Getting Started  
General Information  
The LGZ 7225 CCD Scanner utilizes state-of-the art imaging technology similar to that found in digital  
cameras, fax machines and video camcorders. The captures an “image” of the bar code and converts it into  
digital signals that the host computer understands.  
The scanner automatically recognizes most common bar code symbologies.  
The scanner, which utilizes miniature, surface-mounted electronics, has no moving parts and will provide  
years of trouble-free operation.  
The LGZ 7225 is available in several different interface configurations.  
ƒ Keyboard Wedge (PS2 or AT/XT)  
ƒ RS 232  
ƒ USB  
Unpacking  
Remove the scanner from its packaging and inspect it for damage. Save the carton and packing material. If  
the scanner was damaged in transit, call the dealer or distributor from whom you purchased it. If you  
purchased it directly from Opticon, call Opticon Customer Service Dept. at 800-636-0090.  
Opticon Customer Service and Support  
If you have any questions or need assistance with installing or programming your scanner call Opticon  
Customer Service Department at (800) 636-0090.  
Before you call, record the model number of the scanner. This information is located on the bottom side of  
the scanner. Also please have the scanner available plus some bar codes to scan.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
LGZ7225 Long Range Handheld CCD Spec  
160 g (cable not included)  
Cable - K/B Wedge  
Cable - universal type  
Connector type  
Straight 2.0 m  
Straight 2.3 m  
RJ-45 phone jack connector  
ABS plastic  
Case material  
Cushion material  
Rubber  
Electrical  
Input Voltage  
5 VDC r 0.25V  
1275 mW  
600 mW  
255 mA @ 5VDC  
120 mA @ 5VDC  
Class 2; 5VDC @ 450 mA  
UL, FCC Class A  
Power - Operating  
Power - Standby  
Current - Operating  
Current - Standby  
DC Transformers  
Agency listing  
Environmental  
Operating Temperature  
0q to 45qC (32qF to 113qF)  
-40qC to 60qC  
Storage  
(-40qF to 140qF)  
5% to 90% relative humidity,  
non-condensing  
Up to 60000 Lux  
1.5m drop onto concrete  
Seals to resist airborne particulate  
contaminants  
Humidity  
Light Level  
Shock  
Contaminants  
Ventilation  
None required  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Default Setting for each barcode shown as below:  
Code Type  
Read  
Checksum  
Verifacation Transmission  
Checksum  
Code ID  
UPC-A  
UPC-E  
EAN-13  
EAN-8  
Code-39  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
A
E
F
FF  
*
Interleaved 2of5  
X
i
Industrial 2of5  
Matrix 2of5  
Standard 2of5  
China Post  
Codabar  
i
B
i
t
%
#
Code-128  
X
X
Code-93  
Code-11  
MSI/Plessey  
UK/Plessey  
Telepen  
&
O
@
@
S
Italian Pharmaode.  
p
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming  
Manual (Reading special barcode) DOS  
command through RS-232, Windows  
configuration program  
Programming  
method  
Program upgrade Enabled by built-in flash memory  
Code type selection, check digit  
selection Decoding option Decoding  
option Transmitted character delay,  
Header selection, trailer selection,  
message suffix, good read beep tone  
and volume, scanner trigger selection  
Keyboard emulation type  
Programmable  
characteristics  
(intermessage delay, keyboard type  
and keyboard language)  
Serial interface type (ACK/NAK,  
Xon/Xoff, RTS/CTS, good read LED  
control, start/stop bits)  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming the  
LGZ7225  
To program the LGZ7225 you must scan a series of  
programming barcode in the correct order. Fold out the back  
cover of this manual. You will see a table of alphanumeric  
barcodes, which are used to program the various options  
presented.  
To program each option, you must:  
1. Scan the Program barcode on the parameter setting part.  
2. Enter the option mode by scanning the Option Bar Code  
(also on the Parameter setting part).  
3. To the right of the option barcode, the necessary  
alphanumeric inputs are listed. Scan these alphanumeric  
entries from the back fold out page. To confirm above  
steps, you must scan the Finish barcode on the back fold  
out page.  
4. Once you have finished programming. Scan the Exit  
barcode, listed on the lower right hand corner of each  
parameter setting part.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program Barcode  
Program  
Option Bar Code  
Option  
Alphanumeric Entry  
Keyboard Wedge  
RS-232  
00  
01  
Interface  
selection  
Wand emulation  
USB  
02  
03  
Keyboard/RS-232  
Auto detection  
reserved  
04  
05  
Exit  
Option Barcode  
Back Fold Out  
Exit Barcode  
Finish barcode  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interface Selection  
This decoder built-in scanner comes in one model and  
supports interfaces such as keyboard wedge, RS232 serial  
wedge, wand emulation, and the latest USB interface. In  
most of the cases, simply sutilizing the an appropriate cable with  
a device code will work for a specific interface.  
Interface selection: You can change factory interface  
default for other type interface. By plugging different cables,  
setting correct interface, then the scanner will be changed to  
another interface. However, you must make sure which cable  
you need.  
Keyboard/RS232/UBS Auto detection: By setting this  
function, it will automatically select the Keyboard wedge or  
RS-232 or UBS interface for user.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Keyboard Wedge  
RS-232  
00  
01  
02  
03  
Interface selection  
Wand emulation  
USB  
Keyboard  
/RS232/USB  
Auto detection  
Reserved  
04  
05  
Note:-Default  
Exit  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keyboard wedge  
As a keyboard interface, the scanner supports most of the  
popular PCs and IBM terminals. The installation of the wedge  
is a fairly simple process without any changes of software or  
hardware.  
Keyboard Type: Select keyboard type connector of your  
host computer. Scanner must be selected to the appropriate  
host interface cable converter.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
IBM AT, PS/2  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
00ഖ  
01  
Keyboard type  
02  
03  
04  
05  
06  
Exit  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keyboard wedge  
Keyboard Layout: The selecting of keyboard layout  
supports many country languages other than USA keyboard  
layout. First you need to confirm country language that you  
desire. In DOS, using command “keyb” to select the  
desirable keyboard layout or in WINDOWS entry “Control”  
then pops “Keyboard” to select country at “language” item.  
