INSTRUCTION MANUAL
7 series
Automatic Wrist Blood
Pressure Monitor
Model BP652
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Thank you for purchasing the OMRON® BP652 IntelliSense® Automatic Wrist Blood
Pressure Monitor.
Fill in for future reference.
DATE PURCHASED:__________________
SERIAL NUIMBER:___________________
s 3TAPLE YOUR PURCHASE RECEIPT HERE
s 2EGISTER YOUR PRODUCT ONꢀLINE AT
WWWꢁREGISTERꢀOMRONꢁCOM
The monitor is compact and easy-to-use at home, at work, and during travel. Perfect for
people who frequently monitor their own blood pressure.
Your new digital blood pressure monitor uses the oscillometric method of blood pres-
sure measurement. This means the monitor detects your blood’s movement through
your brachial artery and converts the movements into a digital reading. An oscillomet-
ric monitor does not need a stethoscope so the monitor is simple to use.
Clinical research has proven a direct relationship between blood pressure in the wrist
DQGꢀEORRGꢀSUHVVXUHꢀLQꢀWKHꢀDUPꢁꢀ&KDQJHVꢀLQꢀZULVWꢀEORRGꢀSUHVVXUHꢀUHÀHFWꢀFKDQJHVꢀLQꢀDUPꢀ
blood pressure because the arteries in the wrist and the arm are close to each other.
Frequently measuring the blood pressure in your wrist will provide your physician with
an accurate indication of changes in your blood pressure.
The BP652 comes with the following components:
ꢀ0RQLWRUꢀꢀ6WRUDJHꢀ&DVHꢀꢀꢂꢀ³$$$´ꢀ$ONDOLQHꢀ%DWWHULHV
ꢀ,QVWUXFWLRQꢀ0DQXDOꢀSULQWHGꢀLQꢀ(QJOLVKꢀDQGꢀ6SDQLVKꢀꢀ4XLFNꢀ6WDUWꢀ*XLGH
The BP652 IntelliSense® Automatic Wrist Blood Pressure Monitor is intended for home use.
SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com3. All Manuals Search And Download.
SAFETY INFORMATION
To assure the correct use of the product, basic safety measures should always be
followed including the warnings and cautions listed in this instruction manual.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury to the user or patient or
damage to the equipment or other property.
CAUTION
OPERATING THE DEVICE
ꢀ&RQWDFWꢀ\RXUꢀSK\VLFLDQꢀIRUꢀVSHFL¿FꢀLQIRUPDWLRQꢀDERXWꢀ\RXUꢀEORRGꢀSUHVVXUHꢁꢀ
Self-diagnosis and treatment using measured results may be dangerous. Follow the
instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on measurement results from this blood pressure
monitor. Take medication as prescribed by your physician. Only a physician is
TXDOL¿HGꢀWRꢀGLDJQRVHꢀDQGꢀWUHDWꢀ+LJKꢀ%ORRGꢀ3UHVVXUHꢁ
The monitor is not intended to be a diagnostic device.
ꢀ,IꢀEDWWHU\ꢀÀXLGꢀVKRXOGꢀJHWꢀLQꢀ\RXUꢀH\HVꢃꢀLPPHGLDWHO\ꢀULQVHꢀZLWKꢀSOHQW\ꢀRIꢀFOHDQꢀ
water. Contact a physician immediately.
If you have a condition that may compromise circulation, you may get an inaccurate
reading with this device. Consult your physician before using this device.
Read all of the information in the instruction manual and any other literature in the
box before operating the unit.
This device is intended for use in measuring blood pressure and pulse rate in the
adult population. Do not use this device on infants or persons who cannot express
their intentions.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable
local regulations. Unlawful disposal may cause environmental pollution.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
SAFETY INFORMATION
Do not use a cellular phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not
approved for use with the device may damage the unit.
ꢀ8VHꢀRQO\ꢀꢄꢁꢅꢀ9ꢀ³$$$´ꢀDONDOLQHꢀEDWWHULHVꢀZLWKꢀWKLVꢀGHYLFHꢁꢀ'RꢀQRWꢀXVHꢀRWKHUꢀW\SHVꢀRIꢀ
batteries. This may damage the unit.
