I. System Start-Up Information  
1. Read the installation and maintenance instructions as well as the recommended  
safety practices in this manual.  
2. Install Ductwork completely before operating collector:  
A.) Seal ductwork with silicone sealant or duct tape.  
B.) Have Dust Bin in place and sealed.  
3. Have licensed electrician wire Fan / Blower according to wire diagram on pg. 12  
in this owner’s manual.  
4. Have licensed electrician check current draw on motor with all gates open. Current  
draw should not exceed maximum motor amperage. (OAS is not responsible for  
damage to motors caused by improper installation, wiring or failure to follow these  
directions.)  
Caution  
The Direct Drive Fan / Blower makes the system top heavy!  
Use extreme care when setting the unit up!  
Warning  
Do not operate Fan / Blower unless Cyclone and Dust Bin  
are in place. Motor will over heat!  
Warning  
Check amperage draw during operation with (2) open 5” dia.  
blastgates (or smaller). Make certain amperage is not outside  
operating limit indicated on motor plate!  
Warning  
If amperage is too high - shut down immediately!  
(See troubleshooting section.)  
2
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. 2hp Dust Gorilla Configurations  
Caution:  
If exhaust air is vented outside you must provide make up / return air.  
Flue gases (carbon monoxide) can be drawn into the shop from furnaces,  
water heaters or other appliances.  
1. External Cartridge Filter - Silencer Included with Filter  
Cartridge Filter Media  
1 Pleated Spun-Bonded Cartridge Filter 39” / 95 Sq. Ft.  
Accredited, independent lab tested.  
Bathed in teflon-like coating for easy dust release.  
Captures 99.9% of Test Material from 0.2 - 2 microns.  
1. External  
Cartridge  
Filter  
2hp and Under Systems  
13” Diameter Filter  
Silencer  
included  
1. Carefully pull  
Silencer up over the  
flange end until  
black plastic top  
meets flange plate.  
It is a tight fit.  
w/ Filter  
2. Slide Filter up to  
meet Flange  
Plate. Fasten  
bottom brace to  
rod to hold Filter.  
Follow Pg. 9 in Owner’s Manual to Complete Installation.  
Shown with  
optional  
Angle Iron  
Stand.  
3
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III. General Specifications & Fan Performance Curves  
Height without  
Dust Bin  
Cyclone  
Diameter  
Inlet  
Diameter  
Weight without  
Dust Bin  
TEFC  
*
Motors  
Class F  
Approx. Wt.  
122 lbs.  
w/o drum or filter  
115/230v  
63”  
21”  
7”  
23/11.5 amps  
1.15 Service Factor  
- Sleeve kit adds 7” (4” is minimum)  
- 35 gal. bin is 22” dia. x 22.5” h / 55 gal. bin is 22” dia. x 35.5” h  
- Several Filter Options Available- Galvanized steel construction  
- The collector can be hung on the wall, from the ceiling, or free standing support using  
the 10 ga. angle iron ring at the top of the cone.  
(See assembly instructions)  
2hp Super Dust Gorilla System  
* Note: Motor Starter supplied  
with system is for 220v only.  
1422 CFM @ 2.3” SP w/c w/o filter  
Industrial Baldor TEFC 2hp motor*  
115/230v - 23/11.5 amps / 1.15 Service Factor  
Full 16 gauge galvanized cyclone & 11 ga. fan housing  
7” dia. inlet / 8” rectangular outlet  
14.25” dia. x 4” wide cast aluminum fan wheel  
back inclined non-sparking, non-ferrous dynamic, two-planed  
balanced to ISO 6.3 specifications.  
Sound 78 - 79dB @ 10’ with Built-in Silencer and Filter  
95 Sq. Ft. Filter Media / Spun-Bonded  
Static pressure and volume together determine  
a fan’s performance. Several factors, such as  
layout of ductwork and diameter of openings,  
can affect a fan’s performance.  
2hp Super Dust Gorilla CFM vs. SP Curve*  
11  
10  
10.65  
9
8
7
6
5
4
3
2
0
9.4  
8.25  
6.3  
4.3  
1422 cfm @  
2.3” SP w/c  
w/o filter.  
Vented outside.  
1349 cfm @ 2.3”  
SP w/c w/ filter.  
FCS133900  
- Without Filter  
- With Filter  
3
2.3  
*Fan curves vary slightly with different filter packages.  
0
200  
400  
600  
800  
1000  
1200  
1400  
1600  
CFM  
4
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV. Dimensions  
For Minimum Mounting Heights w/ 39” Filter.  