For details, please refer to your DOS or WINDOWS user’s  
manual.  
Keyboard Speed: By selecting, you can change output  
speed of scanner to match with host computer. Generally, set  
00 or 01 in working high speed. If some output characters of  
barcode have been lost, you may need to set 05 or 06 to  
match your host keyboard speed.  
Function Key: Set Enable, scanner can output code as  
pressing function-key in your application program while the  
barcode datas contain ASCII value between 0116 to 1F16.  
Refer to ASCII table, page 94.  
Numeric Key: The Keypad has to be selected if your  
application program is only keypad numeric code acceptable.  
So, scanner will output code as press numeric keypad when  
it read numeric digit. (The keypad is in the right side of  
keyboard, and Num Lock control key is also on.) If  
Alt+Keypad is selected, Caps Lock and output will be  
independent.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USA  
00ഖ  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
Belgium  
Danish  
Keyboard layout  
France  
Germany  
Italian  
Portuguese  
Spanish  
Swedish  
Switzerland  
UK  
Latin American  
0-8  
00-08  
0 : high clock rate  
8 : low clock rate  
Disable  
01  
Keyboard speed  
Function key  
Numeric key  
00  
Enable  
01ഖ  
Alphabetic key  
Numeric keypad  
(Num lock state  
only)  
00ഖ  
01  
Alt+Keypad  
02  
Exit  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Keyboard wedge  
Caps Lock: By selecting Caps Lock or No Caps Lock,  
scanner can get Caps Lock status.  
Power-on simulation: All of the PCs check the keyboard  
status during power-on selftest. It is recommended to Enable  
function if you are working without keyboard installation. It  
simulates keyboard timing and pass keyboard present status  
to the PC during power-on.  
Inter-character delay: This delay is inserted after each data  
characters transmitted. If the transmission speed is too high,  
the system may not be able to receive all characters. Adjust it  
and try out suited delay to make system work properly.  
Block transmission delay: It is a delay timer between  
barcode data output. The feature is used to transfer  
continually with shorter barcode data or multi-field scanning.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Caps lock”ON”  
Caps lock”OFF”  
01ഖ  
Caps lock  
Disable  
Enable  
00ഖ  
01  
Power-on simulation  
Inter-character delay  
00-99 msec  
00-99  
02ഖ  
00-99 10 msec  
00-99  
10ഖ  
Block transmission  
delay  
Exit  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232  
CTS: Clear To Send (Hardware Signal)  
RTS: Request To Send (Hardware Signal)  
Xon: Transmit On (ASCII Code 1116)  
Xoff: Transmit Off (ASCII Code1316)  
Flow control:  
None-The communication only uses TxD and RxD signals  
without regard for any hardware or software handshaking  
protocol.  
RTS/CTS-If the scanner wants to send the barcode data to  
host computer, it will issue the RTS signal first, wait for the  
CTS signal from the host computer, and then perform the  
normal data communication. If there is no replied CTS signal  
from the host computer after the timeout (Response Delay)  
duration, the scanner will issue a 5 warning beeps.  
Xon/Xoff- When the host computer is unable to accept data,  
it sends a Xoff code to inform the scanner to suspend data  
transmission, and Xon to continue.  
ACK/NAK- When the ACK/NAK protocol is used, the  
scanner waits for an ACK (acknowledge) or (not  
acknowledge) from the host computer after data transmission,  
and will resend in response to a NAK.  
Inter-character delay: It is delay time between data  
character’s data output. It is also same as Inter-char. delay of  
keyboard wedge.  
Block transmission delay: It is a delay time between  
barcode data output. It is also same as Block transmission  
delay of keyboard wedge.  
Response delay: This delay is used for serial  
communication of the scanner to waiting for handshaking  
acknowledgment from the host computer.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
None  
00ഖ  
01  
RTS/CTS  
Xon/Xoff  
ACK/NAK  
00-99 (msec)  
Flow control  
02  
03  
00-99  
00ഖ  
Inter-character delay  
00-99 (10 msec)  
00-99 (100 msec)  
00-99  
00ഖ  
Block transmission  
delay  
00-99  
20ഖ  
Response delay  
Exit  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
300 BPS  
600 BPS  
1200 BPS  
2400 BPS  
4800 BPS  
9600 BPS  
19200 BPS  
38400 BPS  
None  
00  
01  
Baud rate  
02  
03  
04  
05ഖ  
06  
07  
00ഖ  
01  
Odd  
Parity  
Even  
02  
8 bits  
00ഖ  
01  
7 bits  
Data bit  
Stop bit  
One bit  
00ഖ  
Two bits  
01  
Exit  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wand Emulation  
Bar/space polarity:  
High/low- Black will be transmitted as a high voltage level  
(+5) and space as low level (0V).  
Low/high- Black will be transmitted as a low voltage level  
(0V) and space as high level (+5).  
Initial polarity: You must make sure what is Initial polarity of  
your wand decode device in stand-by (idle). So, initial signal  
state as a High voltage level (+5) or Low voltage level (0V).  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
High/low  
00ഖ  
Low/high  
01  
Bar/space polarity  
Initial polarity  
Low  
00ഖ  
High  
01  
Exit  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wand Emulation  
Output speed: This setting is same as serial transmission  
baud rate, and it must be approbated your wand decode  
resolution. The unit of speed is a width of minimum narrow  
bar.  
Margin delay: It is a timer of zone like space zone of  
barcode label margin. The width of margin time will be added  
before and after in each barcode data automatically when it  
is transmitted.  
