®
S I M P L Y
A M A Z I N G
USER’S GUIDE
PROFESSIONAL
AIR PURIFIER
WITH
AIR8 Series
•IMPORTANT•
SAVE THIS BOOKLET!
Includes:
• Warranty
• Safety Warnings
• Parts List
• Operating Instructions
• Accessories List
• Trouble Diagnosis
Note: Graphics and logos on your Air Purifier
may vary from those shown in this manual.
Download from Www.Somanuals.com. All Manuals Search And Download.
Polarized Plug Notice
Maintenance and Customer Service
This product is equipped with a polarized alternating current line
plug (a plug having one blade wider than the other). This plug
will fit into the power outlet only one way. This is a safety
feature. If you are unable to insert the plug fully into the outlet,
try reversing the plug. If the plug should still fail to fit, contact an
electrician to replace the obsolete outlet. Do not defeat the
purpose of the polarized plug.
Your Oreck Air Purifier is a product of precise engineering. If you
require additional information or have problems with your Oreck
appliance, you may call ORECK customer service at:
USA: 1-800-989-3535 Canada: 1-888-676-7325
Please specify the model number and serial/code number which
can be found on the data plate on the back of the Air Purifier.
Save your sales or purchase slip. Should your Oreck appliance
require warranty service in the U.S.A., present this slip to the
Authorized Service Center as your proof of purchase date or, in
Canada, call customer service.
Warranty
ORECK MANUFACTURING COMPANY: (Oreck Manufacturing
Company gives you the following limited warranty for this
product only if it was originally purchased for residential use, not
resale from Oreck or an Oreck Authorized Retail Dealer.)
INTRODUCTION
Oreck will repair or replace, free of charge, to the original
purchaser, any part that is found to be defective in material or
workmanship within three (3) years of the date of purchase and
twelve (12) years for the Ionizer/Collector Cell for all residential
models. NOTE: If the unit is used commercially, a one (1) year
overall warranty applies.
The air you breathe is filled with thousands of particles of air
pollution. Some of the pollutants like dust and lint are large
enough to be visible to the naked eye, but pollutants such as
pollen, smoke, germs, bacteria, etc., are microscopic in size.
Your Oreck Air Purifier has been designed to capture and
destroy visible and invisible pollutants and provide you the
luxury of clean air living in your home or office.
This limited warranty does not cover the replacement of
expendable or consumable parts such as filters, cartridges, and
other parts subject to normal wear unless they are defective in
material or workmanship.
Airborne particles and odors are removed from air passing
through the unit by the process of electrostatic precipitation and
an activated charcoal odor absorber. The fragrance feature
releases a pleasant aroma with the newly cleaned air.
This limited warranty does not apply to any part subjected to
accident, abuse, commercial use, alteration, misuse, damage
caused by act of God, the use of voltages other than on the data
plate on this product or service of this product by other than
Oreck or a participating Factory Authorized Service Center.
How Your Oreck Air Purifier Works (fig.1)
Oreck does not authorize any person or representative to
assume or grant any other warranty obligation with the sale of
this product.
1. Polluted air enters the Air Purifier through the front grill. As
the air is pulled through, a Pre-Filter helps trap large particles
(hair, lint, etc.).
2. Positive Charging Wires electrostatically charge smaller
particles (dust, smoke, pollen, etc.).
Oreck’s limited warranty is valid only if you retain proof of
purchase from Oreck or an Oreck Authorized Retail Dealer for
this product. If you purchase this product from any other source,
your purchase is “AS IS,” which means Oreck grants you no
warranty, and that you, not Oreck, assume the entire risk of the
quality and performance of this product, including the entire cost
of any necessary servicing or repairs of any defects.
3. The positively charged particles then enter the negatively
charged Electronic Collector Cell, where the aluminum plates
attract and retain the particles and subsequently destroy
bacteria, mold, viruses, and fungi. It works like a powerful
magnet and the particles remain until the Electronic Collector
Cell is cleaned.
Oreck’s liability for damages to you for any costs whatsoever
arising out of this statement of limited warranty shall be limited
to the amount paid for this product at the time of original
purchase, and Oreck shall not be liable for any direct, indirect,
consequential or incidental damages arising out of the use or
inability to use this product.
4. The air then passes through a Charcoal Odor Absorber that
helps remove household odors.
