Omron Fan ZJ FA20 User Manual

Ionizer  
Basic Fan Type  
ZJ-FA20  
High-speed, High cost performance  
Ionization  
Download from Www.Somanuals.com. All Manuals Search And Download.  
in Fan Ionizers  
High-speed Ionization  
A Unique Structure Provides a Uniform Airflow  
The newly developed airflow control system (AFCS) structure optimally controls the airflow of the fan  
to efficiently carry the discharged ions to the target workpiece. This gives the ZJ-FA20 the highest  
ionization performance in its class.  
Even with the airflow at a low setting, ionization is completed in approximately 2 seconds. Small, light  
workpieces are not blown away by the airflow, and static electricity is effectively neutralized.  
Airflow Control System (AFCS)  
Conventional  
ZJ-FA20  
The front louvers and  
internal structure keep  
the airflow uniform.  
The airflow is dispersed,  
lowering efficiency.  
Engineering Data  
Airflow vs. Ionization Time  
Ionization Area vs. Ionization Time  
3
300  
4 s  
3 s  
Adjustment  
dial setting  
2 s  
2.5  
200  
1 s  
MIN:1  
ZJ-FA20  
2
100  
0
2
3
1.5  
1
4
MAX: 5  
-100  
-200  
-300  
0.5  
0
0.5  
0.8  
1.0  
1.3  
Airflow (m/s)  
1.5  
1.8  
2.0  
0
200  
400  
600  
800  
(mm)  
(mm)  
Distance direction  
Measurement Conditions  
Installation distance: 300 mm  
Measurement Conditions  
Airflow: Max.  
Ionization time: ±1,000 V to ±100 V  
Plate monitor: 150 X 150 mm, 20 pF  
Ionization time: ±1,000 V to ±100 V  
Plate monitor: 150 X 150 mm, 20 pF  
Download from Www.Somanuals.com. All Manuals Search And Download.  
rd in Fan Ionizers  
More Versatile Use  
Long-term Ionization Performance  
A built-in ion balance sensor constantly senses the ion condition, and a  
variable DC system maintains the optimal ion balance at all times. This  
provides a long-term, stable balance for reliable ionization.  
Discharge Voltage  
+ Positive  
Variable DC System  
discharge  
voltage  
Ion  
balance  
sensor  
Time  
Time  
0 V  
0 V  
Senses the ion balance  
- Negative  
discharge  
voltage  
Increase  
The ion balance is sensed and the voltage applied to the discharger  
electrodes is varied to adjust the ion output.  
Clean and Easy Maintenance  
The ZJ-FA20 features a fully opening front cover.  
Removing it allows neat and thorough cleaning,  
without spreading dust and other particles around.  
The discharger electrodes can also be replaced for  
long-term operation. LED lamps show the  
ion-generating condition and indicate when  
cleaning is required.  
Cleaning  
the discharger  
electrodes  
Replacing  
the discharger  
electrodes  
Easy-to-see lamps  
A Variety of Installation Possibilities  
In addition to table-top or bench-top installation, the ZJ-FA20 can be easily  
mounted to an aluminum pipe. The angle can also be freely adjusted using the  
angle-adjustment knob and oblong stand.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ordering Information  
Ionizer  
Accessories (sold separafely)  
Model  
Model  
Replacement Filter  
ZJ9-FL120N1 (set of 10)  
ZJ9-NDT06FN1 (set of 6)  
ZJ-FA20  
Replacement Discharger Electrode  
Ratings and Specifications  
AC Adapter (Provided: UIA336-24-JR01A-998 by UNIFIVE CO., LTD.)  
Ionizer  
Item  
Model  
ZJ-FA20  
Item  
100 to 240 VAC, 50/60 Hz  
AC240V: 115VA MAX  
240 VAC: 115 VA max.  
24 VDC  
Power supply voltage  
Current consumption  
Discharge voltage  
24 VDC (See note 1.)  
Input voltage  
900 mA max. (input from included AC adapter)  
Power consumption  
7 kV  
Variable DC  
Discharge method  
Output voltage  
Output current  
Ambient temperature range  
Ambient humidity range  
Weight  
Airflow (m3/min.)  
1.4 to 2.3 m3/min (typical)  
1.5 A max.  
0 to 40°C  
Ionization time (See note 2.)  
Ion balance (See note 2.)  
Amount of generated ozone  
1.2 s (0.8 s with no Filter)  
35% to 85% (with no condensation)  
Approx. 175 g (excluding power cable)  
43.8 X 28 X 95.9 (W X D X H) mm  
10 V max.  
0.01 ppm max. (measured at a distance of 50 mm from air outlet)  
Dimensions  
High-voltage output lamp: ION (yellow),  
Cleaning lamp: CLEANING (orange), Power lamp: POWER (green)  
Indicators  
*
If an additional AC adapter is required, please contact your OMRON  
sales representative  
Automatic ion balance adjustment, airflow adjustment,  
manual ion balance adjustment  
Main functions  
Ambient temperature range  
Ambient humidity range  
Weight (packed state)  
Materials  
Operating and storage: 0 to 50°C (with no icing or condensation)  
Operating: 35% to 65%, storage: 35% to 85% (with no condensation)  
Approx. 2.0 kg  
Unit: ABS, Discharger: Tungsten, stand: SPCC  
Instruction sheet, AC adapter, warning labels (2 types),  
FG connection cable (2 m)  
Accessories  
Note 1: Be sure to use the included AC adapter for Ionizer operation.  