Transmit delay: It is a delay time between barcode data  
output. It is the same as Block transmission delay of  
keyboard wedge.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
620 pps  
00  
1250 pps  
2500 pps  
5000 pps  
10000 pps  
20000 pps  
*pps: pixel per  
second  
01  
02  
Output speed  
03ഖ  
04  
05  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
00ഖ  
Reserved  
00ഖ  
Reserved  
00-99 (10 pixel)  
00-99 (10 msec)  
00-99  
15ഖ  
Margin delay  
Transmit delay  
00-99  
30ഖ  
Exit  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scan  
Scanning mode:  
Good-read off-The trigger button must be pressed to  
activate scanning. The light source of scanner stops  
scanning when there is a successful reading or no code is  
decoded after the Stand-by duration elapsed.  
Momentary-The trigger button acts as a switch. Press button  
to activate scanning and release button to stop scanning.  
Alternate-The trigger button acts as a toggle switch. Press  
button to activate or stop scanning.  
Timeout off-The trigger button must be pressed to activate  
scanning, and scanner stops scanning when no code is  
decoded after the Stand-by duration elapsed.  
Continue-The scanner always keeps reading, and it does  
not matter when trigger button is pressed or duration is  
elapsed.  
Same Barcode delay time: If the barcode has been  
scanned twice, then only the first barcode will be accepted.  
Double confirm: If it is enabled, the scanner will require a  
several times successful decoding to confirm the barcode  
data. The more confirming times required the more inhibitive  
miss-reading code will be shown. If you set Double confirm,  
the Multi field scan Enable function won’t be able to work.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Good-read off  
Momentary  
Alternate  
00  
01ഖ  
02  
Scanning mode  
Timeout off  
Continue  
03  
04  
01-99 (second)  
00-99  
10ഖ  
Stand-by duration  
01-99 (10 msec)  
01-99  
50ഖ  
Same barcode delay  
time  
00-99  
00-09  
(00: no double  
confirm)  
00ഖ  
Double confirm  
Exit  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scan  
Multi field scan: The scanner can be read many sets of  
barcode data on the same scanning line at the same time,  
even if they are different kinds of barcode symbology.  
Global min./max. code length: Global Minimum and  
Maximum length can be set to qualify data entry. The length  
is defined as the actual barcode data length to be sent. Label  
with length exceeds these limits will be rejected. Make sure  
that the Minimum length setting is no greater than the  
Maximum length setting, or otherwise the labels of the  
symbology will not be readable. In particular, you can set the  
same value for both Minimum and Maximum reading length  
to force the fixed length barcode decoded. The values of  
setting have no effect on certain symbologies with fixed  
length.  
Notes 1): Please set the min/max length if you have special  
demand for individual barcode.  
2): Include the Check sum digits if you want to set  
Global min/max code length.  
Inverted image scan:. Set Enabled the scanner will scan  
both black/white barcode with white/black background.  
CTS trigger: This operation enabled an external device to  
control scanning. The CTS trigger is controlled by apply an  
external trigger signal to the CTS input. When active, this  
signal causes scanning to begin as the scanner’s trigger was  
depressed.  
Position indication: This function can indicate the specific  
location before scanning. You can also set up the time of  
indication(except AS-8110).  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00ഖ  
01  
Multi field scan  
00-63  
00-63  
00-63  
04ഖ  
Global min. code length  
Global max.code length  
Inverted image scan  
CTS trigger  
04-63  
63ഖ  
Disable  
Enable  
00ഖ  
01  
Disable  
Enable  
00ഖ  
01  
Disable  
00ഖ  
01  
30 second  
60 second  
90 second  
120 second  
150 second  
180 second  
Continue  
Position indication  
02  
03  
04  
05  
06  
07  
Exit  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Indication  
Exit  
Power on alert: After power-on the scanner it will generate  
an alert signal to indicate a successful self-test.  
LED indication: After each successful reading, the LED  
above the scanner will light up to indicate a good barcode  
reading.  
Buzzer indication: After each successful reading, the  
scanner will beep buzzer to indicate a good barcode reading,  
and its Beep loudness, Beep tone freq. and Beep tone  
duration are adjustable.  
Beep loudness/Beep tone freq./Beep tone duration: You  
can adjust Beep Loudness, Beep tone and Beep duration for  
a good reading upon favorite usage.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Disable  
Enable  
01ഖ  
Power on alert  
LED indication  
Buzzer indication  
Beep loudness  
Beep tone freq.  
Beep tone duration  
Disable  
Enable  
00  
01ഖ  
Disable  
Enable  
00  
01ഖ  
00-07  
00-07  
07ഖ  
00-99 (100Hz)  
00-99 (10 msec)  
00-99  
26ഖ  
00-99  
10ഖ  
Exit  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UPCA  
Read: Format  
Leading  
Zero  
Data Digits  
(11 Digits)  
Check  
Digit  
Check-sum transmission: By setting Enable, checks sum  
will be transmitted.  
Truncate leading/ending: The leading or ending digits of  
barcode data characters can be truncated when these values  
are set to non-zero. It will beep instead of reading anything  
when the truncate value is more than the barcode data digits  
or the value of Truncate Leading is overlapped with that of  
the Ending. The maximum value of truncate digits is 15.  
Code ID setting: Code ID setting is a character used to  
represent the symbol upon a succeeding reading. A Code ID  
setting is prefixed to the data begin or end transmitted if the  
feature is selected. If you want application to transmit Code  
ID, you must set Code ID transmission to Enable first. Refer  
to Code ID transmission.  
Insertion group selection: The scanner offer one or two  
insertion group for own symbology. By setting one or two  
digits to indicate which insertion group you want to insert.  
You may refer to Character insertion.  
Example: Group 2  set 02 or 20.  
Group 1 and 4  set 14 or 41.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Disable  
Enable  
01ഖ  
Read  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00  
01ഖ  
Check-sum verification  
Check-sum transmission  
Max.code length  
Disable  
Enable  
00  
01ഖ  
00-64  
00-64  
0-15  
00-64  
64ഖ  
00-64  
01ഖ  
Min.code length  
00-15  
00ഖ  
Truncate leading  
0-15  
00-15  
00ഖ  
Truncate ending  
00-ffH ASCII 00-ffH  
code  
< A >ഖ  
Code ID setting  
00-44  
00-44  
00ഖ  
Insert group selection  
Exit  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UPCA  
Supplement digits: The Supplement digits barcode is the  
supplemental 2 or 5 characters for WPC code.  