5. Next, the Air Revitalizer (Ionizer) releases negative ions to
freshen the air. It provides a pleasant, clean smell. The Air
Revitalizer is designed to be left on continually to provide a
clean scent.
Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion
may not apply to you.
The negative ions created by the Air Revitalizer may also
combine with dust, causing the dust to fall out of the air. This
feature gives you an easy, centralized place to wipe away
dust. You can also turn off the Air Revitalizer (Ionizer) to limit
any dust collecting around the Air Purifier.
ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS
PRODUCT, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED IN DURATION TO THE WARRANTY
PERIOD, AND NO WARRANTIES, WHETHER EXPRESS OR
IMPLIED, WILL APPLY AFTER THIS PERIOD.
Finally, electronically cleaned air passes back into the room
through the top grill.
Some states do not allow limitations on the duration of implied
warranties, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
1
3
4
1
ELECTRONIC
CHARCOAL ODOR
PRE-FILTER
COLLECTOR CELL ABSORBER (OPTIONAL) POWERFUL FAN
POSITIVE
CHARGING WIRES
AIR
REVITALIZER
5
2
This is normal and only a test of the system.
Oreck Air Purifier Placement and Start-Up
5.AIR DIRECTION CONTROL: Slide switch on top of unit
controls the louvers and enables you to direct airflow to
desired areas.
1. Open box and check parts. Box should include one
Professional Air Purifier, Oreck fragrance cartridge, Charcoal
Odor Absorber and User’s Guide.
NOTE: You may notice an occasional sharp snapping
sound coming from your unit. This is a normal occurrence
called “arcing” and results as large particles of dust are
collected in the Electronic Collector Cell. Should prolonged
or continuous arcing occur, the Electronic Collector Cell
should be thoroughly cleaned and dried completely
2. Your Air Purifier draws in dirty air for cleaning. Place the Air
Purifier in a location where the dirty air is not drawn across
your head or body while sitting or sleeping.
3. Insert the Oreck fragrance cartridge (optional) and the
Charcoal Odor Absorber (optional).
The fragrance cartridge is located in the “User’s Guide”. Slide
the FRAGRANCE tab on the front control panel of the Air
Purifier to eject and the drawer will open (fig.2). Insert
fragrance cartridge and close the drawer.
2
5
The Charcoal Odor Absorber is located with the unit in
a separate plastic bag. The Charcoal Odor Absorber
snaps into the back of the Collector Cell (see instructions
with Absorber).
OPERATION
1
Your Air Purifier works best if you leave it in operation
continuously, and it provides multiple settings for convenient use
at any time.
4
2
1. MAIN POWER SWITCH: Turn the unit on by sliding the
power
switch to the fan speed you prefer: HI for maximum
cleaning -
MED for normal use - SILENCE for
SILENCE TECHNOLOGY®
quietest operation (fig.
2).
3
2.FRAGRANCE CARTRIDGE: Fragrance compartment switch
ejects drawer for access to fragrance cartridge. Insert
fragrance cartridge and close drawer. (One fragrance
cartridge is included.)
(See “Cleaning Collector Cell”).
Oreck Air Purifier’s Silence Technology
®
3.IONIZER POWER SWITCH: Turns the Ionizer ON or OFF.
The indicator light will glow green when ON and functioning
properly. The Ionizer provides a pleasant, clean smell. It can
be turned ON or OFF without impacting the Air Purifier’s
cleaning effectiveness.
The Oreck Professional Air Purifier offers Silence Technology®
for the quietest operation. The Collector Cell cleans as
effectively on the Silence setting as it does on the High setting -
only the fan’s speed changes. As a result, your Oreck Air Purifier
cleans as well on Silence as on High, but will clean the room
more slowly as it circulates less air.
4.POWER INDICATOR LIGHT: The indicator light will glow
green when the unit is operating normally. It will flash red
when the Collector Cell requires cleaning. NOTE: The light
will glow red for a moment when unit is first turned on.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
If wall mounted, remove unit from wall.
Additional Information
2.Loosen the front grill retainer screw at the front of the cabinet
bottom. Press in the lock (half-moon) on the left side and
remove the grill (fig. 3).
WARNING: DO NOT USE THIS ELECTRONIC AIR PURIFIER
WHEN OXYGEN TANKS ARE BEING USED OR IN THE
PRESENCE OF COMBUSTIBLE GASES.
3. Pull the Collector Cell out of the cabinet by using the two
IMPORTANT NOTES:
3
G
No air cleaner can protect against the harmful effects of
secondhand smoke.