CARE AND MAINTENANCE
ꢀ'RꢀQRWꢀVXEMHFWꢀWKHꢀPRQLWRUꢀWRꢀVWURQJꢀVKRFNVꢃꢀVXFKꢀDVꢀGURSSLQJꢀWKHꢀXQLWꢀRQꢀWKHꢀÀRRUꢁ
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
ꢀ&KDQJHVꢀRUꢀPRGL¿FDWLRQꢀQRWꢀDSSURYHGꢀE\ꢀWKHꢀPDQXIDFWXUHUꢀZLOOꢀYRLGꢀWKHꢀXVHUꢀ
warranty. Do not disassemble or attempt to repair the unit or components.
Download from Www.Somanuals.com5. All Manuals Search And Download.
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes
before taking a measurement. Rest for at least 15 minutes before taking the
measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. The cuff can be applied to your left or right wrist.
4. Measurements should be taken in a quiet place.
5. Position the unit at heart level throughout the measurement.
6. Remain still and do not talk during the measurement.
7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return
to the condition prior to taking the blood pressure measurement. You may need to
increase the wait time depending on your individual physiological characteristics.
8. Keep a record of your blood pressure and pulse readings for your physician. A
single measurement does not provide an accurate indication of your true blood
pressure. You need to take and record several readings over a period of time. Try to
measure your blood pressure at the same time each day for consistency.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
KNOW YOUR UNIT
Main Unit:
Display
Wrist cuff
Memory (MEM)
button
START/STOP button
Date/Time setting
) button
User ID selection
switch
(
SET button
Date/Time setting
) button
(
Battery compartment
Components:
INSTRUCTION MANUAL
7
series
Automatic Wrist Blood
Pressure Monitor
Model BP652
5329415-9A
INTRODUCTION
®
®
Thank you for purchasing the OMRON BP652 IntelliSense Automatic Wrist Blood
Pressure Monitor
.
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
s
3TAPLE YouPURHASe rEEIPT HERE
2 “AAA” Alkaline Batteries
Instruction
Manual
Quick Start
Guide
Download from Www.Somanuals.com7. All Manuals Search And Download.
UNIT DISPLAY
Positioning indicator
Diastolic blood pressure
Memory symbol
(Displayed when viewing
values stored in memory)
Systolic blood pressure
Deflation symbol
Average value symbol
(Refer to“Using the
Memory Function”.)
Irregular heartbeat symbol
Movement error symbol
(Displayed if you move
your body during the
measurement)
Blood pressure level
indicator
Buzzer symbol
User ID symbol (A or B)
(If ³GUEST´ is selected, A
or B will not be displayed.)
Date/Time display
Heartbeat symbol
(Flashes during
measurement)
Wrist symbol
Battery low symbol
Pulse display
Download from Www.Somanuals.com. All Manuals Search And Download.
8
DISPLAY SYMBOLS
IRREGULAR HEARTBEAT SYMBOL (
)
When the monitor detects an irregular rhythm two or more times during the
measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the
measurement values.
$QꢀLUUHJXODUꢀKHDUWEHDWꢀUK\WKPꢀLVꢀGH¿QHGꢀDVꢀDꢀ
rhythm that varies by less than 25% from the
average rhythm or 25% more than the average
rhythm detected while the monitor is measuring
the systolic and diastolic blood pressure.
.ORMAL (EARTBEAT
Pulse
Blood
pressure
If the irregular heartbeat symbol (
)
)RREGULAR (EARTBEAT
displays with your measurement results,
we recommend you consult your
physician. Follow the directions of your
doctor.
Short Long
Pulse
Blood
pressure
MOVEMENT ERROR SYMBOL (
)
The Movement Error Symbol ( ) is displayed if you move your body during the
measurement. Please remove the wrist cuff, and wait 2-3 minutes. Reapply the wrist
cuff and take another measurement.
Internationally recognized guidelines for upper limit of
normal home blood pressure readings are as follows:
Home Guideline for Upper Limit of Normal BP
Systolic Blood Pressure
Diastolic Blood Pressure
135 mmHg
85 mmHg
Download from Www.Somanuals.com9. All Manuals Search And Download.
DISPLAY SYMBOLS
This is a general guideline because blood pressure depends on age and morbidity.
A lower home blood pressure goal may be recommended for certain patients,
including diabetic patients, pregnant women, and patients with renal failure.
WARNING
&RQWDFWꢀ\RXUꢀSK\VLFLDQꢀIRUꢀVSHFL¿FꢀLQIRUPDWLRQꢀDERXWꢀ\RXUꢀEORRGꢀSUHVVXUHꢁꢀ
Self-diagnosis and treatment using measured results may be dangerous.
Follow the instructions of your physician or licensed healthcare provider.
