2 5 0 5 RH
HIGH SPEED UPRIGHT VACUUM
CLEANER WITH
®
CLEANING SYSTEM
•IMPORTANT•
SAVE THIS BOOKLET!
Includes:
• Safety Warnings
• Warranty
• Operating Instructions
• Trouble Diagnosis
• Accessories
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance and
Customer Service
ACCESSORIES
ITEM
PART N UMBER
Your ORECK vacuum cleaner is a product of precise
engineering. The motor bearings are permanently
lubricated and should not be oiled. If you require
additional information or have problems with your
ORECK appliance, or to order new bags or spare
parts, you may call ORECK customer service at:
1. Dust Bag, 8 Pack, Saniseal®
Hypo-Allergenic
CCPK8DW
CCPK8
Dust Bag, 8 Pack, Regular
2. Belts, 3 Pack
0300604
AIRTABS
0 8 4 5 6 0 3 0 1 5 3
3. Oreck Fresh Air® Tabs
Or write to:
Oreck UK
P.O. Box 107
Exeter
Devon
EX2 8ZQ
Attention: Oreck Customer Service
Please specify the model number and serial/ code
number which can be found on the data label on the
back of the vacuum.
Save your sales or purchase slip. Should your
ORECK appliance require warranty service, present
this slip to the Authorized Service Center as your
proof of purchase date.
Warranty
ORECK MANUFACTURING COMPANY: (Oreck 1400 Salem Road;
Cookeville, TN, USA 38506 gives you the following warranty for this
product only if it was originally purchased for residential use, not resale
from Oreck or an Oreck Authorized Retail Dealer.)
Oreck will repair or replace, free of charge, to the original purchaser, any
part that is found to be defective in material or workmanship within two (2)
years of date of purchase; ten (10) years on housing. This warranty
applies to normal domestic use. Any commercial use of this product will
void this warranty. This limited warranty covers the revolving roller brush
for one (1) year for residential use only.
This warranty does not cover the replacement of expendable or
consumable parts such as carbon motor brushes, edge brushes, belts,
bulbs, disposable bags and other parts subject to normal wear unless
they are defective in material or workmanship.
This warranty does not apply to any part subjected to accident, abuse,
alteration, misuse, damage caused by act of God, the use of voltages
other than indicated on the serial number displayed on this product or
service of this product by other than Oreck or a participating Factory
Authorized Service Center.
Oreck does not authorize any person or representative to assume or
grant any other warranty obligation with the sale of this product.
Oreck’s warranty is valid only if you retain proof of purchase from Oreck
or an Oreck Authorized Retail Dealer for this product. If you purchase this
product from any other source, your purchase is “AS IS,” which means
Oreck grants you no warranty, and that you, not Oreck, assume the entire
risk of the quality and performance of this product, including the entire
cost of any necessary servicing or repairs of any defects.
This warranty is in addition to your statutory and other legal rights.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
To Replace Paper
Filter Dust Bag
Assembly
To assist you in identifying
components of your vacuum,
the parts have been numbered
WARNING: Unplug cord from
electrical outlet before servicing.
10
11
BAG REMO VAL:
as follows
:
9
1 Handle tube, upper
2 Tube, lower
3 Power head
4 Outer bag
5 Paper filter dust bag
6 Power cord
7 Retaining spring
8 Bag tension bar
9 Zip fastener
1
1. Unsnap bag door from base.
12
2. Gently pull bag from
cardboard collar upwards.
16
5
13
4
2
6
10 On/ off switch
11 Cord hook
12 Plastic loop/ cable clamp
13 Connector assembly
14 Fan housing
7
14
8
15
15 Cord assembly
16 Cord Strain Relief Assembly
3
3. XL2605HH: Dust seal will
close automatically
1
2
TAB
BAG IN STALLATIO N :
1. Slide the cardboard collar
completely onto bag dock
door.
Before assembling appliance,
remove two screws from
connector assembly. Remove
cardboard insert by pulling
upward (fig 1 ).