*Dimensions subject to slight variation in manufacturing.  
42.5  
24.25  
26.34  
13.00  
Allow 1 - 2” from ceiling.  
8.00  
TM  
The  
7.00  
GORILLA  
13.00  
39.00  
16.00  
91.00  
75.50  
66.50  
56.00  
6.00  
35 Gal Shown  
Add 13" for 55 Gal  
Dimensions shown with  
2" flex hose between  
drum and cone collars  
5
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Motor Assembly - BXI002105  
1a. 2 hp Motor - BMZ020105  
XGK020105  
V. General Assembly  
1b. Magnetic Starter w/ Remote Option - AMR221114  
1c. Cord Connector - WCC025038  
1d. Cord Connector Lock Nut - WCN120000  
1e. Fan Wheel - BWX142578  
Caution:  
1a  
1f. Motor Plate - RMP002105  
If exhaust air is vented outside you must provide  
make up/return air.  
Flue gases (carbon monoxide) can be drawn into  
the shop from furnaces, water heaters or other  
appliances.  
(4) 3/8” x 1” Bolts  
(4) 3/8” Washers  
(4) 3/8” Nuts  
(8) 5/16” Washers  
(8) 5/16” Nuts  
2. Fan Housing - BHX030005  
3. Cyclone Barrel - SXI002105  
For All  
Systems  
Read Before Installing and Operating!  
Caution  
To  
avoid personal injury or property damage, read owner’s manual thoroughly before  
installing and operating system. (Read section on collector location and fire hazards.)  
This collector is for use with WOOD DUST ONLY!  
1f  
Keep fire extinguishers handy at all times.  
Do not use this product to collect other types of dusts or fumes.  
(Fire or explosion may occur!)  
Do not introduce sparks or sources of ignition into collector.  
Personnel should stay at least 20 ft. away from operating system. (Deflagration Hazard)  
Empty and check dust bin frequently for possible smoldering materials.  
Rotating blades inside. Keep hands and objects away.  
Do not operate system unless COMPLETELY assembled with dustbin.  
(Personal injury or motor damage may occur!)  
Consult local fire marshal before installing.  
Follow all Federal, State, Local and NFPA codes when installing system.  
To reduce the risk of injury from moving parts unplug before servicing.  
-
To reduce the risk of electric shock  
-
unplug before cleaning or servicing.  
4. Cyclone Cone - SCX002105  
5. Plenum 9” Kit - GXF015339  
5jh  
1e  
5a  
5a. Plenum Elbow 8” Assembly - FPX015339  
5b. Filter Support Rod (2) - YSS000200  
5c. 5/16” Connector 18 x 7/8” - VRH051618 (1)  
5d. Filter Support Brace - RBX000000  
5e. Washer - AFW170000  
2
5jh  
5g  
(8) 5/16” Washers  
(8) 5/16” Nuts  
5f. Thumb Nut - AFT000001  
5g. Internal Silencer (Pat. Pend.) - BSC130000  
5h. Dust Pan - RFG130805  
5i. Dust Clips (3) - AFC000000  
5j. Hardware Kit - AHX000000  
3
6
From Included  
Hardware  
(12) 5/16” x 1 1/4” Bolts  
(12) 5/16” Washers  
(12) 5/16” Nuts  
(3) 3/8” x 1 1/4” Bolts  
(3) 3/8” Washers  
(3) 3/8” Nuts  
5jh  
a. (3) 3/8 x 1 1/4” Bolts - AFS015700  
b. (14) 3/8” Washers - AFW190000  
c. (7) 3/8” Wiz Nuts - AFT00004  
d. (4) 3/8” x 1” Bolts - AFS015100  
e. (12) 5/16” x 1” Bolts Prewelded - AFB155190  
f. (24) 5/16” Washers - AFW180000  
g. (28) 5/16” Nuts AFT155175  
5c  
5b  
4
7
h. Gasket (25’) RAZ000000  
5d  
5k. Owner’s Manual - ZBM000013  
5e  
6. Filter 13” dia. x 39” L - FCS133995  
7. Wall Bracket - SMS300021  
5f  
16b  
16c  
16b  
5h  
8. Decal - (1) Oneida Logo - ZBC000015  
9. Decal - (1) Gorilla Logo - ZBC990020  
10. Rotation Label - ZBC000029  
11. Caution / Exhaust Label - ZBS000004  
12. General Caution Label - ZBS000001  
13. Filter Maintenance Label - ZBS000007  
14. Caution / Check Frequently Label - ZBS000006  
15. Caution / Drum Cover Label - ZBS000005  
5i  
16a  
Filter Maintenance  
Failure to follow filter maintenance instructions  
in owner’s manual will cause filter to be  
damaged.  