WARNING
DO NOT adjust medication based on measurement results from this blood
pressure monitor. Take medication as prescribed by your physician. Only
DꢀSK\VLFLDQꢀLVꢀTXDOL¿HGꢀWRꢀGLDJQRVHꢀDQGꢀWUHDWꢀ+LJKꢀ%ORRGꢀ3UHVVXUHꢁ
WARNING
The monitor is not intended to be a diagnostic device.
Download from Www.Somanuals.com. All Manuals Search And Download.
10
BATTERY INSTALLATION
CAUTION
8VHꢀRQO\ꢀꢄꢁꢅ9ꢀ³$$$´ꢀDONDOLQHꢀEDWWHULHVꢀZLWKꢀWKLVꢀGHYLFHꢁ
1. Press the hook on the bottom of the battery cover
and lift the cover off in the direction of the arrow.
ꢂꢁꢀ ,QVWDOOꢀꢂꢀ³$$$´ꢀVL]HꢀEDWWHULHVꢀVRꢀWKHꢀꢆꢀꢇSRVLWLYHꢈꢀDQGꢀꢉꢀ
(negative) polarities match the polarities of the battery
compartment as indicated.
3. Set the date and time.
ꢀ
5HIHUꢀWRꢀ³6HWWLQJꢀWKHꢀ'DWHꢀDQGꢀ7LPH´ꢁ
4. Replace the battery cover.
NOTE: Make sure that the battery cover is securely in
position.
Download from Www.Somanuals.co1m1. All Manuals Search And Download.
BATTERY INSTALLATION
BATTERY REPLACEMENT
Low Battery Indicator
When the Low Battery Indicator appears on the display, turn the monitor off and
remove all the batteries. Replace with 2 new batteries at the same time. Long-life
alkaline batteries are recommended.
WARNING
,IꢀEDWWHU\ꢀÀXLGꢀVKRXOGꢀJHWꢀLQꢀ\RXUꢀH\HVꢃꢀLPPHGLDWHO\ꢀULQVHꢀZLWK
plenty of clean water. Contact a physician immediately.
NOTES:ꢀ ꢀ7XUQꢀWKHꢀXQLWꢀRIIꢀEHIRUHꢀUHSODFLQJꢀWKHꢀEDWWHULHVꢁꢀ,IꢀWKHꢀEDWWHULHVꢀDUHꢀUHPRYHGꢀ
while the unit is still on, the date and time will be reset to that of the
previous use. The measurement results are not deleted.
ꢀ:KHQꢀWKHꢀEDWWHULHVꢀDUHꢀUHSODFHGꢃꢀ\RXꢀPD\ꢀQHHGꢀWRꢀUHVHWꢀWKHꢀGDWHꢀDQGꢀWLPHꢁꢀ,Iꢀ
WKHꢀ\HDUꢀLVꢀÀDVKLQJꢀRQꢀWKHꢀGLVSOD\ꢃꢀUHIHUꢀWRꢀ³6HWWLQJꢀWKHꢀ'DWHꢀDQGꢀ7LPH´ꢁ
ꢀ7KHꢀEDWWHULHVꢀLQFOXGHGꢀZLWKꢀWKHꢀGHYLFHꢀPD\ꢀKDYHꢀDꢀVKRUWHUꢀOLIHꢁ
CAUTION
Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawful disposal may cause environmental
pollution.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
SETTING THE DATE AND TIME
6HWꢀWKHꢀPRQLWRUꢀWRꢀWKHꢀFXUUHQWꢀGDWHꢀDQGꢀWLPHꢀEHIRUHꢀWDNLQJꢀDꢀPHDVXUHPHQWꢀIRUꢀWKHꢀ¿UVWꢀ
time.
1. TO START THE SETTING
Press the Date/Time Setting button ( ) to adjust the date
and time.
7KHꢀ\HDUꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ
2. SETTING THE YEAR
Press the Date/Time Setting button ( ) to advance by
increments of one year.
Press the Date/Time Setting button ( ) to set the current
year.
7KHꢀPRQWKꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ
NOTES:ꢀ ꢀ7KHꢀ\HDUꢀFDQꢀEHꢀVHWꢀEHWZHHQꢀꢂꢊꢊꢋꢀDQGꢀ
2030. When the display reaches 2030, it
will return to 2009.
ꢀ3UHVVꢀDQGꢀKROGꢀWKHꢀꢇꢀ ) button to
increase the date and time values faster.
3. SETTING THE MONTH
Press the Date/Time Setting button ( ) to advance by
increments of one month.