Format  
Supplement Digits  
Leading Data Digits Check  
2 or 5 or  
Zero  
(11 Digits) Digit  
UCC / EAN 128  
Truncate Leading zero: The leading “0” digits of UPCA data  
characters can be truncated when the function is enabled.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
None  
00ഖ  
01  
2 digits  
5 digits  
Supplement digits  
02  
UCC/EAN 128 03  
Auto detection 04  
Disable  
Enable  
00  
01ഖ  
Truncate Leading zero  
The  
Exit  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UPCE  
Read: Format  
Leading  
Zero  
Data Digits (6  
Digits)  
Check  
Digits  
Check-sum verification: The checksum of EAN-13 is  
optional and made as the sum of the numerical value of the  
data digits.  
Check-sum transmission: By setting Enable, checks sum  
will be transmitted.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Disable  
Enable  
01ഖ  
Read  
Disable  
Enable  
00  
01ഖ  
Check-sum  
verification  
Disable  
Enable  
00  
01ഖ  
Check-sum  
transmission  
Exit  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UPCE  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Supplement digits:  
Format  
Supplement Digits  
Leading  
Zero  
Data Digits Check  
(6 Digits) Digit  
2 or 5 or  
UCC/EAN 128  
Truncate Leading zero: Refer to Truncate Leading zero of  
UPCA.  
Expansion: The expansion function is used only for UPCE  
and EAN-8 code reading. It extends to 13-digits with “0” digits  
when the feature is enabled.  
Example: Barcode “0123654”  
Output: “0012360000057”  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
0-15  
00-15  
00ഖ  
Truncate leading  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
0-15  
00-15  
00ഖ  
Truncate ending  
Code ID setting  
00-ffH ASCII  
code  
00-ffH  
< E >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
None  
00ഖ  
01  
2 digits  
Supplement digits  
5 digits  
02  
UCC/EAN 128  
Auto detection  
Disable  
03  
04  
00ഖ  
Enable  
01  
Truncate Leading  
zero  
Disable  
Enable  
00ഖ  
01  
Expansion  
Exit  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAN-13  
Read: Format  
Data Digits (12 Digits)  
Check Digits  
Check-sum verification: The checksum of EAN-13 is  
optional and made as the sum of the numerical value of the  
data digits.  
Check-sum transmission: By setting Enable, checks sum  
will be transmitted.  
Max./Min. code length: Each symbology has own Max./Min.  
Code Length. They can be set to qualify data entry. If their  
Max./Min. Code Length is zero, the Global Min./Max. Code  
Length is in effect. The length is defined as to the actual  
barcode data length to be sent. Label with length exceeds  
these limits will be rejected. Make sure that the Minimum  
length setting is no greater than the Maximum length setting,  
or otherwise all the labels of the symboblogy will not be  
readable. In particular, you can see the same value for both  
Minimum and Maximum reading length to force the fixed  
length barcode decoded.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Program  
The  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Disable  
Enable  
01ഖ  
Read  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00  
01ഖ  
Check-sum  
verification  
Disable  
Enable  
00  
01ഖ  
Check-sum  
transmission  
00-64  
00-64  
0-15  
00-64  
64ഖ  
Max.code length  
Min.code length  
Truncate leading  
Truncate ending  
00-64  
01ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
Exit  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAN-13  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Supplement digits:  
Format  
Supplement Digits  
2 or 5 or  
Data Digits  
(12 Digits)  
Check  
Digits  
UCC / EAN 128  
ISBN/ISSN: The ISBN (International Standard Book Number)  
and ISSN (International Standard Serial Number) are two  
kinds of barcode for book and magazines. The ISBN is 10  
digits with leading “978” and the ISSN is 8 digits with leading  
“977” of the “EAN-13” symbobolgy.  
Example: Barcode “9789572222720” - Output: “9572222724”  
Example: Barcode “9771019248004” - Output: “10192484”  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00-ffH ASCII  
code  
00-ffH  
< F >ഖ  
Code ID setting  
00-44  
00-44  
00ഖ  
Insert group  
selection  
None  
00ഖ  
01  
2 digits  
Supplement digits  
5 digits  
02  
UCC/EAN 128  
Auto detection  
Disable  
03  
04  
00ഖ  
Enable  
01  
ISBN/ISSN  
conversion  
Exit  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAN-8  
Read: Format  
Data Digits  
(7 Digits)  
Check  
Digits  
Check-sum verification: The checksum of EAN-8 is  
optional and made as the sum of the numerical value of the  
data digits.  
Check-sum transmission: By setting Enable, checks sum  
will be transmitted.  
Max./Min. code length: Refer to Max./Min. code length of  
EAN-13.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Disable  
Enable  
01ഖ  
Read  
Disable  
Enable  
00  
01ഖ  
Check-sum  
verification  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00  
01ഖ  
Check-sum  
transmission  
00-64  
00-64  
0-15  
00-64  
64ഖ  
Max.code length  
Min.code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
01ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
Two characters  
00-ffH ASCII  
code  
00-ffH, 00-ffH  
< FF >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Exit  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EAN-8  
Supplement digits: Format  
Supplement Digits  
2 or 5 or  
Data Digits Check  
(7 Digits)  
Digits  
UCC/EAN 128  
Truncate Leading zero: Refer to Truncate Leading zero of  
UPCE.  