Note 2: Typical default settings.  
Measurement location and conditions: Center of air outlet at a distance of 300 mm, with maximum fan speed  
Ionization time: The time required to lower the charge from 1,000 V to 100 V  
Ion balance measurement time: 10 s  
Dimensions  
(Unit: mm)  
197.5  
140  
8.5  
80  
12  
Mounting Hole Dimensions  
120°  
50 0.2  
15 0.2  
100 0.2  
165  
80  
Rotation Range  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4HIS DOCUMENT PROVIDES INFORMATION MAINLY FOR SELECTING SUITABLE MODELSꢀ 0LEASE READ THE )NSTRUCTION 3HEET CAREFULLY FOR INFORMATION THAT THE  
USER MUST UNDERSTAND AND ACCEPT BEFORE PURCHASEꢁ INCLUDING INFORMATION ON WARRANTYꢁ LIMITATIONS OF LIABILITYꢁ AND PRECAUTIONSꢀ  
/-2/. %,%#42/.)#3 ,,#  
/NE #OMMERCE $RIVE 3CHAUMBURGꢁ  
), ꢏꢃꢇꢊꢌꢆꢄꢌꢃꢍ 5ꢀ3ꢀ!ꢀ  
/-2/. #ORPORATION  
!UTHORIZED $ISTRIBUTORꢀ  
)NDUSTRIAL !UTOMATION #OMPANY  
3ENSING $EVICES $IVISION (ꢁ1ꢁ  
!PPLICATION 3ENSORS $IVISION  
3HIOKOJI (ORIKAWAꢁ 3HIMOGYOꢆKUꢁ  
+YOTOꢁ ꢏꢃꢃꢆꢅꢄꢌꢃ *APAN  
4ELꢂ ꢈꢇ ꢅꢉꢊꢆꢅꢉꢌꢆꢊꢋꢃꢃꢎ&AXꢂ ꢈꢇ ꢅꢉꢊꢆꢅꢉꢌꢆꢊꢊꢅꢊ  
/-2/. !3)! 0!#)&)# 04%ꢁ ,4$ꢁ  
.Oꢀ ꢉꢌꢅ! !LEXANDRA 2OAD ꢐ ꢃꢄꢆꢃꢄꢎꢃꢅ ꢈ,OBBY ꢍ ꢁ  
!LEXANDRA 4ECHNOPARKꢁ 3INGAPORE ꢇꢇꢋꢋꢏꢊ  
4ELꢂ ꢈꢏꢄ ꢏꢅꢌꢄꢆꢌꢃꢇꢇꢎ&AXꢂ ꢈꢏꢄ ꢏꢅꢌꢄꢆꢍꢊꢇꢇ  
4ELꢂ ꢈꢅꢇ ꢊꢄꢆꢌꢉꢉꢆꢊꢃꢏꢅꢎ&AXꢂ ꢈꢅꢇ ꢊꢄꢆꢌꢉꢉꢆꢊꢇꢃꢊ  
2EGIONAL (EADQUARTERS  
/-2/. %52/0% "ꢁ6ꢁ  
3ENSOR "USINESS 5NIT  
#ARLꢆ"ENZꢆ3TRꢀ ꢉꢁ $ꢆꢊꢇꢇꢄꢉ .UFRINGENꢁ  
'ERMANY  
4ELꢂ ꢈꢉꢋ ꢊꢃꢌꢍꢆꢅꢇꢇꢆꢃꢎ&AXꢂ ꢈꢉꢋ ꢊꢃꢌꢍꢆꢅꢇꢇꢆꢇꢋꢋ  
/-2/. ꢇ#().! #/ꢁꢈ ,4$ꢁ  
2OOM ꢍꢍꢇꢇꢁ "ANK OF #HINA 4OWERꢁ  
ꢍꢃꢃ 9IN #HENG :HONG 2OADꢁ  
0U$ONG .EW !REAꢁ 3HANGHAIꢁ ꢍꢃꢃꢇꢍꢃꢁ #HINA  
4ELꢂ ꢈꢅꢏ ꢍꢇꢆꢄꢃꢌꢊꢆꢍꢍꢍꢍꢎ&AXꢂ ꢈꢅꢏ ꢍꢇꢆꢄꢃꢌꢊꢆꢍꢍꢃꢃ  
Ú /-2/. #ORPORATION ꢍꢃꢃꢅ !LL 2IGHTS 2ESERVEDꢀ  
)N THE INTEREST OF PRODUCT IMPROVEMENTꢁ  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICEꢀ  
CSM_1_1_0409  
0RINTED IN *APAN  
/-2/. )NDUSTRIAL !UTOMATION 'LOBALꢂ WWWꢁIAꢁOMRONꢁCOM  
#ATꢁ .Oꢁ %ꢂꢃꢄꢅ%ꢄꢅꢆꢄ  
ꢃꢄꢃꢅꢆꢃꢀꢇ- ꢈꢃꢄꢃꢅ ꢈ#  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Milwaukee Saw 2620 20 User Manual
Multiquip Portable Generator DCA 220SSVU User Manual
Nintendo Video Games 45496902612 User Manual
NuTone Automobile Parts 834 User Manual
Oceanic Scuba Diving Equipment 04892916 User Manual
Olympus Printer P S100 User Manual
Oregon Clock JM889NA User Manual
Orion Car Audio Stereo Amplifier 8004 2 User Manual
Panasonic Car Stereo System CQ C3401 User Manual
Panasonic CRT Television CT 20G12 User Manual