Press the Date/Time Setting button ( ) to set the current
month.
7KHꢀGD\ꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ
Download from Www.Somanuals.co1m3. All Manuals Search And Download.
SETTING THE DATE AND TIME
4. SETTING THE DAY
Press the Date/Time Setting button ( ) to advance by
increments of one day.
Press the Date/Time Setting button ( ) to set the current
day.
7KHꢀKRXUꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ
5. SETTING THE HOUR
The time is set using AM or PM.
Press the Date/Time Setting button ( ) to advance by
increments of one hour.
Press the Date/Time Setting button ( ) to set the current
hour.
7KHꢀPLQXWHꢀÀDVKHVꢀRQꢀWKHꢀGLVSOD\ꢁ
6. SETTING THE MINUTE
Press the Up button ( ) to advance by increments of one
minute.
Press the Date/Time Setting button ( ) to set the minute
setting.
7. TO TURN THE MONITOR OFF
Press the START/STOP button.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
SETTING THE ADVANCED POSITIONING SENSOR (APS)
You can change the options for various settings on your monitor. Pressing the SET
button to change a setting. Press the MEM button to select the options for that setting.
$IWHUꢀVHOHFWLQJꢀDꢀVHWWLQJꢃꢀSUHVVꢀWKHꢀ67$57ꢌ6723ꢀEXWWRQꢀWRꢀFRQ¿UPꢀWKHꢀVHWWLQJꢀDQGꢀWXUQꢀ
the power off.
SETTING THE POSITIONING INDICATOR
1. Select your User ID.
2. Press the SET button.
NOTE:ꢀ7KHꢀGHIDXOWꢀVHWWLQJꢀLVꢀ³RQꢄ´ꢁ
User A
User B
ꢍꢁꢀ 3UHVVꢀWKHꢀ0(0ꢀEXWWRQꢀWRꢀVHOHFWꢀWKHꢀ3RVLWLRQLQJꢀLQGLFDWRUꢀ³RQꢄ´ꢃ³RQꢂ´ꢃꢀRUꢀ³R))´ꢁ
on1: After the Positioning indicator lights in blue for more than 2 seconds, or
in orange for more than 5 seconds, measurement starts automatically, even
though the monitor is not in the proper position.
on2: The Positioning indicator lights in blue for more than 2 seconds, measurement
starts automatically.
Measurement will not start if it lights in orange.
oFF: Measurement starts without the Positioning indicator.
Download from Www.Somanuals.co1m5. All Manuals Search And Download.
SETTING THE ADVANCED POSITIONING SENSOR (APS)
SETTING FOR RIGHT OR LEFT WRIST MEASUREMENT
1. While in the setting mode, press the SET button until
the wrist symbol ( or ) appears on the display.
127(6ꢎꢀ ꢀ7KHꢀGHIDXOWꢀVHWWLQJꢀLVꢀ³ ´ꢁ
ꢀ$IWHUꢀ\RXꢀFKRRVHꢀ³R))´ꢀIRUꢀWKHꢀ
Positioning indicator, the monitor skips
this process.
2. Press the MEM button to select the left wrist ( ) or the right wrist ( ).
SETTING THE BUZZER
1. While in the setting mode, press the SET button until
the buzzer symbol ( ) appears on the display.
NOTE:ꢀ7KHꢀGHIDXOWꢀVHWWLQJꢀLVꢀ³RQꢄ´ꢀRUꢀ³RQ´ꢃꢀ
depending on the Positioning indicator you
set.
2. Press the MEM button to select the buzzer setting.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
SETTING THE ADVANCED POSITIONING SENSOR (APS)
,IꢀWKHꢀ3RVLWLRQLQJꢀLQGLFDWRUꢀLVꢀ³RQꢄ´ꢀRUꢀ³RQꢂ´ꢎ
on1: The buzzer sounds only when the monitor is in proper position.
on2: The buzzer sounds a series of two short blips if your wrist is too far away from
the measuring position, and beeps when your wrist is in the proper position.
oFF: The buzzer will not sound.
,IꢀWKHꢀ3RVLWLRQLQJꢀLQGLFDWRUꢀLVꢀ³R))´ꢎ
on: The buzzer sounds when pressing any buttons.
oFF: The buzzer will not sound.