Expansion: Refer to Expansion of UPCE.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
None  
00ഖ  
01  
2 digits  
Supplement digits  
5 digits  
02  
UCC/EAN 128  
Auto detection  
Disable  
03  
04  
00ഖ  
Enable  
01  
Truncate Leading  
zero  
Disable  
Enable  
00ഖ  
01  
Expansion  
Exit  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code 39  
Read: Format  
Start  
Data Digits Checksum  
( Variable) (Optional)  
End  
”  
”  
Check-sum verification: The checksum of Code-39 is  
optional and made as the sum module 43 of the numerical  
value of the data digits.  
Check-sum transmission: By setting Enable, checksum  
and will be transmitted.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Disable  
Enable  
01ഖ  
Read  
Disable  
Enable  
00ഖ  
01  
Check-sum  
verification  
Disable  
Enable  
00ഖ  
01  
Check-sum  
transmission  
Exit  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code 39  
Max./Min. code length: Each symbology has own Max./Min.  
Code Length. They can be set to qualify data entry. If their  
Max./Min. Code Length is zero, the Global Min./Max. Code  
Length is in effect. The length is defined as to the actual  
barcode data length to be sent. Label with length exceeds  
these limits will be rejected. Make sure that the Minimum  
length setting is no greater than the Maximum length setting,  
or otherwise all the labels of the symboblogy will not be  
readable. In particular, you can see the same value for both  
Minimum and Maximum reading length to force the fixed  
length barcode decoded.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Format: The Full ASCII Code-39 is an enhanced set of  
Code-39 that is the data with total of 128 characters to  
represent Full ASCII code. It is combined one of the digits +,  
%, $ and/ with one of the alpha digits (A to Z).  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
00-64  
00-64  
0-15  
00-64  
00ഖ  
Max. code length  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
00ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
<>  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Standard  
00ഖ  
Full ASCII  
01  
Format  
Exit  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code 39  
Append: This function allows several symbols to be  
concatenates and be treat as one single data entry. The  
scanner will not transmit the embedded appending code  
(space for Code-39). If Enable and other symbols were read  
again with the appended code, then codes will be transmitted  
without Code ID, Preamble and Prefix. When a symbol was  
decoded without the appended code, the data will be  
transmitted without Code ID and Prefix, but the Postamble  
Suffix codes are appended. This function is used when the  
first number of code 39 is a space. Example: 123456.  
Start/end transmission: The start and end characters of  
Code-39 are“”. You can transmit all data digits including two  
”.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Append  
Disable  
Enable  
00ഖ  
01  
Start/end  
transmission  
Exit  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interleaved 2 of 5  
Read: Format  
Data Digits  
(Variable)  
Checksum  
(Optional)  
Check-sum verification: The checksum is made as the sum  
module 10 of the numerical values of all data digits.  
Check-sum transmission: By setting Enable, checksum  
and will be transmitted.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Disable  
Enable  
01ഖ  
Read  
Disable  
Enable  
00  
01ഖ  
Check-sum  
verification  
Disable  
Enable  
00ഖ  
01  
Check-sum  
transmission  
Exit  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interleaved 2 of 5  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00-64  
00-64  
00ഖ  
Max. code leading  
Min. code leading  
Truncate leading  
Truncate ending  
00-64  
0-15  
0-15  
00-64  
00ഖ  
00-15  
00ഖ  
00-15  
00ഖ  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
00-ffH ASCII  
code  
00-ffH  
< i >ഖ  
Code ID setting  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Exit  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Industrial 2 of 5  
Read: Format  
Data Digits  
(Variable)  
Checksum  
(Optional)  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
00-64  
00-64  
00ഖ  
Max. code length  
Min. code length  
00-64  
00-64  
00ഖ  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
0-15  
0-15  
00-15  
00ഖ  
Truncate leading  
Truncate ending  
Code ID setting  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< i >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Exit  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Matrix 2 of 5 Eur  
Read: Format  
Data Digits  
(Variable)  
Checksum  
(Optional)  
Checksum Verification: The checksum is made as the sum  
module 10 of the numerical values of all data digits.  
Checksum Transmission: By setting Enable, checksum  
and will be transmitted.  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
Disable  
Enable  
00ഖ  
01  
Checksum  
Verification  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00ഖ  
01  
Checksum  
Transmission  
00-64  
00-64  
0-15  
00-64  
00ഖ  
Max. code length  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
00ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< B >ഖ  
00-44  
00- 44  
00ഖ  
Insert group  
selection  
Exit  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Codabar  
Read: Format  
Start  
Data Digits (Variable) Checksum (Optional) End  
Checksum Verification: The checksum is made as the sum  
module 16 of the numerical values of all data digits.  
Checksum Transmission: By setting Enable, checksum  
and will be transmitted.  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00(8150/8210)  
Enable  
01(8110)  
Read  
Disable  
Enable  
00ഖ  
01  
Checksum  
Verification  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00ഖ  
01  
Checksum  
Transmission  
00-64  
00-64  
0-15  
00-64  
00ഖ  
Max. code length  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
00ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< % >ഖ  
Exit  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Codabar  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Start/End type: The Codabar has four pairs of Start/End  
pattern; you may select one pair to match your application.  
Start/End Transmission: Refer to Start/End Transmission of  
Code 39.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00-44  
00-44  
00ഖ  
Insert group  
selection  
ABCD/ABCD  
abcd/abcd  
ABCD/TN*E  
Abcd/tn*e  
Disable  
00ഖ  
01  
Start/End type  
02  
03  
00ഖ  
Enable  
01  
Start/End  
transmission  
Exit  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code-128  
Read: Format  
Data Digits  
(Variable)  
Checksum  
(Optional)  
Checksum Verification: The checksum is made as the sum  
module 103 of all data digits.  
Checksum Transmission: By setting Enable, checksum  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00  
Disable  
Enable  
01ഖ  
Read  
Disable  
Enable  
00  
01ഖ  
Checksum  
Verification  
Disable  
Enable  
00ഖ  
01  
Checksum  
Transmission  
Exit  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code-128  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Format: The Code-128 can be translated to UCC/EAN-128  
format if it starts with FNC1 character. The first FNC1 will  
be translated to “]C1”,and next to be a field separator code as  
<GS>(1D16).  