3
ENFONCEZ JUSQU’À
ENTENDRE UN BRUIT
PRESIONE HASTA
ESCUCHAR UN
CHASQUIDO DE SUJECIÓN
With ON/ OFF switch facing the
front of the unit, slide upper
handle tube over matching
section of the connector
assembly. Hold tab of cord
strain relief flush with TO P hole in connector assembly. Insert
screw through hole in tab of cord strain relief and firmly tighten
to connector assembly. Insert remaining screw in bottom hole of
connector assembly and tighten firmly (fig 2 ).
NOTE: The power cord comes installed in the cord strain relief.
Should the power cord come loose, simply pinch the power cord
together and slide approximately 1 - 2 inches through hole in
cord strain relief. Carefully slide power cord over clamp on the
cord strain relief and pull excess until the power cord is tightly
rested under clamp.
2. Firmly push bag dock door
with both thumbs on
indication point until
it snaps.
Attach cord to cord clip by pressing cord above and below clip
ensuring the cord is fully rested in clip (fig 3 ).
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
To O p e ra te
All paper dust bags are not the same. Your ORECK
disposable dust bags have been designed to be used with the
ORECK cleaner. Using bags other than genuine ORECK
TYPE CC disposable bags will affect the cleaning ability of
your cleaner and could cause damage to it.
Make sure the disposable paper filter dust bag is in place.
DO NOT operate the cleaner without a paper filter dust bag.
Plug the power cord into an electrical outlet. Press the ON(l) -
OFF(O) switch on handle assembly when ready to operate.
Ge n e ra l In fo rm a tio n
An tib a cte ria l Te ch n o lo g y
The performance of your new cleaner greatly depends upon
care and maintenance. The instructions in this manual will
guide you in performing basic care and maintenance. To
obtain the most satisfying years of service read the instructions
and keep them handy for future reference.
Oreck added Antibacterial Technology to various touch
points, including the handle, outer bag and bag dock while
manufacturing this upright vacuum cleaner in order to
provide you with antimicrobial protection that continuously
fights the growth of microbes that can cause stains, odor and
product degradation. When microbes, such as bacteria,
mold and mildew come in contact with the product surface,
the antibacterial technology penetrates the cell wall and
disrupts key functions so they cannon grow or reproduce.
O p e ra tin g Re co m m e n d a tio n s
This new ORECK XL High-Speed Upright is one of the finest,
fastest, and strongest units in its class. You’ll love the way it
cleans, gets under things, and it’s SO lightweight and easy to
use.
Th e Be lt
The belt on your vacuum cleaner controls the speed of the
revolving brush and is very important for the effective
operation of the cleaner. If the belt becomes stretched or cut,
it will cause the revolving brush to stop completely or slow
down. See instructions in the manual for replacing belt.
The following are a few simple suggestions regarding its
operation:
1. When inserting a new disposable paper filter dust bag—
FIRST PUFF OUT and OPEN THE BAG.
2. When the disposable filter dust bag is full, REPLACE IT.
3. If at any time the machine does not pick up properly or
makes an unusual noise, STOP OPERATION and service.
4. Although your upright will pick up pins, paper clips, and
other small objects, it is recommended that these be
removed from the floor before you vacuum. Failure to do
so may result in permanent damage to the motor suction
fan and its housing.
5. WARN IN G: Do not use your vacuum cleaner on damp
or wet surfaces. This will cause damage to the vacuum
cleaner and is dangerous to the user. Damage caused by
use on wet or damp surfaces is not covered under
warranty.
An extra belt is stored in the baseplate of your cleaner. When
buying replacement belts, use ONLY ORECK genuine belts.
Belts other than ORECK belts will not operate the revolving
brush correctly and may create undue stress which will cause
damage to the motor and brush bearings. Using belts other
than ORECK belts will void the warranty.
Lu b rica tio n
The vacuum cleaner motor bearings are factory lubricated
and sealed. Further lubrication is not required.
Ge n e ra l Cle a n e r Ca re
At least once a month, check
for and remove excessive lint,
string or hair from revolving
brush.
6. REPLACE THE BELT EVERY 6 MONTHS.
7. Change the disposable filter dust bag at least once a
month—even if it is not full! The collected dust in the dust
bag can cause odor, attract moisture, act as a breeding
area and can affect the efficiency of the cleaner.
8. DO NOT run the vacuum cleaner over cord. The revolving
brush could damage the cord.