RESETTING TO THE DEFAULT SETTING
7KHꢀSRVLWLRQLQJꢀLQGLFDWRUꢀLVꢀVHWꢀ³RQꢄ´ꢃꢀWKHꢀZULVWꢀIRUꢀPHDVXUHPHQWꢀLVꢀVHWꢀ³ ´ꢃꢀDQGꢀWKHꢀ
EX]]HUꢀLVꢀVHWꢀ³RQꢄ´ꢀDVꢀGHIDXOWꢁ
To reset to the default setting, press and hold the SET button while in the setting mode,
then press the START/STOP button simultaneously for more than 2 seconds.
Download from Www.Somanuals.co1m7. All Manuals Search And Download.
APPLYING THE WRIST CUFF
CAUTION
Read all of the information in the instruction manual and any other
literature in the box before operating the unit.
CAUTION
This device is intended for use in measuring blood pressure and
pulse rate in the adult population. Do not use this device on infants
or persons who cannot express their intentions.
APPLYING THE CUFF ON THE LEFT WRIST
1. Roll up sleeve. Make sure your sleeve is not rolled up too
WLJKWO\ꢀRQꢀ\RXUꢀDUPꢁꢀ7KLVꢀPD\ꢀFRQVWULFWꢀWKHꢀÀRZꢀRIꢀEORRGꢀ
in your arm.
2. Wrap the cuff directly against your skin.
Do not apply over clothing. Place the cuff over your left
wrist with your left thumb facing upward.
3. Position the cuff leaving a clearance of approximately 1/2
to 1 inch between the cuff and the bottom of your palm.
4. Hold the bottom part of the cuff and wrap it around the
ZULVWꢀVRꢀLWꢀ¿WVꢀFRPIRUWDEO\ꢀDQGꢀVHFXUHO\ꢀDURXQGꢀ\RXUꢀZULVWꢁ
NOTE: Make sure the wrist cuff does not cover the
protruding part of the wrist bone on the outside of
the wrist.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
APPLYING THE WRIST CUFF
5. Fold the remaining part of the wrist cuff back out of the
way.
APPLYING THE CUFF ON THE RIGHT WRIST
When taking a measurement using the right wrist position the
cuff as shown in the illustration.
5HIHUꢀWRꢀ³6HWWLQJꢀIRUꢀ5LJKWꢀRUꢀ/HIWꢀ:ULVWꢀIRUꢀ0HDVXUHPHQW´ꢁ
Download from Www.Somanuals.co1m9. All Manuals Search And Download.
TAKING A MEASUREMENT
The monitor is designed to take measurements and store the measurement values in
memory for two people using USER ID A and USER ID B. The monitor can be used to
WDNHꢀDꢀVLQJOHꢀPHDVXUHPHQWꢀXVLQJꢀWKHꢀ*8(67ꢀPRGHꢀDUHꢀQRWꢀVWRUHGꢀLQꢀWKHꢀPHPRU\ꢁ
ꢄꢁꢀ 6LWꢀFRPIRUWDEO\ꢀLQꢀDꢀFKDLUꢀZLWKꢀ\RXUꢀIHHWꢀÀDWꢀRQꢀWKHꢀÀRRUꢁ
2. Select your User ID (A or B).
User A
User B
3. Hold your arm across your chest at heart level.
+ROGꢀ\RXUꢀHOERZꢀ¿UPO\ꢀWRꢀDYRLGꢀERG\ꢀPRYHPHQWꢁ
Sit still and do not talk or move during the measurement.
4. When arm is in correct position orange light will turn on.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
TAKING A MEASUREMENT
5. Press the START/STOP button.
All symbols appear on the display.
7KHꢀFXIIꢀVWDUWVꢀWRꢀLQÀDWHꢀDXWRPDWLFDOO\ꢁ
$VꢀWKHꢀFXIIꢀLQÀDWHVꢃꢀWKHꢀPRQLWRUꢀDXWRPDWLFDOO\ꢀGHWHUPLQHVꢀ\RXUꢀLGHDOꢀLQÀDWLRQꢀOHYHOꢁꢀ
7KLVꢀPRQLWRUꢀGHWHFWVꢀ\RXUꢀEORRGꢀSUHVVXUHꢀDQGꢀSXOVHꢀUDWHꢀGXULQJꢀLQÀDWLRQꢁ
The Heartbeat Symbol ( ꢈꢀÀDVKHVꢀDWꢀHYHU\ꢀKHDUWEHDWꢁ
Remain still and do not move until the entire measurement process is completed.