16d  
Blow down filter at end of day with compressed  
air per owner’s manual or blow down when back  
pressure reaches 3” water gauge whichever  
-
comes first. Never allow gauge to reach 5”.  
Caution  
8
9
Check Dust Bin Frequently For  
Smoldering Materials. Empty Bin Before  
Leaving Shop.  
Caution  
Drum cover must be in place when system  
is operating to prevent motor overheating!  
16. Gal. Fiber Drum Kit (Standard) - SDK350901  
16a. Drum Lid w/ 9” Ring - SDX000900  
16b. Hose Clamp (2) - ACB120000  
16c. Flex Hose (9”) - DHF090000  
TM  
An airtight seal between the cyclone and  
drum will provide the necessary resistance  
needed to prevent motor overheating!  
The  
GORILLA  
16d. 35 Gal. Fiber Drum - SDS350000  
17. 55 Gal. Fiber Drum Kit - SDK550901  
17a. Drum Lid w/ 9” Ring - SDX000900  
17b. Hose Clamps (2) - ACB120000  
17c. Flex Hose (9”) - DHF090000  
Optional Angle Iron Stand  
Stand - Hardware Kit -  
34a. Optional 35 gal. Angle Iron Stand - STG021035  
1.Uprights - SXX000056 (4)  
AHX021023  
A. (32) AFB155190 -  
5/16” Bolts  
2. Braces - SXX000021 (4 / SXX000023 (3)  
3. Feet - STX002001 (4)  
34b. Optional 55 gal. Angle Iron Stand - STG021055  
1. Uprights - SXX000068 (4)  
B. (32) AFT155175 -  
5/16” Wiz Nuts  
17d. 55 Gal. Fiber Drum - SDS550000  
18. 55 Gal. Steel Drum Kit - SEK550901  
18a. Drum Lid w/ 9” Ring - SEX550900  
18b. Hose Clamps (2) - ACB120000  
18c. Flex Hose (9”) - DHF090000  
C. (64) AFW180000 -  
5/16” Flat Washers  
2. Braces - SXX000021 (7)  
3. Feet - STX002001 (4)  
18d. 55 Gal. Steel Drum - SES550000  
6
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Do NOT use hook on motor to lift unit.  
VI. General Assembly Instructions  
There are essentially three ways to assemble your collector  
Gasket Material -  
Outside of  
Motor  
and to attach it to the bracket. The way that is right for you  
1.  
& Plate  
Bolt Circle on top  
of Housing.  
should be determined by expertise and manpower available.  
TOP  
When the units are all assembled they are very heavy and top  
weighted. All of this should be taken into account before  
deciding on the method best suited for you.  
To further eliminate  
air leaks, a small  
amount of silicone  
should be used on  
nuts used to  
Fan /  
Blower  
Housing  
With all assemblies, make sure  
rectangular air outlet is oriented on  
secure motor plate.  
Air  
Outlet  
Fan/Blower housing as you are  
TOP  
looking down as in Fig. 1A or facing  
VIEW  
Air Inlet  
it as shown in diagrams. This is very  
Gasket  
important. Then you can rotate  
Material -  
Outside of  
Bolt Circle  
on underside  
of Housing.  
Silicone nuts.  
housing to whatever bolt position is  
Fig. 1A  
TM  
The  
best for your shop.  
Cyclone  
Barrel  
GORILLA  
Before you start, make sure you have cut and placed  
the provided gasket material on top and bottom of the  
Fan/Blower housing and the Cone as shown in the  
diagrams. Then determine which direction you want  
your filter to hang and which direction your ductwork  
will enter the collector.  
2.  
TOP  
Method #1 -  
Bolt Fan/Blower housing to Cyclone barrel. Then bolt  
Motor and Plate to Fan/Blower housing. Carefully lay  
unit on its side and then bolt cone to barrel. Lift entire  
unit up onto wall braket. Unit is extremely heavy and  
top weighted, be advised!  
Gasket  
Material  
TM  
The  
Method #2 -  
GORILLA  
Cyclone  
Barrel  
Bolt Fan/Blower housing to Cyclone barrel. Then bolt  
Motor and Plate to Fan/Blower housing. Put Cone up  
on Wall Bracket and orient holes. Lift assembled unit  
onto cone making sure proper holes are lined up. Bolt  
unit to bracket, then finish bolting barrel to cone.  