G
Place or mount the Air Purifier near a standard electrical
outlet. Do not block either the air intake or outlet grill.
G
Never place your Air Purifier on soft surfaces (such as bed,
sofas or carpet), near computers or next to sources of heat
(such as stove tops, ovens, etc.)
G
Make sure the front grill is securely locked in place.
G
A safety switch is installed behind the grill of your electronic
Air Purifier. If the grill is not properly secured in place, the unit
will not operate. If your unit fails to operate, remove the front
grill and reinstall it, being sure that the lower right-hand side
of the grill (next to the control panel) is firmly locked in place.
4
G
Plug the power cord into the nearest available standard
electrical outlet. (See data label on bottom of your Air Purifier
for electrical specifications and power consumption.)
G
Do not use an extension cord to supply power to your Air
Purifier.
G
Do not place open flames (including candles) directly in front
MAINTENANCE
4. Snap off the Charcoal Odor Absorber from the back of the
Collector Cell. Change as necessary for continued odor
removal (fig. 5).
of the air purifier.
Cleaning the Cabinet
You can clean the Air Purifier cabinet with mild, non-abrasive
cleanser and a soft cloth. IMPORTANT: Unplug the unit from its
electrical power source. Do not spray cleansers or furniture
polish into louvers or grill areas.
5.Slide off Pre-Filter. This can be cleaned with the Collector Cell
and reused (fig. 6).
NOTE: Handle the Electronic Collector Cell with care.
Damaged metal plates and/or broken wires will cause the
Air Purifier to malfunction. (Do not wash the disposable
Charcoal Odor Absorber.)
6.Oreck’s Assail-A-Cell® cleaner is an excellent way to clean an
Electronic Collector Cell. Be sure to spray between each cell
plate and cover every surface. Allow product to soak for a few
minutes, not allowing it to dry. Rinse thoroughly with water.
For extremely heavy deposits, repeat the process.
If you prefer not to use Oreck’s Assail-A-Cell® cleaner, you
may also decide to soak the Electronic Collector Cell in warm
water in a kitchen sink or bathtub. Mild dish detergent (powder
or liquid) may be added to the water to help break down the
dirt on the Collector Cell. The Collector Cell should be allowed
to soak for two to three hours.
Cleaning the Electronic Collector
Cell
IMPORTANT: Do not try to clean the Collector
Cell by inserting a cloth, brush, or other
device between the cell plates. The Collector
®
Cell should be cleaned with Oreck’s Assail-A-Cell cleaner
or using soap and water (see
Step 6, in this section). Inserting objects in the
Collector Cell may damage it.
Indicator light is green under normal operation and
flashes red when the Collector Cell requires cleaning.
The red "WASH CELL" light will flash or illuminate
when it is time to clean your Collector Cell. Your Air Purifier is
still filtering the air when the red light illuminates.
Tobacco smoke (tar) is especially hard to remove from the
Collector Cell. If the Purifier has been cleaning tobacco
smoke, the Collector Cell may need to soak longer, or it may
need to be cleaned a second time.
It is not necessary to wait for the red "WASH CELL" light before
cleaning the Collector Cell. Even if the “WASH CELL” light is not
red, Oreck recommends cleaning the Collector Cell every 4 to 8
weeks, or more often if snapping becomes frequent.
In either case, the Collector Cell should be allowed to air dry
before re-inserting it. Oreck does not recommend the use of
heated or compressed air as part of the drying process.
Cleaning your Oreck Air Purifier is a snap too... and a must for
efficient operation. To clean proceed as follows:
1.Turn the unit off and unplug it from the electric power source.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing Fragrance Cartridge
5
1. Open Fragrance Cartridge compartment by sliding the
Fragrance compartment release switch (fig. 7).
2.Remove Fragrance Cartridge from center of the compartment
and replace with a new one (fig. 8).
3. Close compartment until it locks (fig. 9).
NOTE: One Fragrance Cartridge is included.
7
8
9
6
IMPORTANT: Dry the Collector Cell thoroughly outside of
the Air Purifier before reinstalling it into the Air Purifier.
Ensure that all areas including corners and areas that may
trap water are dry before reinstalling into the Air Purifier.