NOTE:ꢀ7RꢀVWRSꢀWKHꢀLQÀDWLRQꢀRUꢀPHDVXUHPHQWꢃꢀSXVKꢀWKHꢀ67$57ꢌ6723ꢀEXWWRQꢁꢀ7KHꢀ
PRQLWRUꢀZLOOꢀVWRSꢀLQÀDWLQJꢃꢀVWDUWꢀGHÀDWLQJꢃꢀDQGꢀZLOOꢀWXUQꢀRIIꢁ
5. After the monitor has detected your blood pressure
DQGꢀSXOVHꢀUDWHꢃꢀWKHꢀFXIIꢀDXWRPDWLFDOO\ꢀGHÀDWHVꢁꢀ<RXUꢀ
blood pressure and pulse rate are displayed.
6. Press the START/STOP button to turn the monitor off.
NOTE: The monitor will automatically turn off after two minutes.
Download from Www.Somanuals.co2m1. All Manuals Search And Download.
USING THE MEMORY FUNCTION
Every time you complete a measurement the monitor stores the blood pressure and
pulse rate for each user (A and B) in the memory. The monitor automatically stores up
to 100 sets of measurement values (blood pressure and pulse rate) for each user (A and
B). When 100 sets of measurement values are stored, the oldest record is deleted to
save the most recent values.
AVERAGING FUNCTION
The monitor calculates the average reading based on up to the three most recent sets of
measurement values taken within 10 minutes of the most recent reading.
NOTE: If two sets of measurement values are stored in the memory for the 10 minute
period, the average is based on the two sets of measurement values. If only
one set of measurement values is stored, this is displayed as the average.
TO DISPLAY THE MEASUREMENT VALUES
1. Press the MEM button to display the average reading based on the three most recent
sets of measurement values taken within 10 minutes of the most recent reading.
The Average Value Symbol ( ) appears on the display when the average reading is
shown.
2. Press the MEM button to display the set of measurement values from the most
recent to the oldest.
Alternating date/time
display
Download from Www.Somanuals.com. All Manuals Search And Download.
22
USING THE MEMORY FUNCTION
NOTES:ꢀꢀꢀ7KHꢀGDWHꢀDQGꢀWLPHꢀDUHꢀDOWHUQDWHO\ꢀGLVSOD\HGꢀZLWKꢀWKHꢀPHDVXUHPHQWꢀ
values.
ꢀ3UHVVꢀWKHꢀ0(0ꢀEXWWRQꢀUHSHDWHGO\ꢀWRꢀGLVSOD\ꢀWKHꢀQH[WꢀYDOXHVꢁ
ꢀ3UHVVꢀDQGꢀKROGꢀWKHꢀ0(0ꢀEXWWRQꢀWRꢀGLVSOD\ꢀWKHꢀYDOXHVꢀIDVWHUꢁ
3. Press the START/STOP button to turn the monitor off.
TO DELETE ALL VALUES STORED IN THE MEMORY
The values stored in the memory are deleted by User ID. You cannot partially delete
values stored in the memory. All values for the user you select will be deleted.
1. Select your User ID (A or B).
2. Press the MEM button to turn the monitor on.
3. While holding the MEM button, press the START/STOP button down for more than
5 seconds until the display appears as it does in the following illustration.
4. Press the START/STOP button to turn the monitor off.
NOTE: The monitor will automatically turn off after two minutes.
Download from Www.Somanuals.co2m3. All Manuals Search And Download.
CARE AND MAINTENANCE
To keep your digital blood pressure monitor in the best condition and protect the unit
from damage, follow the directions listed below:
Do not forcefully bend the cuff. Do not fold tightly.
Clean the monitor with a soft dry cloth.
Do not use any abrasive or volatile cleaners.
Do not attempt to clean the cuff.
CAUTION
Do not submerge the device or any of the components in water. Do not subject
the monitor to extreme hot or cold temperatures, humidity or direct sunlight.
CAUTION
Store the device and the components in a clean, safe location.
CAUTION
Do not subject the monitor to strong shocks, such as dropping the unit on the
ÀRRUꢁ
Remove the batteries if the unit will not be used for three months or longer. Always
replace all the batteries with new ones at the same time.
Use the unit consistent with the instruction provided in this manual.
Use only authorized parts and accessories.
Use the unit in a manner consistent with the instructions provided in this manual.
CAUTION
Use only Omron authorized parts and accessories. Parts and accessories
not approved for use with the device may damage the unit.
CAUTION
&KDQJHVꢀRUꢀPRGL¿FDWLRQꢀQRWꢀDSSURYHGꢀE\ꢀWKHꢀPDQXIDFWXUHUꢀZLOOꢀYRLGꢀWKHꢀXVHUꢀ
warranty. Do not disassemble or attempt to repair the unit or components.