Gasket  
(12) 3/8” Bolts  
(24) Flat Washers  
(12) Serrated Nuts  
Material -  
Inside of  
Bolt Circle  
Method #3 -  
Bolt  
Washer  
Flange  
Bolt Fan/Blower housing to Cyclone barrel. Put Cone  
up on Wall Bracket and orient holes. Lift assembled unit  
onto cone making sure proper holes are lined up. Bolt  
unit to bracket, then finish bolting barrel to cone. Lift  
Motor & Plate onto Fan/Blower housing and bolt together  
in proper direction.  
Cyclone  
Cone  
Washer  
Nut  
4.  
3.  
3/8” Bolt / (2) Washers /  
Serrated Nut per bolt hole  
on each side and back.  
Collector  
Hose Clamp  
TM  
The  
GORILLA  
Flex Hose  
Hose Clamp  
Dust Bin  
Note: For cyclonic preseparation there must be an air tight seal between cyclone and dust  
container. Dust bin must be located vertically under cyclone, material drops down by gravity.  
7
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. Bracket Assembly  
1. You must determine the direction the fan outlet will point to  
proceed with this mounting assembly. The collector will seem  
quieter if the outlet is aimed away from the area people tend to  
work. Slots in the brackets are .406” x 1.00”  
Note: Bolts included to mount bracket to collector. Hardware  
NOT included to mount to wall.  
1
24.25”  
16”  
.406” x 1.00”  
16”  
2. Hold bracket against wall with top of plate at 56”. Mark where  
mounting holes fall. Mount wall bracket. For wall mounting, the  
bolt centers on the brackets are at 16”to accomodate most wall  
stud spacing. See Fig. 1 & 2. Use a Level to ensure straightness.  
12 Ga.  
3. Attach bracket to wall with lag screws, concrete anchors, or  
other suitable hardware. See Fig. 2 & 3. Note: When installing  
the brackets on a concrete wall, mount 2 x 4’s between wall and  
brackets to stabilize and dampen vibration.  
Level  
2
4. Position Angle Ring around top of cone over bracket. Line up  
one hole in Ring with hole in each bracket at desired rotation of  
outlet. If rotation you desire does not correspond to an existing  
hole in Angle Ring, drill new ones. Use three 3/8” bolts (included)  
with washers & lock washers to secure the fan. See Fig. 4.  
5. Attach tightly with bolts. See Fig. 4.  
3
56” to top of plate.  
4
Distance tor minimum  
mounting height.  
Note: Please do not install an Oneida Dust Collection System alone. Competent  
assistance is advisable. Units are heavy!  
8
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before attaching filter, you must first  
carefully pull foam silencer on to end of  
plenum, pushing black plastic end against  
flange plate. It is a tight fit.  
VIII. Filter Assembly  
External 39” Filter Assembly  
*Silencer Included.  
1. Attach cartridge with hardware provided making sure  
gasket is attached. See Fig. 1  
TM  
The  
GORILLA  
2. If Filter requires additional support. Use the plate at the  
top of the filter to support the filter assembly.  
Silencer  
Filter  
Note: If filter cartridge is located away from the cyclone  
and motor, additional square-to-round connectors and pipe  
can be purchased.  
Gasket  
Material  
Fig. 1  
Rod  
Brace  
Washer  
Wing Nut  
(4) 3/8” x 1” Bolts  
(8) Washers  
(4) Serrated Nuts  
Dust Bin  
Dust Pan  
Clips (3)  
For Filter cleaning instructions and  
Dust Pan clipping instructions, see pg. 11.  
Option -  
No Filter Assembly  
1. Exhaust air to exterior of building.  
Mount directly at the hole in exterior  
wall or use a square-to-round transition  
and ductwork to vent air to exterior.  
* Exhaust Diverter -  
Can be used either  
up or down  
TM  
The  
GORILLA  
* Only usable on No Filter.  
Note: Do not return exhaust air to the shop unless filter media is added.  
Caution:  
If exhaust air is vented outside you must provide make up / return air.  
Flue gases (carbon monoxide) can be drawn into the shop from furnaces,  
water heaters or other appliances.  
Caution: Rotating blades! Keep hands clear. Keep  
people away from exhaust.  