Wipe the outside of the
cleaner with a damp cloth.
Also clean the connector
deflector assembly area, base
of cleaner and fan housing
area. If there is dust in the
outer bag, vacuum it or shake
it out.
9. Use caution when vacuuming over area rug edges and
fringe.
Disp o sa b le Pa p e r Filte r Du st Ba g s
Disposable paper filter dust bags play a very important role
in the efficiency of your ORECK vacuum cleaner. The purpose
of the paper bag is to trap dirt, but at the same time it must
be porous enough to allow air to pass through. If the paper
bag becomes clogged, no air can pass through the cleaner
and cleaning cannot take place, regardless of the cleaner’s
power.
A little preventative maintenance will keep your cleaner
looking new and will ensure continued cleaning effectiveness.
CAUTIO N —Wo o d Flo o rs, So ft (Vin y l, Asp h a lt Tile ,
e tc.) Flo o r Su rfa ce s a n d Po lish e d Flo o r Fin ish e s
Use floor and floor finish manufacturer’s recommended
methods of cleaning. The metal strip on the base of the
cleaner could be damaged if used on concrete or abrasive
surfaces, and, therefore, cause damage to wood floors, soft
(vinyl, asphalt tile, etc.) floor surfaces and polished floor
finishes. The roller brush may also scuff very soft finishes. Do
not operate the unit while in the upright and locked position.
Do not let the unit run while in any one stationary position for
any period of time. Keep the unit moving while in operation.
To keep your cleaner operating at maximum efficiency,
change the dust bag frequently. DO NOT FILL ABOVE THE
LINE INDICATED ON THE DUST BAG.
Be sure the disposable paper filter dust bag is installed
properly.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
How to Replace a Worn Belt
To Adjust or Replace Brush
WARNING: Unplug cord from
WARNING: Unplug cord from
electrical outlet before servicing.
electrical outlet before servicing.
Remove the replacement
belt from the storage
channel.
To determine if the brush is
worn, place a firm straight
edge across the nozzle
opening. If brush bristles
do not extend beyond
baseplate, brush should be
adjusted.
Remove the baseplate by
removing 5 screws. Then,
remove the belt and brush
roll from the housing.
Remove the door by
removing the hold down
screw located on side of
power head.
Rotate both bearing
assemblies at ends of
brush roll to show “OLD”
and replace in the holding
channels in the housing.
Slide the door forward
by prying open with a
screwdriver or coin.
NOTE: The bearing
assembly setting marked
“OLD” has a smooth side.
The one marked “NEW”
has notches. When
Remove the belt from the
brush roll pulley and the
motor drive shaft.
Rotate and match bearing
rotating bearings, make
assemblies
sure both bearing
assembly settings are the
same and face up when
replacing the brush roll.
Loop the new belt over
the motor drive shaft.
Place the opposite end of
the belt on the brush roll
pulley.
Reassemble the belt and
the baseplate and check
bristle height above
baseplate at each end of
brush.
Rotate the brush roll three
(3) complete revolutions
to ensure that no part of
the belt is overhanging
the end of the motor
drive shaft.
If a previous adjustment
has already been made
and bristle height does not
extend above baseplate, a
new brush assembly
IMPO RTAN T: Un le ss
th e b ru sh is w o rn a s
in d ica te d a b o ve ,
b o th b e a rin g s m u st
b e in th e “ N EW ”
p o sitio n . W h e n
should be ordered.
Replace the door by
sliding it into the groove
at the bottom of the
housing. Replace the
hold down screw.
ro ta tin g , b o th
b e a rin g s m u st b e in
th e “ O LD” p o sitio n .
Un m a tch e d se ttin g s
w ill ca u se d a m a g e
to y o u r m a ch in e .
6
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Many times blockage occurs
due to a full dust bag
F
Stuffing or Blockage
causing dirt to back down
the air flow system. When
that happens, the blockage
will be at the top of the
system, starting in the area
where the dust bag connects
to the connector assembly.
See illustration F.
Connector
Deflector
Opening
Under certain conditions it is possible to stuff or block the intake
tube and the lower tube assembly. If your vacuum cleaner does
not pick up properly, or makes unusual noise and the outer bag
does not fluff up or balloon open, follow the following steps:
WARNING: Unplug cord from electrical
outlet before servicing.