Download from Www.Somanuals.com. All Manuals Search And Download.
24
ERROR INDICATORS
SYMBOL
CAUSE
CORRECTION
Take another measurement and
remain still until the measurement is
complete.
Monitor could not
detect pulse wave.
&XIIꢀXQGHUꢉLQÀDWHGꢁ
Cuff not applied
correctly.
Remove the monitor from your
wrist.
5HDGꢀ³7DNLQJꢀDꢀ0HDVXUHPHQW´ꢁ
Wait 2-3 minutes.
Take another measurement.
&XIIꢀRYHUꢉLQÀDWHGꢁ
Device error.
Contact Customer Service.
Movement during
measurement.
Keep still and take another
measurement.
Remove the monitor from your
wrist. Wait 2-3 minutes and then
take another measurement. Repeat
WKHꢀVWHSVꢀLQꢀVHFWLRQꢀ³$SSO\LQJꢀ
WKHꢀ:ULVWꢀ&XIIꢁ´ꢀ,IꢀWKLVꢀV\PEROꢀ
continues to appear, contact your
doctor.
Irregular or weak
pulses are detected.
Replace the batteries.
5HIHUꢀWRꢀ³%DWWHU\ꢀ,QVWDOODWLRQ´ꢁ
Batteries are worn.
Download from Www.Somanuals.co2m5. All Manuals Search And Download.
TROUBLESHOOTING TIPS
PROBLEM
CAUSES AND SOLUTIONS
Replace both batteries with new ones at the same
time. Check the battery installation for proper
placement of the battery polarities.
No power.
No display appears on the unit.
Blood pressure varies constantly. Many factors
including stress, time of day, how you wrap the
cuff, may affect your blood pressure.
Measurement values appear too
high or too low.
5HYLHZꢀWKHꢀVHFWLRQVꢀ³%HIRUHꢀ7DNLQJꢀDꢀ
0HDVXUHPHQW´ꢀDQGꢀ³7DNLQJꢀDꢀ0HDVXUHPHQW´ꢁ
Download from Www.Somanuals.com. All Manuals Search And Download.
26
FCC STATEMENT
Note:
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)
This product has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference
in a residential installation. The product generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If the product does
cause harmful interference to radio or television reception, which can be determined by
turning the product on and off, the user is encouraged to try to correct the interference
by one or more of the following measures:
ꢀ5HRULHQWꢀRUꢀUHORFDWHꢀWKHꢀUHFHLYLQJꢀDQWHQQDꢁ
ꢀ,QFUHDVHꢀWKHꢀVHSDUDWLRQꢀEHWZHHQꢀWKHꢀSURGXFWꢀDQGꢀWKHꢀUHFHLYHUꢁ
ꢀ&RQQHFWꢀWKHꢀSURGXFWꢀLQWRꢀDQꢀRXWOHWꢀRQꢀDꢀFLUFXLWꢀGLIIHUHQWꢀIURPꢀWKDWꢀWRꢀZKLFKꢀWKHꢀ
receiver is connected.
ꢀ&RQVXOWꢀWKHꢀGHDOHUꢀRUꢀDQꢀH[SHULHQFHGꢀUDGLRꢌ79ꢀWHFKQLFLDQꢀIRUꢀKHOSꢁ
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)
This digital apparatus does not exceed the Class B limits for radio noise emissions
from digital apparatus as set out in the interference-causing equipment standard entitled
³'LJLWDOꢀ$SSDUDWXV´ꢃꢀ,&(6ꢉꢊꢊꢍꢀRIꢀWKHꢀ&DQDGLDQꢀ'HSDUWPHQWꢀRIꢀ&RPPXQLFDWLRQVꢁ
Cet appareil numérique respecte les limites de bruits radioeléctriques applicables aux
appareils numériques de Clase B prescrites dans la norme sur le materiel brouilleur:
³$SSDUHLOVꢀ1XPpULTXHV´ꢃꢀ,&(6ꢉꢊꢊꢍꢀpGLFWpHꢀSDUꢀOHꢀPLQLVWHUꢀGHVꢀFRPPXQLFDWLRQVꢁ
&KDQJHVꢀRUꢀPRGL¿FDWLRQVꢀQRWꢀH[SUHVVO\ꢀDSSURYHGꢀE\ꢀWKHꢀSDUW\ꢀUHVSRQVLEOHꢀIRUꢀ
compliance could void the user’s authority to operate the equipment.