9
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IX. Filter Maintenance  
External Filter Cartridge Cleaning Intervals  
When unit is turned off, use compressed air to blow dust off from  
exterior of filter. Hold nozzle at least 8” away from filter pleats*.  
Do not remove bottom dust pan before or during the blow-off  
process! Let dust settle into dust pan. Unclip and dump out dust.  
Filter removal is not required.  
* WARNING: A close, direct blast with the compressed air nozzle  
too close to filter, may damage filter media. Always wear safety  
glasses while blowing off filter.  
Caution: Fine dust collected in filter is hazardous  
to your health! Do not breathe!  
Fan / Blower & Cyclone Outside Placement  
Shown with  
optional  
Angle Iron  
Stand.  
Fan / Blower has a TEFC - Totally Enclosed Fan Cooled motor.  
Note: Use steel drum when placed outside.  
Before Operation:  
Mount system and connect cyclone and dust bin. Make sure dust bin is in place before turning on the dust  
collector.  
Do not operate Fan / Blower unless Cyclone and Dust Bin are in place! Motor will overheat!  
Electrical Wiring:  
Make sure power source matches wire voltage configurations on motor.  
Prior to connecting to the power line, check motor plate for proper voltage and rotation connection. Wire for  
counter-clockwise rotation. Fan wheel must rotate counter-clockwise if looking down on fan housing.  
Note: If fan is wired incorrectly and fan is rotating backwards, poor suction and airflow will result. See Wire  
Diagrams on motor plate.  
Use 12 gauge cord for the fan / blowers.  
Lubrication:  
See page 18 for instructions.  
Caution: Rotating Fan Blades! Keep objects clear of outlet.  
10  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X. Directions for Cleaning External Filter  
All steps should be done with a dust mask and eye protection.  
The External Filter can be cleaned using the following methods:  
1. Compressed air from outside.  
Blast air along pleats of the filter at about a 20 angle.  
Blast air out and away from you or anyone in the general  
area.  
Keep air nozzle at least 6” from filter. Closer blasts may  
damage filter material.  
6”  
2. Empty Dust Bin.  
Wait a few minutes for internal dust to settle then unclip  
and carefully empty dust bin.  
3. Rinse with water. (Optional)  
Keep nozzle at least 6” from filter and keep your pressure  
down. Closer blasts may damage filter material. Rinse  
off INSIDE of filter. Let filter dry completely before reuse  
or keep a spare filter on hand.  
Clipping Filter Dust Pan  
Position bottom of “U” on top of clip between filter pleats,  
then push bottom of clip underneath the rim of the dust  
pan. Space the three clips equally around the dust pan,  
making sure the pan is even with filter bottom and tightly  
sealed.  
Bottom of “U”  
Side view  
of clip  
11  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XI. Wiring Diagram for Magnetic Starter (220v, 1 ** )*  
Always use a licensed, professional electrician.  
Dedicated Receptacle Fed  
from 2 Pole Dedicated Circuit  
Breaker,  
6-20R  
6-20P  
Magnetic Starter -  
Mount Close to Collector  
I
O
Motor  
Baldor 2hp  
Catalog  
#VL3515T  
6’ Long Type SJT  
14 AWG Power Cord  
* Note: Motor Starter supplied  
with system is for 220v only.  
Note: This Dust Collector is  
pre-wired at the factory and  
need only be plugged into a  
NEMA 6020R dedicated  
electrical receptacle. 3hp  
single phase only.  
Open access cover on the  
Overload.  
Set the overload amperage  
dial for the SFA* amperage  
of your motor. The SFA*  
value can be found below:  
SFA = 12.1  
Note: Overload must be set  
or nuisance tripping may  
occur.  
(FLA 11.5)  
Optional Remote Controller diagram pg. 19  
*SFA - Service Factor Amperage  
*FLA - Full Load Amperage  
*Starter will not operate at any other voltages.  
**Starter is shown configured for 1O but can also be used for 2hp, 3O motors.  
12  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XII. Troubleshooting  
Unplug unit before servicing or cleaning.  
13  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Read Before Installing and Operating  
XIII. Fire Hazards -  
Oneida Collectors are designed for WOOD DUST only!!  
Wood shaping and cutting processes generate wood chips, shavings, and dust. These materials are considered  
combustible. Air borne wood dust below 420 microns in size (.017 of an inch) in certain concentration ranges when  
ignited can deflagrate (burn quickly).  