1. Check for blockage at the
mouth of the intake
opening. See illustration A.
If there is blockage, remove
it with long-nose pliers, a
screwdriver or coat hanger.
If you can not reach the
blockage, remove
N O TE: If the “Stuffing or Blockage” actions do not correct the
problem, contact an ORECK authorized service center or call the
customer service center at: 0 8 4 5 6 0 3 0 1 5 3 .
A
B
Intake Opening
baseplate. See illustration B.
2. If the blockage is not at the
base, remove lower tube.
See illustration C. Unhook
retainer spring, releasing
bottom of bag. Twist lower
collar counterclockwise to
slide up. Pull tube out of
base. Check for blockage.
If blockage is in the tube,
remove with a coat hanger.
3. If tube is not blocked, look
into fan housing. See illus-
tration D. Remove debris
with long-nose pliers, a
IMPORTANT: On plush and new carpets, stuffing may occur
due to excessive fuzz and loose cuttings in the carpet.
Stuffing could occur for the first few cleanings until all the
loose material is removed. Due to the high efficiency of the
cleaner, many older carpets will cause stuffing when the
cleaner is first used on them.
Intake Opening
Retainer
Spring
®
Using An Oreck Fresh Air Tab
screwdriver or coat hanger.
4. To reassemble, check O-ring
on tube, and replace if
Your ORECK XL vacuum
cleaner has a special
Oreck Fresh Air® tab
pocket. This pocket is
located inside the outer
bag in the area where the
disposable paper bag
attaches to the intake
tube. Insert tablet in
pocket.
damaged. Vacuum will not
operate properly without the
tube O-ring. Slide O-ring to
approximately 2" from base
of tube. Replace tube by
first lining up slot at base of
tube with inner tab inside
fan housing. Then reinsert
tube and push down until
the tube is seated. Make
sure O-ring is in place
C
Fan
Housing
O-ring
against fan housing
opening. Replace and
D
tighten collar until collar
locking tabs are locked in
place. See illustration E.
Make sure collar is not cross
threaded on housing.
E
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Guide
WARNING: Unplug cord from
electrical outlet before servicing.
SAVE SERVICE CALLS...CHECK THESE FIRST:
•
•
•
Is the disposable filter dust bag full?
Are pores of filter dust bag clogged with powder or fine dust?
Is anything clogging the revolving brush, lower tube, intake
opening, fan housing or connector assembly opening?
Is the belt in place and turning the brush?
Are the brush ends in the proper location?
Does the brush turn freely? Are hair, string or rug fibers wound
around the brush?
•
•
•
PROBLEM
POSSIBLE SOURCE
AREAS TO CHECK
CLEAN ER
W ILL N O T RUN
Not plugged in
properly.
Be sure cleaner is
firmly plugged
into wall outlet.
No electricity in
wall outlet.
Check electrical
source–fuse or
circuit breaker.
CLEAN ER
DO ES N O T PICK UP
Filter bag is full.
Replace filter bag.
See “To Replace
Paper Filter Dust
Bag.”
Nozzle or intake
pivot clogged.
Clear obstruction.
Belt is broken or
stretched.
Replace belt.
Brush is worn.
See “To Adjust or
Replace Brush.”
Bag tube clogged. Clear obstruction.
Bag pores are
clogged with fine
dust.
Change bag.
Impeller fan is
broken.
Return to Service
Center for repair.
Revolving brush is Check brush roll
not even at both
ends.
end cards. Make
sure words “OLD”
or “NEW” match
at each end.
ALL O THER SERVICIN G SHO ULD BE DO N E BY AN
O RECK AUTHO RIZED SERVICE CEN TER.
CALL CUSTOMER SERVICE HOT LINE
0845 603 0153
Whenever calling, please be sure to have your model and
serial number from data plate.
©2009 Oreck Holdings, LLC. All rights reserved. All word marks, logos, product configurations, and registered trademarks are owned and used under the authority of Oreck
Holdings, LLC. Printed in America.
7 5 8 1 2 -0 1 REV A
8
0 1 / 0 9 ECN # R-9 2 8 2
Download from Www.Somanuals.com. All Manuals Search And Download.
|