Download from Www.Somanuals.co2m7. All Manuals Search And Download.
LIMITED WARRANTY
Your BP652 IntelliSense® Automatic Wrist Blood Pressure Monitor, excluding
the wrist cuff and batteries, is warranted to be free from defects in materials and
workmanship appearing within 5 years from the date of purchase, when used in
accordance with the instructions provided with the monitor. The above warranties
extend only to the original retail purchaser.
We will, at our option, repair or replace without charge any monitor or wrist cuff
covered by the above warranties. Repair or replacement is our only responsibility and
your only remedy under the above warranties.
To obtain warranty service contact Customer Service by calling 1-800-634-4350 for the
address of the repair location and the return shipping and handling fee.
Enclose the Proof of Purchase. Include a letter, with your name, address, phone
QXPEHUꢃꢀDQGꢀGHVFULSWLRQꢀRIꢀWKHꢀVSHFL¿FꢀSUREOHPꢁꢀ3DFNꢀWKHꢀSURGXFWꢀFDUHIXOO\ꢀWRꢀSUHYHQWꢀ
damage in transit. Because of possible loss in transit, we recommend insuring the
product with return receipt requested.
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN
CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMS
ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS
THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION
TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY.
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER
SPECIAL, INCIDENTAL, CONSEQUENTAIL OR INDIRECT COSTS,
EXPENSES OR DAMAGES.
7KLVꢀZDUUDQW\ꢀSURYLGHVꢀ\RXꢀZLWKꢀVSHFL¿FꢀOHJDOꢀULJKWVꢃꢀDQGꢀ\RXꢀPD\ꢀKDYHꢀRWKHUꢀULJKWVꢀ
that vary by jurisdiction. Because of special local requirements, some of the above
limitations and exclusions may not apply to you.
FOR CUSTOMER SERVICE
Visit our web site at:
Call toll free:
1-800-634-4350
Download from Www.Somanuals.com. All Manuals Search And Download.
28
SPECIFICATIONS
BP652 (HEM-6052-Z)
Model:
LCD Digital Display
Display:
Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min.
Measurement Range:
Accuracy/Calibration:
Pressure: ±3mmHg or 2% of reading
Pulse: ±5% of reading
Automatic by electric pump
Inflation:
Automatic pressure release valve
Automatic exhaust valve
Deflation:
Rapid Air Release:
Measurement Method:
Power Source:
Battery Life:
Oscillometric method
ꢄꢁꢅ9ꢀꢂꢀ³$$$´ꢀEDWWHULHV
Approx. 300 uses with 2 new alkaline batteries
50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH
Operating Temperature
/Humidity:
-4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH
700-1060 hPa
Storage Temperature /
Humidity/Air Pressure:
Approximately 4 oz. (114g)
not including batteries
Main Unit Weight:
$SSUR[ꢁꢀꢂꢀꢍꢌꢏ´ꢇOꢈꢀîꢀꢂꢀꢍꢌꢏ´ꢇZꢈꢀîꢀꢐꢌꢑ´ꢀꢇKꢈ
Main Unit Dimensions:
ꢇꢐꢊꢀPPꢀîꢀꢐꢊꢀPPꢀîꢀꢂꢄꢀPPꢈꢀꢇQRWꢀLQFOXGLQJꢀWKHꢀZULVWꢀFXIIꢈ
$SSUR[LPDWHO\ꢀꢅꢀꢄꢌꢏ´ꢀWRꢀꢑꢀꢄꢌꢂ´ꢀꢇꢄꢍꢁꢅꢀWRꢀꢂꢄꢁꢅꢀFPꢈ
Measurable circumfer-
ence of wrist:
Up to 100 readings per user
Memory:
Contents:
0DLQꢀ8QLWꢃꢀ6WRUDJHꢀ&DVHꢃꢀꢂꢀ³$$$´ꢀ$ONDOLQHꢀ%DWWHULHVꢃꢀ
,QVWUXFWLRQꢀ0DQXDOꢃꢀDQGꢀ4XLFNꢀ6WDUWꢀ*XLGH
127(ꢀꢁ7KHVHꢁVSHFL¿FDWLRQVꢁDUHꢁVXEMHFWꢁWRꢁFKDQJHꢁZLWKRXWꢁQRWLFHꢂ
Download from Www.Somanuals.co2m9. All Manuals Search And Download.
Omron Healthcare, Inc.
1200 Lakeside Drive
Bannockburn, IL 60015
Copyright © 2010 Omron Healthcare, Inc.
Made in China
5329415-9A