]C1  
Datas <GS> Datas Checksum  
Append: When the function is enabled, it won't show the  
data immediately if scanner read the barcode includes FNC2  
code. It will show all data until it read the barcode, which  
doesn't have FNC2 code.  
Field separator code: This feature is only used for  
UCC/EAN-128 format. This Field separator code means you  
can reassign second or after a FNC1 for your usage. The  
default of ASCII code is <GS>(1D16).  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
00-64  
00-64  
00ഖ  
Max. code length  
Min. code length  
00-64  
00-64  
00ഖ  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
0-15  
0-15  
00-15  
00ഖ  
Truncate leading  
Truncate ending  
Code ID setting  
Insert group selection  
Format  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< # >ഖ  
00-44  
00-44  
00ഖ  
Standard  
00ഖ  
UCC/EAN-128 01  
Disable  
Enable  
00ഖ  
01  
Append  
00-ffH ASCII  
code  
00-ffH  
< # >ഖ  
UCC/EAN-128  
ID setting  
00-ffH ASCII  
code  
00-ffH  
1DHഖ  
Field separator code  
Exit  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code-93  
Read: Format  
Data Digits Checksum1 Checksum2  
(Variable) (Optional) (Optional)  
Checksum Verification: The checksum is made as the sum  
module 47 of the numerical values of all data digits.  
Checksum Transmission: By setting Enable, checksum  
and will be transmitted.  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
Disable  
00  
Enable (two  
digits)  
01ഖ  
Checksum  
Verification  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00ഖ  
01  
Checksum  
Transmission  
00-64  
00-64  
0-15  
00-64  
00ഖ  
Max. code length  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
00ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< & >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Exit  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Code-11  
Read: Format  
Data Digits Checksum1 Checksum2  
(Variable) (Optional) (Optional)  
Checksum Verification: The checksum is presented as the  
sum module 11 of all data digits.  
Checksum Transmission: By setting Enable, checksum1  
and checksum2 will be transmitted upon your selected  
checksum verification method.  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
Disable  
00  
One digit  
Two digits  
01ഖ  
Checksum  
Verification  
02  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00ഖ  
01  
Checksum  
Transmission  
00-64  
00-64  
0-15  
00-64  
00ഖ  
Max. code length  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
00ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< O >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Exit  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MSI/plessey  
Read: Format  
Data Digits Checksum1 Checksum2  
(Variable) (Optional) (Optional)  
Checksum Verification: The MSI/Plessey has one or two  
optional checksum digits. The checksum is presented 3  
kinds of method Mod10, Mod10/10 and Mod 11/10. The  
checksum1 and checksum2 will be calculated as the sum  
module 10 or 11 of the data digits.  
Checksum Transmission: By setting Enable, checksum1  
and checksum2 will be transmitted upon your selected  
checksum verification method.  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
Disable  
00(8110)  
Mod 10  
01(8150/8210)  
Checksum  
Verification  
Mod 10/10  
Mod 11/10  
02  
03  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00ഖ  
01  
Checksum  
Transmission  
00-64  
00-64  
0-15  
00-64  
00ഖ  
Max. code length  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
00ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< @ >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Exit  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UK/plessey  
Read: Format  
Data Digits  
(Variable)  
Checksum1+2  
(Optional)  
Checksum Verification: The UK/Plessey has one or two  
optional checksum digits. The checksum1 and checksum2  
will be calculated as the sum module 10 or 11 of the data  
digits.  
Checksum Transmission: By setting Enable, checksum will  
be transmitted.  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
Disable  
Enable  
00  
01ഖ  
Checksum  
Verification  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00ഖ  
01  
Checksum  
Transmission  
00-64  
00-64  
0-15  
00-64  
00ഖ  
Max. code length  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
00ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< @ >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Exit  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Telepen  
Read: IATA (International Air Transport Association).  
Checksum Verification: The checksum is presented as the  
sum module 10 or 11 of the data digits.  
Checksum Transmission: By setting Enable, checksum will  
be transmitted.  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
Disable  
Enable  
00ഖ  
01  
Checksum  
Verification  
Disable  
Enable  
00ഖ  
01  
Checksum  
Transmission  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
00-64  
00-64  
0-15  
00-64  
00ഖ  
Max. code length  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-64  
00ഖ  
00-15  
00ഖ  
0-15  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< S >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
1XPHULFꢀRQO\ꢀ  
ꢁꢁ  
)XOOꢀ$6&,,ꢀRQO\ꢀ  
ꢁꢂꢀ  
)RUPDWꢀ  
Exit  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Standard 2 of 5  
Read: Format  
Data Digits  
(Variable)  
Checksum1  
(Optional)  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
00-64  
00-64  
00ഖ  
Max. code length  
Min. code length  
00-64  
00-64  
00ഖ  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
0-15  
0-15  
00-15  
00ഖ  
Truncate leading  
Truncate ending  
Code ID setting  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< i >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Exit  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
China Post  
Read: Format  
Data Digits  
(Variable)  
Checksum1  
(Optional)  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
00-64  
00-64  
11ഖ  
Max. code length  
Min. code length  
00-64  
00-64  
11ഖ  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
0-15  
0-15  
00-15  
00ഖ  
Truncate leading  
Truncate ending  
Code ID setting  
00-15  
00ഖ  
00-ffH ASCII  
code  
00-ffH  
< t >ഖ  
00-44  
01-44  
00ഖ  
Insert group  
selection  
Exit  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Italian Pharmacode  
Read: Format  
Data Digits  
(Variable)  
Checksum1  
(Optional)  
Max./Min. code length: Refer to Max./Min. code length of  
Code-39.  
Truncate leading/ending: Refer to Truncate leading/ending  
of UPCA.  
Code Id setting: Refer to Code ID setting of UPCA.  
Insertion group selection: Refer to Insertion group  
selection of UPCA.  