An ignition source such as a spark, or ember, can ignite a dust mixture resulting in an expanding flame front, which  
can cause an explosion if tightly contained. A disturbance that raises a cloud of accumulated fine dust can raise additional  
dust clouds, which can cause a series of explosions that can level an entire building. Until this type of fire has been  
witnessed, it is difficult to believe the devastation. This type of fire is rare but worth safeguarding against.  
The best way to avoid a wood shop fire is to keep the shop clean. A shop ankle deep in dust with layers of fine dust  
everywhere is an accident waiting to happen. A good dust collection system reduces overall fire hazards but also adds  
new concerns. A fire hazard is still present. Combustible material is now in the dust collector and storage container.  
The following points are worth heeding:  
It is the buyer’s responsibility to follow all applicable federal, state, local, OSHA, NFPA, or authorities having  
jurisdiction codes and regulations when installing and operating this dust collector.  
Fire Marshalls may want the unit located outside of the building. If the collector is located inside the facility,  
controls such as spark detection, suppression, or explosion venting may be required.  
Most local jurisdictions consult or adopt NFPA ( National Fire Protection Agency) codes. However, other codes  
may apply. Local codes may vary from jurisdiction to jurisdiction.  
NFPA 664 Code book, “Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking  
Facilities”, applies to woodworking operations that occupy areas of more than 5,000 sq. ft. or to areas where  
dust producing equipment requires an aggregate dust collection flow rate of more than 1500 cfm (Cubic Feet  
per Minute). This exempts some small operators from the NFPA code 664, but other codes may apply in your  
jurisdiction. Consult your local Fire Marshall for help. Additional information can be found in NFPA Code Book  
664.  
The customer assumes the responsibility for contacting their insurance underwriter with regard to specific  
application requirements of explosion venting or if additional fire protection and safety equipment may be  
required.  
Do not use this product to collect other types of dust or flammable vapors.  
Fire or explosion may occur!  
Never collect sparks from a bench grinder into a wood dust collector.  
Never introduce sparks or sources of ignition into the dust collector.  
Personnel should keep at least 20 feet away from unit.  
Check dust bin frequently and before leaving the shop for smoldering material.  
Keep portable Fire Extinguishers handy.  
The ABC type (dry chemical) is generally a good choice for small wood shops.  
Additional information on portable extinguishers can be found in NFPA 10 (Standard for Portable Fire Extinguishers).  
Be especially careful with sanding units. They can produce concentrations of dust in the combustible range. Make  
certain enough air volume is at the suction point to capture all the particulate generated.  
This high air volume will dilute the mixture below the lower limit of flammability. Be careful not to generate sparks into  
the sanding dust.  
Empty dust bin and clean filter often, especially when sanding.  
Don’t overload woodworking equipment, especially sanders. Excessive frictional heat can spontaneously ignite dust.  
Sparks can be generated in several ways:  
High-speed sanders and abrasive planers may strike foreign material  
Saws and edgers may strike foreign material and create a red hot metal fragment.  
Knots in hardwood can create frictional sparks.  
Tramp metal when drawn into the collector can spark against ductwork.  
Check wood stock for old nails and screws which can create red hot metal fragments.  
Avoid using excessively large wood waste storage bins.  
Always check storage bins for smoldering material before leaving for the day.  
Electrically ground all equipment and ducting. Static sparks can ignite wood dust. (Avoid using PVC drainpipe)  
Don’t allow accumulation of layers of fine dust on horizontal surfaces. (Especially overhead lights, electrical boxes,  
and fuse panels which can ignite dust)  
Unplug unit before servicing or cleaning.  
14  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XIV. Terms and Conditions  
Checking in Order  
Please look over the shipped order very carefully in the presence of the delivery person for damage or  
incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping  
packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive concealed  
damage. The shipping company will not take responsibility if the damage is not noted on the delivery receipt.  
In the event of shipping damage, call O.A.S. immediately so we can expedite replacements. Please check  
in all parts within 3 days from receiving order. Notify O.A.S. immediately of any missing or incorrect parts.  
O.A.S. does not accept any claims for damage or shortage after 3 days from date of delivery.  
Limited Warranty  
Oneida Air Systems warrants products it manufactures for a period of 2 years to the original purchaser from  
the date of purchase. Items not manufactured by O.A.S. are limited to their own manufacturer’s warranties.  