If the power indicator light is red after replacing Collector
Cell, then the Collector Cell is still wet. Remove Collector
Cell and allow it to finish drying
Replacing The Charcoal Odor Absorber
(Optional)
In addition to air purification, your Oreck Air Purifier provides the
additional benefit of odor removal. The odor removal function is
optional. Your Oreck Air Purifier will continue to remove harmful
airborne particles with its permanent Electronic Collector Cell
even if you choose not to use the optional Charcoal Odor
Absorber.
Odor absorption effectiveness will gradually deteriorate over
time unless the Charcoal Odor Absorber is replaced. While
every environment is different, Oreck suggests that the Charcoal
Odor Absorber be replaced every two months or as needed.
IMPORTANT: DO NOT wash the Charcoal Odor Absorber.
Replace, if necessary.
Replacing Collector Cell After Cleaning
1. Snap in the Charcoal Odor Absorber (fig. 5).
2. Slide in the Pre-Filter (fig. 6).
3. Slide Collector Cell into cabinet, using handles (fig. 4).
4. Replace front grill. Unit is now ready for operation (fig. 3).
NOTE: An occasional “arcing” sound is normal when
operating the unit immediately after cleaning the Cell and
should stop after a few minutes of operation.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Guide
ACCESSORIES &
Service problems that appear to be major can often be solved
easily. You can be your own troubleshooter by reviewing the
chart below. It pinpoints problems and how to correct them.
Remember, check the simple things first.
TROUBLESHOOTING
CALL CUSTOMER SERVICE HOT LINE
USA:1-800-989-3535 Canada: 1-888-676-7325
PROBLEM
CHECK
WHAT TO DO
1. Power Cord
2. Selector Switch
1. Plug in power cord
UNIT DOES NOT TURN
ON
Whenever calling, please be sure to have your model from the
data plate.
2. Set selector switch
for desired blower
speed.
3. Reinsert front grill
until it is flush with
cabinet front. Tap
grill lightly, if
necessary, to fully
insert.
Wash Collector Cell.
Make sure it is
thoroughly clean & dry
before re-installing it.
Accessories (Sold Separately)
3. Front Grill
ITEM
1.
2.
3.
4.
PART #
Pre-Filter
7780-8041
09-5510-7065
AT4PK7
Ionizer/Electronic Collector Cell
Charcoal Odor Absorber (Set of 4)
Wall Mounting Kit
Ionizer/Electronic
Collector Cell
INDICATOR LIGHT ON
UNIT IS FLASHING RED
OR HAS TURNED RED
8660-0201
5.
Oreck Fresh Air® Scent Cartridges
Spring Mulberries®, 8pk.
Blooming Jasmine®, 8pk.
FA2PK
FA3PK
Ionizer/Electronic
Collector Cell
1. Collector Cell may
not be completely
dry.
2. Cell may be
damaged with a
broken wire.
3. The “Dirty Cell”
sensor may not be
working correctly.
4. If you believe the
Collector Cell is
damaged or the unit
is not working
RED INDICATOR LIGHT
WILL NOT TURN OFF
USA: 1-800-989-3535
Canada: 1-888-676-7325
Outside the USA and Canada,
contact your local Oreck Distributor.
correctly, return the
unit to the Service
Center.
Ionizer/Electronic
Collector Cell
UNIT DOES NOT
Wash Collector Cell.
REMOVE POLLUTANTS
Make sure it is
thoroughly clean & dry
before re-installing it.
UNIT SPARKS,
Ionizer/Electronic
Collector Cell
1. Sparking or
popping noise
CRACKLES AND POPS
occurs when a
large particle is
captured in the
Collector Cell.
2. If the unit is arcing
excessively, the
Cell may be dirty.
Try cleaning the
Collector Cell.
3. If excessive
arcing continues
after proper cleaning,
the Collector Cell
may be damaged
or wet. Return unit
to the Service
Center.
Replace Charcoal
Odor Absorber.
Old Charcoal Odor
Absorber
DOES NOT REMOVE
ODOR
Check all the above
points
UNIT STILL DOES NOT
OPERATE PROPERLY
Return unit to the
Service Center.
ALL OTHER SERVICING SHOULD BE DONE BY AN
ORECK AUTHORIZED SERVICE CENTER.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
© 2006 Oreck Holdings, LLC. All Rights Reserved. All word mark, logos, product configurations, and registered trademarks are owned and used under the authority
of Oreck Holdings, LLC.
3323-8889 REV K
01/06 ECN# R-8239, R-8240
Download from Www.Somanuals.com. All Manuals Search And Download.
|