Leading “A”: If this function is enabled, each prefix of data  
shall be A.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Read  
00-64  
00-64  
10ഖ  
Max. code length  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
00-64  
0-15  
0-15  
00-64  
09ഖ  
Min. code length  
Truncate leading  
Truncate ending  
Code ID setting  
00-15  
00ഖ  
00-15  
00ഖ  
00-ffH ASCII  
code  
01-ffH  
< p >ഖ  
00-44  
00-44  
00ഖ  
Insert group  
selection  
Disable  
Enable  
00ഖ  
01  
Leading “A”  
Exit  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
String setting  
Prefix characters: Up to 22 ASCII characters may be sent  
before data digits.  
Prefix  
Data Digits  
Suffix  
Suffix characters: Up to 22 ASCII characters may be sent  
after data digits.  
Preamble/ Postamble characters: They are appended to  
the data automatically when each barcode is decoded.  
Example:  
Add a prefix/suffix or preamble/postamble for all symbologies.  
In this example, you are sending a $ symbol as a prefix for all  
symbologies.  
Steps:  
1) Scan Programming and Prefix characters setting barcode.  
2) Use the ASCII code table to find the value of $24.  
3) Scan 2 and 4 from the barcode on the fold out back page.  
4) Scan Finish from the barcode on the fold out page.  
5) Scan Exit barcode.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Prefix characters  
setting  
None  
0Dഖ  
1-22 characters  
00-ffH ASCII  
code  
Suffix characters  
setting  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Preamble characters  
setting  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Postamble  
characters setting  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Insert G1 characters  
setting  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Insert G2 characters  
setting  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Insert G3 characters  
setting  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Insert G4 characters  
setting  
Exit  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
String setting  
Insert G1/G2/G3/G4 character setting: The scanner offer 4  
positions and 4 characters to insert among the symbol.  
Example: Barcode “1 2 3 4 5 6”.  
Output- Barcode “1 2 A B 3 4 C D 5 6”.  
Steps:  
1) Scan Programming and Insert G1 characters setting  
barcode.  
2) Use the ASCII code table to find the value of A41,B 42.  
3) Scan 4, 1 and 4, 2 from the barcode on the fold out back  
page.  
4) Scan Finish from the barcode on the fold out page.  
5) Repeat the same procedure in Insert G2 characters  
setting.  
6) Scan Exit barcode.  
7) Insert data group 1-4 position. Please refer to Chapter-  
Transmission, page 65 and in specific barcode that you  
want to use.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Insert G1 characters  
setting  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Insert G2 characters  
setting  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Insert G3 characters  
setting  
None  
00ഖ  
1-22 characters  
00-ffH ASCII  
code  
Insert G4 characters  
setting  
Exit  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transmission  
Preamble transmission: By setting Enable, Preamble will  
be appended before the data transmitted.  
Postamble transmission: By setting Enable, Postamble will  
be appended after the data is transmitted.  
Insert data group 1-4 position: The scanner offers 4  
positions to insert among the symbol. The position default  
value is “00” to indicate no character insertion. Beside, make  
sure insertion positions are not greater than the symbols;  
otherwise the insertion data is not effective.  
Code ID position: Upon your usage, the transmitting  
position of Code ID can be selected to place Before Code  
Data or After Code Data when it is transmitted.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
Enable  
01  
Preamble  
transmission  
Disable  
Enable  
00ഖ  
01  
Postamble  
transmission  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
00-64  
00-64  
(00: no insertion)  
00ഖ  
Insert data group 1  
position  
00-64  
00-64  
(00: no insertion)  
00ഖ  
Insert data group 2  
position  
00-64  
00-64  
(00: no insertion)  
00ഖ  
Insert data group 3  
position  
00-64  
00-64  
(00: no insertion)  
00ഖ  
Insert data group 4  
position  
Before code data  
After code data  
00ഖ  
01  
Code ID position  
Exit  
78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transmission  
Code ID transmission: If your application is needed to  
transmit Code ID, you must set this to Proprietary ID or AIM  
ID.  
Code length transmission: A number of data digits can be  
transmitted before the code data when Enable is selected.  
The total length of the barcode is the number of barcode data  
except Truncate Leading/Ending Digits. And the length is a  
number with two digits.  
Code name transmission: This function is to show  
unknown barcode symbologies that include all readable  
symbologies of the scanner. When Enable is selected,  
Code Name will be transmitted before code data, you will  
know what kind of barcode symbology is.  
Case conversion: Under the barcode, you can set the  
alphabet in either upper case or lower case.  