This warranty does not apply to defects due directly or indirectly to misuse, negligence, accidents, abuse,  
repairs, or alterations or lack of maintenance. This is Oneida Air Systems sole written warranty and any and  
all warranties that may be implied by law, including any merchantability or fitness, for any particular purpose,  
are hereby limited to the duration of this written warranty. O.A.S. does not warrant or represent that the  
merchandise complies with the provisions of any law or acts unless the manufacturer so warrants. In no  
event shall O.A.S.’s liability under this warranty exceed the purchase price paid for the product and any legal  
actions brought against Oneida Air Systems shall be tried in the State of New York, County of Onondaga.  
Oneida Air Systems shall in no event be liable for death, injuries to persons or property or for incidental,  
contingent, special, or consequential damages arising from the use of our product.  
Oneida Air Systems does not warrant or authorize use of wood dust collectors for other purposes. This  
includes wood products that are treated, coated, or otherwise altered from their natural state.  
*Note: Motors should be protected from extreme weather to prolong motor life.  
Single phase motors should only be started and stopped up to 4 - 10 times per  
hour. Starting single phase motors more frequently can cause heat build up  
and can cause the motor overload to trip or cause motor damage. In general,  
motors should be started and stopped as little as possible for maximum  
lifespan and best economy (electrical use).  
Delivery Risk of Loss  
Products will be shipped to Buyer’s single destination. Title and risk of loss shall pass to the Buyer upon  
delivery to such destination. Buyer pays transportation expenses. Dates of shipment are advisory and O.A.S.  
will make reasonable efforts to ship on or before the date states for shipment, however, O.A.S. shall not incur  
any liability for failure to ship on that date.  
Returned Goods Policy  
Buyer must inform O.A.S. of any shortage or damage, by so noting in writing, on the freight delivery bill prior  
to signing to indicate receipt of shipment. All claims, including claims covered under the limited warranty, are  
subject to inspection and investigation by O.A.S.. O.A.S. reserves the right to inspect and investigate all  
returned products before Buyer’s claim is settled. All products returned for a refund must be unused, resaleable  
and purchased within the last six months. There are no refunds on flex hose, custom made components,  
or partial kit items. Kits must be returned in full (all components) for credit. There will be a 25% restocking  
fee applied to any returned items.  
Some parts of this system are outsourced and not made in the USA.  
15  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Included Hardware:  
XV. Stand Assembly  
(32) 5/16 x 1” Bolts - AFB155190  
(32) 5/16 Nuts - AFW180000  
(64) 5/16 Flat Washers - AFT155175  
21 3/4”  
23 7/8”  
LEFT  
21 3/4”  
23 7/8”  
RIGHT  
23 7/8”  
56”  
21 3/4”  
The two triangular  
slotted braces go on  
the left and right top.  
21 3/4”  
FRONT  
has no  
lower brace across.  
Lower left and right  
braces have no slots  
in top.  
Optional Angle Iron Stand  
Washers  
Optional 35 gal. Angle Iron Stand - STG021035  
Nut  
1.Uprights - SXX000056  
2. Braces - SXX000021  
Optional 55 gal. Angle Iron Stand - STG023055  
1. Uprights - SXX000068  
Bolt  
2. Braces - SXX000021  
Stand  
16  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25”  
25”  
XVI. Accessories  
Bolt Together  
Angle Iron Stand  
STG021035 - 35 gal. Stand  
STG021055 - 55 gal. Stand  
56”  
Kit Contents:  
Filter Efficiency Gauge  
FXK000000  
2
3
1
4
0
5
INCHES W.C.  
This easy to read gauge takes the guesswork out of knowing when your filters need  
to be cleaned and tells you how much pressure is backed up behind your filters. It  
reads pressure from plenum to gauge up to 8’ away and allows you to keep your dust  
collection system running efficiently.  
Gauge  
Bracket  
8 Ft. Hose and Connection  
Replacement  
Filter  
FCS133900  
13” x 39” / 95 Sq. Ft. Spun-Bonded. Filters 99.9% of test material from 0.2 to 2 microns.  
Dust Containers  
35 gal. Fiber  
55 gal. Fiber  
55 gal. Steel  
The BAG Gripper  
ABX000000  
The BAG Gripper provides the ability to use convenient plastic bags inside  
your dust drum. It provides a constant, negative pressure on the outside  
surface of the plastic bag that keeps it pulled tight against the sides of the  
dust drum. Can be used with 35 and 55 gal. barrels. Must be wired into  
your system.  
17  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XVII. Fan Motor Maintenance  
Per Baldor specifications, their 2 pole motors (3600 RPM) motors are to be relubricated every 5500 hours.  
