S I M P L Y
A M A Z I N G
USER’S GUIDE
Compact
Canister
Vacuum
Models
BB877-RD
•IMPORTANT•
SAVE THIS BOOKLET!
Includes:
• Safety Warnings
• Parts List
• Operating Instructions
• Accessories List
• Warranty
• Trouble Diagnosis
Download from Www.Somanuals.com. All Manuals Search And Download.
To Operate
1
3
2
b
Plug cord into electrical outlet.
Shoulder Strap
fig. 1a Insert end of shoulder strap into slot in front of On/Off power
switch. Pull through three to four inches and insert into plastic
clip. One inch of strap must be completely through clip. Insert
other end of strap through slot located at back of handle. Insert
end into clip and pull through. Adjust length by pulling strap
through clip. Strap must go through both front and back clips.
a
SUCTION PORT
IMPORTANT: Before using shoulder strap, pull both ends to be sure it is
secure.
4
Power Switch
fig. 1b Push the power switch located on handle to the “ON” (I) position.
Hose & Tool Installation
fig. 2 The flexible hose uses a Shurlock™ locking system that
prevents hose removal unless intended. To install hose,
align “J” slot in hose coupling with tab inside the suction
port. Insert hose in port. Twist collar clockwise to lock
hose coupling in port. Twist counterclockwise and pull to
remove hose.
ADAPTER TUBE
BLOWER PORT
5
6
fig. 3 NOTE: When installing tools directly to blower or suction port
without using hose, tool adapter tube must be used.
Blower Port
fig. 4 The blower port is located at the rear of the machine. Installation
of tools is the same as described for suction port.
Attach Caddy and Insert Tools
fig. 5 Locate caddy clip indents at top rear corners of appliance. Place
appliance on firm, nonslip surface or hold in your lap. Grasp
handle firmly. Place end of caddy in outside indent then strongly
push and pull other end of caddy into opposite indent. Be sure
rims on caddy openings face up. Avoid trapping fingers when
caddy snaps on; painful pinch could result. If caddy needs to be
removed, a large flat-head screwdriver inserted under caddy clip
at indent can be used to carefully pry caddy loose.
7
8
fig. 6 Pull cord through center opening in caddy and push until it is
seated at back of slot at rear of center opening in caddy.
fig. 7 Insert crevice tool, brush and fabric tool into caddy in spaces
provided.
Cord Dump
fig. 8 Twist cord dump to easily release stored cord.
9
10
12
Maintenance
Changing the Filter Bag
fig. 9 Use only genuine Oreck XL filter bags. Stand unit on its back.
Twist knob counterclockwise to release front plate. Lift out front
plate.
fig. 10 Remove used bag and insert fresh bag. The cardboard rim fits
smoothly into the recessed top.
fig. 9 Replace the front plate and close unit by turning knob clockwise.
11
fig. 11 IMPORTANT: The white gasket glued in the housing must be in
place or unit will not operate properly. Replace if needed.
WHITE GASKET
Replacing Micro Filter
MICRO
FILTER
Stand unit on its back.
fig. 9 Stand unit on its back. Twist knob and lift out front plate.
fig. 10 Remove disposable bag.
fig. 12 Remove old filter from bottom inside unit. Replace with new
filter.
A replacement filter is supplied in each package of 12 Oreck XL filter
bags or you may order filters separately.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Do not pick up moist material or liquids.
Warranty
If fine materials such as soot, cement, plaster dust, copy machine
powder, etc. are picked up, the bag surface may seal and suction will
be reduced. Change bag when this occurs.
Alexander Nevsky Enterprises Inc. warrants the normal use of electrical
products during the warranty period if such products were used in
accordance with the user’s guide instructions.
•
Clean the disposable bag cavity and the outside of the canister with a
damp (not wet) cloth.
The product must be purchased from Alexander Nevsky Enterprises Inc.
or a retail dealer authorized by Alexander Nevsky Enterprises Inc. If you
purchase this product from any other source, Alexander Nevsky
Enterprises Inc. grants you no warranty and you, not Alexander Nevsky
Enterprises Inc., assume the entire responsibility for the quality of this
product including the entire cost of any necessary servicing or repairs of
any defects.
Accessories
ITEM
PART #
1. Replacement Germastat® Treated Filter Bags
12 Pk. with 1 Micro Filter
2. Replacement Micro Filter
3. Replacement White Bag Gasket
4. Fresh Air Tabs
PKBB12DW
72005-01
72017-02
AIRTABS
The warranty period is three (3) years; ten years (10) for the housing. The
duration of your warranty period begins with the day of your purchase with
the condition that you have a correctly completed warranty certificate and
only under the conditions of normal domestic use. If the product is used
for commercial purposes as in restaurants, café’s, hotels, etc. this limited
warranty is automatically voided.
Troubleshooting Guide
At your demand, any service center authorized by Alexander Nevsky
Enterprises Inc. will replace and/or repair all manufacturer’s defects free
of charge during the warranty period. Information about our service
centers in your region can be obtained from your sales person.
WARNING: Unplug cord from electrical outlet
before servicing
PROBLEM
POSSIBLE SOURCE
AREAS TO CHECK
ATTENTION!
Be sure to check the accuracy of the warranty certificate, the signature of
the sales person, the correct date of purchase and stamp on the warranty
certificate!
Not plugged in
properly.
Be sure cleaner is
firmly plugged into
wall outlet.
CLEANER
WILL NOT RUN
This warranty doesn’t apply in cases of:
No electricity in wall
outlet.
Check electrical
source–fuse or
circuit breaker.
• abuse
• misuse
Needs Service.
Take to service
center or call for
nearest service
center.
• incorrect warranty certificate or if changes have been made to the
warranty certificate
• intentional damage to product or the traces of inappropriate chemical
agents
CLEANER
Filter bag is full.
Replace filter bag.
See “To Replace
Paper Filter Bag.”
• damages made by animals or insects
DOES NOT PICK UP
OR HAS LOW
SUCTION
• the use of incorrect voltage other than indicated on the serial
number plate
Hose / Wand tool is
clogged.
Clear obstruction.
• using the product in a different manner than it was produced for
Air leak due to
missing or damaged
gasket.
Replace Gasket
• repairs, other intrusive procedures or the disassembling of the unit
performed by non-authorized repair facilities
• using other than manufacturer replacement parts
• damages caused by fire, flood or other reasons which are out of the
control of the manufacturer or the sales person of this product
ALL OTHER SERVICING SHOULD BE DONE BY AN
AUTHORIZED SERVICE CENTER.
Drive belts, revolving brushes, bulbs, disposable bags and other parts
subject to normal wear are not covered by this warranty. The amount of
warranty repairs cannot exceed the original purchase price..
Safeguards
WARNING: Unplug cord from electrical
outlet before servicing.
•
•
IMPORTANT: Make sure filter bag is in place. Do not operate
cleaner without filter bag. Damage to motor may occur.
Be sure bag gasket is in place. If the white bag gasket is damaged or
lost, replace at once.
(Part No. 72017-02)
•
For best results, change disposable filter bag regularly even if it is not
completely full. An extremely dirty bag or a bag close to full will affect
the suction of the cleaner and can create excessive motor heat that
could damage the motor. A good practice is to change filter bag every
30 days even if it is not full.
72197-01 REV A
©2003 Oreck Holdings, LLC. All rights reserved. All word marks, logos, product configurations, and registered trademarks are owned and used
10/03 ECN# R-7284
under the authority of Oreck Holdings, LLC.
Download from Www.Somanuals.com. All Manuals Search And Download.
|