Program  
Option Bar Code  
Option  
Alphanumeric  
Entry  
Disable  
00ഖ  
01  
Proprietary ID  
AIM ID  
Code ID  
02  
transmission  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disable  
Enable  
00ഖ  
01  
Code length  
transmission  
Disable  
Enable  
00ഖ  
01  
Code name  
transmission  
Disable  
00ഖ  
01  
Upper case  
Lower case  
*For barcode  
data only  
Case conversion  
02  
Exit  
Format of barcode data transmission:  
Code  
Barcode  
data  
Prefix Name Preamble  
ID  
ID  
Postamble Suffix  
Length  
Insert groups  
80  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7HVWꢀ&KDUWꢀ  
CODABAR-PARA  
CODE-11 PARA  
CODE-39 PARA  
81  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PDF-417  
STANDRAD-25 PARA  
ꢃꢄꢅꢆꢇ  
EAN-8 PARA  
82  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTERLEAVED-25 PARA  
MATRIX 25 PARA  
MSI/PLESSEY PARA  
UPCA PARA  
UK/PLESSEY PARA  
83  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASCII Code Table 1RWHꢈꢀ   
ꢂꢀ  
   )RUꢀNH\ERDUGꢀZHGJHꢀRQO\ꢉ  
/ꢀ    +ꢀ  
ꢁꢀ  
1XOOꢀ  
8Sꢀ  
ꢁꢀ  
ꢂꢀ  
ꢁꢀ  
18/ꢀ  
62+ꢀ  
67;ꢀ  
(7;ꢀ  
(27ꢀ  
(14ꢀ  
$&.ꢀ  
%(/ꢀ  
%6ꢀ  
'/(ꢀ  
'&ꢂꢀ  
'&ꢊꢀ  
'&ꢋꢀ  
'&ꢆꢀ  
1$.ꢀ  
6<1ꢀ  
(7%ꢀ  
&$1ꢀ  
(0ꢀ  
ꢂꢀ  
)ꢂꢀ  
)ꢊꢀ  
)ꢋꢀ  
)ꢆꢀ  
)ꢅꢀ  
)ꢌꢀ  
)ꢄꢀ  
)ꢃꢀ  
)ꢇꢀ  
)ꢂꢁꢀ  
(VFꢀ  
)ꢂꢂꢀ  
)ꢂꢊꢀ  
&WUOꢍꢀ  
$OWꢍꢀ  
ꢊꢀ  
'RZQꢀ  
/HIWꢀ  
5LJKWꢀ  
3J8Sꢀ  
3J'Qꢀ  
ꢋꢀ  
ꢆꢀ  
ꢅꢀ  
ꢌꢀ  
ꢄꢀ  
ꢃꢀ  
%Vꢀ  
ꢇꢀ  
7DEꢀ  
+7ꢀ  
$ꢀ  
%ꢀ  
&ꢀ  
'ꢀ  
(ꢀ  
)ꢀ  
/)ꢀ  
68%ꢀ  
(6&ꢀ  
)6ꢀ  
+RPHꢀ  
(QGꢀ  
(QWHUꢀ  
,QVHUWꢀ  
'HOHWHꢀ  
97ꢀ  
))ꢀ  
&5ꢀ  
*6ꢀ  
62ꢀ  
56ꢀ  
6,ꢀ  
86ꢀ  
/ꢀ      +  
ꢊꢀ  
63ꢀ  
ꢎꢀ  
ꢋꢀ  
ꢁꢀ  
ꢂꢀ  
ꢊꢀ  
ꢋꢀ  
ꢆꢀ  
ꢅꢀ  
ꢌꢀ  
ꢄꢀ  
ꢃꢀ  
ꢇꢀ  
ꢈꢀ  
ꢆꢀ  
ꢅꢀ  
ꢌꢀ  
Cꢀ  
ꢄꢀ  
Sꢀ  
ꢁꢀ  
ꢂꢀ  
ꢊꢀ  
ꢋꢀ  
ꢆꢀ  
ꢅꢀ  
ꢌꢀ  
ꢄꢀ  
ꢃꢀ  
ꢇꢀ  
$ꢀ  
%ꢀ  
&ꢀ  
'ꢀ  
(ꢀ  
)ꢀ  
#ꢀ  
$ꢀ  
%ꢀ  
&ꢀ  
'ꢀ  
(ꢀ  
)ꢀ  
*ꢀ  
+ꢀ  
,ꢀ  
3ꢀ  
4ꢀ  
5ꢀ  
6ꢀ  
7ꢀ  
8ꢀ  
9ꢀ  
:ꢀ  
;ꢀ  
<ꢀ  
=ꢀ  
>ꢀ  
Dꢀ  
Eꢀ  
Fꢀ  
Gꢀ  
Hꢀ  
Iꢀ  
Tꢀ  
ಮꢀ  
Uꢀ  
ꢏꢀ  
ꢐꢀ  
ꢑꢀ  
Vꢀ  
Wꢀ  
Xꢀ  
Yꢀ  
ಪꢀ  
Jꢀ  
Kꢀ  
Lꢀ  
Zꢀ  
[ꢀ  
ꢒꢀ  
ꢓꢀ  
\ꢀ  
့ꢀ  
ꢍꢀ  
웍ꢀ  
ꢖꢀ  
-ꢀ  
Mꢀ  
]ꢀ  
ꢔꢀ  
.ꢀ  
/ꢀ  
Nꢀ  
Oꢀ  
옧ꢀ  
옂ꢀ  
ꢕꢀ  
 ꢀ  
!ꢀ  
"ꢀ  
웽ꢀ  
@ꢀ  
0ꢀ  
1ꢀ  
2ꢀ  
Pꢀ  
Qꢀ  
Rꢀ  
온ꢀ  
ᅘꢀ  
'(/ꢀ  
ꢉꢀ  
Aꢀ  
ꢗꢀ  
Bꢀ  
84  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parameter Setting List  
Program  
Barcode standard parameter setting list  
If you wish to display the current configuration of your  
LGZ7225, scanner over the host terminal/computer  
scan the Barcode standard parameter setting list  
bar code.  
Unique parameter list  
If you wish to display the unique parameter setting list, scan  
the unique parameter list bar code  
System parameter setting list  
If you wish to display the product information and revision  
number for your LGZ7225 scanner over the host  
terminal/computer, scan the System parameter setting list  
bar code.  
String setting list  
If you wish to display the string format list, scan the String  
setting list bar code.  
85  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Firmware version list  
If you wish to display the firmware version, scan the  
Firmware version list.  
WARNING: Default value initialization  
If you wish to return theLGZ 7225 to all the factory  
default settings, scan the Default value initialization bar code.  
Exit  
86  
Download from Www.Somanuals.com. All Manuals Search And Download.  
0
1
A
B
C
D
E
F
2
3
4
5
6
7
8
Finish  
9
87  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Navman GPS Receiver VHF 7200 User Manual
NETGEAR Network Router JWNR2010v3 User Manual
NeumannBerlin Microphone 1M 214 User Manual
NordicTrack Treadmill 831249950 User Manual
Omron Fitness Electronics HJ 112 User Manual
Omron Healthcare Thermometer MC 343 User Manual
Optimus Speaker 120 1751 User Manual
Panasonic Air Conditioner CS CE7HKEW User Manual
Panasonic Fax Machine KX PW55CL User Manual
Panasonic Webcam AWHE50HN User Manual