Table 1 - Service Conditions  
Table 2 - Lubrication Interval Multiplier  
Per Baldor specifications, add .30 ounces (8.4 grams) of Mobil Polyrex grease by weight or .6 cubic inches (2 teaspoons)  
of Mobil Polyrex grease by volume.  
18  
c
2HP Super Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XVIII. Remote Wiring Diagram  
Retrofit (Wiring) of Wireless Remote into 220V Control Circuit of Square D / Telemecanique Mag Starters  
Square D  
‘1A’  
Telemecanique  
‘3’  
‘2’  
Mag Starters  
BRN  
Wire  
Nuts  
AMK Series  
Plug into 9 pin female Molex  
on back panel of starter base.  
YEL  
YEL  
3 Wire  
Adaptor  
Molex  
YEL  
Important! Remove this factory  
installed Jumper Wire.  
AMA000000  
RED  
RED  
Female molex  
at bottom of  
starter  
A1  
A2  
3
4
1
2
13NO  
1L1 3L2 5L3  
Start / Stop  
BRN  
Push Button  
Assembly on  
Starter (Molex)  
BRN  
YEL  
Contactor  
RED  
RED  
Start  
Stop  
6T3  
2T1 4T2  
Amp  
YEL  
BRN  
BRN  
Adjustment  
Dial  
Remote  
‘Black Box’  
Overload  
YEL  
RED  
RED  
98  
97 95  
96  
AMR220000  
BRN  
Retrofit (Wiring) of Wireless Remote into 220V OAS Import Magnetic Starters: AMI020000  
AMI030000  
YEL  
BRN  
NHD, Inc.  
Mag Starters  
BRN  
YEL  
RED  
Remote is mounted inside  
A1  
A2  
starter top cover by using  
double-sided tape  
(supplied).  
13NO  
1L1 3L2 5L3  
RED  
YEL  
BRN  
BRN  
Contactor  
Remote  
‘Black Box’  
6T3 14NO  
2T1 4T2  
YEL  
RED  
RED  
Red  
Overload  
Amp  
Adjustment  
Dial  
Remote Controller Diagram  
Red  
Red  
Red:  
AC Power  
Blue Red  
98  
97 96  
95  
BRN  
Yellow  
Yellow  
(ON) (OFF)  
Yellow:  
N/O contact (ON)  
2T1 4T2 6T3  
Black  
(antenna)  
Remove this  
factory installed  
red wire!  
Brown  
Brown  
Brown:  
N/C contact (OFF)  
19  
c
2HP Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional - XIX. Filter Efficiency Gauge Mounting Instructions  
Rectangular Plenum  
2
3
1
4
Can be  
attached  
up to 8’  
away.  
0
5
INCHES W.C.  
OR  
Mounting Instructions  
1. Mount brass static pressure tube in plenum with tip pointed into the air stream.  
Use mounting bracket and sheet metal screws if interior of plenum is not  
accessible. Refer to drawings for location of brass static pressure tube.  
2. Refer to instructions provided with gauge for mounting to bracket.  
3. Mount gauge up to 8’ away, mounting it closer will not affect reading.  
4. Connect clear tubing from brass static pressure tube to the port labeled  
Elbow Plenum  
“high” on the back of the pressure gauge.  
(Side View)  
5. Make sure the tubing is not crushed or kinked along its entire length, cut  
shorter if necessary.  
Air Flow  
to Filter  
Gauge Reading Instructions  
1. Gauge may need to be zeroed. Follow the instructions provided with  
pressure gauge.  
2. Take the initial reading with cleaned filter(s) and the typical number of blast  
gates open in normal operation.  
3. Always read the gauge with the same number of gates open. The more  
gates open, the higher the pressure reading on the gauge.  
4. When the gauge rises to 3”, it’s time to clean your filter(s).  
After many cleaning cycles, a filter’s pressure will rise after each cleaning. An older filter does  
not get as clean as a new filter.  
20  
c
2HP Dust Gorilla Owner’s Manual  
O.A.S. 2007  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Coffeemaker 7995311 User Manual
Miele Dishwasher G 2670 SC User Manual
Miele Refrigerator KF 1801 SF User Manual
Multiquip Portable Generator DCA 10SPX4 User Manual
NordicTrack Home Gym NTMC29931 User Manual
Olympus Camcorder 227665 User Manual
Oster Blender BLSTET B User Manual
Panasonic Air Conditioner CW XC125HU User Manual
Parker Hannifin Stereo Amplifier EC106 User Manual
Pasquini Espresso Company Coffee Grinder 6 S A User Manual